Exact finite-sample and loss limits of squeezed-vacuum phase estimation
Abstract
We settle the dispute over squeezed-vacuum phase estimation by exact computation of the finite-sample errors, resource-fair scaling, phase window, and loss ceilings. A fixed overhead of ten repetitions sets the attainable finite-sample frontier; the repetitions cancel from the resource-fair bound, so Heisenberg scaling survives; the operating window holds a repetition-set number of resolvable points and needs one bit of branch prior; and fixed loss caps the per-photon advantage at a value set only by transmissivity, already reached by the reported record.
Introduction. Squeezed vacuum [1] combined with homodyne detection has recently been advanced as a deterministic route to Heisenberg-limited phase estimation: two experiments, one using direct homodyne detection of a single-mode squeezed vacuum [2] and one using a stimulated-emission nonlinear (SU(1,1)) interferometer [3] with on–off single-photon detectors [4], reported Fisher information per photon far above the standard quantum limit (SQL) and claimed a scalable, unconditional metrological advantage. Both claims have been challenged in a recent Comment by Hradil and Reháček [5], who argue that repetitions must be counted as resources, that the quantum Fisher information (QFI) is not by itself an operational benchmark, and that the advantage survives only in a phase window that shrinks with squeezing. A Reply [6] defends the original analysis.
The dispute has remained largely verbal because each side evaluates a different idealization of the same protocol. The purpose of this Letter is to compute, exactly and with no uncontrolled approximations, every quantity the dispute touches, and thereby to adjudicate each claim on its own terms. The protocol is simple enough that this program can be carried to completion: the phase is encoded in the variance of a zero-mean Gaussian distribution, the quadrature data admit a one-dimensional sufficient statistic, and the Bayesian posterior can be evaluated without Gaussian or Laplacian approximations. Loss can likewise be treated in closed form at both the homodyne-Fisher-information and exact-QFI levels, verified against an independent density-matrix calculation in the Fock basis.
Our conclusions are fourfold. (i) The Comment’s central resource-counting objection does not hold once the computation is exact: when the total photon number is held fixed, the number of repetitions cancels identically from the bound, so the Heisenberg scaling survives, with a prefactor that includes the finite- overhead. (ii) The Comment’s window criticism is quantitatively right and has a clean invariant form: the number of resolvable phase points inside the operating window is , independent of ; the advantage is therefore branch-conditional and not narrow-range, not “unconditional”. (iii) Neither side computed loss, and loss changes the story qualitatively: any fixed transmissivity caps the per-photon advantage at (homodyne) or (optimal measurement), so the quadratic per-photon growth ends at a plateau that depends only on . (iv) The two disputed experiments sit close to, and below, these ceilings.
Exact likelihood and finite-sample estimation. The probe is a squeezed vacuum with and quadratures , , satisfying . The phase shift rotates the quadratures, so the homodyne outcome at the optimal local oscillator angle is a zero-mean Gaussian random variable with variance
All phase information resides in the variance.
The parameter is a dynamical phase, not a Hamiltonian coupling: it enters through alone, so acts on the state family and not on any operator, and is invariant under mode-basis relabelings, local-oscillator phase choices, and gauge-like reparametrizations of the field. No ambiguity of the kind that afflicts estimates of a coupling strength arises; the only accounting freedoms left—the resource unit and the phase prior—are fixed explicitly below. For any zero-mean Gaussian distribution the classical Fisher information of a single sample is
which is maximized at with , i.e. at the operating point
where
which equals the QFI of the pure probe. Three independent evaluations—the analytic form (2), direct numerical integration of , and a Fock-space calculation of —agree to machine precision. Note that and : the operating point adjoins a zero-information point, which underlies everything that follows. Figure 1 plots this profile for several . The geometry is a wave-crest skin effect: as grows, the entire information crest piles up against the zero-information boundaries and , with crest position and width ; the boundary value stays pinned at zero, so this is a self-similar crest collapse (rising as , decaying as ) rather than a surface current.
Figure 1. (Color online) Homodyne Fisher information , Eq. (2), in units of its maximum , for (solid), (dashed), and (dash-dotted). Red dots mark the optimal operating points of Eq. (3) and their mirror images . The information vanishes at , peaks at [Eq. (3)], and the peak narrows as grows: the whole crest crowds against the zero-information boundaries and at width —a wave-crest skin effect. This profile generates the window and branch constraints quantified in the sections that follow.
Equation (4) is the resource statement in its standard form [7]: for unitary encoding, with the phase uncertainty, and for a pure probe [8], with and . The squeezed vacuum thus reaches Heisenberg scaling by making the spread of the generator linear in the photon number, not by any non-extensive generator: the growth of is the square of a linear , and nothing beyond the Heisenberg bound survives on the axis. It is this identification that loss breaks, as we show below.
For independent homodyne outcomes the joint likelihood depends on the data only through the sufficient statistic ,
so the exact finite- Bayesian posterior is one-dimensional and can be evaluated on a grid without approximation. Using the posterior mean as the estimator, Figure 2 shows the product , which equals unity when the Cramér–Rao bound (CRB) is attained.
Figure 2. (Color online) versus repetitions (exact Bayesian computation) for (circles, solid), (squares, dashed), and (triangles, dash-dotted); unity means the CRB is attained. The minimum sits near for every .
Two exact results follow. First, the CRB is approached once is of order ten: for the exact excess stays bounded, –, over (largest at small , reflecting the heavy-tailed posterior mean), and the threshold does not grow with . The reason is transparent from Eq. (5): the relative fluctuation of is governed by the distribution, whose width scales as independently of , while the phase curvature is absorbed in . Second, at the MSE exceeds the CRB by a factor of 8.3 () to 145 (): quantifying the Comment’s objection that a single-shot Fisher information is not an operational benchmark; the objection is real but bounded—the excess drops below 36% by and never grows with the resource.
Resource accounting: the repetitions cancel. The resource-fair comparison fixes the total photon number passing through the phase element. Whenever the CRB is valid (),
Adding repetitions with fewer photons each, or fewer repetitions with more photons each, yields the same total information—the algebraic refutation of the claim that counting repetitions restores the classical scaling. The only residue of finite statistics is the fixed overhead , which converts the single-shot value into the attainable frontier
where the arrow in Eq. (6) sets : because grows with , the optimum sits at the smallest admissible repetition number. Exact Bayesian evaluation at , , gives MSE , i.e. MSE , within 4% of —the residual being the finite-sample excess of Figure 2—and attaining the frontier (7). At this is 44 times below the SQL ; Figure 3 plots the frontier over six decades in . The Heisenberg scaling claimed in Refs. [2, 4] is therefore real, but the precise statement of it carries the prefactor 1.14 and the constraint —neither of which appears in the original claims, and neither of which destroys the scaling as the Comment argues.
Figure 3. (Color online) Resource-fair frontier: exact Bayesian computation of the attainable phase uncertainty versus total photon number (symbols), compared with the SQL (dashed) and the per-trial CRB (dash-dotted). The frontier follows the CRB over six decades in and lies 44 times below the SQL at .
Window, capacity, and the one-bit prior. The Comment’s strongest point is that the advantage occupies a shrinking phase window. Equation (2) vanishes at , and the full width at half maximum of is
verified numerically (ratio converging to 2.000). Combining Eqs. (3)–(8), the number of resolvable phase points inside the window is
independent of : squeezing sharpens the local readout () and narrows the window () in equal measure.
This is the precise version of the Comment’s “stopped clock” metaphor: the dial shrinks with the precision, and its information capacity is set by alone. Figure 4 verifies both power laws numerically. The variance (1) is -periodic and mirror-symmetric, , so the two branches are indistinguishable without prior information. With a flat prior on the posterior is exactly bimodal and the rms error worsens at by factors of 88 () to 480 () relative to the branch-resolved case. One bit of prior information—which the experiments supply by construction—restores the performance; since it does not scale with it affects constants, not scaling, but it belongs on the resource list: the advantage is branch-conditional and narrow-range, not “unconditional”.
Figure 4. (Color online) The shrinking window: numerically extracted full width of (at ) and the operating point , versus (log–log). Both follow the power law (dotted guide), confirming Eq. (8); the number of resolvable points inside the window, Eq. (9), is set by alone.
Loss: closed-form ceilings neither side computed. In metrology, loss is the standard route by which quantum enhancements are degraded [9]; here it is the ingredient neither side computed. A loss channel with transmissivity maps the zero-mean Gaussian probe to another zero-mean Gaussian state, so Eq. (2) still applies with
Maximizing Eq. (2) with Eq. (10) gives the homodyne Fisher information
while the exact QFI (12) of the mixed state, obtained from the covariance matrix with the purity correction and verified against an independent SLD (symmetric logarithmic derivative) computation in the Fock basis (agreement to machine precision for and to at , limited only by Fock truncation), is
At both reduce to ; for Eq. (12) exceeds Eq. (11), with the excess approaching 100% in the large- limit; homodyne reaches only 57% of the exact QFI at , (Table I)—a gap familiar from lossy Gaussian metrology [10, 11]—so the assumption that homodyne detection is optimal holds only for a pure probe.
For at fixed , and the quadratic growth terminates:
Against the coherent-state baseline at the same and loss, the plateaus (13) hard-cap the per-photon advantages at
independent of the probe; Figure 5 maps over the whole plane and shows the saturation geometry at a glance. At the homodyne advantage is exactly unity for all : substituting into Eq. (11) gives identically, a closed-form identity we verify numerically over . Squeezing below is strictly counterproductive for homodyne detection, while optimal measurement retains a factor-two advantage: the useful threshold is measurement-dependent.
Figure 5. (Color online) Per-photon advantage over a coherent probe at the same photon number and loss, over the plane of mean photon number and transmissivity (color scale). is a smooth function of both variables, rendered without contour levels, and grows monotonically with toward the ceiling of Eq. (14). Dash-dotted curve: 90% of the ceiling reached. White dashed line: , where the homodyne advantage is exactly unity for all (). Star: reported record of Ref. [2] (), already on the plateau.
The same construction settles the comparison between the two disputed protocols. With symmetric modes the two-mode squeezer factorizes, : the two-mode squeezed vacuum (TMSV) is a product of two single-mode squeezed vacua with the same , equal loss on and acts independently on each , and the generator is additive. Hence
| (SLD) | ||||
| 1.00 | 1.8 | 40.320 | 40.320 | 1.000 |
| 0.89 | 1.8 | 18.733 | 23.615 | 0.793 |
| 0.89 | 6.0 | 79.456 | 122.203 | 0.650 |
| 0.74 | 6.0 | 32.753 | 55.552 | 0.590 |
| 0.50 | 6.0 | 12.000 | 20.985 | 0.572 |
Table 1. Homodyne Fisher information versus exact QFI of the lossy probe (transmissivity , input ). The two coincide only at .
Eq. (15) reproduces at (with the total photon number)—the value quoted in Ref. [4]—and, dividing by the doubled photon number, gives exactly the same per-photon advantage curve as the single-mode protocol, not merely the same asymptote; Figure 6 displays the resulting ceiling structure. The two schemes are informationally equivalent per photon: they differ only in how loss is placed. An exact Fock-space SLD calculation shows that placing the loss in one arm changes the QFI by less than 13% relative to equal splitting of the same total transmissivity (–), so Eq. (14) applies to either loss placement.
Figure 6. (Color online) Per-photon advantage over a coherent probe at the same photon number and loss, versus (per mode). Colors distinguish the transmissivity: blue , orange , green , purple . Line styles distinguish the measurement: dashed, single-mode homodyne; dotted, optimal measurement, where the single-mode and two-mode (TMSV) curves coincide exactly [Eq. (15)]. Dash-dotted horizontal lines in the same colors: the ceilings of Eq. (14) for each —upper (optimal), lower (homodyne); solid black line: the SQL (unity). For each ceiling coincides with the asymptote of its curve, so dash-dotted line and curve overprint there. The homodyne curve sits exactly at unity for all —the threshold identity below Eq. (14).
The reported records sit on the plateau. The single-mode experiment reports per photon at a total loss of 11% [2]. The homodyne ceiling at is per photon: the reported record is at 97% of it, inside the error bar, and lies on the plateau of Eq. (14) under either reading of the normalization (largest probed photon number with , or with effective ). The nonlinear-interferometer experiment reports a 5.8(1)-fold enhancement [4], corresponding to the ceiling for an internal loss of 9%–17% depending on whether its on–off detection remains QFI-optimal under loss; either way, the enhancement cannot grow with squeezing. The advantage in both experiments is real but already saturated, and “Heisenberg-limited scaling” is a statement about the lossless model, not about the experiments.
Conclusions
We have given an exact, closed-form account of squeezed-vacuum phase estimation at every level the recent dispute appeals to. The repetitions cancel from the resource-fair bound, so the Comment’s central objection does not survive the exact computation; the window and branch criticisms are promoted to invariants, Eqs. (8)–(9) and the one-bit prior; and loss imposes ceilings (14) that the reported records already approach. The framework transfers verbatim to any protocol with the parameter encoded in a covariance matrix, including cavity-optomechanical coupling estimates, where the same finite-, window, branch, and loss analyses must accompany any QFI-based claim.
Acknowledgments
This work was supported by the National Natural Science Foundation of China (Grant No. 12205092), the Hunan Provincial Natural Science Foundation (Grant No. 2026JJ50100), and the Scientific Research Fund of the Hunan Provincial Education Department (Grant No. 24B0670).
References
- [1]C. M. Caves, Phys. Rev. D 23, 1693 (1981). doi:10.1103/PhysRevD.23.1693DOI
- [2]J. A. H. Nielsen, J. S. Neergaard-Nielsen, T. Gehring, and U. L. Andersen, Phys. Rev. Lett. 130, 123603 (2023). doi:10.1103/PhysRevLett.130.123603DOI
- [3]B. Yurke, S. L. McCall, and J. R. Klauder, Phys. Rev. A 33, 4033 (1986). doi:10.1103/PhysRevA.33.4033DOI
- [4]J. Qin et al., Phys. Rev. Lett. 130, 070801 (2023). doi:10.1103/PhysRevLett.130.070801DOI
- [5]Z. Hradil and J. Řeháček, arXiv:2609.15212 (2026). doi:10.48550/arXiv.2609.15212DOI
- [6]J. A. H. Nielsen, J. S. Neergaard-Nielsen, T. Gehring, and U. L. Andersen, arXiv:2611.16716 (2026). doi:10.48550/arXiv.2611.16716DOI
- [7]V. Giovannetti, S. Lloyd, and L. Maccone, Nat. Photonics 5, 222 (2011). doi:10.1038/nphoton.2011.35DOI
- [8]S. L. Braunstein and C. M. Caves, Phys. Rev. Lett. 72, 3439 (1994). doi:10.1103/PhysRevLett.72.3439DOI
- [9]R. Demkowicz-Dobrzański, J. Kołodyński, and M. Guţă, Nat. Commun. 3, 1063 (2012). doi:10.1038/ncomms2067
- [10]A. Monras and M. G. A. Paris, Phys. Rev. Lett. 98, 160401 (2007). doi:10.1103/PhysRevLett.98.160401DOI
- [11]O. Pinel, P. Jian, N. Treps, C. Fabre, and D. Braun, Phys. Rev. A 88, 040102(R) (2013). doi:10.1103/PhysRevA.88.040102DOI