Fairness Evaluation for Diffusion and Flow Models Should Account for the Generation Path: Implications for Clinical Imaging

Abstract

Medical image generation models are often evaluated using images produced by a single sampling procedure. However, diffusion and flow models can use different numbers of sampling steps, sampling schedules, or numerical solvers without changing their trained parameters. These changes may affect the generated images and the clinical measurements derived from them. We argue that fairness results obtained under one sampling procedure should not be assumed to hold under another, particularly when changes in sampling affect clinical task errors differently across patient groups. Building on previous work on medical image quality, accelerated sampling, generation dynamics, and generative model fairness, we examine why the sampling procedure should be considered part of the evaluated system. We define subgroup differences in clinical task error across sampling procedures and provide a mathematical example showing that two groups can have identical outputs under the exact dynamics and a reference sampler but different errors under an alternative sampler. We also extend this result to stochastic generation under shared noise. An exploratory experiment with an age-conditioned image generation model illustrates how changing the number and timing of sampling steps can alter image-derived measurements, although these differences do not establish clinical unfairness. We therefore argue that fairness evaluation should assess the sampling procedure used in practice and examine intermediate generation states when they help explain differences in clinically relevant errors across patient groups. Analysis code is available here https://github.com/rdharini2001/generation-path-fairness

Introduction

Quantitative measurements derived from medical images are used to assess vascular disease, cancer, and other conditions, including in digital pathology [41, 7]. These measurements depend on accurate anatomical structures and tissue patterns, including vessels, lesion boundaries, and cell arrangements relevant to cancer studies [50]. Small changes in these structures can affect clinical measurements even when the overall image appears realistic. Previous studies have shown that medical image generation and reconstruction methods can introduce false anatomical features or fail to preserve important structures. Conventional image similarity metrics may not adequately capture these errors [13, 4, 8, 17, 16]. This concern is particularly relevant for vascular structures, where small changes in vessel continuity or geometry may affect quantitative measurements [55, 24, 60].

Generative models are being investigated for medical image synthesis, reconstruction, and quantitative analysis, including histopathology and MRI [5, 40]. In retinal imaging, for example, these methods have been explored for generating vascular images and studying microvascular measurements associated with disease [14, 10, 48, 45, 74]. Such applications require careful evaluation of whether generated images preserve the anatomical information needed for the intended clinical task. Related MRI and radiographic studies also rely on image-derived findings for clinical decisions and risk assessment [61, 43, 71, 72, 73]. Visual similarity alone is insufficient when small structural differences can change measurements or downstream predictions.

For diffusion and flow-based models, the reliability of these measurements may also depend on the sampling procedure. These models generate images through successive numerical updates, and the number of sampling steps, their placement along the generation process, and the numerical solver can be changed without retraining the model [23, 58, 34, 35]. Such changes are often made to reduce computational cost or inference time. However, modifying the sampling procedure can change the generated images and their derived measurements, even when the model parameters remain fixed. A model evaluated using one sampling procedure may therefore behave differently when deployed with another, including in ways that affect clinical task errors across patient groups.

We argue that fairness evaluation for diffusion and flow-based models should account for the sampling procedure used to generate the images and the clinical task for which those images are intended. Fairness results obtained under one sampling procedure cannot be assumed to hold when that procedure changes. Evaluating intermediate generation states may also help explain when and how changes in sampling affect clinically relevant information. However, differences between generation trajectories do not necessarily indicate unfairness. Patient anatomy, disease severity, and acquisition conditions may legitimately influence the generation process. The relevant concern is whether changes in sampling lead to unequal changes in clinical task error across patient groups.

To support this position, we review previous work on medical image quality, numerical sampling, intermediate generation features, and fairness evaluation. We then define subgroup differences in clinical task error across sampling procedures and provide a mathematical example showing why fairness results under one sampler do not necessarily hold under another. Finally, we use an exploratory age-conditioned image generation example to illustrate how sampling choices can alter image-derived measurements. Although these observations do not establish clinical unfairness, they demonstrate why changes in the sampling procedure warrant further evaluation using independent clinical reference measurements.

What Previous Work Tells Us

Clinical image quality depends on the intended task. Medical image generation and reconstruction methods can produce realistic images while introducing false anatomical features or removing clinically important structures [13, 4, 8]. Studies of GAN-generated medical images and image-quality metrics have shown that visual similarity and distributional measures do not always reflect clinically relevant information [27, 56, 17, 16, 29, 59]. For vascular imaging, measures of vessel continuity and topology provide more direct assessments of structural accuracy [22, 55, 60]. Work on clinical feedback for synthetic images and image quality in retinal prediction also shows the value of task-specific assessment [62, 47]. Outside medicine, AVID provides an example of task-specific evaluation by testing how target size, sensor misalignment, and image corruption affect feature-based comparisons in aerial imagery [44]. These findings support evaluating generated images according to their intended clinical use. However, evaluations of final images under one sampling procedure do not establish whether the same results hold when that procedure changes.

Sampling choices can affect generated images. Diffusion and flow-based models generate images through successive transformations, including denoising, continuous flows, and stochastic processes [23, 58, 34, 35, 3, 28]. Methods such as DDIM, DPM-Solver, and EDM, together with work on timestep schedules, parallel sampling, temporal attention, and distillation, have shown how generation can be made more efficient [57, 37, 26, 51, 54, 36, 70]. These changes can affect generated images without modifying the trained model. However, improvements in sampling efficiency or image quality do not establish whether clinical measurements remain equally accurate across patient groups when the sampling procedure changes.

Intermediate generation states contain useful information. Previous studies have shown that image features and learned representations change throughout diffusion-based generation [12, 39, 9]. Li and Chen examined critical windows during which features emerge, including their relevance to fairness analysis [31]. Related work has investigated when features become detectable and how intermediate representations can be examined [32, 2, 21]. These studies provide a basis for understanding generation dynamics. However, identifying differences in intermediate features does not establish whether they affect clinical measurements. Their relevance to fairness depends on whether they help explain differences in clinical task error across patient groups.

Fairness evaluation requires clinically meaningful comparisons. Previous research on generative model fairness has examined demographic representation, differences in image attributes, and methods for reducing bias [38, 20, 53, 42, 33]. Fairness measurement also requires defining which differences between groups are meaningful [63]. Work on generative clinical language models provides another example: tests of deductive reasoning evaluate whether diagnostic constraints are followed rather than relying on common diagnostic patterns [46]. Data collection and synthetic-data sharing introduce related questions about population coverage, privacy, and fairness [1, 18]. In medical imaging, disease severity, anatomy, acquisition conditions, and distribution shifts can influence subgroup performance [15, 11, 52, 25, 68, 64]. Differences in generation trajectories therefore do not necessarily indicate unfairness. A meaningful evaluation should examine clinically relevant errors while accounting for appropriate patient and acquisition factors. Observational subgroup comparisons should also be distinguished from causal claims [30].

Previous work establishes the importance of clinical image quality, sampling choices, and intermediate generation states. However, it remains unclear whether fairness results obtained under one sampling procedure remain valid when that procedure changes. We argue that this question requires comparing clinical task errors across sampling procedures and patient groups, using intermediate states when they help explain the observed differences.

Our position: evaluate the sampling procedure used in practice

Let Gθ,s(U,Z)G_{\theta,s}(U, Z) be the output of a trained generator given patient input UU, random input ZZ, and sampling procedure ss. The sampling procedure includes the solver, number and timing of steps, and precision. Any downstream use of intermediate states is a separate component of the evaluated pipeline. Let TT represent the clinical measurement or decision made from the output, and let Y∗Y^{*} be an independent reference. For subgroup A=gA = g and relevant clinical or acquisition variables Q=qQ = q, we define the standardized task error as

Rg(s)=∫E[ℓ(T(Gθ,s(U,Z)),Y∗)∣A=g,Q=q] w(q) dq,(1)R_g(s) = \int\mathbb{E}[\ell(T(G_{\theta,s}(U, Z)), Y^{*}) \mid A = g, Q = q]\,w(q)\,\mathrm{d}q, \tag*{(1)}

where ℓ\ell is a prespecified loss and ww is a common distribution over values of QQ represented in both groups. The choice of adjustment variables matters. Adjusting for a factor that carries a disparity could hide it. The difference in task error between groups under sampler ss is D(s)=Rb(s)−Ra(s)D(s) = R_b(s) - R_a(s). We compare this with the difference under a reference sampler s0s_0:

ΔD(s,s0)={Rb(s)−Rb(s0)}−{Ra(s)−Ra(s0)}.(2)\Delta D(s, s_0) = \{R_b(s) - R_b(s_0)\} - \{R_a(s) - R_a(s_0)\}. \tag*{(2)}

Here, D(s)D(s) measures the subgroup gap for a given sampler, while ΔD\Delta D measures how that gap changes when the sampler changes. Neither quantity alone establishes unfairness. Interpretation requires the error in each group, uncertainty estimates, a clinically meaningful threshold, and an explanation of relevant patient differences. For plausible sampling procedures P\mathcal{P}, we check whether subgroup errors and their differences remain acceptable across P\mathcal{P}.

Changing the sampler while holding the input and random noise fixed allows a controlled comparison of computational choices. Comparing patients by age or another characteristic is different: it is generally observational. Shared random seeds do not make such a comparison a causal test of fairness.

Figure 1 shows what stays fixed and what changes when samplers are compared. The model weights and starting noise can remain the same, while the resulting image and clinical measurements may differ. Evaluation should test the task error for each patient group under each relevant sampler using independent references. Intermediate states can help explain where errors arise, but differences between those states are not, by themselves, evidence of unfairness.

Audit of a conditional generator under sampler $s$: noise $z$ passes through flow $v_\theta(x,t;a)$, solver $(s,\tau_s)$, sample $F_s(z,a)$, and biomarker $\phi(x)$; conditions $a$ and $b$ and step grid $\tau_s$ are shown. Stage 1 is the fixed conditional model and Stage 2 is deployment choice $s$ and measurement.

Figure 1. Sampling is part of the evaluated system. With the model and random input held fixed, changing the solver or sampling steps may change the generated output. Any subgroup comparison therefore applies to the sampler tested. The diagram shows image-derived group contrasts, not the clinical task-error gap D(s)D(s) defined above or validation against clinical reference data.

Why endpoint fairness may not transfer between samplers

Fairness results obtained with one sampling procedure do not necessarily remain valid when that procedure changes. To understand why, consider two groups whose generation trajectories differ but lead to identical outputs under the exact continuous dynamics. A reference numerical sampler may also produce identical endpoints for both groups. However, changing the number of sampling steps can introduce numerical errors that differ between the groups, even though the trained model and its underlying dynamics remain unchanged.

Proposition 1 (Fairness under one sampler need not hold under another). For any reference step count N≥2N \ge2, any different positive integer mm, and any M>0M > 0, there exist two smooth group-conditional ODEs whose exact solutions have identical endpoints and whose outputs also agree under NN-step forward Euler sampling. When the same ODEs are evaluated using mm-step forward Euler, the absolute difference between their numerical endpoints is at least MM. The vector fields remain unchanged across the two sampling procedures. An analogous result holds for an additive-noise SDE when the groups are coupled using the same Brownian path.

The construction uses a quadratic time-dependent drift chosen so that its integral over the full generation interval is zero. Although the exact endpoints agree, forward Euler introduces a difference between the numerical solutions:

x^b(k)(1)−x^a(k)(1)=KN−kk2(3N−1),(3)\hat{x}_b^{(k)}(1)-\hat{x}_a^{(k)}(1)=K\frac{N-k}{k^2(3N-1)}, \tag*{(3)}

where K>0K > 0 determines the size of the difference. The numerical endpoints are identical when k=Nk=N, but they differ for any alternative step count k=mk=m. If both groups have the same target and task error is measured using absolute endpoint loss, this numerical difference also produces unequal task errors. Appendix § 10 provides the full derivation, an analytical illustration, and the corresponding stochastic argument. The result establishes that agreement under one sampler does not guarantee agreement under another. It does not imply that such differences are common in medical image generation or that they necessarily lead to clinically meaningful harm.

A separate issue arises when another part of the system uses intermediate generation states. Two trajectories can begin and end at the same values while passing through different intermediate states. If a downstream model uses one of these states for editing, distillation, or another operation, the differences may influence its output even when the original generator produces identical final images (Appendix § 11). In contrast, when a fixed sampling procedure has been clinically validated and only its final output is used, there is no reason to require the intermediate trajectories of different patient groups to be identical.

Measurements of generation paths must therefore be interpreted in the context of the sampling procedure and intended clinical task. Quantities such as trajectory energy and distance traveled can change with the time parameterization or numerical step grid, while stochastic comparisons also depend on how random noise is coupled across groups. We do not consider differences in path length or intermediate representations sufficient evidence of unfairness. Appendix § 12 provides a bound on changes in task error and discusses its limitations for measurements such as vessel connectivity, where small image changes can produce substantial differences in the measured outcome.

A clinical example for testing the position

A useful clinical evaluation would examine a generative model whose outputs can be compared with independent reference measurements. Retinal-vessel segmentation or reconstruction provides one possible setting, particularly when the generated output is used to estimate vessel density, continuity, or other measures of vascular structure. A small vessel branch may be lost or incorrectly reconstructed without producing a large change in overall image similarity, yet the resulting error could affect a clinically relevant measurement. Previous work on retinal imaging and topology-aware segmentation provides methods for evaluating the preservation of these structures [10, 55, 22, 67]. Research on retinal biomarkers and cardiovascular risk prediction further illustrates the importance of relating image-derived measurements to a clearly defined clinical outcome [49].

Such a study could evaluate the same patient images using a fixed model checkpoint under a reference sampler and several faster alternatives. The resulting segmentations or reconstructed images would be compared with expert annotations or independent imaging references, allowing task errors to be measured for each patient. The analysis would then examine whether changing the sampling procedure produces larger increases in error for some patient groups than others, while accounting for clinically relevant differences in anatomy, disease severity, and acquisition conditions. This design would distinguish changes caused by numerical sampling from differences that may already exist between patient populations.

Our exploratory analysis with an age-conditioned flow model provides a simpler illustration of why sampling choices deserve attention. With the model parameters and initial random noise held fixed, reducing the number of sampling steps changed the contrasts between age conditions in two image-derived measurements. The absolute contrast increased for one measurement and decreased for the other, while changing the placement of sampling steps also affected agreement with the higher-step reference. Appendix § 9 presents the figures, numerical results, and reported uncertainty estimates. However, these measurements have not been validated against independent clinical references, and the higher-step sampler provides a numerical comparison rather than a clinical ground truth. The findings therefore demonstrate sensitivity to the sampling procedure, but they do not establish unequal clinical errors or unfair outcomes across patient groups.

A patient-level evaluation would need to determine whether changes in sampling produce clinically meaningful increases in task error and whether those increases differ across groups. Intermediate generation states could then be examined to identify when clinically relevant information is lost or altered and whether those observations help predict which patient cases are most affected by faster sampling. To establish their practical value, such measurements should be compared with a strong endpoint-only evaluation using the same patients, clinical references, and held-out testing procedure. If intermediate states do not provide additional information about clinically relevant errors, evaluating the final outputs of the deployed sampler would remain the more appropriate approach.

Implications and limits

Fairness evaluation should clearly specify the system being tested, including the patient population, model checkpoint, sampling procedure, postprocessing, clinical task, reference standard, and subgroup definitions. Results obtained under one sampling procedure should not be assumed to hold when that procedure changes. Previous studies have shown that the reliability of clinical AI depends on implementation, external validation, clinical workflows, and changes after deployment [66, 69, 65, 19, 6]. The sampling procedure should therefore be considered part of the system being evaluated.

When the number or timing of sampling steps changes, the model should be evaluated using the same patient cases and appropriate clinical reference measurements. Comparisons should account for randomness and report task errors for each subgroup with uncertainty estimates. Differences relative to a reference sampler can identify changes caused by numerical sampling, but they do not establish clinical accuracy. Examining intermediate states may help explain where these changes arise and which stages contribute to errors. However, their usefulness should be assessed against endpoint-only evaluation, with appropriate statistical controls.

A reasonable question is whether evaluating the final outputs of the deployed sampler is sufficient. For a fixed sampling procedure that has been properly validated, this may be the case. Our concern is whether those findings remain valid when the sampling procedure changes or intermediate states are used elsewhere. If clinical task errors remain stable across sampling procedures, or examining intermediate states provides no additional information, further trajectory analysis may not be necessary.

Conclusion

Fairness evaluation for diffusion and flow-based models should consider the sampling procedure used to generate images and the clinical task those images are intended to support. Previous research has shown that sampling choices affect generation and that clinically relevant information may change throughout the process. Our mathematical example shows that equal outputs under one sampler do not guarantee equal outputs under another. These findings support evaluating clinical task errors across relevant sampling procedures and patient groups, with intermediate states examined when they help explain observed differences. Such evaluation can help determine whether changes in sampling affect the reliability of clinical measurements and whether those effects differ across patient groups.

Supplementary material

This supplement presents the detailed mathematical arguments and the additional figures from the exploratory sampling study. The study does not include independent clinical reference measurements, and the individual observations needed to check the reported confidence intervals and statistical tests were not available. We therefore use these results to examine sensitivity to the sampling procedure, not to establish differences in clinical error.

Age-conditioned sampling: an exploratory example

We examine an image flow model under two age conditions using 16 matched random seeds. The trained model is held fixed throughout. We compare a five-step sampler with a 40-step numerical reference. We also compare two schedules with ten steps each, placing more steps earlier or later in generation. The outputs are assessed using two image-derived quantities, Biomarker A and Biomarker B. Their clinical definitions, units, and independently measured targets are not available, so we treat them as proxy measurements. The 16 matched seeds represent paired generated samples, not 16 independent patients in either group. This design allows a controlled comparison of samplers for the conditional generator, but it cannot estimate how error varies across patients of different ages.

Let mrm_r denote the measurement of biomarker rr. The difference between age conditions aa and bb under sampling procedure π\pi is

Cr(π)=EZ[mr(Gθ,π(Z,b))−mr(Gθ,π(Z,a))],ΔCr=Cr(π)−Cr(π0).(4)C_r(\pi) = \mathbb{E}_Z\left[m_r(G_{\theta,\pi}(Z,b)) - m_r(G_{\theta,\pi}(Z,a))\right], \qquad\Delta C_r = C_r(\pi) - C_r(\pi_0). \tag*{(4)}

Here, π0\pi_0 is the reference sampler. This contrast measures differences between generated outputs, not errors against a clinical reference. It does not establish a causal effect of age. The change in a signed contrast, ΔCr\Delta C_r, must also be distinguished from the change in its magnitude, ∣Cr∣\lvert C_r\rvert.

Quantity∣Cr(40)∣\lvert C_r(40)\rvert∣Cr(5)∣\lvert C_r(5)\rvertReported ΔCr\Delta C_rReported 95% CIReported pp
Biomarker A0.02010.0328+0.0126[0.0066, 0.0193]0.0007
Biomarker B0.07780.0484+0.0294[0.0213, 0.0375]0.0002

Table 1. Biomarker contrasts under 40-step and five-step sampling. The first two numerical columns show the absolute differences between age conditions. The change, confidence interval, and pp-value are the reported values for the signed contrast. They could not be recalculated without the individual measurements.

Reducing sampling from 40 to five steps increased the absolute contrast for Biomarker A by approximately 63%, while the absolute contrast for Biomarker B decreased by approximately 38%. For Biomarker A, subtracting the displayed rounded values gives 0.0127, whereas the reported change is 0.0126. We retain the reported estimate because the unrounded measurements are unavailable. For Biomarker B, the positive signed change should not be confused with an increase in the absolute contrast, which became smaller. Without the signed group means or individual measurements, these results cannot support a stronger statistical interpretation. The intervals describe the uncertainty reported for generated samples. They should not be treated as patient-level confidence intervals, because changing random seeds is not the same as sampling different patients.

At a fixed budget of ten steps, placing more steps earlier in generation gave a smaller mean absolute deviation in Biomarker A from the 40-step reference than placing more steps later. The reported difference was 0.0079 (95% CI [0.0049, 0.0112]; p=0.0001p = 0.0001). This comparison concerns agreement with a numerical reference. Closer agreement with the 40-step output does not necessarily mean greater accuracy against an independent clinical measurement.

The study shows that the two image-derived measurements responded differently to changes in step count and schedule. However, the available results do not include patient-level observations, complete biomarker definitions, or independent clinical targets. The reported confidence intervals and pp-values have not been independently verified. The significance markers for the sampler-pair comparisons in Figure 5 are nominal and uncorrected for multiple comparisons. We therefore cannot determine whether the observed changes would produce clinically meaningful errors or unequal outcomes in patient groups.

Two heat maps showing group contrasts under different sampler comparisons

Figure 5. Group contrasts under different sampler comparisons. Each cell shows the change in an image-derived group contrast between a candidate sampler and a chosen reference. The heat maps show why a result obtained with one reference sampler cannot be assumed to describe every other comparison. The marked comparisons are nominal and uncorrected; they do not show patient-level fairness violations.

Additional data from the sampling study

Figure 2 shows the two age-conditioned comparisons. Figure 3 shows how the measured contrasts vary with the number of sampling steps. Figure 4 compares step placement and other changes to the generation procedure. Figure 5 compares contrasts obtained under different reference and candidate samplers. All four figures concern generated images and proxy measurements, not independently validated clinical outcomes.

Age-conditioned measurements under two samplers, showing generated images for Group 1 and Group 2 and comparisons of audited and deployed samplers

Figure 2. Age-conditioned measurements under two samplers. The generator uses the same trained weights and matched initial noise under a 40-step reference and a five-step sampler. The two image-derived group contrasts change in different directions. The images are illustrative generated outputs; they are not clinical reference images or evidence of unequal patient error.

Figure 3. Biomarker contrasts across sampling budgets. Biomarker A and Biomarker B respond differently as the number of steps changes. The displayed uncertainty bands and error bars come from the exploratory analysis and could not be independently checked without the individual observations. The curves do not measure clinical task error.

Figure 4. Changes in the sampling procedure. The panels compare solvers and step schedules (left), early and late allocation of ten sampling steps (middle), and the timing of an introduced conditional effect (right). Error bars describe variation across generated samples, not uncertainty across patients. The final panel examines model behavior and does not establish a clinical mechanism.

A mathematical counterexample to fairness transfer between samplers

Fix N≥2N \ge2 and consider two smooth scalar ODEs on 0≤t≤10 \le t \le1:

x˙g(t)=gKhN(t),xg(0)=0,hN(t)=1−2t+6N3N−1(t2−13),g∈{0,1}.(5)\dot{x}_g(t) = gK h_N(t), \qquad x_g(0) = 0, \qquad h_N(t) = 1 - 2t + \frac{6N}{3N-1}\left(t^2-\frac{1}{3}\right), \qquad g \in\{0,1\}. \tag*{(5)}

The drift does not depend on xx, and K>0K > 0 controls its scale. Since ∫01hN(t) dt=0\int_0^1 h_N(t)\,\mathrm{d}t = 0, both groups have exact endpoint zero. With kk uniform forward Euler steps, the difference between the numerical endpoints is

x^1(k)(1)−x^0(k)(1)=Kk∑j=0k−1hN(j/k).(6)\hat{x}^{(k)}_1(1)-\hat{x}^{(k)}_0(1)=\frac{K}{k}\sum_{j=0}^{k-1}h_N(j/k). \tag*{(6)}
1k∑j=0k−1(1−2jk)=1k,1k∑j=0k−1(j2k2−13)=−12k+16k2.\frac{1}{k}\sum_{j=0}^{k-1}\left(1-\frac{2j}{k}\right)=\frac{1}{k}, \qquad\frac{1}{k}\sum_{j=0}^{k-1}\left(\frac{j^2}{k^2}-\frac{1}{3}\right)=-\frac{1}{2k}+\frac{1}{6k^2}.

Substituting these sums gives

x^1(k)(1)−x^0(k)(1)=KN−kk2(3N−1).(7)\hat{x}^{(k)}_1(1)-\hat{x}^{(k)}_0(1)=K\frac{N-k}{k^2(3N-1)}. \tag*{(7)}

The endpoints agree when k=Nk=N. For any m≠Nm \ne N, the difference is nonzero. Choosing K≥Mm2(3N−1)/∣N−m∣K \ge M m^2(3N-1)/|N-m| makes its magnitude at least MM. Thus, equal exact endpoints and equal outputs under the NN-step reference sampler do not guarantee equal outputs under another step count. This proves Proposition 1 for the ODE construction. If both groups have target y∗=0y^*=0 and loss ∣x^g−y∗∣|\hat{x}_g-y^*|, group 0 has zero error, whereas group 1 has the absolute error in Eq. (7) under the changed sampler. This is a mathematical example, not a model of patient anatomy or disease.

Euler steps kkSigned differenceAbsolute difference
5+0.01176470.0117647
10+0.00252100.0025210
20+0.00042020.0004202
40 (reference)00
80−0.00005250.0000525

Table 2. Exact endpoint differences for N=40N = 40 and K=1K = 1. The groups agree under the continuous-time solution and the 40-step sampler, but not under the other step counts. All values are calculated from the equation, without clinical data.

Figure 6. Exact trajectories and numerical endpoints. The difference between the two exact trajectories returns to zero at the endpoint (left). Forward Euler gives a nonzero endpoint difference when the step count differs from the 40-step reference (right). The example uses no clinical data or trained model.

Extension to additive stochastic noise

Consider dXtg=gKhN(t) dt+σ dWt\mathrm{d}X_t^g = gK h_N(t)\,\mathrm{d}t + \sigma\,\mathrm{d}W_t, with identical initial conditions and diffusion coefficient for both groups. We use the same Brownian path for the two groups and across sampling grids. The exact drift difference integrates to zero at t=1t = 1, while the shared noise cancels when the group endpoints are subtracted. Under Euler–Maruyama, the Brownian increments on each grid sum to the same σW1\sigma W_1. The group difference is therefore still given by Eq. (7). This argument relies on shared additive noise. It does not give the same expression for independent noise, different group diffusion coefficients, or state-dependent diffusion. The choice of coupling must be stated when interpreting a stochastic comparison.

Why using intermediate states changes the system

Consider x˙g(t)=gK(1−2t)\dot{x}_g(t) = gK(1 - 2t) with xg(0)=0x_g(0) = 0. Its solution is xg(t)=gKt(1−t)x_g(t) = gKt(1 - t), so both groups have endpoint zero. At an intermediate time τ∈(0,1)\tau\in(0,1), however, their states differ by Kτ(1−τ)K\tau(1 - \tau), which is K/4K/4 when τ=1/2\tau= 1/2. A model that uses xτx_\tau for editing, distillation, or another task may therefore respond differently across groups even though the original final outputs agree. This explains why intermediate states can matter when they are used by another part of the system. A difference between intermediate states alone does not establish an error or unfairness.

A bound on changes in task error

Suppose fy(x)=ℓ(T(x),y)f_y(x) = \ell(T(x), y) is LfL_f-Lipschitz in xx for the relevant clinical references yy. Couple the outputs of two samplers for the same patient and random input. The change in standardized task risk for group gg is then bounded by the expected difference between their outputs:

∣Rg(π)−Rg(π0)∣≤Lf∫E[∥Gθ,π(U,Z)−Gθ,π0(U,Z)∥∣A=g,Q=q]w(q) dq.\lvert R_g(\pi) - R_g(\pi_0) \rvert\le L_f \int\mathbb{E}[\lVert G_{\theta,\pi}(U,Z) - G_{\theta,\pi_0}(U,Z) \rVert\mid A = g, Q = q]w(q)\,\mathrm{d}q.

Applying the triangle inequality to the two groups gives

∣D(π)−D(π0)∣≤Lf∑g∈{a,b}∫E[∥Gθ,π−Gθ,π0∥∣A=g,Q=q]w(q) dq.(8)\lvert D(\pi) - D(\pi_0) \rvert\le L_f \sum_{g \in\{a,b\}} \int\mathbb{E}[\lVert G_{\theta,\pi} - G_{\theta,\pi_0} \rVert\mid A = g, Q = q]w(q)\,\mathrm{d}q. \tag*{(8)}

This bounds the change in the subgroup task-error gap, not the gap itself. It also depends on the assumed smoothness of the loss. A small change in an image can produce a large change in a thresholded diagnosis, vessel connectivity, or topology, so the bound may not apply to those measurements.

A related bound holds for stochastic dynamics. Let dXtg=bg(t,Xtg) dt+σt dWt\mathrm{d}X_t^g = b_g(t, X_t^g)\,\mathrm{d}t + \sigma_t\,\mathrm{d}W_t, with identical initial conditions and shared additive noise. If ba(t,⋅)b_a(t,\cdot) is LbL_b-Lipschitz, then synchronous coupling gives

E∥X1b−X1a∥≤∫01eLb(1−s)E∥bb(s,Xsb)−ba(s,Xsb)∥ ds.\mathbb{E}\lVert X_1^b - X_1^a \rVert\le\int_0^1 e^{L_b(1-s)}\mathbb{E}\lVert b_b(s, X_s^b) - b_a(s, X_s^b) \rVert\,\mathrm{d}s.

To obtain this inequality, subtract the two equations, add and subtract ba(s,Xsb)b_a(s, X_s^b), and apply Gronwall’s inequality. The Wasserstein-1 distance between the endpoint distributions is at most the expected distance under this coupling. This is a mathematical stability result under specific assumptions, not a clinical fairness criterion. Path length and energy also depend on the choice of time scale, so their differences cannot be interpreted as unfairness on their own.

How to test the position with clinical data

A clinical evaluation should compare realistic sampling procedures on the same patients using independent task references, such as expert-labelled vessel segmentations or images obtained from an independent acquisition. The model checkpoint, patient inputs, and conditioning would remain fixed while the solver, step count, or step schedule changes. Randomness should be paired where the sampling methods permit it. For each subgroup, the study should report absolute task errors and uncertainty, then examine changes in those errors after adjustment for clinically justified variables. The samplers, outcomes, and acceptable error differences should be chosen before the analysis. For vascular tasks, useful outcomes might include segmentation error, vessel continuity, and deviation in vessel density. Each must have a clear clinical purpose, and thresholds or model settings should be selected without using the held-out test cases.

The additional value of intermediate states should be tested directly. One model could predict which patients have a clinically meaningful increase in error after acceleration using only endpoint information; a second could use the same information together with trajectory measurements. Both models should be trained and tuned on training patients, then evaluated on held-out patients with comparable access to data and model capacity. If trajectory measurements do not improve prediction, they are unlikely to justify routine use. If they do help, the findings should be tested across imaging devices, clinical sites, and patient populations. Stable subgroup errors across the samplers studied would support endpoint-only evaluation for that setting, even though the mathematical counterexample rules out a general guarantee across all samplers.

References

  1. [1]AI-READI Consortium. AI-READI: rethinking AI data collection, preparation and sharing in diabetes research and beyond. Nature Metabolism, 6:2210–2212, 2024.DOI
  2. [2]G. Alain and Y. Bengio. Understanding intermediate layers using linear classifier probes. arXiv:1610.01644, 2016.arXiv
  3. [3]Albergo, M. S., Boffi, N. M., & Vanden-Eijnden, E. (2025). Stochastic Interpolants: A Unifying Framework for Flows and Diffusions. Journal of Machine Learning Research, 26, 1–80.
  4. [4]V. Antun, F. Renna, C. Poon, B. Adcock, and A. C. Hansen. On instabilities of deep learning in image reconstruction and the potential costs of AI. Proceedings of the National Academy of Sciences, 117(48):30088–30095, 2020. doi:10.1073/pnas.1907377117.DOI
  5. [5]Aversa, M., Nobis, G., Hägele, M., Standvoss, K., Chirica, M., Murray-Smith, R., Alaa, A. M., Ruff, L., Ivanova, D., Samek, W., Klauschen, F., Sanguinetti, B., & Bruno, A. (2023). DiffInfinte: Large Mask-Image Synthesis via Parallel Random Patch Diffusion in Histopathology. Advances in Neural Information Processing Systems, Datasets and Benchmarks Track, 36.
  6. [6]Azad, Tej D., Krumholz, Harlan M. and Saria, Suchi. Principles to Guide Clinical AI Readiness and Move from Benchmarks to Real-World Evaluation. Nature Medicine, 32:802–804, 2026. doi:10.1038/s41591-025-04198-1.DOI
  7. [7]Bera, Kaustav, Schalper, Kurt A., Rimm, David L., Velcheti, Vamsidhar and Madabhushi, Anant. Artificial Intelligence in Digital Pathology—New Tools for Diagnosis and Precision Oncology. Nature Reviews Clinical Oncology, 16:703–715, 2019. doi:10.1038/s41571-019-0252-y.DOI
  8. [8]S. Bhadra, V. A. Kearl, F. J. Kelkar, F. J. Brooks, and M. A. Anastasio. On hallucinations in tomographic image reconstruction. IEEE Transactions on Medical Imaging, 40(11):3249–3260, 2021. doi:10.1109/TMI.2021.3077857.DOI
  9. [9]G. Biroli, T. Bonnaire, V. de Bortoli, and M. Mézard. Dynamical regimes of diffusion models. Nature Communications, 15:9957, 2024. doi:10.1038/s41467-024-54281-3.DOI
  10. [10]Brown, E. E., Guy, A. A., Holroyd, N. A., Sweeney, P. W., Gourment, L., Coleman, H., Walsh, C., Markaki, A. E., Shipley, R., Rajendram, N. S., & Walker-Samuel, S. (2024). Physics-informed deep generative learning for quantitative assessment of the retina. Nature Communications, 15(6859). https://doi.org/10.1038/s41467-024-50911-y
  11. [11]Chen, R. J., Wang, J. J., Williamson, D. F. K., & others, . and . (2023). Algorithmic Fairness in Artificial Intelligence for Medicine and Healthcare. Nature Biomedical Engineering, 7, 719–742. https://doi.org/10.1038/s41551-023-01056-8
  12. [12]J. Choi, J. Lee, C. Shin, S. Kim, H. Kim, and S. Yoon. Perception prioritized training of diffusion models. Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition, 11472–11481, 2022. https://arxiv.org/abs/2204.00227.
  13. [13]J. P. Cohen, M. Luck, and S. Honari. Distribution matching losses can hallucinate features in medical image translation. Medical Image Computing and Computer Assisted Intervention – MICCAI 2018, LNCS 11070:529–536, 2018. https://doi.org/10.1007/978-3-030-00928-1_60.
  14. [14]I. Coronado, S. Pachade, E. Trucco, R. Abdelkhaleq, J. Yan, S. Salazar-Marioni, A. Jagolino-Cole, M. Bahrainian, R. Channa, S. A. Sheth, and L. Giancardo. Synthetic OCT-A blood vessel maps using fundus images and generative adversarial networks. Scientific Reports, 13:15325, 2023. doi:10.1038/s41598-023-42062-9.DOI
  15. [15]Daneshjou, Roxana, Smith, Mary P., Sun, Mary D., Rotemberg, Veronica and Zou, James. Lack of Transparency and Potential Bias in Artificial Intelligence Data Sets and Algorithms: A Scoping Review. JAMA Dermatology, 157:1362–1369, 2021. doi:10.1001/jamadermatol.2021.3129.DOI
  16. [16]Y. Deo, Y. Jia, T. Lassila, W. A. P. Smith, T. Lawton, S. Kang, A. F. Frangi, and I. Habli. Metrics that matter: Evaluating image quality metrics for medical image generation. arXiv:2505.07175, 2025. Preprint. https://arxiv.org/abs/2505.07175.
  17. [17]M. Dohmen, M. A. Klemens, I. M. Baltruschat, T. Truong, and M. Lenga. Similarity and quality metrics for MR image-to-image translation. Scientific Reports, 15:3853, 2025. doi:10.1038/s41598-025-87358-0.DOI
  18. [18]Dombrowski, M., & Kainz, B. (2026). Can diffusion models generalize? Privacy and fairness trade-offs for medical data sharing. Medical Imaging with Deep Learning, 301, 366–392. https://proceedings.mlr.press/v301/dombrowski26a.htmlproceedings.mlr.press/v301/dombrowski26a.html
  19. [19]Administration, U. S. F. and D. (2025). Artificial Intelligence-Enabled Device Software Functions: Lifecycle Management and Marketing Submission Recommendations. In Draft Guidance for Industry and Food and Drug Administration Staff.
  20. [20]Friedrich, F., Brack, M., Struppek, L., Hintersdorf, D., Schramowski, P., Luccioni, S., & Kersting, K. (2023). Fair Diffusion: Instructing Text-to-Image Generation Models on Fairness. In arXiv preprint arXiv:2302.10853.arXiv
  21. [21]Y. Ganin, E. Ustinova, H. Ajakan, P. Germain, H. Larochelle, F. Laviolette, M. Marchand, and V. Lempitsky. Domain-adversarial training of neural networks. Journal of Machine Learning Research, 17(59):1–35, 2016. https://www.jmlr.org/papers/v17/15-239.html.jmlr.org/papers/v17/15-239.html
  22. [22]M. E. Gegúndez-Arias, A. Aquino, J. M. Bravo, and D. Marín. A function for quality evaluation of retinal vessel segmentations. IEEE Transactions on Medical Imaging, 31(2):231–239, 2012. doi:10.1109/TMI.2011.2167982.DOI
  23. [23]J. Ho, A. Jain, and P. Abbeel. Denoising diffusion probabilistic models. Advances in Neural Information Processing Systems, 33, 2020.arxiv.org/abs/2006.11239
  24. [24]X. Hu, F. Li, D. Samaras, and C. Chen. Topology-preserving deep image segmentation. Advances in Neural Information Processing Systems, 32, 2019. https://arxiv.org/abs/1906.05404.
  25. [25]Jin, Ruinan, Xu, Zikang, Zhong, Yuan, Yao, Qingsong, Dou, Qi, Zhou, S. Kevin and Li, Xiaoxiao. FairMedFM: Fairness Benchmarking for Medical Imaging Foundation Models. Advances in Neural Information Processing Systems, Datasets and Benchmarks Track, 37, 2024.arxiv.org/abs/2407.00983
  26. [26]T. Karras, M. Aittala, T. Aila, and S. Laine. Elucidating the design space of diffusion-based generative models. Advances in Neural Information Processing Systems, 35, 2022. https://arxiv.org/abs/2206.00364.
  27. [27]V. A. Kelkar, D. S. Gotsis, F. J. Brooks, P. KC, K. J. Myers, R. Zeng, and M. A. Anastasio. Assessing the ability of generative adversarial networks to learn canonical medical image statistics. IEEE Transactions on Medical Imaging, 42(6):1799–1808, 2023. doi:10.1109/TMI.2023.3241454.DOI
  28. [28]B. Kim, G. Kwon, K. Kim, and J. C. Ye. Unpaired image-to-image translation via neural Schrödinger bridge. International Conference on Learning Representations, 2024.arxiv.org/abs/2305.15086
  29. [29]Koetzier, L. R., Wu, J., Matrodascosa, D., Lutz, A., Koszek, W. A., Pratap, J., Chaudhari, A. S., Rajpurkar, P., Lungren, M. P., & Willemilk, M. J. (2024). Generating synthetic data for medical imaging. Radiology, 312(3), e232471. https://doi.org/10.1148/radiol.232471
  30. [30]Kuster, M. J., Russell, C., & Silva, R. (2017). Counterfactual fairness. In Advances in Neural Information Processing Systems (Vol. 30).
  31. [31]M. Li and S. Chen. Critical windows: non-asymptotic theory for feature emergence in diffusion models. International Conference on Machine Learning, PMLR 235:27474–27498, 2024.arxiv.org/abs/2403.01633
  32. [32]M. Li, A. Karan, and S. Chen. Blink of an eye: A simple theory for feature localization in generative models. International Conference on Machine Learning, PMLR 267:35047–35080, 2025. https://proceedings.mlr.press/v267/li25at.html.proceedings.mlr.press/v267/li25at.html
  33. [33]Z. Li, R. Zhang, Z. Tan, H. J. Aizenstein, J. Hu, and T. Chen. FairGen: preference-aligned diffusion for demographically equitable medical image synthesis. npj Digital Medicine, 9:740, 2026. doi:10.1038/s41746-026-02868-z.DOI
  34. [34]Y. Lipman, R. T. Q. Chen, H. Ben-Hamu, M. Nickel, and M. Le. Flow matching for generative modeling. International Conference on Learning Representations, 2023.arxiv.org/abs/2210.02747
  35. [35]Liu, Xingchao, Gong, Chengyue and Liu, Qiang. Flow Straight and Fast: Learning to Generate and Transfer Data with Rectified Flow. International Conference on Learning Representations, 2023.arxiv.org/abs/2209.03003
  36. [36]H. Liu, W. Zhang, J. Xie, F. Faccio, M. Xu, T. Xiang, M. Z. Shou, J.-M. Perez-Rua, and J. Schmidhuber. Faster diffusion via temporal attention decomposition. Transactions on Machine Learning Research, 2025. https://arxiv.org/abs/2404.02747.
  37. [37]C. Lu, Y. Zhou, F. Bao, J. Chen, C. Li, and J. Zhu. DPM-Solver: A fast ODE solver for diffusion probabilistic model sampling in around 10 steps. Advances in Neural Information Processing Systems, 35, 2022. https://arxiv.org/abs/2206.00927.
  38. [38]S. Luccioni, C. Akiki, M. Mitchell, and Y. Jernite. Stable Bias: Evaluating Societal Representations in Diffusion Models. Advances in Neural Information Processing Systems, Datasets and Benchmarks Track, 36, 2023. doi:10.52202/075280-2458.DOI
  39. [39]G. Luo, L. Dunlap, D. H. Park, A. Holynski, and T. Darrell. Diffusion hyperfeatures: Searching through time and space for semantic correspondence. Advances in Neural Information Processing Systems, 36, 2023. https://arxiv.org/abs/2305.14334.
  40. [40]Luo, Guanxiong, Huang, Shoujin and Uecker, Martin. Autoregressive Image Diffusion: Generation of Image Sequence and Application in MRI. Advances in Neural Information Processing Systems, 37, 2024.DOI
  41. [41]A. Madabhushi and G. Lee. Image analysis and machine learning in digital pathology: challenges and opportunities. Medical Image Analysis, 33:170–175, 2016.DOI
  42. [42]Ohayon, Guy, Elad, Michael and Michaeli, Tomer. Perceptual Fairness in Image Restoration. Advances in Neural Information Processing Systems, 37, 2024.arxiv.org/abs/2405.13805
  43. [43]D. Raghavan, K. V. Suma, and P. N. Ganesh. Assessment of neuroimaging data and identification of Alzheimer’s disease using extreme learning machines. Journal of Machine Learning for Modeling and Computing, 4(1):77–93, 2023. doi:10.1615/JMachLearnModelComput.2023048413.DOI
  44. [44]Raghavan, D., Rao, V., & S., S. S. (2026). AVID: A weakly aligned RGB-infrared dataset and perturbation benchmark for tiny aerial targets. In arXiv preprint arXiv:2610.40949. 2610.40949
  45. [45]Raghavan, D., Modanwal, G., Kar, S. S., Shiromani, S., AlBadri, A., Jain, N., Mehta, P. K., & Madabhushi, A. (2026). AI-derived OCTA retinal biomarkers detect coronary microvascular dysfunction in women. Journal of the American College of Cardiology, 87(Supplement), A790. https://doi.org/10.1016/j.jacc.2026.02.2038
  46. [46]Raghavan, D. (2026). Deductive constraint satisfaction vs. prevalence priors: Benchmarking LLM logic in clinical diagnostics. ICLR 2026 Workshop on Logical Reasoning of Large Language Models.
  47. [47]Raghavan, D., Singh, A., Kar, S. S., Chawla, R., & Madabhushi, A. (2026). Quality-aware deep learning improves prediction of best corrected visual acuity from retinal fundus images. Investigative Ophthalmology & Visual Science.
  48. [48]D. Raghavan, S. Sil Kar, S. Shiromani, A. AlBadri, N. Jain, P. K. Mehta, G. Modanwal, and A. Madabhushi. Retinal OCTA-derived microvascular remodeling is associated with coronary microvascular dysfunction in women with ischemia and no obstructive coronary artery disease: A pilot study. American Journal of Preventive Cardiology, 29:101671, 2026. doi:10.1016/j.ajpc.2026.101671.DOI
  49. [49]Raghavan, D., Singh, A., Modanwal, G., & Madabhushi, A. (2026). RetOncoMACE: An AI-informed cardio-oncology retinal signature for cardiovascular risk prediction in cancer patients. Journal of the American College of Cardiology, 87(Supplement), A1123. https://doi.org/10.1016/j.jacc.2026.02.2754
  50. [50]Raghavan, D., Madabhushi, A., Singh, A., Pathak, T., Corredor, G., Nooka, A. K., & Madabhushi, A. (2026). Sex-specific plasma-immune architectural differences in bone marrow predicts overall survival in multiple myeloma. Cancer Research, 86(7_Supplement), 5078. https://doi.org/10.1158/1538-7445.AM2026-5078
  51. [51]A. Sabour, S. Fidler, and K. Kreis. Align your steps: Optimizing sampling schedules in diffusion models. International Conference on Machine Learning, PMLR 235:42947–42975, 2024. https://proceedings.mlr.press/v235/sabour24a.html.arxiv.org/abs/2404.14507
  52. [52]Schrouff, J., Cessie, H., Koyejo, S., Alabdulmohsin, I. M., Schnider, E., Opsahl-Ong, K., Brown, A., Roy, S., Mincu, D., Chen, C., Dieng, A., Liu, Y., Natarajan, V., Karthikesalingam, A., Heller, K. A., Chiappa, S., & D’Amour, A. (2022). Diagnosing Failures of Fairness Transfer Across Distribution Shift in Real-World Medical Settings. Advances in Neural Information Processing Systems, 35.
  53. [53]Shen, Xudong, Du, Chao, Pang, Tianyu, Lin, Min, Wong, Yongkang and Kankanhalli, Mohan. Finetuning Text-to-Image Diffusion Models for Fairness. International Conference on Learning Representations, 2024.arxiv.org/abs/2311.07604
  54. [54]Shih, Andy, Belkhale, Suneel, Ermon, Stefano, Sadigh, Dorsa and Anari, Nima. Parallel Sampling of Diffusion Models. Advances in Neural Information Processing Systems, 36, 2023.arxiv.org/abs/2305.16317
  55. [55]S. Shit, J. C. Paetzold, A. Sekuboyina, I. Ezhov, A. Unger, A. Zhylka, J. P. W. Pluim, U. Bauer, and B. H. Menze. clDice—A novel topology-preserving loss function for tubular structure segmentation. Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition, 16560–16569, 2021. https://arxiv.org/abs/2003.07311.
  56. [56]Y. Skandarani, P.-M. Jodoin, and A. Lalande. GANs for medical image synthesis: An empirical study. Journal of Imaging, 9(3):69, 2023. doi:10.3390/jimaging9030069.DOI
  57. [57]J. Song, C. Meng, and S. Ermon. Denoising diffusion implicit models. International Conference on Learning Representations, 2021. https://arxiv.org/abs/2010.02502.
  58. [58]Y. Song, J. Sohl-Dickstein, D. P. Kingma, A. Kumar, S. Ermon, and B. Poole. Score-based generative modeling through stochastic differential equations. International Conference on Learning Representations, 2021.
  59. [59]G. Stein, J. C. Cresswell, R. Hosseinzadeh, Y. Sui, B. L. Ross, V. Villecroze, Z. Liu, A. L. Caterini, J. E. T. Taylor, and G. Loaiza-Ganem. Exposing Flaws of Generative Model Evaluation Metrics and Their Unfair Treatment of Diffusion Models. Advances in Neural Information Processing Systems, 36, 2023. doi:10.52202/075280-0165.DOI
  60. [60]N. Stucki, J. C. Paetzold, S. Shit, B. Menze, and U. Bauer. Topologically faithful image segmentation via induced matching of persistence barcodes. International Conference on Machine Learning, PMLR 202:32698–32727, 2023. https://proceedings.mlr.press/v202/stucki23a.html.proceedings.mlr.press/v202/stucki23a.html
  61. [61]K. V. Suma, D. Raghavan, and P. Ganesh. Deep learning for Alzheimer’s disease detection using multimodal MRI–PET fusion. 2022 4th International Conference on Circuits, Control, Communication and Computing (I4C), pp. 287–292, 2022. doi:10.1109/I4C57141.2022.10057623.DOI
  62. [62]S. Sun, G. M. Goldgof, A. Butte, and A. M. Alaa. Aligning synthetic medical images with clinical knowledge using human feedback. Advances in Neural Information Processing Systems, 36, 2023.arxiv.org/abs/2306.12438
  63. [63]Truong, K. L., Zimmermann, A., & Heidari, H. (2025). Toward Valid Measurement of (Un)fairness for Generative AI: A Proposal for Systematization. Proceedings of the AAAI/ACM Conference on AI, Ethics, and Society, 8(3), 2535–2549. https://doi.org/10.1609/aies.v8i3.36736
  64. [64]V. S. Viswanathan, V. Parmar, and A. Madabhushi. Towards equitable AI in oncology. Nature Reviews Clinical Oncology, 21:628–637, 2024.DOI
  65. [65]Organization, W. H. (2021). Ethics and Governance of Artificial Intelligence for Health: WHO Guidance. World Health Organization.
  66. [66]Wu, Eric, Wu, Kevin, Daneshjou, Roxana, Ouyang, David, Ho, Daniel E. and Zou, James. How Medical AI Devices Are Evaluated: Limitations and Recommendations from an Analysis of FDA Approvals. Nature Medicine, 27:582–584, 2021. doi:10.1038/s41591-021-01312-x.DOI
  67. [67]Wu, J., Fu, R., Fang, H., Zhang, Y., Yang, Y., Xiong, H., Liu, H., & Xu, Y. (2024). MedSegDiff: medical image segmentation with diffusion probabilistic model. In Medical Imaging with Deep Learning: PMLR 227 (pp. 1623–1639).
  68. [68]Yang, Y., Zhang, H., Gichoya, J. W., Katabi, D., & others. (2024). The Limits of Fair Medical Imaging AI in Real-World Generalization. Nature Medicine, 30, 2838–2848. https://doi.org/10.1038/s41591-024-03113-4
  69. [69]Zhang, Angela, Xing, Lei, Zou, James and Wu, Joseph C. Shifting Machine Learning for Healthcare from Development to Deployment and from Models to Data. Nature Biomedical Engineering, 6:1330–1345, 2022. doi:10.1038/s41551-022-00898-y.DOI
  70. [70]Zhou, Zhenyu, Chen, Defang, Wang, Can, Chen, Chun and Lyu, Siwei. Simple and Fast Distillation of Diffusion Models. Advances in Neural Information Processing Systems, 37, 2024.arxiv.org/abs/2409.19681
  71. [71]Singh, A., Kandwal, P., Kumar, A., & al., . et . (2025). AI-based early identification of nonresponders and surgical need in spinal tuberculosis via baseline MRI. The Spine Journal, 25(11), S50–S51. https://doi.org/10.1016/j.spinee.2025.08.278
  72. [72]A. Singh et al. CardioMorph Atlas: a statistical approach to evaluate association between pulmonary tuberculosis and cardiac morphology from chest X-rays. eBioMedicine, 130:106385, 2026. doi:10.1016/j.ebiom.2026.106385.DOI
  73. [73]Singh, A., Mohan, N., Lebowitz, M., Diwan, S., Azamat, S., Modanwal, G., & Madabhushi, A. (2026). Opportunistic heart, liver, and lung biological age acceleration as MACE risk predictor on cardiac MRI. Journal of the American College of Cardiology, 87(13 Suppl.), A1232–A1233. https://doi.org/10.1016/j.jacc.2026.02.3035
  74. [74]A. Singh, A. K. Nooka, G. Modanwal, N. Jain, M. V. Dhodapkar, S. Arepalli, S. Lonial, and A. Madabhushi. AI-informed retinal biomarkers predict 10-year risk of onset of multiple hematological malignancies. European Journal of Cancer, 229:115752, 2025. doi:10.1016/j.ejca.2025.115752.DOI

Paper details

vlnc:W_mya2hjwc
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 0

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Computer Science

Not recorded for this paper

View statement
Looking for related papers…
Contents