betaFeedback

WorksPhysics and Astronomy

Challenging Spontaneous Quantum Collapse with XENONnT

Abstract

We report on the search for X-ray radiation as predicted from dynamical quantum collapse with low-energy electronic recoil data in the energy range of 1-140 keV from the first science run of the XENONnT dark matter detector. Spontaneous radiation is an unavoidable effect of dynamical collapse models, which were introduced as a possible solution to the long-standing measurement problem in quantum mechanics. The analysis utilizes a model that for the first time accounts for cancellation effects in the emitted spectrum, which arise in the X-ray range due to the opposing electron-proton charges in xenon atoms. New world-leading limits on the free parameters of the Markovian continuous spontaneous localization and Diósi-Penrose models are set, improving previous best constraints by two orders of magnitude and a factor of five, respectively. The original values proposed for the strength and the correlation length of the continuous spontaneous localization model are excluded experimentally for the first time.

(XENON Collaboration) One of the greatest mysteries of quantum mechanics is how classical behavior emerges from the quantum realm. The superposition principle has been experimentally verified at the microscopic level with extreme precision [1], but superpositions of macroscopic states are not observed. Moreover, the mechanism that triggers the quantum-to-classical transition is not encoded in quantum mechanics. This measurement problem has led to the development of consistent phenomenological theories that account for the progressive breakdown of quantum superpositions as the size and complexity of a system increase. Dynamical Collapse Models (DCMs) consist in non-linear and stochastic modifications of the Schrödinger equation, which require the introduction of phenomenological parameters, in such a way that the collapse rate results to be extremely small for microscopic objects, but an amplification mechanism ensures localization at the macroscopic level. The modified dynamics result in a Brownian-like diffusion of quantum systems in space during which charged particles emit spontaneous electromagnetic radiation. DCMs have been tested using interferometry [2, 3], by measuring the heating of astrophysical objects [4] and by trying to detect indirect effects of collapse dynamics using systems such as cold atoms [5], optomechanical devices [6, 7], phonon excitations in crystals [8], and gravitational wave detectors [9, 10, 11, 12]. Moreover, searches for spontaneous radiation in the form of X-rays or γ\gamma-rays have been carried out with germanium detectors [13, 14, 15]. In this Letter, we report on the search for spontaneous radiation emission by xenon atoms with the XENONnT dark matter detector, as predicted by two benchmark DCM models: the continuous spontaneous localization (CSL) [16, 17] and Diósi-Penrose (DP) [18, 19, 20] models. The two models share a similar structure for the dynamical equation. In the Markovian formulation, which is investigated in this work, a white stochastic noise is assumed in time. The models are characterized by a collapse rate parameter which sets the strength of the collapse, and a correlation length which measures the spatial resolution of the collapse, setting the scale beyond which spatial superpositions are suppressed. The key distinction between the two models lies in their spatial correlation forms: for CSL, it is Gaussian, with an amplitude determined by the collapse strength λ\lambda and a resolution scale set by rCr_{\mathrm{C}}. Ghirardi, Rimini, and Weber (GRW) [21] proposed values on the order of magnitude λGRW≃10−16 s−1\lambda^{\mathrm{GRW}} \simeq10^{-16}\ \mathrm{s}^{-1} and rCGRW≃10−7 mr_{\mathrm{C}}^{\mathrm{GRW}} \simeq10^{-7}\ \mathrm{m}, which ensure the effective collapse of macroscopic systems.

The collapse in the DP model is linked to gravity, and the spatial correlation is proportional to the Newtonian potential. The correlation length R0R_0 acts as a spatial cutoff parameter to avoid a divergence in the collapse rate for point-like particles, while the strength is given by the gravitational constant GG. Theoretical upper bounds on R0R_0 can be set by requiring the prevention of macroscopic quantum superpositions [22] before they can be perceived. This sets the collapse timescale governed by R0R_0 at ≲0.01 s\lesssim0.01\ \mathrm{s}, the approximate time resolution of the human eye. For the model systems investigated in [22], the limits depend strongly on their size LL: R0≲103 A˚R_0 \lesssim10^3\ \text{\AA} for L∼1 μmL \sim1\ \mu\mathrm{m} and R0≲5×106 A˚R_0 \lesssim5 \times10^6\ \text{\AA} for L∼10 μmL \sim10\ \mu\mathrm{m}. Spontaneous radiation searches provide the strongest experimental bounds on the model parameters R0R_0 of DP, as well as on the λ\lambda and rCr_{\mathrm{C}} of CSL over a broad range of the parameter space [13, 14, 15]. At sufficiently high energies of O(100 keV−MeV)O(100\ \mathrm{keV}-\mathrm{MeV}), the spontaneous radiation wavelengths λγ\lambda_\gamma are intermediate between the nuclear and atomic length scales. With good approximation, protons would emit radiation coherently, while electrons would emit incoherently [15], leading to

dΓCSL,DPdE∣t∝E−1(Np2+Ne),(1)\left.\frac{\mathrm{d}\Gamma^{\mathrm{CSL,DP}}}{\mathrm{d}E}\right|_{\mathrm{t}} \propto E^{-1}\left(N_{\mathrm{p}}^{2}+N_{\mathrm{e}}\right), \tag*{(1)}

for the rate of the spontaneous radiation. Here, NpN_{\mathrm{p}} and NeN_{\mathrm{e}} are the numbers of protons and electrons in the atom while EE is the photon energy for the radiation emitted. The constant of proportionality depends on the respective model parameters. Strong constraints on collapse models in the X-ray regime (19–100 keV) were previously set in Ref. [13], where the spontaneous emission from germanium atoms of the target was modeled according to the high-energy approximation as per Eq. (1). However, the phenomenology of spontaneous radiation is more complex when X-rays are considered, with λγ\lambda_\gamma of the order of the atomic orbit dimensions. Here, coherent emission by the electrons and cancellation effects between the oppositely charged electrons and protons must be considered. The generalization of the emission rates for energies as low as 1 keV was derived in Ref. [23]. We use these results to search for spontaneous radiation emission signals in the energy range of 1–140 keV. The implementation of the theoretical framework for this analysis is described in the supplemental material [24].

Due to their low background, low energy threshold of ∼1\sim1 keV [25], and target mass of several tonnes, contemporary dual-phase xenon time projection chambers (TPCs) promise high sensitivities to spontaneous radiation, by using liquid xenon (LXe) both as emitter and detection medium. In these detectors, energy deposited from interactions with the xenon target atoms gives rise to prompt scintillation light and free ionization electrons. The former is directly detected as so-called S1 signal by arrays of photomultiplier tubes (PMTs) at the top and bottom of the TPC. The liberated charge is converted into a likewise detectable secondary scintillation signal (S2). For this, an electric field between a cathode and gate electrode drifts the electrons toward the top of the TPC. There, a second, stronger electric field between the gate and an anode extracts and accelerates them into the gaseous phase, resulting in electroluminescence. Pairing both signals enables the reconstruction of the deposited energy and the interaction position. The combined energy scale EE is computed from the corrected scintillation signals (cS1cS1, cS2cS2) as E=W(cS1/g1+cS2/g2)E=W(cS1/g_1+cS2/g_2), where the mean energy to produce a quantum W=13.7 eV/quantaW=13.7\,\mathrm{eV/quanta} [26], and the detector-specific gain constants g1g_1 and g2g_2 are considered [27].

In general, the charge-to-light ratio is larger for particle interactions with the electrons as opposed to the nucleus of the xenon atom. This enables discrimination between electronic recoil (ER) and nuclear recoil (NR) interactions [28], with the former being expected for the X-ray signatures investigated in this Letter.

The XENONnT experiment [29] features a dual-phase TPC with a sensitive LXe mass of 5.9 t, monitored by a total of 494 Hamamatsu R11410-21 PMTs [30]. It offers an unprecedentedly low ER background of (15.8±1.3)(15.8\pm1.3) events/(t×\timesy×\timeskeV) below recoil energies of 30 keV in its first science run [25]. To suppress cosmogenic backgrounds, this experiment is located at the INFN Laboratori Nazionali del Gran Sasso (LNGS) in Italy, with a rock overburden providing shielding equivalent to about 3600 meters of water. Further background reduction is achieved through active tagging using a water tank surrounding the TPC, which is instrumented as a muon veto [31] and supplemented by an inner neutron veto system [32]. Moreover, an extensive radioassay campaign for the installed detector materials was performed [33] and the xenon in the detector is continuously purified from chemical and radioactive impurities [34, 35, 36].

With a few exceptions detailed below, the search for the spontaneous radiation signatures in ER data from XENONnT follows the analysis performed in Ref. [25]. The signal reconstruction, calibration, and event selection are further detailed in Ref. [27]. Data from the first XENONnT science run (SR0), collected from July 6, 2021, to November 10, 2021, with an exposure of 1.16 t×\timesy inside the (4.37±0.14)(4.37\pm0.14) t fiducial mass, is employed.

The expected signal spectra are modeled from the theoretical shapes according to Ref. [23]. Details on the signal models can be found in the supplemental material [24]. The detector response is modeled by a skew-Gaussian energy resolution smearing and the application of the combined efficiency of detection and event selection [25] to the signal spectra. Compared to [25], there are two differences in the efficiency modeling: First, work considers an acceptance loss from a data-selection against accidental pairings of isolated light and charge signals that was underestimated previously. Second, the event-building efficiency, determined analogously to Ref. [37] and projected to energy space, is considered. These efficiency adjustments influence the CSL [DP] model results in the following by ∼\sim17% [∼\sim6%].

A total of nine components are considered in the background model. These encompass the double-beta decay of 136^{136}Xe, the beta decays of 214^{214}Pb, 133^{133}Xe, and 85^{85}Kr, the double-electron capture of 124^{124}Xe, and the decay of 83m^{83\mathrm{m}}Kr via internal conversion inside the LXe target. Other backgrounds are gamma rays from detector construction materials, solar neutrinos scattering off electrons, and random pairings of uncorrelated S1 and S2s, referred to as accidental coincidences (ACs). Analogously to Ref. [38], the free electron approximation in the solar neutrino spectrum used in Ref. [25] is supplemented by a stepping approximation [39], accounting for the electron binding energies. Furthermore, the relative 85Kr{}^{85}\mathrm{Kr} rate uncertainty, which was previously overestimated due to an erroneous unit in the uncertainty propagation, was reduced from ∼65 %\sim65\ \% to ∼22 %\sim22\ \%. The impact of the adjustments to the background model compared to Ref. [25] on the results obtained in the following is <1 %<1\ \% for the CSL and DP models.

The fit of the combined signal and background model (H1H_1) to the measured data is performed in the parameter space of reconstructed energy in the range of 1–140 keV employing an unbinned maximum likelihood analogous to Refs. [25, 41]. The best-fit result for the Markovian CSL model is shown in Figure 1. The low-energy part of the signal region contains the highest rates and distinguishing features of the spontaneous emission spectra (see supplemental material [24]). This allows us to place stringent limits on the respective model parameters using a log-likelihood ratio test statistic and assuming asymptoticity of the likelihood [42].

Best-fit spectrum for the combined CSL signal and background model

Figure 1. Best-fit spectrum for the combined CSL signal and background model (H1H_1) to the XENONnT SR0 low-energy electronic recoil data. The individual background components are indicated by dashed lines, except for the subdominant AC background spectrum which is out of range and, therefore, not shown. The best-fit result for the DP model is practically identical (see also Figure S-1). The model discontinuity around 10 keV is due to the blinding of the dark matter search region for [40] which marginally reduces the ER rate in the data from [25] at the lowest energies.

For the Markovian CSL model, λ/rC2\lambda/r_{\mathrm{C}}^{2} does not change the spectral shape, so it can be deduced directly from the obtained fit rate multiplier when assuming a fixed initial value for λ/rC2\lambda/r_{\mathrm{C}}^{2}. The CSL best-fit result is shown in Figure 1, with a signal rate of 50−50+20050^{+200}_{-50} events/(t ×\times y) and a pp-value of ∼0.3\sim0.3. As a local discovery significance of 0.3 σ0.3\,\sigma is obtained, no significant excess is found and an upper limit of λ/rC2<3.0×10−3 s−1m−2\lambda/r_{\mathrm{C}}^{2}<3.0\times10^{-3}\ \mathrm{s}^{-1}\mathrm{m}^{-2} [3.7×10−3 s−1m−23.7\times10^{-3}\ \mathrm{s}^{-1}\mathrm{m}^{-2}] at 90 % confidence level (C.L.) [95 % C.L.] is derived. This constitutes an improvement over the previous best limit from the Majorana Demonstrator [13] by a factor of ∼135\sim135 and sets the new most stringent experimental constraint for rC≲10−5 mr_{\mathrm{C}}\lesssim10^{-5}\ \mathrm{m}. A comparison of these limits with constraints from other experiments and theoretical considerations is given in Figure 2. According to the log-likelihood ratio test statistic, the parameter set (rCGRW=1×10−7 mr_{\mathrm{C}}^{\mathrm{GRW}}=1\times10^{-7}\ \mathrm{m}, λGRW=1×10−16 s−1\lambda^{\mathrm{GRW}}=1\times10^{-16}\ \mathrm{s}^{-1}) deviates from the best-fit result by 9.1 σ9.1\,\sigma. For the first time, this allows to experimentally exclude CSL model parameter values in the range originally proposed by GRW.

XENONnT 95 % C.L. upper bound on the CSL model parameters

Figure 2. XENONnT 95 % C.L. upper bound on the CSL model parameters, compared to exclusion limits from other non-interferometric experiments and theoretical propositions, with the shaded areas marking the excluded regions of the parameter space. Results from the LISA Pathfinder gravitational wave detector [11, 12], microcantilever measurements [6], cold atoms experiments [5], and estimates from the bulk heating rate in the CUORE experiment [43] are given. The two previous best limits from X-ray emission searches by Donadi et al. [15] and the Majorana Demonstrator [13] are shown as well. Moreover, astrophysical bounds from lunar thermal emission as well as from the cooling of white dwarf J1251+4403 are indicated [4]. A commonly adopted lower theoretical bound can be introduced by requiring a maximum collapse time of ∼10 ms\sim10\ \mathrm{ms}, i.e., the perception time of the human eye, for a superposition of a single-layered graphene disk of a barely visible radius of ∼10 μm\sim10\ \mathrm{\mu m} [44]. The black markers indicate theoretical suggestions by Adler [45] and Ghirardi, Rimini, and Weber [46].

Due to the more complex rate dependencies on the free parameter R0R_0 in the DP model, which can result in changes of the spectral shape beyond a global scaling, the fitting method employing a single linear rate multiplier requires an iterative approach for the DP model: A fixed starting value for R0R_0 and, thus, a static spectral shape are assumed. The values assumed in the next iterations are then obtained from the best-fit rate multiplier of the previous iteration by considering only a scaling by the leading term proportional to R0−3R_0^{-3} (see Ref. [23]). Any starting values that are not excluded by former experiments lead to the convergence to a best-fit value of R0≈9.1×10−10 mR_0 \approx9.1 \times10^{-10}\,\mathrm{m}. Around this value, the spectral shape of the signal does not change significantly (see Figure S-1 in supplemental material [24]), such that best-fit values, significances, and limits are in good approximation independent of the assumed R0R_0. With a local DP discovery significance of 0.2 σ0.2\,\sigma, a lower limit of R0>4.9×10−10 mR_0 > 4.9 \times10^{-10}\,\mathrm{m} [4.5×10−10 m4.5 \times10^{-10}\,\mathrm{m}] at 90% C.L. [95% C.L.] is set. This constitutes an improvement by approximately a factor of five compared to the previous world-leading limit by the Majorana Demonstrator [13].

In summary, new best constraints on the CSL and DP model, respectively, of λ/rC2<3.0×10−3 s−1m−2\lambda/r_{\mathrm{C}}^2 < 3.0 \times10^{-3}\,\mathrm{s}^{-1}\mathrm{m}^{-2} [3.7×10−3 s−1m−23.7 \times10^{-3}\,\mathrm{s}^{-1}\mathrm{m}^{-2}] and R0>4.9×10−10 mR_0 > 4.9 \times10^{-10}\,\mathrm{m} [4.5×10−10 m4.5 \times10^{-10}\,\mathrm{m}] at 90% C.L. [95% C.L.] are set. The former allows for the first-time exclusion of the commonly assumed values (rCGRW,λGRW)(r_{\mathrm{C}}^{\mathrm{GRW}}, \lambda^{\mathrm{GRW}}) for a white noise field. The limit enhancements demonstrate the broad physics reach of the XENONnT experiment and dual-phase xenon TPCs in general. They further drive the ongoing exploration of the still feasible parameter space for the most well-studied dynamical collapse models. A wider parameter range remains to be probed for colored or dissipative model extensions [44, 47]. With more XENONnT data already available, further sensitivity enhancements are expected.

We gratefully acknowledge support from the National Science Foundation, Swiss National Science Foundation, German Ministry for Education and Research, Max Planck Gesellschaft, Deutsche Forschungsgemeinschaft, Helmholtz Association, Dutch Research Council (NWO), Fundacao para a Ciencia e Tecnologia, Weizmann Institute of Science, Binational Science Foundation, Région des Pays de la Loire, Knut and Alice Wallenberg Foundation, Kavli Foundation, JSPS Kakenhi, JST FOREST Program, and ERAN in Japan, Tsinghua University Initiative Scientific Research Program, UZH Postdoc Grant (Grant No. FK-24-101), DIM-ACAV+ Région Ile-de-France, and Istituto Nazionale di Fisica Nucleare. This project has received funding/support from the European Union’s Horizon 2020 research and innovation program under the Marie Sklodowska-Curie grant agreement No 860881-HIDDeN. C. C., K. P. and S. M. acknowledge of the John Templeton Foundation, Grant 62099. The opinions expressed in this publication are those of the authors and do not necessarily reflect the views of the John Templeton Foundation. C. C. acknowledge support from the Foundational Questions Institute and Fetzer Franklin Fund, a donor advised fund of Silicon Valley Community Foundation (Grants No. FQXi-RFP-CPW-2008 and FQXi-MGB-2011), and from the INFN (VIP). C. C. benefited from the EU COST Actions CA23115 and CA23130. K. P. acknowledge support from the Centro Ricerche Enrico Fermi - Museo Storico della Fisica e Centro Studi e Ricerche “Enrico Fermi” (Open Problems in Quantum Mechanics project).

We gratefully acknowledge support for providing computing and data-processing resources of the Open Science Pool and the European Grid Initiative, at the following computing centers: the CNRS/IN2P3 (Lyon - France), the Dutch national e-infrastructure with the support of SURF Cooperative, the Nikhef Data-Processing Facility (Amsterdam - Netherlands), the INFN-CNAF (Bologna - Italy), the San Diego Supercomputer Center (San Diego - USA) and the Enrico Fermi Institute (Chicago - USA). We acknowledge the support of the Research Computing Center (RCC) at The University of Chicago for providing computing resources for data analysis.

We thank the INFN Laboratori Nazionali del Gran Sasso for hosting and supporting the XENON project.

References

Supplemental Material

The low-energy generalization of the spontaneous radiation emission rates for the CSL and DP models used in this work was derived in Ref. [23]. The expression for the expected DP emission rate can be found in Ref. [23]. It follows the Diòsi [18, 19] as opposed to the Penrose [20] convention, which differ by a scaling factor of 8π8\pi. The expression for the Markovian CSL emission rate was simplified to

dΓdE∣tCSL=ℏe2λ4π2ε0c3m02rC2E{Np2+Ne+2⋅∑o,o′ pairsNoNo′⋅sinc⁡(β∣ρo−ρo′∣Eℏc)−2Np⋅∑oNo⋅sinc⁡(ρoEℏc)+∑oNo(No−1)⋅sinc⁡(αρoEℏc)}.(2)\left.\frac{\mathrm{d}\Gamma}{\mathrm{d}E}\right|_{\mathrm{t}}^{\mathrm{CSL}} = \frac{\hbar e^{2}\lambda}{4\pi^{2}\varepsilon_{0}c^{3}m_{0}^{2}r_{\mathrm{C}}^{2}E}\left\{N_{\mathrm{p}}^{2}+N_{\mathrm{e}}+2\cdot\sum_{o,o'\ \mathrm{pairs}}N_{o}N_{o'}\cdot\operatorname{sinc}\left(\frac{\beta\lvert\rho_{o}-\rho_{o'}\rvert E}{\hbar c}\right)-2N_{\mathrm{p}}\cdot\sum_{o}N_{o}\cdot\operatorname{sinc}\left(\frac{\rho_{o}E}{\hbar c}\right)+\sum_{o}N_{o}(N_{o}-1)\cdot\operatorname{sinc}\left(\frac{\alpha\rho_{o}E}{\hbar c}\right)\right\}. \tag*{(2)}
Spontaneous radiation rate spectrum

Figure S-1. Spontaneous radiation rate spectrum (black) from xenon atoms for a Markovian CSL model according to Equation (2), assuming the model parameter values proposed by Ghirardi, Rimini, and Weber [46]. The CSL best-fit spectrum is indicated as dark blue dashed line. The Markovian DP model spectra from Ref. [23] with the best-fit value and 95 % C.L. upper limit of R0R_0 are shown in light blue and red, respectively.

with sinc⁡(x)=sin⁡(x)/x\operatorname{sinc}(x)=\sin(x)/x for x>0x>0. The simplification follows from the scale parameter rC≳1.15×10−8 mr_{\mathrm{C}}\gtrsim1.15\times10^{-8}\,\mathrm{m} significantly exceeding the mutual distances between all charges in the atomic system [15, 44]. In Equation (2) the distances between electron pairs are parameterized in terms of atomic orbit mean radii (ρo\rho_o) using the constants α\alpha and β\beta. The values α∈[1,1.5]\alpha\in[1,1.5] and β=1.04\beta=1.04 are estimated from available calculations of the average electron distances, based on position intracule functions [48, 49]. NoN_o represents the number of electrons in the oo-th orbit of the atom. The mean radii of the xenon atomic orbits were calculated based on a density functional theory (DFT) [50] all-electron calculation with the DFT code GPAW [51]. The results are shown in Table S1.

StateOccupationMean Radius ρo\rho_o [10−10 m10^{-10}\,\mathrm{m}]
1s20.015
2s20.064
2p60.055
3s20.170
3p60.165
3d100.149
4s20.395
4p60.412
4d100.461
5s21.024
5p61.231

Table S1. Orbital properties of the xenon atom.

The CSL spectrum expected for (rCGRW,λGRW)(r_{\mathrm{C}}^{\mathrm{GRW}},\lambda^{\mathrm{GRW}}), as well as the best-fit spectrum, are shown in Figure S-1. The latter is practically identical to the indicated DP best-fit spectrum. Within the constraint of α∈[1,1.5]\alpha\in[1,1.5], the expected integrated signal rate varies by at most ∼1%\sim1\% compared to the rate at α=1.25\alpha=1.25 assumed in the analysis. The limits change by ∼7%\sim7\% for the CSL model and ∼2%\sim2\% in the DP case.

References

  1. [1]Y. Y. Fein, P. Geyer, P. Zwick, F. Kiałka, S. Pedalino, M. Mayor, S. Gerlich, and M. Arndt, Quantum superposition of molecules beyond 25 kDa, Nature Phys. 15, 1242 (2019).DOI
  2. [2]A. Bassi, K. Lochan, S. Satin, T. P. Singh, and H. Ulbricht, Models of Wave-function Collapse, Underlying Theories, and Experimental Tests, Rev. Mod. Phys. 85, 471 (2013).DOI
  3. [3]M. Carlesso, S. Donadi, L. Ferialdi, M. Paternostro, H. Ulbricht, and A. Bassi, Present status and future challenges of non-interferometric tests of collapse models, Nature Phys. 18, 243 (2022).DOI
  4. [4]M. M. Ocampo, M. M. Miller Bertolami, and G. León, Revisiting astrophysical bounds on continuous spontaneous localization models, JCAP 10, 018, arXiv:2406.04463 [quant-ph].DOI
  5. [5]M. Bilardello, S. Donadi, A. Vinante, and A. Bassi, Bounds on collapse models from cold-atom experiments, Physica A: Statistical Mechanics and its Applications 462, 764–782 (2016).DOI
  6. [6]A. Vinante et al., Narrowing the parameter space of collapse models with ultracold layered force sensors, Phys. Rev. Lett. 125, 100404 (2020).DOI
  7. [7]A. Pontin, N. P. Bullier, M. Toroš, and P. F. Barker, Ultranarrow-linewidth levitated nano-oscillator for testing dissipative wave-function collapse, Phys. Rev. Res. 2, 023349 (2020).
  8. [8]S. L. Adler and A. Vinante, Bulk heating effects as tests for collapse models, Phys. Rev. A 97, 052119 (2018).DOI
  9. [9]M. Carlesso, A. Bassi, P. Falferi, and A. Vinante, Experimental bounds on collapse models from gravitational wave detectors, Phys. Rev. D 94, 124036 (2016).DOI
  10. [10]B. Helou, B. Slagmolen, D. E. McClelland, and Y. Chen, LISA Pathfinder appreciably constrains collapse models, Phys. Rev. D 95, 084054 (2017).DOI
  11. [11]M. Carlesso, M. Paternostro, H. Ulbricht, A. Vinante, and A. Bassi, Non-interferometric test of the continuous spontaneous localization model based on rotational optomechanics, New J. Phys. 20, 083022 (2018).DOI
  12. [12]M. Armano et al., Beyond the Required LISA Free-Fall Performance: New LISA Pathfinder Results down to 20 μHz, Phys. Rev. Lett. 120, 061101 (2018).DOI
  13. [13]I. J. Arnquist et al. (Majorana), Search for Spontaneous Radiation from Wave Function Collapse in the Majorana Demonstrator, Phys. Rev. Lett. 129, 080401 (2022), [Erratum: Phys.Rev.Lett. 130, 239902 (2023)].DOI
  14. [14]S. Donadi, K. Piscicchia, C. Curceanu, L. Diósi, M. Laubenstein, and A. Bassi, Underground test of gravity-related wave function collapse, Nature Phys. 17, 74 (2021).DOI
  15. [15]S. Donadi, K. Piscicchia, R. Del Grande, C. Curceanu, M. Laubenstein, and A. Bassi, Novel CSL bounds from the noise-induced radiation emission from atoms, Eur. Phys. J. C 81, 773 (2021).DOI
  16. [16]P. M. Pearle, Combining Stochastic Dynamical State Vector Reduction With Spontaneous Localization, Phys. Rev. A 39, 2277 (1989).pubmed.ncbi.nlm.nih.gov/9901493
  17. [17]G. C. Ghirardi, P. M. Pearle, and A. Rimini, Markov Processes in Hilbert Space and Continuous Spontaneous Localization of Systems of Identical Particles, Phys. Rev. A 42, 78 (1990).pubmed.ncbi.nlm.nih.gov/9903779
  18. [18]L. Diosi, A Universal Master Equation for the Gravitational Violation of Quantum Mechanics, Phys. Lett. A 120, 377 (1987).DOI
  19. [19]L. Diósi, Models for universal reduction of macroscopic quantum fluctuations, Phys. Rev. A 40, 1165 (1989).pubmed.ncbi.nlm.nih.gov/9902248
  20. [20]R. Penrose, On gravity’s role in quantum state reduction, Gen. Rel. Grav. 28, 581 (1996).
  21. [21]G. C. Ghirardi, A. Rimini, and T. Weber, A Unified Dynamics for Micro and Macro Systems, Phys. Rev. D 34, 470 (1986).
  22. [22]L. Figurato, M. Dirindin, J. L. Gaona-Reyes, M. Carlesso, A. Bassi, and S. Donadi, On the effectiveness of the collapse in the Diósi–Penrose model, New J. Phys. 26, 113004 (2024), arXiv:2406.18494 [quant-ph].DOI
  23. [23]K. Piscicchia, S. Donadi, S. Manti, A. Bassi, M. Derakhshani, L. Diósi, and C. Curceanu, X-Ray Emission from Atomic Systems Can Distinguish between Prevailing Dynamical Wave-Function Collapse Models, Phys. Rev. Lett. 132, 250203 (2024).DOI
  24. [24]See Supplemental Material at https://example.com/supplement.pdf for a detailed description of the signal models, which includes Refs. [48–51].
  25. [25]E. Aprile et al. (XENON), Search for New Physics in Electronic Recoil Data from XENONnT, Phys. Rev. Lett. 129, 161805 (2022).
  26. [26]C. E. Dahl, The physics of background discrimination in liquid xenon, and first results from XENON10 in the hunt for WIMP dark matter, Ph.D. thesis, Princeton U. (2009).
  27. [27]E. Aprile et al. (XENON), XENONnT analysis: Signal reconstruction, calibration, and event selection, Phys. Rev. D 111, 062006 (2025).
  28. [28]E. Aprile, C. E. Dahl, L. DeViveiros, R. Gaitskell, K. L. Giboni, J. Kwong, P. Majewski, K. Ni, T. Shutt, and M. Yamashita, Simultaneous measurement of ionization and scintillation from nuclear recoils in liquid xenon as target for a dark matter experiment, Phys. Rev. Lett. 97, 081302 (2006).pubmed.ncbi.nlm.nih.gov/17026288
  29. [29]E. Aprile et al. (XENON), The XENONnT dark matter experiment, Eur. Phys. J. C 84, 784 (2024).DOI
  30. [30]V. C. Antochi et al., Improved quality tests of R11410-21 photomultiplier tubes for the XENONnT experiment, JINST 16 (08), P08033.
  31. [31]E. Aprile et al. (XENON), Conceptual design and simulation of a water Cherenkov muon veto for the XENON1T experiment, JINST 9 (11), P11006.
  32. [32]E. Aprile et al. (XENON), The neutron veto of the XENONnT experiment: results with demineralized water, Eur. Phys. J. C 85, 695 (2025), arXiv:2412.05264 [physics.ins-det].DOI
  33. [33]E. Aprile et al. (XENON), Material radiopurity control in the XENONnT experiment, Eur. Phys. J. C 82, 599 (2022).DOI
  34. [34]G. Plante, E. Aprile, J. Howlett, and Y. Zhang, Liquid-phase purification for multi-tonne xenon detectors, Eur. Phys. J. C 82, 860 (2022).DOI
  35. [35]E. Aprile et al. (XENON), Removing krypton from xenon by cryogenic distillation to the ppq level, Eur. Phys. J. C 77, 275 (2017).DOI
  36. [36]M. Murra, D. Schulte, C. Huhmann, and C. Weinheimer, Design, construction and commissioning of a high-flow radon removal system for XENONnT, Eur. Phys. J. C 82, 1104 (2022).DOI
  37. [37]E. Aprile et al. (XENON), WIMP Dark Matter Search using a 3.1 tonne × year Exposure of the XENONnT Experiment (2025), arXiv:2502.18005 [hep-ex].
  38. [38]E. Aprile et al. (XENON), Detector signal characterization with a Bayesian network in XENONnT, Phys. Rev. D 108, 012016 (2023).DOI
  39. [39]J.-W. Chen, H.-C. Chi, C. P. Liu, and C.-P. Wu, Low-energy electronic recoil in xenon detectors by solar neutrinos, Phys. Lett. B 774, 656 (2017).DOI
  40. [40]E. Aprile et al. (XENON), First Dark Matter Search with Nuclear Recoils from the XENONnT Experiment, Phys. Rev. Lett. 131, 041003 (2023), arXiv:2303.14729 [hep-ex].DOI
  41. [41]E. Aprile et al. (XENON), Excess electronic recoil events in XENON1T, Phys. Rev. D 102, 072004 (2020).DOI
  42. [42]S. Baker and R. D. Cousins, Clarification of the Use of Chi Square and Likelihood Functions in Fits to Histograms, Nucl. Instrum. Meth. 221, 437 (1984).
  43. [43]C. Alduino et al. (CUORE), The projected background for the CUORE experiment, Eur. Phys. J. C 77, 543 (2017).DOI
  44. [44]M. Toroš, G. Gasbarri, and A. Bassi, Colored and dissipative continuous spontaneous localization model and bounds from matter-wave interferometry, Physics Letters A 381, 3921–3927 (2017).DOI
  45. [45]S. L. Adler, Lower and Upper Bounds on CSL Parameters from Latent Image Formation and IGM Heating, J. Phys. A 40, 2935 (2007), [Erratum: J.Phys.A 40, 13501 (2007)].
  46. [46]G. C. Ghirardi, A. Rimini, and T. Weber, Unified dynamics for microscopic and macroscopic systems, Phys. Rev. D 34, 470 (1986).pubmed.ncbi.nlm.nih.gov/9957165
  47. [47]S. L. Adler and A. Bassi, Collapse models with non-white noises, Journal of Physics A: Mathematical and Theoretical 40, 15083–15098 (2007).DOI
  48. [48]C. Coulson and A. Neilson, Electron correlation in the ground state of helium, Proceedings of the Physical Society (1958-1967) 78, 831 (1961).DOI
  49. [49]P. M. Gill, D. P. O’Neill, and N. A. Besley, Two-electron distribution functions and intracules, Theoretical Chemistry Accounts 109, 241 (2003).DOI
  50. [50]W. Kohn and L. J. Sham, Self-Consistent Equations Including Exchange and Correlation Effects, Phys. Rev. 140, A1133 (1965).DOI
  51. [51]J. J. Mortensen et al., GPAW: An open Python package for electronic structure calculations, The Journal of Chemical Physics 160, 10.1063/5.0182685 (2024).

Paper details

vlnc:W_rqspash8
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 0

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents