Optomicrofluidic measurement of particle-encapsulated droplet system

Abstract

Droplet microfluidics combined with optical detection has become a powerful approach for high-throughput single-cell assays, but these systems often face limited sensitivity and signal heterogeneity due to optical and geometrical constraints. We investigate how key operating parameters influence the performance of a droplet-based optomicrofluidic platform. Experiments examine optical interactions between guided light and aqueous droplets containing fluorescent (FL) particles flowing in oil. Geometrical optics simulations model light-droplet interactions, while FL simulations quantify signal variations caused by particle size and position. Two refracted signals are observed experimentally: a droplet-refracted signal (DRS) that scales with droplet diameter and a particle-refracted signal (PRS) produced by light interaction with encapsulated particles. Both experiments and simulations show that PRS becomes prominent when the particle-to-droplet size ratio Dp∗D^*_\text{p} lies between 0.23-0.33, enabling label-free detection. Particles near the droplet center (rp∗<0.4r^*_\text{p} < 0.4) display reduced angular dependence and more uniform FL signals. Simulations further show that FL intensity increases with Dp∗D^*_\text{p}, rising sharply from 0.33 to 0.5 and more gradually up to 0.66. Additionally, reducing the oil layer thickness enhances fluorescence by minimizing optical losses at the droplet-channel interface. These results demonstrate that controlling Dp∗D^*_\text{p}, particle position, and oil layer thickness improves FL strength and uniformity, providing a framework for optimizing droplet-based fluorescence detection in microflow cytometry and single-cell assays.

Introduction

Droplet microfluidics has emerged as a powerful platform for high-throughput biochemical screening, enabling the generation of monodisperse droplets ranging from picoliters to microliters at rates up to several MHz, while minimizing sample and reagent consumption [1, 2, 3, 4, 5]. Each droplet functions as an independent microreactor, allowing precise control, scalability, and prevention of cross-contamination [6, 7]. Accurate analysis of droplet contents is essential, and optical detection techniques are particularly attractive due to their non-invasive, real-time, and high-throughput capabilities [8, 9]. While flow cytometry remains the benchmark for single-cell analysis in clinical diagnostics [10], the integration of droplet microfluidics with optical detection expands its applicability to areas such as single-cell profiling, sequencing, drug discovery, and pathogen detection [11]. Nevertheless, conventional optofluidic setups often rely on bulky and expensive instrumentation, requiring precise alignment and technical expertise, which poses barriers to widespread adoption in standard laboratory settings [12].

To overcome these challenges, optomicrofluidic systems integrate optical fibers into microfluidic chips, creating simplified, flexible, and cost-effective setups [13]. These fibers serve as light guides and enable excitation and collection of fluorescence, absorbance, and scattered light signals. The time-shift technique measures temporal delays in scattered light and facilitates precise analysis of particle size, velocity, and refractive index [14]. Efforts to enhance optomicrofluidic system performance include various modifications: integrating microlenses [15, 16], collimators, multi-level chip designs, and channel dimension adjustments [17], optical fibers with varied numerical apertures and lensed fibers [18]. Similarly, focused forward scattering signals have demonstrated enhanced detection by altering the refractive indices of the droplet and the medium [19, 20].

Accurate measurements of optical signals are critical to the success of optomicrofluidic detection, directly impacting the sensitivity, specificity, and reliability of droplet-based biochemical assays [21, 22, 23, 24, 25]. However, system-induced variations in optical signals can significantly compromise measurement accuracy. In a recent study, five distinct microparticle populations, each labeled with increasing concentrations of fluorophore, exhibited substantial standard deviations in fluorescence intensity within an optofluidic platform [6], highlighting pronounced signal variations even among well-defined populations. Despite its critical impact on assay fidelity, fluorescence intensity variation in particle-encapsulated droplets within fiber-integrated microfluidic systems remains largely unaddressed.

The interaction of light with drop-encapsulated microparticles involves complex scattering, absorption, and refraction phenomena, which are not yet fully understood. Addressing these optical complexities is vital for improving the accuracy and sensitivity of fluorescence-based detection, particularly in applications requiring high-fidelity single-particle analyses. In particular, the fluorescence collection efficiency is influenced by the droplet curvature[26], which affects light absorption, scattering, and refraction, thereby altering the spatial intensity distribution of the emitted signal. A deeper understanding of system parameters, such as the particle-to-droplet size ratio, particle position within the droplet, and particle angular orientation relative to the optical axis, is essential for improving fluorescence detection in fiber-integrated droplet microfluidic platforms. Such insights will be key to advancing optomicrofluidic measurements targeting quantitative studies on cellular heterogeneity.

In this work, we investigate how operating parameters influence the performance of a droplet based optomicrofluidic system using both experiments and simulations. Experimentally, we generate particle encapsulated droplets and measure optical signals, including droplet refracted and particle reflected or scattered signals, along with fluorescence emission, using fiber integrated detection. Complementing these measurements, simulations based on geometrical optics and fluorescence modeling quantify light droplet interactions and signal variation. We systematically examine the effects of droplet size, particle to droplet size ratio, particle position, including angular orientation and oil layer thickness on fluorescence signal characteristics. This framework supports the design of improved optomicrofluidic systems for microflow cytometry and single cell analysis.

Experimental details

Device Geometry

The optomicrofluidic device comprises two main regions: a droplet encapsulation region with a flow-focusing geometry and an optical detection region (Figure 1a). The microchannel has a depth of 130 μm130\ \mu\mathrm{m} throughout, narrowing to 30 μm30\ \mu\mathrm{m} at the throat for droplet generation and expanding to 100 μm100\ \mu\mathrm{m} in the main channel (Figure 1b). A photograph of the device is shown in Figure 1c. The detection region includes three grooves (I–III) to hold standard optical fibers (OD 125 μm125\ \mu\mathrm{m}). Each groove is 130 μm130\ \mu\mathrm{m} wide and deep, placed 100 μm100\ \mu\mathrm{m} from the fluid channel wall. Groove I (α=0∘\alpha= 0^{\circ}) holds the excitation fiber. Groove II (α=45∘\alpha= 45^{\circ}) collects side-scattered signals, and Groove III (α=135∘\alpha= 135^{\circ}) collects fluorescence signals. Fabrication involves standard photolithography to create a silicon master, followed by PDMS soft lithography using molding and bonding. Additional fabrication details are available elsewhere [27].

Schematic of the optomicrofluidic experimental setup, flow focusing junction, and optomicrofluidic device

Figure 1. (a) Schematic of the optomicrofluidic experimental setup showing the droplet encapsulation and optical detection regions, (b) Experimental image of the flow focusing junction used for droplet generation, (c) Photograph of the optomicrofluidic device with the excitation and collection fibers.

Materials

Fluorescent microparticles (15 μm15\ \mu\mathrm{m}, microParticles GmbH, Germany) are suspended in deionized water (resistivity: 18.2 MΩ⋅cm18.2\ \mathrm{M}\Omega\cdot\mathrm{cm}, ELGA, UK) with 5%5\% Pluronic F127 (Sigma-Aldrich, India) to prevent agglomeration. The suspension is washed twice and sonicated for 5 minutes using an ultrasonic cleaner (Maxsell, India). The continuous phase is mineral oil (Sigma-Aldrich, India) with 5% (wt/wt) Span 85 added for droplet stability and filtered using 0.2 μ\mum PTFE filters to remove unwanted particles.

Experimental Setup

The experimental setup is shown in Figure 1a; see the Supplementary Material [28] for photograph. Experiments are performed on an inverted microscope (IX73, Olympus Inc., Germany) with a high-speed camera (Phantom v2640, Vision Research Inc., USA). The microparticle suspension and mineral oil are infused using syringe pumps (neMESYS, Cetoni, Germany) via polyethylene tubing (BTPE-50, Instech Laboratories, USA). Single-mode (9 μ\mum core) and multimode (62.5 μ\mum core) optical fibers are stripped, cleaved flat, and inserted into the grooves filled with index-matching fluid (Fiber Instruments Sales Inc., USA). A 532 nm fiber-coupled laser (Wave Form Systems, USA) operating at 1 mW excites the droplets via the single-mode fiber. Multimode fibers placed at 45° and 135° collect side-scattered and fluorescence signals, respectively. Signals are directed to a Si photodiode (DET02AFC/M, Thorlabs) and a photomultiplier tube (PMT2101/M, Thorlabs), with a 575/50 nm bandpass filter (Chroma Technology, USA) for fluorescence. Data acquisition is handled by STEMlab 125-10 kit (RedPitaya, Europe).

Data Processing and Video Analysis

Voltage signals from the photodiode (PD) and Photomultiplier tube (PMT) are acquired by RedPitaya at a fixed sampling rate based on flow conditions and recorded as CSV files using Jupyter Notebook. Time-series data are analyzed in Python to determine peak height (SdrS_{\mathrm{dr}}), width at 90% (tdrt_{\mathrm{dr}}), inter-peak distance, and frequency (fdrf_{\mathrm{dr}}) for droplet-refracted signals. Fluorescence peaks (SflS_{\mathrm{fl}}) are similarly extracted. Based on fluorescence signal images, incomplete peaks resulting from limitation in data acquisition with STEMlab 125-10, are excluded. Videos are processed in ImageJ to measure droplet diameter and particle position. The centroid of each droplet and encapsulated particle is identified in the frame prior to light interaction. The distance (rpr_{\mathrm{p}}) and angle (θp\theta_{\mathrm{p}}) between the droplet and particle centroids are computed as shown in

Numerical Model

Light–Droplet Interaction

Light interaction with droplets plays a vital role in optomicrofluidic detection systems [29]. When the droplet diameter (DdD_{\mathrm{d}}) is much larger than the excitation wavelength (λ\lambda), i.e., Dd≫λD_{\mathrm{d}} \gg\lambda, geometric optics is applicable, and scattering is predominantly governed by geometric effects [30]. The size parameter α=πDd/λ\alpha= \pi D_{\mathrm{d}}/\lambda characterizes this regime, with α≫1\alpha\gg1 indicating dominance of geometric scattering. Under these conditions, the droplet behaves like a spherical object that reflects and refracts light in multiple directions, while diffraction effects remain minimal [31]. Light propagation is governed by Snell’s law [32].

Simulations are conducted using the Ray Optics module in COMSOL Multiphysics 6.1 [33]. For inhomogeneous media, ray propagation is described by:

dqdt=kn,dkdt=−∇n(q)(1)\frac{d q}{d t}=\frac{k}{n}, \qquad\frac{d k}{d t}=-\nabla n(q) \tag*{(1)}

where qq is the position vector and kk the wave vector, and nn denotes the refractive index of the medium [34]. Although Eq. (1) is written in a general form applicable to inhomogeneous media, in the present simulations each material domain is treated as optically homogeneous, with a constant refractive index assigned within that domain. During ray propagation, the refractive index is updated when a ray crosses an interface between different materials, and refraction is computed using Snell’s law to ensure phase continuity.

The simulation geometry of the optomicrofluidic device, described in § 2.1, is illustrated in Figure 2(a). Rays released from hexapolar grid within the core of a single-mode fiber (SMF), as shown in Figure 2(b). The excitation beam’s spot radius at the channel center, in the absence of droplets, is estimated to be 7.82 μ\mum (Figure 2(c)) using ray optics simulation and corresponding intensity profile as a function of radius is shown in Figure 2(d). The simulation computes ray intensities using Stokes parameters to account for polarization [35]. "Freeze wall" boundaries accumulate incident intensities normalized by surface area. Secondary rays from internal reflections are managed using intensity thresholds and release limits for computational efficiency. Output rays collected at multimode fibers placed at 45° and 315° represent droplet-refracted signals. Parametric sweep over the droplet position (denoted by offset gog_{\mathrm{o}}, as marked in Figure 2a) enables dynamic modeling of light-droplet interaction during droplet transit through the detection region.

Model geometry, hexapolar grid, excitation beam profile, and Gaussian fit

Figure 2. (a) Model geometry of the optomicrofluidic device with a droplet, fluid channel, and excitation/collection optical fibers used for the numerical simulations, (b) Model showing the positions of ray release from a hexapolar grid within the core of a singlemode fiber (SMF), (c) Geometry of the excitation beam profile which is measured to be 7.82 μ\mum, (d). Excitation profile plotted across the optical beam, fit to a Gaussian f(x)=0.78e−r2/(2σ2)f(x) = 0.78e^{-r^2/(2\sigma^2)} where σ=3.49\sigma= 3.49 with R2=0.88R^2 = 0.88.

Fluorescence Simulation

Fluorescence occurs when fluorophores absorb excitation light and emit light at longer wavelengths [36]. In droplet-based systems, multiple light interactions—absorption, scattering, and internal reflection—affect fluorescence behavior [37, 38]. Enhancing signal strength and uniformity is critical for high-throughput screening and single-cell studies [19, 39].

A two-step computational approach is implemented using COMSOL [40, 41]. First, ray tracing simulations calculate the excitation light reaching the particle surface. Second, in COMSOL fluorescence emission is modeled using the Helmholtz diffusion equation:

∇(−c∇u)+au=f(2)\nabla(-c\nabla u) + au = f \tag*{(2)}

with parameters,

u=ϕu = \phi
c=D=13(μa+μs′)c = D = \frac{1}{3(\mu_a+\mu_s')}
a=μaa = \mu_a
f=Sf = S

where uu is the fluorescence intensity, DD is the optical diffusion coefficient, μa\mu_a and μs′\mu_s' are absorption coefficient and reduced scattering coefficient at emission wavelengths, respectively, and SS is the local excitation intensity which is computed from ray optics simulation. μa\mu_a and μs′\mu_s' for PDMS, mineral oil and water were taken from the literature [42, 43, 44, 45, 46, 47, 48, 49]; The corresponding values are provided in the Supplementary Material [28].

Fluorescence output is computed by integrating the emission over the MMF core area at 135°, providing the simulated fluorescence intensity. Particle scattering is also modeled using a point source at the particle center emitting isotropically. The scattered light collected at MMFs is weighted by the surface excitation profile to determine the particle’s refracted signal. This integrated model enables realistic simulation of fluorescence and refracted signals in droplet-based optomicrofluidic systems.

Results and Discussion

Effect of droplet size on droplet and particle refracted signals

Water-in-oil droplets are formed by infusing DI water, containing 0.1% Tween 20, 15% Optiprep, and 3×1053 \times10^{5} ml−1^{-1} of 15 μ\mum pluronic-treated microparticles, as the dispersed phase, and mineral oil with 5% Span 85 as the continuous phase. Droplet size is controlled by varying the continuous phase flow rate (QcQ_{\mathrm{c}}) while maintaining a constant Qd=0.3Q_{\mathrm{d}} = 0.3 μ\mul/min, dispersed phase flow rate. Images of droplets at different flow rate ratios (Qr=Qc/QdQ_{\mathrm{r}} = Q_{\mathrm{c}}/Q_{\mathrm{d}}) are shown in Figure 3(a). As QrQ_{\mathrm{r}} increases, droplet diameter (DdD_{\mathrm{d}}) decreases, with a minimum stable size of 48 μ\mum (see the Supplementary Material [28]).

Images of droplets, droplet refracted signals, correlation plot, and simulation studies

Figure 3. (a) Images of the droplets generated at varying QrQ_{\mathrm{r}}, (b) corresponding droplet refracted signal acquired. The dashed line indicates missing data due to real-time data acquisition limitations, (c) Correlation plot for droplet refracted signal height with droplet diameter. Inset: Oil layer thickness decreases with increasing droplet diameter. Error bars indicate ±\pmSD. (d) Simulation studies show the particle-refracted signal increases with increasing Dp∗D_{\mathrm{p}}^{*}, i.e., smaller droplet size at θp=90∘\theta_{\mathrm{p}} = 90^{\circ} with fixed particle diameter of 15 μ\mum and a fixed 1.5 μ\mum gap between the particle surface and the droplet boundary.

When a particle-laden droplet enters the optical region, the laser beam is reflected and refracted, producing signals that encode droplet size and generation rate. Light is collected by a multimode fiber (MMF) at α=45∘\alpha= 45^{\circ} (Figure 1a, 1c, and Supplementary Material [28]). A high-speed camera captures droplet formation, while a STEMlab 125-10 system records the droplet-refracted signal (DRS). Representative DRS waveforms for different QrQ_{\mathrm{r}} values are shown in Figure 3(b). Key DRS features, peak height (SdrS_{\mathrm{dr}}), peak width (tdrt_{\mathrm{dr}}) at 90% of peak height, and droplet generation rate (fdrf_{\mathrm{dr}}), are extracted. Peak height (SdrS_{\mathrm{dr}}), influenced by droplet size, is the most reliable sizing metric, as tdrt_{\mathrm{dr}} depends on excitation beam width and continuous phase velocity (UcU_{\mathrm{c}}), limiting its utility [14]. Plots of SdrS_{\mathrm{dr}} and tdrt_{\mathrm{dr}} versus DdD_{\mathrm{d}} are shown in Figure 3(c) and see the Supplementary Material [28]. Both metrics decrease as DdD_{\mathrm{d}} reduces with increasing QrQ_{\mathrm{r}}. In Figure 3(c), SdrS_{\mathrm{dr}} exhibits two regimes: in the large-droplet regime (Dd>85D_{\mathrm{d}} > 85 μ\mum), it decreases gradually with droplet size, whereas in the small-droplet regime (Dd<85D_{\mathrm{d}} < 85 μ\mum), it decreases at a higher rate. Analysis of Covariance (ANCOVA) reveals a statistically significant (p = 0.024) difference in the droplet-size-dependent slopes of peak height between the two regimes. Larger droplets deform against channel walls, while smaller droplets retain a near-spherical shape. This shift in morphology affects optical behavior. In large droplets, oil layer thickness, to=(Wc−Dd)/2t_{\mathrm{o}} = (W_{\mathrm{c}}-D_{\mathrm{d}})/2, where WcW_{\mathrm{c}} is the channel width and DdD_{\mathrm{d}} is the diameter of droplet, increases gradually. In small droplets, tot_{\mathrm{o}} increases sharply (Figure 3(c) inset), altering light paths and enhancing scattering into the oil. As a result, signal intensity falls, highlighting sensitivity to droplet shape and confinement.

A secondary peak, termed the particle-refracted signal (PRS), detected alongside the droplet-refracted signal (DRS) as it approaches the MMF at α=45∘\alpha= 45^{\circ}. The PRS originates from light refracted and scattered by encapsulated particles, and its peak amplitude (SprS_{\mathrm{pr}}) becomes more prominent with smaller droplets (Figure 3b). To understand this behavior, simulations were conducted to analyze the influence of droplet size on PRS intensity while keeping the particle size fixed. These simulations focused on the optical response at the particle location, allowing isolation of scattering effects due to spatial confinement. Figure 3(d) shows the simulation results for a constant particle size, Dp=15 μmD_p=15\ \mu\mathrm{m} and decreasing droplet size. The refracted signal intensity collected at the particle position increases with the particle-to-droplet size ratio, Dp∗=Dp/DdD_p^*=D_p/D_d. This trend highlights enhanced light confinement and scattering efficiency as the particle occupies a larger relative volume within smaller droplets. These findings support the observed increase in PRS with decreasing droplet size in experimental studies. One question arises: how do these optical responses, arising from light–droplet interactions, change with droplet position along the channel relative to the optical beam path? To further investigate light–droplet interactions, we perform numerical simulations in the following section.

Modeling the impact of droplet size on refracted signal

Numerical simulations are performed using the Ray Optics module in COMSOL Multiphysics 6.1 [33], with material refractive indices defined accordingly. The model, as outlined in § 3.1, evaluates the optical signal characteristics as a function of droplet size and axial position. To improve signal capture, a second multimode fiber (MMF) is introduced at α=315∘\alpha= 315^\circ, complementing the primary MMF at α=45∘\alpha= 45^\circ. The excitation beam’s spot radius at the channel center, in the absence of droplets, is estimated to be 7.82 μm7.82\ \mu\mathrm{m} (Figure 2(c)) using ray optics simulation. To assess signal variation due to droplet position, the axial offset between the droplet center and beam center (gog_o) is varied in 5 μm5\ \mu\mathrm{m} increments.

Figure 4(a) shows ray trajectories at different gog_o values for a droplet diameter of 80 μm80\ \mu\mathrm{m}. At go=−50 μmg_o=-50\ \mu\mathrm{m} (Figure 4(a)-Figure 4i), the droplet begins to intersect the beam path, resulting in strong refraction toward the α=45∘\alpha=45^\circ MMF. At go=0 μmg_o=0\ \mu\mathrm{m} (Figure 4(a)-ii), the beam passes perpendicularly through the droplet, creating two distinct reflection zones at the fluid–PDMS interfaces. As the droplet exits the optical region at go=50 μmg_o=50\ \mu\mathrm{m} (Figure 4(a)-iii), refraction is directed toward the α=315∘\alpha=315^\circ MMF. This leads to two signal peaks: a leading peak at 45∘45^\circ as the droplet enters and a lagging peak at 315∘315^\circ as it exits [6]. The separation distance and intensity of these peaks depend on droplet size, refractive index, and velocity [14]. Here, the average accumulated intensity (II), defined as energy per unit time per unit area at the MMF core, is used to quantify this response. Figure 4(b) shows II profiles at both detectors (α=45∘\alpha=45^\circ and 315∘315^\circ) for droplets of varying sizes. Peak intensity increases with droplet size, while the separation between leading and lagging peaks also widens. Since beam width and droplet velocity were held constant in simulations, peak width remained nearly constant (40 μm40\ \mu\mathrm{m}), making peak height a more reliable indicator of droplet size than width.

Comparison of experimental and simulated droplet-refracted signals at varied positions

Figure 4. Comparison of experimental and simulated droplet-refracted signals at varied positions. (a-i) Ray trajectory of the excitation source at droplet position go=−50 μmg_o=-50\ \mu\mathrm{m}, (a-ii) Ray trajectory at go=0 μmg_o=0\ \mu\mathrm{m}, (a-iii) Ray trajectory at go=50 μmg_o=50\ \mu\mathrm{m}, (b) Average accumulated intensity collected at 45° (solid line) and 315° MMF (dash line) for different droplet sizes, (c) Comparison of droplet refracted signals for varying droplet sizes between simulation and experiments. Experimental data points and simulated values exhibit linear and parallel trends indicating consistent scaling behavior. A calibration constant kPD=2.4×107k_{\mathrm{PD}}=2.4\times10^{7} was applied using the relation Sdr=kPDIsimS_{\mathrm{dr}}=k_{\mathrm{PD}}I_{\mathrm{sim}}. The blue line represents a linear fit to the simulated data using the equation y=Ax+By=Ax+B, where A=0.087A=0.087 and B=−4.2B=-4.2. Error bars indicate ±SD\pm\mathrm{SD}.

The numerical model validation is shown in Figure 4(c), comparing simulated peak heights with experimental measurements. Both show a linear correlation between peak height and droplet size, with minimal deviations [50]. These results confirm the accuracy of the ray-optics model in capturing size-dependent optical behavior. While DRS intensity increases with increasing droplet radius, fluorescence collection efficiency is also influenced by encapsulation dynamics. How do droplet encapsulation characteristics influence the excitation and collection of fluorescence? These aspects are explored in detail in the following sections.

Effect of droplet encapsulation on fluorescence signal

Optomicrofluidic detection of droplet-encapsulated microparticles or cells primarily aims to measure variations in particle properties [51], such as heterogeneous surface marker expression [52], by analyzing changes in fluorescence signal. However, variations in fluorescence can also arise from differences in droplet encapsulation parameters, complicating interpretation and limiting the accuracy of applications that require precise quantification or differentiation between similar cell subpopulations. Understanding and minimizing fluorescence signal heterogeneity due to encapsulation effects is therefore critical. To investigate the impact of encapsulation parameters on fluorescence, we analyze experimental fluorescence intensity data from 15 μm15\ \mu\mathrm{m} fluorescent particles encapsulated in droplets of varying sizes.

Experimental images of encapsulated fluorescent particles across a range of droplet sizes (i.e., varying Dp∗D_p^*) and their corresponding droplet refracted and fluorescence signals are shown in Figure 5(a). From 367 DRS files, droplet diameters were obtained using the correlation plot in Figure 3(c). Figure 5(b) shows the variation of normalized fluorescence intensity (Sfl∗S_{\mathrm{fl}}^*) with droplet diameter, where SflS_{\mathrm{fl}} is scaled by the STEMlab 125-10 maximum measurable voltage (20.4 V). A wide spread in fluorescence intensity is observed across the DdD_d and corresponding Dp∗D_p^* range, with no clear trend. This suggests that fluorescence output is not solely dependent on droplet size. Instead, signal heterogeneity likely results from the combined effects of multiple factors such as microparticle size, particle position within the droplet, and oil layer thickness. A detailed understanding of how each parameter contributes is essential to optimize droplet-based optical detection. The following section investigates these individual factors and their influence on fluorescence response.

Effect of droplet size and particle confinement on fluorescence, with panels a–d showing particle-encapsulated droplets and fluorescence signals, normalized fluorescence intensity, simulated versus experimental fluorescence, and simulated fluorescence intensity

Figure 5. Effect of droplet size and particle confinement on fluorescence.(a) Particle encapsulated droplets of varying size and corresponding droplet refracted signal (green) and particle fluorescence signal (red), (b) Normalized fluorescence intensity values for varying particle-to-droplet size ratio, (c) Comparison of simulated and experimental particle fluorescence for different particle configuration (P1-P7). Each data point corresponds to a unique droplet–particle configuration; see the Supplementary Material [28] for DdD_d, rpr_p and θp\theta_p values. A calibration constant kPMT=3.01×10−6k_{\mathrm{PMT}} = 3.01 \times10^{-6} was applied using the relation Sfl,sim=kPMTIfl,simS_{\mathrm{fl,sim}} = k_{\mathrm{PMT}}I_{\mathrm{fl,sim}}, (d) Simulated fluorescence intensity from 135° MMF for varied particle-to-droplet size ratio with particle positioned at θp=90∘\theta_p = 90^\circ with fixed DdD_d of 30 μ\mum.

Effect of particle-to-droplet size ratio on fluorescence signal

The impact of particle-to-droplet size ratio (Dp∗D_p^*) on fluorescence intensity is examined using ray tracing and fluorescence simulations, keeping droplet diameter and particle position constant. Simulations are based on the model described in § 3.2. Model validation, shown in the Figure 5(c), compares simulated and experimental fluorescence across different droplet configurations. See the Supplementary Material [28] for details on particle configuration. Simulations were performed using a fixed droplet diameter of 30 μm30\ \mu\mathrm{m}, varying particle diameter from 10 μm10\ \mu\mathrm{m} to 20 μm20\ \mu\mathrm{m}. The particle is located at θp=90∘\theta_p=90^\circ, near the optical axis (see Figure 5(a) for Dp∗=0.24D_p^*=0.24). As shown in Figure 5(d), increasing the Dp∗D_p^* from 0.33 to 0.66 results in a pronounced enhancement of fluorescence intensity, corresponding to an approximately fivefold increase. This increase is attributed to the larger particle surface area interacting with a greater fraction of the excitation field, leading to enhanced fluorescence generation and collection efficiency.

The results show that fluorescence intensity increases with Dp∗D_p^*, although the rate of increase is not uniform. Between Dp∗=0.33D_p^* = 0.33 and 0.5, the intensity rises sharply, indicating strong size sensitivity in this range, followed by a more gradual increase from 0.5 to 0.66. This behavior suggests diminishing incremental gains in fluorescence for larger particles. Consequently, selecting an appropriate range is important for balancing fluorescence signal strength and size sensitivity. The lower range (Dp∗=0.33D_p^* = 0.33–0.5) offers high sensitivity to particle size, whereas larger Dp∗D_p^* values provide stronger absolute signals with reduced sensitivity to small size variations.

Effect of microparticle position on fluorescence signal

To study the effect of microparticle position on fluorescence signal, we analyze experimental data at a fixed particle-to-droplet size ratio and oil layer thickness. The particle position is described by its radial distance from the droplet center (rpr_p) and angular location (θp\theta_p), measured clockwise from a reference axis (Figure 1(a)). A total of 237 videos were processed to extract rpr_p and θp\theta_p, following the method in § 2.4. Data shown in Figure 6(a) and Figure 6(b) correspond to Dp∗≈0.3D_p^* \approx0.3 (±0.03\pm0.03) and oil layer thickness of 25 µm (±2.5\pm2.5 µm). Figure 6(a) displays representative particle positions across different angular orientations, together with the corresponding droplet-refracted signal (DRS) and fluorescence profiles, and is intended for qualitative illustration of signal features. The particle location notably affects both the timing and magnitude of the particle-refracted signal (PRS) relative to DRS. Figure 6(b) presents the corresponding quantitative analysis, showing fluorescence intensity as a function of dimensionless radial position rp∗=rp/Rdr_p^* = r_p/R_d, here RdR_d is droplet radius. Particle illustrations are shown at half-size for clarity. Fluorescence intensity differs significantly between particles near the droplet center and those closer to the boundary, with a nonparametric Mann–Whitney U test confirming higher fluorescence for rp∗<0.4r_p^* < 0.4 than for rp∗>0.4r_p^* > 0.4 (p<0.05p < 0.05). The fluorescence distributions for the two rp∗r_p^* groups are further illustrated using cumulative distribution function (CDF) plot; see the Supplementary Material [28]. Particles near the center exhibit weak angular dependence, quantified by a coefficient of variation (CV) of approximately 60%, whereas near-boundary particles show stronger angular dependence (CV ≈78%\approx78\%), with enhanced fluorescence near θp=135∘\theta_p = 135^\circ and 270∘270^\circ.

Influence of particle position on fluorescence signal

Figure 6. Influence of particle position on fluorescence signal. (a) Particle encapsulated at different position and corresponding droplet refracted signal (green) and particle fluorescence signal (red), (b) Particle position and fluorescence intensity from experimental data for Dp∗D_p^* between 0.27 to 0.3, (c) Simulation for light intensity reaching particle surface positioned at varied angle (θp\theta_p) for fixed rpr_p (16 µm) and DdD_d (50 µm). (d) Simulated fluorescence intensity reaching 135° MMF for particle positioned at varied angle (θp\theta_p): 0° to 360° in steps of 45°.

Across multiple droplets (Dp∗D_p^*), particles near θp=135∘\theta_p = 135^\circ generally exhibit high fluorescence. However, a consistent trend across droplet sizes is absent, likely due to the lack of depth (z-axis) information in position determination, introducing variability. The enhanced signal near θp=135∘\theta_p = 135^\circ is attributed to more efficient collection by the detection fiber placed at α=135∘\alpha= 135^\circ.

To further probe angular effects, ray optics simulations were conducted at fixed radial distance rp=16 μmr_p = 16\ \mu\mathrm{m} or rp∗=0.64r_p^* = 0.64 for Dp∗=0.3D_p^* = 0.3. The particle was placed in the beam axis plane at constant depth, and θp\theta_p varied in 45∘45^\circ steps. Incident excitation intensity on the particle surface was computed by freezing rays at the interface. Figure 6(c) shows light intensity reaching particle, peaks for (θp)(\theta_p) between 270∘270^\circ and 315∘315^\circ, while the detected fluorescence (Figure 6(d)) peaks near θp=135∘\theta_p = 135^\circ, where the collection fiber is positioned. This discrepancy highlights the critical role of spatial alignment between excitation and detection paths. Simulations for varying droplet diameters are provided in the Supplementary Material [28].

In summary, for Dp∗≈0.3D_p^* \approx0.3 (±0.03\pm0.03), stronger fluorescence is achieved when particles are either at rp∗<0.4r_p^* < 0.4 (any angle) or at rp∗>0.4r_p^* > 0.4 but aligned near the collection fiber at θp=135∘\theta_p = 135^\circ. Fluorescence variability due to angular position is minimal at lower rp∗r_p^*, but increases significantly for particles farther from the center. Thus, maintaining rp∗<0.4r_p^* < 0.4 ensures more consistent fluorescence signals.

Effect of oil layer thickness on fluorescence signal

We used simulations to study the impact of oil layer thickness (tot_o) between the droplet and channel walls on the fluorescence signal, while keeping Dp∗=0.5D_p^* = 0.5 and particle position fixed (rp∗=0.4r_p^* = 0.4). The oil layer thickness was varied by adjusting the channel width WcW_c, with the droplet diameter held constant at 30 μm30\ \mu\mathrm{m}. Figure 7 presents results from two-stage fluorescence simulations, showing the excitation intensity at the particle surface (a), particle scattering intensity (b), and fluorescence intensity (c), arranged in three columns corresponding to different geometric configurations. The left column (to=35 μmt_o = 35\ \mu\mathrm{m}, tp=65 μmt_p = 65\ \mu\mathrm{m} (thickness of PDMS between SM fiber and the fluid channel wall)) represents the baseline configuration with the largest oil layer. The middle column (to=10 μmt_o = 10\ \mu\mathrm{m}, tp=90 μmt_p = 90\ \mu\mathrm{m}) corresponds to a reduced oil layer thickness while keeping the PDMS thickness constant, thereby maintaining a fixed fiber-to-droplet distance. In contrast, the right column (to=10 μmt_o = 10\ \mu\mathrm{m}, tp=65 μmt_p = 65\ \mu\mathrm{m}) represents a reduced oil layer thickness accompanied by a shorter fiber-to-droplet distance.

Simulation of oil-layer thickness effects on fluorescence signals for different geometric configurations

Figure 7. Simulation of oil-layer thickness effects on fluorescence signals for different geometric configurations. The oil-layer thickness (tot_o) was varied by adjusting the channel width while keeping the droplet diameter fixed. Rows show (a) excitation intensity at the particle surface, (b) particle scattering intensity reaching the 135° multimode fiber (MMF), and (c) fluorescence intensity reaching the 135° MMF. The three columns correspond to the baseline geometry, reduced oil-layer thickness with a fixed fiber-to-droplet distance, and reduced oil-layer thickness with a shortened fiber-to-droplet distance, respectively.

Comparing the left and middle columns isolates the effect of oil-layer absorption, showing that reducing tot_o leads to an increase in fluorescence intensity of approximately 20%, despite minimal changes in excitation intensity. This indicates that reduced absorption losses in the oil layer directly contribute to fluorescence enhancement. In contrast, when the reduction in oil-layer thickness is accompanied by a shorter fiber-to-droplet distance, the fluorescence signal exhibits a substantially larger enhancement of approximately 50%, reflecting the combined contributions of reduced absorption losses and enhanced excitation efficiency. Consistent with this interpretation, the excitation intensity at the particle surface increases markedly in the right column across all angular positions.

Overall, these results demonstrate that minimizing the oil layer thickness improves fluorescence detection through two mechanisms: reduced absorption losses in the oil and enhanced excitation efficiency due to excitation beam narrowing. While oil-layer absorption alone yields a measurable fluorescence enhancement, changes in excitation geometry significantly amplify the effect. Consequently, even small variations in tot_o and fiber-to-droplet distance can lead to substantial changes in fluorescence intensity, highlighting the importance of maintaining consistent droplet size and channel geometry in opt microfluidic platforms.

Design Perspective for Improved Fluorescence Signal

This study identifies three key factors that enhance fluorescence signal detection from droplet-encapsulated microparticles: the particle-to-droplet size ratio (Dp∗D_p^*), the particle’s radial and angular position (rp∗r_p^*, θp\theta_p), and the oil layer thickness (tot_o) separating the droplet from the channel wall.

First, Dp∗D_p^* governs both the fluorescence intensity and its sensitivity to particle size. The fluorescence signal increases strongly from Dp∗=0.33D_p^* = 0.33 to 0.50.5, followed by a more gradual rise between 0.50.5 and 0.660.66. This nonlinear dependence suggests two operational regimes: for size-sensitive detection, the lower-to-intermediate range (Dp∗=0.33D_p^* = 0.33–0.50.5) provides high sensitivity to particle size. In contrast, operation at larger Dp∗D_p^* values (0.50.5–0.660.66) yields higher absolute fluorescence signals with reduced sensitivity to small size variations, enabling more uniform signal levels across similarly sized particles. This ratio can be tuned by adjusting droplet diameter through flow rate control or droplet junction geometry [53, 54]. However, smaller junctions pose fabrication challenges and increase clogging risk. In platforms with shallow channels (130 μm130\ \mu\mathrm{m}), droplet spacing and stability must also be balanced. Second, the particle position within the droplet affects both signal strength and consistency. For Dp∗=0.3D_p^* = 0.3, particles near the center (rp∗<0.4r_p^* < 0.4) yield more stable signals regardless of angle, while peripheral positions (rp∗>0.4r_p^* > 0.4) increase angular sensitivity. Thus, placing particles near the optical axis improves reliability. Aligning detection geometry with fluid flow enhances signal capture. Pre-alignment strategies [55, 56], especially guiding particles toward the channel wall adjacent to the excitation fiber (see the Supplementary Material [28]), improve their post-encapsulation positioning.

Third, the oil layer thickness is a critical determinant of signal strength due to its impact on optical losses. Thinner oil layers improve both excitation delivery and fluorescence collection. Simulations show nearly twofold signal enhancement when tot_o is reduced (Figure 7(c)). Channel constriction near the interrogation zone [17] or multilayer designs [57] can help reduce tot_o, but may introduce complexity or instability. A simpler and scalable strategy is to match droplet diameter to channel height, ensuring consistent and minimal oil spacing—achievable via flow tuning and junction geometry [53, 54].

In summary, fluorescence signal in optomicrofluidic systems can be optimized by: (i) selecting Dp∗=0.5D_p^* = 0.5–0.660.66 for size sensitivity or 0.330.33–0.50.5 for signal uniformity, (ii) ensuring particle pre-alignment toward the excitation side for consistent post-encapsulation positioning, and (iii) minimizing oil layer thickness by matching droplet size to channel height. These experimentally accessible strategies offer a robust framework to enhance fluorescence detection performance and scalability in future droplet-based optofluidic platforms.

Conclusion

This work combined experiments and simulations to investigate light interactions with particle-encapsulated droplets in a fiber-integrated optomicrofluidic platform. We systematically studied the influence of particle-to-droplet size ratio (Dp∗D_p^*), particle position (rp∗,θpr_p^*, \theta_p), and oil layer thickness (tot_o) on refracted and fluorescence signals. In refracted signal analysis, we identified two optical signatures: (i) droplet-refracted signal (DRS) and (ii) particle-refracted signal (PRS). DRS correlated reliably with droplet size, while PRS enabled label-free detection of encapsulated particles for Dp∗=0.23D_p^* = 0.23–0.330.33, revealing scattering-based detection potential. Fluorescence studies show that the signal intensity increases strongly from Dp∗=0.33D_{\mathrm{p}}^{*}=0.33 to 0.5, followed by a more gradual increase up to 0.66. This defines two regimes: Dp∗=0.33D_{\mathrm{p}}^{*}=0.33–0.5 provides high sensitivity to particle size, while Dp∗=0.5D_{\mathrm{p}}^{*}=0.5–0.66 yields higher fluorescence intensity with reduced sensitivity to small size variations. Particle position significantly impacted signal consistency. Central positioning (rp∗<0.4r_{\mathrm{p}}^{*}<0.4) minimized angular dependence, yielding uniform fluorescence, whereas off-center locations (rp∗>0.4r_{\mathrm{p}}^{*}>0.4) introduced angular sensitivity and signal variability. Positioning particles closer to the optical axis is thus key for reliable detection. Reducing the oil layer thickness enhanced fluorescence by lowering optical loss at the droplet–channel interface. Matching droplet size to channel height is an effective and practical strategy for achieving stable, minimal oil layers.

Together, these findings establish a design framework for optimizing fluorescence detection in droplet-based optomicrofluidic systems. The insights presented here are applicable to high-throughput, label-free, and fluorescence-based single-cell analysis platforms, especially those requiring sensitivity to cellular heterogeneity and fine biophysical variations.

Acknowledgments

The authors acknowledge support from IIT Madras via project no. RF21220988MERFIR008509, and by the Ministry of Human Resources and Development, Government of India, through the Institute of Eminence (IoE) project no. SB22231233MEETWO008509 via grant no. 11/9/2019-U.3(A). The authors would like to extend appreciation to CNNP, IIT Madras for facilitating device fabrication.

Photograph of experimental setup

Figure 8. Photograph of experimental setup

Effect of flow rate ratio on droplet size, droplet generation rate, and DRS characteristics

Figure 9. (a) Effect of flow rate ratio on droplet size and droplet generation rate. (b) Variations of peak height of the DRS (SdrS_{\mathrm{dr}}) and peak width at 90% peak height (tdrt_{\mathrm{dr}}) with flow rate ratio.

Light–Droplet Interaction: Numerical Model (Ray Optics)

This section describes the ray-optics based numerical model used to simulate light propagation and its interaction with droplets and encapsulated particles inside the microfluidic channel. The model is designed to reproduce the experimental excitation geometry and optical paths in a transparent and reproducible manner. The simulated domain corresponds to the experimentally used PDMS microfluidic device, restricted to the optical interaction region. The microchannel has a width of 100 μ\mum, a depth of 130 μ\mum, and a simulated length of 800 μ\mum. The excitation single-mode fiber (SMF) has a core diameter of 9 μ\mum and a cladding diameter of 125 μ\mum, while the multimode fiber (MMF) has a core diameter of 62.5 μ\mum and a cladding diameter of 125 μ\mum. The distance between SMF tip and the adjacent channel wall is 65 µm, and the distance between the MMF tip and the fluid channel wall is 140 µm. These dimensions match the experimental configuration.

Light propagation is modeled using a ray-optics framework, where ray trajectories are governed by the refractive index nn and refraction at material interfaces is computed using Snell’s law. Each material region is treated as optically homogeneous with a constant refractive index: water (n=1.33n = 1.33), oil (n=1.47n = 1.47), PDMS (n=1.43n = 1.43), single-mode fiber core (n=1.45n = 1.45), single-mode fiber cladding (n=1.44n = 1.44), multimode fiber cladding (n=1.428n = 1.428), and the microparticle (n=1.59n = 1.59). Rays propagate within each medium using the local refractive index, and the refractive index is updated at material interfaces. Ray positions are updated at fixed propagation intervals to ensure stable ray tracking along the full optical path.

To represent light emerging from the excitation SMF, rays are released from hexapolar grid points distributed across the SMF core cross-section. The ray-release plane is defined 200 µm upstream of the SMF exit facet, allowing the angular distribution of rays to develop before interaction with the surrounding PDMS and fluid domains. A hexapolar grid is used to sample the fiber core, providing uniform spatial coverage while preserving rotational symmetry. From each grid point, rays are launched within a conical distribution defined by the total internal reflection at core-clad interface of the fiber. This approach reproduces the angular divergence and spatial intensity distribution characteristic of fiber-emitted light.

Fluorescence Simulation (PDE module)

The fluorescence model was implemented such that light diffusion was computed separately within each medium, using the corresponding diffusion and absorption coefficients for PDMS, mineral oil, and water. The excitation intensity distribution required for the fluorescence calculation was obtained from ray-optics simulations. A parametric study was performed to assess the influence of optical parameters on the simulated fluorescence signal. The parameters investigated include the absorption and reduced scattering coefficients of PDMS, mineral oil, and water, with the nominal values provided in Table 1. For each parameter, the nominal value was reduced by a factor of 10 and increased by a factor of 10, while all other parameters were kept constant. The results show that variations in the absorption coefficient of PDMS have the strongest influence on the fluorescence intensity, while changes in the absorption coefficient of the oil phase have a smaller effect. Variations in the remaining parameters result in negligible changes to the fluorescence signal within the explored range.

ParameterValue (m−1^{-1})
μa,PDMS\mu_{\mathrm{a,PDMS}}0.5 [42, 43]
μs,PDMS\mu_{\mathrm{s,PDMS}}5 [42]
μa,Oil\mu_{\mathrm{a,Oil}}2.3 [44, 45]
μs,Oil\mu_{\mathrm{s,Oil}}0.031 [46, 47]
μa,Water\mu_{\mathrm{a,Water}}0.2629 [48, 49]
μs,Water\mu_{\mathrm{s,Water}}0.0009 [48]

Table 1. Parameters for fluorescence simulation

Parity plots corresponding to these simulations are presented in the main manuscript. The particle positions used for the parity analysis are summarized in Table 2.

Particle numberDdD_d [µm]θp\theta_p [°]rpr_p [µm]
P159.230818
P251.420718
P35318019
P451.4018
P556.926520
P651.42716
P754.79616

Table 2. Particle position information used for validation of fluorescence simulation

Cumulative distribution functions of the fluorescence signal for the two $r_p^*$ groups

Figure 10. Cumulative distribution functions of the fluorescence signal for the two rp∗r_p^* groups.

Effect of Droplet Size and Particle Position on Fluorescence Signal

The impact of droplet encapsulation factors were investigated using simulations. Simulations are performed for droplets of diameters 30 μm\mu\mathrm{m}, 50 μm\mu\mathrm{m}, and 75 μm\mu\mathrm{m} within a 100 μm\mu\mathrm{m}-wide fluidic channel (WcW_c). In each case, the encapsulated particles are positioned near the droplet boundary, with a fixed rpr_p such that space between particle boundary and droplet boundary is 1.5 μm\mu\mathrm{m} and θp\theta_p varied in 45∘^\circ increments. As shown in Figure 11, decreasing the droplet size leads to an increase in the excitation light intensity at the bead surface, as well as stronger bead scattering. The overall fluorescence signal also increases for smaller droplets. These simulation results also highlight the interplay between droplet size, oil layer thickness, and bead position on the resulting fluorescence signal intensity.

Simulation results for varied droplet size and bead positions

Figure 11. Simulation results for varied droplet size and bead positions. (a) Light intensity reaching bead surface. (b) Bead scattering intensity reaching the 135° MMF. (c) Fluorescence intensity from beads reaching the 135° MMF.

Positional correlation between particle pre and post encapsulation

Figure 12. Positional correlation between particle pre and post encapsulation. (i)-(iv) represent 4 positions of a flow focusing optofluidic device. (i) Pre-encapsulation region (ii) Encapsulation region (iii) Post-encapsulation region (iv) Light interaction region. Encapsulation dependence is shown for three regions of the droplet: (a) Region close to excitation source (b) Center region (c) Region away from the excitation source.

References

  1. [1]Kuangwen Hsieh et al. “Combating Antimicrobial Resistance via Single-Cell Diagnostic Technologies Powered by Droplet Microfluidics”. In: Acc. Chem. Res. 55.2 (Dec. 2021), pp. 123–133. ISSN: 1520-4898. DOI: 10.1021/acs.accounts.1c00462. URL: http://dx.doi.org/10.1021/acs.accounts.1c00462.
  2. [2]Ziyi Yu et al. “Droplet-based microfluidic screening and sorting of microalgal populations for strain engineering applications”. In: Algal Res. 56 (June 2021), p. 102293. ISSN: 2211-9264. DOI: 10.1016/j.algal.2021.102293. URL: http://dx.doi.org/10.1016/j.algal.2021.102293.
  3. [3]Yuetong Wang et al. “Advances of droplet-based microfluidics in drug discovery”. In: Expert Opin. Drug Discov. 15.8 (Apr. 2020), pp. 969–979. ISSN: 1746-0445. DOI: 10.1080/17460441.2020.1758663. URL: http://dx.doi.org/10.1080/17460441.2020.1758663.
  4. [4]Mira T. Guo et al. “Droplet microfluidics for high-throughput biological assays”. In: Lab Chip 12.12 (2012), p. 2146. ISSN: 1473-0189. DOI: 10.1039/C2LC21147E. URL: http://dx.doi.org/10.1039/C2LC21147E.
  5. [5]Ralf Seemann et al. “Droplet based microfluidics”. In: Rep. Prog. Phys. 75.1 (Dec. 2011), p. 016601. ISSN: 1361-6633. DOI: 10.1088/0034-4885/75/1/016601. URL: http://dx.doi.org/10.1088/0034-4885/75/1/016601.
  6. [6]Preksha Gupta et al. “Multiplexed fluorescence and scatter detection with single cell resolution using on-chip fiber optics for droplet microfluidic applications”. In: Microsyst. Nanoeng. 10.1 (Mar. 2024), pp. 1–12. ISSN: 2055-7434. URL: http://dx.doi.org/10.1038/s41378-024-00665-w.
  7. [7]David Hess, Tianjin Yang, and Stavros Stavrakis. “Droplet-based optofluidic systems for measuring enzyme kinetics”. In: Anal. Bioanal. Chem. 412.14 (Dec. 2019), pp. 3265–3283. ISSN: 1618-2650. DOI: 10.1007/s00216-019-02294-z. URL: http://dx.doi.org/10.1007/s00216-019-02294-z.
  8. [8]Ouriel Caen et al. “High-throughput multiplexed fluorescence-activated droplet sorting”. In: Microsyst. Nanoeng. 4.1 (Oct. 2018), p. 33. ISSN: 2055-7434. URL: http://dx.doi.org/10.1038/s41378-018-0033-2.
  9. [9]Kaiser Pärnamets et al. “Optical Detection Methods for High-Throughput Fluorescent Droplet Microflow Cytometry”. In: Micromachines 12.3 (Mar. 2021), p. 345. ISSN: 2072-666X. DOI: 10.3390/mi12030345. URL: http://dx.doi.org/10.3390/mi12030345.
  10. [10]Jatin Panwar, Alexis Autour, and Christoph A. Merten. “Design and construction of a microfluidics workstation for high-throughput multi-wavelength fluorescence and transmittance activated droplet analysis and sorting”. In: Nat. Protoc. 18.4 (Jan. 2023), pp. 1090–1136. ISSN: 1750-2799. DOI: 10.1038/s41596-022-00796-2. URL: http://dx.doi.org/10.1038/s41596-022-00796-2.
  11. [11]Can Huang et al. “Droplet Detection and Sorting System in Microfluidics: A Review”. In: Micromachines 14.1 (Dec. 2022), p. 103. ISSN: 2072-666X. DOI: 10.3390/mi14010103. URL: http://dx.doi.org/10.3390/mi14010103.
  12. [12]Frank B. Myers and Luke P. Lee. “Innovations in optical microfluidic technologies for point-of-care diagnostics”. In: Lab Chip 8.12 (2008), p. 2015. ISSN: 1473-0189. DOI: 10.1039/B812343H. URL: http://dx.doi.org/10.1039/B812343H.
  13. [13]Sundar Hengouju et al. “Advantages of optical fibers for facile and enhanced detection in droplet microfluidics”. In: Biosens. Bioelectron. 200 (Mar. 2022), p. 113910. ISSN: 0956-5663. DOI: 10.1016/j.bios.2021.113910. URL: http://dx.doi.org/10.1016/j.bios.2021.113910.
  14. [14]Walter Schäfer and Cameron Tropea. “Time-shift technique for simultaneous measurement of size, velocity, and relative refractive index of transparent droplets or particles in a flow”. In: Appl. Opt. 53.4 (Jan. 2014), p. 588. ISSN: 2155-3165. DOI: 10.1364/AO.53.000588. URL: http://dx.doi.org/10.1364/AO.53.000588.
  15. [15]Jeonggi Seo and Luke P. Lee. “Disposable integrated microfluidics with self-aligned planar microlenses”. In: Sens. Actuators B Chem. 99.2–3 (May 2004), pp. 615–622. ISSN: 0925-4005. DOI: 10.1016/j.snb.2003.11.014. URL: http://dx.doi.org/10.1016/j.snb.2003.11.014.
  16. [16]A. Llobera et al. “Multiple internal reflection poly(dimethylsiloxane) systems for optical sensing”. In: Lab Chip 7.11 (2007), p. 1560. ISSN: 1473-0189. DOI: 10.1039/b704454b. URL: http://dx.doi.org/10.1039/B704454B.
  17. [17]Fabrice Gielen et al. “Ultrahigh-throughput–directed enzyme evolution by absorbance-activated droplet sorting (AADS)”. In: Proc. Natl. Acad. Sci. 113.47 (Nov. 2016), E7383–E7389. ISSN: 1091-6490. DOI: 10.1073/pnas.1606927113. URL: http://dx.doi.org/10.1073/pnas.1606927113.
  18. [18]A. Mohan et al. “A microfluidic flow analyzer with integrated lensed optical fibers”. In: Biomicrofluidics 14.5 (Sept. 2020), p. 054104. ISSN: 1932-1058. DOI: 10.1063/5.0013250. URL: http://dx.doi.org/10.1063/5.0013250.
  19. [19]Minhui Liang et al. “Lab-In-Fiber Optofluidic Device for Droplet Digital Polymerase Chain Reaction (DdPCR) with Real-Time Monitoring”. In: ACS Sens. 9.10 (Sept. 2024), pp. 5275–5283. DOI: 10.1021/acssensors.4c01467. URL: https://doi.org/10.1021/acssensors.4c01467.
  20. [20]Li Liang et al. “Label-free single-cell analysis in microdroplets using a light-scattering-based optofluidic chip”. In: Biosens. Bioelectron. 253 (June 2024), p. 116148. ISSN: 0956-5663. DOI: 10.1016/j.bios.2024.116148. URL: http://dx.doi.org/10.1016/j.bios.2024.116148.
  21. [21]Qingling Li et al. “Consecutive Sorting and Phenotypic Counting of CTCs by an Optofluidic Flow Cytometer”. In: Anal. Chem. 91.21 (Sept. 2019), pp. 14133–14140. ISSN: 1520-6882. DOI: 10.1021/acs.analchem.9b04035. URL: http://doi.org/10.1021/acs.analchem.9b04035.
  22. [22]Chiyuan Gao et al. “Development of a Microfluidic Flow Cytometer with a Uniform Optical Field (Uni-μFCM) Enabling Quantitative Analysis of Single-Cell Proteins and Its Applications in Leukemia Gating, Tumor Classification, and Hierarchy of Cancer Stem Cells”. In: ACS Sens. 8.9 (Aug. 2023), pp. 3498–3509. ISSN: 2379-3694. DOI: 10.1021/acssensors.3c01060. URL: http://dx.doi.org/10.1021/acssensors.3c01060.
  23. [23]Nien-Tsu Huang et al. “Recent advancements in optofluidics-based single-cell analysis: optical on-chip cellular manipulation, treatment, and property detection”. In: Lab Chip 14.7 (2014), pp. 1230–1245. ISSN: 1473-0189. DOI: 10.1039/c3lc51211h. URL: http://dx.doi.org/10.1039/C3LC51211H.
  24. [24]Hamed Tavakoli et al. “Recent advances in microfluidic platforms for single-cell analysis in cancer biology, diagnosis and therapy”. In: TrAC Trends Anal. Chem. 117 (Aug. 2019), pp. 13–26. ISSN: 0165-9936. DOI: 10.1016/j.trac.2019.05.010. URL: http://dx.doi.org/10.1016/j.trac.2019.05.010.
  25. [25]Shrishti Kumari et al. “Microfluidic Platforms for Single Cell Analysis: Applications in Cellular Manipulation and Optical Biosensing”. In: Chemosensors 11.2 (Feb. 2023), p. 107. ISSN: 2227-9040. DOI: 10.3390/chemosensors11020107. URL: http://dx.doi.org/10.3390/chemosensors11020107.
  26. [26]Matthias Koegl, Christoph Weiß, and Lars Zigan. “Fluorescence Spectroscopy for Studying Evaporating Droplets Using the Dye Eosin-Y”. In: Sensors 20.21 (Oct. 2020), p. 5985. ISSN: 1424-8220. DOI: 10.3390/s20215985. URL: http://dx.doi.org/10.3390/s20215985.
  27. [27]P. Sajeesh, M. Doble, and A. K. Sen. “Hydrodynamic resistance and mobility of deformable objects in microfluidic channels”. In: Biomicrofluidics 8.5 (Sept. 2014), p. 054112. ISSN: 1932-1058. DOI: 10.1063/1.4897332. URL: http://dx.doi.org/10.1063/1.4897332.
  28. [28]See the Supplemental Material for additional figures, experimental characterization, and simulation details, including ray-optics/fluorescence modeling, parameter sensitivity analysis, and droplet-size effects on fluorescence.
  29. [29]Jiaomeng Zhu et al. “Optofluidics: the interaction between light and flowing liquids in integrated devices”. In: Opto-Electron. Adv. 2.11 (2019), pp. 19000701–19000710. ISSN: 2096-4579. DOI: 10.29026/oea.2019.190007. URL: http://dx.doi.org/10.29026/oea.2019.190007.
  30. [30]H. G. Houghton and W. R. Chalker. “The Scattering Cross Section of Water Drops in Air for Visible Light”. In: J. Opt. Soc. Am. 39.11 (Nov. 1949), p. 955. ISSN: 0030-3941. DOI: 10.1364/josa.39.000955. URL: http://dx.doi.org/10.1364/josa.39.000955.
  31. [31]Lingxi Li et al. “Simulation of light scattering from a colloidal droplet using a polarized Monte Carlo method: application to the time-shift technique”. In: Opt. Express 27.25 (Nov. 2019), p. 36388. ISSN: 1094-4087. DOI: 10.1364/OE.27.036388. URL: http://dx.doi.org/10.1364/OE.27.036388.
  32. [32]Max Born et al. Principles of Optics: Electromagnetic Theory of Propagation, Interference and Diffraction of Light. Cambridge University Press, Oct. 1999. ISBN: 9781139644181. DOI: 10.1017/cbo9781139644181.
  33. [33]V. Vinothkumar and Raj C. Thiagarajan. Macro Optical Cloaking in Product Design by Ray Optics. Tech. rep. HAL archive ID: tel-02916097. COMSOL Conf. Proc., 2016.
  34. [34]Ray Optics Module User’s Guide. Version 6.0. Accessed via COMSOL Multiphysics® software documentation. COMSOL AB. Stockholm, Sweden, 2020.
  35. [35]Beth Schaefer et al. “Measuring the Stokes polarization parameters”. In: Am. J. Phys. 75.2 (Feb. 2007), pp. 163–168. ISSN: 1943-2909. DOI: 10.1119/1.2386162. URL: http://dx.doi.org/10.1119/1.2386162.
  36. [36]Elke Haustein and Petra Schwille. “Trends in fluorescence imaging and related techniques to unravel biological information”. In: HFSP J. 1.3 (Sept. 2007), pp. 169–180. ISSN: 1955-2068. DOI: 10.2976/1.2778852. URL: http://dx.doi.org/10.2976/1.2778852.
  37. [37]Chon U. Chan and Claus-Dieter Ohl. “Surface Nanobubble Nucleation Visualized with TIRF Microscopy”. In: arXiv preprint arXiv:1204.2633 abs/1204.2633 (2012). Accessed: 2025-05-12. URL: https://arxiv.org/abs/1204.2633.
  38. [38]M. I. Cotterell et al. “Accurate Measurement of the Optical Properties of Single Aerosol Particles Using Cavity Ring-Down Spectroscopy”. In: J. Phys. Chem. A 126.17 (Apr. 2022), pp. 2619–2631. ISSN: 1520-5215. DOI: 10.1021/acs.jpca.2c01246. URL: http://dx.doi.org/10.1021/acs.jpca.2c01246.
  39. [39]G. Persichetti et al. “Multifunctional optofluidic lab-on-chip platform for Raman and fluorescence spectroscopic microfluidic analysis”. In: Lab Chip 17.15 (2017), pp. 2631–2639. ISSN: 1473-0139. DOI: 10.1039/C7LC00460E. URL: http://dx.doi.org/10.1039/C7LC00460E.
  40. [40]Soorya Peter. “Comparative Study on 3D Modelling of Breast Cancer Using Nir-Fdot in Comsol”. In: Proceedings of the COMSOL Conference. 2014. URL: https://www.comsol.co.in/paper/download/210461/oorypater_paper.pdf.
  41. [41]Rachee Singh and Iven Jose. “Diffuse Optical Tomography: A Simulation Based Approach”. In: COMSOL Conf. Proc. 2011, pp. 1–3.
  42. [42]Gage J. Greening et al. “Characterization of thin poly(dimethylsiloxane)-based tissue-simulating phantoms with tunable reduced scattering and absorption coefficients at visible and near-infrared wavelengths”. In: Journal of Biomedical Optics 19.11 (Nov. 2014), p. 115002. ISSN: 1083-3668. DOI: 10.1117/1.jbo.19.11.115002. URL: http://dx.doi.org/10.1117/1.JBO.19.11.115002.
  43. [43]Michael Ian Lapsley et al. “A single-layer, planar, optofluidic Mach–Zehnder interferometer for label-free detection”. In: Lab on a Chip 11.10 (2011), p. 1795. ISSN: 1473-0189. DOI: 10.1039/C0LC00707B. URL: http://dx.doi.org/10.1039/C0LC00707B.
  44. [44]A. Marín-Serrano et al. “Thermo-optical properties as complementary parameters for damage assessment of mineral oils aged under controlled conditions used in power transformers”. In: Thermochimica Acta 676 (June 2019), pp. 33–38. ISSN: 0040-6031. DOI: 10.1016/j.tca.2019.03.025. URL: http://dx.doi.org/10.1016/j.tca.2019.03.025.
  45. [45]Piotr Przbyylek. “Determination of Mineral Oil Concentration in the Mixture with Synthetic Ester Using Near-Infrared Spectroscopy”. In: Energies 16.17 (Sept. 2023), p. 6381. ISSN: 1996-1073. DOI: 10.3390/en16176381. URL: http://dx.doi.org/10.3390/en16176381.
  46. [46]A.A. Aguilar-Arevalo, C.E. Anderson, L.M. Bartoszek, et al. “The MiniBooNE detector”. In: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 599.1 (Feb. 2009), pp. 28–46. ISSN: 0168-9002. DOI: 10.1016/j.nima.2008.10.028. URL: http://dx.doi.org/10.1016/j.nima.2008.10.028.
  47. [47]S.S. Gokhale et al. “A spectrometric approach to measuring the Rayleigh scattering length for liquid scintillator detectors”. In: Journal of Instrumentation 16.03 (Mar. 2021), P03009. ISSN: 1748-0221. DOI: 10.1088/1748-0221/16/03/P03009. URL: http://dx.doi.org/10.1088/1748-0221/16/03/P03009.
  48. [48]Hendrik Buiteveld, J. H. M. Hakvoort, and M. Donze. “Optical properties of pure water”. In: Ocean Optics XII. Ed. by Jules S. Jaffe. SPIE, Oct. 1994. DOI: 10.1117/12.190060. URL: http://dx.doi.org/10.1117/12.190060.
  49. [49]Robin M. Pope and Edward S. Fry. “Absorption spectrum (380–700 nm) of pure water II Integrating cavity measurements”. In: Applied Optics 36.33 (Nov. 1997), p. 8710. ISSN: 1539-4522. DOI: 10.1364/ao.36.008710. URL: http://dx.doi.org/10.1364/AO.36.008710.
  50. [50]Yingchun Wu et al. “Phase rainbow refractometry for accurate droplet variation characterization”. In: Opt. Lett. 41.20 (Oct. 2016), p. 4672. ISSN: 1539-4794. DOI: 10.1364/ol.41.004672. URL: http://dx.doi.org/10.1364/OL.41.004672.
  51. [51]Yong Lu et al. “Systematic Analysis of Cell-to-Cell Expression Variation of T Lymphocytes in a Human Cohort Identifies Aging and Genetic Associations”. In: Immunity 45.5 (Nov. 2016), pp. 1162–1175. ISSN: 1074-7613. DOI: 10.1016/j.immuni.2016.10.025. URL: http://dx.doi.org/10.1016/j.immuni.2016.10.025.
  52. [52]Alenka Djarmila Behsen et al. “Cell surface marker heterogeneity in human myeloma cell lines for modeling of disease and therapy”. In: Sci. Rep. 14.1 (Nov. 2024), p. 28805. ISSN: 2045-2322. DOI: 10.1038/s41598-024-80263-y. URL: http://dx.doi.org/10.1038/s41598-024-80263-y.
  53. [53]Ali Lashkaripour et al. “Performance tuning of microfluidic flow-focusing droplet generators”. In: Lab Chip 19.6 (2019), pp. 1041–1053. ISSN: 1473-0189. DOI: 10.1039/C8LC01253A. URL: http://dx.doi.org/10.1039/C8LC01253A.
  54. [54]Matthew Stevens, Eugeniu Balaur, and Brian Abbey. “Computational simulation of the effects of interfacial tension in microfluidic flow focusing droplet generators”. In: Front. Phys. 11 (Feb. 2023), p. 1060780. ISSN: 2296-424X. DOI: 10.3389/fphy.2023.1060780. URL: http://dx.doi.org/10.3389/fphy.2023.1060780.
  55. [55]R. Gaikwad and A. K. Sen. “An optomicrofluidic device for the detection and isolation of drop-encapsulated target cells in single-cell format”. In: Analyst 146.1 (2021), pp. 95–108. ISSN: 1364-5528. DOI: 10.1039/d0an00160k. URL: http://dx.doi.org/10.1039/D0AN00160K.
  56. [56]Xiaoyu Yue et al. “Breaking through the Poisson Distribution: A compact high-efficiency droplet microfluidic system for single-bead encapsulation and digital immunoassay detection”. In: Biosens. Bioelectron. 211 (Sept. 2022), p. 114384. ISSN: 0956-5663. DOI: 10.1016/j.bios.2022.114384. URL: http://dx.doi.org/10.1016/j.bios.2022.114384.
  57. [57]Miguel Tovar et al. “3D-glass molds for facile production of complex droplet microfluidic chips”. In: Biomicrofluidics 12.2 (Mar. 2018), p. 024115. ISSN: 1932-1058. DOI: 10.1063/1.5013325. URL: http://dx.doi.org/10.1063/1.5013325.

Paper details

vlnc:W_kqqs4rqr
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 0

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents