betaFeedback

WorksPhysics and Astronomy

Analytic response functions of space-based gravitational-wave detectors to ultralight scalar-field dark matter under multiple types of TDI combinations

Abstract

Ultralight scalar fields are important candidates for dark matter. As coherently oscillating fields, they can leave characteristic signatures in space-based gravitational-wave detectors through their coupling to test masses. In this paper, we derive analytic expressions for the response functions of space-based gravitational-wave detectors to ultralight scalar-field dark matter under multiple types of time-delay interferometry (TDI) combinations. Starting from the coupling action between the scalar field and a test mass, we obtain the additional displacement of the test mass and the single-link Doppler response. We then give the general analytic form of the response function for an arbitrary TDI combination and compare the analytic and Monte Carlo numerical results for the optimal combinations A, E, and T. Finally, we analyze the responses of multiple types of TDI combinations, classify them into ordinary and ζ types according to their low-frequency behavior, and give the low-frequency response expressions of the individual combinations. The results can be used to evaluate the sensitivity of space-based gravitational-wave missions such as LISA, Taiji, and TianQin to the mass and coupling parameters of ultralight scalar-field dark matter.

Introduction

Dark matter (DM) is one of the major open problems in contemporary physics and astronomy. Galactic rotation curves provide evidence for an invisible matter component [1], while cosmological observations support a substantial non-baryonic matter density [2]. Within the base Λ\LambdaCDM model, DM accounts for approximately 26% of the total cosmic energy density [2]. Its microscopic nature remains unknown.

Complementary searches for particle DM include nuclear-recoil measurements [3, 4, 5] and searches for annihilation or decay products [6]. Ultralight scalar fields (ULSFs) motivate a different approach: their extremely large phase-space occupation allows a classical oscillating-field description [7, 8, 9, 10]. A linear coupling to the test-mass rest mass produces an oscillatory force, making precision interferometry a probe of this interaction [11, 12, 13].

Space-based gravitational-wave detectors measure relative test-mass motion through long-baseline laser interferometry. Missions such as LISA, Taiji, and TianQin target low-frequency gravitational-wave observations [14, 15, 16]. Their displacement measurements are also sensitive to non-gravitational forces associated with scalar DM. The resulting motion produces Doppler shifts in the laser links [17], complementing interferometric and precision-measurement searches [18, 19, 20, 21, 22, 23, 24, 25].

In an ideal equal-arm Michelson interferometer, common laser frequency fluctuations cancel in the differential readout. Unequal arms in a space-based detector sample those fluctuations at different retarded times, leaving residual laser noise in a simple arm difference. Time-delay interferometry (TDI) combines delayed one-way measurements to suppress this noise [26, 27, 28, 29]. Cancellation depends on the delay model and its accuracy. Residual secondary noises must also be propagated through each combination.

Previous work has studied scalar-field responses, velocity effects, and sensitivity estimates for elementary TDI combinations [17]. Geometric TDI provides a catalogue of 12-link, 14-link, and 16-link combinations and their delay-polynomial decompositions [30]. Building on these results, we derive analytic angular averages of the scalar response and verify them using independent numerical calculations. We then compare the 45 geometric combinations under a common static equal-arm model and noise prescription. The comparison distinguishes response equivalence from sensitivity equivalence and identifies where the low-frequency asymptotes apply.

The paper is organized as follows. Section II establishes the signal model of ultralight scalar-field dark matter in space-based gravitational-wave detectors and derives the single-link response. Section III gives the analytic TDI response expressions and their numerical verification. Section IV compares the responses and sensitivities of different TDI combinations and discusses their application to coupling estimates. Section V summarizes the paper. We adopt natural units with c=ℏ=1c=\hbar=1 and restore cc where lengths and frequencies are given in SI units.

Principles of dark matter detection with space-based gravitational-wave detectors

To connect the scalar-field interaction to a measurable signal, we first specify the coupling to matter using the effective Lagrangian. We then derive the motion induced in a test mass by the oscillating field and use the resulting displacement to calculate the Doppler response of a single laser link.

Action of dark matter

We consider an ultralight scalar field as a dark matter candidate and adopt a description in which ϕ\phi couples linearly to Standard Model fields. The effective Lagrangian in the low-energy limit is [7, 8, 9, 10, 31]:

L=Lϕ+LSM+Lϕ−SM.(1)\mathcal{L}=\mathcal{L}_{\phi}+\mathcal{L}_{\mathrm{SM}}+\mathcal{L}_{\phi-\mathrm{SM}} . \tag*{(1)}

Here LSM\mathcal{L}_{\mathrm{SM}} is the Standard Model Lagrangian, Lϕ\mathcal{L}_{\phi} describes a scalar field of mass mϕm_{\phi}, and Lϕ−SM\mathcal{L}_{\phi-\mathrm{SM}} describes its interactions with matter. The latter two terms are given by

Lϕ=−12∂μϕ∂μϕ−12mϕ2ϕ2,(2)\mathcal{L}_{\phi}=-\frac{1}{2}\partial_{\mu}\phi\partial^{\mu}\phi-\frac{1}{2}m_{\phi}^{2}\phi^{2}, \tag*{(2)}

and

Lϕ−SM=κϕ[de4e2FμνFμν−dgβ32g3GμνAGAμν−∑i=e,u,d(dmi+γmidg)miψˉiψi],(3)\mathcal{L}_{\phi-\mathrm{SM}}=\kappa\phi\left[\frac{d_{e}}{4e^{2}}F_{\mu\nu}F^{\mu\nu}-\frac{d_{g}\beta_{3}}{2g_{3}}G_{\mu\nu}^{A}G^{A\mu\nu}-\sum_{i=e,u,d}(d_{m_i}+\gamma_{m_i}d_g)m_i\bar{\psi}_i\psi_i\right], \tag*{(3)}

where κ≡4πG=4π/MP\kappa\equiv\sqrt{4\pi G}=\sqrt{4\pi}/M_{\mathrm{P}}, GG is Newton's constant, and MP=G−1/2M_{\mathrm{P}}=G^{-1/2} is the Planck mass. The tensors FμνF_{\mu\nu} and GμνAG_{\mu\nu}^{A} describe the electromagnetic and gluon fields, respectively, with AA a gluon color index. Here ee and g3g_3 are the electromagnetic and strong gauge couplings, β3\beta_3 is the beta function of quantum chromodynamics (QCD), and γmi\gamma_{m_i} are the fermion mass anomalous dimensions. The dimensionless coefficients ded_e, dgd_g, and dmid_{m_i} parameterize the scalar couplings to these fields and to the fermion mass terms. The fields ψi\psi_i, with masses mim_i, represent the electron and the uu and dd quarks, and ψˉi\bar{\psi}_i are their Dirac adjoints. The quark couplings can also be expressed as

dm^=dmdmd+dmumumd+mu,d_{\hat{m}}=\frac{d_{m_d}m_d+d_{m_u}m_u}{m_d+m_u},
dδm=dmdmd−dmumumd−mu.(4)d_{\delta m}=\frac{d_{m_d}m_d-d_{m_u}m_u}{m_d-m_u}. \tag*{(4)}

dm^d_{\hat{m}} denotes the coupling to the average quark mass, and dδmd_{\delta m} denotes the coupling related to the quark mass difference. For a macroscopic test mass, the scalar coupling enters through the field dependence of its mass m(ϕ)m(\phi). This field dependence of m(ϕ)m(\phi) determines the motion of the test mass in the scalar field.

Principle of dark matter detection with space-based gravitational-wave detectors

The classical scalar field admits a plane-wave decomposition in the free-field approximation. To calculate the response for a fixed field velocity, we consider one monochromatic mode,

ϕ(t,x⃗)=ϕk⃗ei(ωt−k⃗⋅x⃗+θ0),(5)\phi(t,\vec{x})=\phi_{\vec{k}}e^{i(\omega t-\vec{k}\cdot\vec{x}+\theta_0)}, \tag*{(5)}

where ϕk⃗\phi_{\vec{k}} is the amplitude, ω\omega the angular frequency, k⃗\vec{k} the momentum vector, and θ0\theta_0 the initial phase (whose value does not affect the discussion and can be set to zero). When the scalar field constitutes Galactic dark matter, its velocity dispersion is v∼10−3v\sim10^{-3}, corresponding to non-relativistic fluctuations with k⃗≈mϕv⃗\vec{k}\approx m_{\phi}\vec{v} and ω≈mϕ\omega\approx m_{\phi}. The test-mass response to this field follows from the action

S=−∫m(ϕ)−ημνdxμdxν.(6)S=-\int m(\phi)\sqrt{-\eta_{\mu\nu}dx^{\mu}dx^{\nu}}. \tag*{(6)}

We neglect gravitational effects and describe the test mass by a field-dependent mass m(ϕ)m(\phi). The Minkowski metric ημν\eta_{\mu\nu} has signature (−,+,+,+)(-,+,+,+). Greek indices label spacetime components and ii labels a spatial component. To derive the equation of motion, we use dxμ=(dt,dx⃗)dx^{\mu}=(dt,d\vec{x}) and temporarily denote the test-mass velocity by v⃗=dx⃗/dt\vec{v}=d\vec{x}/dt, with v2=v⃗⋅v⃗v^{2}=\vec{v}\cdot\vec{v}. The proper-time element then satisfies

−ημνdxμdxν=dt2(1−v2).(7)-\eta_{\mu\nu}dx^{\mu}dx^{\nu}=dt^{2}(1-v^{2}). \tag*{(7)}

Writing the action as S=∫L dtS=\int L\,dt gives the point-particle Lagrangian

L=−m(ϕ)1−v2.(8)L=-m(\phi)\sqrt{1-v^{2}}. \tag*{(8)}

Substituting the Lagrangian into the Euler–Lagrange equation and taking the non-relativistic limit gives

d2xidt2≈−κα(ϕ)(∂iϕ+ϕ˙dxidt).(9)\frac{d^{2}x^{i}}{dt^{2}}\approx-\kappa\alpha(\phi)\left(\partial_i\phi+\dot{\phi}\frac{dx^{i}}{dt}\right). \tag*{(9)}

Here, α=1κ2m(ϕ)[∂[κm(ϕ)]∂ϕ]\alpha=\frac{1}{\kappa^{2}m(\phi)}\left[\frac{\partial[\kappa m(\phi)]}{\partial\phi}\right] characterizes the scalar coupling to the test mass [32, 33, 34]. For an initially stationary test mass, the second term is higher order in the coupling than the first and can be neglected at linear order. The scalar field then induces the acceleration

ai(t,x⃗)=iϕk⃗ακkieimϕ(t−v⃗⋅x⃗).(10)a^{i}(t,\vec{x})=i\phi_{\vec{k}}\alpha\kappa k^{i}e^{im_{\phi}(t-\vec{v}\cdot\vec{x})}. \tag*{(10)}

Integrating the oscillatory acceleration twice gives the induced displacement,

δxi(t,x⃗)=−iMsk^ieimϕ(t−v⃗⋅x⃗),(11)\delta x^{i}(t,\vec{x})=-i\mathcal{M}_{s}\hat{k}^{i}e^{im_{\phi}(t-\vec{v}\cdot\vec{x})}, \tag*{(11)}

where Ms=ακϕk⃗∣k⃗∣/mϕ2\mathcal{M}_{s}=\alpha\kappa\phi_{\vec{k}}|\vec{k}|/m_{\phi}^{2} sets the displacement amplitude. The induced displacements of the sending and receiving test masses change the light-travel time and hence the measured laser frequency.

Form of the response of the space-based detector to dark matter

We now obtain the laser-frequency signal from the test-mass displacement, accounting for the light-travel time between spacecraft. We use the link geometry in figure 1. The spacecraft are labeled SC1, SC2, and SC3. Here $\alpha and β\beta are the geometric angles between the xx axis and the arms SC1–SC2 and SC1–SC3, respectively. The arm opposite SCii has length LiL_i. The position vectors of the three satellites are:

Figure 1. Schematic diagram of the geometry of the triangular space-based detector.

x⃗1=(0,0,0),x⃗2=L3(cos⁡(α),sin⁡(α),0),x⃗3=L2(cos⁡(β),−sin⁡(β),0).(12)\begin{aligned} \vec{x}_1 &= (0,0,0),\\ \vec{x}_2 &= L_3(\cos(\alpha),\sin(\alpha),0),\\ \vec{x}_3 &= L_2(\cos(\beta),-\sin(\beta),0). \tag*{(12)} \end{aligned}

Accordingly, the direction vectors along the arms are defined as:

n^12=1L3(x⃗2−x⃗1)=(cos⁡(α),sin⁡(α),0),n^23=1L1(x⃗3−x⃗2)=(L2cos⁡(β)−L3cos⁡(α)L1,−L2sin⁡(β)−L3sin⁡(α)L1,0),n^31=1L2(x⃗1−x⃗3)=(−cos⁡(β),sin⁡(β),0).(13)\begin{aligned} \hat{n}_{12} &= \frac{1}{L_3}(\vec{x}_2-\vec{x}_1)=(\cos(\alpha),\sin(\alpha),0),\\ \hat{n}_{23} &= \frac{1}{L_1}(\vec{x}_3-\vec{x}_2)\\ &=\left(\frac{L_2\cos(\beta)-L_3\cos(\alpha)}{L_1},\frac{-L_2\sin(\beta)-L_3\sin(\alpha)}{L_1},0\right),\\ \hat{n}_{31} &= \frac{1}{L_2}(\vec{x}_1-\vec{x}_3)=(-\cos(\beta),\sin(\beta),0). \tag*{(13)} \end{aligned}

The angles θ\theta and ϕ\phi specify the field propagation direction in spherical coordinates. The corresponding unit vector k^\hat{k} and wave vector k⃗\vec{k} are

k^=(sin⁡θcos⁡ϕ,sin⁡θsin⁡ϕ,cos⁡θ),k⃗=2πfcv(sin⁡θcos⁡ϕ,sin⁡θsin⁡ϕ,cos⁡θ).(14)\begin{aligned} \hat{k} &= (\sin\theta\cos\phi,\sin\theta\sin\phi,\cos\theta),\\ \vec{k} &= \frac{2\pi f}{c}v(\sin\theta\cos\phi,\sin\theta\sin\phi,\cos\theta). \tag*{(14)} \end{aligned}

With the link directions specified, we substitute the induced displacements into the light-travel-time perturbation. For a link received at SCr and emitted at SCs, the propagation time TrsT_{rs} is

Trs=Lrs+δtrs,(15)T_{rs}=L_{rs}+\delta t_{rs}, \tag*{(15)}

where LrsL_{rs} is the unperturbed light-travel time in natural units and δtrs\delta t_{rs} is its perturbation. The unit vector n^rs\hat{n}_{rs} points from receiver to sender. In the equal-arm expressions below, the common delay is LL, so the displacement perturbation is

δtrs=−n^rs⋅[δx⃗(t,x⃗r)−δx⃗(t−L,x⃗s)].(16)\delta t_{rs}=-\hat{n}_{rs}\cdot[\delta\vec{x}(t,\vec{x}_r)-\delta\vec{x}(t-L,\vec{x}_s)]. \tag*{(16)}

This perturbation changes the received laser phase according to

ϕr(t)=ϕs(t−Trs)=2πν0(t−Lrs−δtrs),(17)\phi_r(t)=\phi_s(t-T_{rs})=2\pi\nu_0(t-L_{rs}-\delta t_{rs}), \tag*{(17)}

where ν0\nu_0 is the reference laser frequency and ϕs\phi_s, ϕr\phi_r denote the emitted and received laser phases. The received instantaneous frequency is

νrs(t)=12πdϕrdt.(18)\nu_{rs}(t)=\frac{1}{2\pi}\frac{d\phi_r}{dt}. \tag*{(18)}

Writing δνrs=νrs−ν0\delta\nu_{rs}=\nu_{rs}-\nu_0, the phase derivative gives the relative frequency shift

δνrsν0=−dδtrsdt.(19)\frac{\delta\nu_{rs}}{\nu_0}=-\frac{d\delta t_{rs}}{dt}. \tag*{(19)}

Substituting the test-mass displacement gives the single-link Doppler response in the unified form [35]:

yrs(t)=δνrsν0=μrs[h(t,x⃗r)−h(t−L,x⃗s)].(20)y_{rs}(t)=\frac{\delta\nu_{rs}}{\nu_0}=\mu_{rs}[h(t,\vec{x}_r)-h(t-L,\vec{x}_s)]. \tag*{(20)}

where h(t,x⃗)=mϕMseimϕ(t−vk^⋅x⃗)h(t,\vec{x})=m_\phi\mathcal{M}_s e^{i m_\phi(t-v\hat{k}\cdot\vec{x})} is the scalar-signal amplitude used to normalize the response and μrs=k^⋅n^rs\mu_{rs}=\hat{k}\cdot\hat{n}_{rs} is the projection along the link. For the field at the origin, h(t)≡h(t,0⃗)h(t)\equiv h(t,\vec{0}), we use the temporal Fourier convention

h(t)=12π∫−∞∞h~(ω)eiωt dω.(21)h(t)=\frac{1}{2\pi}\int_{-\infty}^{\infty}\widetilde{h}(\omega)e^{i\omega t}\,d\omega. \tag*{(21)}

A finite observation of duration TT is described by h~T(ω)=∫0Th(t)e−iωt dt\widetilde{h}_T(\omega)=\int_0^T h(t)e^{-i\omega t}\,dt. Substituting into Eq. (20) gives:

yrs(t)=μrs12π∫−∞∞dω h~(ω)eiωt[e−ik⃗⋅x⃗r−e−i(τ+k⃗⋅x⃗s)].(22)y_{rs}(t)=\mu_{rs}\frac{1}{2\pi}\int_{-\infty}^{\infty}d\omega\,\widetilde{h}(\omega)e^{i\omega t}\left[e^{-i\vec{k}\cdot\vec{x}_r}-e^{-i(\tau+\vec{k}\cdot\vec{x}_s)}\right]. \tag*{(22)}

where τ=2πfL/c\tau=2\pi fL/c. The response expression for a single link is then obtained as

y~rs(ω)=μrsh~(ω)(e−i(k⃗⋅x⃗r)−e−i(τ+k⃗⋅x⃗s)),(23)\widetilde{y}_{rs}(\omega)=\mu_{rs}\widetilde{h}(\omega)\left(e^{-i(\vec{k}\cdot\vec{x}_r)}-e^{-i(\tau+\vec{k}\cdot\vec{x}_s)}\right), \tag*{(23)}

where μrs=k^⋅n^rs\mu_{rs}=\hat{k}\cdot\hat{n}_{rs}. This single-link frequency-domain response provides the input for constructing TDI observables from delayed one-way measurements.

Response functions of dark matter under multiple types of TDI combinations

Starting from the single-link Doppler response derived above, we construct TDI observables by combining delayed measurements. In this section, we express the direction-averaged power response in terms of six delay coefficients and verify the analytic results for A, E, and T by numerical angular integration.

Time-delay interferometry combinations

TDI observables suppress laser frequency noise [26, 27, 28, 29]. The chosen delay model determines the order to which laser noise is cancelled. Any TDI combination is therefore completely characterized by a set of delay polynomials, namely the coefficients of the individual single-link responses and the corresponding time delays. As an example, figure 2 shows the two synthesized light paths of the equal-arm Michelson XX combination. Each arrow contributes a one-way measurement. A one-arm delay is D=e−iuD=e^{-iu}, with u=2πfL/c=τu=2\pi fL/c=\tau. Each additional one-arm light-travel delay introduces another factor of DD, so path b minus path a gives

X=(1−D2)(y13+Dy31−y12−Dy21).(24)X=(1-D^2)(y_{13}+Dy_{31}-y_{12}-Dy_{21}). \tag*{(24)}

The commonly used elementary combinations belong to first-generation TDI. The Michelson combinations X, Y, and Z each take one spacecraft as the vertex and compare round trips along its two arms. The Sagnac combinations α\alpha, β\beta, and γ\gamma correspond to closed loops around the three spacecraft. Other elementary combinations include the Beacon combinations P, Q, and R, the Monitor combinations E, F, and G, and the Relay combinations U, V, and W [27, 29]. Orthogonal linear combinations of X, Y, and Z give the combinations A, E, and T. Under symmetric noise assumptions these are noise-orthogonal; the T response is suppressed in the long-wavelength limit for gravitational waves, but it is not an exactly signal-free channel [30, 36]. Under the equal-arm approximation, some differently named combinations have identical responses. In this paper we extend the elementary combinations above to geometric 12-link, 14-link, and 16-link TDI combinations [30] and derive analytic expressions for their response functions. To treat these combinations in a common framework, we express the response in terms of their six delay-polynomial coefficients.

Analytic calculation of the response function

In yrsy_{rs}, r,s∈{1,2,3}r,s\in\{1,2,3\} label the receiving and transmitting spacecraft, respectively, with r≠sr\ne s. We use the six-link order (y12,y23,y31,y13,y21,y32)(y_{12},y_{23},y_{31},y_{13},y_{21},y_{32}) with coefficients (P1,P2,P3,P1′,P2′,P3′)(P_1,P_2,P_3,P_1',P_2',P_3'). We denote by TDI(ω)\mathrm{TDI}(\omega) the TDI observable specified by these coefficients. Its direction-averaged power response is [17, 29, 30]

RTDI(ω)=14π∫−11dcos⁡θ∫02πdϕ∣TDI~(ω)h~(ω)∣2.(25)R_{\mathrm{TDI}}(\omega)=\frac{1}{4\pi}\int_{-1}^{1}d\cos\theta\int_{0}^{2\pi}d\phi\left|\frac{\widetilde{\mathrm{TDI}}(\omega)}{\widetilde{h}(\omega)}\right|^2. \tag*{(25)}

We call the corresponding quantity R\sqrt{R} the transfer function.

Substituting the six single-link responses gives the squared modulus inside the integral as

∣P1μ12(e−ik⃗⋅x⃗1−e−i(τ+k⃗⋅x⃗2))+P2μ23(e−ik⃗⋅x⃗2−e−i(τ+k⃗⋅x⃗3))+P3μ31(e−ik⃗⋅x⃗3−e−i(τ+k⃗⋅x⃗1))+P1′μ13(e−ik⃗⋅x⃗1−e−i(τ+k⃗⋅x⃗3))+P2′μ21(e−ik⃗⋅x⃗2−e−i(τ+k⃗⋅x⃗1))+P3′μ32(e−ik⃗⋅x⃗3−e−i(τ+k⃗⋅x⃗2))∣2,(26)\left|P_1\mu_{12}\left(e^{-i\vec{k}\cdot\vec{x}_1}-e^{-i(\tau+\vec{k}\cdot\vec{x}_2)}\right)+P_2\mu_{23}\left(e^{-i\vec{k}\cdot\vec{x}_2}-e^{-i(\tau+\vec{k}\cdot\vec{x}_3)}\right) +P_3\mu_{31}\left(e^{-i\vec{k}\cdot\vec{x}_3}-e^{-i(\tau+\vec{k}\cdot\vec{x}_1)}\right)+P_1'\mu_{13}\left(e^{-i\vec{k}\cdot\vec{x}_1}-e^{-i(\tau+\vec{k}\cdot\vec{x}_3)}\right) +P_2'\mu_{21}\left(e^{-i\vec{k}\cdot\vec{x}_2}-e^{-i(\tau+\vec{k}\cdot\vec{x}_1)}\right)+P_3'\mu_{32}\left(e^{-i\vec{k}\cdot\vec{x}_3}-e^{-i(\tau+\vec{k}\cdot\vec{x}_2)}\right)\right|^2, \tag*{(26)}

and rearranged into the form

RTDI(ω)=⟨∣A+B+C∣2⟩Ω,⟨⋅⟩Ω=14π∫dΩ(⋅).(27)R_{\mathrm{TDI}}(\omega)=\langle|A+B+C|^2\rangle_{\Omega},\qquad\langle\cdot\rangle_{\Omega}=\frac{1}{4\pi}\int d\Omega(\cdot). \tag*{(27)}

Here AA, BB, and CC are given by

A=μ12((P1+e−iτP2′)e−ik⃗⋅x⃗1−(P1e−iτ+P2′)e−ik⃗⋅x⃗2),B=μ23((P2+e−iτP3′)e−ik⃗⋅x⃗2−(P2e−iτ+P3′)e−ik⃗⋅x⃗3),C=μ31((P3+e−iτP1′)e−ik⃗⋅x⃗3−(P3e−iτ+P1′)e−ik⃗⋅x⃗1).(28)\begin{aligned} A&=\mu_{12}\left((P_1+e^{-i\tau}P_2')e^{-i\vec{k}\cdot\vec{x}_1}-(P_1e^{-i\tau}+P_2')e^{-i\vec{k}\cdot\vec{x}_2}\right),\\ B&=\mu_{23}\left((P_2+e^{-i\tau}P_3')e^{-i\vec{k}\cdot\vec{x}_2}-(P_2e^{-i\tau}+P_3')e^{-i\vec{k}\cdot\vec{x}_3}\right),\\ C&=\mu_{31}\left((P_3+e^{-i\tau}P_1')e^{-i\vec{k}\cdot\vec{x}_3}-(P_3e^{-i\tau}+P_1')e^{-i\vec{k}\cdot\vec{x}_1}\right). \tag*{(28)} \end{aligned}

For convenience we write out the expression for μ\mu

μ12=k^⋅n^12=sin⁡θcos⁡ϕcos⁡α+sin⁡θsin⁡ϕsin⁡α=sin⁡θcos⁡(ϕ−α),μ23=k^⋅n^23=sin⁡θcos⁡(ϕ+δ),μ31=k^⋅n^31=−sin⁡θcos⁡ϕcos⁡β+sin⁡θsin⁡ϕsin⁡β=−sin⁡θcos⁡(ϕ+β),(29)\begin{aligned} \mu_{12}&=\hat{k}\cdot\hat{n}_{12}=\sin\theta\cos\phi\cos\alpha+\sin\theta\sin\phi\sin\alpha=\sin\theta\cos(\phi-\alpha),\\ \mu_{23}&=\hat{k}\cdot\hat{n}_{23}=\sin\theta\cos(\phi+\delta),\\ \mu_{31}&=\hat{k}\cdot\hat{n}_{31}=-\sin\theta\cos\phi\cos\beta+\sin\theta\sin\phi\sin\beta=-\sin\theta\cos(\phi+\beta), \tag*{(29)} \end{aligned}
The two synthesized light paths of the equal-arm Michelson $X$ combination

Figure 2. The two synthesized light paths of the equal-arm Michelson XX combination. The labels show each one-way measurement and its delay relative to the final readout. SC1–SC3 denote the three spacecraft.

Here ui≡2πfLi/cu_i \equiv2\pi fL_i/c is the optical propagation phase of arm ii, with ui=uu_i = u in the equal-arm limit. The angle δ\delta satisfies tan⁡δ=(u2sin⁡β+u3sin⁡α)/(u2cos⁡β−u3cos⁡α)\tan\delta= (u_2\sin\beta+ u_3\sin\alpha)/(u_2\cos\beta- u_3\cos\alpha). The angular average can then be decomposed into six terms,

RTDI(ω)=⟨∣A∣2+∣B∣2+∣C∣2+2Re⁡[AB∗]+2Re⁡[AC∗]+2Re⁡[BC∗]⟩Ω.(30)R_{\mathrm{TDI}}(\omega) = \left\langle|A|^2 + |B|^2 + |C|^2 + 2\operatorname{Re}[AB^*] + 2\operatorname{Re}[AC^*] + 2\operatorname{Re}[BC^*] \right\rangle_{\Omega}. \tag*{(30)}

To express these angular integrals, we define the functions

f(ui)=2uicos⁡(ui)+(−2+ui2)sin⁡(ui)ui3,(31)f(u_i) = \frac{2u_i\cos(u_i) + (-2 + u_i^2)\sin(u_i)}{u_i^3}, \tag*{(31)}
g(ui)=uicos⁡(ui)+(−1+ui2)sin⁡(ui)ui3.g(u_i) = \frac{u_i\cos(u_i) + (-1 + u_i^2)\sin(u_i)}{u_i^3}.

The spatial-phase arguments of these integrals are vuivu_i, while the optical delay phases are uiu_i. The functions have removable limits f(0)=1/3f(0) = 1/3 and g(0)=2/3g(0) = 2/3, and high precision is used near these limits. The symbol Re denotes the real part and the asterisk denotes complex conjugation. The first three terms are the angular averages of the squared contributions from the individual arm pairs. Explicitly, we obtain:

⟨∣A∣2⟩Ω=13[(P1+e−iτP2)(P1∗+eiτP2∗)+(P1e−iτ+P2)(P1∗eiτ+P2∗)]−2f(vu3)Re⁡[(P1+e−iτP2)(P1∗eiτ+P2∗)].(32)\left\langle|A|^2 \right\rangle_{\Omega} = \frac{1}{3}\left[(P_1 + e^{-i\tau}P_2)(P_1^* + e^{i\tau}P_2^*) + (P_1e^{-i\tau} + P_2)(P_1^*e^{i\tau} + P_2^*)\right] - 2f(vu_3)\operatorname{Re}\left[(P_1 + e^{-i\tau}P_2)(P_1^*e^{i\tau} + P_2^*)\right]. \tag*{(32)}
⟨∣B∣2⟩Ω=13[(P2+e−iτP3′)(P2∗+eiτP3′∗)+(P2e−iτ+P3′)(P2∗eiτ+P3′∗)]−2f(vu1)Re⁡[(P2+e−iτP3′)(P2∗eiτ+P3′∗)].(33)\left\langle|B|^2 \right\rangle_{\Omega} = \frac{1}{3}\left[(P_2 + e^{-i\tau}P_3')(P_2^* + e^{i\tau}P_3'^*) + (P_2e^{-i\tau} + P_3')(P_2^*e^{i\tau} + P_3'^*)\right] - 2f(vu_1)\operatorname{Re}\left[(P_2 + e^{-i\tau}P_3')(P_2^*e^{i\tau} + P_3'^*)\right]. \tag*{(33)}
⟨∣C∣2⟩Ω=13[(P3+e−iτP1′)(P3∗+eiτP1′∗)+(P3e−iτ+P1′)(P3∗eiτ+P1′∗)]−2f(vu2)Re⁡[(P3+e−iτP1′)(P3∗eiτ+P1′∗)].(34)\left\langle|C|^2 \right\rangle_{\Omega} = \frac{1}{3}\left[(P_3 + e^{-i\tau}P_1')(P_3^* + e^{i\tau}P_1'^*) + (P_3e^{-i\tau} + P_1')(P_3^*e^{i\tau} + P_1'^*)\right] - 2f(vu_2)\operatorname{Re}\left[(P_3 + e^{-i\tau}P_1')(P_3^*e^{i\tau} + P_1'^*)\right]. \tag*{(34)}

The three squared terms have the same form under cyclic relabeling of the arms and their link coefficients. Each contains the powers of the two endpoint contributions and an interference term weighted by f(vui)f(vu_i) for arm ii. The remaining three terms describe interference between different arm pairs that survives direction averaging. These cross terms are given by

2Re⁡⟨AB∗⟩Ω=−13cos⁡(α+δ)[(P1e−iτ+P2′)(P2∗+eiτP3′∗)+(P1∗eiτ+P2∗)(P2+e−iτP3′)]+2cos⁡(α+δ)f(vu3)Re⁡[(P1+e−iτP2′)(P2∗+eiτP3′∗)]+[−2cos⁡(α+2β−δ)f(vu2)+2sin⁡(α+β)sin⁡(δ−β)g(vu2)]Re⁡[(P1+e−iτP2′)(P2∗eiτ+P3′∗)]+2cos⁡(α+δ)f(vu1)Re⁡[(P1e−iτ+P2′)(P2∗eiτ+P3′∗)].(35)\begin{aligned} 2\operatorname{Re}\left\langle AB^*\right\rangle_{\Omega} ={}&-\frac{1}{3}\cos(\alpha+\delta)\left[(P_1e^{-i\tau}+P_2')(P_2^*+e^{i\tau}P_3'^*)\right.\\ &\left.+(P_1^*e^{i\tau}+P_2^*)(P_2+e^{-i\tau}P_3')\right]\\ &+2\cos(\alpha+\delta)f(vu_3)\operatorname{Re}\left[(P_1+e^{-i\tau}P_2')(P_2^*+e^{i\tau}P_3'^*)\right]\\ &+\left[-2\cos(\alpha+2\beta-\delta)f(vu_2)\right.\\ &\left.+2\sin(\alpha+\beta)\sin(\delta-\beta)g(vu_2)\right]\operatorname{Re}\left[(P_1+e^{-i\tau}P_2')(P_2^*e^{i\tau}+P_3'^*)\right]\\ &+2\cos(\alpha+\delta)f(vu_1)\operatorname{Re}\left[(P_1e^{-i\tau}+P_2')(P_2^*e^{i\tau}+P_3'^*)\right]. \tag*{(35)} \end{aligned}
2Re⁡⟨BC∗⟩Ω=13cos⁡(δ−β)[(P2e−iτ+P3′)(P3∗+eiτP1∗)+(P2∗eiτ+P3∗)(P3+e−iτP1)]−2cos⁡(δ−β)f(vu1)Re⁡[(P2+e−iτP3′)(P3∗+eiτP1∗)]+[2cos⁡(2α+β+δ)f(vu3)+2sin⁡(α+δ)sin⁡(α+β)g(vu3)]Re⁡[(P2+e−iτP3′)(P3∗eiτ+P1∗)]−2cos⁡(δ−β)f(vu2)Re⁡[(P2e−iτ+P3′)(P3∗eiτ+P1∗)].(36)\begin{aligned} 2\operatorname{Re}\langle BC^*\rangle_{\Omega}={}&\frac{1}{3}\cos(\delta-\beta)\left[(P_2e^{-i\tau}+P_3')(P_3^*+e^{i\tau}P_1^*)\right.\\ &\left.+(P_2^*e^{i\tau}+P_3^*)(P_3+e^{-i\tau}P_1)\right]\\ &-2\cos(\delta-\beta)f(vu_1)\operatorname{Re}\left[(P_2+e^{-i\tau}P_3')(P_3^*+e^{i\tau}P_1^*)\right]\\ &+\left[2\cos(2\alpha+\beta+\delta)f(vu_3)\right.\\ &\left.+2\sin(\alpha+\delta)\sin(\alpha+\beta)g(vu_3)\right]\operatorname{Re}\left[(P_2+e^{-i\tau}P_3')(P_3^*e^{i\tau}+P_1^*)\right]\\ &-2\cos(\delta-\beta)f(vu_2)\operatorname{Re}\left[(P_2e^{-i\tau}+P_3')(P_3^*e^{i\tau}+P_1^*)\right]. \tag*{(36)} \end{aligned}
2Re⁡⟨AC∗⟩Ω=13cos⁡(α+β)[(P1+e−iτP2′)(P3∗eiτ+P1∗)+(P1∗+eiτP2∗)(P3e−iτ+P1′)]−2cos⁡(α+β)f(vu2)Re⁡[(P1+e−iτP2′)(P3∗+eiτP1∗)]+[2cos⁡(α−β+2δ)f(vu1)−2sin⁡(α+δ)sin⁡(β−δ)g(vu1)]Re⁡[(P1e−iτ+P2′)(P3∗+eiτP1∗)]−2cos⁡(α+β)f(vu3)Re⁡[(P1e−iτ+P2′)(P3∗eiτ+P1∗)].(37)\begin{aligned} 2\operatorname{Re}\langle AC^*\rangle_{\Omega}={}&\frac{1}{3}\cos(\alpha+\beta)\left[(P_1+e^{-i\tau}P_2')(P_3^*e^{i\tau}+P_1^*)\right.\\ &\left.+(P_1^*+e^{i\tau}P_2^*)(P_3e^{-i\tau}+P_1')\right]\\ &-2\cos(\alpha+\beta)f(vu_2)\operatorname{Re}\left[(P_1+e^{-i\tau}P_2')(P_3^*+e^{i\tau}P_1^*)\right]\\ &+\left[2\cos(\alpha-\beta+2\delta)f(vu_1)\right.\\ &\left.-2\sin(\alpha+\delta)\sin(\beta-\delta)g(vu_1)\right]\operatorname{Re}\left[(P_1e^{-i\tau}+P_2')(P_3^*+e^{i\tau}P_1^*)\right]\\ &-2\cos(\alpha+\beta)f(vu_3)\operatorname{Re}\left[(P_1e^{-i\tau}+P_2')(P_3^*e^{i\tau}+P_1^*)\right]. \tag*{(37)} \end{aligned}

The interference terms between different arm pairs can be positive or negative, depending on the geometry and the relative phases. Similar squared terms can therefore give different total responses.

For fixed detector geometry and field parameters, the same angular kernels apply to all the combinations considered here. Each combination supplies its own six delay coefficients, and their contributions sum to the direction-averaged power response in Eq. (30). Since all six terms are quadratic in these coefficients, a common factor q(D)q(D) scales the power response by ∣q(D)∣2|q(D)|^2. Section IV uses this property to compare the sensitivities of different combinations.

Numerical verification

To verify the analytic results derived above, we compare them with numerical angular integrals of the corresponding responses. As concrete examples, we use the optimal combinations A, E, and T formed from the Michelson combinations X, Y, and Z in an equal-arm, equilateral-triangle detector [17, 29, 30, 36]. In the time domain, these combinations are defined as follows:

A(t)=12[Z(t)−X(t)].(38)A(t)=\frac{1}{\sqrt{2}}[Z(t)-X(t)]. \tag*{(38)}
E(t)=16[X(t)−2Y(t)+Z(t)].(39)E(t)=\frac{1}{\sqrt{6}}[X(t)-2Y(t)+Z(t)]. \tag*{(39)}
T(t)=13[X(t)+Y(t)+Z(t)].(40)T(t)=\frac{1}{\sqrt{3}}[X(t)+Y(t)+Z(t)]. \tag*{(40)}

For A, E, and T, the six-link coefficients follow from the delay polynomials of X, Y, and Z. Their response functions are given below:

RA(ω)=(1−cos⁡2τ)[Q12+Q22].(41)R_A(\omega)=(1-\cos2\tau)[Q_1^2+Q_2^2]. \tag*{(41)}
RE(ω)=13(1−cos⁡2τ)[Q32+Q42].(42)R_E(\omega)=\frac{1}{3}(1-\cos2\tau)[Q_3^2+Q_4^2]. \tag*{(42)}
RT(ω)=643sin⁡4(τ2)sin⁡2τ[Q52+Q62].(43)R_T(\omega)=\frac{64}{3}\sin^4\left(\frac{\tau}{2}\right)\sin^2\tau[Q_5^2+Q_6^2]. \tag*{(43)}

The functions Q1Q_1 and Q2Q_2 correspond to the combination A:

Q1=−(μ32+μ12)[1+cos⁡(2τ)]+2μ32cos⁡(τ+k⃗⋅x⃗2+k⃗⋅x⃗3)+2μ12cos⁡(τ+k⃗⋅x⃗1+k⃗⋅x⃗2).(44)\begin{aligned} Q_1={}&-(\mu_{32}+\mu_{12})[1+\cos(2\tau)]\\ &+2\mu_{32}\cos(\tau+\vec{k}\cdot\vec{x}_2+\vec{k}\cdot\vec{x}_3)\\ &+2\mu_{12}\cos(\tau+\vec{k}\cdot\vec{x}_1+\vec{k}\cdot\vec{x}_2). \tag*{(44)} \end{aligned}
Q2=(μ32+μ12)sin⁡(2τ)−2μ32sin⁡(τ+k⃗⋅x⃗2+k⃗⋅x⃗3)−2μ12sin⁡(τ+k⃗⋅x⃗1+k⃗⋅x⃗2).(45)\begin{aligned} Q_2={}&(\mu_{32}+\mu_{12})\sin(2\tau)\\ &-2\mu_{32}\sin(\tau+\vec{k}\cdot\vec{x}_2+\vec{k}\cdot\vec{x}_3)\\ &-2\mu_{12}\sin(\tau+\vec{k}\cdot\vec{x}_1+\vec{k}\cdot\vec{x}_2). \tag*{(45)} \end{aligned}

The functions Q3Q_3 and Q4Q_4 correspond to the combination E:

Q3=−(2μ13+μ23−μ21)[1+cos⁡(2τ)]+4μ13cos⁡(τ+k⃗⋅x⃗1+k⃗⋅x⃗3)+2μ23cos⁡(τ+k⃗⋅x⃗2+k⃗⋅x⃗3)−2μ21cos⁡(τ+k⃗⋅x⃗1+k⃗⋅x⃗2).(46)\begin{aligned} Q_3={}&-(2\mu_{13}+\mu_{23}-\mu_{21})[1+\cos(2\tau)]\\ &+4\mu_{13}\cos(\tau+\vec{k}\cdot\vec{x}_1+\vec{k}\cdot\vec{x}_3)\\ &+2\mu_{23}\cos(\tau+\vec{k}\cdot\vec{x}_2+\vec{k}\cdot\vec{x}_3)\\ &-2\mu_{21}\cos(\tau+\vec{k}\cdot\vec{x}_1+\vec{k}\cdot\vec{x}_2). \tag*{(46)} \end{aligned}
Q4=(2μ13+μ23−μ21)sin⁡(2τ)−4μ13sin⁡(τ+k⃗⋅x⃗1+k⃗⋅x⃗3)−2μ23sin⁡(τ+k⃗⋅x⃗2+k⃗⋅x⃗3)+2μ21sin⁡(τ+k⃗⋅x⃗1+k⃗⋅x⃗2).(47)\begin{aligned} Q_4={}&(2\mu_{13}+\mu_{23}-\mu_{21})\sin(2\tau)\\ &-4\mu_{13}\sin(\tau+\vec{k}\cdot\vec{x}_1+\vec{k}\cdot\vec{x}_3)\\ &-2\mu_{23}\sin(\tau+\vec{k}\cdot\vec{x}_2+\vec{k}\cdot\vec{x}_3)\\ &+2\mu_{21}\sin(\tau+\vec{k}\cdot\vec{x}_1+\vec{k}\cdot\vec{x}_2). \tag*{(47)} \end{aligned}

The functions Q5Q_5 and Q6Q_6 correspond to the combination T:

Q5=μ13[1+cos⁡(k⃗⋅x⃗3)]+μ21[cos⁡(k⃗⋅x⃗2)+1]−μ23[cos⁡(k⃗⋅x⃗2)+cos⁡(k⃗⋅x⃗3)].(48)\begin{aligned} Q_5={}&\mu_{13}[1+\cos(\vec{k}\cdot\vec{x}_3)]\\ &+\mu_{21}[\cos(\vec{k}\cdot\vec{x}_2)+1]\\ &-\mu_{23}[\cos(\vec{k}\cdot\vec{x}_2)+\cos(\vec{k}\cdot\vec{x}_3)]. \tag*{(48)} \end{aligned}
Q6=μ13sin⁡(k⃗⋅x⃗3)+μ21sin⁡(k⃗⋅x⃗2)−μ23[sin⁡(k⃗⋅x⃗2)+sin⁡(k⃗⋅x⃗3)].(49)\begin{aligned} Q_6={}&\mu_{13}\sin(\vec{k}\cdot\vec{x}_3)\\ &+\mu_{21}\sin(\vec{k}\cdot\vec{x}_2)\\ &-\mu_{23}[\sin(\vec{k}\cdot\vec{x}_2)+\sin(\vec{k}\cdot\vec{x}_3)]. \tag*{(49)} \end{aligned}

Under the same equal-arm assumptions, we integrate the directional power responses given by Q1Q_1–Q6Q_6 numerically using 10510^5 isotropically sampled directions at frequencies from 10−510^{-5} to 1 Hz. We compare these integrals with the analytic results derived in section III B. To quantify this comparison, we report the relative amplitude deviation ϵR=RMC/Ran−1\epsilon_{\sqrt{R}}=\sqrt{R_{\mathrm{MC}}/R_{\mathrm{an}}}-1 and the normalized power deviation z=(RMC−Ran)/σMCz=(R_{\mathrm{MC}}-R_{\mathrm{an}})/\sigma_{\mathrm{MC}}. Here pjp_j is the unaveraged power response constructed from the auxiliary functions at the jjth independent isotropic sample. The Monte Carlo estimate and its standard error are

RMC=1M∑j=1Mpj,(50)R_{\mathrm{MC}}=\frac{1}{M}\sum_{j=1}^{M}p_j, \tag*{(50)}
σMC=[1M(M−1)∑j=1M(pj−RMC)2]1/2,\sigma_{\mathrm{MC}}=\left[\frac{1}{M(M-1)}\sum_{j=1}^{M}(p_j-R_{\mathrm{MC}})^2\right]^{1/2},

where M=105M=10^5. Thus σMC\sigma_{\mathrm{MC}} estimates the standard error of the Monte Carlo mean power response. In the error panels, σ\sigma instead denotes the standard error of 100ϵR100\epsilon_{\sqrt{R}} under first-order propagation evaluated at RanR_{\mathrm{an}}:

σ=100σMC2Ran.(51)\sigma=\frac{100\sigma_{\mathrm{MC}}}{2R_{\mathrm{an}}}. \tag*{(51)}

Here σ\sigma and 3σ3\sigma are expressed in percentage points and are distinct from σMC\sigma_{\mathrm{MC}}. Exact response zeros are excluded from relative-error statistics.

In the examined band and sampling configuration, the analytic responses agree well with the Monte Carlo angular integrals for A, E, and T. Their relative amplitude deviations are below approximately 0.3%, and every valid frequency satisfies ∣z∣≤3|z|\le3. This agreement confirms the correctness of the analytic angular averages for A, E, and T within the precision of the numerical comparison.

Figure 3–Figure 5 compare the numerical and analytic results. Table I summarizes this comparison, and the right panels show the corresponding relative amplitude deviations in percent with the pointwise ±3σ\pm3\sigma ranges defined in Eq. (51).

Combinationmax⁡∣ϵR∣\max|\epsilon_{\sqrt{R}}|max⁡∣z∣\max|z|
A0.2257%1.4796
E0.0564%0.3993
T0.2621%1.3779

Table I. Comparison of analytic responses with Monte Carlo angular integrals of the expressions in terms of the auxiliary functions.

Transfer function of the A combination and relative difference

Figure 3. Transfer function R\sqrt{R} of the A combination (left) and relative amplitude deviation ϵR\epsilon_{\sqrt{R}} between numerical and analytic results (right).

Transfer function of the T combination and relative difference

Figure 5. Transfer function R\sqrt{R} of the T combination (left) and relative amplitude deviation ϵR\epsilon_{\sqrt{R}} between numerical and analytic results (right).

Discussion

Following the numerical verification for A, E, and T, we compare the responses and sensitivities of the 12-link, 14-link, and 16-link TDI combinations under the same static equal-arm model [30]. We use their low-frequency behavior to classify the responses and explain how the sensitivities enter estimates of the scalar coupling.

For this comparison, let NO(f)N_O(f) be the noise power spectral density (PSD) of a combination OO. Its sensitivity curve is defined as

S(f)=NO(f)RO(f).(52)S(f)=\frac{N_O(f)}{R_O(f)}. \tag*{(52)}

where RO(f)R_O(f) is the power response given in this paper. Thus SS is an equivalent input PSD, and S\sqrt{S} is the amplitude sensitivity in Hz−1/2^{-1/2}. Once the laser noise is suppressed by TDI, two secondary noises limit detector performance: the optical metrology system noise, which dominates at high frequencies, and the test-mass acceleration noise, which dominates at low frequencies. We use LISA-like secondary-noise spectra [14, 17]. The optical metrology system (OMS) noise is given by:

SOMS(f)=(2πfcsOMS)2[1+(2×10−3 Hzf)4]1Hz.(53)S_{\mathrm{OMS}}(f)=\left(\frac{2\pi f}{c}s_{\mathrm{OMS}}\right)^2\left[1+\left(\frac{2\times10^{-3}\,\mathrm{Hz}}{f}\right)^4\right]\frac{1}{\mathrm{Hz}}. \tag*{(53)}

The test-mass acceleration (ACC) noise is given by:

Sacc(f)=(sACC2πfc)2[1+(0.4×10−3 Hzf)2]×[1+(f8×10−3 Hz)4]1Hz.(54)S_{\mathrm{acc}}(f)=\left(\frac{s_{\mathrm{ACC}}}{2\pi f c}\right)^2\left[1+\left(\frac{0.4\times10^{-3}\,\mathrm{Hz}}{f}\right)^2\right]\times\left[1+\left(\frac{f}{8\times10^{-3}\,\mathrm{Hz}}\right)^4\right]\frac{1}{\mathrm{Hz}}. \tag*{(54)}
Transfer function of the E combination and relative difference

Figure 4. Transfer function R\sqrt{R} of the E combination (left) and relative amplitude deviation ϵR\epsilon_{\sqrt{R}} between numerical and analytic results (right).

Assuming independent OMS and test-mass noise sources with identical spectra for all links and test masses, respectively, the six-link coefficients give the total noise PSD as [30]

NO(f)=[Soms(f)+2Sacc(f)]∑i=13(∣Pi∣2+∣Pi′∣2)+4Sacc(f)cos⁡u Re⁡[P1P2′∗+P2P3′∗+P3P1′∗].(55)N_{\mathrm{O}}(f)=\left[S_{\mathrm{oms}}(f)+2S_{\mathrm{acc}}(f)\right]\sum_{i=1}^{3}\left(\lvert P_i\rvert^2+\lvert P_{i'}\rvert^2\right)+4S_{\mathrm{acc}}(f)\cos u\,\operatorname{Re}\left[P_1P_{2'}^*+P_2P_{3'}^*+P_3P_{1'}^*\right]. \tag*{(55)}

Here the coefficients PiP_i and Pi′P_{i'} use the six-link order defined in section III B. The coefficients somss_{\mathrm{oms}} and saccs_{\mathrm{acc}} set the optical displacement and test-mass acceleration noise amplitudes, respectively. The benchmark uses L=3×109 mL=3\times10^9\ \mathrm{m}, c=3×108 m s−1c=3\times10^8\ \mathrm{m\,s^{-1}}, v=10−3v=10^{-3}, soms=15×10−12 ms_{\mathrm{oms}}=15\times10^{-12}\ \mathrm{m}, and sacc=3×10−15 m s−2s_{\mathrm{acc}}=3\times10^{-15}\ \mathrm{m\,s^{-2}}.

The sets of 12-link, 14-link, and 16-link combinations contain 3, 4, and 38 combinations, respectively. The 12-link set contains two ordinary combinations, [α]112[\alpha]_1^{12} and [α]212[\alpha]_2^{12}, and one ζ\zeta combination, [α]ζ12[\alpha]_\zeta^{12}. The 14-link ordinary combinations are [U]114[U]_1^{14}, [U]214[U]_2^{14}, and [EP]114[EP]_1^{14}; their responses and noise spectra coincide in the equal-arm limit. The remaining combination, [EP]214[EP]_2^{14}, is of ζ\zeta type. Among the 38 16-link combinations, six are of ζ\zeta type: [T]916[T]_9^{16}, [T]1216[T]_{12}^{16}, [T]1416[T]_{14}^{16}, [T]1516[T]_{15}^{16}, [T]1816[T]_{18}^{16}, and [T]1916[T]_{19}^{16}. The remaining 32 are ordinary combinations.

To interpret the low-frequency differences between these combinations, we expand their responses for u≪1u\ll1 and v≪1v\ll1. The leading terms are

Rn=An(415v2u6+19u8)+O(v2u8)+O(u10),(56)R_n=A_n\left(\frac{4}{15}v^2u^6+\frac{1}{9}u^8\right)+O(v^2u^8)+O(u^{10}), \tag*{(56)}
Rζ=k280v4u8+O(u10).R_\zeta=\frac{k}{280}v^4u^8+O(u^{10}).

Here AnA_n and kk are combination-dependent low-frequency coefficients. Ordinary combinations therefore have R∝v2f6R\propto v^2f^6 for u≪vu\ll v, and R∝f8R\propto f^8 for v≪u≪1v\ll u\ll1. Their transfer functions R\sqrt{R} scale as f3f^3 and f4f^4, respectively. The ζ\zeta response lacks both leading ordinary terms and is suppressed by v4v^4 in the displayed low-frequency expansion. It does not exhibit the same two-term crossover. For example, An=3A_n=3 for [α]212[\alpha]_2^{12} and An=9A_n=9 for [U]316[U]_3^{16}, while k=1k=1 for [α]312[\alpha]_3^{12} and k=4k=4 for [EP]214[EP]_2^{14}.

These expansions describe the low-frequency response, while the full response and noise spectra determine sensitivity across the band. Equal leading coefficients do not imply equal full response curves. Across all 45 combinations, the current equal-arm response and noise model gives 21 distinct power-response curves and 11 distinct single-channel amplitude-sensitivity curves. The latter are not 11 statistically independent channels. If two coefficient vectors satisfy Pb=q(D)Pa\mathbf{P}_b=q(D)\mathbf{P}_a, then Rb=∣q∣2RaR_b=\lvert q\rvert^2R_a and Nb=∣q∣2NaN_b=\lvert q\rvert^2N_a, so Sb=SaS_b=S_a wherever the ratio is defined. A common filter zero must be treated by a limiting expression, rather than by interpreting 0/00/0 as a sensitivity improvement or loss. For the 12-link ordinary pair, q=1+D+D2q=1+D+D^2; the larger low-frequency response of [α]112[\alpha]_1^{12} is accompanied by proportionally larger noise.

Program indexCombinationCoefficient
6[X]116[X]_1^{16}An=192A_n=192
2[U]416[U]_4^{16}An=147A_n=147
4[U]516[U]_5^{16}An=39A_n=39
20[T]716[T]_7^{16}An=75A_n=75
31[T]916[T]_9^{16}k=1k=1

caption: tbl:2. Five displayed 16-link representatives. Columns give the program index, the combination, and the low-frequency coefficient in Eq. (56). The program index refers to the enumeration used in the calculation files.

To illustrate these comparisons, we select five representative 16-link combinations, shown in Figure 8 and listed in table II. Four ordinary combinations illustrate the frequency-dependent balance between signal and noise, and one represents the suppressed ζ\zeta response. On the verified finite grid from 10−4 Hz10^{-4}\,\mathrm{Hz} to 0.1 Hz0.1\,\mathrm{Hz}, the amplitude-sensitivity envelope of the four ordinary representatives exceeds the full ordinary-channel optimum by at most approximately 3.09%.

Transfer functions and sensitivity curves for the 16-link combinations

Figure 8. Transfer functions and sensitivity curves for the 16-link combinations.

The two leading terms in the ordinary response in Eq. (56) also locate the transition between the low-frequency regimes. Equating them gives the critical frequency

fc≃c125vc2πL.(57)f_{\mathrm{c}}\simeq c\sqrt{\frac{12}{5}}\frac{v_{\mathrm{c}}}{2\pi L}. \tag*{(57)}

Here vc∼10−3c≃3×105 m s−1v_{\mathrm{c}}\sim10^{-3}c\simeq3\times10^5\,\mathrm{m\,s^{-1}} is the field velocity. For the benchmark, the critical frequency is 2.47×10−5 Hz2.47\times10^{-5}\,\mathrm{Hz}, within the plotting range. The lowest plotted frequency is not deep in the u≪vu\ll v regime. These power laws depend on the observable and its delay factors; they are not, by themselves, unique discriminators of scalar DM against gravitational-wave signals. Channel selection requires comparing N/RN/R: a larger response or a larger link count does not alone imply better sensitivity. A suppressed scalar response may support a consistency check, but it does not guarantee a pure-noise channel or smaller noise.

The equivalent input sensitivity can be converted into a scalar-coupling sensitivity for space-based detectors through the effective scalar coupling [17],

α(ϕ)≃dg∗≃dg+0.093(dm^−dg).(58)\alpha(\phi)\simeq d_g^*\simeq d_g+0.093(d_{\hat m}-d_g). \tag*{(58)}

We assume that the field constitutes the local DM density ρDM\rho_{\mathrm{DM}} and that the observation time TT is shorter than the field coherence time. With ϕκ=2ρDM/mϕ\phi_\kappa=\sqrt{2\rho_{\mathrm{DM}}}/m_\phi, the illustrative detectable-amplitude condition is

∣h~(mϕ)∣=mϕMsT=dg∗ϕκ∣k⃗∣mϕT=SO,(59)\lvert\tilde h(m_\phi)\rvert=m_\phi\mathcal{M}_s\sqrt{T}=d_g^*\phi_\kappa\frac{\lvert\vec{k}\rvert}{m_\phi}\sqrt{T}=\sqrt{S_{\mathrm{O}}}, \tag*{(59)}

and hence

dg∗=mϕκvDMSO2ρDMT.(60)d_g^*=\frac{m_\phi}{\kappa v_{\mathrm{DM}}}\sqrt{\frac{S_{\mathrm{O}}}{2\rho_{\mathrm{DM}}T}}. \tag*{(60)}
Transfer functions and sensitivity curves for the 12-link combinations

Figure 6. Transfer functions and sensitivity curves for the 12-link combinations.

Transfer functions and sensitivity curves for the 14-link combinations

Figure 7. Transfer functions and sensitivity curves for the 14-link combinations.

Here SO=NO/ROS_{\mathrm{O}} = N_{\mathrm{O}}/R_{\mathrm{O}}. In Eq. (59), h~\tilde{h} denotes the finite-time spectral amplitude h~T/T\tilde{h}_{T}/\sqrt{T}, using the observation window defined in section II. The magnitude of the field velocity is vDM≃∣k⃗∣/mϕ≃vv_{\mathrm{DM}} \simeq|\vec{k}|/m_{\phi} \simeq v. If d^m=0\hat{d}_{m} = 0, the quoted approximation gives dg∗≃0.907dgd_{g}^{*} \simeq0.907d_{g}. This relation illustrates how the analytic responses obtained here enter projected coupling estimates. Such an estimate requires a specified local-field model, noise spectrum, integration prescription, and detection threshold. We do not derive a new confidence-level exclusion curve in this paper. The range 10−5 Hz10^{-5}\,\mathrm{Hz}–1 Hz1\,\mathrm{Hz} corresponds to rest energies mϕc2≃4.14×10−20 eVm_{\phi}c^{2} \simeq4.14 \times10^{-20}\,\mathrm{eV}–4.14×10−15 eV4.14 \times10^{-15}\,\mathrm{eV}. Comparisons with fifth-force, equivalenceprinciple, or interferometric constraints require matching these assumptions [17, 23, 24, 34].

These response and sensitivity comparisons assume a static detector, a monochromatic plane wave, and a fixed field velocity v\mathbf{v}, and do not take spacecraft motion or orbital modulation into account. The equal-arm calculation is a baseline approximation. Although actual arm-length variations may be relatively small, their effect depends on frequency, required accuracy, and the observable. Near response zeros and in suppressed channels, relative changes can be large even for small arm variations. Time-dependent unequal arms also require a suitable TDI delay construction to maintain laser-noise cancellation; this requirement is distinct from the accuracy of the equal arm scalar-response approximation. The impact of these approximations on the sensitivity estimate can be quantified term by term in future work using the specific mission orbits.

Conclusions

For ultralight scalar-field dark matter we have derived analytic expressions for the response functions of space-based gravitational-wave detectors to different TDI combinations in a static model, with the explicit comparisons performed in the equal-arm limit. We established a derivation chain from the scalar-field coupling action, through the test-mass displacement and the single-link Doppler response, to the response of a TDI combination. We give the general form of the response function for an arbitrary combination. For A, E, and T, numerical integration of the directional responses confirms the analytic angular averages within the precision of the comparison. These analytic expressions can be used to compare the response characteristics of different combinations and compute their sensitivity curves. The 45 geometric combinations are separated into ordinary and ζ\zeta types. The ordinary responses exhibit two low-frequency regimes, and the adopted noise model gives 11 distinct single-channel amplitude-sensitivity curves. Common signal and noise filtering explains why different responses can give the same S=N/RS=N/R. Similar response functions have also been used to constrain scalar couplings with space-based gravitational-wave detectors [17]. Confidence-level limits require separate statistical analysis. The above conclusions rest on the equal-arm, static-detector, and single-plane-wave assumptions. For more general orbital configurations and second-generation TDI, the response functions must be extended accordingly.

Acknowledgments

This work was supported by the National Key R&D Program of China under Grant No. 2024YFC2207500 and the National Natural Science Foundation of China under Grant No. 12405060.

Data availability

No new observational or experimental data were generated in this study.

References

References

  1. [1]V. C. Rubin and W. K. Ford, Jr., Rotation of the Andromeda Nebula from a Spectroscopic Survey of Emission Regions, Astrophys. J. 159 (1970) 379–403.DOI
  2. [2]N. Aghanim, Y. Akrami, M. Ashdown, et al., Planck 2018 results. VI. Cosmological parameters, Astron. Astrophys. 641 (2020) A6.
  3. [3]E. Aprile, K. Abe, F. Agostini, et al., First Dark Matter Search with Nuclear Recoils from the XENONnT Experiment, Phys. Rev. Lett. 131 (2023) 041003.
  4. [4]J. Aalbers, D. S. Akerib, C. W. Akerlof, et al., First Dark Matter Search Results from the LUX-ZEPLIN (LZ) Experiment, Phys. Rev. Lett. 131 (2023) 041002.DOI
  5. [5]Y. Meng, Z. Wang, Y. Tao, et al., Dark Matter Search Results from the PandaX-4T Commissioning Run, Phys. Rev. Lett. 127 (2021) 261802.DOI
  6. [6]M. Ackermann, A. Albert, B. Anderson, et al., Searching for Dark Matter Annihilation from Milky Way Dwarf Spheroidal Galaxies with Six Years of Fermi Large Area Telescope Data, Phys. Rev. Lett. 115 (2015) 231301.DOI
  7. [7]D. J. E. Marsh, Axion cosmology, Phys. Rep. 643 (2016) 1–79.DOI
  8. [8]L. Hui, J. P. Ostriker, S. Tremaine, et al., Ultralight scalars as cosmological dark matter, Phys. Rev. D 95 (2017) 043541.DOI
  9. [9]L. Hui, Wave Dark Matter, Annu. Rev. Astron. Astrophys. 59 (2021) 247–289.
  10. [10]E. G. M. Ferreira, Ultra-light dark matter, Astron. Astrophys. Rev. 29 (2021) 7.DOI
  11. [11]F. Piazza and M. Pospelov, Sub-eV scalar dark matter through the super-renormalizable Higgs portal, Phys. Rev. D 82 (2010) 043533.DOI
  12. [12]P. W. Graham, D. E. Kaplan, J. Mardon, et al., Dark matter direct detection with accelerometers, Phys. Rev. D 93 (2016) 075029.DOI
  13. [13]S. Morisaki and T. Suyama, Detectability of ultralight scalar field dark matter with gravitational-wave detectors, Phys. Rev. D 100 (2019) 123512.
  14. [14]P. Amaro-Seoane, H. Audley, S. Babak, et al., Laser Interferometer Space Antenna, arXiv:1702.00786 [astro-ph.IM].
  15. [15]J. Luo, L. S. Chen, H. Z. Duan, et al., TianQin: a space-borne gravitational wave detector, Class. Quantum Grav. 33 (2016) 035010.DOI
  16. [16]W. R. Hu and Y. L. Wu, The Taiji Program in Space for gravitational wave physics and the nature of gravity, Natl. Sci. Rev. 4 (2017) 685–686.DOI
  17. [17]J. C. Yu, Y. H. Yao, Y. Tang, et al., Sensitivity of space-based gravitational-wave interferometers to ultra- light bosonic fields and dark matter, Phys. Rev. D 108 (2023) 083007.
  18. [18]A. Pierce, K. Riles, and Y. Zhao, Searching for Dark Photon Dark Matter with Gravitational-Wave Detectors, Phys. Rev. Lett. 121 (2018) 061102.DOI
  19. [19]H. Grote and Y. V. Stadnik, Novel signatures of dark matter in laser-interferometric gravitational-wave detectors, Phys. Rev. Res. 1 (2019) 033187.DOI
  20. [20]Y. Michimura, T. Fujita, S. Morisaki, et al., Ultralight vector dark matter search with auxiliary length channels of gravitational wave detectors, Phys. Rev. D 102 (2020) 102001.DOI
  21. [21]S. Morisaki, T. Fujita, Y. Michimura, et al., Improved sensitivity of interferometric gravitational-wave detectors to ultralight vector dark matter from the finite light-traveling time, Phys. Rev. D 103 (2021) L051702.DOI
  22. [22]G. P. Centers, J. W. Blanchard, J. Conrad, et al., Stochastic fluctuations of bosonic dark matter, Nat. Commun. 12 (2021) 7321.DOI
  23. [23]A. L. Miller and L. Mendes, First search for ultralight dark matter with a space-based gravitational-wave antenna: LISA Pathfinder, Phys. Rev. D 107 (2023) 063015.DOI
  24. [24]K. Fukusumi, S. Morisaki, and T. Suyama, Upper limit on scalar field dark matter from LIGO-Virgo third observation run, Phys. Rev. D 108 (2023) 095054.arxiv.org/abs/2303.13088
  25. [25]H. Kim, Gravitational interaction of ultralight dark matter with interferometers, J. Cosmol. Astropart. Phys. 12 (2023) 018.arxiv.org/abs/2306.13348
  26. [26]M. Tinto and J. W. Armstrong, Cancellation of laser noise in an unequal-arm interferometer detector of gravitational radiation, Phys. Rev. D 59 (1999) 102003.DOI
  27. [27]J. W. Armstrong, F. B. Estabrook, and M. Tinto, Time-Delay Interferometry for Space-based Gravitational Wave Searches, Astrophys. J. 527 (1999) 814–826.DOI
  28. [28]F. B. Estabrook, M. Tinto, and J. W. Armstrong, Time-delay analysis of LISA gravitational wave data: Elimination of spacecraft motion effects, Phys. Rev. D 62 (2000) 042002.DOI
  29. [29]M. Tinto and S. V. Dhurandhar, Time-delay interferometry, Living Rev. Relativ. 24 (2021) 1.
  30. [30]P. P. Wang, W. L. Qian, Z. Q. Wu, et al., Sensitivity functions for geometric time-delay interferometry combinations, Phys. Rev. D 108 (2023) 044075.DOI
  31. [31]M. Kawasaki and K. Nakayama, Axions: Theory and Cosmological Role, Annu. Rev. Nucl. Part. Sci. 63 (2013) 69–95.DOI
  32. [32]T. Damour and J. F. Donoghue, Equivalence principle violations and couplings of a light dilaton, Phys. Rev. D 82 (2010) 084033.DOI
  33. [33]C. M. Will, The Confrontation between General Relativity and Experiment, Living Rev. Relativ. 17 (2014) 4.
  34. [34]P. Touboul, G. Métris, M. Rodrigues, et al., MICROSCOPE Mission: Final Results of the Test of the Equivalence Principle, Phys. Rev. Lett. 129 (2022) 121102.DOI
  35. [35]F. B. Estabrook and H. D. Wahlquist, Response of Doppler spacecraft tracking to gravitational radiation, Gen. Relativ. Gravit. 6 (1975) 439–447.DOI
  36. [36]T. A. Prince, M. Tinto, S. L. Larson, et al., LISA optimal sensitivity, Phys. Rev. D 66 (2002) 122002.DOI

Paper details

vlnc:W_rd6fq2u7
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 0

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…