betaFeedback

WorksPhysics and Astronomy

Thick-target Yield of 65^{65}Cu(α,n)68α,n)^{68}Ga Near Threshold and Implications for Nuclear Medicine, Deep Underground Detector Backgrounds, and Nucleosynthesis

Abstract

We report thick target yields of 65Cu(α,n)68Ga^{65}{\rm Cu}(α,n)^{68}{\rm Ga} from αα energies EαE_α==6.5–8~MeV measured via neutron-counting at the Edwards Accelerator Laboratory at Ohio University. Our results agree with prior results based on single-foil irradiations, while disagreeing with thick-target yields inferred from stacked-foil irradiations by up to an order of magnitude. Based on comparisons of our and prior measurements to Hauser-Feshbach calculations, we estimate the thick-target yield for 68Ga^{68}{\rm Ga} from EαE_α=14~MeV impinging on 100%-enriched copper (65Cu^{65}{\rm Cu}) is 161−24+5^{+5}_{-24}~MBq/μμAh (for He++^{++}), which is in agreement with the current IAEA estimate of 156~MBq/μμAh. At EαE_α==8~MeV, where radioimpurity-free production of 68Ga^{68}{\rm Ga} could be realized with a natural copper target, our yield estimate is nearly 4×\times lower than the IAEA estimate. We find that the 65Cu(α,n)^{65}{\rm Cu}(α,n) cross section estimates presently employed for neutrino and dark matter detector backgrounds and the 65Cu(α,n)^{65}{\rm Cu}(α,n) astrophysical reaction rate recently recommended for nucleosynthesis calculations are in agreement with our measurement results.

Graphical Abstract

![Thick-target Yield of 65Cu(α,n)68Ga^{65}\mathrm{Cu}(\alpha,n)^{68}\mathrm{Ga} Near Threshold. Upper panel: Yield [n/αn/\alpha] versus EαE_{\alpha} [MeV], with logarithmic yield axis from 10−1010^{-10} to 10−410^{-4} and energy ticks 7 through 14. Lower panel: Ratio To OMP3 Yield versus EαE_{\alpha} [MeV], with logarithmic ratio axis from 10−110^{-1} to 10. Labels: Aslam, IAEA, T7, T8, T1-6, Kamal, Kudryavtsev, Dmitriev, Roughton, Stelson, Hamad.]

Figure 7.

Highlights

  • New thick-target yields reported for 65Cu(α,n)68Ga^{65}\mathrm{Cu}(\alpha,n)^{68}\mathrm{Ga} from Eα=6.5−8E_{\alpha}=6.5-8 MeV based on neutron counting.

  • Yields agree with prior single-foil activation and neutron counting measurements, and are substantially smaller than estimates based on stacked-foil activation experiments.

  • Based on comparisons of Hauser-Feshbach calculations to this and previous measurements, we estimate the thick-target yield for 68Ga^{68}\mathrm{Ga} from Eα=14E_{\alpha}=14 MeV α\alpha-particles impinging on enriched copper (65Cu^{65}\mathrm{Cu}) is 161−24+5161^{+5}_{-24} MBq/μ\muAh (for He++^{++}), which is in agreement with the current IAEA estimate of 156 MBq/μ\muAh. Our yield estimate is nearly 4× lower than the IAEA estimate for Eα=8E_{\alpha}=8 MeV, where radioimpurity-free production of 68Ga^{68}\mathrm{Ga} could be achieved with a natural copper target.

  • 65Cu(α,n)^{65}\mathrm{Cu}(\alpha,n) cross section estimates presently employed for neutrino and dark matter detector backgrounds agree with the present results.

  • The astrophysical reaction rate corresponding to our recommended cross section is in agreement with rates calculated using a state-of-the-art α\alpha-optical potential employed in nucleosynthesis calculations.

Introduction

The nuclear reaction 65Cu(α,n)68Ga^{65}\mathrm{Cu}(\alpha,n)^{68}\mathrm{Ga} is of interest for a wide variety of applications, including nuclear medicine, neutrino and dark matter detection, and nuclear astrophysics [1, 2, 3, 4]. In nuclear medicine, this reaction is an avenue for production of the medical isotope 68Ga^{68}\mathrm{Ga}. In neutrino and dark matter detection, the presence of α\alpha-emitting actinides and copper components in detection equipment results in a background of massive neutral particles (neutrons) in deep underground detectors dedicated to detecting other neutral particles, namely neutrinos and dark matter [5]. In helium-rich astrophysical environments, 65Cu(α,n)^{65}\mathrm{Cu}(\alpha,n) is one reaction (of many) involved in nucleosynthesis of heavier elements.

68Ga^{68}\mathrm{Ga} medical isotope production has been of particular interest for the majority of past 65Cu(α,n)^{65}\mathrm{Cu}(\alpha,n) measurements. 68Ga^{68}\mathrm{Ga} is desirable for medical imaging and diagnostics as it is a positron emitter with a convenient half-life [6, 7]. When a high yield is desired, one promising route for 68Ga^{68}\mathrm{Ga} production is 65Cu(α,n)^{65}\mathrm{Cu}(\alpha,n), where maintaining α\alpha beam energies Eα<14E_{\alpha}<14 MeV avoids production of undesirable radioimpurities [8]. This energy regime overlaps with Eα≲8E_{\alpha}\lesssim8 MeV of interest for (α,n)(\alpha,n) backgrounds due to α\alpha-emitting actinides [9] and the near-threshold energies typically of interest for astrophysical reaction rates [10]. Eα=8E_{\alpha}=8 MeV is meanwhile of potential interest for medical isotope production with natural copper targets, as it avoids all radioisotope contamination [11].

A number of 65Cu(α,n)68Ga^{65}\mathrm{Cu}(\alpha,n)^{68}\mathrm{Ga} cross section and thick-target yield measurements have been performed to-date covering Eα<14E_{\alpha}<14 MeV, approaching the nuclear reaction threshold (6.139 MeV [12]) [4, 11, 13, 14, 15, 16, 17, 18, 19, 20]. All except for Refs. [4, 14] performed their measurements using the stacked-foil activation method with an α\alpha-beam from a cyclotron. These measurements generally start with large EαE_{\alpha}, such that the low-energy yields are derived from foils located deep within the stack. Several uncertainties in EαE_{\alpha} compound in such measurements [11]. The incident beam energy generally begins with a hundreds-of-keV uncertainty when produced by a cyclotron and is then degraded by energy loss through the foil-stack. Uncertainties in energy loss and energy and angular straggling, along with uncertainties in initial beam alignment, can readily compound to result in MeV-level errors.

Specific concerns with existing 65Cu(α,n)^{65}\mathrm{Cu}(\alpha,n) data include the following. The cross section data from Bryant et al. [13] are too-sparse near threshold to enable a thick-target yield calculation. Dmitriev [15] report data from previous measurements without specifying any experimental details. Bhardwaj et al. [16] report a single data-point with Eα<14E_{\alpha}<14 MeV with a large energy uncertainty. Levkovskij [17] report (unphysical) non-zero yields below threshold and have a large energy uncertainty. Bonesso et al. [18] report cross sections systematically much larger than all other datasets at which there is a common measurement energy, leading to their exclusion from IAEA evaluation of medical isotope production cross sections (along with Levkovskij [17] for the aforementioned reasons) [2]. Singh et al. [19] report a single data-point within Eα<14E_{\alpha}<14 MeV. The cross sections reported by Szelecsényi et al. [11] and Hermanne et al. [20] each have very large energy uncertainties, where the latter reports non-zero cross sections below threshold (due to the large energy uncertainty).

Various subsets of these data have been employed to estimate the medical isotope production yield for 65Cu(α,n)68Ga{}^{65}\mathrm{Cu}(\alpha,n){}^{68}\mathrm{Ga}. In general this involves obtaining a single-valued function for the nuclear reaction cross section and the stopping power of α\alpha-particles in copper. As the latter is relatively well known [21, 22], the former is of particular concern.

Smooth approximations for the 65Cu(α,n)68Ga{}^{65}\mathrm{Cu}(\alpha,n){}^{68}\mathrm{Ga} cross section for medical isotope production have been obtained in the following ways. The IAEA evaluation of Tárkányi et al. [2] performed a fit via a Padé approximation to the stacked-foil activation data of Refs. [11, 13, 16, 19, 20] (for Eα<14E_{\alpha}<14 MeV). Aslam et al. [8] fit the data of Refs. [11, 13, 14, 16, 17, 18, 19, 20] (for Eα<14E_{\alpha}<14 MeV) by normalizing Hauser-Feshbach [23] calculation results with third-order polynomials derived from fits to residuals from the Hauser-Feshbach calculations. Dmitriev [15] linearly interpolated the cross section data contained within their report. Kamal et al. [24] performed Hauser-Feshbach calculations and used the data of Ref. [20] as a benchmark by which to judge their results. Notably, none of the prior estimates leverage the single-foil irradiation data of Roughton et al. [4] and the one estimate that leverages the single-foil irradiation data of Stelson and McGowan [14] also includes a number of stacked-foil datasets (which may be problematic near threshold), thus minimizing the influence of this dataset.

The corresponding medical isotope production cross sections from these analyses vary considerably. At Eα=14E_{\alpha}=14 MeV for a 100%-enriched 65Cu{}^{65}\mathrm{Cu} target, the extreme estimates are 80 MBq/μ\muAh [15] and ∼\sim370 MBq/μ\muAh [24]. Intermediate estimates are 156 MBq/μ\muAh from the IAEA Charged-particle cross section database for medical radioisotope production2 [2] and 183 MBq/μ\muAh [8]. Meanwhile, Dmitriev [15] report an uncertainty of 10-16%, where the yield uncertainty implied from the evaluated cross section uncertainty of Tárkányi et al. [2] is of similar order when also considering typical stopping-power uncertainties. As such, current estimates of the 65Cu(α,n)68Ga{}^{65}\mathrm{Cu}(\alpha,n){}^{68}\mathrm{Ga} medical isotope production yield are significantly discrepant from one another.

In an effort to resolve these discrepancies, we performed thick-target yield measurements of 65Cu(α,n)68Ga{}^{65}\mathrm{Cu}(\alpha,n){}^{68}\mathrm{Ga} and compared our results and earlier single-foil irradiation results to Hauser-Feshbach calculations. Section 2 describes our experiment and analysis to obtain the thick-target yield. Section 3 presents the yield in comparison to previous results and Hauser-Feshbach calculations, in the context of 68Ga{}^{68}\mathrm{Ga} medical isotope production. Section 4 describes the inferred 65Cu(α,n)68Ga{}^{65}\mathrm{Cu}(\alpha,n){}^{68}\mathrm{Ga} cross section and implications for neutrino and dark matter detector backgrounds, as well as for astrophysical nucleosynthesis calculations. Section 5 provides conclusions.

Measurement and Analysis

Thick-target yield measurements were performed between Eα=6.533−7.996E_{\alpha}=6.533-7.996 MeV at the Edwards Accelerator Laboratory [25] using the 3{}^{3}HeBF3_3 HeBGB experiment set-up described in Refs. [26, 27] and shown in Figure 1 (PDF p. 5).

The HeBGB neutron detector

Figure 1 (PDF p. 5). The HeBGB neutron detector. A purple borated polyethylene box surrounds the polyethylene moderator, in which the 3He{}^{3}\mathrm{He} and BF3_3 proportional counters are embedded in a concentric ring configuration about the beam axis. A ladder drive enables quick change between targets located along the beam axis.

Helium ions were produced using an Alphatross ion source and accelerated with a 4.5 MV T-type tandem Pelletron, departing the 3{}^{3}HeBF3_3 support foil located within the accelerator terminal as He++^{++}. The beam was bent toward the 65∘65^\circ-right beamline of the large target room via the energy-calibrated 90∘90^\circ analyzing magnet. The beam energy is calibrated with 0.1% uncertainty using an NMR magnetometer on the field of the analyzing magnet. The beam energy resolution and tune-dependent energy variations (for a given NMR setting) are limited to being <0.2%<0.2\% by the 0.152-cm gap at the magnet exit. The beam passed through an 0.5-cm-diameter gold-plated collimator located approximately 48 cm upstream of the target location prior to entering the beam-pipe within HeBGB. This and all-other gold-plating referred to for the present measurement consisted of 99.95% purity 0.05-mm-thick gold foil from Avantor. The beam-current impinging on the set-up was integrated with 1% uncertainty for the beam-pipe within HeBGB, the target ladder, and, for collimator measurements, the downstream Faraday cup. Typical on-target beam currents were ∼\sim10–50 nA, corresponding to beam intensities of Iα∼1011I_{\alpha}\sim10^{11} pps.

The target consisted of the gold-plated ladder shown in Figure 2, mounted at the end of the drive labeled in Figure 1 (PDF p. 5). During tuning, the drive was adjusted such that the centrally-positioned gold-plated collimator was located along the beam axis. The beam was tuned in order to achieve a 0 nA current reading on the ladder, while maximizing current on the downstream Faraday cup. The drive was then adjusted such that the beam was centered on the upper target, an 0.8-mm-thick disk of oxygen-free copper with natural abundance manufactured by the Duke machine shop. To correct for the neutron background from carbon contamination, as described shortly, measurements (described in full in Ref. [9]) were also performed at each energy with the drive adjusted such that the beam was centered on the bottom target, 13C^{13}\mathrm{C} enriched to >99%>99\% evaporated onto a copper

Gold-plated target ladder with copper, collimator, and $^{13}\mathrm{C}$ targets

Figure 2. The gold-plated target ladder with copper, collimator, and 13C^{13}\mathrm{C} targets, from top to bottom.

substrate by Arizona Carbon Foil. Beam-on-target times ranged from approximately tmeas.=0.5t_{\mathrm{meas.}}=0.5–3 minutes for each target+EαE_{\alpha} combination.

NdetectedN_{\mathrm{detected}} neutrons were detected using 3He^{3}\mathrm{He} and BF3_3 proportional counters, from Baker Hughes and Reuter-Stokes, respectively, located within concentric rings about the beam axis, embedded within a block of ultra-high molecular-weight polyethylene from Trident Plastics, as shown in Figure 1 (PDF p. 5) and described in Ref. [26]. The polyethylene moderator was surrounded by a 2.54-cm-thick box of 5% borated high-density polyethylene from Professional Plastics to reduce external neutron background. The HeBGB neutron detection efficiency was η=7.5±1.2%\eta=7.5\pm1.2\%, as determined in Ref. [26], where HeBGB provides nearly 4π4\pi solid-angle coverage. The angular distribution of neutrons from 65Cu(α,n)^{65}\mathrm{Cu}(\alpha,n) was assumed to be isotropic, consistent with expectations for (α,n)(\alpha,n) reactions near-threshold on medium-mass nuclides [28, 29], and so angular-distribution corrections to the efficiency were not performed. A 60 Hz pulser was adjusted to provide a signal outside of the neutron spectrum in order to monitor the live-fraction flivef_{\mathrm{live}} of the data acquisition. As count rates were ≲200\lesssim200 n/s at all measurement energies, flive≈1f_{\mathrm{live}}\approx1.

The ambient neutron background was approximately 0.4 n/s. However, it was apparent that beam-induced background was more significant, given the non-zero yields we obtained for 65Cu(α,n)^{65}\mathrm{Cu}(\alpha,n) below threshold following ambient background subtraction. Similarly, subtraction of the yield measured when the beam was tuned through the target-ladder collimator was insufficient to remove the below-threshold non-zero yield. We observed that the below-threshold yield on the copper target closely matched the trend measured for the 13C^{13}\mathrm{C} target, once the latter was scaled down, as shown in Figure 3. We therefore attribute our neutron background NbackgroundN_{\mathrm{background}} to 13C^{13}\mathrm{C}-contamination on the copper target and apply this scaled-down yield as a background subtraction, to which we assign an uncertainty of 6×10−106 \times10^{-10} n/α\alpha (after accounting for detection efficiency). We do not consider the possibility of carbon build-up over time modifying the contamination level [30], since the target accumulated relatively small amount of beam charge at relatively low intensity and measurements were performed over the course of roughly one day. We note that the trend in the yield for the 13C{}^{13}\mathrm{C} target lacks the peak observed in the yield around Eα≈6.5E_{\alpha} \approx6.5 MeV when the beam was tuned through the collimator. As it is unknown whether the neutrons from the through-collimator measurements originate from the downstream Faraday cup or upstream beamline components, it is unknown whether this background peak would be present in the copper-target data. As such, it is possible that our 65Cu(α,n){}^{65}\mathrm{Cu}(\alpha,n) yields for the Eα≈6.5E_{\alpha} \approx6.5 and 6.66.6 MeV data points are somewhat overestimated.

Figure 3. Raw yield measured with the copper target (solid black circles) or collimator (solid gray squares) located at the beam axis. The measured 13C^{13}\mathrm{C} target yield has been scaled by an arbitrary factor (open red circles) to overlap the low-EαE_{\alpha} copper data. The vertical line indicates the 65Cu(α,n)^{65}\mathrm{Cu}(\alpha,n) threshold.

The measured thick-target yield was calculated as

Ymeas.=Ndetected−NbackgroundIαtmeas.ηflive(1)Y_{\mathrm{meas.}} = \frac{N_{\mathrm{detected}} - N_{\mathrm{background}}}{I_{\alpha}t_{\mathrm{meas.}}\eta f_{\mathrm{live}}} \tag*{(1)}

where we note that the conversion from beam current to beam intensity accounts for the doubly-ionized nature of the helium beam. The thick target yield uncertainty sources were 1–4% statistical, 1% beam current integration, 16% HeBGB efficiency, and ±6×10−10\pm6 \times10^{-10} n/α\alpha carbon background subtraction, all of which were summed in quadrature to arrive at a total yield uncertainty. Though our measurements were performed with a natural copper target, the thick-target yield of a pure 65Cu{}^{65}\mathrm{Cu} target is of interest. Therefore we divide our measured yields by the natural abundance fraction of 65Cu{}^{65}\mathrm{Cu}, 0.3085 [31].

Thick-Target Yield and Nuclear Medicine Implications

Our thick-target yield for 65Cu(α,n)68Ga{}^{65}\mathrm{Cu}(\alpha,n){}^{68}\mathrm{Ga} is reported in Table 1. In Figure 4, we compare our results to existing experimental thick-target yield data [4, 14] and the myriad of evaluations and estimates discussed in § 3. Within our covered energy range, we agree with both the activation data of Roughton et al. [4] and the neutron-counting data of Stelson and McGowan [14], though these two are in tension within their stated uncertainties. Only Tárkányi et al. [2] provide a yield estimate for medical isotope production within our measured energy range, which is approximately 3–6×\times our measured yield. This is likely due to the fact that the IAEA analysis focused on higher EαE_{\alpha} and fit to stacked-foil activation results, which struggle to provide accurate results at low energies, as described in § 3.

EαE_{\alpha} [MeV]dEαdE_{\alpha} [MeV]Yield [n/α\alpha]dYield [n/α\alpha]
6.5330.0141.98×10−91.98 \times10^{-9}9.28×10−109.28 \times10^{-10}
6.6420.0143.61×10−93.61 \times10^{-9}1.19×10−91.19 \times10^{-9}
6.8660.0157.39×10−97.39 \times10^{-9}1.79×10−91.79 \times10^{-9}
7.0570.0151.71×10−81.71 \times10^{-8}3.38×10−93.38 \times10^{-9}
7.1280.0152.17×10−82.17 \times10^{-8}4.12×10−94.12 \times10^{-9}
7.1500.0152.35×10−82.35 \times10^{-8}4.43×10−94.43 \times10^{-9}
7.1610.0152.54×10−82.54 \times10^{-8}4.74×10−94.74 \times10^{-9}
7.1710.0152.64×10−82.64 \times10^{-8}4.91×10−94.91 \times10^{-9}
7.1820.0152.75×10−82.75 \times10^{-8}5.08×10−95.08 \times10^{-9}
7.2040.0152.98×10−82.98 \times10^{-8}5.46×10−95.46 \times10^{-9}
7.2310.0153.23×10−83.23 \times10^{-8}5.85×10−95.85 \times10^{-9}
7.2810.0163.78×10−83.78 \times10^{-8}6.75×10−96.75 \times10^{-9}
7.3300.0164.10×10−84.10 \times10^{-8}7.27×10−97.27 \times10^{-9}
7.3790.0165.00×10−85.00 \times10^{-8}8.75×10−98.75 \times10^{-9}
7.4280.0165.63×10−85.63 \times10^{-8}9.79×10−99.79 \times10^{-9}
7.4770.0166.35×10−86.35 \times10^{-8}1.10×10−81.10 \times10^{-8}
7.5480.0167.45×10−87.45 \times10^{-8}1.27×10−81.27 \times10^{-8}
7.5970.0168.06×10−88.06 \times10^{-8}1.37×10−81.37 \times10^{-8}
7.6460.0169.46×10−89.46 \times10^{-8}1.60×10−81.60 \times10^{-8}
7.7010.0161.11×10−71.11 \times10^{-7}1.86×10−81.86 \times10^{-8}
7.7280.0161.11×10−71.11 \times10^{-7}1.85×10−81.85 \times10^{-8}
7.8260.0171.53×10−71.53 \times10^{-7}2.52×10−82.52 \times10^{-8}
7.9960.0172.10×10−72.10 \times10^{-7}3.44×10−83.44 \times10^{-8}

Table 1. Thick-target yield for 65Cu(α,n){}^{65}\mathrm{Cu}(\alpha,n) determined in this work.

Thick-target yield and ratio to the αOMP3 yield for $^{65}$Cu($\alpha,n$)$^{68}$Ga near threshold

Figure 4. (upper panel) Thick-target yield for 65^{65}Cu(α,n\alpha,n) from this work’s (Hamad) and prior experimental data [4, 14] along with several evaluations [2, 3, 8, 15, 24] and the Hauser-Feshbach calculations performed with α\alphaOMP 1–8 (T1–T8). The lower-panel shows the ratio of the upper panel data to the α\alphaOMP model 3 yield for ease of comparison.

In order to compare to medical isotope production estimates up to Eα=14E_{\alpha}=14 MeV, we performed Hauser-Feshbach calculations of 65Cu(α,n){}^{65}\mathrm{Cu}(\alpha,n) with Talys version 2.0 [32] for a variety of α\alpha-optical model potentials (α\alphaOMP) and calculated thick-target yields assuming the helium stopping power in copper from SRIM2013 [33]. Hauser-Feshbach calculations

of (α,n)(\alpha,n) reactions on medium-mass nuclides are generally considered to accurately predict experimental cross-sections within an order of magnitude [34], where the spread in predictions near threshold is predominantly due to the α\alphaOMP [35]. For the present case, we find <10%<10\% impact on the calculated 65Cu(α,n){}^{65}\mathrm{Cu}(\alpha,n) cross section when exploring nuclear level-density and neutron and proton optical potential model options available in Talys. Therefore, once anchored by experimental data, Hauser-Feshbach calculations are expected to provide an accurate representation of the energy trend in the 65Cu(α,n){}^{65}\mathrm{Cu}(\alpha,n) cross section (i.e. excitation function) and therefore extrapolation from our low EαE_{\alpha} dataset up to Eα=14E_{\alpha}=14 MeV.

Talys calculations were performed for α\alphaOMP models 1 through 8 [32], using default model parameters otherwise. We calculated the thick-target yield from the Hauser-Feshbach cross section σHF\sigma_{\mathrm{HF}} and stopping-power ϵ(E)\epsilon(E) via

Ycalc.=∫0EασHF(E)ϵ(E) dE(2)Y_{\mathrm{calc.}} = \int_{0}^{E_{\alpha}} \frac{\sigma_{\mathrm{HF}}(E)}{\epsilon(E)}\,\mathrm{d}E \tag*{(2)}

resulting in the yield curves shown in Figure 4. For ease of comparison, the lower-panel shows the ratio of all thick-target yields discussed in this work to the yield obtained with α\alphaOMP model 3, as this model selection best reproduces the experimental data. We note however that yields calculated using α\alphaOMP models 1–6 [32, 36, 37, 38] are all within one standard deviation of our Ymeas.Y_{\mathrm{meas.}} and are bounded by the thick-target yields of Stelson and McGowan [14] and Roughton et al. [4]. Meanwhile, yields calculated using

α\alphaOMP models 7 [39] and 8 [40] are clearly discrepant with the experimental data. In principle, these Ycalc.Y_{\mathrm{calc.}} have some uncertainty contribution from the choice of ϵ(E)\epsilon(E). In practice, the SRIM2013 ϵ(E)\epsilon(E) for Eα=6E_{\alpha}=6–14 MeV helium within copper is within 1% of all experimental data4 [41, 42], with the exception of a single data-point [43] that is discrepant by 6%, and within 1% of other commonly employed ϵ(E)\epsilon(E) theory estimates [44, 45]. Thus the ϵ(E)\epsilon(E) uncertainty is negligible in the present context.

At the lowest EαE_{\alpha} in Figure 4, each measurement appears to diverge from the Talys predictions using built-in α\alphaOMP, hinting at larger-than-predicted cross sections near threshold. Hauser-Feshbach calculations of α\alpha-induced reactions near threshold are known to be extremely sensitive to the tail of the adopted α\alphaOMP [34]. Thus, it could be that in this case a model tailored to address near-threshold energies (e.g. [47]) would be more appropriate for this lowest-energy region. As these lowest-energy data points are not the main focus of the present work, we do not perform such a comparison.

For additional comparisons, we must convert between the thick-target yield in units of n/αn/\alpha to units of MBq/μ\muAh, where the latter is more standard in the language of medical isotope production [48]. We denote the latter yield (often referred to as the physical yield [49]) as Y~\widetilde{Y} and note that, though expressed with units of activity, it does not account for radioactive decay of the produced nuclide during production or a cool-down period5. The conversion is

Y~=λqY,(3)\widetilde{Y}=\frac{\lambda}{q}Y, \tag*{(3)}

where λ\lambda is the decay constant of the produced nuclide and qq is the electric charge of the incident beam. We emphasize that the standard for helium beams with EαE_{\alpha} of several MeV or more is q=2eq=2e, as this is the charge-state realized in accelerators producing helium nuclei at these energies. We emphasize this because it appears to have been cause for some confusion in the literature. Namely, when Aslam et al. [8] re-report the results of Dmitriev [15], they quote yields that are smaller by ½ from that reported in the original work (when the original work is converted to an enriched 65^{65}Cu abundance). This is presumably under the assumption that Dmitriev [15] either adopted q=1eq=1e or meant particle microamps (μ\muA) instead of electrical microamps (eμe\muA), though Dmitriev [15] are explicit that eμe\muA are their meaning6 and they note that the relative charge of the bombarding particle is accounted for, i.e. q=2eq=2e. Meanwhile Kamal et al. [24] appear to misreport the result for their own Y~\widetilde{Y}. Those authors recommend the Y~\widetilde{Y} calculated based on σHF\sigma_{\mathrm{HF}} from Talys using α\alphaOMP model 3, stating it is 1558 MBq/μ\muAh for EαE_{\alpha} providing maximum yield (Eα>40E_{\alpha}>40 MeV). However, employing Eqn. 3 for this σHF\sigma_{\mathrm{HF}} yields a result of 680 MBq/μ\muAh for Eα=40E_{\alpha}=40 MeV. This is in-line with expectations, considering the IAEA yield at this energy is 796 MBq/μ\muAh [2] and the fact that the cross section calculation of Kamal et al. [24] slightly undershoots the Hermanne et al. [20] dataset that anchors the IAEA cross section fit (See Fig. 6 of [24]). We speculate that this ∼\sim×2 overestimate is due to an issue with qq in the YY–Y~\widetilde{Y} conversion.

After applying Eqn. 3 to the α\alphaOMP 1–6 Ycalc.Y_{\mathrm{calc.}} and adopting α\alphaOMP model 3 as the central estimate, we calculate the thick-target yield for 68^{68}Ga from Eα=14E_{\alpha}=14 MeV α\alpha-particles impinging on 100%-enriched copper (65^{65}Cu) is 161−24+5161^{+5}_{-24} MBq/μ\muAh (for He++^{++}). This agrees well with IAEA estimate 156 MBq/μ\muAh [2], is twice the result of Dmitriev [15], and is somewhat lower (12%) than the result of Aslam et al. [8]. As discussed above, it should agree with Kamal et al. [24], as they recommend essentially the same σHF\sigma_{\mathrm{HF}}.

To avoid the expense and complication of employing 100%-enriched 65Cu{}^{65}\mathrm{Cu}, it may be advantageous to perform 65Cu(α,n)68Ga{}^{65}\mathrm{Cu}(\alpha,n){}^{68}\mathrm{Ga} medical isotope production with natural copper targets. However, this would likely require irradiation at Eα=8E_{\alpha}=8 MeV in order to avoid radioisotope contamination from 63Cu(α,n)66Ga{}^{63}\mathrm{Cu}(\alpha,n){}^{66}\mathrm{Ga}, whose threshold is 7.923 MeV [12]. Using our Ymeas.Y_{\mathrm{meas.}} from Tab. 1 and assuming He++ on natural copper, we estimate a thick-target yield of 0.12±\pm0.02 MBq/μ\muAh. Meanwhile, the IAEA estimate [2] for these conditions is roughly 4×\times larger at 0.52 MBq/μ\muAh. The Dmitriev [15] and Aslam et al. [8] estimates are larger by ×\times2 and ×\times11 at 0.23 and 1.42 MBq/μ\muAh, respectively.

We briefly consider whether the yield for Eα=8E_{\alpha}=8 MeV on natural copper is large enough to be practically useful. Medical imaging with 68Ga{}^{68}\mathrm{Ga} requires an activity around 180 MBq [50]. The activity AA of the target immediately following irradiation for a time tirr.t_{\mathrm{irr.}} is

A(tirr.)=IαY(1−e−λtirr.)(4)A(t_{\mathrm{irr.}})=I_{\alpha}Y\left(1-e^{-\lambda t_{\mathrm{irr.}}}\right) \tag*{(4)}

and after a cooling time tcoolt_{\mathrm{cool}} following irradiation is

A(tcool)=A(tirr.)e−λtcool.(5)A(t_{\mathrm{cool}})=A(t_{\mathrm{irr.}})e^{-\lambda t_{\mathrm{cool}}}. \tag*{(5)}

Since λ=1.7×10−4 s−1\lambda=1.7\times10^{-4}\ \mathrm{s}^{-1} for 68Ga{}^{68}\mathrm{Ga} [51], A(tirr.)A(t_{\mathrm{irr.}}) reaches 75% saturation after tirr.≈2t_{\mathrm{irr.}}\approx2 h. Chemical separation of radiogallium from copper is possible with high extraction efficiency within another 2 h [52]. Assuming this time as tcoolt_{\mathrm{cool}}, the practically useful activity will be A(tcool)≈14A(tirr.)A(t_{\mathrm{cool}})\approx\frac{1}{4}A(t_{\mathrm{irr.}}). For our Ymeas.Y_{\mathrm{meas.}} at Eα=8E_{\alpha}=8 MeV, tirr.=2t_{\mathrm{irr.}}=2 h, and tcool=2t_{\mathrm{cool}}=2 h, a beam current of 5 mA would result in 210 MBq of 68Ga{}^{68}\mathrm{Ga}. Such a He++ beam current is within reach of medical isotope-production accelerators under development [e.g. 53]. Assuming the natural copper target thickness is 5 μ\mum, so that EαE_{\alpha} ranges from 8 MeV down to the 65Cu(α,n){}^{65}\mathrm{Cu}(\alpha,n) threshold, the target would sustain a power of 7.5 kW. While this is considerable, it is within the range of standard target-cooling approaches [54]. Therefore, radioimpurity-free production of 68Ga{}^{68}\mathrm{Ga} for use as a medical isotope via 65Cu(α,n){}^{65}\mathrm{Cu}(\alpha,n) at Eα=8E_{\alpha}=8 MeV using natural copper targets is technically feasible, if somewhat impractical.

Cross Section, Deep Underground Detector Backgrounds, and the Astrophysical Reaction Rate

Figure 5 shows the 65Cu(α,n){}^{65}\mathrm{Cu}(\alpha,n) cross section from all published direct measurements [11, 13, 16, 17, 18, 19, 20], compared to the evaluations of Tárkányi et al. [2] and Aslam et al. [8], the best-fit from Kudryavtsev et al. [3], and our Hauser-Feshbach calculations with α\alphaOMP models 1–8. The experimental data in this figure are all from stacked-foil activation measurements, likely with significant uncertainties and inaccuracies at the lowest EαE_{\alpha}, as discussed. The evaluations of Tárkányi et al. [2] and Aslam et al. [8] rely on these data and thus at low EαE_{\alpha} also significantly exceed the Hauser-Feshbach estimates that agree with our and previous thick-target yield data from single-foil irradiations (See Sec. 3). Kudryavtsev et al. [3], meanwhile, recommend a cross section obtained from a Hauser-Feshbach calculation that best reproduces the cross section data derived from the Stelson and McGowan [14] thick-target yield. As our Hauser-Feshbach calculations also agree with this dataset, they are in agreement with the recommended cross section from Kudryavtsev et al. [3]. The Kudryavtsev et al. [3] calculation is the basis for the 65Cu(α,n){}^{65}\mathrm{Cu}(\alpha,n) contribution to the background for deep underground dark matter and neutrino detectors. An alternative 65Cu(α,n){}^{65}\mathrm{Cu}(\alpha,n) background estimate comes from Neutron Calculator Based on Talys (NeuCBOT) [5], which also uses Talys calculations to reproduce the measurements of Stelson and McGowan [14]. We therefore conclude that this background contribution is accurately accounted for.

Figure 5. 65^{65}Cu(α,n\alpha,n) cross section calculated with Talys α\alphaOMP models 1–8 (gray lines) compared to recommendations from Kudryavtsev et al. [3] (green line), Aslam et al. [8] (black dotted band), Tárkányi et al. [2] (red hashed band), and all published direct measurement data [11, 13, 16, 17, 18, 19, 20]. The orange and gray bands near the bottom of the figure show the energy regions relevant for astrophysics and deep underground detector backgrounds, respectively.

The nuclear reaction cross section is a key ingredient for the astrophysical reaction rate,

NA⟨σv⟩∝∫σ(E)Ee−E/kBT dE,(6)N_{\mathrm{A}}\langle\sigma v\rangle\propto\int\sigma(E)E e^{-E/k_{\mathrm{B}}T}\,dE, \tag*{(6)}

where kBk_{\mathrm{B}} is the Boltzmann constant, TT is the environment temperature, and EE is the reaction energy in the center-of-mass frame. The energy range in which σ(E)\sigma(E) must be known is where the integrand of Eqn. 6 is largest. The energy bound containing 90% of the integral is known as the astrophysical window. While the 65Cu(α,n){}^{65}\mathrm{Cu}(\alpha,n) reaction rate has been of astrophysical interest for explosive nucleosynthesis in general [4], modern interest in (α,n)(\alpha,n) reactions for copper isotopes is ν\nu-driven wind nucleosynthesis of elements from strontium to silver [55]. Though 68Cu(α,n){}^{68}\mathrm{Cu}(\alpha,n) is of particular interest for this site, it is expected that an α\alphaOMP that accurately captures the α+65Cu\alpha+{}^{65}\mathrm{Cu} interaction should adequately capture the α+67Cu\alpha+{}^{67}\mathrm{Cu} interaction as well.

In this spirit, we compare 65Cu(α,n){}^{65}\mathrm{Cu}(\alpha,n) astrophysical reaction rates calculated using α\alphaOMP models 1–8 in Talys to other predictions [56, 57, 58] in Figure 6. While the REACLIB reaction rate library [58] has often been employed in astrophysics model calculations, it evidently significantly underestimates the 65Cu(α,n){}^{65}\mathrm{Cu}(\alpha,n) reaction rate relative to our Hauser-Feshbach calculations. Recently, the Atomki-V2 α\alphaOMP was developed to improve the description of α\alpha-induced astrophysical reaction rates [47]. Rates have been calculated with this α\alphaOMP by Mohr et al. [56] and Rauscher [57], using independent Hauser-Feshbach codes and likely differing in input assumptions; nonetheless, these rates are within 11% of each other over the 3–5 GK temperature range of interest for ν\nu-driven wind nucleosynthesis. Each are also within a factor of two of the α\alphaOMP model 1–6 rates recommended here. This is consistent with expectation of Psaltis et al. [55] that a factor of three variation in the Atomki-V2-derived (α,n)(\alpha,n) rates is adequate to capture outstanding uncertainties. Based on the thick-target yield comparisons discussed in Sec. 3, we 色综合 recommend the 65^{65}Cu(α,n\alpha,n) astrophysical reaction rate calculated using Talys with α\alphaOMP model 3, with an uncertainty of 25% to account for the similar performance of α\alphaOMP models 1–6. This rate is within 25% of the Atomki-V2 rates within 3–5 GK, therefore those rates would be equally suitable in ν\nu-driven wind nucleosynthesis calculations.

Figure 6. Ratio of astrophysical reaction rates calculated with α\alphaOMP models 1–8, the Atomki-V2 α\alphaOMP rates calculated by Mohr et al. [56] and Rauscher [57], and the recommended rate in the REACLIB database [58], to the rate calculated with α\alphaOMP model 3, over the temperature range of interest for ν\nu-driven wind nucleosynthesis.

Conclusions

In conclusion, we performed thick-target yield measurements of 65^{65}Cu(α,n\alpha,n) 68^{68}Ga near threshold, along with Hauser-Feshbach calculations in order to evaluate the impact of our measurements for nuclear medicine, deep-underground measurements of neutrinos and dark matter, and nuclear astrophysics. We determined that the thick-target yield for 68^{68}Ga from Eα=14E_{\alpha}=14 MeV α\alpha-particles impinging on 100%-enriched copper (65^{65}Cu) is 161−24+5161^{+5}_{-24} MBq/μ\muAh (for He++), which is in agreement with the current IAEA estimate, though our yield at Eα=8E_{\alpha}=8 MeV is four times lower than the IAEA estimate. We found that the Eα=8E_{\alpha}=8 MeV yield is sufficient to enable radioimpurity-free production of 68^{68}Ga for use as a medical isotope via 65^{65}Cu(α,n\alpha,n) using natural copper targets, at least in principle.

Comparisons to our and previous single-foil irradiation data for 65^{65}Cu(α,n\alpha,n) suggest that the 65^{65}Cu(α,n\alpha,n) cross section, and therefore astrophysical reaction rate, is accurately described by Hauser-Feshbach calculations performed using Talys α\alphaOMP models 1–6. These cross sections and rates are in agreement with those currently adopted for deep underground detector backgrounds and for astrophysical nucleosynthesis calculations, respectively. Namely, the cross section recommended by Kudryavtsev et al. [3] and the rates of Mohr et al. [56] and Rauscher [57]. Our results suggest a 65^{65}Cu(α,n\alpha,n) cross section and reaction rate uncertainty of around 25%, which is likely sufficient for the purposes of detector backgrounds and nucleosynthesis calculations.

Acknowledgements

The views expressed are those of the authors and do not reflect the official guidance or position of the United States Government, the United States Department of War, or the United States Air Force. This work was supported in part by the U.S. Department of Energy Office of Science under Grants No. 89243126SSC0000179, DE-FG02-88ER40387, and DE-SC0019042 and the U.S. National Nuclear Security Administration through Grants No. DE-NA0003883 and DE-NA0003909. The helium ion source was provided by Grant No. PHY-1827893 from the U.S. National Science Foundation. We also benefited from support by U.S. Department of Energy Office of Science under Grant No. DE-SC0023128 (CeNAM).

References

  1. [1]S. M. Qaim, Nuclear data for production and medical application of radionuclides: Present status and future needs, Nuclear Medicine and Biology 44 (2017) 31. doi:10.1016/j.nucmedbio.2016.08.016.
  2. [2]F. T. Tárkányi, A. V. Ignatyuk, A. Hermanne, R. Capote, B. V. Carlson, J. W. Engle, M. A. Kellett, T. Kibédi, G. N. Kim, F. G. Kondev, M. Hussain, O. Lebeda, A. Luca, Y. Nagai, H. Naik, A. L. Nichols, F. M. Nortier, S. V. Suranyanarayana, S. Takács, M. V. Verpelli, Recommended nuclear data for medical radioisotope production: diagnostic positron emitters, Journal of Radioanalytical and Nuclear Chemistry 319 (2019) 533. doi:10.1007/s10967-018-6380-5.DOI
  3. [3]V. A. Kudryavtsev, L. Th. V. Tomasello, V. Tomasello, Neutron- and muon-induced background in underground physics experiments, European Physical Journal A 36 (2008) 171–180. doi:10.1140/epja/i2007-10539-6.
  4. [4]N. A. Roughton, T. P. Intrator, R. J. Peterson, C. S. Zaidins, C. J. Hansen, Thick-Target Measurements and Astrophysical Thermonuclear Reaction Rates: Alpha-Induced Reactions, Atomic Data and Nuclear Data Tables 28 (1983) 341. doi:10.1016/0092-640X(83)90021-9.DOI
  5. [5]S. Westerdale, P. D. Meyers, Radiogenic neutron yield calculations for low-background experiments, Nuclear Instruments and Methods in Physics Research A 875 (2017) 57–64. doi:10.1016/j.nima.2017.09.007.DOI
  6. [6]R. P. Baum, H. R. Kulkarni, Theranostics: From molecular imaging using Ga-68 labeled tracers and PET/CT to personalized radionuclide therapy - The Bad Berka experience, Theranostics 2 (2012) 437. doi:10.7150/thno.3645.DOI
  7. [7]S. R. Banerjee, M. G. Pomper, Clinical applications of Gallium-68, Applied Radiation and Isotopes 76 (2013) 2. doi:10.1016/j.apradiso.2013.01.039.DOI
  8. [8]M. T. Aslam, W. Ali, M. Hussain, Nuclear model analysis of the 65Cu(α,n)68Ga reaction for the production of 68Ga up to 40 MeV, Applied Radiation and Isotopes 170 (2021) 109590. doi:10.1016/j.apradiso.2021.109590.DOI
  9. [9]K. Brandenburg, G. Hamad, Z. Meisel, C. R. Brune, D. E. Carter, R. J. deBoer, J. Derkin, C. Feathers, D. C. Ingram, Y. Jones-Alberty, B. Kenady, T. N. Massey, M. Saxena, D. Soltesz, S. K. Subedi, A. Voinov, J. Warren, M. Wiescher, Measurements of the 13C(α,n)16O cross section up to Eα=8 MeV, Physical Review C Letters 108 (2023) L061601. doi:10.1103/PhysRevC.108.L061601.DOI
  10. [10]T. Rauscher, Relevant energy ranges for astrophysical reaction rates, Physical Review C 81 (2010) 045807. doi:10.1103/PhysRevC.81.045807.DOI
  11. [11]F. Szelecsényi, Z. Kovács, K. Nagatsu, K. Fukumura, K. Suzuki, K. Mukai, Investigation of direct production of 68Ga with low energy multiparticle accelerator, Radiochimica Acta 100 (2012) 5. doi:10.1524/ract.2011.1896.DOI
  12. [12]M. Wang, W. J. Huang, F. G. Kondev, G. Audi, S. Naimi, The AME 2020 atomic mass evaluation (II). Tables, graphs and references, Chinese Physics C 45 (2021) 030003. doi:10.1088/1674-1137/abdada.
  13. [13]E. A. Bryant, D. R. Cochran, J. D. Knight, Excitation Functions of Reactions of 7- to 24-MeV He3 Ions with Cu63 and Cu65, Physical Review 130 (1963) 1512–1522. doi:10.1103/PhysRev.130.1512.DOI
  14. [14]P. H. Stelson, F. K. McGowan, Cross Section for (α,n) Reactions for Medium-Weight Nuclei, Physical Review 133 (1964) 911–919. doi:10.1103/PhysRev.133.B911.
  15. [15]P. P. Dmitriev, IAEA translation of Radionuclide Yield in Reactions with Protons, Deuterons, Alpha Particles and Helium-3 (Handbook), INDC(CCP)-263/G+CN+SZ, International Atomic Energy Agency, Vienna, Austria, 1986. URL: https://nds.iaea.org/record/9dpghr8m04.
  16. [16]H. D. Bhardwaj, A. K. Gautam, R. Prasad, Measurement and analysis of excitation functions for alpha-induced reactions in copper, Pramana 31 (1988) 109–123. doi:10.1007/BF02846965.DOI
  17. [17]V. N. Levkovskij, Middle Mass Nuclides (A = 40-100) Activation Cross Sections By Medium Energy (E= 10-50 MeV) Protons and Alpha Particles (Experiment and Systematics), Inter-vesi, Moscow, Russia, 1991.
  18. [18]O. Bonesso, M. J. Ozafran, H. O. Mosca, M. E. Vazquez, O. A. Capurro, S. J. Nassiff, Study of pre-equilibrium effects on α-induced reactions on copper, Journal of Radioanalytical and Nuclear Chemistry 152 (1991) 189. doi:10.1007/BF02042152.DOI
  19. [19]N. L. Singh, B. J. Patel, D. R. S. Somayajulu, S. N. Chintalapudi, Analysis of the excitation functions of (α, xnyp) reactions on natural copper, Pramana 42 (1994) 349–363. doi:10.1007/BF02847761.DOI
  20. [20]A. Hermanne, R. Adam Rebeles, F. Tárkányi, S. Takács, Alpha particle induced reactions on natCu up to 39 MeV: Experimental cross-sections, comparison with theoretical calculations and thick target yields for medically relevant 52gFe production, Nuclear Instruments and Methods in Physics Research B 356 (2015) 28–41. doi:10.1016/
  21. [21]H. Paul, A. Schinner, Judging the reliability of stopping power tables and programs for protons and alpha particles using statistical methods, Nuclear Instruments and Methods in Physics Research B 227 (2005) 461–470. doi:10.1016/j.nimb.2004.10.007.DOI
  22. [22]C. C. Montanari, P. Dimitriou, The IAEA stopping power database, following the trends in stopping power of ions in matter, Nuclear Instruments and Methods in Physics Research B 408 (2017) 50–55. doi:10.1016/j.nimb.2017.03.138.DOI
  23. [23]W. Hauser, H. Feshbach, The Inelastic Scattering of Neutrons, Physical Review 87 (1952) 366–373. doi:10.1103/PhysRev.87.366.DOI
  24. [24]N. Kamal, S. Nizam, A. Abdul Aziz, The effects of nuclear level density model and alpha optical model potential to the excitation functions of novel therapeutic radionuclides, Applied Radiation and Isotopes 203 (2024) 111085. doi:10.1016/j.apradiso.2023.111085.
  25. [25]Z. Meisel, C. Brune, S. Grimes, D. Ingram, T. Massey, A. Voinov, The Edwards Accelerator Laboratory at Ohio University, Physics Procedia 90 (2017) 448–454. doi:10.1016/j.phpro.2017.09.050.DOI
  26. [26]K. Brandenburg, G. Hamad, Z. Meisel, C. R. Brune, D. E. Carter, T. Danley, J. Derkin, Y. Jones-Alberty, B. Kenady, T. N. Massey, S. Paneru, M. Saxena, D. Soltesz, S. K. Subedi, J. Warren, The 3He BF3 Giant Barrel (HeBGB) neutron detector, Journal of Instrumentation 17 (2022) P05004. doi:10.1088/1748-0221/17/05/P05004.DOI
  27. [27]K. Brandenburg, G. Hamad, Z. Meisel, C. R. Brune, D. E. Carter, J. Derkin, D. C. Ingram, Y. Jones-Alberty, B. Kenady, T. N. Massey, M. Saxena, D. Soltesz, S. K. Subedi, J. Warren, Measurements of the 27Al(α,n) Thick Target Yield near Threshold, Nuclear Science and Engineering 197 (2023) 510–516. doi:10.1080/00295639.2022.2114833.
  28. [28]A. C. Douglas, N. MacDonald, Compound nucleus processes in medium mass nuclei, Nuclear Physics 13 (1959) 382–396. doi:10.1016/0029-5582(59)90116-6.DOI
  29. [29]S. M. Grimes, J. D. Anderson, J. W. McClure, B. A. Pohl, C. Wong, Level density and spin cutoff parameters from continuum (p,n) and (α,n) spectra, Physical Review C 10 (1974) 2373–2386. doi:10.1103/PhysRevC.10.2373.DOI
  30. [30]G. Blondiaux, M. Valladon, L. Quaglia, G. Robaye, G. Weber, J. L. Debrun, Study of the growth of carbon on targets during ion bombardment, Nuclear Instruments and Methods in Physics Research A 227 (1984) 19–23. doi:10.1016/0168-9002(84)90095-0.DOI
  31. [31]M. Berglund, M. E. Wieser, Isotopic compositions of the elements 2009 (IUPAC Technical Report), Pure and Applied Chemistry 83 (2011) 397. doi:10.1351/PAC-REP-10-06-02.DOI
  32. [32]A. Koning, S. Hilaire, S. Goriely, TALYS: modeling of nuclear reactions, European Physical Journal A 59 (2023) 131. doi:10.1140/epja/s10050-023-01034-3.DOI
  33. [33]J. F. Ziegler, M. D. Ziegler, J. P. Biersack, SRIM - The stopping and range of ions in matter (2010), Nuclear Instruments and Methods in Physics Research B 268 (2010) 1818–1823. doi:10.1016/j.nimb.2010.02.091.
  34. [34]P. Mohr, Cross sections of α-induced reactions for targets with masses A ≈ 20-50 at low energies, European Physical Journal A 51 (2015) 56. doi:10.1140/epja/i2015-15056-5.DOI
  35. [35]T. Rauscher, Sensitivity of Astrophysical Reaction Rates to Nuclear Uncertainties, Astrophysical Journal Supplement Series 201 (2012) 26. doi:10.1088/0067-0049/201/2/26.DOI
  36. [36]L. McFadden, G. R. Satchler, Optical-model analysis of the scattering of 24.7 MeV alpha particles, Nuclear Physics 84 (1966) 177–200. doi:10.1016/0029-5582(66)90441-X.DOI
  37. [37]P. Demetriou, C. Grama, S. Goriely, Improved global α-optical model potentials at low energies, Nuclear Physics A 707 (2002) 253–276. doi:10.1016/S0375-9474(02)00576-X.
  38. [38]V. Avrigeanu, M. Avrigeanu, C. Măinăilescu, Further explorations of the α-particle optical model potential at low energies for the mass range A≈45-209, Physical Review C 90 (2014) 044612. doi:10.1103/PhysRevC.90.044612.DOI
  39. [39]M. Nolte, H. Machner, J. Bojowald, Global optical potential for α particles with energies above 80 MeV, Physical Review C 36 (1987) 1312–1316. doi:10.1103/PhysRevC.36.1312.
  40. [40]V. Avrigeanu, P. E. Hodgson, M. Avrigeanu, Global optical potentials for emitted alpha particles, Physical Review C 49 (1994) 2136–2141. doi:10.1103/PhysRevC.49.2136.
  41. [41]H. H. Andersen, J. F. Bak, H. Knudsen, B. R. Nielsen, Stopping power of Al, Cu, Ag, and Au for MeV hydrogen, helium, and lithium ions. Z³₁ and Z⁴₇ proportional deviations from the Bethe formula, Physical Review A 16 (1977) 1929–1940. doi:10.1103/PhysRevA.16.1929.
  42. [42]R. Ishiwari, N. Shiomi, T. Katayama-Kinoshita, F. Sawada-Yasue, Search for Possible Geometrical Effect on Stopping Power Measurement, Journal of the Physical Society of Japan 39 (1975) 557–565. doi:10.1143/JPSJ.39.557.DOI
  43. [43]R. Ishiwari, N. Shiomi, T. Kinoshita, F. Yasue, Stopping powers of Al, Ni, Cu, Ag, and Ta for 8.78 MeV alpha particles, Bulletin of the Institute for Chemical Research, Kyoto University 55 (1977) 68. URL: http://hdl.handle.net/2433/75168.
  44. [44]M. J. Berger, J. S. Coursey, M. A. Zucker, J. Chang, Stopping-Power & Range Tables for Electrons, Protons, and Helium Ions, Technical Report, National Institute of Standards and Technologies, 2017. doi:10.18434/T4NC7P.
  45. [45]F. Bivort Haiek, A. M. P. Mendez, C. C. Montanari, D. M. Mitnik, ESPN: A novel electronic stopping power neural-network code built on the IAEA stopping power database. I. Atomic targets, Journal of Applied Physics 132 (2022) 245103. doi:10.1063/5.0130875.
  46. [46]W. R. Leo, Techniques for Nuclear and Particle Physics Experiments, Springer-Verlag Berlin Heidelberg, New York, USA, 1994.
  47. [47]P. Mohr, Z. Fülöp, G. Gyürky, G. G. Kiss, T. Szűcs, Successful Prediction of Total α-Induced Reaction Cross Sections at Astrophysically Relevant Sub-Coulomb Energies Using a Novel Approach, Physical Review Letters 124 (2020) 252701. doi:10.1103/PhysRevLett.124.252701.DOI
  48. [48]International Atomic Energy Agency, Charged Particle Cross-Section Database for Medical Radioisotope Production: Diagnostic Radioisotopes and Monitor Reactions, number 1211 in IAEA-TECDOC, International Atomic Energy Agency, Vienna, 2001. URL: http://www-iaea.org/publications/6050/charged-particle-cross-section-database-for-medical-radioisotope-production-diagnostic-radioisotopes-and-monitor-reactions.
  49. [49]N. Otuka, S. Takács, Definitions of radioisotope thick target yields, Radiochimica Acta 103 (2015) 1–6. URL: https://doi.org/10.1515/ract-2013-2234. doi:doi:10.1515/ract-2013-2234.
  50. [50]R. C. Walker, G. T. Smith, E. Liu, L. B. Moore, J. Clanton, M. Stabin, Measured human dosimetry of 68Ga-DOTATATE, Journal of Nuclear Medicine 54 (2013) 855–860. URL: https://jnm.snmjournals.org/content/54/5/855. doi:10.2967/jnumed.112.114165.DOI
  51. [51]E. A. McCutchan, Nuclear Data Sheets for A = 68, Nuclear Data Sheets 113 (2012) 1735–1870. doi:10.1016/j.nds.2012.06.002.DOI
  52. [52]K. F. Hassan, Rapid preparation of radiogallium from Zn and Cu targets using anion exchange technique, Journal of Radioanalytical and Nuclear Chemistry 289 (2011) 801. doi:10.1007/s10967-011-1145-4.DOI
  53. [54]International Atomic Energy Agency, Cyclotron Produced Radionuclides: Principles and Practice, number 465 in Technical Reports Series, International Atomic Energy Agency, Vienna, 2008. URL: http://www.iaea.org/publications/7849/cyclotron-produced-radionuclides-principles-and-practice.
  54. [55]A. Psaltis, A. Arcones, F. Montes, P. Mohr, C. J. Hansen, M. Jacobi, H. Schatz, Constraining Nucleosynthesis in Neutrino-driven Winds: Observations, Simulations, and Nuclear Physics, Astrophysical Journal 935 (2022) 27. doi:10.3847/1538-4357/ac7da7.DOI
  55. [56]P. Mohr, Z. Fülöp, G. Gyürky, G. G. Kiss, T. Szűcs, A. Arcones, M. Jacobi, A. Psaltis, Astrophysical reaction rates of α-induced reaction rates for nuclei with 26≤Z≤83 from the new Atomki-V2 α-nucleus potential, Atomic Data and Nuclear Data Tables 142 (2021) 101453. doi:10.1016/j.adt.2021.101453.DOI
  56. [57]T. Rauscher, Astrophysical reaction rates for charged-particle induced reactions on proton-rich nuclei, European Physical Journal A 62 (2026) 35. doi:10.1140/epja/s10050-026-01809-4.DOI
  57. [58]R. H. Cyburt, A. M. Amthor, R. Ferguson, Z. Meisel, K. Smith, S. Warren, A. Heger, R. D. Hoffman, T. Rauscher, A. Sakhukar, H. Schatz, F. K. Thielemann, M. Wiescher, The JINA REACLIB Database: Its Recent Updates and Impact on Type-I X-ray Bursts, Astrophysical Journal Supplement Series 189 (2010) 240–252. doi:10.1088/0067-0049/189/1/240.

Paper details

vlnc:W_mvs8kwph
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 10

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…