betaFeedback

WorksComputer Science

Matching two-dimensional statistics does not certify three-dimensional transport in battery electrodes

Abstract

Three-dimensional battery electrode structures reconstructed from two-dimensional micrographs are routinely used to predict transport, assuming that matching the measured 2D statistics reproduces the relevant 3D properties. We test this premise on X-ray tomograms of three all-solid-state cathodes. With a differentiable conductivity solver, we optimise voxel structures that match the real electrode in phase fractions, boundary density, two- and three-point correlations and lineal-path functions, on all section planes, slab by slab and layer by layer, within measurement noise. Every sample has statistical twins conducting 10-88-fold less than the real electrode, robust to 5^3 majority filtering, whereas the most conductive are at most 3.3-fold above it. The twins rearrange rather than remove material, severing or funnelling through-plane paths. A classifier on 2D sections detects them, as it does current 2D-to-3D generators: the information is in the images but not in the statistics. Matching standard 2D statistics therefore does not certify 3D transport.

Paper details

vlnc:W_ssdtsbem
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
arXiv nonexclusive license
Usage

views · 0

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Computer Science

Claude

View statement