betaFeedback

WorksPhysics and Astronomy

First observation of the decay Ds1(2460)+→Ds∗+γD_{s1}(2460)^{+} \to D_{s}^{*+}γ and measurement of the branching-fraction ratio B[Ds1(2460)+→Ds∗+γ]/B[Ds1(2460)+→Ds+γ]\mathcal{B}[D_{s1}(2460)^{+} \to D_{s}^{*+} γ]/\mathcal{B}[D_{s1}(2460)^{+} \to D_{s}^{+} γ]

Abstract

We report the first observation of the radiative decay Ds1(2460)+→Ds∗+γD_{s1}(2460)^{+} \to D_{s}^{*+} γ with a significance greater than 10 standard deviations. The signal is found in e+e−→ccˉe^{+}e^{-} \to c\bar{c} production using data samples with integrated luminosities of 980 and 572~fb−1\mathrm{fb}^{-1} collected by the Belle and Belle~II detectors operating at the KEKB and SuperKEKB asymmetric-energy e+e−e^{+}e^{-} colliders, respectively. The branching-fraction ratio B[Ds1(2460)+→Ds∗+γ]/B[Ds1(2460)+→Ds+γ]\mathcal{B}[D_{s1}(2460)^{+} \to D_{s}^{*+} γ]/\mathcal{B}[D_{s1}(2460)^{+} \to D_{s}^{+} γ] is measured to be 0.74±0.05(stat.)±0.06(syst.)0.74 \pm 0.05 ({\rm stat.}) \pm 0.06 ({\rm syst.)}. This result helps discriminate between different theoretical models regarding the internal structure of the charm-strange meson Ds1(2460)+D_{s1}(2460)^{+}.

Exotic hadrons provide sensitive probes of the nonperturbative dynamics of quantum chromodynamics (QCD), shedding light on the formation of color-singlet matter beyond the conventional quark model [1, 2, 3, 4, 5]. The discoveries of the charm-strange mesons Ds0∗(2317)+D_{s0}^{*}(2317)^+ [6] and Ds1(2460)+D_{s1}(2460)^+ [7] have long challenged conventional quark-model expectations, as their masses are lower than the predictions for the corresponding csˉc\bar{s} states with matching spin (JJ) and parity (PP) [8, 9, 10, 11]. Both states are very narrow and lie below the DKDK and D∗KD^*K thresholds, respectively, with their dominant decays proceeding through isospin-violating processes [12]. These properties have motivated various interpretations of their nature, including csˉc\bar{s} mesons [13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24], hadronic molecules [25, 26, 27, 28, 29, 30, 31, 32, 33], compact tetraquark configurations [34, 35, 36, 37], and mixed states [38, 39, 40, 41, 42, 43, 44]. Even after extensive experimental and theoretical efforts [13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48, 49, 50, 51, 52, 53, 54, 55, 56], the internal structure of the Ds0∗(2317)+D_{s0}^{*}(2317)^+ and Ds1(2460)+D_{s1}(2460)^+ mesons remains an open question in charm spectroscopy.

Radiative decays play a distinctive role in elucidating hadron structure, as their electromagnetic transition rates are sensitive to the underlying internal configuration [46, 47, 48]. The radiative decay Ds0∗(2317)+→Ds∗+γD_{s0}^{*}(2317)^+ \to D_s^{*+}\gamma was recently observed for the first time by the Belle and Belle II experiments, providing important constraints on theoretical interpretations of the Ds0∗(2317)+D_{s0}^{*}(2317)^+ structure [49]. The Ds1(2460)+D_{s1}(2460)^+, which has JP=1+J^P = 1^+ [50, 51], can undergo radiative decays to both Ds+γD_s^+\gamma and Ds∗+γD_s^{*+}\gamma. The decay Ds1(2460)+→Ds+γD_{s1}(2460)^+ \to D_s^+\gamma was first observed by Belle [50]. Searches for Ds1(2460)+→Ds∗+γD_{s1}(2460)^+ \to D_s^{*+}\gamma were performed by CLEO [7], Belle [52], and BaBar [53], but no significant signal was observed. The branching-fraction ratio R=B[Ds1(2460)+→Ds∗+γ]/B[Ds1(2460)+→Ds+γ]\mathcal{R} = \mathcal{B}[D_{s1}(2460)^+ \to D_s^{*+}\gamma]/\mathcal{B}[D_{s1}(2460)^+ \to D_s^+\gamma] is expected to be sensitive to the internal structure of the Ds1(2460)+D_{s1}(2460)^+. Existing theoretical calculations provide a wide range of predictions for R\mathcal{R} [13, 14, 15, 16, 17, 18, 19, 31, 32, 33, 45]. Most calculations within the conventional csˉc\bar{s} picture yield values of R\mathcal{R} between approximately 0.35 and 1.33 [13, 14, 15, 16, 17, 18], whereas some calculations based on the D∗KD^*K molecular interpretation predict smaller values, typically around 0.07–0.31 [31, 32]. A measurement of R\mathcal{R} can provide constraints on the internal structure of the Ds1(2460)+D_{s1}(2460)^+ and test competing interpretations of its nature.

The interpretation of the Ds1(2460)+D_{s1}(2460)^+ within the conventional quark-model framework suggests that it can be a mixture of 1P1^1P_1 and 3P1^3P_1 csˉc\bar{s} configurations [18, 33]. Since the radiative decays Ds1(2460)+→Ds∗+γD_{s1}(2460)^+ \to D_s^{*+}\gamma and Ds1(2460)+→Ds+γD_{s1}(2460)^+ \to D_s^+\gamma couple differently to these two components, the value of R\mathcal{R} depends on the underlying mixing angle. For instance, Close and Swanson [33] calculate Γ(Ds1(2460)+→Ds∗+γ)=4.2sin⁡2θs\Gamma(D_{s1}(2460)^+ \to D_s^{*+}\gamma) = 4.2\sin^2\theta_s keV and Γ(Ds1(2460)+→Ds+γ)=7.3cos⁡2θs\Gamma(D_{s1}(2460)^+ \to D_s^+\gamma) = 7.3\cos^2\theta_s keV, giving R=0.58tan⁡2θs\mathcal{R} = 0.58\tan^2\theta_s, where θs\theta_s is the 1P1^1P_1–3P1^3P_1 mixing angle. Thus, a measurement of R\mathcal{R} would help constrain the possible 1P1^1P_1–3P1^3P_1 mixing pattern of Ds1(2460)+D_{s1}(2460)^+.

In this Letter, we report the first observation of the radiative decay Ds1(2460)+→Ds∗+γD_{s1}(2460)^+ \to D_s^{*+}\gamma, with Ds∗+→Ds+γD_s^{*+} \to D_s^+\gamma, in continuum e+e−→ccˉe^+e^- \to c\bar{c} production. The decay Ds1(2460)+→Ds+γD_{s1}(2460)^+ \to D_s^+\gamma is used as the reference channel, and the ratio of the two decay branching fractions, R\mathcal{R}, is measured. The Ds+D_s^+ candidates are reconstructed via the ϕπ+\phi\pi^+ and K+Kˉ∗0K^+\bar{K}^{*0} decay channels, both of which lead to the same K+K−π+K^+K^-\pi^+ final state. Charge-conjugate decays are implicitly included throughout this Letter. This measurement is based on data recorded with the Belle detector at center-of-mass (c.m.) energies ranging from 9.46 to 10.87 GeV [57, 58], and with the Belle II detector from 10.52 to 10.81 GeV [59]. The integrated luminosities are 980 and 572 fb−1^{-1} for Belle and Belle II, respectively.

Data and Monte Carlo (MC) simulated samples for both Belle and Belle II are processed with the Belle II analysis software framework [60, 61]. MC simulated signal events are used to optimize the selection criteria, calculate the detection efficiencies, and determine the fit models. Continuum e+e−→ccˉe^+e^- \to c\bar{c} events are generated using PYTHIA6 [62] for Belle and PYTHIA8 [63] and KKMC [64] for Belle II, where at least one of the charm quarks hadronizes into a Ds1(2460)+D_{s1}(2460)^+ meson for the signal and reference channels. The decay Ds1(2460)+→Ds∗+γD_{s1}(2460)^+ \to D_s^{*+}\gamma is generated with the phase space model, while the decays Ds∗+→Ds+γD_s^{*+} \to D_s^+\gamma and Ds1(2460)+→Ds+γD_{s1}(2460)^+ \to D_s^+\gamma are generated as PP-wave decays. The decay Ds+→K+K−π+D_s^+ \to K^+K^-\pi^+ is modeled based on the previous measurement [65]. The effect of final-state radiation is taken into account in the simulation using the PHOTOS package [66]. Generated signal events undergo detector simulation with GEANT3 [67] for Belle and GEANT4 [68] for Belle II. The signal MC events are reweighted according to the xpx_p distribution measured in the reference channel, where xp≡pDs1(2460)+∗/pmax⁡∗x_p \equiv p^{*}_{D_{s1}(2460)^{+}}/p^{*}_{\max} is the reduced momentum of the selected Ds1(2460)+D_{s1}(2460)^{+} candidate. Here, pDs1(2460)+∗p^{*}_{D_{s1}(2460)^{+}} is its momentum in the e+e−e^{+}e^{-} c.m. frame, and pmax⁡∗≡1cEbeam2−M2[Ds1(2460)+]c4p^{*}_{\max} \equiv\frac{1}{c}\sqrt{E_{\mathrm{beam}}^{2}-M^{2}[D_{s1}(2460)^{+}]c^{4}}, where EbeamE_{\mathrm{beam}} is the beam energy in the e+e−e^{+}e^{-} c.m. frame and M[Ds1(2460)+]M[D_{s1}(2460)^{+}] is the invariant mass of the Ds1(2460)+D_{s1}(2460)^{+} candidate. To study background sources [69] and optimize the selection criteria, inclusive MC samples as described in Ref. [70] are used.

To avoid experimental bias, the signal region in data is not examined until the analysis procedure is finalized. All selection criteria are determined through an iterative optimization of a figure of merit [71] for a target significance of five standard deviations (σ\sigma) for the signal decay Ds1(2460)+→Ds∗+γD_{s1}(2460)^{+} \to D_s^{*+}\gamma, based on simulated samples. We apply identical selection criteria in the Belle and Belle II analyses.

The Ds+D_s^{+} candidates are reconstructed from the K+K−π+K^{+}K^{-}\pi^{+} final state using the same selection criteria as those used in the recent observation of the radiative decay Ds0∗(2317)+→Ds∗+γD_{s0}^{*}(2317)^{+} \to D_s^{*+}\gamma [49]. The candidates are required to be consistent with either the ϕπ+\phi\pi^{+} or K+Kˉ∗0K^{+}\bar{K}^{*0} decay channel. For the K+Kˉ∗0K^{+}\bar{K}^{*0} channel, an additional requirement of ∣cos⁡θh(Kˉ∗0)∣>0.3|\cos\theta_h(\bar{K}^{*0})| > 0.3 is imposed to suppress combinatorial background. Here, θh(Kˉ∗0)\theta_h(\bar{K}^{*0}) is the helicity angle of the Kˉ∗0\bar{K}^{*0} candidate, i.e., the angle between the K−K^{-} momentum and the direction opposite to the Ds+D_s^{+} momentum in the Kˉ∗0\bar{K}^{*0} rest frame. The signal region for the reconstructed Ds+D_s^{+} candidates is defined as ∣Mrec(K+K−π+)−m(Ds+)∣<10 MeV/c2|M^{\mathrm{rec}}(K^{+}K^{-}\pi^{+})-m(D_s^{+})| < 10\ \mathrm{MeV}/c^{2}, corresponding to approximately 2.5 times the mass resolution. Here and throughout the following, Mrec(X)M^{\mathrm{rec}}(X) denotes the reconstructed invariant mass of the system XX. The sidebands are defined as ∣Mrec(K+K−π+)−m(Ds+)±40∣<10 MeV/c2|M^{\mathrm{rec}}(K^{+}K^{-}\pi^{+})-m(D_s^{+})\pm40| < 10\ \mathrm{MeV}/c^{2}, with a total width twice that of the signal region. Here and throughout this paper, m(i)m(i) denotes the known mass of particle ii [12].

Photon candidates are reconstructed following Ref. [49]. Boosted-decision-tree classifiers are used to suppress misreconstructed photons from secondary hadronic interactions and beam-induced background [72]. For the signal channel Ds1(2460)+→Ds∗+(→Ds+γ2)γ1D_{s1}(2460)^{+} \to D_s^{*+}(\to D_s^{+}\gamma_2)\gamma_1, the energies of γ1\gamma_1 and γ2\gamma_2 are required to be greater than 0.50 and 0.14 GeV in the e+e−e^{+}e^{-} c.m. frame, respectively. To suppress background from π0\pi^{0} decays, the invariant mass of the γ1γ2\gamma_1\gamma_2 pair must satisfy ∣Mrec(γ1γ2)−m(π0)∣>15 MeV/c2|M^{\mathrm{rec}}(\gamma_1\gamma_2)-m(\pi^{0})| > 15\ \mathrm{MeV}/c^{2}. The assignments of γ1\gamma_1 and γ2\gamma_2 can be clearly disambiguated, as the Ds+γ1D_s^{+}\gamma_1 combination does not fall within the Ds∗+D_s^{*+} signal region. For the reference channel Ds1(2460)+→Ds+γD_{s1}(2460)^{+} \to D_s^{+}\gamma, the energy of γ\gamma is required to be greater than 0.60 GeV in the e+e−e^{+}e^{-} c.m. frame. For both decay channels, the invariant mass of any combination of a photon emitted directly from the Ds1(2460)+D_{s1}(2460)^{+} decay and other photon candidate in the rest of the event is required to lie outside a 15 MeV/c2c^{2} window around the known π0\pi^{0} mass [12]. This requirement does not apply to the photon from the Ds∗+D_s^{*+} decay, as it reduces the signal efficiency without improving the signal-to-background ratio.

The Ds+D_s^{+} candidates are combined with a photon to form Ds∗+D_s^{*+} candidates. To reduce the uncertainty from the Ds+D_s^{+} mass resolution, we use the modified invariant mass M(Ds+γ2)≡Mrec(K+K−π+γ2)−Mrec(K+K−π+)+m(Ds+)M(D_s^{+}\gamma_2) \equiv M^{\mathrm{rec}}(K^{+}K^{-}\pi^{+}\gamma_2)-M^{\mathrm{rec}}(K^{+}K^{-}\pi^{+})+m(D_s^{+}). This procedure improves the mass resolution by approximately 15%, and a similar improvement is obtained for the reconstructed Ds1(2460)+D_{s1}(2460)^{+} candidates using the analogous modified invariant masses defined below. The signal region for the Ds∗+D_s^{*+} candidates is defined as ∣M(Ds+γ2)−m(Ds∗+)∣<15 MeV/c2|M(D_s^{+}\gamma_2)-m(D_s^{*+})| < 15\ \mathrm{MeV}/c^{2} (approximately 2.5 times the mass resolution), while the sidebands are defined as ∣M(Ds+γ2)−m(Ds∗+)±50∣<15 MeV/c2|M(D_s^{+}\gamma_2)-m(D_s^{*+})\pm50| < 15\ \mathrm{MeV}/c^{2}, with a total width twice that of the signal region.

The Ds∗+γ1D_s^{*+}\gamma_1 and Ds+γD_s^{+}\gamma combinations are used to form Ds1(2460)+D_{s1}(2460)^{+} candidates for the signal and reference channels, respectively. A vertex-fitting algorithm is applied to the entire decay chain, with the requirement that the Ds1(2460)+D_{s1}(2460)^{+} candidate originates from the e+e−e^{+}e^{-} interaction point [73]. To reduce combinatorial backgrounds, the reduced momentum xpx_p is required to be larger than 0.7, which also effectively suppresses Ds1(2460)+D_{s1}(2460)^{+} candidates from BB decays lying in the low-xpx_p region. If multiple Ds1(2460)+D_{s1}(2460)^{+} candidates are found in an event, all combinations are retained for further analysis. The average candidate multiplicities for the signal and reference channels are 1.04 (1.05) and 1.01 (1.01) in Belle (Belle II), respectively. The corresponding multiplicities for all events in the data are consistent with those in the MC simulation.

After applying the aforementioned selection criteria, the M(Ds+γ)M(D_s^{+}\gamma) distributions for the reconstructed Ds1(2460)+→Ds+γD_{s1}(2460)^{+} \to D_s^{+}\gamma candidates in Belle and Belle II data are shown in Figure 1, with the fit results overlaid. Here, M(Ds+γ)M(D_s^{+}\gamma) is defined as Mrec(K+K−π+γ)−Mrec(K+K−π+)+m(Ds+)M^{\mathrm{rec}}(K^{+}K^{-}\pi^{+}\gamma)-M^{\mathrm{rec}}(K^{+}K^{-}\pi^{+})+m(D_s^{+}), which reduces the uncertainty from the Ds+D_s^{+} mass resolution. Backgrounds are studied using both inclusive MC samples and data from the Ds+D_s^{+} sidebands, and no peaking background is found in the M(Ds+γ)M(D_s^{+}\gamma) distributions. Clear Ds1(2460)+→Ds+γD_{s1}(2460)^{+} \to D_s^{+}\gamma signals are observed in Belle and Belle II data samples. The signal yields are extracted separately for the two data samples using unbinned extended maximum-likelihood fits to the M(Ds+γ)M(D_s^{+}\gamma) distributions. In each fit, a double-sided Crystal Ball (CB) function [74] is used as the signal probability density function (PDF), while the combinatorial background PDF is parametrized by a second-order Chebyshev polynomial. All parameters of the signal and combinatorial background PDFs are allowed to float in the fit. The pull distributions, defined as (Ndata−Nfit)/Ndata(N^{\mathrm{data}}-N^{\mathrm{fit}})/\sqrt{N^{\mathrm{data}}}, are also shown in Figure 1, where NdataN^{\mathrm{data}} is the number of events in each bin from data and NfitN^{\mathrm{fit}} is the number of events in each bin according to the fit.

Mass distributions of M(D_s^+\gamma) for Belle and Belle II data

Figure 1. Mass distributions of M(Ds+γ)M(D_s^+\gamma) for the reconstructed Ds1(2460)+→Ds+γD_{s1}(2460)^+ \to D_s^+\gamma candidates with fit projections overlaid in (a) Belle and (b) Belle II data. The data and fit components are indicated in the legends. The sideband distributions are scaled according to the ratio between the defined signal region and sideband of Ds+D_s^+.

The fitted signal yields Nexpfit(Ds+γ)N_{\mathrm{exp}}^{\mathrm{fit}}(D_s^+\gamma) are (3.71±0.19)×103(3.71 \pm0.19) \times10^3 and (3.21±0.18)×103(3.21 \pm0.18) \times10^3 for Belle and Belle II, respectively, and the corresponding detection efficiencies ϵexp(Ds+γ)\epsilon_{\mathrm{exp}}(D_s^+\gamma) are 10.1% and 13.5%. Here and in the following, the subscript “exp” denotes the experiment, Belle or Belle II. Similar fits are performed to the M(Ds+γ)M(D_s^+\gamma) distributions in different xpx_p bins to measure the xpx_p distribution of the Ds1(2460)+D_{s1}(2460)^+ candidate. The obtained efficiency-corrected xpx_p distribution is used to derive an xpx_p-dependent correction to the signal MC simulation.

Figure 2 shows the M(Ds∗+γ)M(D_s^{*+}\gamma) distributions for the reconstructed Ds1(2460)+→Ds∗+γD_{s1}(2460)^+ \to D_s^{*+}\gamma candidates in Belle

and Belle II data. Here, M(Ds∗+γ)M(D_s^{*+}\gamma) is defined as Mrec(Ds+γ1γ2)−Mrec(Ds+γ2)+m(Ds∗+)M^{\mathrm{rec}}(D_s^+\gamma_1\gamma_2) - M^{\mathrm{rec}}(D_s^+\gamma_2) + m(D_s^{*+}), which reduces the uncertainty from the Ds∗+D_s^{*+} mass resolution. Clear Ds1(2460)+→Ds∗+γD_{s1}(2460)^+ \to D_s^{*+}\gamma signal peaks are observed in both data samples, together with a broad enhancement on the low-mass side. Studies of inclusive MC samples show that the enhancement is due to crossfeed from Ds1(2460)+→Ds∗+π0D_{s1}(2460)^+ \to D_s^{*+}\pi^0 decay in which one photon from π0→γγ\pi^0 \to\gamma\gamma is not reconstructed, and that the remaining background is dominated by a smooth combinatorial component. No peaking background is observed in the Ds∗+D_s^{*+} sidebands in either the Belle or Belle II data. Dedicated MC studies also show that other known decay channels of the Ds0∗(2317)+D_{s0}^*(2317)^+ or Ds1(2460)+D_{s1}(2460)^+ do not produce peaking backgrounds in the considered M(Ds∗+γ)M(D_s^{*+}\gamma) region.

To extract the branching-fraction ratio R\mathcal{R}, we perform a simultaneous unbinned extended maximum-likelihood fit to the M(Ds∗+γ)M(D_s^{*+}\gamma) distributions from Belle and Belle II data, using the Ds1(2460)+→Ds+γD_{s1}(2460)^+ \to D_s^+\gamma signal yields and the corresponding reconstruction efficiencies discussed earlier as inputs. The Ds1(2460)+→Ds∗+γD_{s1}(2460)^+ \to D_s^{*+}\gamma signal PDF is described by a double-sided CB function, while the combinatorial background PDF is parametrized by a third-order Chebyshev polynomial with free parameters. The crossfeed contribution from partially reconstructed Ds1(2460)+→Ds∗+π0D_{s1}(2460)^+ \to D_s^{*+}\pi^0 decays is modeled using smoothed MC histograms, with the yields treated as free parameters. For each data sample, the parameters of the signal PDF, except for the mean, are fixed to the values obtained from the corresponding MC simulation. The value of R\mathcal{R} is shared as a common free parameter in the simultaneous fit, while the Ds1(2460)+→Ds∗+γD_{s1}(2460)^+ \to D_s^{*+}\gamma signal yields are set separately for Belle and Belle II according to Nexp(Ds∗+γ)=RNexpfit(Ds+γ)ϵexp(Ds∗+γ)/ϵexp(Ds+γ)N_{\mathrm{exp}}(D_s^{*+}\gamma)=\mathcal{R}N_{\mathrm{exp}}^{\mathrm{fit}}(D_s^+\gamma)\epsilon_{\mathrm{exp}}(D_s^{*+}\gamma)/\epsilon_{\mathrm{exp}}(D_s^+\gamma). Here, ϵexp(Ds∗+γ)\epsilon_{\mathrm{exp}}(D_s^{*+}\gamma) is the detection efficiency of the Ds1(2460)+→Ds∗+γD_{s1}(2460)^+ \to D_s^{*+}\gamma decay, with the branching fraction of Ds∗+→Ds+γD_s^{*+}\to D_s^+\gamma included, which is 3.70% for Belle and 5.42% for Belle II. The fit results are shown in Figure 2 along with the pull distributions. The fitted R\mathcal{R} value is 0.74±0.050.74 \pm0.05 with the statistical uncertainties on Nexpfit(Ds+γ)N_{\mathrm{exp}}^{\mathrm{fit}}(D_s^+\gamma) included, and the corresponding signal yields of Ds1(2460)+→Ds∗+γD_{s1}(2460)^+ \to D_s^{*+}\gamma in Belle and Belle II data are (1.00±0.06)×103(1.00 \pm0.06) \times10^3 and (0.96±0.06)×103(0.96 \pm0.06) \times10^3, respectively. The quoted uncertainties are statistical only.

Mass distributions of M(D_s^{*+}\gamma) for Belle and Belle II data

Figure 2. Mass distributions of M(Ds∗+γ)M(D_s^{*+}\gamma) for the reconstructed Ds1(2460)+→Ds∗+γD_{s1}(2460)^+ \to D_s^{*+}\gamma candidates with fit projections overlaid in (a) Belle and (b) Belle II data. The data and fit components are indicated in the legends. The sideband distributions are scaled according to the ratio between the defined signal region and sideband of Ds∗+D_s^{*+}.

The statistical significance of the Ds1(2460)+→Ds∗+γD_{s1}(2460)^+ \to D_s^{*+}\gamma signal is 16.8σ16.8\sigma, estimated from the negative log-likelihood ratio −2ln⁡(L0/Lmax⁡)=292-2\ln(\mathcal{L}_0/\mathcal{L}_{\max})=292 [75], while accounting for a difference of three degrees of freedom between the two fits. Here, L0\mathcal{L}_0 and Lmax⁡\mathcal{L}_{\max} are the likelihood values obtained from fits without and with the signal component, respectively. After incorporating the systematic uncertainties discussed below, the signal significance remains greater than 10σ10\sigma.

As a consistency check, separate fits are performed to the Belle and Belle II data samples using the same fit model as in the simultaneous fit. The fitted signal yields Nexpfit(Ds∗+γ)N_{\mathrm{exp}}^{\mathrm{fit}}(D_s^{*+}\gamma) are (1.06±0.09)×103(1.06 \pm0.09) \times10^3 and (0.91±0.08)×103(0.91 \pm0.08) \times10^3 for Belle and Belle II, respectively. The corresponding R\mathcal{R} values are 0.79±0.080.79 \pm0.08 and 0.71±0.070.71 \pm0.07, respectively, which are consistent with each other. The quoted uncertainties are statistical only. The efficiency-corrected yields per unit luminosity of the crossfeed component in Belle and Belle II data are consistent within 1σ1\sigma. To further verify our findings, we fully reconstruct the decay Ds1(2460)+→Ds∗+π0D_{s1}(2460)^+ \to D_s^{*+}\pi^0 using Belle data. Comparing the fitted signal yields and the relative reconstruction efficiencies for both the fully reconstructed and crossfeed samples, we find that the crossfeed yield agrees with the expectation within 1σ1\sigma.

The dominant systematic uncertainties in the measurement of R\mathcal{R} arise from the fit model, the photon reconstruction efficiency, the xpx_p reweighting, and the potential Ds1(2460)+D_{s1}(2460)^+ polarization. The systematic uncertainties associated with the Ds+D_s^+ selection cancel in the extraction of R\mathcal{R}.

To estimate the systematic uncertainty associated with the fit model for the reference channel Ds1(2460)+→Ds+γD_{s1}(2460)^+ \to D_s^+\gamma, we repeat the fit with alternative configurations in which the fit range and the order of the background polynomial are varied by ±10\pm10 MeV and ±1\pm1 order, respectively. Based on the fitted signal and background components from each fit alternative, 1000 pseudo-experiments are generated and fitted with the nominal model. The largest difference between the mean fitted signal yield and the corresponding input yield is assigned as the systematic uncertainty on Nexpfit(Ds+γ)N_{\mathrm{exp}}^{\mathrm{fit}}(D_s^+\gamma). The resulting fractional uncertainties are 1.4% and 2.4% for Belle and Belle II, respectively. The reference channel yields are then varied by these amounts in the simultaneous fit to the M(Ds∗+γ)M(D_s^{*+}\gamma) distributions in data, resulting in a 1.9% systematic uncertainty on R\mathcal{R}.

The systematic uncertainty associated with the background shape for the signal channel Ds1(2460)+→Ds∗+γD_{s1}(2460)^+ \to D_s^{*+}\gamma is evaluated using a procedure similar to that for the reference channel, yielding a 6.2% uncertainty on R\mathcal{R}. The uncertainty due to the fit range is estimated by extending the fit range to [2.31,2.60][2.31,2.60] GeV/c2c^2, while keeping the possible Ds1(2536)D_{s1}(2536) signal region blinded. The resulting change in R\mathcal{R}, 2%, is taken as the systematic uncertainty. The data–MC difference in the Ds1(2460)+D_{s1}(2460)^+ signal resolution is evaluated using the reference channel. For each experiment, the M(Ds+γ)M(D_s^+\gamma) distribution in data is fitted using the signal shape obtained from the corresponding signal MC sample, convolved with a Gaussian function whose width is allowed to vary. The fitted Gaussian widths are 2.2 and 2.8 MeV/c2c^2 for Belle and Belle II, respectively. For the signal channel, the simultaneous fit to the Belle and Belle II data is repeated with the signal PDF convolved with a Gaussian function whose width is fixed to the value determined from the reference channel for each experiment, resulting in a 1.1% systematic uncertainty on R\mathcal{R}. The crossfeed shape is varied by changing the smoothing of the MC histogram, shifting its shape according to the data–MC difference in the Ds1(2460)+D_{s1}(2460)^+ signal peak position, and convolving it with an additional Gaussian resolution function whose width is fixed to the data–MC difference in the mass resolution determined from the reference channel. The resulting changes in R\mathcal{R} are negligible.

The photon reconstruction efficiency is calibrated using radiative Bhabha events for Belle and radiative muon-pair and τ→π/Kντπ0\tau\to\pi/K\nu_\tau\pi^0 control samples for Belle II. The systematic uncertainties in the photon reconstruction efficiency are expected to be linearly correlated between the signal and reference channels, and therefore cancel in the overlapping photon momentum and polar-angle regions. The residual systematic uncertainties from the non-overlapping regions on the signal-to-reference efficiency ratio, ϵexp(Ds∗+γ)/ϵexp(Ds+γ)\epsilon_{\mathrm{exp}}(D_s^{*+}\gamma)/\epsilon_{\mathrm{exp}}(D_s^+\gamma), are 4.2% and 3.8% for Belle and Belle II, respectively. The efficiency ratios are varied within these uncertainties in the simultaneous fit to data. The resulting variation in R\mathcal{R} is 4.1%.

The systematic uncertainty due to the xpx_p reweighting is evaluated by varying the polynomial order used to fit the efficiency-corrected xpx_p distribution by ±1\pm1 around the nominal fourth-order choice. The signal MC samples are reweighted accordingly, and the resulting efficiencies are used in the simultaneous fit. The resulting variation in R\mathcal{R} is 0.9%, which is assigned as the corresponding systematic uncertainty.

The systematic uncertainty associated with the potential Ds1(2460)+D_{s1}(2460)^+ polarization is evaluated using the efficiency-corrected cos⁡θh\cos\theta_h distributions in data, where θh\theta_h is the angle between the momentum of the e+e−e^+e^- system and that of the photon in the Ds1(2460)+D_{s1}(2460)^+ rest frame. The signal MC events for the reference and signal channels are reweighted using the efficiency-corrected cos⁡θh\cos\theta_h distributions obtained from data for the corresponding channels, and the resulting efficiencies are used in the simultaneous fit. The resulting variation in R\mathcal{R} is 0.9%.

Assuming all systematic uncertainties are independent, they are added in quadrature, resulting in a total systematic uncertainty of 8.1%.

In summary, using data samples corresponding to integrated luminosities of 980 and 572 fb−1^{-1} collected with the Belle and Belle II detectors, respectively, we report the first observation of the radiative decay Ds1(2460)+→Ds∗+γD_{s1}(2460)^+ \to D_s^{*+}\gamma. Taking the decay Ds1(2460)+→Ds+γD_{s1}(2460)^+ \to D_s^+\gamma as the reference channel, the branching-fraction ratio R=B[Ds1(2460)+→Ds∗+γ]/B[Ds1(2460)+→Ds+γ]\mathcal{R} = \mathcal{B}[D_{s1}(2460)^+ \to D_s^{*+}\gamma]/\mathcal{B}[D_{s1}(2460)^+ \to D_s^+\gamma] is measured to be 0.74±0.05(stat.)±0.06(syst.)0.74 \pm0.05(\mathrm{stat.}) \pm0.06(\mathrm{syst.}). Using the branching fraction B[Ds1(2460)+→Ds+γ]=(18±4)%\mathcal{B}[D_{s1}(2460)^+ \to D_s^+\gamma] = (18\pm4)\% [12], we obtain the absolute branching fraction B[Ds1(2460)+→Ds∗+γ]=[13±1  (stat.)±1  (syst.)±3  (ext.)]%\mathcal{B}[D_{s1}(2460)^+ \to D_s^{*+}\gamma] = [13 \pm1\;(\mathrm{stat.}) \pm1\;(\mathrm{syst.}) \pm3\;(\mathrm{ext.})]\%, where the last uncertainty is due to the uncertainty in B[Ds1(2460)+→Ds+γ]\mathcal{B}[D_{s1}(2460)^+ \to D_s^+\gamma]. The measured branching fraction is approximately 2.8σ2.8\sigma above the upper limit of 8% established by the Particle Data Group at 90% confidence level, after accounting for the correlated normalization uncertainty. Similarly, the measured R\mathcal{R} value differs from the CLEO [7] and BaBar [53] measurements by 2.3σ2.3\sigma and 2.1σ2.1\sigma, respectively.

Figure 3 compares the measured R\mathcal{R} value with various theoretical predictions for different descriptions of the Ds1(2460)+D_{s1}(2460)^+ state [13, 14, 15, 16, 17, 18, 19, 31, 32, 33, 45]. The predictions show strong model dependence, spanning a wide range even for the same assumed internal structure. Our measurement provides new constraints on these theoretical descriptions and new experimental input for understanding the internal structure of the Ds1(2460)+D_{s1}(2460)^+ meson. Within a conventional csˉc\bar{s} interpretation, the measured R\mathcal{R} value also constrains the 1P1{}^{1}P_1–3P1{}^{3}P_1 mixing in the Ds1(2460)+D_{s1}(2460)^+ state. For example, in the quark-model framework from Ref. [33], it corresponds to a mixing angle of ∣θs∣=[48.4−1.0+0.9  (stat.)−1.2+1.1  (syst.)]∘|\theta_s| = [48.4^{+0.9}_{-1.0}\;(\mathrm{stat.})^{+1.1}_{-1.2}\;(\mathrm{syst.})]^\circ, where only

Comparison of the measured $\mathcal{R}$ value with various theoretical predictions

Figure 3. Comparison of the measured R\mathcal{R} value with various theoretical predictions. For a conventional csˉc\bar{s} interpretation of the Ds1(2460)+D_{s1}(2460)^+, the predictions are obtained from quark models by Godfrey [13], Green [16], and Radford [17]; heavy-light chiral effective theory by Bardeen [14]; heavy-quark effective theory combined with chiral perturbation theory by Ferrandes [15]; a treatment of 1P1{}^{1}P_1–3P1{}^{3}P_1 mixing by Bondar [18]; and light-cone QCD sum rules by Colangelo [19], with the shown R\mathcal{R} range inferred from the quoted radiative-width ranges. Predictions beyond the conventional csˉc\bar{s} picture include a D∗KD^*K molecular description within effective field theory by Fu [31]; D∗KD^*K molecular and mixed D∗KD^*K configurations in an unquenched quark model by Zhang [32]; a D∗KD^*K molecular scenario considered by Close [33]; and a dynamically generated D∗KD^*K–Ds∗ηD_s^*\eta state within a chiral coupled-channel framework by Lutz [45]. For each of the two configurations considered by Zhang [32], the three predicted values correspond to the cutoff parameter Λ0=0.5\Lambda_0 = 0.5, 1.0, and 1.5 GeV. For Lutz [45], the two predicted values arise from the two possible sign choices of the electromagnetic coupling eAe_A governing light-vector-meson radiative transitions.

the experimental uncertainties are included.

This work, based on data collected using the Belle II detector, which was built and commissioned prior to March 2019, and data collected using the Belle detector, which was operated until June 2010, was supported by Higher Education and Science Committee of the Republic of Armenia Grant No. 23LCG-1; Australian Research Council and Research Grants No. DP200101792, No. DP210101900, No. DP210102831, No. DE220100462, No. LE210100098, and No. LE230100085; Austrian Federal Ministry of Education, Science and Research, Austrian Science Fund (FWF) Grants DOI: 10.55776/P34529, DOI: 10.55776/J4731, DOI: 10.55776/J4625, DOI: 10.55776/M3153, and DOI: 10.55776/PAT1836324, and Horizon 2020 ERC Starting Grant No. 947006 “InterLeptons”; Natural Sciences and Engineering Research Council of Canada, Digital Research Alliance of Canada, and Canada Foundation for Innovation; National Key R&D Program of China under Contract No. 2024YFA1610503, and No. 2024YFA1610504 National Natural Science Foundation of China and Research Grants No. 11575017, No. 11761141009, No. 11705209, No. 11975076, No. 12135005, No. 12150004, No. 12161141008, No. 12405099, No. 12475093, and No. 12175041, and Shandong Provincial Natural Science Foundation Project ZR2022JQ02; the Czech Science Foundation Grant No. 22-18469S, Regional funds of EU/MEYS: OPJAK FORTE CZ.02.01.01/00/22 008/0004632 and Charles University Grant Agency project No. 246122; European Research Council, Seventh Framework PIEF-GA-2013-622527, Horizon 2020 ERC-Advanced Grants No. 267104 and No. 884719, Horizon 2020 ERC-Consolidator Grant No. 819127, Horizon 2020 Marie Sklodowska-Curie Grant Agreement No. 700525 “NIOBE” and No. 101026516, and Horizon Europe Marie Sklodowska-Curie Staff Exchange project JENNIFER3 Grant Agreement No. 101183137 (European grants); L’Institut National de Physique Nucléaire et de Physique des Particules (IN2P3) du CNRS under Project Identification No. CNRS-IN2P3-14-PP-033 and L’Agence Nationale de la Recherche (ANR) under Grant No. ANR-23-CE31-0018 and ANR-25-CE31-1333 (France); BMFTR, DFG, HGF, MPG, and AvH Foundation (Germany); Department of Atomic Energy under Project Identification No. RTI 4002, Department of Science and Technology, and UPES SEED funding programs No. UPES/R&D-SEED-INFRA/17052023/01 and No. UPES/R&D-SOE/20062022/06 (India); Israel Science Foundation Grant No. 2476/17, U.S.-Israel Binational Science Foundation Grant No. 2016113, and Israel Ministry of Science Grant No. 3-16543; Istituto Nazionale di Fisica Nucleare and the Research Grants BELLE2, and the ICSC – Centro Nazionale di Ricerca in High Performance Computing, Big Data and Quantum Computing, funded by European Union – NextGenerationEU; Japan Society for the Promotion of Science, Grant-in-Aid for Scientific Research Grants No. 16H03993, No. 16H06492, No. 16K05323, No. 17H01133, No. 17H05405, No. 18K03621, No. 18H03710, No. 18H05226, No. 19H00682, No. 20H05850, No. 20H05858, No. 22H00144, No. 22K14056, No. 22K21347, No. 23H05433, No. 26220706, No. 26400255, and No. 26H02056, and the Ministry of Education, Culture, Sports, Science, and Technology (MEXT) of Japan; National Research Foundation (NRF) of Korea Grants No. 2021R1F1A1064008, No. 2022R1A2C1003993, No. RS-2018-NR031074, No. RS-2021-NR060129, No. RS-2024-00354342, No. RS-2025-02219521, No. RS-2026-25471491, No. RS-2026-25480677, and No. RS-2026-25486791, Radiation Science Research Institute, Foreign Large-Size Research Facility Application Supporting project, the Global Science Experimental Data Hub Center, the Korea Institute of Science and Technology Information (K26L1M2C3) and KREONET/GLORIAD; Universiti Malaya RU grant, Akademi Sains Malaysia, and Ministry of Education Malaysia; Frontiers of Science Program Contracts No. FOINS-296, No. CB-221329, No. CB-236394, No. CB-254409, and No. CB-180023, and SEP-CINVESTAV Research Grant No. 237 (Mexico); the Polish Ministry of Science and Higher Education and the National Science Center; the Ministry of Science and Higher Education of the Russian Federation and the HSE University Basic Research Program, Moscow; University of Tabuk Research Grants No. S-0256-1438 and No. S-0280-1439 (Saudi Arabia); Slovenian Research Agency and Research Grants No. J1-50010 and No. P1-0135; Basque Government through grant IT1977-26, Ikerbasque, Basque Foundation for Science, State Agency for Research of the Spanish Ministry of Science, Innovation and Universities (MICIU/AEI) through Grants No. PID2022-136510NB-C33, PID2025-174203NB-I00, and the Severo Ochoa project CEX2023-001292-S, State Secretariat for Telecommunications and Digital Infrastructure with reference TSI-069100-2023-0012, Spain; The Knut and Alice Wallenberg Foundation (Sweden), Contracts No. 2021.0174, No. 2021.0299, and No. 2023.0315; National Science and Technology Council, and Ministry of Education (Taiwan); Thailand Center of Excellence in Physics; TUBITAK ULAKBIM (Turkey); National Research Foundation of Ukraine, Project No. 2020.02/0257, and Ministry of Education and Science of Ukraine; the U.S. National Science Foundation and Research Grants No. PHY-1913789 and No. PHY-2111604, and the U.S. Department of Energy and Research Awards No. DE-AC06-76RLO1830, No. DE-SC0007983, No. DE-SC0009824, No. DE-SC0009973, No. DE-SC0010007, No. DE-SC0001073, No. DE-SC0010118, No. DE-SC0010504, No. DE-SC0011784, No. DE-SC0012704, No. DE-SC0019230, No. DE-SC0026613, No. DE-SC0026215, No. DE-SC0022350, No. DE-SC0023470; and the Vietnam Academy of Science and Technology (VAST) under Grant No. DL0000.05/26-27.

These acknowledgements are not to be interpreted as an endorsement of any statement made by any of our institutes, funding agencies, governments, or their representatives.

We thank the SuperKEKB team for delivering high-luminosity collisions; the KEK cryogenics group for the efficient operation of the detector solenoid magnet and Belle on site; the KEK Computing Research Center for on-site computing support; the NII for SNET6 network support; and the raw-data centers hosted by BNL, DESY, GridKa, IN2P3, INFN, and the University of Victoria.

Data availability — The full Belle II data are not publicly available. The collaboration will consider requests for access to the data that support this article.

References

References

  1. [1]S. L. Olsen, T. Skwarnicki, and D. Zieminska, Rev. Mod. Phys. 90, 015003 (2018).
  2. [2]F. K. Guo, C. Han hart, U. G. Meißner, Q. Wang, Q. Zhao, and B. S. Zou, Rev. Mod. Phys. 90, 015004 (2018) [erratum: Rev. Mod. Phys. 94, 029901 (2022)].
  3. [3]N. Brambilla, S. Eidelman, C. Han hart, A. Nefediev, C. P. Shen, C. E. Thomas, A. Vairo, and C. Z. Yuan, Phys. Rept. 873, 1 (2020).
  4. [4]H. X. Chen, W. Chen, X. Liu, Y. R. Liu, and S. L. Zhu, Rept. Prog. Phys. 86, 026201 (2023).
  5. [5]X. Dai, S. Jia, A. Nefediev, J. Nieves, C. P. Shen, and L. M. Zhang, Phys. Rept. 1191, 1 (2026).
  6. [6]B. Aubert et al. (BaBar Collaboration), Phys. Rev. Lett. 90, 242001 (2003).
  7. [7]D. Besson et al. (CLEO Collaboration), Phys. Rev. D 68, 032002 (2003) [erratum: Phys. Rev. D 75, 119908 (2007)].
  8. [8]S. Godfrey and N. Isgur, Phys. Rev. D 32, 189 (1985).
  9. [9]S. Godfrey and R. Kokoski, Phys. Rev. D 43, 1679 (1991).
  10. [10]M. Di Pierro and E. Eichten, Phys. Rev. D 64, 114004 (2001).
  11. [11]D. Ebert, R. N. Faustov, and V. O. Galkin, Eur. Phys. J. C 66, 197 (2010).
  12. [12]F. Takahashi et al. (Particle Data Group), Int. J. Mod. Phys. A 41, 2630011 (2026).
  13. [13]S. Godfrey, Phys. Lett. B 568, 254 (2003).
  14. [14]W. A. Bardeen, E. J. Eichten, and C. T. Hill, Phys. Rev. D 68, 054024 (2003).
  15. [15]R. Ferrandes, arXiv:hep-ph/0407212.
  16. [16]N. Green, W. W. Repko, and S. F. Radford, Nucl. Phys. A 958, 71 (2017).
  17. [17]S. F. Radford, W. W. Repko, and M. J. Saelim, Phys. Rev. D 80, 034012 (2009).
  18. [18]A. E. Bondar and A. I. Milstein, Phys. Rev. D 111, 114019 (2025).
  19. [19]P. Colangelo, F. De Fazio, and A. Ozpineci, Phys. Rev. D 72, 074004 (2005).
  20. [20]Fayyazuddin and Riazuddin, Phys. Rev. D 69, 114008 (2004).
  21. [21]Q. T. Song, D. Y. Chen, X. Liu, and T. Matsuki, Phys. Rev. D 91, 054031 (2015).
  22. [22]W. Wei, P. Z. Huang, and S. L. Zhu, Phys. Rev. D 73, 034004 (2006).
  23. [23]S. Godfrey and K. Moats, Phys. Rev. D 93, 034035 (2016).
  24. [24]S. F. Chen, J. Liu, H. Q. Zhou, and D. Y. Chen, Eur. Phys. J. C 80, 290 (2020).
  25. [25]T. Barnes, F. E. Close, and H. J. Lipkin, Phys. Rev. D 68, 054006 (2003).
  26. [26]E. E. Kolomeitsev and M. F. M. Lutz, Phys. Lett. B 582, 39 (2004).
  27. [27]F. K. Guo, P. N. Shen, H. C. Chiang, R. G. Ping, and B. S. Zou, Phys. Lett. B 641, 278 (2006).
  28. [28]Y. J. Zhang, H. C. Chiang, P. N. Shen, and B. S. Zou, Phys. Rev. D 74, 014013 (2006).
  29. [29]J. L. Rosner, Phys. Rev. D 74, 076006 (2006).
  30. [30]A. Faessler, T. Gutsche, V. E. Lyubovitskij, and
  31. [31]H. L. Fu, H. W. Grißhammer, F. K. Guo, C. Hanhart, and U. G. Meißner, Eur. Phys. J. A 58, 70 (2022).
  32. [32]Z. L. Zhang, Z. W. Liu, S. Q. Luo, P. Chen, and Z. H. Guo, Phys. Rev. D 110, 094037 (2024).
  33. [33]F. E. Close and E. S. Swanson, Phys. Rev. D 72, 094004 (2005).
  34. [34]H. Y. Cheng and W. S. Hou, Phys. Lett. B 566, 193 (2003).
  35. [35]Y. Q. Chen and X. Q. Li, Phys. Rev. Lett. 93, 232001 (2004).
  36. [36]H. Kim and Y. Oh, Phys. Rev. D 72, 074012 (2005).
  37. [37]Z. Y. Chen, Z. H. Cao, Y. Y. Lin, J. Y. Wang, and A. Zhang, arXiv:2602.11744.
  38. [38]A. Martínez Torres, E. Oset, S. Prelovsek, and A. Ramos, JHEP 05, 153 (2015).
  39. [39]J. Song, L. R. Dai, and E. Oset, Eur. Phys. J. A 58, 133 (2022).
  40. [40]J. J. Yang, W. Hao, X. Wang, D. M. Li, Y. X. Li, and E. Wang, Eur. Phys. J. C 83, 1098 (2023).
  41. [41]F. Gil-Domínguez and R. Molina, Phys. Rev. D 109, 096002 (2024).
  42. [42]L. L. Wang, X. M. Zhao, X. H. Liu, and M. J. Yan, Phys. Lett. B 873, 140164 (2026).
  43. [43]M. Albaladejo, P. Fernandez-Soler, J. Nieves, and P. G. Ortega, Eur. Phys. J. C 78, 722 (2018).
  44. [44]Z. Yang, G. J. Wang, J. J. Wu, M. Oka, and S. L. Zhu, Phys. Rev. Lett. 128, 112001 (2022).
  45. [45]M. F. M. Lutz and M. Soyeur, Nucl. Phys. A 813, 14 (2008).
  46. [46]F. K. Guo, C. Hanhart, and A. Nefediev, Particles 9, 46 (2026).
  47. [47]H. L. Fu, F. K. Guo, C. Hanhart, and A. Nefediev, Phys. Rev. D 113, 074026 (2026).
  48. [48]T. M. Aliev, S. Bilmis, and M. Savci, arXiv:2608.25843.
  49. [49]M. Abumusabuh et al. (Belle and Belle II Collaborations), Phys. Rev. Lett. 136, 241901 (2026).
  50. [50]P. Krokovny et al. (Belle Collaboration), Phys. Rev. Lett. 91, 262002 (2003).
  51. [51]B. Aubert et al. (BaBar Collaboration), Phys. Rev. Lett. 93, 181801 (2004).
  52. [52]Y. Mikami et al. (Belle Collaboration), Phys. Rev. Lett. 92, 012002 (2004).
  53. [53]B. Aubert et al. (BaBar Collaboration), Phys. Rev. D 74, 032007 (2006).
  54. [54]B. Aubert et al. (BaBar Collaboration), Phys. Rev. D 74, 031103 (2006).
  55. [55]M. Ablikim et al. (BESIII Collaboration), Phys. Rev. D 97, 051103 (2018).
  56. [56]R. Aaij et al. (LHCb Collaboration), Sci. Bull. 70, 1432 (2025).
  57. [57]A. Abashian et al. (Belle Collaboration), Nucl. Instrum. Meth. A 479, 117 (2002).
  58. [58]J. Brodzicka et al. (Belle Collaboration), Prog. Theor. Exp. Phys. 2012, 04D001 (2012).
  59. [59]T. Abe et al. (Belle II Collaboration), arXiv:1011.0352.
  60. [60]T. Kuhr, C. Pulvermacher, M. Ritter, T. Hauth, and N. Braun (Belle II Framework Software Group), Comput. Softw. Big Sci. 3, 1 (2019).
  61. [61]M. Gelb et al., Comput. Softw. Big Sci. 2, 9 (2018).
  62. [62]T. Sjöstrand, S. Mrenna, and P. Z. Skands, JHEP 05, 026 (2006).
  63. [63]T. Sjöstrand et al., Comput. Phys. Commun. 191, 159 (2015).
  64. [64]S. Jadach, B. F. L. Ward, and Z. Was, Comput. Phys. Commun. 130, 260 (2000).
  65. [65]M. Ablikim et al. (BESIII Collaboration), Phys. Rev. D 104, 012016 (2021).
  66. [66]E. Barberio, B. van Eijk, and Z. Was, Comput. Phys. Commun. 66, 115 (1991).
  67. [67]R. Brun et al., GEANT3: user's guide Geant 3.10, Geant 3.11, CERN Report No. DD/EE/84-1, 1984.
  68. [68]S. Agostinelli et al. (GEANT4 Collaboration), Nucl. Instrum. Meth. A 506, 250 (2003).
  69. [69]X. Y. Zhou, S. X. Du, G. Li, and C. P. Shen, Comput. Phys. Commun. 258, 107540 (2021).
  70. [70]I. Adachi et al. (Belle and Belle II Collaborations), JHEP 03, 061 (2025).
  71. [71]G. Punzi, Conf C030908, MODT002 (2003).
  72. [72]P. Cheema, EPJ Web Conf. 295, 09035 (2024).
  73. [73]J. F. Krohn et al. (Belle II analysis software Group), Nucl. Instrum. Meth. A 976, 164269 (2020).
  74. [74]S. Das, arXiv:1603.08591.
  75. [75]S. S. Wilks, Annals Math. Statist. 9, 60 (1938).

Paper details

vlnc:W_seddaf5s
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 0

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents