Magnetic Field-Controlled Mixed Modulation in Magnetoelectric Sensors

Abstract

Magnetoelectric (ME) magnetic field sensors commonly rely on one of the two modulation principles: the nonlinear dependence of magnetostrictive strain on the applied field or the stress-induced change in magnetization susceptibility. While both effects coexist in any ME device, different readout schemes can be chosen to utilize one or the other effect for magnetic field sensing. This work demonstrates that both principles can be simultaneously implemented in a single electrically modulated ME sensor with inductive readout (a converse ME sensor). This mixed modulation approach significantly enhances low-frequency sensitivity while not affecting the sensitivity at higher frequencies. This leads to a nontrivial dependency of the sensor sensitivity on the frequency of the magnetic field to be measured and can effectively decrease the sensor bandwidth by up to an order of magnitude. We show that the contribution of the modulation from the nonlinearity of the magnetostrictive strain to the sensor sensitivity can be changed by applying a magnetic bias field, offering an additional dimension to the design of ME sensors, especially for potential applications in the unshielded environment.

Introduction

Magnetic field sensors play a crucial role in a wide range of modern applications, including wireless communication systems[1] and biomedical diagnostics[2]. The latter often require detection of extremely weak magnetic fields at low frequencies below 10 kHz with a bandwidth of up to 1 kHz. [3] Recent decades saw substantial progress in the development of magnetic field sensors that target these applications, including sensor concepts utilizing magnetoelectric (ME) composite materials.[4, 5, 6] Such materials comprise mechanically coupled piezoelectric and magnetostrictive components, allowing the conversion of magnetic fields into electrical voltage (direct ME effect) and vice versa (converse ME effect) with a much higher conversion factor in comparison to the single-phase ME materials.[7]

Various magnetic field sensor concepts based on the ME effect have been presented; many of them utilize resonator structures, such as cantilevers.[4] A typical ME cantilever consists of three main components: a piezoelectric layer sandwiched between two electrodes, a silicon substrate, and a magnetostrictive layer on the rear side of the substrate. The sensitivity of the sensors based on the direct ME effect is significantly amplified when the frequency facf_{\mathrm{ac}} of the magnetic field to be measured HacH_{\mathrm{ac}} matches the resonance frequency frf_r of the sensor element. Extremely low limits of detection of a few pT/Hz1/2\mathrm{Hz}^{1/2} have been achieved in this operation mode,[8] however, restricted to narrow-band signals near frf_r.

Modulation techniques based on the nonlinearity of magnetostriction have been employed to detect low-frequency, low-amplitude magnetic fields over broader frequency ranges.[9]

Examples include concepts based on the ΔE\Delta E and converse ME effects.[4] These concepts correspondingly employ the dependency of the magnetostrictive strain[10] and the susceptibility of magnetization to stress[11] on the applied magnetic field. Although both modulation techniques have been comprehensively studied in the literature[9, 10, 11, 12, 13], the case of mixed modulation and its effect on the signal and bandwidth of converse ME sensors was not investigated. Yet, it is expected that the ΔE\Delta E effect in the magnetostrictive layer will lead to the mixed modulation of magnetization oscillation in converse ME sensors and, by that, make some contribution to the sensitivity of such sensors. Here, we explain how significant this contribution is and how it changes depending on the applied magnetic bias field. Furthermore, we demonstrate its crucial effect on the sensor sensitivity as a function of the frequency of the measured field, which ultimately determines the bandwidth of the magnetic field sensor and results in a complex dependency of the bandwidth on the bias field.

Results

Sensor Concept and Mixed Modulation Principle

Modulation Principle based on the ΔE\Delta E effect

The ΔE\Delta E effect manifests in the dependency of the stiffness tensor of the magnetostrictive material on the magnetostrictive strain and its nonlinear dependency on the magnetic field.[10]

In the case of cantilever-based sensors, the change in the stiffness of the magnetostrictive layer causes a change of frf_r, which can be read out optically,[14] electrically,[15, 16] or inductively.[17]

For low amplitudes of an alternating field HacH_{\mathrm{ac}}, oscillation of frf_r around fr(Hac=0)f_r(H_{\mathrm{ac}} = 0) can be approximated as

fr(t)=fr(Hac=0)+∂fr∂HHac(t),(1)f_r(t) = f_r(H_{\mathrm{ac}} = 0) + \frac{\partial f_r}{\partial H} H_{\mathrm{ac}}(t), \tag*{(1)}

with the time tt. The shift of frf_r with HacH_{\mathrm{ac}} can be calculated via the change ΔS\Delta S of the compliance tensor SS.[13]

Sij=∂(εi+λi)∂σj=S0,ij+ΔSij,i,j∈{1…6},(2)S_{ij} = \frac{\partial(\varepsilon_i + \lambda_i)}{\partial\sigma_j} = S_{0,ij} + \Delta S_{ij}, \quad i,j \in\{1 \ldots6\}, \tag*{(2)}
∂fr∂H∝∂Sij∂H=∂∂H∂λi∂σj\frac{\partial f_r}{\partial H} \propto\frac{\partial S_{ij}}{\partial H} = \frac{\partial}{\partial H}\frac{\partial\lambda_i}{\partial\sigma_j}

where ε\varepsilon is the mechanical strain. For the bending modes, frf_r is determined by SiiS_{ii}. Hence,

∂fr∂H∝∂Sii∂H=∂∂H∂λi∂σi=3λs∂miχiiσ∂H,(3)\frac{\partial f_r}{\partial H} \propto\frac{\partial S_{ii}}{\partial H} = \frac{\partial}{\partial H}\frac{\partial\lambda_i}{\partial\sigma_i} = 3\lambda_s\frac{\partial m_i\chi_{ii}^{\sigma}}{\partial H}, \tag*{(3)}

where χiiσ:=∂mi/∂σi\chi_{ii}^{\sigma} := \partial m_i/\partial\sigma_i is the susceptibility of magnetization to stress and λs\lambda_s is saturation magnetostriction constant. The sensitivity of the magnetic field sensors based on the ΔE\Delta E effect is determined by the change of its resonance frequency, which means that the mechanical bandwidth of the cantilever determines the sensor bandwidth.[15]

Modulation Principle based on the Converse ME Effect

An alternative approach that allows broadband signal detection is based on the converse ME effect and the inductive readout of the magnetization change. An illustration of a converse ME sensor and the coordinate system used in this letter is shown in the inset of Figure 1a. In this operation mode, the cantilever is excited at its mechanical resonance by applying the excitation voltage uexu_{\mathrm{ex}} between the electrodes with a frequency fex=frf_{\mathrm{ex}} = f_r. The induced stress σ(t)∝uex(t)\boldsymbol{\sigma}(t) \propto u_{\mathrm{ex}}(t) in the magnetostrictive layer causes the oscillation of magnetization m\boldsymbol{m}. If the amplitude of σ(t)\boldsymbol{\sigma}(t) is small, the oscillation of m\boldsymbol{m} can be described via the susceptibility χijσ:=∂mi/∂σj\chi_{ij}^{\sigma} := \partial m_i/\partial\sigma_j. The external magnetic field Hac(t)H_{\mathrm{ac}}(t) modulates χijσ\chi_{ij}^{\sigma} leading to the modulation of m\boldsymbol{m} as illustrated in Figure 1b. The resulting oscillation of magnetization can be expressed as[11]

Illustration of the sensor concept

Figure 1. Illustration of the sensor concept. (a) Calculated dependency of ∂χ12σ/∂H1\partial\chi_{12}^{\sigma}/\partial H_{1} and ∂m2χ22σ/∂H1\partial m_{2}\chi_{22}^{\sigma}/\partial H_{1} that correspondingly determine the sensitivity of converse ME and ΔE\Delta E-effect sensors on the magnetic bias field μ0Hdc\mu_{0}H_{\mathrm{dc}}. The dependencies are calculated for two orientations of the easy axis (EA) of the uniaxial magnetic anisotropy: along the x2x_{2}-axis (solid lines) and tilted by 2.6∘2.6^\circ relative to the x2x_{2}-axis (dashed lines). Inset: the coordinate system used throughout the paper and a schematic illustration of the sensor element comprising the ME cantilever and the pickup coil. (b) Converse ME effect: applied stress σ\sigma induces oscillation of magnetization proportional to χ12σ\chi_{12}^{\sigma} modulated by HacH_{\mathrm{ac}}. The amplitude spectrum of the signal uoutu_{\mathrm{out}} read out with the pickup coil is shown on the right. The main peak in the center is the carrier with an amplitude ∣Uc∣\lvert U_{\mathrm{c}}\rvert, the amplitude of the sidebands ∣Us∣\lvert U_{\mathrm{s}}\rvert determines the sensitivity of the sensor to the magnetic field. This case illustrates amplitude modulation (AM) of the carrier. (c) ΔE\Delta E effect: HacH_{\mathrm{ac}} shifts the frequency dependency of the carrier magnitude ∣Uc∣\lvert U_{\mathrm{c}}\rvert and phase arg⁡{uc}\arg\{u_{\mathrm{c}}\}. This leads a amplitude (AM) and phase (PM) modulation of ucu_{\mathrm{c}} illustrated with the green arrows. (d) Mixed modulation case. The ΔE\Delta E effect causes amplitude and phase modulation (AM+PM) of σ\sigma, which induces oscillation of M∝χ12σM \propto\chi_{12}^{\sigma} modulated by HacH_{\mathrm{ac}}. Amplitude spectrum of the output signal is shown on the right. AM of σ\sigma creates harmonic distortion, i.e., additional signal peaks at fex±2facf_{\mathrm{ex}} \pm2f_{\mathrm{ac}}, PM of σ\sigma increases the main signal peak ∣Us∣\lvert U_{\mathrm{s}}\rvert by adding additional contribution ∣Us,ΔE∣\lvert U_{\mathrm{s},\Delta E}\rvert.

mi(t)=[χijσ+∂χijσ∂HlHac,l(t)]σj(t).(4)m_i(t) = \left[\chi_{ij}^{\sigma} + \frac{\partial\chi_{ij}^{\sigma}}{\partial H_l}H_{\mathrm{ac},l}(t)\right]\sigma_j(t). \tag*{(4)}

This oscillation of magnetization is then read out inductively with a pickup coil.[18, 19] This sensor concept significantly differs from the other ME sensor concepts because in this case, the readout signal is determined by the magnetization change and not the magnetostrictive strain. This removes the restriction on the sensor bandwidth imposed by resonator bandwidth. Reported values of the sensor bandwidth can reach several kilohertz, which is ten times larger than the corresponding resonator bandwidth.[6, 11] In the following, we show that this is true only within a narrow range of the operation parameters, within which the ΔE\Delta E effect is negligible.

Because of the geometry of the sensor element and the used resonance mode, often referred to as the U-mode,[5, 11, 19, 20] we can consider only the x1x_1-axis components of mm and HH, and the x2x_2-axis component of σ\boldsymbol{\sigma} and λ\boldsymbol{\lambda}, i.e., i=1,j=2,l=1i=1,j=2,l=1 in Eq. (4) and i=2i=2 in Eq. (3).[11]

Oscillation of magnetization is recorded using a pickup coil connected to a low-noise operational amplifier, which is then connected to the input of a lock-in amplifier. The same lock-in amplifier provides an auxiliary output for sensor excitation. Details about the setup have been presented elsewhere.[5, 11, 19] The resulting output voltage uout(t)u_{\mathrm{out}}(t) at the input of the lock-in amplifier can be approximated as

uout(t)≈A⋅∂m(t)/∂t,(5)u_{\mathrm{out}}(t) \approx A \cdot\partial m(t)/\partial t, \tag*{(5)}

where AA is a proportionality factor determined by the geometry of the resonator, the pickup coil, and readout electronics. For the device investigated here, A≈15.4A \approx15.4 mVs. The detailed derivation and validation of Eq. (4)-(5) and the coefficient AA is provided in Ref. [11] as a part of the comprehensive sensor system model.

The first term in Eq. (4) describes the oscillation of magnetization caused by the applied stress σ\sigma and determines the root-mean-square (RMS) amplitude UcU_{\mathrm{c}} of the carrier signal uc=2Ucsin⁡(2πfext)u_{\mathrm{c}}=\sqrt{2}U_{\mathrm{c}}\sin(2\pi f_{\mathrm{ex}}t) (denoted on the right in Figure 1b). The second term in Eq. (4) describes the modulation of χijσ\chi_{ij}^{\sigma} caused by HacH_{\mathrm{ac}}. It represents the modulation of the carrier and the corresponding amplitude UsU_{\mathrm{s}} of the sidebands visible in the frequency domain, as illustrated in Figure 1b. Because UsU_{\mathrm{s}} is linearly proportional to ∂χ12σ/∂H1\partial\chi_{12}^{\sigma}/\partial H_1, the dependency of UsU_{\mathrm{s}} on the bias field μ0Hdc\mu_0H_{\mathrm{dc}} can be qualitatively analyzed by calculating the dependency of ∂χ12σ/∂H1\partial\chi_{12}^{\sigma}/\partial H_1 on the bias field μ0Hdc\mu_0H_{\mathrm{dc}}. The dependency calculated using a macrospin model is plotted on the left vertical axis of Figure 1a. Details of the model and material parameters used are provided in the Methods.

The easy axis (EA) of uniaxial magnetic anisotropy is set along the x2x_{2}-axis (solid lines) and tilted by 2.6∘2.6^\circ relative to the x2x_{2}-axis (dashed lines). The tilt of the EA is introduced to mimic the limited manufacturing control and a possible slight deviation from the exact orientation of EA along the x2x_{2}-axis. Figure 1a shows that if the EA is parallel to the x2x_{2}-axis, ∂χ12σ/∂H1\partial\chi_{12}^{\sigma}/\partial H_{1} and, hence, the sensitivity of the converse ME sensor should stay constant within a certain range of μ0Hdc\mu_{0}H_{\mathrm{dc}}. The tilt of EA causes the tilt of the ∂χ12σ/∂H1\partial\chi_{12}^{\sigma}/\partial H_{1} curve.

With the same macrospin model, the dependency of ∂m2χ22σ/∂H1\partial m_{2}\chi_{22}^{\sigma}/\partial H_{1}, which determines the sensitivity of the ΔE\Delta E-effect sensors (Eq. (3)) on the bias field μ0Hdc\mu_{0}H_{\mathrm{dc}} is calculated and plotted in Figure 1a. In contrast to ∂χ12σ/∂H1\partial\chi^{\sigma}_{12}/\partial H_{1}, ∂m2χ22σ/∂H1\partial m^{2}\chi^{\sigma}_{22}/\partial H_{1} increases almost quadratically with μ0Hdc\mu_{0}H_{\mathrm{dc}}, which results in the typical dependency of ∂fr/∂H\partial f_{\mathrm{r}}/\partial H on μ0Hdc\mu_{0}H_{\mathrm{dc}} for such samples [13, 21]. The tilt of the EA causes the shift of the minimum of the ∂m2χ22σ/∂H1\partial m^{2}\chi^{\sigma}_{22}/\partial H_{1} curve.

Fig 1a highlights the main difference between the ME sensor concepts whose sensitivity is determined by the magnetostrictive strain λ\lambda and those whose sensitivity is determined by the magnetization change. Under ideal conditions, in the sensor configuration considered here, the sensitivity is nearly quadratic with HH in the first case and linear in the second case. In the following, we show that the ΔE\Delta E effect contributes significantly to the signal of converse ME sensors, leading to a nontrivial dependency of the sensor signal and bandwidth on the bias field.

Mixed Modulation. Combination of the Converse ME and ΔE\Delta E Effects

To include the contribution of the ΔE\Delta E effect to the sensor signal, we need to consider the modulation of the resonance frequency frf_{\mathrm{r}} of the cantilever induced by HacH_{\mathrm{ac}}. The modulation of frf_{\mathrm{r}} results in the shift of the frequency dependency of the carrier magnitude UcU_{\mathrm{c}} and phase arg⁡{uc}\operatorname{arg}\{u_{\mathrm{c}}\} as illustrated in Figure 1c. Consequently, if the excitation frequency fex=fr(Hac=0)f_{\mathrm{ex}}=f_{\mathrm{r}}(H_{\mathrm{ac}}=0) is kept constant, the modulation of frf_{\mathrm{r}} leads to amplitude (AM) and phase modulation (PM) of ucu_{\mathrm{c}} (highlighted with a green arrow in Figure 1c). If the cantilever is excited exactly at its resonance frequency, the corresponding modulation of σ(t)\sigma(t) (Figure 1d) can be expressed as

σ(t)=(σ0+SaHac(t)2)sin⁡(2πfext+φσ+SpHac(t)).(6)\sigma(t) = \left(\sigma_{0} + S_{\mathrm{a}}H_{\mathrm{ac}}(t)^{2}\right)\sin\left(2\pi f_{\mathrm{ex}}t + \varphi_{\sigma} + S_{\mathrm{p}}H_{\mathrm{ac}}(t)\right). \tag*{(6)}

Here, σ0\sigma_{0} is the amplitude of σ\sigma, φσ\varphi_{\sigma} is a phase lag between uexu_{\mathrm{ex}} and σ\sigma for ∣Hac∣=0\lvert H_{\mathrm{ac}}\rvert=0, SaS_{\mathrm{a}} is amplitude sensitivity, and SpS_{\mathrm{p}} is the phase sensitivity expressed as

Sp≔∂arg⁡{σ}∂H=∂arg⁡{σ}∂f∣f=fr∂fr∂H∣H=Hdc.(7)S_{\mathrm{p}} \coloneqq\frac{\partial\operatorname{arg}\{\sigma\}}{\partial H} = \left.\frac{\partial\operatorname{arg}\{\sigma\}}{\partial f}\right|_{f=f_{\mathrm{r}}}\left.\frac{\partial f_{\mathrm{r}}}{\partial H}\right|_{H=H_{\mathrm{dc}}}. \tag*{(7)}

The amplitude modulation of σ\sigma creates harmonic distortion, visible as additional signal peaks at fex±2facf_{\mathrm{ex}}\pm2f_{\mathrm{ac}} in fig:1d. For the sake of clarity, we restrict our discussion to the impact of the ΔE\Delta E effect on the main signal peak and assume Sa=0S_{\mathrm{a}}=0.

Plugging (7) into (4) and (5) gives the final expression for the output signal that combines both the converse ME and the ΔE\Delta E effects, as illustrated in fig:1d

uout=A∂∂t[σ0sin⁡(2πfext+φσ+SpHac(t))(χσ+∂χσ∂HHac(t))].(8)u_{\mathrm{out}}=A\frac{\partial}{\partial t}\left[\sigma_0\sin\left(2\pi f_{\mathrm{ex}}t+\varphi_\sigma+S_{\mathrm{p}}H_{\mathrm{ac}}(t)\right)\left(\chi^\sigma+\frac{\partial\chi^\sigma}{\partial H}H_{\mathrm{ac}}(t)\right)\right]. \tag*{(8)}

SpS_{\mathrm{p}} can be calculated with, e.g., a finite-element model of the magnetoelectrical resonator, as was described in [22]. However, to avoid these computationally expensive calculations, SpS_{\mathrm{p}} can be estimated from measurements via

Sp≈∂arg⁡{uc}∂H=∂arg⁡{uc}∂f∣f=fr∂fr∂H∣H=Hdc,(9)S_{\mathrm{p}}\approx\frac{\partial\arg\{u_{\mathrm{c}}\}}{\partial H}=\left.\frac{\partial\arg\{u_{\mathrm{c}}\}}{\partial f}\right|_{f=f_{\mathrm{r}}}\left.\frac{\partial f_{\mathrm{r}}}{\partial H}\right|_{H=H_{\mathrm{dc}}}, \tag*{(9)}

where ucu_{\mathrm{c}} is the measured carrier signal of the sensor. The contribution Us,ΔEU_{\mathrm{s},\Delta E} of the ΔE\Delta E effect to UsU_{\mathrm{s}} can be then estimated as

Us,ΔE=Lfac[Ucsin⁡(2πfext+SpHac(t))],(10)U_{\mathrm{s},\Delta E}=\mathcal{L}_{f_{\mathrm{ac}}}\left[U_{\mathrm{c}}\sin\left(2\pi f_{\mathrm{ex}}t+S_{\mathrm{p}}H_{\mathrm{ac}}(t)\right)\right], \tag*{(10)}

where Lfac\mathcal{L}_{f_{\mathrm{ac}}} denotes lock-in demodulation of the time-domain signal and selection of its value at facf_{\mathrm{ac}}.

Influence of the Mixed Modulation on the Signal and Bandwidth of the ME Sensor

In this section, we will demonstrate how the described contribution of the ΔE\Delta E effect affects the output signal of a converse ME sensor.

Signal

The measured sideband amplitude UsU_{\mathrm{s}} as a function of the magnetic bias field HdcH_{\mathrm{dc}} is shown in Figure 2a. A test field HacH_{\mathrm{ac}} with μ0∣Hac∣=10\mu_0|H_{\mathrm{ac}}|=10 nT and fac=10f_{\mathrm{ac}}=10 Hz was used for the measurements. Figure 2a shows that UsU_{\mathrm{s}} reaches its minimum of Us=22U_{\mathrm{s}}=22 µV at μ0Hdc=−0.05\mu_0H_{\mathrm{dc}}=-0.05 mT and increases with increasing ∣μ0Hdc∣|\mu_0H_{\mathrm{dc}}| reaching Us=38U_{\mathrm{s}}=38 µV at μ0Hdc=0.2\mu_0H_{\mathrm{dc}}=0.2 mT. The contribution of the ΔE\Delta E effect Us,ΔEU_{\mathrm{s},\Delta E} estimated from the measurements with Eq. (10) and the corresponding change in the resonance frequency frf_{\mathrm{r}} is also plotted in Figure 2a. Us,ΔEU_{\mathrm{s},\Delta E} follows the same trend as UsU_{\mathrm{s}}, showing its minimum of Us,ΔE=2U_{\mathrm{s},\Delta E}=2 µV at μ0Hdc=−0.05\mu_0H_{\mathrm{dc}}=-0.05 mT and reaching a maximum of Us,ΔE=36U_{\mathrm{s},\Delta E}=36 µV at μ0Hdc=0.2\mu_0H_{\mathrm{dc}}=0.2 mT. The resonance frequency frf_{\mathrm{r}} shows the opposite trend, reaching the maximum at μ0Hdc=−0.05\mu_0H_{\mathrm{dc}}=-0.05 mT and decreasing with increasing ∣μ0Hdc∣|\mu_0H_{\mathrm{dc}}|. Such dependency of frf_{\mathrm{r}} on μ0Hdc\mu_0H_{\mathrm{dc}} is expected from the ΔE\Delta E effect for the current configuration of the uniaxial magnetic anisotropy and the applied anisotropic stress axis.[13] The increasing change of frf_{\mathrm{r}} with μ0Hdc\mu_{0}H_{\mathrm{dc}} leads to higher Us,ΔEU_{\mathrm{s},\Delta E} (Eq. (7),(10)), which exceeds 50% of UsU_{\mathrm{s}} at μ0Hdc>0.075\mu_{0}H_{\mathrm{dc}} > 0.075 mT.

Impact of the $\Delta E$ effect on the signal of the converse ME sensor as a function of the bias field

Figure 2. Impact of the ΔE\Delta E effect on the signal of the converse ME sensor as a function of the bias field HdcH_{\mathrm{dc}}. (a) Left axis: measured sideband amplitude ∣Us∣\lvert U_{\mathrm{s}}\rvert for ∣uex∣=0.1\lvert u_{\mathrm{ex}}\rvert= 0.1 V and the contribution ∣Us,ΔE∣\lvert U_{\mathrm{s},\Delta E}\rvert of the ΔE\Delta E effect to ∣Us∣\lvert U_{\mathrm{s}}\rvert estimated with Eq. (10). Right axis: resonance frequency frf_{\mathrm{r}} of the sensor element. (b) Simulated sideband amplitude ∣Us∣\lvert U_{\mathrm{s}}\rvert with and without considering the ΔE\Delta E effect.

Additionally, we performed a simulation of uoutu_{\mathrm{out}} with Eq. (7) using the same sensor signal model as in Ref. [11]. The phase sensitivity SpS_{\mathrm{p}} is estimated from the measurements using Eq. (9). The sideband amplitude ∣Us∣\lvert U_{\mathrm{s}}\rvert was then calculated as ∣Us,ΔE∣=Lfac(uout)\lvert U_{\mathrm{s},\Delta E}\rvert= \mathcal{L}_{f_{\mathrm{ac}}}(u_{\mathrm{out}}). The resulting dependencies of ∣Us∣\lvert U_{\mathrm{s}}\rvert on μ0Hdc\mu_{0}H_{\mathrm{dc}} for two cases, with and without the ΔE\Delta E effect, are plotted in Figure 2b. While without the ΔE\Delta E effect, ∣Us∣\lvert U_{\mathrm{s}}\rvert barely changes with μ0Hdc\mu_{0}H_{\mathrm{dc}}, with the ΔE\Delta E effect, ∣Us∣\lvert U_{\mathrm{s}}\rvert increases with increasing field magnitude following the increasing SpS_{\mathrm{p}}, as expected from Fig, 1a. This increase of UsU_{\mathrm{s}} perfectly resembles the trend in the measured data (Figure 2a). Overall, the data indicate that the contribution of the ΔE\Delta E effect can increase the output signal ∣Us∣\lvert U_{\mathrm{s}}\rvert of the sensor system.

Bandwidth

According to Eq. (4), the bandwidth of the converse ME sensors should be determined by the frequency dependency of the susceptibility χσ\chi^{\sigma} i.e., by the magneto-mechanical loss in the magnetostrictive layer.[11] At the same time, the bandwidth of the ΔE\Delta E-effect sensors is determined by the effective loss of the cantilever, i.e., the mechanical resonator as a whole.[15] Consequently, the bandwidth of the ΔE\Delta E-effect sensors is narrower in comparison to the converse ME sensors.[6, 11] However, if the ΔE\Delta E effect dominates the signal of the converse ME sensor, the bandwidth of the mechanical resonator should become the dominating factor determining the sensor bandwidth.

To prove this hypothesis, we measured both sensor and the resonator bandwidth over the bias field μ0Hdc\mu_0 H_{\mathrm{dc}}. To estimate the mechanical bandwidth of the resonator Δfc\Delta f_{\mathrm{c}}, the carrier amplitude ∣Uc∣\lvert U_{\mathrm{c}}\rvert is measured as a function of the excitation frequency ff, assuming that ∣Uc∣\lvert U_{\mathrm{c}}\rvert is directly proportional to the displacement of the cantilever. The result of the measurement performed at ∣uex∣=0.1\lvert u_{\mathrm{ex}}\rvert= 0.1 V and μ0Hdc=0\mu_0 H_{\mathrm{dc}} = 0 mT is plotted in Figure 3a. The mechanical bandwidth Δfc\Delta f_{\mathrm{c}} of the resonator, estimated as half-width at half-power[23] is Δfc≈100\Delta f_{\mathrm{c}} \approx100 Hz.

Impact of the $\Delta E$ effect on the sensor bandwidth

Figure 3. Impact of the ΔE\Delta E effect on the sensor bandwidth. (a) Carrier heights ∣Uc∣\lvert U_{\mathrm{c}}\rvert as a function of the excitation frequency ff. The resonator bandwidth Δfc\Delta f_{\mathrm{c}} calculated as half of the half-power bandwidth of ∣Uc∣\lvert U_{\mathrm{c}}\rvert is highlighted in green. (b) Dependency of the sensor signal ∣Us∣\lvert U_{\mathrm{s}}\rvert as a function of the magnetic field frequency facf_{\mathrm{ac}} recorded at different magnitudes HdcH_{\mathrm{dc}} of the magnetic bias field. The values are normalized to ∣Us∣(fac=10 Hz)\lvert U_{\mathrm{s}\rvert}(f_{\mathrm{ac}} = 10\ \mathrm{Hz}) for each ∣μ0Hdc∣\lvert\mu_0 H_{\mathrm{dc}}\rvert value individually. (c) Dependency of the sensor bandwidth Δfs\Delta f_{\mathrm{s}} and the contribution of the ΔE\Delta E effect to the sensor signal kΔE=∣Us,ΔE∣/∣Us∣k_{\Delta E} = \lvert U_{\mathrm{s},\Delta E}\rvert/\lvert U_{\mathrm{s}}\rvert on the bias field HdcH_{\mathrm{dc}}.

The sensor bandwidth is estimated by sweeping the frequency facf_{\mathrm{ac}} of the applied alternating field μ0Hac\mu_0 H_{\mathrm{ac}} with μ0Hac=100\mu_0 H_{\mathrm{ac}} = 100 nT and measuring the height ∣Us∣\lvert U_{\mathrm{s}}\rvert of the signal peak facf_{\mathrm{ac}}. The resulting dependency ∣Us∣(fac)\lvert U_{\mathrm{s}}\rvert(f_{\mathrm{ac}}) normalized to ∣Us∣(fac=10 Hz)\lvert U_{\mathrm{s}}\rvert(f_{\mathrm{ac}} = 10\ \mathrm{Hz}) recorded at μ0Hdc={0…0.15}\mu_0 H_{\mathrm{dc}} = \{0 \ldots0.15\} mT is plotted in Figure 3b. At μ0Hdc=0\mu_0 H_{\mathrm{dc}} = 0 mT, the dependency shows the expected low-pass behavior.[25, 28] At μ0Hdc=0.05\mu_0 H_{\mathrm{dc}} = 0.05 mT and μ0Hdc=0.1\mu_0 H_{\mathrm{dc}} = 0.1 mT, the shape of the curve changes, showing two overlapping resonators with different bandwidths.

The resonator with the smaller bandwidth represents the mechanical resonator, and the resonator with the larger bandwidth represents the mechanically driven magnetic resonator. At μ0Hdc=0.15\mu_0 H_{\mathrm{dc}} = 0.15 mT, the contribution of the ΔE\Delta E effect becomes dominant, and the sensor bandwidth reaches its minimum value equal to the bandwidth of the mechanical resonator.

From the measured dependency ∣Us∣(fac,μ0Hdc)|U_{\mathrm{s}}|(f_{\mathrm{ac}}, \mu_0 H_{\mathrm{dc}}) a -3 dB bandwidth Δfs\Delta f_{\mathrm{s}} is calculated and plotted in Figure 3b as a function of the bias field μ0Hdc\mu_0 H_{\mathrm{dc}}. For comparison, the contribution of the ΔE\Delta E effect to the sensor signal calculated as kΔE=∣Us,ΔE∣/∣Us∣k_{\Delta E} = |U_{\mathrm{s,\Delta E}}|/|U_{\mathrm{s}}| is plotted on the right vertical axis of Figure 3b. Around μ0Hdc=−0.05\mu_0 H_{\mathrm{dc}} = -0.05 mT, the sensor bandwidth bb reaches its maximum of Δfs=1990\Delta f_{\mathrm{s}} = 1990 Hz. At the same μ0Hdc\mu_0 H_{\mathrm{dc}}, the contribution of the ΔE\Delta E effect is the lowest with kΔE≈1k_{\Delta E} \approx1 %. With the increasing contribution of the ΔE\Delta E effect, the bandwidth decreases, reaching its minimum level of Δfs=120\Delta f_{\mathrm{s}} = 120 Hz at μ0Hdc=0.15\mu_0 H_{\mathrm{dc}} = 0.15 mT. For μ0Hdc≥0.1\mu_0 H_{\mathrm{dc}} \ge0.1 mT the contribution kΔEk_{\Delta E} of the ΔE\Delta E effect exceeds 50%, resulting in the narrow sensor bandwidth Δfs<150\Delta f_{\mathrm{s}} < 150 Hz (marked red in Figure 3b). The same correlation between increasing kΔEk_{\Delta E} and decreasing Δfs\Delta f_{\mathrm{s}} is also visible in the negative fields μ0Hdc<0\mu_0 H_{\mathrm{dc}} < 0. The Δfs(μ0Hdc)\Delta f_{\mathrm{s}}(\mu_0 H_{\mathrm{dc}}) curve is asymmetrical around μ0Hdc=0\mu_0 H_{\mathrm{dc}} = 0 mT because of the tilt of the magnetic anisotropy axis, as was mentioned before. A clear correlation between the ΔE\Delta E effect and the sensor bandwidth is visible, confirming our hypothesis.

Conclusion

This paper demonstrates that the ΔE\Delta E effect plays a crucial role in the performance of magnetoelectric sensors with inductive readout (converse ME sensors). During the operation of such sensors, the ΔE\Delta E effect causes amplitude and phase modulation of the stress within the magnetostrictive layer, leading to a mixed modulation of magnetization oscillation. It results in an increase of the signal at low frequencies and a nontrivial frequency dependency of the output signal, leading to a sensor bandwidth that strongly depends on the magnetic bias field.

Notably, in the case of the investigated sensor, the volume fraction of the magnetostrictive material relative to the substrate and other functional layers is about three times smaller compared to reported ΔE\Delta E-effect sensors.[15, 16, 22, 24] Still, as we have shown, the impact of the ΔE\Delta E effect cannot be neglected. This implies that magnetoelastic nonlinearities and other effects connected with the ΔE\Delta E effect[22, 25] are also relevant for designing converse ME sensors, especially if they are intended to be used in an unshielded environment. Design strategies investigated for ΔE\Delta E-effect sensors[24, 26] could be transferred to converse ME sensors to tune the contribution of the ΔE\Delta E effect and potentially benefit from this second signal pathway. For suppressing the contribution of the ΔE\Delta E effect, higher thickness ratios of the substrate to the magnetostrictive layer might be considered. Likewise, to achieve a higher magnetic field tunability of the bandwidth, a larger contribution of the ΔE\Delta E effect to the signal would be beneficial, which can be achieved by reducing the substrate thickness. Increasing the thickness of the magnetostrictive layer can increase the signal contribution from the converse ME and the ΔE\Delta E effect.

Additionally, the results show the possibility of tuning the bandwidth and signal output of the sensor system by carefully adjusting operational parameters, which offers an additional dimension to the design of ME sensors. Hence, this work contributes to the fundamental understanding of magnetoelectric magnetic field sensors and marks a significant step towards tailoring magnetoelectric devices to specific applications in the future.

Methods

Signal measurement. The signal measurements were performed with a lock-in amplifier HF2LI from Zurich Instruments and a low-noise operational amplifier LT1363 (from Analog Devices) in non-inverting op-amp configuration. The alternating magnetic field μ0Hac\mu_{0}H_{\mathrm{ac}} and static magnetic field μ0Hdc\mu_{0}H_{\mathrm{dc}} were created with two coaxial solenoids and two low-noise current sources (6221, Keithley Instruments, Solon, USA). The measurements were performed in a magnetically, electrically, and acoustically shielded environment, including an additional multilayer mu-metal cylinder (Model ZG1, Aaronia).[27]

Macrospin model. The macrospin model used for calculating χ12σ\chi^{\sigma}_{12} and χ22σ\chi^{\sigma}_{22} includes uniaxial magnetic anisotropy, stress-induced anisotropy, and Zeeman energy. Details of the model are provided elsewhere.[11] The saturation magnetostriction constant λs\lambda_{\mathrm{s}}, effective magnetic anisotropy constant KuK_{\mathrm{u}}, and magnetic anisotropy angle θ\theta relative to x2x_{2} are set to λs=30\lambda_{\mathrm{s}} = 30 ppm,[28] Ku=1120K_{\mathrm{u}} = 1120 J/m3^{3}, and θ=2.6∘\theta= 2.6^{\circ}.

Acknowledgements

The research was supported by the German Research Foundation (DFG) through the Collaborative Research Centre CRC 1261 “Magnetoelectric Sensors – From Composite Materials to Biomagnetic Diagnostics” and by the Carl Zeiss foundation via the project “Memristive Materials for Neuromorphic Electronics” (MemWerk).

We would like to thank our colleagues Jingxiang Su and Florian Niekiel from Fraunhofer ISITS in Itzehoe for deposition of the piezoelectric AlN and providing the silicon wafers as part of the CRC 1261.

References

  1. [1]a) T. Nan, H. Lin, Y. Gao, A. Matyushov, G. Yu, H. Chen, N. Sun, S. Wei, Z. Wang, M. Li et al., Nat. Commun. 2017, 8, 296; b) C. Dong, C. Sun, L. Chen, Y. He, Y. Liu, B. Luo, N. X. Sun, Materials Today Electronics 2025, 100135.
  2. [2]a) S. Kopyl, R. Surmenev, M. Surmeneva, Y. Fetisov, A. Kholkin, Materials Today Bio 2021, 12, 100149; b) H. Heidari, Magnetic Sensors for Biomedical Applications, John Wiley & Sons Incorporated, Newark, 2020; c) K. Zhu, A. Kiourti, IEEE Open J. Antennas Propag. 2022, 3, 732.
  3. [3]a) E. Elzenheimer, C. Bald, E. Engelhardt, J. Hoffmann, P. Hayes, J. Arbustini, A. Bahr, E. Quandt, M. Höft, G. Schmidt, Sensors 2022, 22, 1018; b) K. Sternickel, A. I. Braginski, Supercond. Sci. Technol. 2006, 19, S160-S171.
  4. [4]X. Liang, A. Matyushov, P. Hayes, V. Schell, C. Dong, H. Chen, Y. He, A. Will-Cole, E. Quandt, P. Martins et al., IEEE Transactions on Magnetics 2021, 57, 1.
  5. [5]L. Thormählen, P. Hayes, E. Elzenheimer, E. Spetzler, G. Schmidt, M. Höft, J. McCord, D. Meyners, E. Quandt, Appl. Phys. Lett. 2024, 124.
  6. [6]E. Elzenheimer, P. Hayes, L. Thormählen, E. Engelhardt, A. Zaman, E. Quandt, N. Frey, M. Höft, G. Schmidt, IEEE Sensors Journal 2023, 23, 5660.
  7. [7]J. van den Boomgaard, A. M. J. G. van Run, J. V. Suchtelen, Ferroelectrics 1976, 10, 295.
  8. [8]P. Durdaut, S. Salzer, J. Reermann, V. Röbisch, P. Hayes, A. Piorra, D. Meyners, E. Quandt, G. Schmidt, R. Knöchel et al., IEEE Sensors Journal 2017, 17, 2338.
  9. [9]Y. K. Fetisov, G. Srinivasan, Journal of Applied Physics 2024, 135.
  10. [10]E. W. Lee, Rep. Prog. Phys. 1955, 18, 184.
  11. [11]E. Spetzler, B. Spetzler, D. Seidler, J. Arbustini, L. Thormählen, E. Elzenheimer, M. Höft, A. Bahr, D. Meyners, J. McCord, Advanced Sensor Research 2024, 2400109.
  12. [12]a) N. Tiercelin, V. Preobrazhensky, P. Pernod, H. Le Gall, J. Ben Youssef, J. Magn. Magn. Mater. 2000, 210, 302; b) X. Zhuang, M. L. C. Sing, C. Cordier, S. Saez, C. Dolabdjian, L. Shen, J. F. Li, M. Li, D. Viegland, IEEE Sensors Journal 2011, 11, 2266.
  13. [13]B. Spetzler, E. V. Golubeva, R.-M. Friedrich, S. Zabel, C. Kirchhof, D. Meyners, J. McCord, F. Faupel, Sensors 2021, 21, 2022.
  14. [14]Z. Zhang, H. Wu, L. Sang, Y. Takahashi, J. Huang, L. Wang, M. Toda, I. M. Akita, Y. Koide, S. Koizumi et al., ACS applied materials & interfaces 2020, 12, 23155.
  15. [15]S. Zabel, C. Kirchhof, E. Yarar, D. Meyners, E. Quandt, F. Faupel, Appl. Phys. Lett. 2015, 107, 152402.
  16. [16]R. Jahns, S. Zabel, S. Marauska, B. Gojdka, B. Wagner, R. Knöchel, R. Adelung, F. Faupel, Appl. Phys. Lett. 2014, 105.
  17. [17]Z. Chu, C. Dong, C. Tu, X. Liang, H. Chen, C. Sun, Z. Yu, S. Dong, N.-X. Sun, Appl. Phys. Lett. 2019, 115.
  18. [18]M. D. Mermelstein, Electronics Letters 1986, 22, 525.
  19. [19]P. Hayes, M. Jovičević Klug, S. Toxvaerd, P. Durdaut, V. Schell, A. Teplyuk, D. Burdin, A. Winkler, R. Weser, Y. Fetisov et al., Sci Rep 2019, 9, 16355.
  20. [20]J. Schmalz, E. Spetzler, J. McCord, M. Gerken, Sensors 2023, 23, 5012.
  21. [21]B. Spetzler, E. V. Golubeva, C. Müller, J. McCord, F. Faupel, Sensors 2019, 19, 4769.
  22. [22]E. Spetzler, B. Spetzler, J. McCord, Advanced Functional Materials 2023, 34, 2309867.
  23. [23]W. O. Davis, Journal of Microelectromechanical Systems 2011, 20, 968.
  24. [24]A. D. Matyushov, B. Spetzler, M. Zaeimbashi, J. Zhou, Z. Qian, E. V. Golubeva, C. Tu, Y. Guo, B. F. Chen, D. Wang et al., Adv. Mater. Technol. 2021, 6, 21000294.
  25. [25]a) Y. K. Fetisov, D. A. Burdin, N. A. Ekonomov, L. Y. Fetisov, A. A. Berzin, P. Hayes, E. Quandt, Appl. Phys. Lett. 2018, 113; b) Z. Chu, C. Dong, C. Tu, Y. He, X. Liang, J. Wang, Y. Wei, H. Chen, X. Gao, C. Lu et al., Phys. Rev. Appl. 2019, 12, 44001.
  26. [26]a) B. Spetzler, C. Kirchhof, J. Reermann, P. Durdaut, M. Höft, G. Schmidt, E. Quandt, F. F upangel, Appl. Phys. Lett. 2019, 114; b) B. Spetzler, C. Kirchhof, E. Quandt, J. McCord, F. Faupel, Phys. Rev. Appl. 2019, 12, 64036.
  27. [27]R. Jahns, R. Knöchel, H. Greve, E. Woltermann, E. Lage, E. Quandt in 2011 IEEE International Workshop on Medical Measurements and Applications proceedings. (MeMeA 2011) ; Bari, Italy, 30 - 31 May 2011 (Ed.: M. Savino), IEEE, Piscataway, NJ, 2011, pp. 107–110.
  28. [28]A. Ludwig, E. Quandt, IEEE Trans. Magn. 2002, 38, 2829.

Paper details

vlnc:W_rtk46w68
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 0

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents