WorksComputer Science
REFORM-3D: A Representation-Centric Evaluation Framework for 3D Medical Vision Foundation Models
Abstract
Evaluation of 3D medical foundation models is typically dominated by downstream task scores, which entangle representation quality with adaptation choices. This is especially critical in volumetric imaging, where spacing and anisotropy can substantially alter image statistics while the anatomy itself remains unchanged. We therefore introduce REFORM-3D, a Representation-centric Evaluation FramewORk for benchmarking frozen 3D medical vision foundation Models across three questions: Acquisition Robustness, asking whether features remain stable when spacing varies while anatomy is fixed; Cross-Modal Anatomical Alignment, asking whether labeled anatomical structures remain recoverable across modalities under balanced bidirectional retrieval; and Anatomical Transfer, asking whether organ identity remains recoverable from limited labeled support under case-disjoint evaluation. These are also pretraining questions, because what a 3D encoder learns depends on how volumes are geometrically presented during self-supervised pretraining. We further introduce Med3DINO encoder family, pretrained on K unlabeled MR, CT, PET, CTA, and CBCT volumes under three explicit geometric assumptions: isotropic normalization, voxel-relative sampling, and spacing-aware resampling. Across Med3DINO and heterogeneous external encoders, REFORM-3D reveals module-specific strengths rather than a single model ordering. Within the controlled Med3DINO comparison, voxel-relative sampling yields lower embedding drift, whereas spacing-aware resampling favors anatomical transfer; semantic-transfer advantages depend on the dataset and feature type. Project link: \href{https://endarzboy.github.io/reform3d-website/}{\highlightLR{REFORM-3D}}.
Introduction
Evaluation of 3D medical vision foundation models is still dominated by downstream task scores [1, 2, 3, 4]. Those scores are useful for showing whether a pretrained encoder can be adapted to a particular segmentation, classification, or retrieval pipeline, but they provide limited evidence about what the frozen representation itself encodes. End-task performance depends not only on pretrained features but also on decoder design, optimization choices, supervision level, and dataset split. As a result, a model can appear strong after adaptation without clarifying whether its features are organized by anatomy or rely on narrower cues that happen to be predictive under a particular evaluation protocol.
This limitation is especially critical in 3D medical imaging because acquisition geometry directly changes the evidence presented to a volumetric encoder [5, 6]. Voxel spacing, through-plane anisotropy, sampling density, and anatomical coverage can all alter how the same organ appears, even when the underlying anatomy is unchanged. Figure 1 isolates this effect through a controlled same-scan perturbation: a single CT volume is resampled to multiple spacings while the anatomical structure is held fixed. The figure reports three complementary probes: cosine drift measures how

Figure 1. Controlled same-scan spacing perturbation under increasing through-plane anisotropy. A single CT volume is resampled from reference isotropic spacing (1.0×1.0×1.0 mm) to moderate (1.0×1.0×3.0 mm) and higher-anisotropy (1.0×1.0×5.0 mm) variants (top). Bottom: VoCo [8] and Med3DINO are compared using (a) cosine embedding drift, (b) feature-space similarity measured by CKA, and (c) cross-spacing semantic transfer, respectively probing embedding movement, preservation of feature-space organization, and semantic transfer under spacing change.
Preprint. far same-scan embeddings move after resampling, CKA [7] measures whether the feature-space organization is preserved, and transfer measures whether the semantic structure remains usable across spacing variants.
This setting reveals a gap that downstream evaluation obscures. Compared with Med3DINO-SA, VoCo [8] exhibits lower cosine drift but weaker preservation of feature-space organization and cross-spacing semantic transfer as anisotropy increases. Low drift alone therefore does not establish robustness: feature organization and label-relevant information must also remain usable. This motivates REFORM-3D to evaluate these properties directly in frozen representations.
To this end, we propose REFORM-3D, a representation-centric evaluation framework for benchmarking frozen representations under controlled variations in acquisition, modality, and anatomy. The framework is organized into three primary modules: Acquisition Robustness, which tests whether frozen features remain stable as spacing and anisotropy vary for the same scan; Cross-Modal Anatomical Alignment, which tests whether labeled structures remain recoverable across modalities under balanced bidirectional retrieval; and Anatomical Transfer, which tests whether organ identity remains recoverable from limited labeled support under case-disjoint evaluation. Collectively, these modules integrate acquisition sensitivity with semantic and anatomical recoverability into an evidence-based pre-adaptation profile that informs data coverage, geometric pretraining, encoder selection, and targeted downstream validation. Each module uses evidence suited to its representation question, and each claim is scoped to its corresponding evaluation surface, defined as the dataset–task–protocol combination.
We further introduce Med3DINO encoders, pretrained on 62,638 (hereafter 62.6K) unlabeled multimodal 3D volumes under three explicit geometric assumptions: isotropic normalization, voxel-relative sampling, and spacing-aware resampling while holding all other pretraining settings fixed. REFORM-3D reveals lower embedding drift under voxel-relative sampling and stronger anatomical recoverability under spacing-aware resampling, while semantic-transfer advantages depend on the dataset and feature type. Applying the same framework to existing 3D medical encoders reveals distinct strengths across the three modules, showing that representation quality is property-specific rather than reducible to a single model ordering. Our contributions are listed as follows:
We introduce REFORM-3D, a representation-centric framework that evaluates frozen 3D medical encoders through Acquisition Robustness, Cross-Modal Anatomical Alignment, and Anatomical Transfer.
We introduce Med3DINO, a family of 3D encoders pretrained on 62.6K unlabeled multi-modal volumes, including MR, CT, PET, CTA, and CBCT, under three geometric assumptions while other pretraining settings remain fixed.
We benchmark Med3DINO alongside existing 3D medical encoders and find that these models exhibit different strengths in representation stability and semantic or anatomical recoverability.
Across heterogeneous datasets and modalities, REFORM-3D evaluates frozen representations under acquisition variation, cross-modal retrieval, and case-disjoint anatomical transfer, providing a reusable basis for studying representation quality beyond downstream scores.
Related Work
Self-supervised Medical Vision Foundation Models: Self-supervised representation learning in natural images has evolved from contrastive methods such as SimCLR [9] and MoCo [10] to DINO [11, 12, 13] pretraining, whose teacher-student formulation has become especially effective for learning dense and local features. This paradigm has since been adapted to medical imaging in both 2D and 3D. In 2D medical imaging, MedDINOv3 [3], Radio-DINO [14], and RAD-DINO [4] demonstrate transferable encoders from DINO-family pretraining on medical images, while DINOv2-based adaptation of ALPNet [2] supports few-shot medical image segmentation. In 3D imaging, BrainIAC [15] builds a brain MR foundation model under contrastive self-supervision, while OpenMind [16] benchmarks large-scale 3D brain MR self-supervised methods, including SimCLR [9] and VoCo [8]. 3DINO [1] more directly adapts DINOv2 [12] to volumetric multimodal pretraining, moving the field toward generalist 3D medical encoders. Recent volumetric encoders further span segmentation-oriented transformers and masked-modeling methods with ViT, Mamba, and hybrid architectures, including SAM-Med3D [17], Hi-End-MAE [18], MambaMIM [19], MiM [20], and GL-MAE [21]. This trajectory also makes clear the need for heterogeneous large-scale pretraining across modalities, anatomical regions, and pathologies if the goal is a general-purpose 3D encoder instead of one confined to a narrow modality or anatomical scope. Nevertheless, these works mainly aim to build stronger encoders through pretraining objectives, architectural adaptation, and scale, while giving much less attention to how frozen features should be evaluated after pretraining. Representation quality is therefore still judged mainly through downstream transfer, not through direct evaluation of what the frozen embedding encodes. This gap is especially relevant for DINO encoders because downstream scores alone do not fully characterize their dense and local features, particularly in 3D imaging, where acquisition geometry changes how the same anatomy is presented. Existing benchmarks address medical vision-language performance [22, 23] and fairness across foundation models [24]. Our focus is acquisition sensitivity and anatomical recoverability in frozen 3D representations.
Medical Foundation Model Benchmarks: There have been several efforts to benchmark medical foundation models across tasks, datasets, fairness criteria, and deployment-oriented settings [22, 24, 23, 25]. Many of these efforts focus on medical Vision-Language Models (VLMs) [22, 23, 25], while FairMedFM also evaluates vision-only models [24]. BrainIAC [15] and OpenMind [16] emphasize predominantly brain-MRI pretraining. These works have made model comparison more systematic through shared task definitions, evaluation protocols, and reporting conventions. REFORM-3D complements these benchmarks by jointly evaluating acquisition sensitivity, cross-modal anatomical alignment, and case-disjoint anatomical transfer in frozen 3D encoders. In 3D medical imaging, that distinction matters because acquisition geometry changes how the same anatomy is presented to the encoder.
Downstream Robustness vs. Representation Evaluation: In 3D medical imaging, anisotropy-aware and cross-slice modeling show that acquisition geometry affects the evidence presented to a volumetric model [5, 6, 26, 27]. When spacing or slice thickness changes, through-plane resolution and cross-slice continuity also change, so the same organ is no longer presented under the same evidence. Existing studies usually examine acquisition variation after task-specific adaptation. That indicates anisotropy matters, but it does not determine whether sensitivity originates in the frozen representation itself or in the adapted task pipeline built on top of it. Our framework evaluates this distinction by examining frozen 3D features through stability under acquisition variation, retrieval of labeled structures across modalities, and case-disjoint anatomical transfer.
The REFORM-3D Framework
The goal of REFORM-3D is to evaluate what frozen 3D representations encode, rather than how well they perform after adaptation. In 3D medical imaging, acquisition variability, modality differences, and anatomical diversity can introduce shortcut features that are not anatomically grounded. Hence, REFORM-3D evaluates frozen representations through three complementary modules: Acquisition Robustness under controlled same-scan spacing changes, Cross-Modal Anatomical Alignment through balanced bidirectional retrieval, and Anatomical Transfer using limited support and case-disjoint queries. These protocols separately characterize acquisition sensitivity, cross-modal structure recovery, and anatomical recovery. Figure 2 summarizes the framework.
Figure 2. Overview of REFORM-3D Framework. The framework assesses frozen 3D representations along three axes: (a) Acquisition Robustness, using controlled same-scan spacing perturbations to measure stability, structural preservation (CKA), and transfer; (b) Cross-Modal Anatomical Alignment, evaluating bidirectional cross-modal retrieval; and (c) Anatomical Transfer from limited labels under case-disjoint evaluation. Plots illustrate main trends across models and metrics.
Pretraining Corpus and Geometric Regimes.
We use REFORM-3D to evaluate Med3DINO, a family of volumetric DINOv2 encoders [12, 1] pretrained on 62.6K unlabeled CT, MR, PET, CTA, and CBCT volumes covering over 180 anatomical structures. The family comprises three geometric pretraining regimes: isotropic normalization (ISO), voxel-relative sampling (REL), and spacing-aware resampling (SA) while fixing the corpus, initialization, architecture, objective, non-geometric augmentations, and optimization budget. This controlled design isolates the complete geometric policy within Med3DINO; other pretrained encoders serve as contextual representation baselines. Further corpus and preprocessing details are provided in Supplementary Section A.
REFORM-3D Modules
REFORM-3D is organized into three modules, each defined by a distinct representation-level question about frozen 3D features. The encoder remains frozen throughout, and each module uses metrics matched to its evaluation setting.
Acquisition Robustness. This module asks whether changing voxel spacing alters a frozen representation when the same scan is held fixed. Let denote a scan, let be a frozen encoder, and let denote deterministic preprocessing followed by controlled resampling of to target spacing . The controlled evaluation therefore compares embeddings across multiple spacing variants of the same scan, so that spacing is the intended source of variation. We evaluate this controlled setting in three complementary ways. The first is within-scan cosine drift:
which measures how far the representation of a scan moves when spacing alone is perturbed. The second is cross-variant CKA [7], computed over the same scans to assess preservation of feature-space organization. The third is semantic transfer across spacing variants, , which asks whether a classifier trained on features at spacing can recover the corresponding dataset-specific semantic targets from features at spacing . We fix cases, targets, five-fold splits, and classifier settings, fitting the standardizer and classifier only at the source spacing and applying them unchanged at the target spacing. Hence, these metrics collectively distinguish embedding movement, feature-space reorganization, and reduced semantic recoverability under controlled resampling.
Cross-Modal Anatomical Alignment. This module evaluates whether labeled structures remain recoverable across modalities under balanced bidirectional retrieval. Its primary evaluation uses organ-level CT–MR retrieval. For a query , let be an organ-balanced candidate pool from the opposite modality, and let denote same-organ positives. Retrieval is evaluated in both CT→MR and MR→CT directions. Candidates are ranked by cosine similarity. We compute average precision (AP) per query, average it within each direction, and then equally across directions:
where is the candidate at rank , is the query set for direction , and is the equal-weight bidirectional mean. We additionally report Top-1 and Top-5 accuracy. Hence, these metrics measure whether same-organ cross-modal matches are ranked above competing organs, without implying voxel-level alignment or full modality invariance.
Anatomical Transfer. This module evaluates whether organ identity can be recovered from frozen features using limited labeled support. The primary setting uses two support samples per organ and modality, while query samples are drawn from cases disjoint from all support cases; the encoder remains frozen. We use balanced accuracy (BA) as the common recoverability metric,
where is the set of evaluated organs and is recall on the case-disjoint queries for organ . Feature standardization is fitted on the support set and applied unchanged to the query set. As the nearest-centroid frozen-feature baseline, we form one support centroid per organ class,
where contains the standardized support embeddings for organ across modalities. Each standardized query embedding is assigned to the organ class whose centroid is nearest in Euclidean distance, yielding . We then train a lightweight linear probe on the same balanced support set and report , together with . These quantities distinguish frozen organ separability, the gain from limited adaptation, and organ recoverability; they do not imply that the evaluated organs were absent during pretraining.
Evaluation Datasets and Surfaces
REFORM-3D does not use one pooled benchmark cohort. Instead, each module uses the evaluation surface required by its scientific question: controlled same-scan spacing perturbation for Acquisition Robustness, balanced cross-modal retrieval for Cross-Modal Anatomical Alignment, and case-disjoint organ classification for Anatomical Transfer. Table 1 groups datasets by their inclusion in the Med3DINO pretraining corpus. These labels describe dataset-level exposure for Med3DINO, not anatomical classes absent from pretraining, and do not automatically apply to external encoders.
| Pretraining exposure | Dataset | Evaluation role |
| Seen in pretraining | AbdomenAtlas [28]; ImageCAS [29]; JHU-Stroke Brain MR [30]; TotalSegmentator-CT [31]; HECKTOR-2025 [32]; | Acquisition Robustness; CT contribution to CT–MR alignment and anatomical transfer; CT–PET lesion-category retrieval |
| Unseen in pretraining | KiTS23 [33]; TotalSegmentator-MR [34]; CHAOS [35]; AMOS22 [36]; MMWHS [37] | Acquisition Robustness; CT–MR alignment; anatomical transfer |
Table 1. Evaluation datasets grouped by inclusion in the Med3DINO pretraining corpus. Exposure is defined at the dataset level and does not imply that individual anatomical classes were unseen.
Acquisition Robustness uses AbdomenAtlas [28], KiTS23 [33], TotalSegmentator-MR [34], ImageCAS [29], and JHU-Stroke Brain MR [30], each converted into controlled spacing variants of the same scan. This module therefore spans seen surfaces (AbdomenAtlas, ImageCAS, and JHU-Stroke Brain MR) as well as pretraining-unseen surfaces (KiTS23 and TotalSegmentator-MR) while preserving the same evidential core: spacing changes while scan identity and anatomy are fixed. Controlled same-scan comparisons carry the main robustness claim; native-spacing analyses provide observational support because they compare different scans with different spacing ranges.
Cross-Modal Anatomical Alignment uses TotalSegmentator CT–MR [31, 34], MMWHS [37], and AMOS22 [36] as balanced multi-organ CT–MR surfaces; CHAOS [35] is reported separately as a liver-only surface. TotalSegmentator CT–MR has mixed Med3DINO exposure, whereas MMWHS, AMOS22, and CHAOS are pretraining-unseen datasets. We additionally evaluate HECKTOR2025 [32] CT–PET using primary-tumor and metastatic-lymph-node retrieval with same-patient targets excluded. Because this surface uses lesion categories, it is interpreted separately from organ-level CT–MR retrieval.
Anatomical Transfer uses TotalSegmentator CT–MR, MMWHS, and AMOS22 with two support samples per organ and modality and case-disjoint queries. TotalSegmentator CT–MR is a mixed-exposure surface, while MMWHS and AMOS22 are pretraining-unseen datasets. These surfaces evaluate organ recoverability from limited labeled support and do not imply that the evaluated organ classes were absent during pretraining.
Benchmark Results
We evaluate frozen 3D representations with the three REFORM-3D benchmark modules: Acquisition Robustness, Cross-Modal Anatomical Alignment, and Anatomical Transfer. We first examine sensitivity to acquisition geometry, followed by cross-modal retrieval and anatomical recoverability across modalities. Each conclusion is restricted to the evidence supported by its evaluation setting. Evaluation dataset construction, metric definitions, and implementation details are provided in Supplementary Sections B, C, and E.
Evaluated Models. We evaluate Med3DINO alongside of nine frozen encoders, including BrainIAC, OpenMind, VoCo, 3DINO, SAM-Med3D, Hi-End-MAE, MambaMIM, MiM, and GL-MAE using their designated feature interfaces. Within the controlled Med3DINO comparison, ISO is pretrained after resampling volumes to a fixed isotropic grid. REL is pretrained on anisotropic volumes, but defines crop scale relative to the current voxel grid. SA is pretrained on anisotropic volumes while defining the through-plane crop extent in physical units and using anisotropy-aware rotation handling. With the remaining pretraining settings fixed, this triplet isolates the complete geometric policy within Med3DINO. External encoders provide contextual comparisons across different pretraining designs. Table 2 summarizes the evaluated models.
| Model | Encoder | Evaluated feature(s) | Modalities | Volumes | Pretraining objective | Pretraining geometry |
| External Encoders | ||||||
| BrainIAC [15] | ViT-B | First patch token | MR | 32.0K | SimCLR | Isotropic normalization |
| OpenMind [16] | Primus-M | GAP | MR/PET† | 113.9K | Volume contrastive | Isotropic normalization |
| VoCo [8] | SwinUNETR | Multiscale GAP | CT | ∼160K | Volume contrastive | Region-specific resampling |
| 3DINO [1] | ViT-L | CLS / GAP | CT/MR/PET† | 98.8K | DINOv2 | Voxel-relative sampling |
| SAM-Med3D [17] | ViT-B | Post-neck GAP | CT/MR | ∼22K | Supervised Dice + CE | Isotropic normalization |
| Hi-End-MAE [18] | ViT | CLS | CT | 10.0K | Hierarchical MAE | Isotropic normalization |
| MambaMIM [19] | CNN–Mamba | Final-stage GAP | CT | 6.8K | Masked reconstruction | Isotropic normalization |
| MiM [20] | ConvViT-B | GAP | CT | 10.5K | MAE + InfoNCE | Multiscale voxel sampling |
| GL-MAE [21] | ViT-B | CLS | CT | 0.75K | MAE + consistency | Multiscale voxel sampling |
| Controlled Med3DINO Family | ||||||
| Med3DINO-ISO | ViT-L | CLS / GAP | CT/MR/PET/CTA/CBCT | 62.6K | DINOv2 | Isotropic normalization |
| Med3DINO-REL | ViT-L | CLS / GAP | CT/MR/PET/CTA/CBCT | 62.6K | DINOv2 | Voxel-relative sampling |
| Med3DINO-SA | ViT-L | CLS / GAP | CT/MR/PET/CTA/CBCT | 62.6K | DINOv2 | Spacing-aware resampling |
Table 2. Evaluated frozen encoders and their pretraining settings. External encoders provide contextual comparisons; the Med3DINO triplet controls other pretraining settings to compare geometric policies. GAP and CLS denote global average pooling over token or spatial positions and class token, respectively; †Predominantly MR or CT/MR with a small PET subset.
Acquisition Robustness Results
Acquisition Robustness evaluates whether spacing changes the frozen representation when scan identity is held fixed. Table 3 is the primary evidence: drift measures feature displacement, CKA measures preservation of feature-space structure, and semantic transfer measures whether label-relevant structure remains usable across spacing variants. Together, these metrics show that the controlled same-scan results do not support one global robustness ranking. Within the controlled ISO/REL/SA comparison, the reported CLS results give REL the lowest drift and SA the highest semantic transfer on three of the four displayed datasets. ImageCAS instead favors ISO for drift and REL for transfer. CKA varies by dataset and feature type. Among the external encoders, MiM and GL-MAE retain high CKA, but SAM-Med3D achieves higher mean transfer than either on KiTS23 and TS-MR. We further provide JHU-Stroke results and paired ISO/REL/SA comparisons in supplementary Tables 13 and 14, respectively. Classifier, semantic-target, and preprocessing sensitivities are reported in Supplementary Sections D.3, D.2, and D.5.
| Method | AbdomenAtlas [28] | KiTS23 [33] | ImageCAS [29] | TS-MR [34] | ||||||||
| Drift↓ | CKA↑ | Trans↑ | Drift↓ | CKA↑ | Trans↑ | Drift↓ | CKA↑ | Trans↑ | Drift↓ | CKA↑ | Trans↑ | |
| External encoders | ||||||||||||
| BrainIAC [15] | 0.30±0.02 | 97.60±0.17 | 67.20±1.92 | 0.30±0.00 | 96.70±0.00 | 46.60±4.89 | 0.90±0.00 | 93.90±0.00 | 52.50±0.59 | 0.50±0.00 | 99.10±0.00 | 55.70±2.43 |
| OpenMind [16] | 0.10±0.05 | 77.70±2.96 | 57.10±2.05 | 1.20±0.26 | 80.70±7.12 | 46.70±2.98 | 0.20±0.18 | 53.00±4.98 | 50.10±0.16 | 0.20±0.01 | 92.60±3.65 | 49.30±1.84 |
| VoCo [8] | 0.80±0.09 | 86.70±0.10 | 74.60±0.15 | 0.70±0.00 | 81.30±0.00 | 46.10±4.07 | 2.30±0.00 | 42.60±0.00 | 52.00±0.13 | 0.10±0.00 | 95.94±0.00 | 71.10±0.82 |
| 3DINO (CLS) [1] | 16.30±0.01 | 87.50±0.07 | 75.10±0.18 | 15.40±0.00 | 77.30±0.00 | 45.50±1.08 | 32.10±0.00 | 83.40±0.00 | 55.90±0.01 | 6.00±0.00 | 92.40±0.00 | 74.60±0.73 |
| 3DINO (GAP) [1] | 3.60±0.00 | 96.20±0.11 | 77.80±0.59 | 3.70±0.00 | 91.90±0.00 | 39.90±2.23 | 11.30±0.00 | 88.30±0.00 | 53.90±0.35 | 1.30±0.00 | 98.90±0.00 | 80.70±0.23 |
| SAM-Med3D [17] | 3.35±0.04 | 86.88±0.37 | 74.66±0.32 | 2.83±0.00 | 95.27±0.00 | 52.82±5.00 | 0.87±0.00 | 96.13±0.00 | 54.23±0.49 | 0.51±0.00 | 97.53±0.00 | 72.61±1.40 |
| Hi-End-MAE [18] | 0.94±0.01 | 97.18±0.17 | 72.68±0.67 | 0.78±0.00 | 97.44±0.00 | 47.99±3.40 | 1.15±0.00 | 93.61±0.00 | 51.87±0.14 | 0.23±0.00 | 99.18±0.00 | 70.28±1.85 |
| MambaMIM [19] | 5.49±0.05 | 90.44±0.38 | 72.17±0.54 | 5.58±0.00 | 94.62±0.00 | 50.26±2.33 | 14.38±0.00 | 83.53±0.00 | 51.38±0.11 | 0.13±0.00 | 98.97±0.00 | 71.25±0.43 |
| MiM [20] | 1.44±0.01 | 99.59±0.02 | 73.69±0.49 | 0.75±0.00 | 99.86±0.00 | 48.94±2.62 | 2.06±0.00 | 99.20±0.00 | 54.01±0.38 | 0.01±0.00 | 99.94±0.00 | 56.35±1.53 |
| GL-MAE [21] | 0.78±0.00 | 99.29±0.01 | 74.65±0.94 | 0.50±0.00 | 99.88±0.00 | 48.51±4.69 | 1.06±0.00 | 99.35±0.00 | 52.79±1.02 | 0.04±0.00 | 99.95±0.00 | 58.70±0.32 |
| Controlled Med3DINO: CLS | ||||||||||||
| Med3DINO-ISO | 19.00±0.09 | 78.50±0.14 | 73.60±0.78 | 20.00±0.00 | 73.60±0.00 | 34.80±4.02 | 22.00±0.00 | 93.10±0.00 | 52.90±0.57 | 7.00±0.00 | 92.40±0.00 | 59.30±0.34 |
| Med3DINO-REL | 10.90±0.07 | 89.10±0.13 | 77.20±0.61 | 12.00±0.00 | 86.10±0.00 | 44.10±2.22 | 24.20±0.00 | 83.30±0.00 | 54.60±0.45 | 5.60±0.00 | 93.50±0.00 | 77.00±0.91 |
| Med3DINO-SA | 18.40±0.06 | 85.30±0.05 | 81.00±0.16 | 19.20±0.00 | 84.30±0.00 | 57.80±3.25 | 35.60±0.00 | 83.80±0.00 | 54.20±0.37 | 5.70±0.00 | 94.20±0.00 | 80.60±1.18 |
| Controlled Med3DINO: GAP | ||||||||||||
| Med3DINO-ISO | 4.10±0.02 | 95.90±0.11 | 72.50±0.15 | 3.90±0.00 | 91.50±0.00 | 43.80±2.41 | 13.20±0.00 | 92.40±0.00 | 53.40±0.23 | 2.00±0.00 | 97.90±0.00 | 78.00±0.87 |
| Med3DINO-REL | 1.90±0.03 | 96.70±0.06 | 78.90±0.78 | 4.40±0.00 | 92.60±0.00 | 46.10±3.55 | 12.30±0.00 | 90.80±0.00 | 53.40±0.43 | 1.80±0.00 | 97.40±0.00 | 81.70±1.05 |
| Med3DINO-SA | 5.40±0.02 | 97.00±0.02 | 79.70±0.14 | 5.80±0.00 | 94.30±0.00 | 49.20±3.32 | 9.70±0.00 | 85.80±0.00 | 53.70±0.24 | 1.70±0.00 | 99.20±0.00 | 83.50±0.57 |
Table 3. Controlled same-scan acquisition robustness under spacing perturbations. Reported results are mean±SD over three-seed evaluations. External encoders provide contextual comparisons; ISO/REL/SA form the controlled geometric-policy comparison. 3DINO and Med3DINO use CLS and GAP; other feature interfaces follow Table 2. TS-MR denotes TotalSegmentator-MR.
Figure 3 further provides a local feature-space view of acquisition robustness. VoCo [8] retains uniformly high cosine similarity but weak diagonal–off-diagonal separation. MiM [20] also maintains high same-organ similarity, while 3DINO [1] shows greater organ-specific separation. SAM-Med3D [17] and Med3DINO-SA exhibit larger displayed margins under both perturbation conditions. These illustrative profiles distinguish high same-organ similarity from separation between anatomical structures.
Figure 3. Organ-specific feature separation under controlled same-scan spacing perturbations in AbdomenAtlas. Heatmaps show cosine similarity between dense features pooled within organ masks at reference spacing (1 × 1 × 1 mm) and moderate (1 × 1 × 3 mm; top) or severe (1 × 1 × 5 mm; bottom) target spacings. Diagonal entries compare the same organ; off-diagonal entries compare different organs. The margin is mean diagonal minus mean off-diagonal similarity, distinguishing organ-specific correspondence from uniformly high similarity.
Native-spacing results in Table 4 provide supporting, but not primary, evidence because they compare different scans rather than controlled variants of the same scan. Even in this observational setting, Med3DINO-SA gives the highest semantic transfer for both CLS-token and patch-token features across the three datasets, while CKA remains more feature- and dataset-dependent. These analyses distinguish embedding stability from semantic recoverability, rather than establishing one acquisition-robustness ranking across datasets and features.
| Method | AbdomenAtlas [28] | KiTS23 [33] | TotalSegmentator-MR [34] | |||
| CKA↑ | Trans↑ | CKA↑ | Trans↑ | CKA↑ | Trans↑ | |
| Model-Specific Features (CLS for 3DINO and Med3DINO) | ||||||
| BrainIAC [15] | 0.50 | 61.20 | 2.70 | 45.90 | 2.70 | 51.60 |
| OpenMind [16] | 0.30 | 52.30 | 3.70 | 51.00 | 4.00 | 48.60 |
| VoCo [8] | 0.60 | 66.10 | 6.10 | 49.90 | 6.60 | 59.70 |
| 3DINO [1] | 14.10 | 66.40 | 52.00 | 49.80 | 49.20 | 65.90 |
| Med3DINO-ISO | 16.20 | 65.90 | 54.70 | 47.70 | 45.00 | 56.40 |
| Med3DINO-REL | 13.70 | 67.10 | 48.40 | 54.20 | 38.90 | 65.60 |
| Med3DINO-SA | 15.60 | 71.00 | 50.80 | 56.40 | 35.20 | 67.20 |
| Average-Pooled Patch-token Features | ||||||
| 3DINO [1] | 13.20 | 68.30 | 11.80 | 52.20 | 12.80 | 66.20 |
| Med3DINO-ISO | 5.30 | 69.50 | 13.90 | 54.70 | 10.90 | 60.90 |
| Med3DINO-REL | 12.70 | 67.10 | 17.20 | 54.50 | 13.90 | 66.60 |
| Med3DINO-SA | 13.30 | 72.30 | 18.40 | 59.60 | 12.70 | 69.30 |
Table 4. Native-spacing observational analysis across spacing groups. CKA measures cross-group feature-space similarity, and semantic transfer (Trans) measures whether label-relevant structure remains usable across native-spacing differences. The first group uses CLS for 3DINO and Med3DINO; other interfaces follow Table 2.
Cross-Modal Anatomical Alignment Results
This module evaluates same-organ CT–MR recoverability under balanced bidirectional retrieval in frozen feature space. Table 5 reports mAP, Top-1, and Top-5, averaging the two retrieval directions. Within the controlled Med3DINO comparison, SA achieves the highest scores across all three metrics on TotalSegmentator CT–MR, MMWHS, and AMOS22 with both CLS and GAP features. GAP further increases SA’s retrieval scores relative to CLS on these datasets. Among the added encoders, SAM-Med3D has the highest mAP on TotalSegmentator and AMOS22, whereas Hi-End-MAE leads on MMWHS, revealing dataset-dependent retrieval strengths. CHAOS results are interpreted separately because it evaluates identifier-based pairing between different CT and MR patients for liver retrieval rather than multi-organ discrimination. These results support stronger cross-modal organ recoverability under spacing-aware pretraining within the controlled recipe, using crops that retain surrounding context.
| Method | TotalSeg CT–MR [34, 31] | MMWHS [37] | AMOS22 [36] | CHAOS [35] (liver-only) | ||||||||
| mAP | Top-1 | Top-5 | mAP | Top-1 | Top-5 | mAP | Top-1 | Top-5 | mAP | Top-1 | Top-5 | |
| External encoders | ||||||||||||
| BrainIAC [15] | 9.90±0.08 | 11.70±0.43 | 32.50±0.87 | 21.60±0.00 | 19.30±0.00 | 38.90±0.00 | 10.50±0.01 | 12.60±0.27 | 31.90±0.53 | 38.60±0.00 | 18.80±0.00 | 62.50±0.00 |
| OpenMind [16] | 10.50±0.32 | 9.60±1.11 | 34.30±1.29 | 17.60±2.45 | 15.00±4.21 | 43.90±6.48 | 10.80±1.24 | 12.30±1.62 | 39.70±2.46 | 32.70±6.35 | 12.50±9.55 | 56.20±6.25 |
| VoCo [8] | 11.40±0.12 | 18.90±1.79 | 49.90±2.28 | 19.30±0.00 | 13.20±0.00 | 25.40±0.00 | 16.30±0.11 | 25.70±0.42 | 50.30±0.70 | 32.40±0.00 | 6.20±0.00 | 68.80±0.00 |
| 3DINO (CLS) [1] | 17.60±0.06 | 32.20±0.51 | 60.60±0.61 | 29.40±0.00 | 40.70±0.00 | 77.10±0.00 | 21.10±0.09 | 27.40±1.21 | 57.10±0.59 | 24.60±0.00 | 6.20±0.00 | 50.00±0.00 |
| 3DINO (GAP) [1] | 20.10±0.16 | 36.90±1.59 | 64.50±1.77 | 30.20±0.00 | 35.70±0.00 | 76.40±0.00 | 28.00±0.11 | 44.60±0.40 | 77.60±0.46 | 28.10±0.00 | 6.20±0.00 | 56.20±0.00 |
| SAM-Med3D [17] | 13.61±0.09 | 21.01±0.21 | 51.59±0.59 | 18.30±0.00 | 15.36±0.00 | 36.43±0.00 | 15.32±0.13 | 24.48±0.53 | 45.75±0.92 | 31.00±0.00 | 6.25±0.00 | 68.75±0.00 |
| Hi-End-MAE [18] | 11.03±0.07 | 20.71±0.70 | 49.96±2.19 | 19.10±0.00 | 12.50±0.00 | 42.86±0.00 | 13.28±0.05 | 15.78±0.27 | 42.64±1.02 | 33.97±0.00 | 12.50±0.00 | 62.50±0.00 |
| MambaMIM [19] | 10.78±0.05 | 13.54±0.40 | 36.58±1.37 | 18.27±0.00 | 13.93±0.00 | 38.21±0.00 | 13.44±0.06 | 12.72±0.25 | 25.10±0.00 | |||
| MiM [20] | 9.00±0.05 | 9.56±1.00 | 31.49±2.44 | 18.26±0.00 | 15.36±0.00 | 42.50±0.00 | 9.58±0.04 | 11.37±0.46 | 28.32±0.58 | 33.97±0.00 | 12.50±0.00 | 62.50±0.00 |
| GL-MAE [21] | 9.34±0.04 | 9.69±0.12 | 29.76±0.97 | 17.40±0.00 | 13.93±0.00 | 44.29±0.00 | 9.76±0.01 | 8.13±0.71 | 25.61±0.82 | 29.12±0.00 | 6.25±0.00 | 68.75±0.00 |
| Controlled Med3DINO: CLS | ||||||||||||
| Med3DINO-ISO | 14.60±0.13 | 23.20±1.02 | 54.00±1.35 | 28.10±0.00 | 31.40±0.00 | 60.00±0.00 | 20.00±0.12 | 32.70±0.22 | 61.20±0.53 | 24.90±0.00 | 0.00±0.00 | 62.50±0.00 |
| Med3DINO-REL | 18.10±0.06 | 33.80±0.77 | 64.80±0.24 | 25.40±0.00 | 32.10±0.00 | 69.60±0.00 | 23.50±0.10 | 38.00±0.66 | 69.60±0.16 | 37.40±0.00 | 12.50±0.00 | 75.00±0.00 |
| Med3DINO-SA | 19.90±0.06 | 41.10±0.20 | 72.20±0.23 | 31.10±0.00 | 43.90±0.00 | 82.90±0.00 | 28.30±0.14 | 56.70±0.73 | 84.30±0.24 | 48.40±0.00 | 25.00±0.00 | 93.80±0.00 |
| Controlled Med3DINO: GAP | ||||||||||||
| Med3DINO-ISO | 16.20±0.11 | 26.80±0.50 | 54.60±1.33 | 25.90±0.00 | 26.10±0.00 | 56.10±0.00 | 21.60±0.04 | 27.80±0.13 | 59.60±0.42 | 33.60±0.00 | 12.50±0.00 | 62.50±0.00 |
| Med3DINO-REL | 21.00±0.11 | 50.80±1.07 | 65.80±0.59 | 39.20±0.00 | 43.90±0.00 | 72.50±0.00 | 31.80±0.54 | 54.00±0.70 | 78.00±0.37 | 35.50±0.00 | 12.50±0.00 | 68.80±0.00 |
| Med3DINO-SA | 27.20±0.24 | 57.00±0.68 | 78.10±0.42 | 41.90±0.00 | 48.60±0.00 | 83.20±0.00 | 44.80±0.09 | 74.80±0.66 | 91.20±0.05 | 42.00±0.00 | 18.80±0.00 | 75.00±0.00 |
Table 5. Frozen bidirectional CT–MR retrieval. Results are reported as mean±SD over three-seed evaluations. 3DINO and Med3DINO use CLS and GAP; other feature interfaces follow Table 2.
Anatomical Transfer Results
Anatomical Transfer evaluates whether organ identity remains recoverable from limited labeled support under case-disjoint evaluation. Table 6 reports three linked quantities: for nearest-centroid separability, for recoverability after limited adaptation, and for the change relative to the centroid baseline. Within the controlled Med3DINO comparison, SA achieves the highest probe BA on TotalSegmentator CT–MR, MMWHS, and AMOS22 with both CLS and GAP features, with higher scores from GAP. Among the added encoders, Hi-End-MAE achieves the highest probe BA on all three datasets. Adaptation gain must be interpreted alongside final accuracy: a larger gain can reflect a weaker centroid baseline rather than a stronger final representation. The results therefore distinguish organ separability in frozen features from the recoverability achieved through limited supervision. Supplementary Sections D.3 and D.4 examine classifier and support-budget dependence.
| Method | TotalSeg | CT–MR [34, 31] | MMWHS [37] | AMOS22 [36] | ||||||
| External encoders | ||||||||||
| BrainIAC [15] | ||||||||||
| OpenMind [16] | ||||||||||
| VoCo [8] | ||||||||||
| 3DINO (CLS) [1] | ||||||||||
| 3DINO (GAP) [1] | ||||||||||
| SAM-Med3D [17] | ||||||||||
| Hi-End-MAE [18] | ||||||||||
| MambaMIM [19] | ||||||||||
| MiM [20] | ||||||||||
| GL-MAE [21] | ||||||||||
| Controlled Med3DINO: CLS | ||||||||||
| Med3DINO-ISO | ||||||||||
| Med3DINO-REL | ||||||||||
| Med3DINO-SA | ||||||||||
| Controlled Med3DINO: GAP | ||||||||||
| Med3DINO-ISO | ||||||||||
| Med3DINO-REL | ||||||||||
| Med3DINO-SA |
Table 6. Case-disjoint organ classification with two support samples per organ and modality. Mean±SD are reported over three-seed evaluations. 3DINO and Med3DINO use CLS and GAP; other feature interfaces follow Table 2.
An additional case-disjoint linear-probe evaluation with larger labeled support (Figure 4) reveals class-specific differences beyond aggregate BA. All four encoders achieve high organ recall on AMOS-MR, whereas KiTS23 errors predominantly involve tumor–cyst confusion. Med3DINO-SA achieves the highest BA on both cohorts, although 3DINO has higher kidney recall, showing that overall recoverability does not imply uniform class-level superiority.
Figure 4. Case-disjoint organ classification of frozen crop features on KiTS23 CT (top) and AMOS-MR (bottom). Logistic classifiers use 40 and 38 labeled, context-inclusive crops per class, respectively. Cells show row-normalized percentages; panel titles report BA. 3DINO and Med3DINO-SA use CLS features, VoCo uses multiscale GAP, and SAM-Med3D-turbo uses post-neck GAP.
In summary, within the controlled Med3DINO comparison, REL has lower reported CLS drift than SA on the four displayed acquisition datasets, whereas SA achieves the highest reported cross-modal retrieval scores and probe BA on the three multi-organ CT–MR datasets with both CLS and
GAP. Semantic transfer and CKA remain dataset- and feature-dependent. The retrieval and probe results span both mixed-exposure and pretraining-unseen datasets. REFORM-3D therefore separates embedding stability from anatomical recoverability rather than establishing one global model ranking.
Downstream Performance
Downstream results are included as secondary evidence rather than as the basis of the framework’s main claims. Table 7 gives the segmentation summary, organized into seen datasets, unseen datasets, and one unseen-modality transfer setting. Within Med3DINO family, SA achieves the highest reported Dice on all ten datasets and the lowest HD95 on nine; ISO achieves lower HD95 on AMOS-MR. Among external comparisons, 3DINO achieves higher BTCV Dice. These results are consistent with the cross-modal retrieval and probe results, but downstream scores also depend on decoder choice, supervision, and optimization. We therefore use downstream performance to show practical transfer relevance on the studied tasks, not to replace the representation-level benchmark. The segmentation protocol is detailed in Supplementary Section E.5.
Table 7: Segmentation performance across 10 downstream datasets, grouped by their relationship to Med3DINO pretraining: seen/unseen datasets and unseen-modality transfer. Exposure labels refer to Med3DINO and do not automatically apply to external encoders. Dice (%) and HD95 (mm) are reported; higher Dice and lower HD95 are better. TS-CT denotes TotalSegmentator-CT [31].
| Method | BTCV [38] Dice | BTCV [38] HD95 | BraTS-GLI [39] Dice | BraTS-GLI [39] HD95 | ISLES22 [40] Dice | ISLES22 [40] HD95 | WORD [41] Dice | WORD [41] HD95 | TS-CT [31] Dice | TS-CT [31] HD95 | AMOS-CT [36] Dice | AMOS-CT [36] HD95 | AMOS-MR [36] Dice | AMOS-MR [36] HD95 | KiTS23 [33] Dice | KiTS23 [33] HD95 | LA-SEG [42] Dice | LA-SEG [42] HD95 | TDSC-ABUS [43] Dice | TDSC-ABUS [43] HD95 |
| MedDINOv3 [3] | 78.79 | – | – | – | – | – | – | – | – | – | 87.38 | – | – | – | 70.68 | – | – | – | – | – |
| 3DINO [1] | 82.10 | 9.4 | 91.80 | 3.90 | 63.39 | 11.08 | 85.46 | 6.83 | 86.78 | 5.83 | 85.56 | 5.01 | 80.69 | 5.54 | 80.75 | 13.87 | 92.40 | 5.20 | 47.70 | 89.10 |
| Med3DINO-ISO | 64.71 | 15.56 | 91.70 | 3.46 | 64.98 | 9.87 | 86.10 | 7.50 | 86.94 | 4.96 | 83.35 | 4.99 | 82.12 | 4.69 | 88.00 | 19.61 | 95.69 | 1.96 | 72.78 | 75.61 |
| Med3DINO-REL | 65.50 | 7.94 | 91.77 | 3.54 | 67.76 | 9.37 | 86.65 | 6.30 | 88.79 | 3.83 | 85.46 | 4.28 | 82.07 | 5.58 | 88.11 | 14.57 | 95.17 | 1.97 | 74.94 | 68.72 |
| Med3DINO-SA | 75.69 | 5.76 | 92.17 | 3.13 | 70.70 | 6.42 | 86.79 | 6.07 | 88.96 | 3.52 | 87.88 | 3.82 | 82.17 | 4.83 | 88.50 | 9.15 | 95.80 | 1.90 | 75.91 | 65.29 |
Table 7. Segmentation performance across 10 downstream datasets, grouped by their relationship to Med3DINO pretraining: seen/unseen datasets and unseen-modality transfer. Exposure labels refer to Med3DINO and do not automatically apply to external encoders. Dice (%) and HD95 (mm) are reported; higher Dice and lower HD95 are better. TS-CT denotes TotalSegmentator-CT [31].
Conclusion
We presented REFORM-3D, a representation-centric framework for understanding frozen 3D medical representations under acquisition variation, cross-modal anatomy, and case-disjoint anatomical transfer. Instead of treating downstream task performance as sufficient evidence of representation quality, the framework evaluates whether features remain stable when spacing changes while anatomy is held fixed, whether labeled structures remain recoverable across modalities under balanced bidirectional retrieval, and whether organ identity is recoverable from limited labeled support under case-disjoint evaluation. Across Med3DINO and external encoders, these evaluations reveal distinct strengths in representation stability and semantic or anatomical recoverability that downstream task scores alone do not distinguish. By making these properties measurable under controlled evaluation settings, the benchmark clarifies semantic and anatomical recoverability from frozen 3D representations, alongside their sensitivity to acquisition geometry and modality differences.
Limitations. REFORM-3D characterizes frozen representations on specific acquisition, cross-modal retrieval, and case-disjoint anatomical transfer surfaces, but does not establish broader invariance or replace downstream evaluation. Acquisition robustness is evaluated primarily through controlled resampling, which does not reproduce the full variability of clinical image acquisition and should therefore be interpreted as geometric stress testing rather than complete acquisition realism. The REL–SA findings are also established within a single architecture and self-supervised objective; their generality requires matched geometric-policy comparisons under other pretraining recipes.
Societal Impact. REFORM-3D can support more transparent evaluation and informed selection of medical image encoders. Overreliance on benchmark rankings may obscure performance differences across patient groups and acquisition settings. Downstream clinical applications require validation in their intended settings, assessment across relevant patient groups, and safeguards for patient privacy.
Acknowledgments and Disclosure of Funding
This research was funded by the Center for Autonomous Robotic Systems (CARS), Khalifa University of Science and Technology (KU-CARS).
Pretraining Details and Data Composition
The Med3DINO encoders are pretrained with a volumetric adaptation of DINOv2 [12] using 3D Vision Transformers and student-teacher self-supervised learning, following 3DINO [1]. This section presents the data and training details needed to interpret the benchmark. The main benchmark evaluates frozen encoders, so the pretraining description is included to clarify the data scale, modality breadth, and geometric assumptions compared by the ISO, REL, and SA regimes.
Corpus Composition and Source Inventory
The pretraining corpus comprises 62,638 unlabeled 3D multimodal volumes retained after quality curation of the source collections in Table 9. Individual modality and sequence images are treated as separate volumes during pretraining. The inventory lists 64,880 dataset-level samples across 65 source datasets. These counts sum entries across source collections rather than unique patients or individual image volumes. The validation and preprocessing stages are described in Section A.3. CT and MR dominate the retained corpus, while PET, CTA, and CBCT extend the acquisition spectrum. Table 8 summarizes the retained corpus by modality and lists representative pathology-associated labels. Figure 5 illustrates anatomical coverage from the corpus mapping of 238 fine-grained labels consolidated into 182 organ cores across 9 coarse anatomical regions. This taxonomy describes pretraining exposure, not the label set of every benchmark evaluation.
| Modality | Volumes | Share (%) | Region | Pathology-associated labels |
| CT | 34,052 | 54.4 | Abdomen | colon cancer primaries; kidney tumor; liver tumor; pancreatic tumor |
| MR | 23,245 | 37.1 | Brain | enhancing tumor; ischemic stroke lesion; non-enhancing tumor; vestibular schwannoma |
| PET | 3,368 | 5.4 | Thorax | buckle rib fracture; lung cancer |
| CTA | 1,070 | 1.7 | Head and neck | nasopharynx cancer |
| CBCT | 903 | 1.4 | Pelvis | prostate cancer |
| Total Corpus | 62,638 | 100% | Other | lesion, unspecified |
Table 8. Pretraining corpus composition. Left: modality distribution over 62,638 unlabeled 3D volumes. Right: organ and lesion labels associated with disease findings in the corpus mapping.
Figure 5. Summary of anatomical coverage in the pretraining corpus. The listed structures are representative labels from the corpus mapping rather than an exhaustive benchmark label set.
Table 9: Source-collection inventory, totaling 64,880 listed samples. Counts follow dataset-level units rather than individual image volumes: a paired CT/PET sample contributes two volumes, while multi-sequence MR cases contribute separate sequence images. The listed samples account for at least 81,319 source image volumes before curation, including documented modality and sequence expansions. Access requirements are separate from licenses; “No explicit” denotes an unspecified license in this inventory, not unrestricted use.
| Dataset | Mod. | Version | License | Access | Source samples |
| AbdomenCT-1K [44] | CT | V1 | CC BY 4.0 | Request | 1062 |
| ATM22 [45] | CT | V1 | CC BY-NC | Agreement | 500 |
| BraTS15 [46] | MR | V1 | No explicit | Registration | 384 |
| BraTS18 [47] | MR | V1 | MIT | Custom (BraTS terms) | 542 |
| BraTS19 [48] | MR | V1 | No explicit | Registration | 626 |
| BraTS20 [48] | MR | V1 | No explicit | Request | 369 |
| BraTS21 [39] | MR | V1 | CC BY 4.0 | Registration | 2040 |
| BrainPTM [49] | MR | V1 | Custom | Agreement | 75 |
| BTCV_Cervix [38] | CT | V1 | CC BY 4.0 | Registration | 30 |
| COSMOS22 [50] | MR | V1 | No explicit | Request | 50 |
| COVID19CTscans [51] | CT | V1 | CC BY-NC-SA | Open | 20 |
| CrossMoDA21 [52] | MR | V1 | CC BY-SA 4.0 | Open | 379 |
| CrossMoDA22 [53] | MR | V2 | CC BY-NC-SA 4.0 | Open | 755 |
| CT-ORG [54] | CT | V1 | CC BY 3.0 | Open | 140 |
| CTPelvic1k [55] | CT | V1 | CC BY-NC-SA 4.0 | Open | 1184 |
| FLARE21 [56] | CT | V1 | CC BY-NC-SA 4.0 | Registration | 511 |
| FLARE22 [57] | CT | V2 | No explicit | Registration | 2300 |
| ISLES22 [40] | MR | V1 | CC BY 4.0 | Registration | 250 |
| ISLES24 [58] | CT/MR | V1 | CC BY-NC-SA 4.0 | Registration | 149 |
| KIPA22 [59] | CT | V1 | CC BY-NC-ND 4.0 | Agreement | 130 |
| JHU-Stroke [30] | MR | V6 | CC BY | Custom (DUA) | 2888 |
| LAScarQS22 [60] | MR | V1 | CC BY-NC-ND 4.0 | Agreement | 194 |
| LiTS [61] | CT | V1 | CC BY-NC-SA | Registration | 201 |
| LUNA16 [62] | CT | V1 | CC BY 4.0 | Open | 888 |
| MSD BrainTumour [63] | MR | V1 | CC BY-SA 4.0 | Open | 750 |
| MSD Colon [63] | CT | V1 | CC BY-SA 4.0 | Open | 190 |
| MSD Heart [63] | MR | V1 | CC BY-SA 4.0 | Open | 30 |
| MSD HepaticVessel [63] | CT | V1 | CC BY-SA 4.0 | Open | 443 |
| MSD Hippocampus [63] | MR | V1 | CC BY-SA 4.0 | Open | 394 |
| MSD Liver [63] | CT | V1 | CC BY-SA 4.0 | Open | 201 |
| MSD Lung [63] | CT | V1 | CC BY-SA 4.0 | Open | 96 |
| MSD Pancreas [63] | CT | V1 | CC BY-SA 4.0 | Open | 420 |
| MSD Prostate [63] | MR | V1 | CC BY-SA 4.0 | Open | 48 |
| MSD Spleen [63] | CT | V1 | CC BY-SA 4.0 | Open | 61 |
| AbdomenAtlas [28] | CT | V1 | CC BY-NC-SA 4.0 | Open | 9262 |
| PICAI [64] | MR | V2 | CC BY-NC 4.0 | Registration | 1500 |
| Promise09 [65] | MR | V1 | CC BY-SA | No explicit | 15 |
| Promise12 [66] | MR | V2 | No explicit | Registration | 100 |
| RibFrac2020 [67] | CT | V1 | CC BY-NC 4.0 | Open | 660 |
| SLIVER07 [68] | CT | V3 | No explicit | Open | 30 |
| STACOM-SLAWT [69] | CT/MR | V1 | CC BY 4.0 | Open | 20 |
| StructSeg19 [70] | CT | V1 | No explicit | Open | 100 |
| TotalSegmentator-CT [31] | CT | V1 | CC BY 4.0 | Open | 1204 |
| VerSe19 [71] | CT | V1 | CC BY-SA 4.0 | Open | 160 |
| VerSe20 [72] | CT | V2 | CC BY-SA 4.0 | Open | 319 |
| WORD [41] | CT | V0.1 | GPL-3.0 | Open | 150 |
| RSNA-2023 [73] | CT | V1 | Custom | Registration | 4274 |
| RDA-Chest-CT [74] | CT | V1 | CC BY-NC-ND 4.0 | Request | 3630 |
| ULS-2023 [75] | CT | V2 | CC BY-NC-SA 4.0 | Open | 6514 |
| HECKTOR-2025 task 1 [32] | CT/PET | V1 | CC BY-NC-SA 4.0 | Request | 680 |
| HECKTOR-2025 task 2 [32] | CT/PET | V1 | CC BY-NC-SA 4.0 | Request | 666 |
| autoPET (FDG) [76] | CT/PET | I | CC BY-NC 4.0 | Registration | 1014 |
| autoPET (FDG+PSMA) [77] | CT/PET | III | CC BY-NC 4.0 | Registration | 1548 |
| Duke Liver [78] | MR | V2 | CC BY-NC-ND 4.0 | Request | 2146 |
| ImageCAS [29] | CTA | V1 | Apache-2.0 | Open | 1000 |
| ImageTAAD [79] | CTA | V1 | Apache-2.0 | Open | 120 |
| ImageTBAD [80] | CTA | V1 | Apache-2.0 | Open | 100 |
| CTSpine1K [81] | CT | V1 | CC BY-NC-SA 4.0 | Open | 1005 |
| fastMRI (Brain) [82] | MR | V1 | Custom | Request | 6970 |
| fastMRI (Breast) [82] | MR | V1 | Custom | Request | 300 |
| fastMRI (Prostate) [82] | MR | V1 | Custom | Request | 312 |
| fastMRI (Knee) [82] | MR | V1 | Custom | Request | 1398 |
| ToothFairy [83] | CBCT | V1 | CC BY-SA 4.0 | Registration | 532 |
| ToothFairy2 [84] | CBCT | V1 | CC BY-SA 4.0 | Registration | 480 |
| STS-Tooth [85] | CBCT | V1 | CC BY 4.0 | Open | 371 |
| Subtotals: CT: 35,685; MR: 22,515; CT/MR: 169; CT/PET: 3,908; CTA: 1,220; CBCT: 1,383 | Total source samples: 64,880 |
Table 9.
Field-of-View and Spacing Distributions
To quantify acquisition geometry in the pretraining corpus, we paired each volume’s voxel spacing with its image shape and computed physical field of view (FOV) along axis as . The summaries average spacing and FOV over the first two recorded image axes and use the third axis separately, denoted in-plane and through-plane, respectively. Median spacing is 1.30 mm in-plane and 2.00 mm through-plane, with 1{sup}st–99{sup}th` percentile ranges of 0.36–5.47 mm and 0.50–6.60 mm, respectively. The corresponding percentile FOV ranges are 140.00–814.57 mm in-plane and 103.00–1005.00 mm through-plane.
Figure 6. Pretraining-corpus acquisition geometry. Left: voxel-spacing distributions. Right: physical field-of-view distributions. These figures show why fixed voxel-space crops can correspond to different physical anatomical support across the corpus.
Figure 6 summarizes variation in voxel spacing and physical coverage. Consequently, a crop specified only in voxel units does not correspond to fixed physical anatomical support across scans. This motivates the ISO, REL, and SA comparison, but corpus geometry alone does not establish representation robustness; acquisition sensitivity is evaluated through the controlled same-scan spacing perturbations defined in Section C.
Preprocessing and Validation
Corpus curation combined spatial screening, file-integrity validation, and preprocessing-compatibility checks. Within the selected modalities, volumes were required to contain at least 32 slices and 96 voxels along both in-plane axes. Validation assessed compressed-stream and NIfTI integrity, consistency between headers and voxel arrays, spacing and affine validity, physical coverage, finite voxel values, and intensity variation. Modality-specific intensity-encoding correction and clipping preceded checks of compatibility with normalization, foreground cropping, and FOV handling. Volumes failing validation were excluded, with rejection reasons recorded.
During loading, a single time point or channel was selected when necessary, and NaNs were replaced by the sample-level mean. Intensities were normalized using the 0.05{sup}th and 99.95{sup}th percentiles and mapped to [-1,1]. Volumes were then cropped to foreground defined by intensities above , with voxel-spacing metadata used to identify and reorder the slice axis.
Before multi-crop augmentation, offline validation assessed foreground content and intensity variation in the normalized, foreground-cropped volume. Voxels with intensity above −0.95 had to occupy at least 5% of the cropped volume; the image intensity variance had to be at least 0.01, and a nonempty foreground bounding box was required. The final pretraining manifest contains 62,638 volumes that passed all validation stages, including these foreground and intensity-variance checks. Foreground selection and validation were intensity-based and did not require segmentation labels.
Self-Supervised Training Objective
Med3DINO adapts 3DINO [1] to volumetric medical imaging with a 3D Vision Transformer backbone. The default training backbone is ViT-L/16 with cubic patch embedding. For a global crop, the encoder produces a patch grid, corresponding to 216 patch tokens, plus one CLS token. The self-supervised objective combines DINO self-distillation on CLS tokens, iBOT masked patch prediction on patch tokens, and KoLeo regularization on student CLS features. The teacher network is an exponential moving average of the student and is not updated by backpropagation.
The default configuration uses two global crops of size and eight local crops of size . DINO and iBOT projection heads each use 65,536 prototypes, a bottleneck dimension of 256, 3 layers, and hidden dimension 2048. iBOT masks patch tokens with mask probability 0.5 and mask-ratio range [0.2, 0.75]; the default configuration uses a separate iBOT head. KoLeo loss is applied with weight 0.1. Teacher temperature is 0.07 after warmup, warmup teacher temperature is 0.04, and teacher momentum increases from 0.992 to 1.0. All three variants use AdamW with a per-GPU batch size of 64 for 100 epochs of 1,250 iterations each (125,000 updates), base learning rate 0.002, 10 warmup epochs, weight decay from 0.04 to 0.4, gradient clipping at 3.0, patch-embedding learning-rate multiplier 0.2, and layerwise decay 0.9. The base learning rate is scaled as , where is the global batch size.
Geometric Pretraining Regimes
The three regimes use the same corpus and shared training setup, while varying input geometry, crop definition, and rotation handling. ISO resamples volumes to 1.5 × 1.5 × 1.5 mm spacing before voxel-relative cropping; REL retains native spacing and uses voxel-relative crops; SA retains native spacing and combines relative in-plane with physical through-plane sampling. The comparison is interpreted at the level of frozen representations learned under these complete geometric policies, not as an isolated ablation of a single augmentation parameter. Table 10 separates the shared settings from the varying components.
| Component | Controlled setting |
| Shared data and model | 62,638-volume corpus; initialization policy; ViT-L/16. |
| Shared optimization | DINO/iBOT/KoLeo; non-geometric augmentations; crop counts and output sizes; batch size; AdamW schedule; 125K updates. |
| ISO geometry | Resampling to 1.5 × 1.5 × 1.5 mm followed by voxel-relative crops. |
| REL geometry | Retained anisotropy with voxel-relative crops. |
| SA geometry | Retained anisotropy with physical through-plane crop extents and anisotropy-aware rotation handling. |
Table 10. Fixed and varying components of the Med3DINO geometric-policy comparison. The intervention is the complete geometric policy, including input geometry, crop definition, and rotation handling; it is not an isolated change to crop coordinates.
In the relative regime, global and local crops are sampled with 3D random resized crops. Global crops use in-slice scale range [0.48, 1.0] and cross-slice scale range [0.5, 1.0]; local crops use in-slice scale range [0.16, 0.48] and cross-slice scale range [0.2, 0.5]. Rotations are applied without an anisotropy gate. In the spacing-aware regime, crops combine relative in-plane sampling with physical through-plane sampling. Global crops use through-plane physical scale range [120, 280] mm and local crops use [40, 100] mm. Rotations are gated by anisotropy with threshold 2.0 so that cross-plane rotations are avoided when they would create implausible orientation changes for highly anisotropic data.
Benchmark Dataset Construction
Each module uses a dataset construction rule specific to its representation question. Acquisition Robustness compares resampled variants of the same scan. Cross-Modal Anatomical Alignment requires a shared label definition and sufficient samples in both modalities. Anatomical Transfer uses organ-level support and query samples from disjoint cases. Dataset exposure refers specifically to the Med3DINO pretraining corpus, not to external encoders pretraining.
Acquisition Robustness Datasets
The controlled Acquisition Robustness setting starts from source scans and creates spacing variants of the same scan. Table 11 summarizes full and sampled manifest sizes from the source scans used for controlled evaluation. For CT and CTA settings, the chosen target spacings are mm, mm, and mm. These variants represent isotropic, moderately anisotropic, and highly anisotropic through-plane sampling while holding in-plane spacing fixed. For MR settings, the controlled protocol keeps each scan’s native in-plane spacing and varies target through-plane spacing using 2.0, 4.0, and 6.0 mm targets. This MR protocol avoids forcing MR scans onto a CT-like in-plane spacing while still testing through-plane sensitivity.
| Acquisition Robustness | |||
| Dataset | Full-manifest scans | Sampled scans | Controlled scans |
| AbdomenAtlas [28] | 9,208 | 3,000 | 1,000 |
| KiTS23 [33] | 489 | 489 | 69 |
| ImageCAS [29] | 1,000 | 1,000 | 708 |
| TotalSegmentator-MR [34] | 616 | 616 | 131 |
| JHU-Stroke [30] | 1,853 | 1,138 | 131 |
| Multi-organ CT–MR retrieval | |||
| Dataset | Source cases: CT/MR | CT→MR: Q/T | MR→CT: Q/T |
| TotalSegmentator [31, 34] | 1,204/616 | 6,648/1,032 | 1,032/6,648 |
| MMWHS [37] | 20/20 | 140/140 | 140/140 |
| AMOS22 [36] | 300/60 | 3,666/715 | 715/3,666 |
| Lesion-category CT–PET retrieval | |||
| Dataset | Source cases: CT/PET | CT→PET: Q/T | PET→CT: Q/T |
| HECKTOR-2025 [32] | 678/678 | 200/200 | 200/200 |
Table 11. Cohort sizes for the benchmark evaluations. Acquisition counts distinguish full manifests, sampled manifests, and source scans used for controlled resampling; each source scan contributes three spacing variants. Retrieval entries report query/target (Q/T) organ or lesion-category records per direction.
The same-scan construction is the anchor evidence: comparisons are made among variants derived from the same source image. Native-spacing analyses are built separately by assigning original scans to anisotropy bins: . The bins are near-isotropic [1.0, 1.5), moderately anisotropic [1.5, 3.0), and highly anisotropic [3.0, ). Because native-spacing bins contain different scans, they are interpreted only as observational support and not as the primary robustness claim. The controlled cohorts are smaller because source selection is constrained by native anisotropy: CT/CTA evaluation uses the available near-isotropic scans, while MR evaluation uses moderately anisotropic scans due to limited near-isotropic availability, summarized in Table 11.
Cross-Modal Anatomical Alignment Datasets
TotalSegmentator CT–MR, MMWHS, and AMOS22 provide 12, 7, and 13 shared organ classes, respectively. Organ records identify the source case, modality, anatomical label, image, and mask. The primary extraction crops the original organ bounding box with a five-voxel margin and retains surrounding image content; it therefore evaluates context-assisted organ retrieval, not purely organ-intrinsic features. Query and target pools are balanced by organ within each direction.
CHAOS uses eight queries and eight targets per direction under identifier-based liver pairing between different CT and MR patients (Section C.3); it is not pooled with multi-organ retrieval. The CT–PET extension uses HECKTOR-2025 primary-tumor and metastatic-lymph-node categories and excludes same-patient targets (Section D.8). These surfaces test retrieval under their declared label and modality definitions, not voxel-level registration or general modality invariance.
Anatomical Transfer Datasets
Anatomical Transfer uses TotalSegmentator CT–MR, MMWHS, and AMOS22. Every evaluated organ, including the target organ, receives two support samples per modality. Support cases are selected before constructing the query pool; all records from any support case are excluded from queries, across organs and modalities. Queries are then balanced by organ and modality. This is multiclass organ classification with both modalities represented in support and queries.
The reported cohorts contain 84, 18, and 53 query samples per organ and modality for TotalSegmentator, MMWHS, and AMOS22, respectively. With 12, 7, and 13 classes, these correspond to 48/2,016, 28/252, and 52/1,378 total support/query records. These support/query counts are consistent across evaluated encoders and feature interfaces. Case-disjoint evaluation does not establish that organ classes were absent from pretraining.
Benchmark Protocol and Metric Definitions
All benchmark encoders remain frozen, including when semantic-transfer classifiers or linear probes are fitted. Classifier training updates only the classifier, not the encoder. External comparisons use the same metric definitions but retain the checkpoint-specific input preprocessing and feature interfaces listed in Table 2; causal attribution to geometric pretraining is restricted to ISO/REL/SA triplets.
Frozen Feature Extraction
For 3DINO and Med3DINO, CLS is the final normalized class token, and GAP is the mean of final normalized patch tokens over spatial positions, preserving the feature channels. The resulting CLS and GAP vectors are then -normalized. Med3DINO evaluations use the registered 963crop checkpoints; other encoders retain their declared input and feature interfaces. BrainIAC uses its first patch token; OpenMind and MiM use global average pooling; VoCo pools multiscale features; SAM-Med3D pools post-neck features; MambaMIM pools its final-stage features; Hi-End-MAE and GL-MAE use CLS. These are frozen representations, not task-specific segmentation outputs.
Crop caches are shared only when their image preprocessing is identical. Embeddings remain separate by checkpoint, feature type, and intervention. Repeated evaluation reuses deterministic features when the cohort and preprocessing are unchanged; changing the evaluation seed does not require another encoder forward pass.
Acquisition Robustness Metrics
For a scan , a frozen encoder , and a deterministic preprocessing and resampling transform for target spacing , the controlled representation is
The controlled setting compares across spacing variants of the same scan.
Drift. For target spacings and , let and . Their cosine distance defines within-scan drift:
Lower drift means that the embedding of the same scan moves less under spacing perturbation. Drift is an individual-scan stability metric and does not by itself show whether the cohort-level feature geometry is preserved.
CKA. Centered kernel alignment (CKA) [7] is computed between feature matrices from two spacing variants over the same controlled sample set. Let denote the centered feature matrices for the same scans under two spacing variants, with rows corresponding to scans and columns to feature dimensions. Linear CKA follows
where denotes the Frobenius norm. Higher CKA indicates stronger preservation of cohort-level feature organization across spacing variants. Drift and CKA therefore provide complementary information: the former measures changes in individual embedding directions, whereas the latter measures preservation of centered cohort-level feature organization.
Semantic Transfer. For each source spacing and target spacing , classifiers are trained on frozen source-spacing features and tested on target-spacing features from held-out cases. Cases, semantic targets, five-fold splits, and classifier configuration are fixed across spacing comparisons. Standardization is fitted only on the source training fold and applied unchanged to the target test fold. Each eligible binary target uses logistic regression with lbfgs, , and at most 1,000 iterations, without warm-starting or condition-specific tuning. Folds use stratification when the target structure and class counts permit it, and otherwise use seeded shuffled splits. A binary target is evaluated in a fold only when the source training set and target test set each contain at least two positive and two negative examples.
Dataset-specific targets are defined in Table 12. For each directed spacing transfer, balanced accuracy is averaged over eligible targets within each fold and then across evaluated folds. The headline score averages the six directed transfers among the three spacing variants. It is not a common semantic score that can be pooled across datasets. The classifier-sensitivity analysis varies regularization and replaces logistic regression with nearest-centroid classification (Section D.3). These comparisons characterize recoverability under controlled resampling, not spacing effects independent of image interpolation or scanner physics.
| Dataset | Target definition |
| AbdomenAtlas | Binary presence of eligible structures from the annotation-label mapping. |
| KiTS23 | Kidney, tumor, and cyst presence candidates; only cyst presence is informative in the stored controlled cohort. |
| ImageCAS | One-versus-rest indicators for coronary-mask foreground-volume tertiles. |
| TS-MR | Structure presence from the individual segmentation masks. |
| JHU-Stroke | One-versus-rest indicators for lesion-mask foreground-volume tertiles. |
Table 12. Acquisition semantic-target definitions. Targets are derived from the original annotations and held fixed across spacing variants. Constant or unsupported targets are filtered before evaluation. Foreground-volume tertiles use foreground voxel counts in the source masks, not a common anatomical label vocabulary.
Cross-Modal Retrieval Metrics
For each query, candidates from the other modality are ranked by cosine similarity. Multi-organ pools contain equal target counts per organ, and positives share the query’s organ label. Let denote the candidate pool, its positive subset, and the candidate at rank . Then
Here, and denote source and target modalities, is the query set from modality , and is the fraction of positives among the first ranked candidates. The bidirectional score is . Top-1 and Top-5 measure whether any positive occurs within the first one or five candidates and use the same equal-direction averaging. CHAOS uses identifier-based liver pairing between different CT and MR patients; HECKTOR defines positives by lesion category after excluding same-patient targets. These evaluation settings are reported separately.
Anatomical Transfer Metrics
For each seed, support and query sets are balanced by class and modality and case-disjoint. The standardizer is fitted on support features only. Nearest-centroid classification assigns each standardized query to the closest support-class mean by Euclidean distance. The linear probe uses logistic regression with lbfgs, , and at most 2,000 iterations on the same standardized support set. Neither classifier changes the encoder.
Each class recall is measured on case-disjoint queries. Adaptation gain is computed within each seed before aggregation. Negative gains indicate that the fitted probe performs worse than nearest centroid on that evaluation split. This protocol evaluates limited-label organ classification.
Uncertainty and Paired Comparisons
Results report meansample SD over evaluation seeds 42, 123, and 456 for fixed checkpoints; scores and SDs are scaled by 100, and accuracy/retrieval differences are percentage points. Paired estimates and intervals refer to their corresponding cohorts and runs. REL–ISO, SA–ISO, and SA–REL use 50,000 bootstrap resamples (seed 2026). Acquisition and retrieval hierarchically resample seeds and paired units: scans for drift, scan rows with recomputed CKA, six directed spacing-transfer summaries for semantic transfer, and queries preserving equal retrieval-direction weights. Organ-classification intervals cross seeds and organ recalls. Primary intervals are centered and symmetric; classifier-sensitivity intervals are percentile-based. Bonferroni adjustment across the three contrasts within each dataset–feature–metric setting, and classifier where applicable, targets 95% family-wise coverage. Intervals containing zero establish neither separation nor equivalence. Uncertainty reflects evaluation randomness, not independent pretraining runs, and does not establish superiority over external encoders without corresponding paired tests.
Additional Benchmarking Results and Extended Tables
The main paper reports the primary acquisition, cross-modal retrieval, and organ transfer comparisons. Here, we provide the additional JHU-Stroke acquisition results and paired geometric-policy comparisons, followed by sensitivity analyses, organ- and direction-level breakdowns, spacing-severity comparisons, pretraining-unseen evaluation, and a CT–PET retrieval extension. Each analysis is interpreted within its stated dataset, feature interface, and protocol, using the metric and uncertainty definitions in Section C.
Acquisition Robustness Extensions
The supplementary acquisition results comprise JHU-Stroke performance in Table 13 and paired ISO/REL/SA comparisons across all five acquisition datasets in Table 14. The JHU-Stroke table complements the four-dataset main comparison and retains all evaluated encoders, including both CLS and GAP for 3DINO and Med3DINO. Within each evaluation run, drift averages the two reference-to-target comparisons, CKA averages the off-diagonal spacing comparisons, and semantic transfer averages the six directed source-to-target transfers. Semantic-transfer scores remain dataset-specific because their targets differ. Together, these analyses test whether geometric stability and semantic recoverability lead to the same policy comparisons across datasets and feature interfaces.
| Method | JHU-Stroke [30] | ||
| Drift↓ | CKA↑ | Semantic Transfer↑ | |
| External encoders | |||
| BrainIAC [15] | 1.30±0.00 | 99.80±0.00 | 59.90±2.14 |
| OpenMind [16] | 0.00±0.00 | 97.70±0.42 | 54.41±0.55 |
| VoCo [8] | 0.10±0.00 | 85.72±0.00 | 66.40±1.72 |
| 3DINO [1] (CLS) | 1.43±0.00 | 95.30±0.00 | 70.73±0.96 |
| 3DINO [1] (GAP) | 0.10±0.00 | 98.45±0.00 | 66.26±2.44 |
| SAM-Med3D [17] | 0.05±0.00 | 98.10±0.00 | 63.60±2.19 |
| Hi-End-MAE [18] | 0.09±0.00 | 98.89±0.00 | 60.57±1.90 |
| MambaMIM [19] | 0.04±0.00 | 98.98±0.00 | 58.50±0.52 |
| MiM [20] | 0.00±0.00 | 99.75±0.00 | 69.57±0.98 |
| GL-MAE [21] | 0.00±0.00 | 99.83±0.00 | 65.56±2.27 |
| Controlled Med3DINO: CLS | |||
| Med3DINO-ISO | 4.30±0.00 | 87.20±0.00 | 65.30±0.95 |
| Med3DINO-REL | 1.16±0.00 | 96.11±0.00 | 69.94±1.78 |
| Med3DINO-SA | 3.30±0.00 | 92.73±0.00 | 74.52±1.36 |
| Controlled Med3DINO: GAP | |||
| Med3DINO-ISO | 0.21±0.00 | 94.02±0.00 | 66.45±0.66 |
| Med3DINO-REL | 0.14±0.00 | 99.18±0.00 | 68.41±0.72 |
| Med3DINO-SA | 0.33±0.00 | 97.46±0.00 | 70.71±0.89 |
Table 13. Controlled same-scan acquisition robustness on JHU-Stroke. Entries are mean±SD over evaluation seeds (42,123,456) for fixed checkpoints; 0.00 may reflect rounding. Semantic transfer uses lesion-mask foreground-volume tertiles. External comparisons are contextual; geometric-policy attribution is restricted to ISO/REL/SA.
| Comparison | AbdomenAtlas [28] | KiTS23 [33] | ImageCAS [29] | TotalSegmentator-MR [34] | JHU-Stroke [30] |
| Drift↓ — CLS | |||||
| REL vs. ISO | +7.31 [6.96, 7.65] | +4.00 [3.03, 4.98] | -3.81 [-4.16, -3.47] | +0.33 [-0.19, 0.85] | +1.45 [1.26, 1.64] |
| SA vs. ISO | +0.09 [-0.25, 0.42] | -4.22 [-5.26, -3.17] | -18.45 [-18.90, -18.01] | +0.28 [-0.08, 0.65] | -3.43 [-3.69, -3.18] |
| SA vs. REL | -7.22 [-7.41, -7.02] | -8.22 [-8.83, -7.61] | -14.64 [-15.09, -14.20] | -0.05 [-0.54, 0.44] | -4.88 [-5.05, -4.72] |
| CKA↑ — CLS | |||||
| REL vs. ISO | +1.61 [1.39, 1.82] | -0.21 [-0.54, 0.13] | -10.36 [-11.11, -9.61] | -0.04 [-0.19, 0.11] | +0.68 [0.58, 0.78] |
| SA vs. ISO | +0.21 [-0.05, 0.46] | -0.99 [-1.35, -0.64] | -10.43 [-11.08, -9.77] | +0.34 [0.18, 0.51] | -3.08 [-3.57, -2.58] |
| SA vs. REL | -1.40 [-1.59, -1.21] | -0.79 [-1.03, -0.54] | -0.06 [-0.93, 0.81] | +0.38 [0.24, 0.52] | -3.75 [-4.25, -3.26] |
| Semantic transfer↑ — CLS | |||||
| REL vs. ISO | +3.72 [2.20, 4.59] | -7.80 [-10.78, -4.82] | +1.83 [1.03, 2.63] | +14.79 [13.42, 16.15] | +5.21 [3.56, 6.86] |
| SA vs. ISO | +7.06 [6.00, 8.12] | +3.58 [-1.34, 8.51] | +0.50 [-0.66, 1.67] | +19.01 [17.55, 20.47] | +3.50 [1.78, 5.22] |
| SA vs. REL | +3.71 [2.20, 5.22] | +11.39 [6.60, 16.17] | +1.33 [-2.64, -0.02] | +4.22 [3.26, 5.18] | -1.71 [-4.40, 0.98] |
Table 14. Paired ISO/REL/SA acquisition comparisons across five datasets. Entries are signed effects [Bonferroni-adjusted confidence intervals], scaled by 100. For A vs. B, effects are B − A for drift and A − B for CKA and transfer; positive values favor A, whereas negative values favor B. Intervals follow Section C.5 (50,000 bootstrap resamples; bootstrap seed 2026), with adjustment across the three contrasts within each dataset–feature–metric setting targeting 95% family-wise coverage. Bold entries exclude zero before rounding; intervals containing zero do not establish equivalence. Uncertainty reflects evaluation of fixed checkpoints, not independent pretraining runs.
On JHU-Stroke, REL has the lowest mean drift and highest mean CKA within both Med3DINO feature families, whereas SA has the highest mean semantic-transfer score. Near-zero reported drift among external encoders likewise does not identify the highest transfer score. These descriptive results motivate joint assessment of embedding stability and target recoverability; they do not establish pairwise significance across encoders.
For CLS features, the paired SA–REL comparisons favor REL for drift on four datasets, with no statistically supported difference on TS-MR. CKA favors REL on AbdomenAtlas, KiTS23, and JHU-Stroke, but SA on TS-MR; the ImageCAS interval includes zero. The paired semantic-transfer comparisons favor SA on AbdomenAtlas, KiTS23, and TS-MR, and REL on ImageCAS, with no statistically supported SA–REL difference on JHU-Stroke. Relative to ISO, SA has supported transfer advantages on AbdomenAtlas, TS-MR, and JHU-Stroke, with no statistically supported difference on KiTS23 or ImageCAS; REL improves transfer on all datasets except KiTS23, where ISO is favored.
Overall, these comparisons show that a policy can better stabilize embeddings without yielding better semantic transfer. Acquisition robustness therefore requires complementary assessment of within-scan drift, cohort-level geometry, and recoverability of the specified targets; no single metric supports a uniform policy ranking.
Semantic-Target Sensitivity
We test whether the distinction between geometric stability and semantic recoverability is driven by foreground-volume-tertile targets. We restrict the semantic-transfer comparison to annotation-derived targets in AbdomenAtlas, KiTS23, and TS-MR, excluding the ImageCAS and JHU-Stroke foreground-volume-tertile targets. This is a restriction of the dataset set, not a replacement of the classifiers or labels within a retained dataset.
For CLS, the paired SA–REL advantages are 3.7 [2.2, 5.2], 11.4 [6.6, 16.2], and 4.2 [3.3, 5.2] percentage points, respectively (Table 14). Each adjusted interval excludes zero. REL retains lower drift on AbdomenAtlas and KiTS23, while CKA depends on the dataset. Thus, SA’s semantic-transfer advantage persists on these retained datasets even where REL provides lower drift: the stability–recoverability distinction does not depend solely on volume-tertile targets. It remains a property-specific comparison; heterogeneous semantic targets are not pooled into one cross-dataset transfer score.
Classifier Sensitivity
We examine whether semantic-transfer and anatomical transfer comparisons depend on classifier choice (Table 15). Within this sensitivity analysis, features, cases, targets, partitions, and training-only standardization remain fixed across classifier settings for each checkpoint. We vary logistic regression’s inverse regularization strength, , and compare it with nearest-centroid classification, which requires no iterative optimization. For each binary semantic target, positive and negative centroids are computed from standardized source-training features; target-spacing test features are classified by Euclidean distance to these centroids. The table reports all three pairwise contrasts for and nearest centroid. The baselines are recomputed using the benchmark protocol and verified against its evaluation routines, rather than taken from the original estimates retained in the main tables.
| Dataset | Feature | Comparison | Logistic (pp) [CI] | Nearest centroid (pp) [CI] |
| Semantic transfer | ||||
| AbdomenAtlas | CLS | REL–ISO | +3.30 [2.21, 4.57] | +5.53 [4.90, 6.28] |
| SA–ISO | +6.82 [5.41, 8.41] | +7.23 [6.52, 8.01] | ||
| SA–REL | +3.52 [1.79, 5.53] | +1.71 [1.48, 1.96] | ||
| AbdomenAtlas | GAP | REL–ISO | +5.33 [2.61, 7.70] | +9.22 [8.23, 10.19] |
| SA–ISO | +7.32 [5.15, 9.15] | +10.64 [9.56, 11.83] | ||
| SA–REL | +1.99 [1.23, 3.02] | +1.42 [1.21, 1.69] | ||
| KiTS23 | CLS | REL–ISO | −8.52 [−13.19, −2.82] | −6.35 [−8.32, −4.15] |
| SA–ISO | +3.98 [1.06, 6.82] | −3.43 [−9.62, 2.59] | ||
| SA–REL | +12.50 [6.90, 16.84] | +2.92 [−2.00, 7.84] | ||
| KiTS23 | GAP | REL–ISO | +7.66 [1.87, 14.45] | +0.68 [−4.38, 5.00] |
| SA–ISO | +5.02 [1.33, 8.61] | +1.02 [−4.79, 6.65] | ||
| SA–REL | −2.64 [−7.33, 0.32] | +0.33 [−1.83, 2.59] | ||
| TS-MR | CLS | REL–ISO | +12.68 [11.66, 13.49] | +10.93 [9.78, 12.14] |
| SA–ISO | +17.21 [15.99, 18.12] | +15.38 [14.32, 16.15] | ||
| SA–REL | +4.53 [3.85, 5.09] | +4.44 [3.49, 5.36] | ||
| TS-MR | GAP | REL–ISO | +16.06 [14.86, 17.46] | +15.80 [14.02, 18.13] |
| SA–ISO | +19.17 [17.86, 20.44] | +20.47 [19.10, 21.97] | ||
| SA–REL | +3.11 [2.09, 4.43] | +4.67 [3.62, 5.46] | ||
| Anatomical transfer | ||||
| TotalSeg CT–MR | CLS | REL–ISO | +7.82 [1.25, 13.69] | +9.80 [3.77, 15.56] |
| SA–ISO | +9.18 [1.24, 16.54] | +11.09 [2.40, 19.35] | ||
| SA–REL | +1.36 [1.76, 7.63] | +1.29 [0.13, 7.95] | ||
| TotalSeg CT–MR | GAP | REL–ISO | +29.20 [20.29, 38.83] | +32.54 [25.30, 39.50] |
| SA–ISO | +33.99 [24.26, 44.21] | +35.85 [26.74, 45.09] | ||
| SA–REL | +4.79 [0.31, 9.31] | +3.31 [2.37, 7.69] | ||
| MMWHS | CLS | REL–ISO | +9.66 [−0.79, 21.03] | +12.04 [2.91, 22.35] |
| SA–ISO | +11.77 [3.31, 22.62] | +13.10 [4.89, 23.02] | ||
| SA–REL | +2.12 [−10.71, 15.21] | +1.06 [−8.07, 12.70] | ||
| MMWHS | GAP | REL–ISO | +36.51 [28.57, 46.16] | +41.01 [27.65, 53.17] |
| SA–ISO | +39.15 [28.97, 50.40] | +44.97 [29.23, 60.85] | ||
| SA–REL | +2.65 [1.97, 10.32] | +3.97 [2.69, 12.30] | ||
| AMOS22 | CLS | REL–ISO | +12.34 [3.31, 21.83] | +12.60 [3.51, 22.21] |
| SA–ISO | +16.35 [6.36, 26.05] | +16.93 [7.01, 26.63] | ||
| SA–REL | +4.02 [2.10, 10.30] | +4.33 [3.23, 9.87] | ||
| AMOS22 | GAP | REL–ISO | +37.69 [27.55, 49.61] | +41.63 [31.47, 51.52] |
| SA–ISO | +44.22 [34.33, 55.81] | +50.05 [39.99, 60.30] | ||
| SA–REL | +6.53 [2.25, 11.66] | +8.42 [1.98, 13.74] |
Table 15. Classifier sensitivity of semantic and anatomical transfer. For each comparison –, entries report in percentage points (pp) over evaluation seeds 42, 123, and 456. Positive effects favor the first checkpoint (); negative effects favor the second (). Brackets give Bonferroni-adjusted 95% bootstrap confidence intervals (50,000 resamples), with adjustment across REL–ISO, SA–ISO, and SA–REL within each module–dataset–feature–classifier setting. Intervals containing zero establish neither separation nor equivalence.
Regularization changes preserve the mean ISO/REL/SA ordering across all six dataset–feature combinations in each module. Nearest-centroid classification preserves that ordering in four of six semantic-transfer combinations and all six anatomical-transfer combinations. The semantic ordering changes only on KiTS23; AbdomenAtlas and TS-MR retain SA REL ISO, with positive adjusted intervals for all three contrasts under both classifiers and both feature types. In anatomical transfer, adjusted intervals favor SA over ISO throughout and REL over ISO except for MMWHS–CLS with logistic regression. Across the three organ transfer datasets, two feature types, and two classifiers, SA also achieves higher mean accuracy than REL in all twelve settings, with positive adjusted intervals in ten. The two unresolved SA–REL comparisons are MMWHS–CLS with logistic regression and nearest centroid. Thus, the mean accuracy ordering is consistent across classifiers, while statistical separation remains comparison-specific.
Support-Budget Sensitivity
To test whether the organ transfer comparison depends on the two-sample support budget, we evaluate CLS probe BA at one, two, four, and eight support samples per organ and modality, using case-disjoint sampling shared across checkpoints within each budget. Table 16 averages dataset scores with equal weight. This additional sweep evaluates support-budget dependence separately from the estimates retained in the main table. We stop at eight shots, which retains 12 MMWHS query cases per organ and modality; larger budgets further reduce the query pool. Query cases change as support increases, so comparisons are controlled within each budget rather than isolating the gain from additional support across rows.
| Support | 3DINO/REL/SA probe BA | SA highest mean | Query cases: TS/MMWHS/AMOS22 |
| 1 | 54.8/55.3/56.4 | 1/3 | 85/19/54 |
| 2 | 64.7/66.1/68.7 | 3/3 | 84/18/53 |
| 4 | 71.2/75.1/77.5 | 3/3 | 82/16/51 |
| 8 | 76.9/80.0/81.5 | 3/3 | 77–78/12/47 |
Table 16. CLS organ transfer support-budget sweep. Probe BA is averaged over seeds (42,123,456) and then equally over TotalSegmentator CT–MR, MMWHS, and AMOS22; values are ×100. The third column counts datasets on which SA has the highest mean. Query counts are per organ and modality.
The mean ordering is SA > REL > 3DINO throughout. At one shot, SA has the highest mean on one of the three datasets; at two, four, and eight shots, it has the highest mean on every dataset. SA’s aggregate mean advantage is thus not confined to the primary two-sample budget, while its dataset-level lead becomes consistent only at the tested budgets of two or more samples per organ and modality.
Protocol Stability
We test whether policy rankings depend on how the evaluation inputs and anatomical categories are defined. We vary acquisition preprocessing, organ-region definition, and organ-label granularity while holding the evaluated checkpoint and the eligible cohort fixed within each analysis. The controlled comparisons use ISO, REL, and SA; the main ranking summary uses CLS. Table 18 compares each altered protocol with its specified reference. Kendall’s measures agreement of the complete three-checkpoint ordering (1 means identical ordering); leader retention counts settings in which the reference winner remains first. These quantities describe ranking stability, not invariance of absolute scores or statistical equivalence of checkpoints.
| Controlled change | Mean Kendall | Reference leader retained |
| Disable anti-aliasing | 0.82 | 51/54 (94%) |
| Trilinear → nearest | 0.73 | 48/54 (89%) |
| Centered fixed physical FOV | 0.70 | 46/54 (85%) |
| Fine-organ → organ-family labels | 0.78 | 5/6 (83%) |
| Organ-only M5 → 1-mm mask erosion | 0.89 | 5/6 (83%) |
Table 18.
Acquisition and preprocessing. To assess dependence on the resampling pipeline and physical coverage, we vary preprocessing while retaining the same scans. AbdomenAtlas, KiTS23, and TS-MR are evaluated for drift, CKA, and semantic transfer at the moderate and severe target conditions. We separately disable anti-aliasing, replace trilinear interpolation with nearest-neighbor interpolation, or use a centered physical FOV of mm. Other protocol settings remain fixed. The 54 comparisons are three datasets three metrics two target conditions three evaluation seeds. Moderate and severe refer to each dataset’s predefined target spacings, not common absolute scanner settings.
Region definition. The margin and masking interventions distinguish dependence on crop extent from dependence on surrounding image content; erosion further tests sensitivity to image content near the organ boundary. AMOS22 and MMWHS use five predefined crop surfaces: the original bounding box with a five-voxel margin and retained context (M5), a zero-margin box with retained context (M0), the same two boxes with outside-organ content zeroed, and an organ-only M5 crop with a 1-mm erosion. Margins alter crop extent and surrounding context, not the original organ mask. Erosion is defined by mm, with the physical voxel spacing , and is applied
Table 17: Crop-margin and context sensitivity on AMOS22 and MMWHS. The reported CLS analysis uses seeds 42, 123, and 456; scores are equal-weight dataset means , in ISO/REL/SA order. Pairwise entries are SA–REL differences in percentage points with dataset-stratified, Bonferroni-adjusted 95% intervals across the three checkpoint comparisons. M5/M0 denote five-/zero-voxel margins.
Table 18: CLS ISO/REL/SA ranking stability over seeds 42, 123, and 456. Acquisition rows average 54 seed-specific dataset–metric–severity comparisons. Organ granularity and erosion use six dataset–metric comparisons after averaging seeds: AMOS22/MMWHS mAP/Top-1/probe BA. Each row uses its own reference; erosion is compared with unmodified organ-only M5 masks. Retention percentages are rounded from the displayed counts. M5 denote 5-voxel margins.
before axis permutation. The bounding box always comes from the original mask; erosion changes only the image content retained inside it. Original masks contain at least 100 voxels and transformed masks must remain nonempty, preserving the manifest cohort.
Sampling plans store exact bidirectional query/target IDs and case-disjoint support/query IDs and are shared across the three checkpoints and crop surfaces for each seed. Table 17 reports the crop-margin and context comparisons.
| Surface | mAP: ISO/REL/SA | SA–REL | Top-1: ISO/REL/SA | SA–REL |
| M5 + context | 15.3/33.2/42.7 | +9.5 [8.6, 10.4] | 14.8/44.5/60.5 | +16.0 [13.3, 18.7] |
| M0 + context | 15.5/31.5/40.4 | +8.8 [7.8, 9.8] | 12.9/38.7/52.1 | +13.4 [10.8, 16.1] |
| M5 + organ-only | 16.7/24.0/26.4 | +2.4 [1.6, 5.4] | 18.6/27.9/31.8 | +3.9 [1.7, 6.1] |
| M0 + organ-only | 17.8/22.2/23.7 | +1.5 [0.6, 2.6] | 18.9/31.3/32.5 | +1.2 [1.0, 2.5] |
Table 17.
All four margin/context settings retain the mean ordering SA REL ISO for mAP and Top-1 (Table 17). Masking context lowers the REL and SA scores and narrows their differences, but all adjusted SA–REL intervals remain positive. Thus, SA’s advantage persists within the organ-only crop construction, while its magnitude depends on surrounding context; though stable ordering does not imply context-independent representations. The 1-mm erosion retains five of six reference leaders with mean Kendall’s ; only the MMWHS probe BA leader changes from REL to ISO (Table 18). This supports stability under the tested boundary change, rather than invariance to mask definition.
Organ granularity. The Fine-organ → organ-family labels row in Table 18 tests whether the ISO/REL/SA ranking persists when left/right distinctions are removed from the evaluation labels. We reuse the baseline features without additional image processing or encoder inference. In AMOS22, left/right kidneys and adrenal glands are merged into kidney and adrenal-gland classes, reducing 13 classes to 11. In MMWHS, left/right atria and ventricles are merged into atrium and ventricle, reducing seven classes to five. Other labels and source-case identifiers remain unchanged. At most one crop per source case, class, and modality is retained before balanced sampling, preventing merged laterality labels from duplicating a patient’s contribution. This tests a defined laterality collapse, not arbitrary organ-system groupings.
Raw fine-to-family score increases are not interpreted as improved representations because fewer classes change retrieval and classification difficulty. We therefore compare checkpoint rankings within each label definition rather than treating higher coarse-label scores as gains from pretraining.
This row aggregates mAP, Top-1, and probe balanced-accuracy rankings on AMOS22 and MMWHS after averaging metric scores over evaluation seeds. The reference leader is retained in five of these six dataset–metric comparisons, with mean Kendall’s . Most leading-policy conclusions therefore persist after removing laterality distinctions, but the remaining leader change and imperfect ordering agreement show that label granularity can affect the comparative conclusion.
Together, the ablations support stability of most leading-policy conclusions under the tested changes, while the crop/context results show that stable rankings can coexist with changes in scores and effect sizes. Crop/context, interpolation, FOV, and label definitions therefore remain part of the benchmark specification rather than interchangeable implementation choices. Controlled resampling does not simulate scanner physics or the full variability of clinical acquisition.
Organ, Modality-Direction, and Spacing-Severity Analysis
We analyze CLS SA–REL effects from the additional frozen-feature evaluations separately from the estimates retained in the main tables. Table 19 resolves spacing severity and retrieval direction; severity-specific semantic transfer compares reference spacing with each moderate or severe target, rather than averaging all six transfer directions. Averaged equally across the five acquisition datasets, REL has lower mean drift and higher mean CKA at both target severities. Semantic transfer favors SA on AbdomenAtlas, KiTS23, and TS-MR at both severities, REL on ImageCAS, and changes direction on JHU-Stroke. Thus, the semantic-transfer advantage remains dataset-specific at each controlled spacing severity.
| Condition | Drift | CKA | Transfer: signed SA–REL effect |
| Acquisition: controlled spacing severity | |||
| Moderate | REL +6.6 | REL +1.4 | AbdomenAtlas +2.8; KiTS23 +4.8; TS-MR +4.0; ImageCAS −2.8; JHU −3.9 |
| Severe | REL +7.5 | REL +0.7 | AbdomenAtlas +1.1; KiTS23 +11.6; TS-MR +4.7; ImageCAS −3.0; JHU +1.1 |
| Retrieval: modality direction and organ-level counts | |||
| Dataset | CTMR mAP | MRCT mAP | |
| AMOS22 | SA +4.9; SA higher on 8/13 organs | SA +4.3; SA higher on 10/13 organs | |
| MMWHS | SA +3.9; SA higher on 5/7 organs | REL +1.4; SA higher on 4/7 organs |
Table 19. CLS SA–REL effects over seeds 42, 123, and 456. A named checkpoint followed by + denotes its advantage in the metric’s preferred direction: for example, REL +6.6 is 6.6 points lower drift. Scores are scaled by 100. Acquisition drift and CKA are equal-weight five-dataset means; semantic transfer remains dataset-specific. Moderate/severe are controlled resampling targets, not measured scanner categories. Retrieval counts denote organs with higher SA mean mAP and are descriptive, not significance counts.
For retrieval, SA has higher mean mAP in both AMOS22 directions and in MMWHS CTMR; REL is higher in MMWHS MRCT. In the latter direction, SA leads on four of seven organs, but REL’s larger gains on the other organs determine the aggregate. Organ counts therefore complement, rather than replace, the magnitude of the mean difference. Table 20 reports every organ-level difference.
| Organ | CT→MR | MR→CT | Organ | CT→MR | MR→CT |
| Adrenal gland left | −4.96 | +9.65 | Ascending aorta | +6.23 | −25.40 |
| Adrenal gland right | −18.84 | +5.49 | Left atrium | +15.77 | +12.27 |
| Aorta | +21.37 | +11.41 | Left ventricle | +1.45 | +10.15 |
| Duodenum | −2.60 | −0.11 | Myocardium | −1.31 | +6.18 |
| Esophagus | +14.99 | +15.53 | Pulmonary artery | −5.04 | +4.72 |
| Gallbladder | −9.30 | +2.43 | Right atrium | +0.95 | −16.86 |
| Inferior vena cava | +29.50 | +7.36 | Right ventricle | +9.53 | −0.56 |
| Kidney left | +13.81 | +2.74 | |||
| Kidney right | +8.61 | +3.94 | |||
| Liver | +4.82 | +1.51 | |||
| Pancreas | +4.60 | +4.22 | |||
| Spleen | +5.46 | −5.36 | |||
| Stomach | −3.24 | −2.47 |
Table 20. Complete CLS organ-level SA–REL mAP differences, averaged over seeds 42, 123, and 456 and expressed in percentage points. Positive values favor SA; negative values favor REL. These are descriptive mean differences without per-organ significance claims. The equal-organ means reproduce the directional effects in Table 19.
The organ-level results clarify the MMWHS direction reversal: the ascending aorta and right atrium favor SA in CTMR but show larger REL-favoring differences in MRCT. These differences outweigh the positive SA effects on four other organs in that direction. Together with the dataset-specific severity patterns, this shows why neither a bidirectional mean nor a count of favorable organs fully describes the policy comparison. These descriptive breakdowns identify where SA helps and where it does not; they do not establish that spacing sensitivity causes cross-modal performance.
Pretraining-Unseen Evaluation
We examine whether the policy comparisons extend to datasets absent from Med3DINO pretraining. The exposure-restricted comparison includes KiTS23 and TS-MR for Acquisition Robustness, and MMWHS and AMOS22 for cross-modal and anatomical transfer. TotalSegmentator CT–MR is excluded because its CT component is pretraining-seen; HECKTOR is also pretraining-seen and is not included. CHAOS is kept separate because its identifier-based liver pairing between different CT and MR patients is not comparable to organ-category retrieval. No corresponding unseen-pretraining claim is made for external encoders whose training-data exposure differs.
Table 21 summarizes the reported restricted analysis. Ranks order only ISO/REL/SA within each dataset and metric and then average equally across the two datasets. Paired wins require a Bonferroni-adjusted interval excluding zero. The table separates mean ordering from paired evidence and does not combine metrics into a global ranking. Its paired outcomes belong to this restricted analysis, rather than being substituted for intervals from the primary or classifier-sensitivity evaluations.
| Metric | ISO/REL/SA mean rank ↓ | SA–REL outcomes |
| Acquisition drift | 2.5/1.0/2.5 | REL 1; NS 1 |
| Acquisition CKA | 1.5/2.5/2.0 | REL 1; SA 1 |
| Acquisition transfer | 2.5/2.5/1.0 | SA 2 |
| Cross-modal mAP | 3.0/2.0/1.0 | SA 2 |
| Cross-modal Top-1 | 3.0/2.0/1.0 | SA 2 |
| Linear probe BA | 3.0/2.0/1.0 | SA 2 |
Table 21. Reported CLS pretraining-unseen summary over seeds 42, 123, and 456. Rank 1 is best; mean ranks give equal weight to the two eligible datasets for each module. The last column counts supported SA–REL outcomes out of two datasets. NS (Not Supported) denotes an adjusted interval containing zero, not equivalence.
Within this restricted analysis, SA ranks first for cross-modal mAP, Top-1, and probe BA, with adjusted SA–REL intervals favoring SA on both eligible datasets for each metric (Table 21). Acquisition outcomes remain metric-specific: REL has the best average drift rank, with a supported advantage on one dataset and no supported separation on the other; CKA favors REL on KiTS23 and SA on TS-MR, while semantic transfer favors SA on both datasets. SA’s advantages in retrieval and probe BA therefore extend to these pretraining-unseen datasets, rather than depending exclusively on pretraining-seen collections.
CT–PET Retrieval Extension
CT–MR provides the primary shared multi-organ evaluation, but the retrieval protocol only requires a defined target vocabulary supported in both modalities. To test its applicability to another modality pair and label vocabulary, we evaluate HECKTOR-2025 [32] CT–PET with two categories: primary tumor and metastatic lymph nodes. Masks are mapped into each modality’s physical image grid with nearest-neighbor label interpolation. Query and target pools are balanced by category, and every target from the query patient’s case is excluded. Retrieval therefore cannot succeed by directly matching a patient’s registered CT/PET pair. Encoders remain frozen, and CT→PET and PET→CT scores are averaged equally.
From 678 complete CT/PET pairs, we select 500 category-balanced crops representing 229 patients. Each category contributes 125 crops per modality; each retrieval direction samples 100 queries and 100 targets per category, totaling 200 queries and 200 targets. After same-patient exclusion, queries retain 198–200 candidate targets.
Table 22 reports higher mean mAP and Top-1 for SA than REL and ISO with both feature types. The agreement across CLS and GAP supports a consistent descriptive SA advantage in this cross-patient lesion-category task. For these patient-excluded pools, random ranking has expected mAP/Top-1 of 51.07/49.83 on the reported scale. Scores are interpreted relative to this reference and are not pooled with multi-organ CT–MR results. The HECKTOR resource is pretraining-seen for Med3DINO. These results extend the retrieval evaluation beyond CT–MR and organ labels, without establishing general modality invariance.
| Feature | ISO (mAP/Top-1) | REL (mAP/Top-1) | SA (mAP/Top-1) |
| CLS | |||
| GAP |
Table 22. HECKTOR-2025 balanced lesion-category CTPET retrieval. Entries are mAP/Top-1, expressed as meansample SD over seeds 42, 123, and 456 and scaled by 100.
Implementation and Reproducibility
REFORM-3D is provided as a standalone Python package, with the benchmark implementation under src/reform3d/.
Experiment Identification and Resources
Each evaluation is specified by its dataset and sampled cohort, checkpoint, frozen-feature interface, preprocessing, task settings, and evaluation seed. Dataset construction and metric definitions are given in Sections B and C; additional evaluation settings are specified in Section D. Reproducing a reported comparison requires its corresponding manifests, checkpoint weights, and configuration.
Table 23 summarizes the repository’s implementation and reproducibility resources. YAML configurations specify evaluation inputs; reform3d check validates them, and reform3d run executes the configured modules. External encoders retain their declared preprocessing and frozen-feature interfaces. Installation instructions, configuration examples, and encoder-specific requirements are documented in the repository.
| Resource | Repository artifact | Role |
| Data and cohorts | docs/data.md; src/reform3d/prepare.py | Dataset inputs, manifest preparation, and cohort validation. |
| Evaluation | src/reform3d/cli.py; configs/ | Configured input validation and module execution. |
| Encoders | reproduction/checkpoints.json; docs/encoders.md | Checkpoint identities, available weight hashes, interfaces, and dependencies. |
| Environment | requirements.txt; pyproject.toml | Tested dependency versions and package installation. |
| Usage | docs/usage.md | Configuration, cache reuse, outputs, and failure handling. |
Table 23. Implementation and reproducibility resources in the REFORM-3D repository. Paths are relative to the repository root.
Manifests, Caches, and Outputs
Manifests record eligible source images, anatomical targets, modalities, and source-case identifiers. The YAML seeds field selects repeated evaluations, with results stored under runs/<run_name>/seeds/seed_<N>/. Shared deterministic crop caches avoid repeated image preprocessing. Checkpoint- and feature-specific bundles remain isolated, and sensitivity bundles additionally record manifest and preprocessing signatures. Before reusing completed features or metrics, the standalone runner verifies configuration compatibility and their recorded SHA-256 checksums.
Region-definition and organ-granularity experiments save reusable sampling plans, verify unique sample IDs and exact cohort coverage, and reject incomplete bundles before aggregation. Their analyses retain query/organ-level records for reconstructing headline metrics and paired effects.
Data Access and Release Documentation
The source inventory in Section A.1 describes corpus composition; it does not authorize redistribution of provider-controlled scans or annotations. Users must obtain restricted sources from their original providers under the applicable terms. Reconstruction scripts operate on locally obtained data, and any redistribution of derived assets remains subject to those source terms.
Release documentation will specify dataset versions, cohort-selection rules, organ mappings, evaluation seeds, checkpoint sources, applicable terms, and available SHA-256 hashes. Croissant metadata and a responsible-AI (RAI) benchmark card will document dataset composition, pretraining exposure, intended use, access constraints, and limitations.
Compute Accounting
The controlled Med3DINO comparison uses the common 125K-update pretraining budget. Evaluation separates image preprocessing, frozen-feature extraction, and CPU classifier/statistical analysis. Features are reused across evaluation seeds when their cohort and preprocessing are unchanged; organ-granularity analysis reuses baseline features without additional encoder inference. Pretraining was conducted on a 16-node cluster with four NVIDIA A100 GPUs per node, with a training duration of eight days per checkpoint. Evaluation used two NVIDIA A100 GPUs and typically required 1–2 days per dataset, depending on dataset size and evaluation protocol.
Downstream Segmentation Protocol
For downstream segmentation, we keep the pretrained encoder frozen and train a ViTAdapterUNETR decoder, following 3DINO [1] with each dataset’s labeled training set. Training uses AdamW with an initial learning rate of and a warmup-cosine schedule for 100 epochs, with early stopping after 30 validation evaluations without improvement. Crop dimensions, batch size, and iterations per epoch follow the dataset-specific run settings. Most datasets use combined Dice and cross-entropy loss; BraTS-GLI and ISLES22 use sigmoid Dice loss. We select the checkpoint with the highest validation Dice and evaluate it on the test split using sliding-window inference. Dice is averaged over test scans, while HD95 aggregation excludes non-finite per-scan values.
NeurIPS Paper Checklist
The checklist is designed to encourage best practices for responsible machine learning research, addressing issues of reproducibility, transparency, research ethics, and societal impact. Do not remove the checklist: The papers not including the checklist will be desk rejected. The checklist should follow the references and follow the (optional) supplemental material. The checklist does NOT count towards the page limit.
Please read the checklist guidelines carefully for information on how to answer these questions. For each question in the checklist:
You should answer [Yes], [No], or [N/A].
[N/A] means either that the question is Not Applicable for that particular paper or the relevant information is Not Available.
Please provide a short (1–2 sentence) justification right after your answer (even for [N/A]).
The checklist answers are an integral part of your paper submission. They are visible to the reviewers, area chairs, senior area chairs, and ethics reviewers. You will also be asked to include it (after eventual revisions) with the final version of your paper, and its final version will be published with the paper.
The reviewers of your paper will be asked to use the checklist as one of the factors in their evaluation. While [Yes] is generally preferable to [No], it is perfectly acceptable to answer [No] provided a proper justification is given (e.g., error bars are not reported because it would be too computationally expensive” or “we were unable to find the license for the dataset we used”). In general, answering [No] or [N/A] is not grounds for rejection. While the questions are phrased in a binary way, we acknowledge that the true answer is often more nuanced, so please just use your best judgment and write a justification to elaborate. All supporting evidence can appear either in the main paper or the supplemental material, provided in appendix. If you answer [Yes] to a question, in the justification please point to the section(s) where related material for the question can be found.
IMPORTANT, please:
Delete this instruction block, but keep the section heading “NeurIPS Paper Checklist”,
Keep the checklist subsection headings, questions/answers and guidelines below.
Do not modify the questions and only use the provided macros for your answers.
Claims
Question: Do the main claims made in the abstract and introduction accurately reflect the paper’s contributions and scope?
Answer: [Yes]
Justification: The abstract and introduction state the paper’s core contributions: REFORM-3D as a representation-centric framework comprising Acquisition Robustness, Cross-Modal Anatomical Alignment, and Anatomical Transfer; Med3DINO encoders under controlled geometric pretraining regimes; and benchmarking across encoder families. Sections 3 and 4 document the corresponding methods and results. Geometric-policy attribution is restricted to the controlled Med3DINO comparison, while external encoders provide contextual comparisons.
Guidelines:
The answer [N/A] means that the abstract and introduction do not include the claims made in the paper.
The abstract and/or introduction should clearly state the claims made, including the contributions made in the paper and important assumptions and limitations. A [No] or [N/A] answer to this question will not be perceived well by the reviewers.
The claims made should match theoretical and experimental results, and reflect how much the results can be expected to generalize to other settings.
It is fine to include aspirational goals as motivation as long as it is clear that these goals are not attained by the paper.
Limitations
Question: Does the paper discuss the limitations of the work performed by the authors?
Answer: [Yes]
Justification: Section 5 discusses the evaluated representation settings and clarifies that REFORM-3D neither establishes broader invariance nor replaces downstream evaluation. It identifies controlled resampling as geometric stress testing rather than full clinical acquisition realism, and limits the REL–SA findings to the studied architecture and self-supervised objective.
Guidelines:
The answer [N/A] means that the paper has no limitation while the answer [No] means that the paper has limitations, but those are not discussed in the paper.
The authors are encouraged to create a separate “Limitations” section in their paper.
The paper should point out any strong assumptions and how robust the results are to violations of these assumptions (e.g., independence assumptions, noiseless settings, model well-specification, asymptotic approximations only holding locally). The authors should reflect on how these assumptions might be violated in practice and what the implications would be.
The authors should reflect on the scope of the claims made, e.g., if the approach was only tested on a few datasets or with a few runs. In general, empirical results often depend on implicit assumptions, which should be articulated.
The authors should reflect on the factors that influence the performance of the approach. For example, a facial recognition algorithm may perform poorly when image resolution is low or images are taken in low lighting. Or a speech-to-text system might not be used reliably to provide closed captions for online lectures because it fails to handle technical jargon.
The authors should discuss the computational efficiency of the proposed algorithms and how they scale with dataset size.
If applicable, the authors should discuss possible limitations of their approach to address problems of privacy and fairness.
While the authors might fear that complete honesty about limitations might be used by reviewers as grounds for rejection, a worse outcome might be that reviewers discover limitations that aren’t acknowledged in the paper. The authors should use their best judgment and recognize that individual actions in favor of transparency play an important role in developing norms that preserve the integrity of the community. Reviewers will be specifically instructed to not penalize honesty concerning limitations.
Theory assumptions and proofs
Question: For each theoretical result, does the paper provide the full set of assumptions and a complete (and correct) proof?
Answer: [N/A]
Justification: The paper does not include theoretical results such as theorems or formal proofs. It focuses on defining an evaluation framework, associated metrics, and empirical benchmarking protocols for analyzing frozen 3D representations.
Guidelines:
The answer [N/A] means that the paper does not include theoretical results.
All the theorems, formulas, and proofs in the paper should be numbered and cross-referenced.
All assumptions should be clearly stated or referenced in the statement of any theorems.
The proofs can either appear in the main paper or the supplemental material, but if they appear in the supplemental material, the authors are encouraged to provide a short proof sketch to provide intuition.
Inversely, any informal proof provided in the core of the paper should be complemented by formal proofs provided in appendix or supplemental material.
Theorems and Lemmas that the proof relies upon should be properly referenced.
Experimental result reproducibility
Question: Does the paper fully disclose all the information needed to reproduce the main experimental results of the paper to the extent that it affects the main claims and/or conclusions of the paper (regardless of whether the code and data are provided or not)?
Answer: [Yes]
Justification: Sections A, B, and C specify the pretraining settings, evaluation cohorts, preprocessing, classifiers, and metrics. Section E identifies the executable framework, configurations, checkpoint records, and input artifacts required to reproduce the corresponding evaluations.
Guidelines:
The answer [N/A] means that the paper does not include experiments.
If the paper includes experiments, a [No] answer to this question will not be perceived well by the reviewers: Making the paper reproducible is important, regardless of whether the code and data are provided or not.
If the contribution is a dataset and/or model, the authors should describe the steps taken to make their results reproducible or verifiable.
Depending on the contribution, reproducibility can be accomplished in various ways. For example, if the contribution is a novel architecture, describing the architecture fully might suffice, or if the contribution is a specific model and empirical evaluation, it may be necessary to either make it possible for others to replicate the model with the same dataset, or provide access to the model. In general. releasing code and data is often one good way to accomplish this, but reproducibility can also be provided via detailed instructions for how to replicate the results, access to a hosted model (e.g., in the case of a large language model), releasing of a model checkpoint, or other means that are appropriate to the research performed.
While NeurIPS does not require releasing code, the conference does require all submissions to provide some reasonable avenue for reproducibility, which may depend on the nature of the contribution. For example (a) If the contribution is primarily a new algorithm, the paper should make it clear how to reproduce that algorithm. (b) If the contribution is primarily a new model architecture, the paper should describe the architecture clearly and fully. (c) If the contribution is a new model (e.g., a large language model), then there should either be a way to access this model for reproducing the results or a way to reproduce the model (e.g., with an open-source dataset or instructions for how to construct the dataset). (d) We recognize that reproducibility may be tricky in some cases, in which case authors are welcome to describe the particular way they provide for reproducibility. In the case of closed-source models, it may be that access to the model is limited in some way (e.g., to registered users), but it should be possible for other researchers to have some path to reproducing or verifying the results.
Open access to data and code
Question: Does the paper provide open access to the data and code, with sufficient instructions to faithfully reproduce the main experimental results, as described in supplemental material?
Answer: [Yes]
Justification: The REFORM-3D code and Med3DINO checkpoints are publicly available. Section E describes the standalone framework and execution resources. Provider-controlled images and annotations must be obtained from their original sources under the applicable access terms.
Guidelines:
The answer [N/A] means that paper does not include experiments requiring code.
Please see the NeurIPS code and data submission guidelines (https://neurips.cc/public/guides/CodeSubmissionPolicy) for more details.
While we encourage the release of code and data, we understand that this might not be possible, so [No] is an acceptable answer. Papers cannot be rejected simply for not including code, unless this is central to the contribution (e.g., for a new open-source benchmark).
The instructions should contain the exact command and environment needed to run to reproduce the results. See the NeurIPS code and data submission guidelines (https://neurips.cc/public/guides/CodeSubmissionPolicy) for more details.
The authors should provide instructions on data access and preparation, including how to access the raw data, preprocessed data, intermediate data, and generated data, etc.
The authors should provide scripts to reproduce all experimental results for the new proposed method and baselines. If only a subset of experiments are reproducible, they should state which ones are omitted from the script and why.
At submission time, to preserve anonymity, the authors should release anonymized versions (if applicable).
Providing as much information as possible in supplemental material (appended to the paper) is recommended, but including URLs to data and code is permitted.
Experimental setting/details
Question: Does the paper specify all the training and test details (e.g., data splits, hyperparameters, how they were chosen, type of optimizer) necessary to understand the results?
Answer: [Yes]
Justification: The paper specifies dataset splits, evaluation protocols, and metric definitions for all REFORM-3D modules in the main text, and provides experimental details in the supplementary material, including dataset construction, preprocessing, feature extraction, training configurations, hyperparameters, and random seeds. These details specify the training and evaluation settings needed to interpret the reported results.
Guidelines:
The answer [N/A] means that the paper does not include experiments.
The experimental setting should be presented in the core of the paper to a level of detail that is necessary to appreciate the results and make sense of them.
The full details can be provided either with the code, in appendix, or as supplemental material.
Experiment statistical significance
Question: Does the paper report error bars suitably and correctly defined or other appropriate information about the statistical significance of the experiments?
Answer: [Yes]
Justification: Section C.5 defines sample SD across evaluation seeds 42/123/456 and paired bootstrap confidence intervals for controlled ISO/REL/SA comparisons. The intervals use metric-specific resampling and Bonferroni adjustment across the three predefined contrasts. They quantify fixed-checkpoint evaluation variability, not independent pretraining-run variability.
Guidelines:
The answer [N/A] means that the paper does not include experiments.
The authors should answer [Yes] if the results are accompanied by error bars, confidence intervals, or statistical significance tests, at least for the experiments that support the main claims of the paper.
The factors of variability that the error bars are capturing should be clearly stated (for example, train/test split, initialization, random drawing of some parameter, or overall run with given experimental conditions).
The method for calculating the error bars should be explained (closed form formula, call to a library function, bootstrap, etc.)
The assumptions made should be given (e.g., Normally distributed errors).
It should be clear whether the error bar is the standard deviation or the standard error of the mean.
It is OK to report 1-sigma error bars, but one should state it. The authors should preferably report a 2-sigma error bar than state that they have a 96% CI, if the hypothesis of Normality of errors is not verified.
For asymmetric distributions, the authors should be careful not to show in tables or figures symmetric error bars that would yield results that are out of range (e.g., negative error rates).
If error bars are reported in tables or plots, the authors should explain in the text how they were calculated and reference the corresponding figures or tables in the text.
Experiments compute resources
Question: For each experiment, does the paper provide sufficient information on the computer resources (type of compute workers, memory, time of execution) needed to reproduce the experiments?
Answer: [Yes]
Justification: Section E.4 reports GPU types and counts, pretraining duration, and approximate evaluation runtimes.
Guidelines:
The answer [N/A] means that the paper does not include experiments.
The paper should indicate the type of compute workers CPU or GPU, internal cluster, or cloud provider, including relevant memory and storage.
The paper should provide the amount of compute required for each of the individual experimental runs as well as estimate the total compute.
The paper should disclose whether the full research project required more compute than the experiments reported in the paper (e.g., preliminary or failed experiments that didn’t make it into the paper).
Code of ethics
Question: Does the research conducted in the paper conform, in every respect, with the NeurIPS Code of Ethics https://neurips.cc/public/EthicsGuidelines?
Answer: [Yes]
Justification: The research evaluates representations using existing medical imaging datasets. Section E.3 describes provider-controlled access and redistribution constraints, while the Societal Impact statement addresses benchmark overreliance, patient-group differences, and privacy requirements for downstream use.
Guidelines:
The answer [N/A] means that the authors have not reviewed the NeurIPS Code of Ethics.
If the authors answer [No], they should explain the special circumstances that require a deviation from the Code of Ethics.
The authors should make sure to preserve anonymity (e.g., if there is a special consideration due to laws or regulations in their jurisdiction).
Broader impacts
Question: Does the paper discuss both potential positive societal impacts and negative societal impacts of the work performed?
Answer: [Yes]
Justification: The paper discusses the broader implications of representation-level evaluation in medical imaging. Positive impacts include improved understanding and evaluation of 3D medical foundation models, which can contribute to more reliable and robust medical AI systems. Potential negative impacts include over-reliance on benchmark results, bias inherited from underlying datasets, and the risk of misinterpreting evaluation outcomes in downstream clinical applications. The work emphasizes that evaluation results should be interpreted within the defined evaluation surfaces to mitigate misuse.
Guidelines:
The answer [N/A] means that there is no societal impact of the work performed.
If the authors answer [N/A] or [No], they should explain why their work has no societal impact or why the paper does not address societal impact.
Examples of negative societal impacts include potential malicious or unintended uses (e.g., disinformation, generating fake profiles, surveillance), fairness considerations (e.g., deployment of technologies that could make decisions that unfairly impact specific groups), privacy considerations, and security considerations.
The conference expects that many papers will be foundational research and not tied to particular applications, let alone deployments. However, if there is a direct path to any negative applications, the authors should point it out. For example, it is legitimate to point out that an improvement in the quality of generative models could be used to generate Deepfakes for disinformation. On the other hand, it is not needed to point out that a generic algorithm for optimizing neural networks could enable people to train models that generate Deepfakes faster.
The authors should consider possible harms that could arise when the technology is being used as intended and functioning correctly, harms that could arise when the technology is being used as intended but gives incorrect results, and harms following from (intentional or unintentional) misuse of the technology.
If there are negative societal impacts, the authors could also discuss possible mitigation strategies (e.g., gated release of models, providing defenses in addition to attacks, mechanisms for monitoring misuse, mechanisms to monitor how a system learns from feedback over time, improving the efficiency and accessibility of ML).
Safeguards
Question: Does the paper describe safeguards that have been put in place for responsible release of data or models that have a high risk for misuse (e.g., pre-trained language models, image generators, or scraped datasets)?
Answer: [N/A]
Justification: The released assets are a representation-evaluation framework and medical-image encoders, not assets identified as high-risk for misuse. Provider-controlled patient data remain subject to source restrictions, and benchmark results are not presented as clinical validation.
Guidelines:
The answer [N/A] means that the paper poses no such risks.
Released models that have a high risk for misuse or dual-use should be released with necessary safeguards to allow for controlled use of the model, for example by requiring that users adhere to usage guidelines or restrictions to access the model or implementing safety filters.
Datasets that have been scraped from the Internet could pose safety risks. The authors should describe how they avoided releasing unsafe images.
We recognize that providing effective safeguards is challenging, and many papers do not require this, but we encourage authors to take this into account and make a best faith effort.
Licenses for existing assets
Question: Are the creators or original owners of assets (e.g., code, data, models), used in the paper, properly credited and are the license and terms of use explicitly mentioned and properly respected?
Answer: [No]
Justification: The paper uses publicly available medical imaging datasets and properly cites their original sources. The work relies on standard benchmark datasets that are commonly used in the field and assumes adherence to their respective usage policies.
Guidelines:
The answer [N/A] means that the paper does not use existing assets.
The authors should cite the original paper that produced the code package or dataset.
The authors should state which version of the asset is used and, if possible, include a URL.
The name of the license (e.g., CC-BY 4.0) should be included for each asset.
For scraped data from a particular source (e.g., website), the copyright and terms of service of that source should be provided.
If assets are released, the license, copyright information, and terms of use in the package should be provided. For popular datasets, paperswithcode.com/datasets has curated licenses for some datasets. Their licensing guide can help determine the license of a dataset.
For existing datasets that are re-packaged, both the original license and the license of the derived asset (if it has changed) should be provided.
If this information is not available online, the authors are encouraged to reach out to the asset’s creators.
New assets
Question: Are new assets introduced in the paper well documented and is the documentation provided alongside the assets?
Answer: [Yes]
Justification: The paper documents REFORM-3D and Med3DINO through their evaluation protocols, pretraining settings, and limitations. Section E and Table 23 describe the REFORM-3D package, installation resources, configurations, checkpoint records, and usage documentation.
Guidelines:
The answer [N/A] means that the paper does not release new assets.
Researchers should communicate the details of the dataset/code/model as part of their submissions via structured templates. This includes details about training, license, limitations, etc.
The paper should discuss whether and how consent was obtained from people whose asset is used.
At submission time, remember to anonymize your assets (if applicable). You can either create an anonymized URL or include an anonymized zip file.
Crowdsourcing and research with human subjects
Question: For crowdsourcing experiments and research with human subjects, does the paper include the full text of instructions given to participants and screenshots, if applicable, as well as details about compensation (if any)?
Answer: [N/A]
Justification: This study uses existing medical imaging datasets and involves no new participant recruitment, crowdsourcing, or participant-facing data collection.
Guidelines:
The answer [N/A] means that the paper does not involve crowdsourcing nor research with human subjects.
Including this information in the supplemental material is fine, but if the main contribution of the paper involves human subjects, then as much detail as possible should be included in the main paper.
According to the NeurIPS Code of Ethics, workers involved in data collection, curation, or other labor should be paid at least the minimum wage in the country of the data collector.
Institutional review board (IRB) approvals or equivalent for research with human subjects
Question: Does the paper describe potential risks incurred by study participants, whether such risks were disclosed to the subjects, and whether Institutional Review Board (IRB) approvals (or an equivalent approval/review based on the requirements of your country or institution) were obtained?
Answer: [N/A] Justification: The paper does not involve research with human subjects or crowdsourcing. All experiments are conducted on existing publicly available medical imaging datasets, and no new human data collection or participant interaction is performed.
Guidelines:
The answer [N/A] means that the paper does not involve crowdsourcing nor research with human subjects.
Depending on the country in which research is conducted, IRB approval (or equivalent) may be required for any human subjects research. If you obtained IRB approval, you should clearly state this in the paper.
We recognize that the procedures for this may vary significantly between institutions and locations, and we expect authors to adhere to the NeurIPS Code of Ethics and the guidelines for their institution.
For initial submissions, do not include any information that would break anonymity (if applicable), such as the institution conducting the review.
Declaration of LLM usage
Question: Does the paper describe the usage of LLMs if it is an important, original, or non-standard component of the core methods in this research? Note that if the LLM is used only for writing, editing, or formatting purposes and does not impact the core methodology, scientific rigor, or originality of the research, declaration is not required.
Answer: [N/A]
Justification: The core methods and experiments in this paper do not involve LLMs as part of the methodology. Any potential use of LLMs was limited to writing or editing assistance and does not affect the scientific contributions.
Guidelines:
The answer [N/A] means that the core method development in this research does not involve LLMs as any important, original, or non-standard components.
Please refer to our LLM policy in the NeurIPS handbook for what should or should not be described.
References
- [1]Tony Xu, Sepehr Hosseini, Chris Anderson, Anthony Rinaldi, Rahul G Krishnan, Anne L Martel, et al. A generalizable 3D framework and model for self-supervised learning in medical imaging. npj Digital Medicine, 8(1):639, 2025.DOI
- [2]Lev Ayzenberg, Raja Giryes, and Hayit Greenspan. DINOV2 based self supervised learning for few shot medical image segmentation. In 2024 IEEE International Symposium on Biomedical Imaging (ISBI), pages 1–5. IEEE, 2024.arxiv.org/abs/2403.03273
- [3]Yuheng Li, Yizhou Wu, Yuxiang Lai, Mingzhe Hu, and Xiaofeng Yang. MedDINOv3: How to adapt vision foundation models for medical image segmentation? arXiv preprint arXiv:2509.02379, 2025.arxiv.org/abs/2509.02379
- [4]Fernando Pérez-García, Harshita Sharma, Sam Bond-Taylor, Kenza Bouzid, Valentina Salvatielli, Maximilian Ilse, et al. Exploring scalable medical image encoders beyond text supervision. Nature Machine Intelligence, 7(1):119–130, 2025.
- [5]Samuel Joutard, Maximilian Pietsch, and Raphael Prevost. HyperSpace: Hypernetworks for spacing-adaptive image segmentation. In International conference on medical image computing and computer-assisted intervention, pages 339–349. Springer, 2024.arxiv.org/abs/2407.03681
- [6]Xian Lin, Xiayu Guo, Zengqiang Yan, and Li Yu. Selective intra- and inter-slice interaction for efficient anisotropic medical image segmentation. Pattern Recognition, 174:112895, 2026.DOI
- [7]Simon Kornblith, Mohammad Norouzi, Honglak Lee, and Geoffrey Hinton. Similarity of neural network representations revisited. In International conference on machine learning, pages 3519–3529. PMLR, 2019.arxiv.org/abs/1905.00414
- [8]Linshan Wu, Jiaxin Zhuang, and Hao Chen. Large-scale 3D medical image pre-training with geometric context priors. IEEE Transactions on Pattern Analysis and Machine Intelligence, 48(3):3801–3818, 2026.DOI
- [9]Ting Chen, Simon Kornblith, Mohammad Norouzi, and Geoffrey Hinton. A simple framework for contrastive learning of visual representations. In International conference on machine learning, pages 1597–1607. PMLR, 2020.arxiv.org/abs/2002.05709
- [10]Kaiming He, Haoqi Fan, Yuxin Wu, Saining Xie, and Ross Girshick. Momentum contrast for unsupervised visual representation learning. In Proceedings of the IEEE/CVF conference on computer vision and pattern recognition, pages 9729–9738, 2020.arxiv.org/abs/1911.05722
- [11]Mathilde Caron, Hugo Touvron, Ishan Misra, Hervé Jégou, Julien Mairal, Piotr Bojanowski, et al. Emerging properties in self-supervised vision transformers. In Proceedings of the IEEE/CVF international conference on computer vision, pages 9650–9660, 2021.arxiv.org/abs/2104.14294
- [12]Maxime Oquab, Timothée Darcet, Théo Moutakanni, Huy V. Vo, Marc Szafraniec, Vasil Khalidov, et al. DINOv2: Learning robust visual features without supervision. Transactions on Machine Learning Research, 2024.
- [13]Oriane Siméoni, Huy V. Vo, Maximilian Seitzer, Federico Baldassarre, Maxime Oquab, Cijo Jose, et al. DINOv3, 2025. arXiv:2508.10104.arxiv.org/abs/2508.10104
- [14]Luca Zedda, Andrea Loddo, and Cecilia Di Ruberto. Radio DINO: A foundation model for advanced radiomics and AI-driven medical imaging analysis. Computers in Biology and Medicine, 195:110583, 2025.DOI
- [15]Divyanshu Tak, Biniam A Garomsa, Anna Zapaishchykova, Tafadzwa L Chaunzwa, Juan Carlos Climent Pardo, Zezhong Ye, et al. A generalizable foundation model for analysis of human brain MRI. Nature Neuroscience, 29(4):945–956, 2026.DOI
- [16]Tassilo Wald, Constantin Ulrich, Jonathan Suprijadi, Sebastian Ziegler, Michal Nohel, Robin Peretzke, et al. An OpenMind for 3D medical vision self-supervised learning. In Proceedings of the IEEE/CVF International Conference on Computer Vision (ICCV), pages 23839–23879, October 2025.arxiv.org/abs/2412.17041
- [17]Haoyu Wang, Sizheng Guo, Jin Ye, Zhongying Deng, Junlong Cheng, Tianbin Li, et al. SAM-Med3D: A vision foundation model for general-purpose segmentation on volumetric medical images. IEEE Transactions on Neural Networks and Learning Systems, 36(10):17599–17612, 2025.DOI
- [18]Fenghe Tang, Qingsong Yao, Wenxin Ma, Chenxu Wu, Zihang Jiang, and S. Kevin Zhou. Hi-End-MAE: Hierarchical encoder-driven masked autoencoders are stronger vision learners for medical image segmentation. Medical Image Analysis, 107:103770, 2026.arxiv.org/abs/2502.08347
- [19]Fenghe Tang, Bingkun Nian, Yingtai Li, Zihang Jiang, Jie Yang, Wei Liu, et al. MambaMIM: Pre-training mamba with state space token interpolation and its application to medical image segmentation. Medical Image Analysis, 103:103606, 2025.DOI
- [20]Jiaxin Zhuang, Linshan Wu, Qiong Wang, Peng Fei, Varut Vardhanabhuti, Lin Luo, et al. MiM: Mask in mask self-supervised pre-training for 3D medical image analysis. IEEE Transactions on Medical Imaging, 44(9):3727–3740, 2025.DOI
- [21]Jiaxin Zhuang, Luyang Luo, Qiong Wang, Mingxiang Wu, Lin Luo, and Hao Chen. Advancing volumetric medical image segmentation via global-local masked autoencoders. IEEE Transactions on Medical Imaging, 44(11):4226–4238, 2025.DOI
- [22]Yang Zhou, Tan Li Hui Faith, Yanyu Xu, Sicong Leng, Xinxing Xu, Yong Liu, et al. BenchX: A unified benchmark framework for medical vision-language pretraining on chest X-Rays. In Advances in Neural Information Processing Systems, volume 37, pages 6625–6647, 2024.arxiv.org/abs/2410.21969
- [23]Pengcheng Chen, Jin Ye, Guoan Wang, Yanjun Li, Zhongying Deng, Wei Li, et al. GMAI-MMBench: A comprehensive multimodal evaluation benchmark towards general medical AI. Advances in Neural Information Processing Systems, 37:94327–94427, 2024.arxiv.org/abs/2408.03361
- [24]Ruianan Jin, Zikang Xu, Yuan Zhong, Qingsong Yao, Qi Dou, S. Kevin Zhou, et al. FairMedFM: Fairness benchmarking for medical imaging foundation models. In A. Globerson, L. Mackey, D. Belgrave, A. Fan, U. Paquet, J. Tomczak, and C. Zhang, editors, Advances in Neural Information Processing Systems, volume 37, pages 111318–111357. Curran Associates, Inc., 2024.arxiv.org/abs/2407.00983
- [25]Xiaotang Gai, Jiaxiang Liu, Yichen Li, Zijie Meng, Jian Wu, and Zuozhu Liu. 3D-RAD: A comprehensive 3D radiology Med-VQA dataset with multi-temporal analysis and diverse diagnostic tasks. In The Thirty-ninth Annual Conference on Neural Information Processing Systems Datasets and Benchmarks Track, 2025.arxiv.org/abs/2506.11147
- [26]Miriam Cobo, David Corral Fontecha, Wilson Silva, and Lara Lloret Iglesias. Physical foundations for trustworthy medical imaging: A survey for artificial intelligence researchers. Artificial Intelligence in Medicine, 169:103251, 2025.DOI
- [27]Alex Ling Yu Hung, Haoxin Zheng, Kai Zhao, Xiaoxi Du, Kaifeng Pang, Qi Miao, et al. CSAM: A 2.5D cross-slice attention module for anisotropic volumetric medical image segmentation. In Proceedings of the IEEE/CVF Winter Conference on Applications of Computer Vision, pages 5923–5932, 2024.DOI
- [28]Wenxuan Li, Alan Yuille, and Zongwei Zhou. How well do supervised 3D models transfer to medical imaging tasks? In International Conference on Learning Representations, volume 2024, pages 16389–16404, 2024.arxiv.org/abs/2501.11253
- [29]An Zeng, Chunbiao Wu, Guisen Lin, Wen Xie, Jin Hong, Meiping Huang, et al. ImageCAS: A large-scale dataset and benchmark for coronary artery segmentation based on computed tomography angiography images. Computerized Medical Imaging and Graphics, 109:102287, 2023.DOI
- [30]Chin-Fu Liu, Richard Leigh, Brenda Johnson, Victor Urrutia, Johnny Hsu, Xin Xu, et al. A large public dataset of annotated clinical MRIs and metadata of patients with acute stroke. Scientific Data, 10(1):548, 2023.
- [31]Jakob Wasserthal, Hanns-Christian Breit, Manfred T Meyer, Maurice Pradella, Daniel Hinck, Alexander W Sauter, et al. TotalSegmentator: Robust segmentation of 104 anatomic structures in CT images. Radiology: Artificial Intelligence, 5(5):e230024, 2023.DOI
- [32]Numan Saeed, Salma Hassan, Shahad Hardan, Lishan Cai, Xinglong Liang, Moona Mazher, et al. HEad and neCK TumOR (HECKTOR) 2025: Benchmark of segmentation, diagnosis, and prognosis in multimodal PET/CT, 2026. arXiv:2606.20143.arxiv.org/abs/2606.20143
- [33]Nicholas Heller, Fabian Isensee, Dasha Trofimova, Resha Tejpaul, Zhongchen Zhao, Huai Chen, et al. The KiTS21 challenge: Automatic segmentation of kidneys, renal tumors, and renal cysts in corticomedullary-phase CT, 2023. arXiv:2307.01984.arxiv.org/abs/2307.01984
- [34]Tugba Akinci D’Antonoli, Lucas K Berger, Ashraya K Indrakanti, Nathan Vishwanathan, Jakob Weiss, Matthias Jung, et al. TotalSegmentator MRI: Robust sequence-independent segmentation of multiple anatomic structures in MRI. Radiology, 314(2):e241613, 2025.
- [35]A Emre Kavur, N Sinem Gezer, Mustafa Baris, Sinem Aslan, Pierre-Henri Conze, Vladimir Groza, et al. CHAOS challenge-combined (CT-MR) healthy abdominal organ segmentation. Medical image analysis, 69:101950, 2021.DOI
- [36]Yuanfeng Ji, Haotian Bai, Chongjian Ge, Jie Yang, Ye Zhu, Ruimao Zhang, et al. AMOS: A large-scale abdominal multi-organ benchmark for versatile medical image segmentation. In Proceedings of the 36th International Conference on Neural Information Processing Systems. Curran Associates Inc., 2022.arxiv.org/abs/2206.08023
- [37]Xiahai Zhuang, Lei Li, Christian Payer, Darko Štern, Martin Urschler, Mattias P Heinrich, et al. Evaluation of algorithms for multi-modality whole heart segmentation: An open-access grand challenge. Medical image analysis, 58:101537, 2019.arxiv.org/abs/1902.07880
- [38]Bennett Landman, Zhoubing Xu, Juan Iglesias, Martin Styner, Thomas Langerak, and Arno Klein. Miccai multi-atlas labeling beyond the cranial vault–workshop and challenge. In Proc. MICCAI multi-atlas labeling beyond cranial vault—workshop and challenge, volume 5, page 12. Munich, Germany, 2015.
- [39]Ujjwal Baid, Satyam Ghodasara, Suyash Mohan, Michel Bilello, Evan Calabrese, Errol Colak, et al. The RSNA-ASNR-MICCAI BraTS 2021 benchmark on brain tumor segmentation and radiogenomic classification, 2021. arXiv:2107.02314.arxiv.org/abs/2107.02314
- [40]Moritz R Hernandez Petzsche, Ezequiel De La Rosa, Uta Hanning, Roland Wiest, Waldo Valenzuela, Mauricio Reyes, et al. ISLES 2022: A multi-center magnetic resonance imaging stroke lesion segmentation dataset. Scientific data, 9(1):762, 2022.
- [41]Xiangde Luo, Wenjun Liao, Jianghong Xiao, Jieneng Chen, Tao Song, Xiaofan Zhang, et al. WORD: A large scale dataset, benchmark and clinical applicable study for abdominal organ segmentation from CT image. Medical Image Analysis, 82:102642, 2022.DOI
- [42]Zhaohan Xiong, Qing Xia, Zhiqiang Hu, Ning Huang, Cheng Bian, Yefeng Zheng, et al. A global benchmark of algorithms for segmenting the left atrium from late gadolinium-enhanced cardiac magnetic resonance imaging. Medical Image Analysis, 67:101832, 2021.DOI
- [43]Gongning Luo, Mingwang Xu, Hongyu Chen, Xinjie Liang, Xing Tao, Dong Ni, et al. Tumor detection, segmentation and classification challenge on automated 3D breast ultrasound: The TDSC-ABUS Challenge. arXiv preprint arXiv:2501.15588, 2025.arxiv.org/abs/2501.15588
- [44]Jun Ma, Yao Zhang, Song Gu, Cheng Zhu, Cheng Ge, Yichi Zhang, et al. AbdomenCT-1K: Is abdominal organ segmentation a solved problem? IEEE Transactions on Pattern Analysis and Machine Intelligence, 44(10):6695–6714, 2022.DOI
- [45]Minghui Zhang, Yangqian Wu, Hanxiao Zhang, Yulei Qin, Hao Zheng, Wen Tang, et al. Multi-site, multi-domain airway tree modeling. Medical Image Analysis, 90:102957, 2023.DOI
- [46]Bjoern H. Menze, Andras Jakab, Stefan Bauer, Jayshree Kalpathy-Cramer, Keyvan Farahani, Justin Kirby, et al. The multimodal brain tumor image segmentation benchmark (brats). IEEE Transactions on Medical Imaging, 34(10):1993–2024, 2015.DOI
- [47]Spyridon Bakas, Mauricio Reyes, Andras Jakab, Stefan Bauer, Markus Rempfler, Alessandro Crimi, et al. Identifying the best machine learning algorithms for brain tumor segmentation, progression assessment, and overall survival prediction in the brats challenge, 2019. arXiv:1811.02629.arxiv.org/abs/1811.02629
- [48]Spyridon Bakas, Hamed Akbari, Aristeidis Sotiras, Michel Bilello, Martin Rozycki, Justin S. Kirby, et al. Advancing the cancer genome atlas glioma MRI collections with expert segmentation labels and radiomic features. Scientific Data, 4:170117, 2017.DOI
- [49]Ilya Nelkenbaum, Galia Tsarfaty, Nahum Kiryati, Eli Konen, and Arnaldo Mayer. Automatic segmentation of white matter tracts using multiple brain MRI sequences. In 2020 IEEE 17th International Symposium on Biomedical Imaging (ISBI), pages 368–371, 2020.
- [50]COSMOS 2022: Carotid vessel wall segmentation and atherosclerosis diagnosis challenge. https://vessel-wall-segmentation-2022.grand-challenge.org/, 2022.
- [51]Jun Ma, Yixin Wang, Xingle An, Cheng Ge, Ziqi Yu, Jianan Chen, et al. Toward data-efficient learning: A benchmark for COVID-19 CT lung and infection segmentation. Medical Physics, 48(3):1197–1210, 2021.DOI
- [52]Jonathan Shapey, Aaron Kujawa, Reuben Dorent, Guotai Wang, Alexis Dimitriadis, Diana Grishuk, et al. Segmentation of vestibular schwannoma from mri, an open annotated dataset and baseline algorithm. Scientific Data, 8(1):286, 2021.DOI
- [53]Reuben Dorent, Aaron Kujawa, Marina Ivory, Spyridon Bakas, Nicola Rieke, Samuel Joutard, et al. CrossMoDA 2021 challenge: Benchmark of cross-modality domain adaptation techniques for vestibular schwannoma and cochlea segmentation. Medical Image Analysis, 83:102628, 2023.DOI
- [54]Blaine Rister, Darvin Yi, Kaushik Shivakumar, Tomomi Nobashi, and Daniel L. Rubin. CT-ORG, a new dataset for multiple organ segmentation in computed tomography. Scientific Data, 7(1):381, 2020.DOI
- [55]Pengbo Liu et al. Deep learning to segment pelvic bones: large-scale CT datasets and baseline models. International Journal of Computer Assisted Radiology and Surgery, 16:749–756, 2021.DOI
- [56]Jun Ma, Yao Zhang, Song Gu, Xingle An, Zhihe Wang, Cheng Ge, et al. Fast and low-gpu-memory abdomen CT organ segmentation: The Flare Challenge. Medical Image Analysis, 82:102616, 2022.DOI
- [57]Jun Ma, Yao Zhang, Song Gu, Cheng Ge, Shihao Ma, Adamo Young, et al. Unleashing the strengths of unlabelled data in deep learning-assisted pan-cancer abdominal organ quantification: the FLARE22 challenge. The Lancet Digital Health, 6(11):e815–e826, 2024.DOI
- [58]Evamaria Olga Riedel, Ezequiel de la Rosa, The Anh Baran, Moritz Hernandez Petzsche, Hakim Baazaoui, Kaiyuan Yang, et al. ISLES’24 – a real-world longitudinal multimodal stroke dataset, 2025. arXiv:2408.11142.arxiv.org/abs/2408.11142
- [59]Yuting He, Guanyu Yang, Jian Yang, Rongjun Ge, Youyong Kong, Xiaomei Zhu, et al. Meta grayscale adaptive network for 3D integrated renal structures segmentation. Medical Image Analysis, 71:102055, 2021.DOI
- [60]Lei Li, Veronika A. Zimmer, Julia A. Schnabel, and Xiahai Zhuang. Atrialgeneral: Domain generalization for left atrial segmentation of multi-center lge mris. In Marleen de Bruijne, Philippe C. Cattin, Stéphane Cotin, Nicolas Padoy, Stefanie Speidel, Yefeng Zheng, and Caroline Essert, editors, Medical Image Computing and Computer Assisted Intervention – MICCAI 2021, pages 557–566, Cham, 2021. Springer International Publishing.arxiv.org/abs/2106.08727
- [61]Patrick Bilic, Patrick Christ, Hongwei Bran Li, Eugene Vorontsov, Avi Ben-Cohen, Georgios Kaissis, et al. The liver tumor segmentation benchmark (LiTS). Medical Image Analysis, 84:102680, 2023.DOI
- [62]Arnaud Arindra Adiyoso Setio, Alberto Traverso, Thomas de Bel, Moira S.N. Berens, Cas van den Bogaard, Piergiorgio Cerello, et al. Validation, comparison, and combination of algorithms for automatic detection of pulmonary nodules in computed tomography images: The LUNA16 challenge. Medical Image Analysis, 42:1–13, 2017.DOI
- [63]Michela Antonelli, Annika Reinke, Spyridon Bakas, Keyvan Farahani, Annette Kopp-Schneider, Bennett A Landman, et al. The medical segmentation decathlon. Nature communications, 13(1):4128, 2022.
- [64]Anindo Saha, Joeran S Bosma, Jasper J Twilt, Bram van Ginneken, Anders Bjartell, Anwar R Padhani, et al. Artificial intelligence and radiologists in prostate cancer detection on MRI (pi-cai): an international, paired, non-inferiority, confirmatory study. The Lancet Oncology, 25(7):879–887, 2024.DOI
- [65]Jason Dowling, Jurgen Fripp, Peter Greer, Sébastien Ourselin, and Olivier Salvado. Automatic atlas-based segmentation of the prostate: A MICCAI 2009 prostate segmentation challenge entry. In MICCAI 2009 Prostate Segmentation Challenge Workshop, London, UK, 2009.
- [66]Geert Litjens, Robert Toth, Wendy van de Ven, Caroline Hoeks, Sjoerd Kerkstra, Bram van Ginneken, et al. Evaluation of prostate segmentation algorithms for MRI: The PROMISE12 challenge. Medical Image Analysis, 18(2):359–373, 2014.DOI
- [67]Jiancheng Yang, Rui Shi, Liang Jin, Xiaoyang Huang, Kaiming Kuang, Donglai Wei, et al. Deep rib fracture instance segmentation and classification from CT on the RibFrac challenge. IEEE Transactions on Medical Imaging, 44(8):3410–3427, 2025.DOI
- [68]Tobias Heimann, Bram Van Ginneken, Martin A Styner, Yulia Arzhaeva, Volker Aurich, Christian Bauer, et al. Comparison and evaluation of methods for liver segmentation from CT datasets. IEEE transactions on medical imaging, 28(8):1251–1265, 2009.DOI
- [69]Rashed Karim, Lauren-Emma Blake, Jiro Inoue, Qian Tao, Shuman Jia, R. James Housden, et al. Algorithms for left atrial wall segmentation and thickness – evaluation on an open-source CT and MRI image database. Medical Image Analysis, 50:36–53, 2018.DOI
- [70]StructSeg2019: Automatic structure segmentation for radiotherapy planning challenge 2019. https://structseg2019.grand-challenge.org/Home/, 2019.
- [71]Anjany Sekuboyina, Malek E Hussein, Amirhossein Bayat, Maximilian Löffler, Hans Liebl, Hongwei Li, et al. VerSe: A vertebrae labelling and segmentation benchmark for multi-detector ct images. Medical Image Analysis, 73:102166, 2021.DOI
- [72]Hans Liebl, David Schinz, Anjany Sekuboyina, Luca Malagutti, Maximilian T Löffler, Amirhossein Bayat, et al. A computed tomography vertebral segmentation dataset with anatomical variations and multi-vendor scanner data. Scientific data, 8(1):284, 2021.arxiv.org/abs/2103.06360
- [73]Jeffrey D. Rudie, Hui-Ming Lin, Robyn L. Ball, et al. The RSNA abdominal traumatic injury CT (RATIC) dataset. Radiology: Artificial Intelligence, 6(6):e240101, 2024.arxiv.org/abs/2405.19595
- [74]Rachel Lea Draelos, David Dov, Maciej A. Mazurowski, Joseph Y. Lo, Ricardo Henao, Geoffrey D. Rubin, et al. Machine-learning-based multiple abnormality prediction with large-scale chest computed tomography volumes. Medical Image Analysis, 67:101857, 2021.DOI
- [75]M.J.J. de Grauw, E.Th. Scholten, E.J. Smit, M.J.C.M. Rutten, M. Prokop, B. van Ginneken, et al. The ULS23 challenge: A baseline model and benchmark dataset for 3D universal lesion segmentation in computed tomography. Medical Image Analysis, 102:103525, 2025.DOI
- [76]Sergios Gatidis, Tobias Hepp, Marcel Früh, Christian La Fougere, Konstantin Nikolaou, Christina Pfannenberg, et al. A whole-body FDG-PET/CT dataset with manually annotated tumor lesions. Scientific Data, 9(1):601, 2022.DOI
- [77]Katharina Jeblick, Balthasar Schachtner, Andreas Mittermeier, Jakob Dexl, Philipp Wesp, Thomas Küstner, et al. A whole-body PSMA-PET/CT dataset with manually annotated tumor lesions. Scientific Data, 13(1):1023, 2026.DOI
- [78]Jacob A. Macdonald, Zhe Zhu, Brandon Konkel, Maciej A. Mazurowski, Walter F. Wiggins, and Mustafa R. Bashir. Duke liver dataset: A publicly available liver MRI dataset with liver segmentation masks and series labels. Radiology: Artificial Intelligence, 5(5):e220275, 2023.DOI
- [79]Shanshan Song, Hailong Qiu, Meiping Huang, Jian Zhuang, Qing Lu, Yiyu Shi, et al. Domain knowledge based comprehensive segmentation of Type-A aortic dissection with clinically-oriented evaluation. Medical Image Analysis, 102:103512, 2025.DOI
- [80]Zeyang Yao, Wen Xie, Jiawei Zhang, Yuhao Dong, Hailong Qiu, Haiyun Yuan, et al. ImageT-BAD: A 3D computed tomography angiography image dataset for automatic segmentation of type-b aortic dissection. Frontiers in Physiology, 12:732711, 2021.
- [81]Yang Deng, Ce Wang, Yuan Hui, Qian Li, Jun Li, Shiwei Luo, et al. CTSpine1K: A large-scale dataset for spinal vertebrae segmentation in computed tomography, 2024. arXiv:2105.14711.arxiv.org/abs/2105.14711
- [82]Jure Zbontar, Florian Knoll, Anuroop Sriram, Tullie Murrell, Zhengnan Huang, Matthew J. Muckley, et al. fastMRI: An open dataset and benchmarks for accelerated MRI, 2018. arXiv:1811.08839.arxiv.org/abs/1811.08839
- [83]Federico Bolelli, Luca Lumetti, Shankeeth Vinayavahalingam, Mattia Di Bartolomeo, Arrigo Pellacani, Kevin Marchesini, et al. Segmenting the inferior alveolar canal in CBCTs volumes: The ToothFairy challenge. IEEE Transactions on Medical Imaging, 44(4):1890–1906, 2025.DOI
- [84]Federico Bolelli, Kevin Marchesini, Niels van Nիստelrooij, Luca Lumetti, Vittorio Pipoli, Elisa Ficarra, et al. Segmenting maxillofacial structures in CBCT volumes. In Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR), pages 5238–5248, June 2025.DOI
- [85]Yaqi Wang, Fan Ye, Yifei Chen, Chengkai Wang, Chengyu Wu, Feng Xu, et al. A multi-modal dental dataset for semi-supervised deep learning image segmentation. Scientific Data, 12(1):117, 2025.DOI




