WorksPhysics and Astronomy
The Position Resolution of a Charged Particle Hodoscope Consisting of Triangular Scintillator Counters
Abstract
Hodoscopes consisting of triangular counters with embedded wavelength shifting fibers are becoming more popular as they are relatively inexpensive, are easily fabricated, need no cooling systems, employ low-cost photodetectors, require only modest voltages, and perhaps most importantly, have good position resolution. Through interpolation of the light yields between adjacent counters, position resolutions that are typically an order of magnitude better than the counter separation can be obtained. Here, after a brief explanation of how the interpolation is done to improve the position resolution, we derive an approximate expressions for the uncertainty in the interpolated and positions as a function of the impact position of the charged particle.
Introduction
Hodoscopes consisting of arrays of triangular scintillator counters are becoming increasingly popular due to their modest cost, ease of fabrication, ease of operation, and their ability to operate in harsh environments. More importantly, position resolutions better than one-tenth of the distance between the triangle centers have been achieved (see Refs. [1, 2, 3, 4, 5, 6, 7], for example). We first derive the simple expressions that give the and coordinates of a charged particle going through a plane of triangular scintillator counters by interpolation of the charged particle path lengths through the adjacent counters using the relative light yields in each counter. We then derive an approximate expression of the uncertainties in the positions using Poisson estimates for the light yield distributions.
Determining the and Coordinates
We derive below the and positions found by interpolation of the light yields in the adjacent counters shown in Figure 1 and Figure 2 below. The results for the interpolated - and -coordinates are:

Figure 1. The counter geometry showing a charged track (in blue) traversing the inverted counter to the left of the center (upright) counter.

Figure 2. The counter geometry showing a charged track (in blue) traversing the inverted counter to the right of the center (upright) counter.
where the + sign in Eq. (1) refers to the case shown in Figure 1 where the leftmost triangle is inverted and the − sign in Eq. (1) refers to the case shown in Figure 2 where the leftmost triangle is upright. In both of the above equations is the triangle base width, is the triangle height, and and are the charged particle path lengths shown in Figure 1 and Figure 2.
To experimentally determine the and positions, we replace the path lengths and with their photoelectron yield proxies, and , to get:
where the approximate sign indicates the fact that and are imperfect measures of path lengths and .
Case 1: Charged Particle Traverses the Junction Between the Left and Center Counters
We derive Eq. (1) and Eq. (2) referring to the geometry shown in Figure 1 below. Each counter is an isosceles triangle of width and height . We assume that the charged particle’s incident angle is such that it only traverses no more than two counters, and we assume that the two counters have a perfect isosceles triangular shape. The origin of the coordinate system is at the midpoint of the interface between the two counters: in Figure 1. The coordinates of the point at which a charged particle passes the boundary between two counters is in Figure 1. The charged particle’s path (shown in blue in Figure 1), has a length in the left (inverted) counter and in the center (upright) counter.
We wish to find the best estimate of the coordinates of the point , relative to the origin of the coordinate system in Figure 1. We have from the geometry of similar triangles:
In addition, equals the height of the counter, or:
Setting these two above expressions for equal to one another, we have:
We can now solve for :
Does this equation make sense? If the path lengths and are equal, then , which is correct. If then , and if , then , both of which are correct.
Once the -coordinate is known (), the -coordinate can be found using the slope:
The -coordinate is then:
Does this equation make sense? If the path lengths and are equal, then , which is correct. If then , and if , then , both of which are correct.
Case 2: The Charged Particle Traverses the Junction Between the Center and Right Counters
This derivation proceeds exactly as that shown above for Case 1, and hence will not be repeated. The only difference is that the in going from the coordinate to the coordinate a minus sign appears as the slope of the junction between the two counters, as shown in Figure 2 is negative.
We have for the position in Figure 2:
exactly the same equation as found in Case 1 above.
Does this equation make sense? If the path lengths and are equal, then , which is correct. If then , and if , then , both of which are correct.
The -coordinate is:
The minus sign in front of Eq. (8) is the only difference between this value for and that from the previous section.
Does this equation make sense? If the path lengths and are equal, then , which is correct. If , then , and if , then , both of which are correct.
Angular Determination
We emphasize that the derivations of Eq. 1 and Eq. 2 are independent of the charged particle incident angle, as long as it does not traverse more than two counters. And, indeed, the incident angle cannot be determined by this method. Figure 3 shows two charged-particle tracks, and going through the left and right counter junctions at exactly the same and points, but at widely different angles. The point of this is to show that one cannot tell the angle from only one plane of triangular counters. Another plane is needed.

Figure 3. Two pairs of charged particles going through adjacent triangular counters. Each track of each pair has the same and coordinates, although their incident angles are quite different.
The Interpolated Position Uncertainty
We replace the distances traversed by the charged particles in the counters, and by their photoelectron yield proxies, and , respectively in Eq. (1). We have then
The uncertainty in as a function of the uncertainty in and :
We add the two uncertainties in quadrature to get the total uncertainty in :
We wish to estimate the uncertainty in parameters and . For charged particles going though a thin counter, this is given by a Landau distribution [8]. However, to simplify our derivation we assume the light yield follows a Poisson distribution in order to allow a simple estimation of their uncertainties:
Using these two values for and we find, using Eq. (11) in conjunction with Eqs. (9) and (10):
Finally,
The position uncertainty, , is easily determined to be:
Note that Eq. (12) and Eq. (13) are true for both Case 1 and Case 2 described above. Do these equations make sense? If or is 0 then the charged particle is going through the apex of one of the counters and or is zero.
At what value of is the uncertainty maximal? To find out we set the derivative of Eq. (12) equal to zero. We have, setting , where :
We also have a similar expression for the derivative of the position uncertainty:
Both equations are zero when , which happens when the charged particle crosses midway up the junction between the two counters where the path lengths through the adjacent counters are equal. If we let , then Eq. (12) reads:
In Figure 4 the -position uncertainty is plotted as a function of the position in units of the base width, , assuming a photoelectron yield of 100 PE/ (a light yield achieved by Ref. [9]). Figure 5 shows the resolution for a counter of 40 20 mm () and the same PE yield. The greatest uncertainty occurs when the charged particle crosses halfway up the junction between adjacent counters, and has a value of for a photoelectron yield of 5 PE/mm. The position resolution averaged over all incident values is .
Figure 4. The position uncertainty for normally incident particles versus the position along the base of the center triangular counter, from Eq. (12). Units are counter base width () and a light yield of 100 PE/ is assumed. The resolution is best at the corners of the center triangular counter and worst midway up its two sides.
Figure 5. The position uncertainty for normally incident particles versus the position along the base of the center triangular counter, from Eq. (12). The counter is 40 20 mm () and a light yield of 5 PE/mm is assumed. The resolution is best at the corners of the center triangular counter and worst midway up its two sides.
For a triangular counter of width 40 mm, such as the counter described in Ref. [9], that resolution is mm, using their measured photoelectron yield of 100 PE/. The worse resolution for such a counter is 1.0 mm.
Our result is a lower limit on the position uncertainty one expects from a real hodoscope. Real position resolutions are worse for several reasons, such as imperfections in the counter
geometry, electronics noise, and the fact that assuming a Poisson distribution for the photoelectron yield underestimates the tails in the real light yield distributions. A recent study of the position resolution of a hodoscope consisting of () counters with a light yield of (and using Eq. (1) to determine the position) shows a similar behavior in the position resolution as a function of the charged particle impact position as shown in Fig. 5 [9]. They find a maximum -position uncertainty of roughly 2 mm, about a factor of two worse than what we estimate here. However, with a toy Monte Carlo that uses a Landau+Gaussian fit to the measured light yield distribution, they find excellent agreement with the data.
References
- [1]M. Adams et al., “A new detector technique using triangular scintillating strips to measure the position of minimum ionizing particles,” Nucl. Instrum. Meth. A 378 (1996) 131, and P. Baringer et al., “Cosmic-ray tests of the DØ preshower detector,” Nucl. Instrum. Meth. A 469 (2001) 295.DOI
- [2]G. Ambrosi et al., “The MU-RAY project: Volcano radiography with cosmic-ray muons,” Nucl. Instrum. Meth. A 628 (2011) 120. A. Anastasio et al., “The MU-RAY experiment. An application of SiPM technology to the understanding of volcanic phenomena,” Nucl. Instrum. Meth. A 718 (2013) 134. A. Anastasio et al., “The MU-RAY detector for muon radiography of volcanoes,” Nucl. Instrum. Meth. A 732 (2013) 423,DOI
- [3]L. Aliaga et al., “Design, calibration, and performance of the MINERvA detector,” Nucl. Instrum. Meth. A 743 (2014) 130.DOI
- [4]S. Cecchini et al., “Test of scintillator bars coupled to Silicon Photomultipliers for a charged particle tracking device,” Nucl. Instrum. Meth. A 846 (2017) 1,DOI
- [5]G. Baccani et al., “The MIMA project. Design, construction and performances of a compact hodoscope for muon radiography applications in the context of archaeology and geophysical prospections,” JINST 13 (2018) P11001.DOI
- [6]P. Bernardini et al., “On the performances of a particle tracking detector based on triangular scintillator bars read out by silicon photomultipliers,” Nucl. Instrum. Meth. A 967 (2020) 163882,DOI
- [7]X. Luo et al., “Development and commissioning of a compact Cosmic Ray Muon imaging prototype,” Nucl. Instrum. Meth. A 1033 (2022) 166720.DOI
- [8]P. V. Vavilov, Sov. Phys. JETP 5, 749 (1957), (Zh. Eksp. Teor. Fiz. 32, 920 (1957)], L.D. Landau, J. Exp. Phys. (USSR) 8, 201 (1944).
- [9]“Position Resolution of a Scintillator Hodoscope Employing Triangular Counters with Embedded Wavelength Shifting Fibers,” E. Craig Dukes, Ralf Ehrlich, Daniel Lee, Sydney Roberts, Luke Watson, Alan Bross, Sten Hansen, and Paul Rubinov, arXiv:2608.10282 (2026).arxiv.org/abs/2608.10282

