WorksPhysics and Astronomy
A discussion on the critical electric Rayleigh number for AC electrokinetic flow of binary fluids in a divergent microchannel
Abstract
Electrokinetic (EK) flow is a type of flow driven or manipulated by electric body forces, influenced by various factors such as electric field intensity, electric field form, frequency, electric permittivity/conductivity, fluid viscosity and etc. The diversity of dimensionless control parameters, such as the electric Rayleigh number, complicates the comparison of EK flow stability. Consequently, comparing the performance and cost of micromixers or reactors based on EK flow is challenging, posing an obstacle to their industrial and engineering applications. In this investigation, we theoretically derived a new electric Rayleigh number () that quantifies the relationship among electric body forces, fluid viscosity, and ion diffusivity, based on a tanh model of electric conductivity distribution. The calculation results indicate that the new exhibits richer variation with the control parameters and better consistency with previous experimental reports. We further conducted experimental studies on the critical electric Rayleigh number () of AC EK flow of binary fluids in a divergent microchannel. The experimental variations align well with the theoretical predictions, particularly the existence of an optimal AC frequency and electric conductivity ratio, demonstrating that the tanh model can better elucidate the underlying physics of EK flow. With the new electric Rayleigh number, we found that EK flow in the designed divergent microchannel has a much smaller than previously reported, indicating that EK flow is more unstable and thus more suitable for applications in micromixers or reactors in industry and engineering.
Introduction
Microfluidic device is a pivotal member of lab on a chip (LOC), facilitating the manipulation of fluids ranging from microliters to picoliters[1] in fields such as biomedical[2, 3, 4] and chemical engineering,[5, 6, 7, 8] including applications like polymerase chain reaction (PCR),[9] synthesis of nanoparticles[10] and DNA sequencing chips.[11]
Micromixer represents a significant category of microfluidic devices. According to the mechanism of mixing enhancement, micromixers are typically classified into two types: passive and active[12]. Passive micromixers enhance mixing through the folding and stretching of fluids within specially designed microchannel geometries, requiring no additional driving mechanisms beyond a pressure gradient to induce flow disturbance.[13, 14, 15, 16] While passive micromixers often have specific functions, they generally lack versatility and exhibit relatively low mixing efficiency. In 2002, Strootk et al.[17] introduced a staggered herringbone mixer, discovering that at a Péclet number of , the length required for 90% mixing was 7 mm, with the channel length needed for mixing increasing logarithmically with the Péclet number.
Active micromixers can significantly enhance mixing by applying external forces, such as electrostatic force,[18] Lorentz force[19] and acoustic pressure.20 Electrokinetic (EK) micromixer is a specific type of active micromixer that enhances mixing by EK flow driven by electrostatic force, and experiences a rapid advancement since 1990s.21 In 1998, Baygents et al.22 investigated the neutral stability curves for EK flow under a DC electric field that parallel to the electric conductivity interface. In their investigation, the status of EK flow is characterized by an electric Rayleigh number (, see Table I), which is determined by the electric intensity, the interface width and the gradient of electric conductivity. In @page 1/12 starts_mid=0 ends_mid=1
| Researchers | Baygents et al (1998) 22 | Chen et al (2005) 23 | Posner et al (2006) 24 | Wang et al (2014) 25 |
| Diagram of the EK flow | , , | , , , , | , , , , | , , |
| Researchers | Wu et al (2015) 26 | Yoshikawa et al (2015) 27 | Hassen et al (2020) 28 | Nan et al (2022) 21 |
| Diagram of the EK flow | The circular Couette flow; , | MWCNT-oil nanofluid; | , |
Table I. Definitions of in different EK flow model. The red arrow indicates the flow direction, while the green arrow indicates the direction of the electric field.
Introduction
Microfluidic device is a pivotal member of lab on a chip (LOC), facilitating the manipulation of fluids ranging from microliters to picoliters[1] in fields such as biomedical[2, 3, 4] and chemical engineering,[5, 6, 7, 8] including applications like polymerase chain reaction (PCR),[9] synthesis of nanoparticles[10] and DNA sequencing chips.[11]
Micromixer represents a significant category of microfluidic devices. According to the mechanism of mixing enhancement, micromixers are typically classified into two types: passive and active[12]. Passive micromixers enhance mixing through the folding and stretching of fluids within specially designed microchannel geometries, requiring no additional driving mechanisms beyond a pressure gradient to induce flow disturbance.[13, 14, 15, 16] While passive micromixers often have specific functions, they generally lack versatility and exhibit relatively low mixing efficiency. In 2002, Stroock et al.[17] introduced a staggered herringbone mixer, discovering that at a Péclet number of , the length required for 90% mixing was 7 mm, with the channel length needed for mixing increasing logarithmically with the Péclet number.
Active micromixers can significantly enhance mixing by applying external forces, such as electrostatic force,[18] Lorentz force[19] and acoustic pressure.20 Electrokinetic (EK) micromixer is a specific type of active micromixer that enhances mixing by EK flow driven by electrostatic force, and experiences a rapid advancement since 1990s.21 In 1998, Baygents et al.22 investigated the neutral stability curves for EK flow under a DC electric field that parallel to the electric conductivity interface. In their investigation, the status of EK flow is characterized by an electric Rayleigh number (, see Table I), which is determined by the electric intensity, the interface width and the gradient of electric conductivity. In
: Applied electric field; : Channel width; : Lower electric conductivity; : Higher electric conductivity; ; : Effective diffusivity; : Electric permittivity; : Dynamic viscosity; : Thermal diffusivity; : Interface width; : Channel height; : Electric conductivity ratio; : Ionic mobility; : Initial interface width; : Initial width at the inlet; : Characteristic length scale of the flow; : Temperature deviation; : Electric permittivity at reference temperature; : Coefficient; : Dimensionless number to evaluate the influence of frequency;
: Normalized maximum conductivity gradient;
2001, Oddy et al.29 designed a delicate micromixer to promote mixing through EK instability induced by sinusoidal electroosmotic flow. Subsequently, Lin et al.30 showed a plot of the growth rates of the most unstable eigenfunction in the wavenumber ()— space. They found the critical electric field required for mixing decreases as the electric conductivity ratio increases. In 2005, Chen et al.23 defined a (refer to Table I) for DC EK flow with electric conductivity difference in a T-shaped microchannel with a high aspect ratio. By experimental and analytical studies, they found the presence of both convective and absolute instabilities of EK flow. When the applied is beyond a certain critical threshold, say , the flow becomes convective unstable where the disturbance only grows downstream. When is beyond a second , the flow becomes absolute unstable, with the disturbances
propagating both upstream and downstream simultaneously. In 2006, Posner et al.31 studied the EK instability in a cross-shaped microchannel flow diagram. By defining a modified local electric Rayleigh number, characterized by the charge density as a function of the maximum electric conductivity gradients, they determined that the critical electric Rayleigh number .
In 2014, Wang et al. designed an elaborate Y-type EK micromixer[5] [25, 32] and demonstrated that micro electrokinetic (EK) turbulence could be generated under an alternating-current (AC) electric field with 100 kHz frequency. However, the additional control parameter, e.g. AC frequency, makes the comparison of working conditions with the previous reports unattainable. Further investigations by Nan et al.21 demonstrate that the conditions of inducing the most unstable mode of EK flow is inconsistent to that of generating highlydeveloped EK turbulence. This further indicates the difficulty to advance a universal control parameter for EK turbulence, e.g. electric Rayleigh number (). Although the deduced from the Zhao-Wang model33 can evaluate the flow status in a highly-developed AC EK turbulence, they are not appropriate indicators to show how the EK flow evolves from its initial status, which could be more crucial for engineering applications.
The strong diversity of dimensionless control parameters, e.g. , could be attributed to the broad factors that influencing the electric body force in EK flow, including the form, intensity and frequency of electric field, the geometry of the flow field, the distribution of electric conductivity and permittivity, pH value, electrode property and etc. The entangled dynamics and interfacial phenomenon make the problem more complicated to reach a common sense on the format of .
In this investigation, a novel that describing the transition of AC EK flow of binary fluids from stable to unstable states is theoretically analyzed and experimentally evaluated in a divergent microchannel. We focus on how is influenced by the physical and chemical conditions, e.g. electric field intensity, AC frequency, electric conductivity ratio and interface width. A theoretical analysis on electric Rayleigh number is conduct first. Then, the theory is adopted to predict the critical electric Rayleigh number of AC EK flow in a divergent microchannel. This study aims to show the newly developed electric Rayleigh number can better elucidate the underlying physics of how the electric body force perturbs the interface of the binary fluids. With the electric Rayleigh number, people can more precisely predict , facilitating the comparison of physical and chemical conditions of generating EK flow. This is important for enhancing our understanding of the mechanisms of EK turbulence and promoteing its application in microfluidics.
Theory and dimensionless parameters
Control equations
The EK flow can be described by Navier-Stokes equations as shown below34, 35
where is fluid density, is dynamic viscosity, is electric body force (EBF). and are electric permittivity and electric conductivity of the solution respectively, while is the charge density. The instantaneous velocity vector, , consist of , , as the velocity components in streamwise, spanwise and vertical directions respectively, where , and are the unit vectors in these corresponding directions. stands for the diffusion coefficient. Furthermore, we also assume the fluid to be incompressible, i.e. .
In this model, we consider that the electric field is perpendicular to the interface of the binary fluids, as diagramed in Figure 1, with the AC frequency () much higher than the response frequency () of the flow.36 The fluids share identical viscosity, temperature and electric permittivity, yet differ in electric conductivity, denoted as and ().
Figure 1. Schematic diagram of electric conductivity distribution along y direction in initial stage. denotes the width with electric conductivity . represents the interface width with electric conductivity gradient. is the width with electric conductivity . Note that, given the flow rate is the same, here .
Since the fluid is incompressible, .
Accordingly, (2) becomes
When an electric field is applied, initially, the interface between the binary fluids is slightly disturbed by the EBF. The ultrasmall flow disturbance has three consequences. First, the distribution of electric conductivity has negligible difference from the case without EBF. Second, the convective transport of charge is much weaker than that of the electric field. Therefore, the charge conservation equation37 becomes
The third is that the disturbance of electric conductivity is negligible as well. Consequently, the electric field can be approximated as a 1D model in the -direction, . Thus, Eq. (6) can be rewritten in the following as
where is the complex electric conductivity, with denoting the angular frequency. So considering the complex Ohmic law, , it is constant for where is complex electric current density.
Electric body force
In EK flow, EBF is the most important quantities that determines the state of flow, however, influenced by various factors. At the initial stage, the time-averaged AC EBF per unit volume can be rewritten as34
where is the complex conjugation of electric field intensity and is the real part. We are unable to use a local to evaluate the influence of EBF on EK flow. To characterize the influence of EBF, especially aiding to engineering applications, a spatially averaged EBF36 on the interface with a width of is applied as
where indicates the spatial averaging on in the direction. The complex current density is conserved in space as
where and are the complex electric conductivity and electric field intensity averaged on the interface with respectively. Similarly, and are the complex electric conductivity and electric field intensity averaged across the channel width respectively, where is the amplitude of the AC electric field and is the voltage amplitude between the two electrodes as shown in the Figure 1. Thus, . is strictly dependent on , and the spatial distribution of .
Here, we consider an initial case of the EK flow, where the EBF is too weak to induce a perturbation of . Thus, the distribution of can be approximated to be steady. Furthermore, we utilize a tanh distribution (Fig. 1) of electric conductivity to demonstrate how the EBF and the corresponding dimensionless parameters is influenced by the physical quantities. If the electric conductivity has a tanh distribution as below
where is a shape factor to characterize the distribution of . In the tanh model, to simulate an interface width of , approximately we have . According to Eq. (10), can be calculated as
Furthermore, according to and Eq. (10), we have
where is electric conductivity ratio, is a dimensionless frequency, , and . By substituting Eq. (12) into (8), with binomial expansion, we have
where , with and
| Linear model | Tanh model | |
| Schematic diagram of electric conductivity distribution | [Schematic diagram of electric conductivity distribution] | [Schematic diagram of electric conductivity distribution] |
| Electric conductivity distribution | ||
| <br><br> | <br><br><br><br> |
Table 2. Comparison between the linear model and the tanh model.
Electric Grashof number and electric Rayleigh number
The electric Grashof number and the electric Rayleigh number are two commonly used dimensionless parameters to describe the state of EK flow. The former represents the ratio of EBF relative to viscous force, while the latter further considers the influence of ion diffusion. According to Eq. (13), the electric Grashof number38 () can be quantified by
The electric Rayleigh number () is further obtained according to , where is Schmidt number. Then, we have
in Eq. (15) is evaluated from the overall distribution of electric conductivity. It complexly interplays with , and the initial distribution (through , and ) of electric conductivity, in a relatively nonintuitive manner. This is apparently distant from the previous investigations (see Table I), where the electric Rayleigh number are simply evaluated through either simple local quantities or a linear distribution of control scalars. For comparison, a linear model for electric conductivity distribution is also advanced in this investigation, as summarized in Table II.
Numerical calculation of in both linear and tanh model
In this section, as indicated by in the Table II, we demonstrate how the following parameters, e.g. , , and , contribute to the variations of . Both the linear mode and tanh model are theoretically compared to reveal their difference on calculating . To be consistent to experiments, some relevant parameters are given as: μm, is F/m, is kg/m, is m/s, is S/m and is m/s.
Electric conductivity ratio
First, the influence of on in the initial stage of EK flow is analyzed, as shown in Figure 2. Under the linear model, as depicted in Figure 2(a), increases rapidly and monotonically with increasing , eventually reaching a saturation point at . This indicates a higher probability of reaching an unstable state at higher , accordingly, easier to get into a transition. There is no optimal related to the highest in the linear model.

Figure 2. calculated from both linear and tanh models under different , where μm, μm and V/m, where is the diffusion time of the interface. Here, is the mean flow velocity at the centerline of the microchannel. is the measured position. All these data are consistent to the experimental conditions in the following. (a) calculated by the linear model vs . (b) calculated by the tanh model vs .
However, under the tanh model, first increases with and then decreases at relatively smaller , as depicted in Figure 2(b). This model provides us with the possibility of identifying an optimal to reach the highest , for effectively perturbing flow and improving momentum and scalar transport. Relative to the linear model without optimal , the tanh model that predicts optimal can provide better consistency with previous experiments. For instance, Wang et al.38 found when the applied AC frequency was 100 kHz, i.e. , an ultrafast EK mixing can be achieved with an optimal . Nan et al.21 also observed different optimal for perturbating the electric conductivity interface under different .
From Figure 2(b), it should be noted that only when (i.e. kHz), increases monotonically with . To avoid the violation of (where is the charge relaxation time)36, a larger exceeding is not applied in this study. In the range , we surprisingly find a special value of by the tanh model. When , is insensitive to .
AC frequency
The insensitivity of to at can be more visible in Figure 3(b). All the plots at are exactly flat lines in the wide range of . However, when , e.g. 2000 and 5400, changes significantly with . It stays almost unchanged with first, then rapidly increases until reaching another plateau.

Figure 3. calculated from both linear and tanh models under different , where μm, μm and V/m. (a) calculated by the linear model vs . (b) calculated by the tanh model vs .
In contrast, the variation of with is not observed in Figure 3(a), indicating the linear model has no capability to reveal the influence of (or AC frequency) on . This accounts for why in previous experiments21, even though ultrafast EK mixing can be observed at (or kHz), we still cannot get an apparently larger through the linear model.
Interface width
As illustrated by a series of investigations21, 22, 38, a larger gradient of electric conductivity is crucial for generating a larger EBF, accordingly a smaller is preferred. Thus, a smaller is corresponding to a larger . For this purpose, we theoretically studied the effect of on . As depicted in Figure 4, both models predict a larger with increasing as anticipated. The distinction lies in the fact that the tanh model can better distinguish the influence of , as can be observed in Figure 4(a, Figure 4b).
Figure 4. calculated from both linear and tanh models under different , where μm, and V/m. (a) calculated by the linear model vs . (b) calculated by the tanh model vs .
Electric field intensity
In contrast to , and which have complex relationship with , the quadratic effect of electric field
intensity is quite straightforward, i.e. according to Eq. (15). This is also observable from Figure 5(a, Figure 5b). The difference between the linear and tanh model is that the latter is distinguishable for different , while the former is not.

Figure 5. calculated from both linear and tanh models under different , where μm, and . (a) calculated by the linear model vs . (b) calculated by the tanh model vs .
Experimental setup and results
Experimental setup
In this section, relying on the electric Rayleigh number under the tanh model, we experimentally investigate the conditions when EK flow becomes unstable under AC electric field. To this end, the EK flow velocity is measured by laser induced fluorescence photobleaching anemometer (LIFPA), which has ultra-high spatial (~203 nm) and temporal (~4 μs) resolution, as diagramed in Figure 6(a). The system uses a 405nm continuous wave (CW) laser, with a laser power of 11 mW, as light source. An acousto-optic modulator (AOM) is applied to realize temporal control of the beam. The beam in turn passes through a special light filter (SLF) and a dichroic mirror (DM), and is then reflected into an objective lens (OL) to excite the fluorescent solution in the EK flow microchip. The fluorescent solution is Coumarin 102. The fluorescence emitted by the solution is filtered out by two bandpass filters (BP, 470/100 and 470/10 nm), collected by an optical fiber (OF), measured by a photon counter (PT) and finally processed by a computer (PC).

Figure 6. Experimental system. (a) The diagram of LIFPA system. Laser: 405 nm continuous wave laser, AOM: Acousto-optic modulator, SLF: Spatial light filter, M1 and M2: mirrors, DM: Dichroic mirror, BP1 and BP2: Bandpass filters, FM: flipping mount mirror, OF: Photon counter, PT: Photon counter, PC: computer, FG: Function generator, HVA: High voltage amplifier, SP: Syringe pump, OL: Objective lens, CMOS: camera. (b) Structure diagram of the chip. (c) Flow visualization of the pressure-driven basic flow without electric field. is the measurement position. is the velocity calibration position. (d) The spanwise distribution of velocity in when = 5 μL/min. (e) The velocity calibration in the center of channel. (f) The velocity time trace of = 1.8 × , = 5400 and = 11.4 μm.
The concentration of Coumarin102 solution is 100 μmol/L. It is prepared by anhydrous ethanol and deionized water. Phosphate buffer solution (PBS) is applied to adjust the electric conductivity of the two solutions to reach =1:5400, 1:2000, 1:200 and 1:2 respectively.
Figure 6(b) illustrates the schematic diagram of the EK flow microchip. The microchannel is 100 μm in high (), 18 mm in long and 650 μm in width between two electrodes. The two streams with different electric conductivity are injected separately from inlets 1 and 2 by a syringe pump. Consequently, a pronounced electrical conductivity gradient is established immediately following the trailing edge.
The measurement point ( in Figure 6(c)) is 150 μm downstream of the trailing edge. serves as the velocity calibration location, which is about 2 mm downstream of the trailing edge. At this position, the pressure-driven basic flow
is stable and fully developed. The velocity profile at the velocity calibration point is numerically simulated by COMSOL Multiphysics, as shown in Figure 6(d), to reveal the relationship between fluorescent intensity and velocity39. A velocity calibration curve is plotted in Figure 6(e). Figure 6(f) shows a typical velocity time trace.
Through the analysis and comparison of the above two models, it is clear that the tanh model contains richer and more complex information about the influence of , and on . To demonstrate the effectiveness of the tanh model, we studied the critical electric Rayleigh number (), when the EK flow becomes unstable, under different control parameters. is determined from the power spectrum () of the velocity fluctuations, as shown in Figure 7(a). When no electric field was applied, a peak in , referred to as , is observed attributing to the perturbation of the wake after the trailing edge. When a smaller AC electric field was applied, i.e. , is equivalent to that observed without electric field. While AC electric field is over some threshold value, , increases rapidly with , as plotted in Figure 7(b), indicating an amplification of the flow perturbation induced by EBF. Through this way, can be determined (Figure 7(b)).
Figure 7. Velocity power spectrum, and the determination of . (a) Velocity spectrum at , and . (b) vs showing the position of at .
Experimental results
The relevant experimental (the symbols) and theoretical (the dotted lines) results on are plotted in Figure 8, Figure 9 and Figure 10 respectively. First, we analyze the influence of on , as plotted in Figure 8. When , increases with first before subsequently decreasing in both experimental and theoretical results. Although the experimental one exhibits stronger bending relative to the theoretical one, their variation shows consistent trending. The consistency between experimental and theoretical results increases as increases, e.g. at . When , is monotonically increasing with . All the experimental trends align with the theoretical results predicted by the tanh model. In contrast, the most used model, i.e. linear distribution of , fails to provide even a qualitatively consistent prediction.
Figure 8. vs under different with .
Figure 9. vs under different with .
Figure 10. (a) vs under different with . (b) vs under different with .
Then, we further demonstrate the tanh model can effectively predict the influence of on . Both the experimental and theoretical results are plotted in Figure 9. The experimental results indicate, when , is almost unchanged with , which is consistent to the theoretical results. When , the tanh model further reveals the complex variation of with , such that keeps constant first, then increases until reaching a plateau. The results again support the effectiveness of the tanh model.
The parameter is crucial to the gradient of electric conductivity, which in turn, determines EBF and the corresponding electric Rayleigh number. From Figure 10(a), the experimental results of are monotonically increasing with , which is qualitatively consistent with the theoretical prediction by Eq. (15). Considering a larger is corresponding to a smaller electric conductivity gradient and smaller EBF, it indicates that the flow is more difficult to be disturbed at a larger under certain Reynolds number.
Finally, we also studied the influence of flow rate on , through bulk flow Reynolds number , where is the hydraulic diameter of the EK micromixers and is the bulk flow velocity. From Figure 10(b), it can be seen that has an inverse relationship with , indicating a decreasing requirement of AC electric field. Under a certain electric field, it is easier to generate unstable EK flow at a higher .
Discussion
Dimensionless parameters are vital for engineering applications where complex relations among multiple control parameters are interplayed. An effective dimensionless parameter that provides insight into the underlying relationship among the control parameters can also enhance our understanding of the complex physical mechanisms in an engineering system. Unfortunately, when more control parameters are taken into account, it is significantly difficult to reach an effective dimensionless parameter. Part of the researchers believe that the pursuit of universal dimensionless parameter could be meaningless.
From this investigation, we aspire to show that, if a complex dimensionless parameter is appropriately expressed, it not only evaluates the status of the system, but also predicts (even though qualitatively) how the system changes. By using a more accurate distribution of electric conductivity, i.e. tanh model, the existence of optimal and can be predicted through the electric Rayleigh number. The AC EK flow in a divergent microchannel can be unstable with . In contrast, the critical electric Rayleigh numbers in previous reports, e.g. Chen et al23 and Nan et al21, are estimated to be and respectively, if using the tanh model in this investigation.
On the other hand, it should be noted that the current experimental and theoretical results, e.g. on the influence of , still remain apparent discrepancies. This could be attributed to that the experimental environment is more complex relative to the theoretical model. of the electric conductivity interface varies along streamwise, making the electric conductivity distribution in experiments intrinsically 2D or more. To change , we change the flow rates of the two streams, which leads to the change of as well. It is almost impossible for us to isolate and from each other in experiments. Thus, discrepancies become inevitable.
Conclusion
In this investigation, we theoretically derive the expression of electric Rayleigh number for AC electrokinetic flow of binary fluids, on the basis of both linear and tanh distribution model of electric conductivity. The influence of electric conductivity ratio, AC frequency, interface width and electric field intensity on is systematically investigated in the tanh model, and compared with the linear model. Through comparison, it can be found that the tanh model provides more information about the variation of with the multiple parameters. In the tanh model, is more sensitive to electric conductivity ratio, AC frequency and interface width.
Furthermore, we conduct an experimental investigation on the critical electric Rayleigh number of the EK flow evaluated by the tanh model, through velocity measurement by LIFPA. The experimental findings exhibit an acceptable agreement with the theoretical predictions, thereby validating the efficacy of the electric Rayleigh number within the context of the tanh model.
An appropriate dimensionless parameter is not just a value, but an indicator of the underlying physical mechanism to guide engineering applications. In this paper, we propose a more accurate electric Rayleigh number to evaluate the state of AC EK flow, for designation of micromixers/reactors by electrokinetic approaches.
ACKNOWLEDGEMENTS
This research was funded by National Natural Science Foundation of China, grant number 51927804.
References
- [1]¹K. Karthikeyan, S. K. Kandasamy, P. Saravanan and A. Alodhayb, "Numerical simulation and parameter optimization of micromixer device using fuzzy logic technique," RSC Adv. 13, 4504-4522 (2023).DOI
- [2]²D. S. Kim, S. H. Lee, C. H. Ahn, J. Y. Lee and T. H. Kwon, "Disposable integrated microfluidic biochip for blood typing by plastic microinjection moulding," Lab Chip 6, 794-802 (2006).pubmed.ncbi.nlm.nih.gov/16738733
- [3]³V. E. Papadopoulos, I. N. Kefala, G. Kaprou, G. Kokkoris, D. Moschou, G. Papadakis, E. Gizeli and A. Tserepi, "A passive micromixer for enzymatic digestion of DNA," Microelectron. Eng. 124, 42-46 (2014).DOI
- [4]⁴Z. Geng, S. L. Li, L. X. Zhu, Z. Cheng, M. Jin, B. X. Liu, Y. Guo and P. Liu, "\"Sample-to-Answer\" Detection of Rare ctDNA Mutation from 2 mL Plasma with a Fully Integrated DNA Extraction and Digital Droplet PCR Microdevice for Liquid Biopsy," Anal. Chem. 92, 7240-7248 (2020).DOI
- [5]⁵S. S. Wang, Z. J. Li, S. Sheng, F. A. Wu and J. Wang, "Microfluidic biocatalysis enhances the esterification of caffeic acid and methanol under continuous-flow conditions," J. Chem. Technol. Biotechnol. 91, 555-562 (2016).DOI
- [6]⁶H. Z. Sun, Y. K. Ren, Y. Tao, T. Y. Jiang and H. Y. Jiang, "Three-Fluid Sequential Micromixing-Assisted Nanoparticle Synthesis Utilizing Alternating Current Electrothermal Flow," Ind. Eng. Chem. Res. 59, 12514-12524 (2020).DOI
- [7]⁷P. A. Auroux, D. Iossifidis, D. R. Reyes and A. Manz, "Micro total analysis systems. 2. Analytical standard operations and applications," Anal. Chem. 74, 2637-2652 (2002).pubmed.ncbi.nlm.nih.gov/12090654
- [8]⁸H. S. Santana, J. L. Silva, A. G. P. da Silva, A. C. Rodrigues, R. D. Amaral, D. Noriler and O. P. Taranto, "Development of a New Micromixer \"Elis\" for Fluid Mixing and Organic Reactions in Millidevices," Ind. Eng. Chem. Res. 60, 9216-9230 (2021).DOI
- [9]⁹C. Y. Lee and L. M. Fu, "Recent advances and applications of micromixers," Sens. Actuator B-Chem. 259, 677-702 (2018).DOI
- [10]¹⁰K. Illath, S. Kar, P. Gupta, A. Shinde, S. Wankhar, F. G. Tseng, K. T. Lim, M. Nagai and T. S. Santra, "Microfluidic nanomaterials: From synthesis to biomedical applications," Biomaterials 280, 33 (2022).DOI
- [11]¹¹G. Dutta, J. Rainbow, U. Zupancic, S. Papamathiou, P. Estrela and D. Moschou, "Microfluidic Devices for Label-Free DNA Detection," Chemosensors 6, 20 (2018).DOI
- [12]¹²X. Y. Chen and T. C. Li, "A novel passive micromixer designed by applying an optimization algorithm to the zigzag microchannel," Chem. Eng. J. 313, 1406-1414 (2017).DOI
- [13]¹³K. Karthikeyan, L. Sujatha and N. M. Sudharsan, "Numerical Modeling and Parametric Optimization of Micromixer for Low Diffusivity Fluids," Int. J. Chem. React. Eng. 16, 11 (2018).DOI
- [14]¹⁴M. Juraeva and D. J. Kang, "Mixing Enhancement of a Passive Micromixer with Submerged Structures," Micromachines 13, 15 (2022).DOI
- [15]¹⁵G. J. Liu, M. Wang, L. T. Dong, D. Y. Zhu, C. H. Wang, Y. H. Jia, X. B. Li and J. B. Wang, "A novel design for split-and-recombine micromixer with double-layer Y-shaped mixing units," Sens. Actuator A-Phys. 341, 8 (2022).DOI
- [16]¹⁶K. Karthikeyan and L. Sujatha, "Study of Permissible Flow Rate and Mixing Efficiency of the Micromixer Devices," Int. J. Chem. React. Eng. 17, 15 (2019).DOI
- [17]¹⁷A. D. Stroock, S. K. W. Dertinger, A. Ajdari, I. Mezic, H. A. Stone and G. M. Whitesides, "Chaotic mixer for microchannels," Science 295, 647-651 (2002).pubmed.ncbi.nlm.nih.gov/11809963
- [18]¹⁸H. Jalili, M. Raad and D. A. Fallah, "Numerical study on the mixing quality of an electroosmotic micromixer under periodic potential," Proc. Inst. Mech. Eng. Part C-J. Eng. Mech. Eng. Sci. 234, 2113-2125 (2020).
- [19]¹⁹D. Bahrami, A. A. Nadooshan and M. Bayareh, "Numerical study on the effect of planar normal and Halbach magnet arrays on micromixing," Int. J. Chem. React. Eng. 18, 11 (2020).DOI