betaFeedback

WorksPhysics and Astronomy

The CeBrA demonstrator for particle-γγ coincidence experiments at the FSU Super-Enge Split-Pole Spectrograph

Abstract

We report on a highly selective experimental setup for particle-γγ coincidence experiments at the Super-Enge Split-Pole Spectrograph (SE-SPS) of the John D. Fox Superconducting Linear Accelerator Laboratory at Florida State University (FSU) using fast CeBr3_3 scintillators for γγ-ray detection. Specifically, we report on the results of characterization tests for the first five CeBr3_3 scintillation detectors of the CeBr3_3 Array (CeBrA) with respect to energy resolution and timing characteristics. We also present results from the first particle-γγ coincidence experiments successfully performed with the CeBrA demonstrator and the FSU SE-SPS. We show that with the new setup, γγ-decay branching ratios and particle-γγ angular correlations can be measured very selectively using narrow excitation energy gates, which are possible thanks to the excellent particle energy resolution of the SE-SPS. In addition, we highlight that nuclear level lifetimes in the nanoseconds regime can be determined by measuring the time difference between particle detection with the SE-SPS focal-plane scintillator and γγ-ray detection with the fast CeBrA detectors. Selective excitation energy gates with the SE-SPS exclude any feeding contributions to these lifetimes.

Introduction

Particle or γ\gamma-ray spectroscopy experiments alone can oftentimes not provide unambiguous nuclear structure information. For particle spectroscopy, examples could be unresolved excited states due to limited particle energy resolution of the detector or inconclusive angular distributions measured after a nuclear reaction with, e.g., a magnetic spectrograph or silicon detector array. For γ\gamma-ray spectroscopy, depending on the design of the experiment and the γ\gamma-ray detectors used, the encountered problems can be quite similar. Particle-γ\gamma coincidences, when combined with selective nuclear reactions, provide the means to mitigate these problems and also offer a unique window into nuclear-structure phenomena, many of which are important to understanding nuclear reactions taking place in stellar environments.

Experimental setups which combine high-resolution magnetic spectrographs with γ\gamma-ray detection capabilities are extremely powerful as additional selectivity to different excitation and decay channels can be gained. There are a few examples of existing quasi-permanent setups. They include, e.g., the combined GRETINA-S800 [1], SeGA-S800 [2], and CAESAR-S800 [3] setups at the National Superconducting Cyclotron Laboratory (NSCL) at Michigan State University [4] [now the Facility for Rare Isotope Beams (FRIB)] as well as the γ\gamma-ray spectrometer DALI2 coupled to the different spectrometers at the RIKEN Radioactive Isotope Beam Factory [5]. These setups are, however, used for experiments with fast rare-isotope beams, where position resolution is critical for Doppler reconstruction. Particle-γ\gamma coincidence setups with magnetic spectrographs, which temporarily existed at stable beam facilities, include, e.g., an HPGe array at the Big-Bite Spectrometer of the KVI Groningen [6] and the CAGRA array at the Grand Raiden spectrometer of the RCNP Osaka [7]. First experiments have also been conducted with the BaGeL array at the K600 magnetic spectrometer of iThemba Labs [8].

In this article, we report on a new experimental setup for particle-γ\gamma coincidence experiments at the Super-Enge Split-Pole Spectrograph (SE-SPS) of the John D. Fox Superconducting Linear Accelerator Laboratory at Florida State University (FSU) using fast, low-background CeBr3\mathrm{CeBr}_3 scintillators for γ\gamma-ray detection. The γ\gamma-ray detection setup at the SE-SPS will be referred to as CeBrA (for CeBr3\mathrm{CeBr}_3 Array) in the following. Thanks to the excellent particle energy resolution of the SE-SPS, narrow excitation energy gates can be set, which allow the selective study of the γ\gamma decay of excited states populated through light-ion induced nuclear reactions with CeBrA. The good energy resolution of the CeBr3\mathrm{CeBr}_3 detectors enables the identification of γ\gamma decays leading to different final states. The narrow excitation energy gates also exclude any feeding contributions when studying particle-γ\gamma angular correlations for assigning spin-parity quantum numbers and when determining lifetimes with, e.g., fast-timing techniques. In contrast to other γ\gamma-ray detectors with comparable or better energy resolution, the CeBr3\mathrm{CeBr}_3 detectors can be operated in the intense γ\gamma-ray and neutron background that comes with (d,pγ)(d,p\gamma) experiments at rates as high as 250 kilocounts/s (kcps) without running into pile-up problems or losing spectral quality during and after the experiment due to radiation damage.

Detailed studies of the influence of CeBr3\mathrm{CeBr}_3 crystal properties on the scintillation process, light yield, energy resolution, timing characteristics, and their implications for spectroscopy applications were first presented in Refs. [9, 10, 11]. Unlike LaBr3\mathrm{LaBr}_3, CeBr3\mathrm{CeBr}_3 crystals do not suffer from the intrinsic γ\gamma-ray and α\alpha-particle background between 0.5 MeV and 3 MeV, which is caused by the presence of radioactive 138La{}^{138}\mathrm{La} and 227Ac{}^{227}\mathrm{Ac} contaminants in LaBr3\mathrm{LaBr}_3 crystals [9]. Because of the lower background, the superiority of CeBr3\mathrm{CeBr}_3 over LaBr3\mathrm{LaBr}_3 for detecting low-energy γ\gamma rays emitted in the decay of, e.g., actinide nuclei was highlighted in Ref. [12]. In addition, the near temperature independent response of the scintillation yield for CeBr3\mathrm{CeBr}_3 crystals [13] as well as their very competitive radiation hardness were demonstrated [9, 13]. Given that the ∼4 %\sim4\,\% relative energy resolution at 662 keV is only about 25 % worse than for LaBr3\mathrm{LaBr}_3 [9], CeBr3\mathrm{CeBr}_3 detectors offer an attractive and price-effective alternative between low-resolution NaI and comparably expensive, high-resolution HPGe detectors, which also need to be cooled cryogenically and, thus, typically occupy more space around the experimental setup. HPGe detectors are also subject to severe radiation damage in environments with intense neutron background. Furthermore, since the material is composed of heavier elements (the effective ZZ is 45.9), CeBr3\mathrm{CeBr}_3 features a higher γ\gamma-ray detection efficiency than HPGe detectors for comparable crystal sizes. This enhanced detection efficiency is beneficial if higher-energy γ\gamma rays are to be detected and if a small-scale array is considered. As for LaBr3\mathrm{LaBr}_3, it has already been shown that co-doping of the crystal with Strontium can further improve the energy resolution [11]. Large, co-doped CeBr3\mathrm{CeBr}_3 crystals are, to our knowledge, not commercially available yet. The timing properties of small, 1″ × 1″ CeBr3\mathrm{CeBr}_3 detectors have already been studied in a two-detector setup and by replacing one CeBr3\mathrm{CeBr}_3 detector with a fast reference BaF2\mathrm{BaF}_2 detector using 22Na{}^{22}\mathrm{Na} and 60Co{}^{60}\mathrm{Co} standard calibration sources [10, 14]. The authors of Ref. [10] reported a timing resolution of around 119 ps when using a fast reference BaF2\mathrm{BaF}_2 detector, which they found to be comparable to LaBr3\mathrm{LaBr}_3 detectors making CeBr3\mathrm{CeBr}_3 scintillators well suited for fast-timing measurements. Some additional studies of CeBr3\mathrm{CeBr}_3 detectors for γ\gamma-ray spectroscopy and lifetime measurements were presented in, e.g., Refs. [14, 15, 16, 17, 18, 19].

This article is structured as follows: § 2 will present results for the energy resolution and timing properties of the first five CeBr3\mathrm{CeBr}_3 γ\gamma-ray detectors available at FSU. The data were obtained by using standard calibration sources. In Section 3, we will discuss results from the first particle-γ\gamma coincidence experiments with the CeBrA demonstrator and the SE-SPS. More specifically, it will be shown how particle-γ\gamma coincidences between the SE-SPS and CeBrA can be used to selectively study the γ\gamma decays of excited states to different final states and to determine γ\gamma-decay branching ratios. Here, we will feature the data from 49Ti(d,pγ)50Ti{}^{49}\mathrm{Ti}(d,p\gamma){}^{50}\mathrm{Ti} and 61Ni(d,pγ)62Ni{}^{61}\mathrm{Ni}(d,p\gamma){}^{62}\mathrm{Ni} test experiments. The data from 52Cr(d,pγ)53Cr{}^{52}\mathrm{Cr}(d,p\gamma){}^{53}\mathrm{Cr} and 34S(d,pγ)35S{}^{34}\mathrm{S}(d,p\gamma){}^{35}\mathrm{S}, will be used to highlight the combined setup’s ability to measure particle-γ\gamma angular correlations for spin-parity assignments and to determine nuclear level lifetimes via fast-timing techniques without any feeding contributions.

Characterization of CeBr3 detectors with standard calibration sources

For particle-γ\gamma coincidence experiments at the FSU SE-SPS, four 2″ × 2″ and one 3″ × 4″ low-background, cylindrical CeBr3_3 detectors with Hamamatsu R6231 and R6233 PMTs (all with positive bias), respectively, were acquired from Berkeley Nucleonics (BNC) [13] and Advatech UK [20]. Afterwards, they were thoroughly tested. All detectors have a magnetic shield and built-in voltage divider. High voltage is supplied to the detectors using the iseg MPOD HV system with the EHS F020p unit. Detector signals are recorded using a digital data acquisition (DAQ) based on the CAEN V1725S digitizer with the proprietary DPP-PSD firmware [21]. The digitizer is readout via an optical fiber link connection and data recorded to disk.

Energy resolution

The DPP-PSD filter settings described in Ref. [22] were varied to optimize energy resolution. For the 2″ × 2″ CeBr3_3 detectors, the digital QDC filter settings were a gate of 176 ns, a short gate of 28 ns, and a pre-gate of 148 ns. Similarly, for the 3″ × 4″ CeBr3_3 detector, the filter settings were a gate of 200 ns, a short gate of 28 ns, and a pre-gate of 148 ns. An example of the detector signal and the digital QDC filter windows used for the 2″ × 2″ CeBr3_3 detectors is shown in Figure 1. Recorded γ\gamma-ray spectra for the 3″ × 4″ CeBr3_3 detector are presented in Figure 2. For both crystal sizes, the energy resolution was found to be equal to the vendors’

Digital QDC filter windows for the 2″ × 2″ CeBr$_3$ detectors

Figure 1. The digital QDC filter windows used for the 2″ × 2″ CeBr3_3 detectors with the CAEN V1725S digitizer using the proprietary DPP-PSD firmware. The blue line represents the baseline of the signal, while the green and red lines correspond to the short and long gates, respectively. The black line is the detector signal.

Figure 2. Spectrum of γ\gamma rays emitted after the decay of 60Co^{60}\mathrm{Co} to 60Ni^{60}\mathrm{Ni} (top) and 56Co^{56}\mathrm{Co} to 56Fe^{56}\mathrm{Fe} (bottom) measured with a 3″ × 4″ CeBr3_3 detector. The bottom figure includes vertical lines to illustrate the γ\gamma rays associated with the decay of 56Co^{56}\mathrm{Co}.

specification. As expected (see also Ref. [9]), the full width at half maximum (FWHM) evolves with 1/Eγ1/\sqrt{E_\gamma} (see Figure 3). The energy resolution of the 3″ × 4″ crystal is slightly worse than the one of the 2″ × 2″ crystal (FWHM = 2.8 % (38 keV) compared to 2.6 % (35 keV) at Eγ=1.3E_\gamma= 1.3 MeV). Our results are in agreement with the previously reported energy resolution of 2″ × 2″ CeBr3_3 detectors [9].

Figure 3. The relative full width at half maximum (FWHM) as a function of γ\gamma-ray energy for a 2″ × 2″ CeBr3_3 detector with Hamamatsu R6231 PMT and a 3″ × 4″ CeBr3_3 detector with Hamamatsu R6233 PMT, both with positive bias as recorded with a CAEN V1725S digitizer at FSU. Different standard calibration sources were used.

Timing properties

As mentioned in the introduction, the timing properties of 1″ × 1″ CeBr3_3 detectors have already been studied in a two-detector setup and by replacing one CeBr3_3 detector with a fast reference BaF2_2 detector using 22Na^{22}\mathrm{Na} and 60Co^{60}\mathrm{Co} standard calibration sources [10, 14]. The authors of Ref. [10] reported a timing resolution of around 119 ps measured against a fast reference BaF2_2 detector, which they found to be comparable to LaBr3_3(Ce) detectors. No information on the timing resolution was previously available for the 2″ × 2″ and 3″ × 4″ crystal sizes. For our studies, we used the built-in digital constant fraction discriminator (CFD) offered by CAEN for the V1725S digitizer with the DPP-PSD firmware [22] and followed the optimization procedure outlined in, e.g., Refs. [14, 23]. Furthermore, we used a homogeneous setup, i.e., detectors of the same crystal type. To exclude possible DAQ limitations, two 1.5″ × 1.5″ LaBr3_3(Ce) detectors were lent from Michigan State University. In agreement with published results [24], the timing resolution for the two prompt γ\gamma-ray transitions observed after the β−\beta^- decay of 60^{60}Co was determined to be ∼300\sim300 ps for a setup consisting of two LaBr3_3(Ce) detectors. For a setup consisting of two 2″ × 2″ CeBr3_3 detectors, we measured a timing resolution between 500 ps and 590 ps using the same two prompt γ\gamma-ray transitions. The optimal CFD settings were found to be 44 ns for the CFD delay and 75% for the CFD fraction, which given the slightly longer rise time of our detectors is in line with the results of Ref. [23]. The Advatech UK detectors showed slightly better timing properties than the ones we acquired from Berkeley Nucleonics even though the same components are used. For the 3″ × 4″ detector, we can only state a prompt timing resolution measured relative to a 2″ × 2″ CeBr3_3 detector. Here, we found a timing resolution of ∼750\sim750 ps between the two prompt lines emitted in the β−\beta^- decay of 60^{60}Co. The CFD settings used for the 3″ × 4″ detector were 68 ns for the CFD delay and 75% for the CFD fraction. The worse timing resolution of the CeBr3_3 detectors compared to previous measurements with LaBr3_3 and smaller-size CeBr3_3 detectors [14] can be partly explained due to material differences between LaBr3_3 and CeBr3_3 [10] as well as the larger crystal geometry of our detectors. The Hamamatsu R6231 PMT is also more optimized for energy than for timing resolution (see, e.g., Ref. [25]).

After benchmarking the timing resolution, we tested that we could reliably extract lifetimes with the 2″ × 2″ CeBr3_3 detectors. Two examples using the slope and convolution method for previously known lifetimes of excited states in 133^{133}Cs populated after the decay of 133^{133}Ba [26] are shown in Figure 4. The lifetime for the 81-keV state determined via the slope and convolution methods is in excellent agreement with the literature value [26]. A slight discrepancy is observed for the shorter lifetime with respect to the adopted value (see Figure 4). It should be noted, however, that our result for the lifetime of the 161-keV state nicely agrees with other published data, see, e.g., [26, 27]. For comparison, a Gaussian distribution (orange dashed line) has been fitted to the timing distribution observed for the 276 keV − 161 keV γ\gamma-ray cascade. The asymmetry in the tail indicative of a lifetime in the hundreds of picosecond range can be clearly seen. Note that the FWHM of the prompt contribution changes with γ\gamma-ray energy (see also, e.g., Ref. [14, 28]).

Figure 4. Lifetime determination of the 81-keV (top) and 161-keV (bottom) states in 133^{133}Cs with the 2″ × 2″ CeBr3_3 detectors via the 356-keV and 276-keV γ\gamma-decay branches, respectively, which feed the states directly. See text for further details

Commissioning particle-γ\gamma coincidence experiments with the CeBrA demonstrator at the FSU SE-SPS

The Super-Enge Split-Pole Spectrograph (SE-SPS)

The Super-Enge Split-Pole Spectrograph (SE-SPS) was moved to FSU after the Wright Nuclear Structure Laboratory (WNSL) at Yale University ceased operation. Like any spectrograph of the split-pole design [29, 30], the SE-SPS consists of two pole sections used to momentum-analyze light-ion reaction products and focus them at the magnetic focal plane to identify nuclear reactions and excited states. The split-pole design allows to accomplish approximate transverse focusing as well as to maintain second-order corrections in the polar angle θ\theta and azimuthal angle ϕ\phi, i.e., (x/θ2)≈0(x/\theta^{2}) \approx0 and (x/ϕ2)≈0(x/\phi^{2}) \approx0, over the entire horizontal range [29, 30]. H. Enge specifically designed the SE-SPS spectrograph as a large-acceptance modification to the traditional split-pole design for the WNSL. The increase in solid angle from 2.8 to 12.8 msr was achieved by doubling the pole-gap, making the SE-SPS well-suited for coincidence experiments. At FSU, the SE-SPS was commissioned in 2018. The Silicon Array for Branching Ratio Experiments (SABRE) was commissioned as the first ancillary detector at the SE-SPS for studying unbound resonances relevant for Nuclear Astrophysics [31].

In singles experiments, i.e., stand-alone mode, the SE-SPS with its present light-ion focal plane detection system (see, e.g., Ref. [32] for some details) can be used to study the population of excited states in light-ion induced reactions, determine (differential) cross sections and measure the corresponding angular distributions. The focal-plane detector consists of a position-sensitive ionization chamber with two anode wires to measure energy loss in the isobutane gas and a large plastic scintillator to determine the rest energy of the residual particles passing through the detector. A sample particle identification plot with the energy loss measured by the rear anode wire and the rest energy measured by the scintillator is shown in Figure 5. Unambiguous particle identification is achieved. Under favorable conditions, the detector can be operated at rates as high as two kilocounts/s (kcps). Examples of angular distributions measured with the SE-SPS in 50^{50}Ti(d,pd,p)51^{51}Ti, 54^{54}Fe(d,pd,p)55^{55}Fe, and 61^{61}Ni(d,pd,p)62^{62}Ni are shown in Refs. [33, 34, 35]. They provide direct information on the angular momentum, ll, transfer and the involved single-particle levels. Sample position spectra measured with the delay lines are also shown in Refs. [33, 34, 35]. As the energy resolution depends on the solid-angle acceptance, target thickness and beam-spot size, it may vary from experiment to experiment. In standard operation and with a global kinematic correction, a FWHM of 30-50 keV is routinely achieved. This resolution can be improved further with position-dependent offline corrections.

Figure 5. Particle identification with the SE-SPS focal-plane detector. A 16-MeV deuteron beam impinged onto a self-supporting 413-μg/cm2\mu\mathrm{g}/\mathrm{cm}^{2} 49Ti{}^{49}\mathrm{Ti} target. Four particle groups corresponding to protons, deuterons, tritons, and alpha particles can be clearly distinguished. The magnetic field of the SE-SPS was set to 8.8 kG and the gas pressure in the focal-plane detector was 160 Torr.

New scattering chamber and general setup design

A new scattering chamber for particle-γ coincidence experiments was designed and constructed at FSU. The 8-inch-diameter chamber is made out of aluminum, features 0.2-inch thin walls, the possibility to shield the Faraday cup (beam dump) and to evacuate the target ladder separately. In order to further reduce beam-induced γ-ray background coming from the Faraday cup, the latter can be shielded with lead. The front piece can be adjusted to the needs of specific experiments, i.e., the scattering angle can be changed by using a different front piece. The initial version has a port to the SE-SPS at ∼37\sim37 degrees (measured clockwise relative to the beam axis), a zero-degree port with a Faraday cup, and an additional port for an optional silicon beam-monitor detector. Each chamber-detector distance can be adjusted. For all detectors, the closest distance to the target is 4.5 inches. The adjustable distance of each detector to the chamber allows, in principal, for the addition of shields and attenuators if needed. Figure 6 shows the CeBrA demonstrator and scattering chamber in front of the FSU SE-SPS for the two different configurations, which were used for the (d,pγd,p\gamma) experiments featured below.

The first five CeBrA detectors around the aluminum scattering chamber at the FSU SE-SPS

Figure 6. The first five CeBrA detectors at the FSU SE-SPS around the newly built aluminum scattering chamber. Currently, four 2″ × 2″ and one 3″ × 4″ CeBr3_3 scintillators are available for γ\gamma-ray detection. (Top) Configuration for the 49Ti(d,pγ)50Ti{}^{49}\mathrm{Ti}(d,p\gamma){}^{50}\mathrm{Ti} and 61Ni(d,pγ)62Ni{}^{61}\mathrm{Ni}(d,p\gamma){}^{62}\mathrm{Ni} experiments. (Bottom) Configuration for the 52Cr(d,pγ)53Cr{}^{52}\mathrm{Cr}(d,p\gamma){}^{53}\mathrm{Cr} and 34S(d,pγ)35S{}^{34}\mathrm{S}(d,p\gamma){}^{35}\mathrm{S} experiments. The SE-SPS and its pole faces can be seen to the right of the CeBrA scattering chamber. The entrance to the SE-SPS with its slit box is behind the green gate valve which can be seen in the photos.

Gain stability of CeBr3 detectors at the SE-SPS

With the CeBr3_3 detectors positioned around the CeBrA scattering chamber, we explored the gain stability of the detectors, aiming to understand the potential impact of SE-SPS fringe fields on the PMTs during experiments. The spectrograph was set to a magnetic field strength of 8.6 kG and the CeBr3_3 detectors were calibrated using a 60^{60}Co standard calibration source after the first hour-long run (corresponding to hour 0 in Figure 7). This energy calibration was then consistently applied to the data collected in subsequent runs and not changed in order to identify possible gain shifts. As illustrated in Figure 7, a small initial shift of approximately 2 keV is observed after the first run. Nevertheless, following this initial shift, the PMT gain exhibited predominantly stable behavior throughout the remaining data collection. Given the energy resolution of ∼3\sim3% for the 2′′×2′′2^{\prime\prime} \times2^{\prime\prime} CeBr3_3 detectors at these γ\gamma-ray energies, we conclude that this level of gain shift is not significant and can be easily corrected for offline, which we successfully did for the (d,pγ)(d,p\gamma) experiments discussed below.

Figure 7. Gain stability study for a 2′′×2′′2^{\prime\prime} \times2^{\prime\prime} CeBr3_3 detector using the 1173-keV and 1332-keV γ-ray transitions of a 60^{60}Co standard calibration source. The detector was positioned around the CeBrA scattering chamber in front of the SE-SPS with the magnetic field set to 8.6 kG (see Figure 6). See text for discussion.

Full-energy peak (FEP) efficiency of the CeBrA demonstrator

Several factors affect the γ\gamma-ray detection efficiency of the CeBrA demonstrator. These include, e.g., the crystal size, the distance from the γ\gamma-ray source to the detector (minimum of 4.5 inches), and additional attenuating objects between the source and detector.

To determine the absolute full-energy peak (FEP) efficiency of the CeBrA demonstrator, we positioned a 152^{152}Eu standard calibration source of known activity at the center of the CeBrA scattering chamber installed in front of the SE-SPS. A 56^{56}Co source of unknown activity was used to determine the absolute FEP efficiency of the CeBrA demonstrator up to Eγ=3.5E_\gamma= 3.5 MeV by scaling the low-energy data to the absolute efficiencies measured with the 152^{152}Eu source. As an example, the measured FEP efficiencies for one 2′′×2′′2^{\prime\prime} \times2^{\prime\prime} and the 3′′×4′′3^{\prime\prime} \times4^{\prime\prime} CeBr3_3 detector of the CeBrA demonstrator are shown in Figure 8. They were obtained with the second configuration shown in Figure 6. A double exponential function was fitted to the experimental data. As can be seen from the residuals in Figure 8, the fit describes the data well up to Eγ=3.5E_\gamma= 3.5 MeV. For the two configurations, as shown in Figure 6, a 2′′×2′′2^{\prime\prime} \times2^{\prime\prime} detector has a typical FEP efficiency of ∼0.2\sim0.2% while the 3′′×4′′3^{\prime\prime} \times4^{\prime\prime} detector has an FEP efficiency of ∼0.7\sim0.7% at 1.3 MeV. The five-detector demonstrator array has a combined FEP efficiency of around 1.5% at 1.3 MeV. These quoted values depend of course on the distance from the chamber.

Figure 8. (Top) Absolute full-energy peak (FEP) efficiency for a 2′′×2′′2^{\prime\prime} \times2^{\prime\prime} and 3′′×4′′3^{\prime\prime} \times4^{\prime\prime} CeBr3_3 detector measured for the second CeBrA configuration shown in Figure 6 with a 152^{152}Eu standard calibration source of known activity and a 56^{56}Co source of unknown activity. In overlap regions, the 56^{56}Co data were scaled to the 152^{152}Eu data to obtain absolute FEP efficiencies up to Eγ=3.5E_\gamma= 3.5 MeV. A double exponential function was fitted to the data in both cases. The residuals between the fit and data are shown in the middle and bottom panel, respectively.

49^{49}Ti(d,pγ\gamma)50^{50}Ti and 61^{61}Ni(d,pγ\gamma)62^{62}Ni experiments: Coincidence timing, gating, and γ\gamma-decay intensities

For the first in-beam particle-γ\gamma coincidence tests, we used a continuous deuteron beam of beam energy Ed=16E_d = 16 MeV and set up an external trigger requiring a coincidence between the focal-plane scintillator and the CeBr3_3 detectors within a time window of Δt=±3 μ\Delta t = \pm3\ \mus. The configuration in the top panel of Figure 6 was used. With typical currents on target of 6 nA, the CeBr3_3 detectors were counting at rates of about 200 kcps, which is possible because of their extremely short signal pulses of ∼\sim200 ns without running into significant pile-up problems (see Figure 1 for an example). The coincidence timing spectrum is shown in Figure 9. Clear prompt coincidence peaks are observed on top of a flat random coincidence background. The three distinct peaks correspond to coincidences between γ\gamma rays detected with the CeBr3_3 detectors and light ions detected with the SE-SPS focal-plane detector, respectively. When a particle gate is set around the protons, only the corresponding coincidence peak remains (see Figure 9).

Figure 9. Example of time-difference spectrum between a 2′′×2′′2^{\prime\prime} \times2^{\prime\prime} CeBr3_3 detector of the CeBrA demonstrator and the scintillator of the SE-SPS focal-plane detector. Clear prompt coincidence peaks are observed, which belong to different particle groups, i.e., α\alpha particles, tritons, deuterons and protons (blue histogram). The centroid and FWHM values are as follows: protons (-674 ns, 2.6 ns), deuterons (-726 ns, 5.6 ns), tritons (-778 ns, 8.7 ns), and α\alpha particles (-727 ns, 4.9 ns). If the particle gate is set around the protons, only the coincidence between the protons and γ\gamma rays remains (red histogram). Differences are caused by the flight-time difference of the light-ion groups through the spectrograph+detector system.

We chose the 49^{49}Ti(d,pγ\gamma)50^{50}Ti reaction as a test case since the excitation spectrum is comparably simple at low excitation energies, since low-lying excited states are known to decay to different final states, and since 50^{50}Ti had previously been studied in (d,pγ\gamma) [36]. The particle-γ\gamma coincidence matrix for the 49^{49}Ti(d,p)50^{50}Ti reaction measured with the combined CeBrA+SE-SPS setup, and with the proton gate in the PID plot (see Figure 5) as well as a narrow timing gate of 4.5-ns width around the prompt peak (see Figure 9) applied is shown in Figure 10. Different features including diagonal bands corresponding to γ\gamma-ray decays leading to different final states can be clearly identified. A 49^{49}Ti contaminant originating from a 48^{48}Ti target contaminant is also identified. Such a contaminant would be missed in particle-singles experiments. A state at the corresponding energy is indeed listed in the NNDC database [26]. The inset of Figure 10 also shows a γ\gamma-ray spectrum obtained when an excitation-energy gate with a width of ∼130\sim130 keV is set around the 4880-keV excited state. This example highlights the power and sensitivity of particle-γ\gamma coincidences with the SE-SPS and γ\gamma-ray detectors as only γ\gamma rays originating from the corresponding γ\gamma-decay cascade are observed. The statistics shown here were obtained in 48 hours. During that time, ∼69000\sim69000 protons were detected with the focal-plane detector for the 4880-keV state. With the prompt timing gate applied, 6400 of these protons were detected in coincidence with γ\gamma rays. The coincident γ\gamma rays are shown in Figure 10 (see yy-axis projection).

Figure 10. Particle-γ\gamma coincidence matrix for 49^{49}Ti(d,pγd,p\gamma)50^{50}Ti. A narrow coincidence condition around the prompt proton-γ\gamma coincidence peak shown in Figure 9 was applied. Diagonals corresponding to γ\gamma-ray decays leading to different final excited states can be observed. The intercept with the xx-axis specifies the excitation energy of that final state. The yy-projection shows an example for a γ\gamma-ray spectrum when gated on an excitation energy of Ex=4880E_x = 4880 keV (vertical gate). Only γ\gamma rays originating from the corresponding decay cascade are observed.

For the 4880-keV (Jπ=5+J^\pi= 5^+) state, γ\gamma-decay intensities

of Iγ=2.1(2)I_\gamma= 2.1(2) for the 734-keV, 5+→4+5^+ \rightarrow4^+ transition, 8(2) for the 1682-keV, 5+→61+5^+ \rightarrow6_1^+ transition, and 100(6) for the 2205-keV, 5+→41+5^+ \rightarrow4_1^+ transition are adopted [26]. We determined an upper limit of Iγ≤15I_\gamma\le15 for the 734-keV, 5+→4+5^+ \rightarrow4^+ transition, and γ\gamma-decay intensities of 24(7) for the 1682-keV, 5+→61+5^+ \rightarrow6_1^+ transition and 100(11) for the 2205-keV, 5+→41+5^+ \rightarrow4_1^+ transition. As our γ\gamma-decay intensity for the 1682-keV transition deviates from the adopted value, we note that intensities of 22(3) and 14 were reported for this γ\gamma-decay branch following the 50^{50}Sc β−\beta^- decay [37] and the (d,pγ)(d,p\gamma) reaction [36], respectively. These intensities are in agreement with our new data. We also verified that the yield for the 1682-keV, 5+→61+5^+ \rightarrow6_1^+ transition is consistent with the number of counts observed for the 524-keV, 6+→4+6^{+}\rightarrow4^{+} transition when an excitation gate of 4880 keV is set.

Another example for the power of particle-γ\gamma coincidences with high-resolution magnetic spectrographs is shown in Figure 11. In this case, diagonal gates (as also shown in Figure 10) either requiring direct γ\gamma-ray decays to the ground or 21+2^{+}_{1} state are applied. As can be seen, different excited states populated in 61^{61}Ni(d,p)62(d,p)^{62}Ni and detected with the focal-plane detector can be picked up this way. While in the ground-state diagonal gate we primarily observe states with spin-parity assignment Jπ=1+,2+J^{\pi}=1^{+},2^{+}, also Jπ=3+J^{\pi}=3^{+} and 4+4^{+} states are observed when selecting γ\gamma decays which lead to the 1173-keV, Jπ=21+J^{\pi}=2^{+}_{1} state. This gating technique can provide important complementary information for better constraining spin-parity assignments and identifying which states were populated in a specific nuclear reaction. The 61^{61}Ni(d,pγ)62(d,p\gamma)^{62}Ni test experiment ran for roughly 61 hours.

Figure 11. Particle-γ\gamma coincidences measured in 61^{61}Ni(d,pγd,p\gamma)62^{62}Ni. (Top) Focal-plane (FP) spectrum if any coincident γ\gamma-ray was detected. (Middle) FP spectrum if γ\gamma-ray transition led directly to the ground state. (Bottom) FP spectrum if γ\gamma-ray transition led directly to the 2+2^+ state. States are marked with their excitation energies and adopted spin-parity assignment. For illustrative purposes, only the energy region between 700 keV and 4200 keV of the focal-plane spectrum is shown. See text for further discussion.

52^{52}Cr(d,pγ)53(d,p\gamma)^{53}Cr and 34^{34}S(d,pγ)35(d,p\gamma)^{35}S experiments: Proton-γ\gamma angular correlations and lifetime determination

For the second set of in-beam particle-γ\gamma coincidence tests, the CeBr3_3 detectors were rearranged to be in the same plane (ϕγ=0∘\phi_{\gamma}=0^{\circ}) relative to the beam axis to measure particle-γ\gamma angular correlations. The 2′′×2′′2''\times2''

CeBr3_3 detectors were placed at θγ=96(14)∘\theta_{\gamma}=96(14)^{\circ}, 211(14)∘211(14)^{\circ}, 241(14)∘241(14)^{\circ}, and 271(10)∘271(10)^{\circ}, and the 3′′×4′′3''\times4'' CeBr3_3 detector at θγ=141(22)∘\theta_{\gamma}=141(22)^{\circ} relative to the beam axis. The port from the scattering chamber to the SE-SPS was fixed at θSE−SPS=37∘\theta_{\mathrm{SE-SPS}}=37^{\circ}. All angles are measured clockwise relative to the beam axis. Also for this set of experiments, a 16 MeV deuterium beam was used and an external trigger was set up requiring a coincidence between the focal-plane scintillator and the CeBr3_3 detectors within a time window of Δt=±3 μs\Delta t=\pm3\,\mu\mathrm{s}.

For the 52^{52}Cr(d,pγ)53(d,p\gamma)^{53}Cr experiment, a target of 300-μg/cm2\mu\mathrm{g}/\mathrm{cm}^{2} natural Cr evaporated onto a 20-μg/cm2\mu\mathrm{g}/\mathrm{cm}^{2} thick backing of natural Carbon was used; 52^{52}Cr has a natural abundance of 83.8%. The particle-γ\gamma coincidence matrix is shown in Figure 12. By applying gates in the corresponding matrix for the individual CeBrA detectors and, hence, selecting the excited state of interest, the proton-γ\gamma angular correlations shown in Figure 13 were obtained. In addition, predictions from combined Adiabatic Distorted Wave Approximation (ADWA) calculations with chuck3 [38] yielding scattering amplitudes and angcor [39] calculations using these scattering amplitudes to generate the angular correlations are shown in Figure 13. These predictions (lines) were scaled to data by minimizing the residuals using the experimental uncertainties as weights. All theoretical proton-γ\gamma angular correlations were averaged over the solid-angle acceptance ΔΩ=4.6\Delta\Omega= 4.6 msr of the SE-SPS used in our experiments.

Figure 12. Particle-γ\gamma coincidence matrix for 52^{52}Cr(d,pγ)53(d,p\gamma)^{53}Cr. Also shown are diagonals on which γ\gamma decays of excited states leading to specific final states of 53^{53}Cr can be identified. The intercept with the xx-axis specifies the excitation energy of that final state.

Figure 13. Proton-γ\gamma angular correlations measured for excited states of 53^{53}Cr via 52^{52}Cr(d,pγ)53(d,p\gamma)^{53}Cr (symbols). Excitation energies ExE_x of the states, the γ\gamma-ray energy EγE_{\gamma} of the transition, as well as the spin-parity assignments JπJ^{\pi} of the states involved are specified. In (c) and (d), the primary 2417-keV, 9/2+→7/2−9/2^{+}\rightarrow7/2^{-} transition, depopulating the 3707-keV level, as well as the secondary 1290-keV, 7/2−→3/2−7/2^{-}\rightarrow3/2^{-} transition are shown, respectively. In addition, predictions from combined ADWA calculations with CHUCK3 [38] yielding scattering amplitudes and ANGCOR [39] calculations using these scattering amplitudes to generate the angular correlations are shown for each transition (lines). In panels (a)-(d), the dashed lines correspond to predictions when using the adopted multipole mixing ratios [26], while solid lines used different multipole mixing ratios. See text for further discussion.

For the 1006-keV, 5/21−→3/21−5/2^{-}_{1} \to3/2^{-}_{1} transition, we found that the experimentally measured angular correlation is best described when using a multipole mixing ratio of δ≈−0.58\delta\approx-0.58. Even though similar in magnitude, the absolute value is different from the previously reported values of δ=+0.36(2)\delta= +0.36(2) from 50Ti(α,n)^{50}\mathrm{Ti}(\alpha,n) [40] and δ=+0.80(6)\delta= +0.80(6) from Coulomb excitation [41]. For completeness, we added the angular correlation predicted with the adopted multipole mixing ratio of δ=+0.36(2)\delta= +0.36(2) [26] [see dashed line Figure 13 (a)], which clearly does not describe our data. For the 2320-keV, 3/22−→3/21−3/2^{-}_{2} \to3/2^{-}_{1}, we kept the adopted multipole mixing ratio of δ=−0.11(3)\delta= -0.11(3) [26] as it described our data reasonably well. A previous (d,pγ)(d,p\gamma) experiments reported a multipole mixing ratio of δ=0.00−0.09+0.04\delta= 0.00^{+0.04}_{-0.09} for the primary 2417-keV, 9/2+→7/2−9/2^{+} \to7/2^{-} transition from the 3707-keV state [42]. We found that our measured angular distribution is best described with a multipole mixing ratio of δ≈0.27\delta\approx0.27. Also for this transition, we added the predictions when using the multipole mixing ratio of δ=0.00\delta= 0.00 as inferred from the previous (d,pγ)(d,p\gamma) experiment [42] to Figure 13 (c).

We studied the secondary 1290-keV, 7/21−→3/21−7/2^{-}_{1} \to3/2^{-}_{1} transition after the γ\gamma decay of the 3707-keV level as well. This proton-γ\gamma angular correlation is shown in Figure 13 (d). It is well described when using a multipole mixing ratio of δ≈0.17\delta\approx0.17 [solid line in Figure 13 (d)]. The currently adopted value from a Coulomb-excitation experiment is δ=0.072(6)\delta= 0.072(6) [26, 41], which also leads to a fair description of our data. Note that different from other experiments, we can exclude feeding contributions due to our selective prompt-timing and excitation-energy gates.

In addition to establishing particle-γ\gamma coincidences and first proton-γ\gamma angular correlations with CeBrA and the SE-SPS, we studied the fast-timing capabilities of the combined setup to determine nuclear level lifetimes. The idea is to set a direct excitation-energy gate with the SE-SPS on the state whose lifetime is to be determined, which excludes any feeding. In addition, we do not have to pay a “γ\gamma-ray detection efficiency penalty” when choosing a feeding transition to select a specific γ\gamma-decay cascade and when wanting to exclude side-feeding contributions as done in, e.g., Ref. [43].

Employing the relative timing between the focal-plane scintillator and the CeBrA demonstrator, we determined a lifetime of 1.7(3) ns for the 1991-keV state of 35S^{35}\mathrm{S} after being populated through the 34S(d,p)^{34}\mathrm{S}(d,p) reaction [see Figure 14 (a)-(Figure 14c)]. To extract the lifetime, we used the convolution method (see also Figure 14). The lifetimes determined with the 2′′×2′′2'' \times2'' detectors and with the 3′′×4′′3'' \times4'' detector, respectively, are consistent. A Gaussian distribution was fitted to the data to illustrate the asymmetry in the tail, which is caused by the lifetime of the 1991-keV state (see Figure 14). To further illustrate the influence of a lifetime on the time-difference spectrum, we also studied the 2348-keV state of 35S^{35}\mathrm{S}. The 2348-keV state has a much shorter lifetime of 1.2(2) ps [26]. Consequently, we expect no pronounced tail in the time-difference spectrum. The comparison of Figure 14 (d) to Figure 14 (a) - (Figure 14c) clearly showcases that this is the case. We want to point out that our lifetime for the 1991-keV state is in agreement with the adopted value of 1.47(7) ns [26, 44] and that our measurement marks only the second measurement of the 1991-keV state’s lifetime so far.

Figure 14. Time-difference spectra of CeBr3_3 detectors and the scintillator of the SE-SPS focal-plane detector. (a) 2′′×2′′2'' \times2'' CeBr3_3 detectors, (b) 3′′×4′′3'' \times4'' CeBr3_3 detector, (c) entire CeBrA demonstrator for the 1991-keV state of 35S^{35}\mathrm{S}, and (d) for the 2348-keV state of 35S^{35}\mathrm{S}. The lifetime of the 1991-keV state determined using the convolution method and the different detector combinations is shown in panels (a) through (c), respectively. No tail is observed in panel (d) indicative of a short lifetime of the 2348-keV state. See text for more details.

Summary and Outlook

In this article, we presented results on the energy and timing resolution of 2′′×2′′2^{\prime\prime} \times2^{\prime\prime} and 3′′×4′′3^{\prime\prime} \times4^{\prime\prime} CeBr3_3 detectors measured with a digital data acquisition system based on the CAEN V1725S digitizer with DPP-PSD firmware. We also reported on the subsequent commissioning experiments with the CeBrA demonstrator for particle-γ\gamma coincidence experiments at the Super-Enge Split-Pole Spectrograph of the John D. Fox Superconducting Linear Accelerator Laboratory at Florida State University, for which the same data acquisition was used.

The characterization efforts, presented in this article and using standard calibration sources for the measurements, focused on optimizing the energy and timing resolution of the CeBr3_3 detectors. At 1.3 MeV, we achieved an energy resolution of 2.6% for the 2′′×2′′2^{\prime\prime} \times2^{\prime\prime} detectors and 2.8% for the 3′′×4′′3^{\prime\prime} \times4^{\prime\prime} detector. Using a 56^{56}Co source, we established that the energy resolution of the CeBr3_3 detectors evolves smoothly and follows the expected 1/Eγ1/\sqrt{E_\gamma} energy dependence up to Eγ=3.5E_\gamma= 3.5 MeV. The timing resolution varied between 500–590 ps for the 2′′×2′′2^{\prime\prime} \times2^{\prime\prime} CeBr3_3 detectors, while the 3′′×4′′3^{\prime\prime} \times4^{\prime\prime} CeBr3_3 detector exhibited a timing resolution of 750 ps measured relative to a 2′′×2′′2^{\prime\prime} \times2^{\prime\prime} detector. For these measurements, the two prompt γ\gamma transitions emitted in the β−\beta^- decay of 60^{60}Co were used. We also showed that nuclear level lifetimes in the hundreds of picoseconds range can be measured using the relative timing between the 2′′×2′′2^{\prime\prime} \times2^{\prime\prime} CeBr3_3 detectors. This would be challenging with an array consisting of only 3′′×4′′3^{\prime\prime} \times4^{\prime\prime} CeBr3_3 detectors due to their worse timing resolution. The 2′′×2′′2^{\prime\prime} \times2^{\prime\prime} detectors are a reasonable compromise between timing resolution and detection efficiency for γ\gamma rays with Eγ≤3E_\gamma\leq3 MeV compared to even smaller crystal sizes.

To commission the CeBrA demonstrator at the SE-SPS for particle-γ\gamma coincidence experiments, we performed four experiments; each one specifically chosen to showcase different capabilities of the array. The 49^{49}Ti(d,pγ)50(d,p\gamma)^{50}Ti reaction was, for instance, chosen as the excitation spectrum is comparably simple at low excitation energies, as low-lying excited states are known to decay to different final states, and as 50^{50}Ti had previously been studied in (d,pγ)(d,p\gamma) [36]. Besides establishing the excellent coincidence timing between the CeBrA detectors and the SE-SPS, we were able to study the γ\gamma decay of excited states of 50^{50}Ti to different final states using selective excitation energy gates. As an example, we discussed the γ\gamma decay of the 4880-keV, Jπ=5+J^\pi= 5^+ state. We showed that the γ\gamma-decay intensities, which we determined with the CeBrA demonstrator, were in excellent agreement with two of the three experiments which had previously studied the γ\gamma decay of this state.

The 61^{61}Ni(d,pγ)62(d,p\gamma)^{62}Ni reaction was chosen to highlight the capability of the combined array to select γ\gamma decays leading to specific final states with so-called diagonal gates and to pick up states with different spin and parity quantum numbers in that way. As an example, we showed that states with J=1,2J = 1, 2 can be picked up by selecting γ\gamma decays leading directly to the Jπ=0+J^\pi= 0^+ ground state of 62^{62}Ni even though several states might be overlapping in a certain excitation-energy range. Using the 52^{52}Cr(d,pγ)53(d,p\gamma)^{53}Cr reaction, we proved that very pronounced particle-γ\gamma angular correlations can already be measured with the limited detection efficiency of the CeBrA demonstrator. By performing combined calculations with the CHUCK3 and ANGCOR computer programs, we furthermore showed that we are sensitive to multipole mixing ratios. To test the fast-timing capabilities of the setup, we chose the 34^{34}S(d,pγ)35(d,p\gamma)^{35}S reaction. Using the relative timing between the SE-SPS focal plane scintillator and the CeBr3_3 detectors and setting a selective excitation energy gate, which excludes feeding, a lifetime of 1.7(3) ns was measured for the 1991-keV state. This lifetime is in good agreement with the adopted value of 1.47(7) ns and marks only the second measurement of this lifetime so far.

In summary, we commissioned the combined CeBrA and SE-SPS setup for particle-γ\gamma coincidence experiments. Thanks to the excellent resolution of the SE-SPS, narrow excitation energy gates can be set, which allow the selective study of the γ\gamma decay of excited states populated through light-ion induced nuclear reactions with the CeBr3_3 detectors of CeBrA. We demonstrated the capability of the combined setup to measure γ\gamma-decay branching ratios, particle-γ\gamma angular correlations, and nuclear level lifetimes using a set of carefully chosen (d,pγ)(d,p\gamma) test experiments. We also proved that, because of the fast recovery of the CeBr3_3 signals within a few hundred nanoseconds, (d,pγ)(d,p\gamma) experiments with CeBrA at the SE-SPS can be performed with typical currents of several nanoamperes on target, which would be challenging with High-Purity Germanium detectors in the proximity of the SE-SPS due to increased neutron and γ\gamma-ray background. The CeBr3_3 detectors run at rates of about 250 kcps with these currents on target and, during and after our experiments, we did not observe any loss in spectral quality. We have already tested that, e.g., (α,dγ)(\alpha,d\gamma) and (6Li,dγ)({}^{6}\mathrm{Li},d\gamma) experiments can be conducted with currents on target as high as several hundreds of nanoamperes and that the level of background radiation is much lower than in (d,pγ)(d,p\gamma). We will continue deploying the CeBrA demonstrator for detailed nuclear structure studies at the SE-SPS. However, we intend to add more detectors to CeBrA in order to increase its γ\gamma-ray detection efficiency and angular coverage in the near future. Specifically, we would like to add more large-volume CeBr3\mathrm{CeBr}_{3} crystals to increase the γ\gamma-ray detection efficiency at energies as high as those needed to study the γ\gamma decay of excited states up to the particle-separation thresholds. Such an upgrade would also enable particle-γ\gamma coincidence experiments for reactions with comparably small cross sections in a reasonable amount of time.

Acknowledgements

This work was supported by the National Science Foundation (NSF) under Grant No. PHY-2012522 (WoU-MMA: Studies of Nuclear Structure and Nuclear Astrophysics) and by Florida State University. We want to express our gratitude to Alexandra Gade and Dirk Weisshaar for lending us their LaBr3(Ce)\mathrm{LaBr}_{3}(\mathrm{Ce}) detectors. We also want to explicitly thank J. Aragon, P. Barber, R. Boisseau, B. Schmidt, R. Smith, and CAEN’s support staff for their support prior, during, and after our commissioning experiments. M.S. also wants to thank K.W. Kemper for many inspiring discussions. Part of the data was obtained during the 2023 Research Experience for Undergraduate Students (REU) at the John D. Fox Laboratory. The 34S{}^{34}\mathrm{S}, 47,49Ti{}^{47,49}\mathrm{Ti}, and 61Ni{}^{61}\mathrm{Ni} targets were provided by the Center for Accelerator Target Science at Argonne National Laboratory.

References

  1. [1]D. Weisshaar, D. Bazin, P. C. Bender, C. M. Campbell, F. Recchia, V. Bader, T. Baugher, J. Belarge, M. P. Carpenter, H. L. Crawford, M. Cromaz, B. Elman, P. Fallon, A. Forney, A. Gade, J. Harker, N. Kobayashi, C. Langer, T. Lauritsen, I. Y. Lee, A. Lemasson, B. Longfellow, E. Lunderberg, A. O. Macchiavelli, K. Miki, S. Momiyama, S. Noji, D. C. Radford, M. Scott, J. Sethi, S. R. Stroberg, C. Sullivan, R. Titus, A. Wiens, S. Williams, K. Wimmer, and S. Zhu, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 847, 187 (2017).
  2. [2]W. F. Mueller, J. A. Church, T. Glasmacher, D. Gutknecht, G. Hackman, P. G. Hansen, Z. Hu, K. L. Miller, and P. Quirin, Nucl. Instr. and Meth. A 466, 492 (2001).
  3. [3]D. Weisshaar, A. Gade, T. Glasmacher, G. Grinyer, D. Bazin, P. Adrich, T. Baugher, J. Cook, C. Diget, S. McDaniel, A. Ratkiewicz, K. Siwek, and K. Walsh, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 624, 615 (2010).
  4. [4]A. Gade and B. M. Sherrill, Physica Scripta 91, 053003 (2016).
  5. [5]S. Takeuchi, T. Motobayashi, Y. Togano, M. Matsushita, N. Aoi, K. Demichi, H. Hasegawa, and H. Murakami, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 763, 596 (2014).
  6. [6]D. Savran, A. van den Berg, M. Harakeh, K. Ramspeck, H. Wörtche, and A. Zilges, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 564, 267 (2006).
  7. [7]Clover Array Gamma-ray spectrometer at RCNP/RIBF for Advanced research CAGRA, https://www.rcnp.osaka-u.ac.jp/ jp/Divisionns/np1-a/CAGRA/ (2022).
  8. [8]BaGeL (Ball of Germanium and LaBr detectors) array at K600 magnetic spectrograph of iThemba Labs, https://tlabs.ac.za/the-bagel-array-in-action/ (2019).
  9. [9]F. Quarati, P. Dorenbos, J. van der Biezen, A. Owens, M. Selle, L. Parthier, and P. Schootanus, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 729, 596 (2013).
  10. [10]L. Fraile, H. Mach, V. Bedia, B. Olaizola, V. Pazy, E. Picado, and J. Udías, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 701, 235 (2013).
  11. [11]F. Quarati, M. Alekhim, K. Krämer, and P. Dorenbos, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 735, 655 (2014).
  12. [12]Berkeley Nucleonics Corporation, https://www.berkeleynucleonics.com/sites/default/files/products/resources/performance_of_cebr3_-_white_paper.pdf (2019).
  13. [13]Berkeley Nucleonics Corporation, https://www.berkeleynucleonics.com/cerium-bromide (2023).
  14. [14]J. Qin, C. Lai, J. Xiao, X. Lu, T. Zhu, R. Liu, and B. Ye, Radiation Detection Technology and Methods 4, 327 (2020).
  15. [15]A. Naqvi, F. Khiari, F. Liadi, K. ur Rehman, and A. Isab, Applied Radiation and Isotopes 114, 50 (2016).
  16. [16]M. Kaburagi, K. Shimazoe, M. Kato, T. Kurosawa, K. Kamada, K. J. Kim, M. Yoshino, Y. Shoji, A. Yoshikawa, H. Takahashi, and T. Torii, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 988, 164900 (2021).
  17. [17]P. N. Peplowski, Z. W. Yokley, J. T. Wilson, and R. S. Miller, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 1029, 166396 (2022).
  18. [18]S. Aogaki, D. Balabanski, R. Borcea, P. Constantin, C. Costache, M. Cucicu, A. Kuoğlu, C. Mihai, R. Mihai, L. Stan, P.-A. Söderström, D. Testov, A. Turturică, S. Ujeniuc, S. Adachi, F. Camera, G. Ciocan, F. Crespi, N. Florea, Y. Fujikawa, T. Furuno, E. Gamba, R. Gutoiu, T. Kawabata, N. Mărginеan, B. Million, C. Neascu, D. Nichita, R. Niina, S. Okamoto, H. Pai, A. Pappalardo, K. Sakanashi, A. Tamii, C. Ur, and O. Wieland, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment , 166828 (2023).
  19. [19]A. D. Giovanni, L. Manenti, F. Alkhouri, L. Alkindi, A. Al-Mannaei, A. A. Qasim, M. Benabdеrrahmane, G. Bruno, V. Conicella, O. Fawaz, P. Marpu, P. Panicker, C. Pittori, M. Roberts, T. Vu, and F. Arneodo, Journal of Instrumentation 14, P09017 (2019).
  20. [20]Advantech UK, https://www.advantech-uk.co.uk/cebr3.html (2023).
  21. [21]CAEN S.p.A., V1725/V1725S 16/8 Channel 14-bit 250 MS/s Digitizer, https://www.caen.it (2023).
  22. [22]CAEN S.p.A., Digital Pulse Processing for Charge Integration and Pulse Shape Discrimination (DPP-PSD) Firmware, https://www.caen.it/products/dpp-psd/ (2023).
  23. [23]CAEN S.p.A., Application Note AN6872, Energy and Timing characterization of two CeBr₃ detectors with a DT5730 digitizer and ComPASS, https://www.caen.it/support-services/documentation-area/?documentbyname=AN6872&type=all-categories (2019).
  24. [24]B. Longfellow, P. Bender, J. Belarge, A. Gade, and D. Weisshaar, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 916, 141 (2019).
  25. [25]V. Vedia, H. Mach, L. Fraile, J. Uldás, and S. Lalkovski, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 795, 144 (2015).
  26. [26]ENSDF, NNDC Online Data Service, ENSDF database, http://www.nndc.bnl.gov/ensdf/ (2023).
  27. [27]C. C. Dey, B. K. Sinha, R. Bhattacharya, and S. K. Basu, Phys. Rev. C 44, 2213 (1991).
  28. [28]Regis, Jean-Marc, “Fast Timing with LaBr₃(Ce) Scintillators and the Mirror Symmetric Centroid Difference Method”, PhD thesis, Universität zu Köln. http://kups.ub.uni-koeln.de/id/eprint/4290 (2011).
  29. [29]H. A. Enge, Nuclear Instruments and Methods 162, 161 (1979).
  30. [30]J. Spencer and H. Enge, Nuclear Instruments and Methods 49, 181 (1967).
  31. [31]E. Good, B. Sudarsan, K. Macon, C. Deibel, L. Baby, J. Blackmon, C. Benetti, J. Esparza, N. Gerken, K. Hanselman, G. McCann, A. Morelock, J. Perello, K. Pham, E. Rubino, E. Temanson, and I. Wiedenhöver, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 1003, 165299 (2021).
  32. [32]Good, Erin Courtney, “A Study of ²⁶Al(p, γ)²⁷Si with the Silicon Array for Branching Ratio Experiments (SABRE)”. LSU Doctoral Dissertations. 5402. https://digitalcommons.lsu.edu/gradschool_dissertations/5402 (2020).DOI
  33. [33]L. A. Riley, J. M. Nebel-Crosson, K. T. Macon, G. W. McCann, L. T. Baby, D. Caussyn, P. D. Cottle, J. Esparza, K. Hanselman, K. W. Kemper, E. Wiedenhöver, Phys. Rev. C 103, 064309 (2021).
  34. [34]L. A. Riley, L. C. S. Hay, L. T. Baby, A. L. Conley, P. D. Cottle, J. Esparza, K. Hanselman, B. Kelly, K. W. Kemper, K. T. Macon, G. W. McCann, M. W. Quirin, R. Renom, R. L. Saunders, M. Spieker, and I. Wiedenhöver, Phys. Rev. C 106, 064308 (2022).
  35. [35]M. Spieker, L. T. Baby, A. L. Conley, B. Kelly, M. Mü̈scher, R. Renom, T. Schüttler, and A. Zilges, Phys. Rev. C 108, 014311 (2023).
  36. [36]P. Sona, P. A. Mando, and N. Taccetti, Journal of Physics G: Nuclear Physics 10, 833 (1984).
  37. [37]D. E. Alburger, E. K. Warburton, and B. A. Brown, Phys. Rev. C 30, 1005 (1984).
  38. [38]P. D. Kunz and J. R. Comfort, program CHUCK3 , extended version (unpublished) (1978).
  39. [39]M. N. Harakeh and L. W. Put, program ANGCOR , KVI internal report 67i, (unpublished) (1979).
  40. [40]W. Gullholmer and Z. Sawa, Nuclear Physics A 204, 561 (1973).
  41. [41]P. Patrawale and R. Kulkarni, Journal of Physics G: Nuclear Physics 3, 1245 (1977).
  42. [42]T. Carola, W. Olsen, D. Sheppard, B. Sowerby, and P. Twin, Nuclear Physics A 144, 53 (1970).
  43. [43]A. Harter, A. Esmayzadeh, L. Knafla, C. Fransen, F. v. Spee, J. Jolie, M. Ley, V. Karayonchev, J. Fischer, and A. Pfeil, Phys. Rev. C 108, 024305 (2023).
  44. [44]F. W. Prosser and G. I. Harris, Phys. Rev. C 4, 1611 (1971).

Paper details

vlnc:W_kvxjwvv3
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 0

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents