Bayesian Image Reconstruction and Uncertainty Quantification for Three-Photon Positronium Ratio Imaging: Toward Radiotheranostic Applications

Abstract

Three-photon annihilation imaging can estimate positronium decay ratios with pure positron emitters, including the imaging agents of radiotheranostic pairs, but quantitative reconstruction is limited by heterogeneous localization errors, selection-dependent sensitivity, and background coincidences. We develop a Bayesian reconstruction combining a three-dimensional event-response model with a Poisson likelihood and latent signal-background allocations. Photon-energy and interaction-position uncertainties enter the event covariance; a simulation-calibrated scale mixture accommodates heavy-tailed errors. Posterior sampling gives credible intervals for the three-to-two-photon enhancement ratio. We compare kernel deposition, voxel MLEM, and matched regional maximum likelihood. At 3000 selected events in full-absorption simulation, the regional Bayesian estimator had ratio RMSE 0.067, versus 0.075 for kernel-deposition region-of-interest analysis. In a transport-based four-rod simulation without background, biases averaged at most 3.2% over six independent simulations, whereas background and detector mismatch degraded it. In a measured uniform phantom, the heavy-tailed regional model gave 1.02, 0.74, 1.02 for the 2, 3, 4 mm rods (5 mm reference; nominal 1). Matched regional maximum likelihood agreed with the Bayesian estimates in every simulated setting (bias differences within 0.15 points) and on the measured data (within 0.008), so gains derive from the regional likelihood. Under Poisson Kullback-Leibler loss, Gamma posterior means dominate maximum likelihood, appreciably only at small counts; horseshoe-type and smoothing priors changed voxel images but not regional ratios, whereas shrinking ratios across regions reduced error when regions shared a ratio. Posterior intervals quantify the uncertainty that treatment decisions require; calibration and background modeling remain limiting.

Introduction

This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may no longer be accessible. This work did not involve human subjects or animals in its research.

H.-H. Huang, B. Uluutku and A. F. Torres are with the Dr. Yvette Kanouff School of Data, Mathematical, and Statistical Sciences, University of Central Florida, Orlando, FL 32816, USA (e-mail: [email protected]; corresponding author).

M. Fujimoto is with the Department of Bioengineering, The University of Tokyo, Tokyo, Japan.

K. Shimazoe is with the Department of Bioengineering and the Department of Nuclear Engineering and Management, The University of Tokyo, Tokyo, Japan.

POSiTRONIUM imaging seeks information about the tissue microenvironment beyond radiotracer uptake. The term three-gamma imaging includes physically distinct measurements. Tashima and Yamaya [1] review methods that detect two annihilation photons together with a nuclear prompt gamma, including isotope discrimination, direct localization [2, 3], and positronium lifetime imaging (PLI) [4, 5]. In contrast, the present work reconstructs the three photons emitted in a single ortho-positronium annihilation. Their energies sum to approximately 1022 keV, and their directions satisfy momentum conservation. This process supports positronium ratio imaging (PRI) with pure positron emitters such as 18^{18}F [6, 7].

Ratio imaging is relevant to radiotheranostics: unlike lifetime imaging, which needs a prompt-gamma emitter such as 44^{44}Sc [4], it works with the positron-emitting agents that select patients for radioligand therapy, such as 18^{18}F- or 68^{68}Ga-labeled PSMA ligands before 177^{177}Lu-PSMA-617 [8], and 64^{64}Cu paired with 67^{67}Cu (Supplementary Section S18). Treatment planning acts on thresholds, so lesion-level values need calibrated intervals, which we provide and test. Positronium is sensitive to oxygen [9], the three-to-two-photon rate ratio has been proposed as a hypoxia biomarker [10], and β\beta- but hardly α\alpha-particle cell killing depends on oxygenation [11, 12], so a calibrated environment map could help choose between β\beta and α\alpha emitters; this is our motivation, as the link between the three-photon ratio and tissue oxygenation remains to be established.

Our earlier PLI reconstructions model time-of-flight resolution in the likelihood [13, 14, 15, 16]; here the same principle is applied to energy-dependent localization to estimate the three-to-two-photon activity ratio.

Fujimoto et al. localized three-photon events directly from photon energies and interaction positions and estimated regional ratios [6], building on earlier feasibility studies [7, 17]; a companion study examines the point-spread function (PSF) of analytical localization [18]. Other groups localize the vertex from times of flight by trilateration [19], from energies in closed form [20], or from both with a QED prior in an event-by-event Bayesian estimate tested on simulated point sources [21]. This motivates a reconstruction of the ratio itself, with credible intervals, that models event-specific uncertainty, sensitivity, and background instead of treating events as exact sources.

Maximum likelihood estimation (MLE) is a criterion, maximum-likelihood expectation-maximization (MLEM) an algorithm [22], [23], and kernel deposition with ROI integration a different estimator; Bayesian emission reconstruction and latent-origin sampling are established [24]–[26]. Our contribution is their formulation and evaluation for energy-localized three-photon PRI, including position-error propagation, selection-aware response, heavy-tailed event errors, and posterior propagation to a regional enhancement ratio.

We develop voxel and region models and evaluate them using full-absorption simulation, transport-based simulation, and a measured four-rod phantom. Comparison with the published-style ROI pipeline, voxel MLEM, and a matched regional MLE separates the effects of the response model from those of the prior; we also evaluate Poisson-adapted losses and shrinkage priors against matched ML.

Materials and Methods

Vertex Estimator and Event Covariance

For hits AA, BB, CC and energies EE, momentum conservation gives the opening angle ωij\omega_{ij} between photons ii and jj,

cos⁡ωij=Ek2−Ei2−Ej22EiEj.\cos\omega_{ij} = \frac{E_k^2-E_i^2-E_j^2}{2E_iE_j}.

The vertex is the point that subtends these angles, the three-point resection problem, whose closed form is Tienstra’s formula [27]

V=kAA+kBB+kCCkA+kB+kC,kA=(cot⁡a−cot⁡ωBC)−1(1)V = \frac{k_A A+k_B B+k_C C}{k_A+k_B+k_C}, \qquad k_A = \left(\cot a-\cot\omega_{BC}\right)^{-1} \tag*{(1)}

with a,b,ca,b,c the angles of the hit triangle (Supplementary Section S2). It equals the two-arc construction and places VV in the plane of the hits. Linearizing in the twelve inputs gives

Σ=JEDσJET⏟ΣE+∑kJPkΣkhitJPkT⏟ΣH(2)\Sigma= \underbrace{J_E D_\sigma J_E^{\mathsf T}}_{\Sigma_E}+\underbrace{\sum_k J_{P_k}\Sigma_k^{\mathrm{hit}}J_{P_k}^{\mathsf T}}_{\Sigma_H} \tag*{(2)}

where Dσ=diag⁡(σA2,σB2,σC2)D_\sigma=\operatorname{diag}(\sigma_A^2,\sigma_B^2,\sigma_C^2), σk=Ek(FWHM⁡/E)(Ek)/2.355\sigma_k=E_k(\operatorname{FWHM}/E)(E_k)/2.355 and Σkhit\Sigma_k^{\mathrm{hit}} is the covariance of the first-interaction point about the pixel center (transverse variance ≈2.52/12 mm2\approx2.5^2/12\ \mathrm{mm}^2, energy-dependent depth variance from the simulation). ΣE\Sigma_E has rank two and lies in the hit plane; it is the covariance in current use. ΣH\Sigma_H adds the tilt of the decay plane and the axial error. Exactly, JEE=0J_EE=0 (a common gain error cancels) and JPk(Pk−V)=0J_{P_k}(P_k-V)=0 (depth along the photon direction does not propagate) (Supplementary Section S3).

Bayesian Image Reconstruction

Let yiy_i contain the measured photon energies, detector pixels, and reconstructed vertex of selected event ii. For voxel jj, let qjq_j be its expected selected-event yield per unit activity, including acquisition exposure and all analysis cuts. Let h(y∣x)h(y\mid x) be the density of the observation of a selected event from a decay at xx, and hj(y)h_j(y) its qq-weighted average over voxel jj. Thus ∫yhj(y) dy=1\int_y h_j(y)\,dy=1 on the selected observation space. Writing aij=qjhj(yi)a_{ij}=q_jh_j(y_i), the Poisson point-process model is

mi=∑jaijλj+∑cBchc(yi),(3)m_i=\sum_j a_{ij}\lambda_j+\sum_c B_ch_c(y_i), \tag*{(3)}

where Y=(y1,…,yn)Y=(y_1,\ldots,y_n), mim_i is the expected event density at yiy_i summed over all sources, λj≥0\lambda_j\ge0 is voxel activity, BcB_c is the expected count for background class cc, and hch_c is its normalized density.

The working response factors the true-event energy density pEp_E and a spatial kernel, h(yi∣x)∝pE(Ei)ki(x)h(y_i\mid x)\propto p_E(E_i)k_i(x). The Gaussian approximation uses the covariance in (2); the refined kernel is

ki(x)=∑l=1Lπlϕ3(V^i−x;clΣi),k_i(x)=\sum_{l=1}^{L}\pi_l\phi_3\left(\widehat{V}_i-x;c_l\Sigma_i\right),
πl≥0,∑lπl=1,cl>0.(4)\pi_l\ge0,\qquad\sum_l\pi_l=1,\qquad c_l>0. \tag*{(4)}

Here ϕ3(⋅;Σ)\phi_3(\cdot;\Sigma) is the trivariate normal density with covariance Σ\Sigma, Σi=ΣE+ΣH\Sigma_i=\Sigma_{E}+\Sigma_{H} the covariance of event ii, and πl,cl\pi_l,c_l the weights and scale factors; the mixture parameters are fitted to labeled calibration events independently of the evaluated events. This approximate response must be normalized over the selected observations, which is checked by simulation; normalizing over source coordinates alone does not suffice. Sensitivity is estimated after energy smearing and selection (selected fractions 0.423 and 0.402 for a central and an off-axis compartment).

For a known region RrR_r with constant three-photon activity density θr≡θr3\theta_r\equiv\theta_r^3 (three-photon decays per unit volume during the acquisition), define Qr=∫Rrq(x) dxQ_r=\int_{R_r}q(x)\,dx and

Fir=Qr−1∫Rrq(x)h(yi∣x) dx,νr=Qrθr.(5)F_{ir}=Q_r^{-1}\int_{R_r}q(x)h(y_i\mid x)\,dx,\qquad\nu_r=Q_r\theta_r. \tag*{(5)}

The regional intensity is mi=∑rνrFir+∑cBchc(yi)m_i=\sum_r\nu_rF_{ir}+\sum_cB_ch_c(y_i) and its integrated rate is ∑rνr+∑cBc\sum_r\nu_r+\sum_cB_c. Known phantom boundaries provide structural information.

Independent Gamma shape–rate priors yield conjugate updates after introducing an event-origin label ziz_i. For the voxel model,

Pr⁡(zi=j∣yi,λ,B)=aijλjmi,\Pr(z_i=j\mid y_i,\lambda,\mathbf{B})=\frac{a_{ij}\lambda_j}{m_i},
λj∣z∼Gamma⁡(αj+nj,βj+qj).(6)\lambda_j\mid z\sim\operatorname{Gamma}(\alpha_j+n_j,\beta_j+q_j). \tag*{(6)}

Here njn_j is the number of events allocated to voxel jj (nr,ncn_r,n_c likewise for regions and background classes) and αj,βj\alpha_j,\beta_j are the prior shape and rate. Background counts have analogous updates with rate bc+1b_c+1. Regional expected counts use νr∣z∼Gamma⁡(αr+nr,βr+1)\nu_r\mid z\sim\operatorname{Gamma}(\alpha_r+n_r,\beta_r+1). The regional analyses use αr=1/2, βr=0\alpha_r=1/2,\ \beta_r=0, a half-count power prior. It is the Jeffreys form for separately observed Poisson counts, not for overlapping mixture components. Conditional updates and their normalization are given in Supplementary Section S14.

Hierarchy and posterior. With rates u=(ν,B)\mathbf{u}=(\boldsymbol{\nu},\mathbf{B}), responses Hik∈{Fir,hc(yi)}H_{ik}\in\{F_{ir},h_c(y_i)\}, integrated response qkq_k (one for normalized components) and hyperparameters ξ\boldsymbol{\xi},

p(z,u,ξ∣Y)∝∏iHizi∏kuknke−qkukp(u∣ξ)p(ξ).(7)p(\mathbf{z},\mathbf{u},\boldsymbol{\xi}\mid Y)\propto\prod_i H_{iz_i}\prod_k u_k^{n_k}e^{-q_ku_k}p(\mathbf{u}\mid\boldsymbol{\xi})p(\boldsymbol{\xi}). \tag*{(7)}

the measurement model given each event’s origin, the Poisson thinning nk∣uk∼Poisson⁡(qkuk)n_k\mid u_k\sim\operatorname{Poisson}(q_ku_k), the conditional prior and the hyperprior. Summing over zz returns (4); the meaning of each factor and the sampler are detailed in Supplementary Section S14.

Alternative priors. Four alternatives keep the likelihood and the Gibbs allocation step. (i) A global–local prior for voxel intensities, λj∣bj∼Gamma⁡(a,bj)\lambda_j \mid b_j \sim\operatorname{Gamma}(a,b_j), bj∣ϕ∼Gamma⁡(c,ϕ)b_j \mid\phi\sim\operatorname{Gamma}(c,\phi), with a half-Cauchy-type global scale ϕ\phi (the TPBN family [28]; a=c=1/2a=c=1/2 is the horseshoe analog [29]), so that all conditionals remain Gamma. Such polynomial-tailed global–local priors attain posterior contraction in sparse exponential-family models, including count responses [30]. (ii) A Gaussian Markov random field on the log intensities with a half-Cauchy smoothing scale. (iii) For the region model, shrinkage of the rods’ log η\eta toward a common value, log⁡νr=log⁡(Qrθ2γ)+μ+δr\log\nu_r=\log(Q_r\theta^{2\gamma})+\mu+\delta_r, where θ2γ\theta^{2\gamma} is the fitted two-photon activity density, μ\mu a common level (flat prior) and δr∣τ,ψr∼N(0,τ2ψr)\delta_r\mid\tau,\psi_r\sim N(0,\tau^2\psi_r), so that ηr=eδr−δ0\eta_r=e^{\delta_r-\delta_0}; the global scale is τ∼C+(0,1)\tau\sim C^+(0,1) and the local scales are ψr=1\psi_r=1 (Gaussian) or ψr1/2∼C+(0,1)\psi_r^{1/2}\sim C^+(0,1) (horseshoe), updated through inverse-gamma auxiliaries [31]. (iv) A physics-informed version: through the three-photon fraction [32], the o-Ps contrast δ=log⁡(IτoPs)−log⁡(IτoPs)water\delta=\log(I_{\tau_{\mathrm{oPs}}})-\log(I_{\tau_{\mathrm{oPs}}})_{\mathrm{water}} (intensity II, lifetime τoPs\tau_{\mathrm{oPs}}) gives ηr=g(δr)/g(δ0)\eta_r=g(\delta_r)/g(\delta_0), g(δ)=w0+(1−w0)eδg(\delta)=w_0+(1-w_0)e^\delta, with w0≈0.4w_0\approx0.4 the direct-annihilation share of three-photon decays in water (a physical floor); δr\delta_r is shrunk toward water with τ∼C+(0,0.3)\tau\sim C^+(0,0.3), a scale set by tissue contrasts [33]. Details are in Supplementary Section S17.

The enhancement ratio relative to reference region 0 is

ηr=θr3γ/θr2γθ03γ/θ02γ.(8)\eta_r=\frac{\theta_r^{3\gamma}/\theta_r^{2\gamma}}{\theta_0^{3\gamma}/\theta_0^{2\gamma}}. \tag*{(8)}

Here θr3γ\theta_r^{3\gamma} and θr2γ\theta_r^{2\gamma} are the three- and two-photon activity densities of region rr, and region 0 is the reference (water in the porous phantom, the 5 mm rod in the four-rod phantom). The ratio θ3γ/θ2γ=f3/(1−f3)\theta^{3\gamma}/\theta^{2\gamma}=f_3/(1-f_3) follows the three-photon fraction, and the normalization cancels absolute activity and detection efficiency. We evaluate this functional for every posterior draw and report the posterior median and equal-tailed 95% interval. The image summary is a posterior mean. In simulations, two-photon uncertainty is approximated on the log-intensity scale; in the measured analysis, fitted two-photon intensities are fixed. Reported experimental intervals are therefore conditional statistical intervals.

Maximum Likelihood, MLEM, and Loss

For fixed response and background, the same likelihood yields the MLEM update

λj(t+1)=λj(t)qj∑iaijmi(t).(9)\lambda_j^{(t+1)}=\frac{\lambda_j^{(t)}}{q_j}\sum_i\frac{a_{ij}}{m_i^{(t)}}. \tag*{(9)}

Regional MLE uses the class densities and region geometry of the Bayesian fit with expected instead of sampled allocations; it differs from voxel MLEM stopped at 50 iterations, whose iteration number acts as an implicit regularizer.

ML as a limit of the posterior: EM is a minorize–maximize algorithm [34] whose M-step uk=∑iwik/qku_k=\sum_i w_{ik}/q_k, with expected labels wikw_{ik}, is the mode of the Gibbs conditional Gamma⁡(ak+nk,bk+qk)\operatorname{Gamma}(a_k+n_k,b_k+q_k) under the flat prior ak=1a_k=1, bk=0b_k=0: ML3 is the flat-prior posterior mode with sampling replaced by expectation. With a fixed number of parameters, an interior truth and many counts per class, the posterior is approximately normal about the MLE [35]; the median of log⁡ηr\log\eta_r then differs from the MLE by about 16(1/nr−1/n0)\frac{1}{6}(1/n_r-1/n_0), against a posterior SD of about (1/nr+1/n0)1/2(1/n_r+1/n_0)^{1/2}. This holds for the regional model, not for voxel images, whose dimension is comparable to the counts, nor at the boundary λj=0\lambda_j=0, where the difference is of the order of the SD (Supplementary Section S14).

For any loss, the Bayes action minimizes the posterior expected loss and, under a proper prior, has the smallest Bayes risk; it need not have lower risk at every truth. Squared error is not natural for Poisson intensities, whose variance grows with the mean, or for ratios. Poisson-adapted losses give other Bayes actions (Supplementary Table S16): for a count N∼Poisson⁡(sθ)N\sim\operatorname{Poisson}(s\theta) with known exposure ss, the Kullback–Leibler loss

LKL(θ,d)=s{d−θ+θlog⁡(θ/d)}=KL⁡{Po⁡(sθ)∥Po⁡(sd)}(10)L_{\mathrm{KL}}(\theta,d)=s\{d-\theta+\theta\log(\theta/d)\}=\operatorname{KL}\{\operatorname{Po}(s\theta)\mathbin{\|}\operatorname{Po}(sd)\} \tag*{(10)}

gives the posterior mean, the squared log error the geometric mean and Stein’s loss 1/E[θ−1∣Y]1/E[\theta^{-1}\mid Y]. For η\eta we report the posterior median, the Bayes action for the absolute log error; it requires only E∣log⁡η∣<∞E|\log\eta|<\infty, whereas the posterior mean of a ratio may not exist.

The loss decides whether a prior can dominate the MLE (Supplementary Section S13). For N∼Poisson⁡(sθ)N\sim\operatorname{Poisson}(s\theta) the half-count posterior mean (N+1/2)/s(N+1/2)/s has a mean squared error larger than that of N/sN/s by 1/(4s2)1/(4s^2), yet under (10) the MLE, zero with probability e−sθe^{-s\theta}, has infinite risk and every Gamma posterior mean with positive shape dominates it. For p≥2p\ge2 Poisson means, shrinkage dominates the MLE under normalized squared error [36] (risk 2.32 against 4 at means (0.2,0.5,1,2)(0.2,0.5,1,2), 3.97 at (50,…,80)(50,\ldots,80)), so gains are appreciable only at a few expected counts per parameter (voxels, not regions).

Simulation Design

Two simulation levels separate ideal response calibration from transport and background effects. The full-absorption surrogate generates Ore–Powell photon energies and isotropic decay planes [37], models pixel geometry and photon interactions, and applies measured-energy noise and selection. The HR-GAGG modules contain 8×88\times8 pixels of 2.5×2.5×9 mm32.5\times2.5\times9\ \mathrm{mm}^3 at 3.2 mm pitch. The measured energy response is FWHM⁡/E=513.3E−1.94+0.104\operatorname{FWHM}/E=513.3E^{-1.94}+0.104, with EE in keV. Scanner geometries, idealized response variants, and validation against the companion scanner study [18] are specified in Supplementary Section S1. Reported radial, tangential, and axial widths agree within 5.2%.

A porous-material phantom has water and XAD-4 compartments at (∓15,0)(\mp15,0) mm with η=1.75\eta=1.75, the value expected from positronium lifetimes in XAD-4 [6], 300, 1000, or 3000 expected selected signal events, with and without two-photon scatter, and a configuration with water at the center; a four-compartment simulation evaluates slice-wise and volumetric reconstructions (Supplementary Table S6).

The transport-based four-rod simulator, a custom Monte Carlo model (not Geant4), includes 18F^{18}\mathrm{F} positron range, water and PLA walls, partial deposition, inter-pixel and inter-module Compton scatter, Gd fluorescence, energy smearing, timing walk, and accidental coincidences. The phantom comprises 2, 3, 4, and 5 mm diameter water cavities with 2 mm walls and bottoms on a 3 mm base; the cavities are 7 mm deep. The simulator sums deposits within modules, whereas the measurement sorts pixel hits.

Pools of 2.5×1072.5 \times10^7 three-photon and 5×1075 \times10^7 two-photon decays per rod are simulated once; each dataset is a Poisson resample of the pools with independent read-out noise, so pool fluctuations are common to all datasets of a setting; five settings were repeated with six independent pool realizations (Supplementary Table S14). Labeled templates from a separate pool calibrate the response and background. Random triples are scaled to a late-to-prompt ratio of 0.88 for measured triples from three distinct modules, a working assumption. Thirty datasets per setting evaluate background, count level, contrast, wall fraction, response mismatch, and template size. Full generation and selection details are in Supplementary Section S12.

Measured and Geant4 Four-Rod Data

Fujimoto et al. measured four rods of 2, 3, 4 and 5 mm diameter at 15 mm from the axis, filled with 18F^{18}\mathrm{F}-FDG of uniform concentration (2.45 MBq in total), with a two-ring prototype (16 modules, 1024 pixels) [38]. Because every rod holds the same solution, η=1\eta= 1 for every rod unless annihilations in the rod walls change the three-photon fraction. The 3D-printed cavities are about 7 mm long; effective lengths fitted from the two-photon data are model parameters. The data comprise 4 600 098 triple coincidences (100–450 keV per photon, total 920–1124 keV, t13<100t_{13} < 100 ns), 15 449 794 pairs (485–537 keV) and 4119 Geant4 triples with the decay mode of each photon (912 three-photon). Unlike the phantom, the Geant4 model has polyvinyl alcohol walls, 250 keV positrons, ortho-positronium only in water (two-photon wall annihilations) and no base plate (Supplementary Section S9). The triples were sorted from pixel hits without module summation, with one time offset per module and no walk correction; two hits in one module occur in 73.6% of the prompt triples with Etot≥985E_{\mathrm{tot}} \ge985 keV before the vertex selection and 10.1% after it. Pixel numbering and module orientations were inferred from the two-photon likelihood and confirmed by the detector group (Supplementary Section S9).

Two-photon model. Pairs are binned by pixel pair (506 143 distinct pairs) in a prompt (∣Δt∣<20|\Delta t| < 20 ns) and a delayed (50–100 ns) window. The line-of-response density for a decay in rod rr is a Gaussian tube (SD 1.2 mm) integrated over the rod, and a diffuse cylinder absorbs activity outside the rods. EM gives the rod counts, with randoms removed through the delayed window; rod centers and axial extents were fitted by profile likelihood.

Three-photon model. For prompt triples (t13<40t_{13} < 40 ns, Etot≥985E_{\mathrm{tot}} \ge985 keV, valid vertex in a 56×56×2856 \times56 \times28 mm3^3 box) we use the region model with the 3-D kernel N(V⃗i,ΣE+ΣH)\mathcal{N}(\vec{V}_i,\Sigma_E+\Sigma_H), a selection-aware axial sensitivity from the surrogate, and three non-rod classes with normalized energy–position densities: a uniform diffuse three-photon class that absorbs events reconstructed far from every rod (about 30% of the true three-photon events in Geant4), a two-photon scatter class from the Geant4 events labeled two-photon, and a randoms class from the late window 60≤t13≤10060 \le t_{13} \le100 ns, treated as random-dominated (for three different modules, t13t_{13} is flat within 5% beyond 40 ns). Temporal flatness alone does not exclude delayed true events, so late-window contamination is an unresolved source of systematic uncertainty. The energy density pEp_E is a kernel estimate on the Geant4 three-photon events. ΣE\Sigma_E and ΣH\Sigma_H were scaled by factors chosen by the likelihood on the measured events (1.5 and 2.0), which also absorb PSF tails and residual geometry errors.

Refinements from the simulation. The simulator showed that the Gaussian kernel misses heavy-tailed vertex errors (Sec. III-D); the refined model B3 used in the simulation study (1) replaces the kernel by a scale mixture ∑kπkN(V⃗i,ck(ΣE+ΣH))\sum_k \pi_k\mathcal{N}(\vec{V}_i,c_k(\Sigma_E+\Sigma_H)) fitted by EM to the true vertex errors of labeled simulations, without a diffuse class; (2) anchors the scatter class to the rods, using the template distribution of the reconstructed vertex about the decay rod weighted by the two-photon counts; (3) blurs the rods by the 18F{}^{18}\mathrm{F} positron range; and (4) enters the expected randoms of each pixel pair as a known term in the two-photon EM, with pair efficiencies from the simulation (Supplementary Section S12). B3-G, without refinement 1 (Gaussian kernel and diffuse class), is the study’s counterpart of the initial measured-data model; the heavy-tailed measured-data variants introduce refinement 1 only. A complete three-photon fit takes about 12 s on two CPU cores [39] (Supplementary Section S10). The ROI estimator (M1) is our implementation of the method of [6]: kernel deposition with ΣE\Sigma_E for Etot≥985E_{\mathrm{tot}} \ge985 keV and t13<100t_{13} < 100 ns, a two-photon MLEM image blurred to the three-photon resolution, ROIs of radius rphys+f×FWHMr_{\mathrm{phys}} + f \times\mathrm{FWHM} (f=0.5f = 0.5, 1; FWHM 4.1 mm from the median covariance), and η\eta from the ROI count ratios.

Estimators and Evaluation

Event level: (a) energy term with exact hits; (b) hit term with true energies; (c) current practice, pixel hits with the in-plane ΣE\Sigma_E; (d) ΣE+ΣH\Sigma_E + \Sigma_H; plug-in Monte Carlo propagation; and the event posterior. Coverage is the fraction of events with squared Mahalanobis distance below the χd2\chi^2_d quantile; it checks each event’s Gaussian kernel, not the Poisson counts (Supplementary Section S6). ROI level: M1, our implementation of the published-style pipeline (985 keV cut, ΣE\Sigma_E deposition, sensitivity-normalized two-photon image, ROI radius 2σ2\sigma of each region’s width, Poisson interval); M2, list-mode MLEM with ΣE+ΣH\Sigma_E + \Sigma_H and sensitivity; B2, the voxel model with background class; B3, the region model (with background class, all selected events); and, for the four-rod phantom, BS, an emulation of a system-matrix method with an energy-neighborhood filter and independent 2-D reconstructions per zz slice. ML3 is the regional MLE under the same event-by-class likelihood matrix, sensitivities and two-photon denominator as B3 in the same dataset: EM with SQUAREM [40] to a relative change below 10−910^{-9}, with a delta-method 95% interval on log η\eta from the observed information (Supplementary Section S14). B3-mean is the posterior mean of η\eta. On the measured data a cluster bootstrap resamples the groups of triples that share a hit. Simulated four-rod study (Sec. II-D): for each setting of Table III, 30 datasets of T=4000T = 4000 s, which hold about 9 000 selected true three-photon triples (about a quarter as many at T/4T/4 and with the module response). Each dataset has its own labeled template simulation, so the template noise enters the comparison. The methods are B3, B3-G, B3 without the scatter and randoms classes (rods and a diffuse class only), ML3 and B3-mean under the likelihood of B3, and M1 with ROIs of r+0.5r + 0.5 and r+1r + 1 FWHM.

setting (datasets)B3 bias [%] 2B3 bias [%] 3B3 bias [%] 4 mmB3 coverage 2B3 coverage 3B3 coverage 4 mmB3-G bias [%] 2B3-G bias [%] 3B3-G bias [%] 4 mmM1 (r+0.5r + 0.5 FWHM) bias [%] 2M1 (r+0.5r + 0.5 FWHM) bias [%] 3M1 (r+0.5r + 0.5 FWHM) bias [%] 4 mm
reference (30)+8.8+0.7−1.00.530.930.90−8.3−5.6−3.0+21−5−8
acquisition time / 4 (30)+28.2+6.9+1.40.230.830.97−3.7−3.5−1.0+22−4−7
no scatter or randoms (30)+1.9+1.4−1.00.900.970.93−3.9−2.0−2.4−6−10−8
η=1.36,1.20,1\eta= 1.36, 1.20, 1 (30)+6.1+0.5−1.30.670.970.90−7.0−3.6−3.0+8−8−7
wall three-photon fraction ×2 (30)+6.0+0.3−0.80.670.900.83−8.2−5.0−2.6+12−7−6
module response 0.3–1 (30)+24.5+19.4+12.50.370.130.47−12.4+6.5+8.9+15+6+4
resolution 22% wider than assumed (30)+10.2+1.2−0.80.530.971.00−11.1−5.7−3.6+33−2−7
templates ×20 (30)+7.3+1.0−1.00.800.900.87−7.8−4.1−2.9+21−4−7
randoms at the measured level (30)+41.1+7.6+2.50.000.330.87−16.3−10.8−3.8+92+16−3
randoms 2× measured (30)+76.0+18.3+6.00.000.000.37−21.3−11.1−5.3+132+31−2

Table III. Transport-based simulation of the four-rod measurement: relative bias [%] of η^\hat{\eta} and coverage of the 95% interval for the 2, 3 and 4 mm rods (relative to the 5 mm rod) over repeated datasets (number in parentheses) of one pool realization (six realizations: Table S14). Each dataset has T=4000T = 4000 s at 2.45 MBq (about 9 000 selected true three-photon triples; four times fewer at T/4T/4 and with the module response) and its own Geant4-sized labeled template simulation. Reference: η=1\eta= 1, random triples at 1/6 of the measured level. B3: region model with the heavy-tailed kernel calibrated on the template simulation; B3-G: Gaussian kernel and diffuse class (closest counterpart of the measured-data model); M1: ROI estimator. All methods and statistics: Table S15.

Results

Event-Level Coverage and the Hit-Position Term

With exact hits, the energy-only covariance covers 0.68 of events at the nominal 68% and 0.92 at 95% (Table I, Figure 1). With pixel hits it covers only 0.85 in the small-animal scanner, and the deficit grows as the energy resolution improves: 0.13 at 1% and 0.74 at 5%. At the GAGG response the hit term accounts for 8% of the in-plane and 22% of the axial variance. Adding ΣH\Sigma_H restores the 95% coverage to 0.94–0.97 for all energy models and positions, and the axial 95% interval to 0.96 (energy-only 0.89). The PSF predicted by drawing one error per event from N(0,Σi)\mathcal{N}(0,\Sigma_i) reproduces the empirical variance W76W_{76} with a median of 1.01 (5–95%: 0.98–1.04) (energy-only: 0.91 (5–95%: 0.21–1.03)), a test applicable to measured point sources. Selecting on measured energies lowers the 95% coverage to 0.92 (0.92 without an upper edge), because events with true Emax⁡>450E_{\max} > 450 keV enter with better-conditioned measured energies. The first-order covariance agrees with Monte Carlo propagation (SD ratio 1.02–1.04), an auxiliary event posterior with Gaussian energy errors and latent hit positions (Supplementary Section S5) covers 0.947–0.957, and a common gain error leaves every vertex unchanged (Supplementary Tables S3 and S4).

Figure 1. Event-level calibration. (a) Quantiles of Fχ2(D2)F_{\chi^2}(D^2) against the nominal level (small-animal center, GAGG, measured-energy selection). (b) Coverage of the nominal 95% region for the energy-only and energy+hit covariance (mean and range over nine positions; filled: true-energy, open: measured-energy selection). (c) Coverage by measured Emax⁡E_{\max} without an upper edge (50–550 keV). (d) Predicted vs. empirical W76W_{76}.

scannerselectionnposn_{\mathrm{pos}}(a) EE, exact hits(b) hits, true EE(c) current(d) EE+hitaxial (c)axial (d)pred./emp.
smalltrue EE90.68/0.920.66/0.970.55/0.850.69/0.950.890.961.02
smallmeasured EE90.64/0.900.66/0.970.52/0.820.65/0.920.860.940.95
smallno upper edge90.63/0.860.65/0.960.45/0.720.67/0.920.880.941.04
braintrue EE30.68/0.920.66/0.970.66/0.920.67/0.930.950.961.01
brainmeasured EE30.64/0.890.66/0.970.62/0.890.63/0.900.920.930.93
humantrue EE30.68/0.920.66/0.970.68/0.920.67/0.930.950.961.03
humanmeasured EE30.64/0.890.65/0.970.64/0.890.63/0.900.920.930.93

Table I. Event-level coverage (nominal 68%/95%) of the propagated covariance, measured GAGG response, averaged over source positions (nposn_{\mathrm{pos}}). (a) Energy term with exact hits; (b) hit term with true energies; (c) current practice: pixel hits, energy-only 2×22 \times2 in-plane covariance; (d) proposed: pixel hits, ΣE+ΣH\Sigma_E+\Sigma_H (3-D). Axial: coverage of the 1-D 95% interval on zz. Last column: W76W_{76} (radial) predicted from the covariances of (d) divided by the empirical W76W_{76}.

Kernel Deposition and Voxel-Level Uncertainty

Depositing each event with its energy-only kernel broadens the image by 1+fE\sqrt{1+f_E}, if the energy share of the variance, rather than by 2\sqrt{2}, because the hit term is missing from the kernel (Supplementary Section S16). This predicts 1.386 for GAGG against 1.375 in the companion Geant4 study [18] and 1.054, 1.330, 1.382, 1.371 here, with no free parameter (Fig. S3). In the voxel model the 95% intervals of single 2 mm voxels cover the truth in only 32% of cases (28% with background), so voxelwise uncertainty is not calibrated at this resolution, whereas the activity in a 6 mm disc is recovered to 99% (97%) (Fig. S4).

Porous-Material Phantom

Table II compares the estimators of η\eta over repeated datasets (all estimators and figures: Supplementary Section S7). In the symmetric phantom without background and with 3000 events every estimator is within 1.5% of ηtrue\eta_{\mathrm{true}}. The published-style ROI pipeline (M1) has bias +0.8% and a slightly conservative interval (coverage 0.97), because it treats the ROI integrals of a kernel-deposited image as independent Poisson counts. The region model (B3), which uses all selected events with their likelihood weights, has bias −0.5%, an SD about 10% smaller than M1 and 95% coverage of 0.95–0.96 from 300 to 3000 events, with intervals 18–19% narrower. The 3000-event RMSE is 0.067 for both B3 and matched regional MLE (ML3), versus 0.094 for 50-iteration voxel MLEM (M2). M2 also differs in events, grid and ROIs; with those of the voxel Bayesian model, 50-iteration MLEM matches B3 (Sec. III-F). With the water compartment at the center, efficiency and recovery no longer cancel: M1 is biased by −3.3% and covers 0.87, whereas B3, which estimates activity densities with the selection-aware sensitivity, has bias +0.0% and coverage 0.93. With one background event per true event, the background class reduces the bias from −2.8% to −0.6% (coverage 0.86 to 0.94).

EventsMethodBiasSDRMSECov. 95%
3000M1+0.0150.0740.0750.97
3000M2−0.0160.0930.094—
3000ML3−0.0100.0660.0670.96
3000B3−0.0100.0670.0670.96
1000M1+0.0220.1350.1360.96
1000M2+0.1510.2020.252—
1000ML3+0.0050.1170.1170.95
1000B3+0.0050.1170.1170.95
300M1+0.0120.2580.2580.96
300M2−0.0550.3350.338—
300ML3+0.0100.2250.2250.96
300B3+0.0090.2250.2240.96

Table II. Porous-material simulation (η=1.78\eta=1.78): repeated-dataset results, 200 replicates per displayed configuration. M2 is 50-iteration voxel MLEM; ML3 is matched regional MLE; B3 is Bayesian regional inference. Values are on the ratio scale.

Transport-Based Simulation of the Four-Rod Measurement

Vertex errors. The propagated covariance does not describe the vertex errors of realistic data. Under ΣE+ΣH\Sigma_E + \Sigma_H the selected true three-photon triples are covered at 68% and 95% in only 0.44 and 0.70 of cases. In-plane errors have a median of 3.4 mm but 90th and 99th percentiles of 9.0 and 20 mm (scatter in the detector and the phantom). A three-component scale mixture fitted on a 20 times larger labeled simulation (π=0.68,0.27,0.05;τ=1.2,5.4,35.4\pi=0.68, 0.27, 0.05; \tau=1.2, 5.4, 35.4) covers 0.67 and 0.94 on independent events; in the study B3 refits it on each dataset’s template.

Moderate randoms. Table III summarizes the study.

  • Reference setting. B3 has biases of +8.8, +0.7, −1.0% for the 2, 3 and 4 mm rods and 95% coverage of 0.53, 0.93, 0.90; without background triples, +1.9, +1.4, −1.0% (0.90, 0.97, 0.93). Six-realization means: +8.8, +1.3, +0.5% (0.52, 0.88, 0.88) and +3.2, +1.2, +0.2% (0.88, 0.91, 0.93). Each background class alone biases the 2 mm rod (scatter only: +13%; randoms only: +7%).

  • B3-G is biased by −8.3, −5.6, −3.0%: the Gaussian kernel and diffuse class move tail events out of the rods.

  • The ROI estimator is biased by +21.4, −4.9, −7.5% (r+0.5r + 0.5 FWHM) and +48.1, +6.6, −1.5% (r+1r + 1 FWHM); its Poisson interval covers 0.00, 0.83, 0.30 and 0.00, 0.60, 1.00.

  • Other settings (Table S15) keep the bias pattern of the reference; with templates 20 times larger the 2 mm bias is +7.3% (coverage 0.80, 0.90, 0.87).

  • Two settings bias B3. At T/4T/4 B3 is biased by +28.2, +6.9, +1.4%, because the late-window randoms template, taken from the dataset, is four times sparser (randoms only: +23%); over six pool realizations the 2 mm bias averaged 20.1% (range 10.1–28.2%; this one is the largest). An unmodeled module response (+24.5, +19.4, +12.5%) also lowers the counts fourfold and breaks the proportionality of three- and two-photon sensitivities (without random triples: +9, +12, +8%).

  • Matched ML. In each dataset ML3 maximizes the likelihood that B3 samples. Over the 10 settings the relative biases of ML3 and B3 differ by at most 0.1 percentage points (0.14 over six pool realizations) and their RMSE ratio (B3/ML3) is 0.99–1.02 (Supplementary Table S17); at the reference ML3 has biases of +8.9, +0.7, −1.0% and coverage 0.50, 0.93, 0.93. The background biases above are properties of the likelihood, not of the prior.

Measured randoms. At the measured late-to-prompt ratio (0.88; measured 0.88) every method is biased for the 2 or the 3 mm rod (Figure 2b). For the 2 mm rod M1 gives 1.92 and 2.55 at the two ROI sizes, and 2.32 and 3.05 at twice the measured level (measured: 2.07 and 2.82; 2.28 and 3.00 with three different modules); B3-G gives 0.84 (measured 0.86, or 0.92 with three different modules), B3 1.41, and B3 without background classes 1.05 (3 mm rod: 0.93). The prompt window then holds 4.1 (2.82) random triples per true triple; the measurement has about 5.9 (Supplementary Section S12).

Figure 2. Transport-based simulation of the four-rod measurement. (a) Squared Mahalanobis distance of the true vertex errors of selected three-photon triples under ΣE+ΣH\Sigma_E+\Sigma_H, against the Gaussian (χ32\chi^2_3) and the calibrated scale-mixture predictions. (b) Estimates of η\eta for the 2 mm rod (truth 1) over 30 datasets of one pool realization at three levels of random triples (points; mean ±\pm SD), with the measured values of the closest counterparts (stars; B3: heavy-tailed kernel without refinements 2–4; B3-G: measured-data model). (c) Coverage of the 95% intervals of B3 (filled) and M1 at r+0.5r+0.5 FWHM (open) for the 2, 3 and 4 mm rods, by setting with randoms at 1/6 of the measured level or none.

Measured Four-Rod Data

Two-photon data. Randoms make up 8.3% of the prompt pairs. The fitted rod centers lie within 0.5 mm of the nominal positions; the axial centers are 3.5, 3.5, 4.0 and 3.5 mm and the lengths 4, 4, 5 and 4 mm for the 2, 3, 4 and 5 mm rods (1 mm grid). Relative to the 5 mm rod, the two-photon concentrations of the 2, 3 and 4 mm rods are 0.95, 0.92, 0.80 (0.94–0.95, 0.92 and 0.75–0.83 over the tube width, the rod length ±1 mm and the axial center ±0.5 mm). For nominal diameters and a uniform detector they would be 1; they absorb deviations of the actual rod volumes and of the detector normalization, which cancel in η\eta only to the extent that they affect both photon counts alike. The 0.80 of the 4 mm rod mostly reflects its longer fitted length (5 vs. 4 mm); with the nominal geometry it is 0.99, and η\eta changes little because the three-photon concentration moves with it.

Enhancement ratio. With the corrected pixel map, the ROI pipeline gives η=2.07,1.08,1.27\eta= 2.07, 1.08, 1.27 for ROIs padded by half the FWHM and 2.82, 1.38, 1.31 for a full FWHM (Table IV), so the values depend strongly on the ROI size. The region model (main analysis: Etot≥985E_{\mathrm{tot}} \ge985 keV, t13<40t_{13} < 40 ns, calibrated covariance, 73 254 events, of which 6674 are assigned to the rods, 12 494 to the diffuse three-photon class, 26 176 to scatter and 27 914 to randoms) gives η=0.86\eta= 0.86 [0.75, 0.98] (2 mm), 0.68 [0.62, 0.76] (3 mm) and 0.98 [0.93, 1.05] (4 mm). Across the analysis variants with Etot≥985E_{\mathrm{tot}} \ge985 keV or ≥1000\ge1000 keV the medians range over 0.81–1.15, 0.63–0.79 and 0.96–1.05; using all energy sums, where scatter and randoms are 6 times more numerous, moves them to 0.55, 0.53, 0.85. The 3 mm rod is below 1 in every variant. The model-based values are therefore much closer to 1 than the ROI values for the smallest rod, but the 95% intervals are statistical only: the spread across reasonable background and energy models is of the same size as the interval width, and the variants disagree most where the signal is weakest. Figure 3g shows a second limitation: the share of 100–450 keV photons that a module records, relative to its share of 511 keV photons, varies between 0.32 and 1.42 across modules, so the three-photon and two-photon sensitivities of a rod are not proportional and do not cancel exactly in η\eta. A first-order correction from these hit rates changes η\eta by −14%, −1%, −5% for the 2, 3 and 4 mm rods; a normalization measurement is needed to replace it.

2 mm3 mm4 mm
ROI estimator (M1, our implementation of the method of [6])
M1, ROI r+0.5r + 0.5 FWHM2.071.081.27
M1, ROI r+1.0r + 1.0 FWHM2.821.381.31
Bayesian region model (median [95% interval])
Gaussian kernel, diffuse class (main): Etot≥985E_{\mathrm{tot}} \ge985 keV, t13<40t_{13} < 40 ns0.86 [0.75, 0.98]0.68 [0.62, 0.76]0.98 [0.93, 1.05]
covariance scales not calibrated (1, 1)0.81 [0.70, 0.93]0.66 [0.59, 0.73]0.97 [0.91, 1.03]
all EtotE_{\mathrm{tot}} (920–1124 keV)0.55 [0.45, 0.65]0.53 [0.48, 0.59]0.85 [0.80, 0.90]
3γ3\gamma energy density from the surrogate MC0.98 [0.86, 1.12]0.73 [0.66, 0.81]1.03 [0.96, 1.09]
no diffuse 3γ3\gamma class0.93 [0.82, 1.05]0.71 [0.65, 0.77]0.99 [0.93, 1.05]
heavy-tailed kernel (simulation-calibrated), no diffuse class1.02 [0.92, 1.14]0.74 [0.67, 0.80]1.02 [0.96, 1.08]
heavy-tailed kernel, scales (1.5, 2.0), no diffuse class1.08 [0.97, 1.20]0.76 [0.70, 0.82]1.04 [0.98, 1.09]
heavy-tailed kernel with diffuse class0.84 [0.73, 0.96]0.66 [0.60, 0.74]1.00 [0.94, 1.07]
main ×\times module-efficiency proxy0.74 [0.64, 0.85]0.68 [0.61, 0.75]0.93 [0.88, 0.99]

Table IV. Measured four-rod phantom (uniform FDG concentration, so η=1\eta= 1 for every rod unless the rod walls change the three-photon fraction): enhancement ratio of the 2, 3 and 4 mm rods relative to the 5 mm rod. ROI values have no interval. Bayesian rows: posterior median and 95% interval of the three-photon concentration ratio divided by the two-photon concentration ratio of the same geometry (statistical only; the two-photon systematic range is given in the text). All variants: Table S13.

Figure 3. Measured four-rod phantom (corrected pixel map). (a) Two-photon list-mode MLEM image of the prompt pairs. (b) Kernel deposition (ΣE+ΣH\Sigma E + \Sigma H) of all prompt triples in the analysis box with Etot≥985E_{\mathrm{tot}} \ge985 keV and ∣z−3.5∣≤8|z - 3.5| \le8 mm. (c) The same events weighted by their posterior probability of belonging to a rod (main region model). (d) Three-photon image of the ROI pipeline (energy-only kernels, all t13t_{13}). Square-root scale; dashed circles: fitted rod positions and nominal diameters. (e) Enhancement ratio of the 2, 3 and 4 mm rods by method (ROI: the pipeline of (d); model: the region model; dashed: nominal equal-ratio reference); Bayesian estimates with 95% intervals. (f) Geant4: three-photon concentration ratios (truth 1) from the labeled true events, from the region model on all events, and from the ROI estimator. (g) Ratio of each module’s share of photons in prompt triples to its share in pairs, a proxy for the response at 100–450 keV relative to 511 keV; labels mark the module that each rod faces.

Heavy-tailed kernel. With the kernel calibrated on the simulation and no diffuse class, the region model gives 1.02 [0.92, 1.14], 0.74 [0.67, 0.80], 1.02 [0.96, 1.08] for the 2, 3 and 4 mm rods, and 0.84 with a diffuse class (Table IV). A diffuse class raises the measured log-likelihood by 3 177, but it does so also on simulated datasets without diffuse activity (by 5 300–7 800, moving the 2 mm rod from 1.37 to 0.87): it absorbs template misfit rather than indicating diffuse activity. With three different modules, as in the simulation, the model gives 1.07 [0.95, 1.19], 0.76 [0.69, 0.83], 1.03 [0.97, 1.09] (Table S13), and M1 rises to 2.28 and 3.00 for the 2 mm rod, so the same-module triples do not cause the high ROI values.

Matched maximum likelihood and shared hits. Maximizing the same likelihood (ML3) changes η\eta by at most 0.008 in any measured variant; with the heavy-tailed kernel ML3 gives 1.024, 0.737, 1.021, with a 2 mm Wald interval of [0.91, 1.15] against the credible interval [0.92, 1.14] (Supplementary Table S18). The measured deviations from η=1\eta= 1, including the 3 mm deficit, are therefore properties of the likelihood kernel, classes, sensitivities, not of the half-count prior. The 73 254 selected triples form 69 205 hit-sharing groups. A cluster bootstrap over these groups gives SDs 0.91–1.08 times the posterior SDs (Supplementary Table S19), within bootstrap error: hit reuse barely affects the analysis selection.

Priors and Losses

With identical events, kernel, sensitivity, 2 mm voxels and 6 mm ROIs, η\eta in the porous-material phantom was insensitive to the prior: at 1000 events the RMSE was 0.133 (Gamma(0.05)), 0.133 (horseshoe-type TPB), 0.136 (Gaussian MRF), 0.132 (converged voxel ML), and 0.132 (50-iteration MLEM), within Monte Carlo error also at 300 and 3000 events (Supplementary Table S21). The images differ: under the Poisson KL error, converged voxel ML is one to two orders of magnitude worse than any posterior mean, as Section II-C predicts; the Gaussian MRF reduced the error to 0.57–0.62 times that of the Gamma(0.05) prior and was best at 300 events (147 vs. 171 for MLEM), whereas 50-iteration MLEM was lower at 1000 and 3000 events and the sparsity-favoring TPB priors were worst (Supplementary Fig. S8). In the four-rod study, shrinking the rods’ log η\eta toward a common value lowered the RMSE (2, 3, 4 mm) from 0.104, 0.035, 0.027 to 0.068, 0.026, 0.019 at the reference and from 0.054, 0.036, 0.026 to 0.027, 0.019, 0.015 without background, where the truth is uniform, and changed it little for strongly unequal ratios (0.130, 0.032, 0.030 vs. 0.124, 0.033, 0.030; Supplementary Table S23). The physics-informed horseshoe prior was the most accurate without background (0.024, 0.017, 0.015) but, with its tighter physical scale, cost accuracy for strongly unequal ratios (0.156, 0.069, 0.028) and in the two-region porous phantom. On the measured data shrinkage moved η\eta by at most 0.03, insensitively to w0w_0.

Discussion

Contribution. The MLE comparators are statistical benchmarks, not a relabeling of the published pipeline [6], in which MLEM reconstructs only the two-photon image.

Source of the improvement. Weak-prior regional inference should approach matched ML when information is sufficient, and it does: in every simulated setting and on the measured data B3 and ML3 agree closely, and with matched events, grid and ROIs 50-iteration MLEM matches them as well. B3 and ML3 share the model bias (relative to the Kullback–Leibler projection of the truth onto the model) and the sampling error, and differ by the O(1/n)O(1/n) effect of the half-count prior, below Monte Carlo error down to about 10 counts in the 2 mm rod (Supplementary Sections S13 and S14). Gains over M1 and voxel MLEM thus come from the regional likelihood (event weighting, selection-aware sensitivity, known boundaries, background classes) and the event selection, not from the prior; the posterior adds intervals for functionals.

Where a prior matters. Regional classes hold hundreds to thousands of events, so no prior acting on each region changes η\eta; voxels hold few, so the prior governs the image and must match the object. Shrinkage across regions helps when the ratio is shared but does not remove the background bias.

Measured phantom and calibration toward η=1\eta= 1. The heavy-tailed model is closer to one than the ROI analysis for the 2 and 4 mm rods and farther for the 3 mm rod, which faces a module with low relative response and gain drift. On labeled Geant4 data the model recovers the true concentration ratios (Figure 3f), so the deviations arise in the measurement chain or the walls. Calibrations measured independently of the phantom should bring every rod to η=1\eta= 1: (i) per-pixel energy calibration with gain tracking, walk correction and merging of split hits, so that the module facing the 3 mm rod (response proxy 0.32; Figure 3g) is treated like the others; (ii) module-wise three-photon sensitivities at 100–450 keV from a uniform-cylinder scan, replacing the proxy, which did not remove the deficit (Figure 3e); (iii) kernel widths and tails from point-source scans, instead of the factors fitted on the phantom; (iv) scans at two activities, separating randoms (quadratic in activity) from delayed true triples (linear) in the late window, and with the phantom rotated by 90∘90^\circ, so that a deficit that follows the module identifies a detector cause. A uniform phantom then serves as the acceptance test: every rod’s 95% interval should contain 1.

Use in theranostic decisions. For a decision threshold cc, such as one for choosing a β−\beta^- or an α\alpha-emitting agent, the posterior gives Pr⁡(ηr>c∣data)\Pr(\eta_r > c \mid\text{data}) with count, background and response uncertainty. Averaged over six pool realizations, coverage was 0.88, 0.91, 0.93 without background, 0.52, 0.88 at the reference and 0.00, 0.44, 0.69 at the measured randoms level, where the model itself is biased by 38.2% for the 2 mm rod (range 33.3–41.1%): neither sampling nor more MLEM iterations repair a misspecified response. Such decisions need lesions well above the resolution and a validated background model.

Uncertainty and generalizability. Measured intervals condition on the fitted geometry, response, templates and two-photon fit.

The simulator omits electron transport, Rayleigh scattering, pile-up, and dead time; template and kernel uncertainty are not fully propagated, thirty replicates give a coverage standard error of about 0.040, and the pool realization adds an error common to all datasets of a setting that the intervals omit (bias SD up to 6.6 percentage points; Supplementary Table S14). The undercoverage for 2 mm voxels prevents claims of calibrated voxelwise uncertainty, and regional results rely on known phantom structure.

Conclusion

A Bayesian response-based reconstruction provides regional intensity and enhancement-ratio inference for three-photon annihilation imaging. The regional estimator improves on the ROI and finite-iteration voxel MLEM pipelines; matched regional MLE performs similarly, so the gains derive from the regional likelihood. Priors changed voxel images substantially but regional ratios only when shrunk toward a common value. Because it needs only positron emission, the method applies to the imaging agents of radiotheranostic pairs, where threshold decisions require calibrated intervals. The 3 mm deficit and background sensitivity remain open.

Funding and Acknowledgments

Supported in part by National Science Foundation (NSF) grants DMS-1924792 and DMS-2318925 and by the National Institutes of Health (NIH), National Institute of Allergy and Infectious Diseases (NIAID), R01 award R01AI206603. This work was partially supported by JST CREST, Japan, Grant Number JPMJCR26C4. Analysis code accompanies this work. Conflict of interest: None declared. AI use: Claude (Anthropic) assisted with code and editing, checked by the authors.

References

References

  1. [1]H. Tashima and T. Yamaya, “Three-gamma imaging in nuclear medicine: A review,” IEEE Transactions on Radiation and Plasma Medical Sciences, vol. 8, no. 8, pp. 853–866, 2024.
  2. [2]C. Ericsson et al., “Nuclear medical imaging using β+γ coincidences from 44Sc radio-nuclide with liquid xenon as detection medium,” Nucl. Instrum. Methods Phys. Res. A, vol. 571, no. 1–2, pp. 142–145, 2007.
  3. [3]E. Yoshida, H. Tashima, K. Nagatsu et al., “Whole gamma imaging: a new concept of PET combined with Compton imaging,” Physics in Medicine & Biology, vol. 65, no. 12, p. 125013, 2020.
  4. [4]P. Moskal, K. Dulski, N. Chug et al., “Positronium imaging with the novel multiphoton PET scanner,” Science Advances, vol. 7, no. 42, p. eabh4394, 2021.DOI
  5. [5]J. Qi and B. Huang, “Positronium lifetime image reconstruction for TOF PET,” IEEE Transactions on Medical Imaging, vol. 41, no. 10, pp. 2848–2855, 2022.DOI
  6. [6]M. Fujimoto, R. Sato, M. Hamdan et al., “Advancing PET through direct imaging of three-photon decay using pure positron emitters,” Communications Physics, vol. 9, p. 254, 2026.DOI
  7. [7]K. Kacperski, N. M. Spyrou, and F. A. Smith, “Three-gamma annihilation imaging in positron emission tomography,” IEEE Transactions on Medical Imaging, vol. 23, no. 4, pp. 525–529, 2004.pubmed.ncbi.nlm.nih.gov/15084078
  8. [8]O. Sartor, J. de Bono, K. N. Chi et al., “Lutetium-177–PSMA–617 for metastatic castration-resistant prostate cancer,” New England Journal of Medicine, vol. 385, no. 12, pp. 1091–1103, 2021.DOI
  9. [9]K. Shibuya, H. Saito, F. Nishikido, M. Takahashi, and T. Yamaya, “Oxygen sensing ability of positronium atom for tumor hypoxia imaging,” Communications Physics, vol. 3, p. 173, 2020.DOI
  10. [10]P. Moskal, “Quantum entanglement degree, mean positronium lifetime, and the 3γ/2γ annihilation-rate ratio as novel PET biomarkers for hypoxia: concept, challenges, and predictions,” Bio-Algorithms and Med-Systems, vol. 22, pp. 56–77, 2026.DOI
  11. [11]G. W. Barendsen, C. J. Koot, G. R. van Kersen, D. K. Bewley, S. B. Field, and C. J. Parnell, “The effect of oxygen on impairment of the proliferative capacity of human cells in culture by ionizing radiations of different LET,” Int. J. Radiat. Biol., vol. 10, no. 4, pp. 317–327, 1966.
  12. [12]S. Poty, L. C. Francesconi, M. R. McDevitt, M. J. Morris, and J. S. Lewis, “α-emitters for radiotherapy: from basic radiochemistry to clinical studies—Part 1,” Journal of Nuclear Medicine, vol. 59, no. 6, pp. 878–884, 2018.DOI
  13. [13]H.-H. Huang, Z. Zhu, S. Booppsari, Z. Chen, S. Pang, and C.-M. Kao, “A statistical reconstruction algorithm for positronium lifetime imaging using time-of-flight positron emission tomography,” IEEE Transactions on Radiation and Plasma Medical Sciences, vol. 9, no. 4, pp. 478–486, 2025.DOI
  14. [14]Z. Chen, C.-M. Kao, H.-H. Huang, and L. An, “Enhanced positronium lifetime imaging through two-component reconstruction in time-of-flight positron emission tomography,” Frontiers in Physics, vol. 12, p. 1429344, 2024.DOI
  15. [15]B. Ulutlukt, N. Rathod, G. Gasparato et al., “Bayesian three-dimensional positronium lifetime estimation with a partial system matrix,” Statistics and Data Science in Imaging, 2026.
  16. [16]B. Ulutlukt, N. Rathod, G. Gasparato et al., “Voxel-wise Bayesian estimation for multi-population positronium lifetime imaging,” arXiv:2608.22205, 2026.
  17. [17]K. Kacperski and N. M. Spyrou, “Performance of three-photon PET imaging: Monte Carlo simulations,” Physics in Medicine and Biology, vol. 50, no. 23, pp. 5679–5695, 2005.DOI
  18. [18]M. Fujimoto et al., “Point-spread function of analytic three-photon vertex reconstruction towards positronium ratio imaging: effects of scanner geometry and energy response,” 2026, under review, Bio-Algorithms and Med-Systems.
  19. [19]N. Chug et al., “Studies of CPT symmetry in positronium decays with the 192 plastic strip J-PET detector,” Phys. Rev. D, vol. 113, p. 032003, 2026.arxiv.org/abs/2511.20098
  20. [20]L. Raczyński et al., “Ortho-positronium three-photon decays: physics constraints and a closed-form energy method for annihilation vertex reconstruction,” arXiv:2605.09174, 2026.arxiv.org/abs/2605.09174
  21. [21]L. Raczyński et al., “Three-photon Bayesian imaging of ortho-positronium,” arXiv:2607.27741, 2026.arxiv.org/abs/2607.27741
  22. [22]L. A. Shepp and V. Vardi, “Maximum likelihood reconstruction for emission tomography,” IEEE Transactions on Medical Imaging, vol. 1, no. 2, pp. 113–122, 1982.
  23. [23]L. Parra and H. H. Barrett, “List-mode likelihood: EM algorithm and image quality estimation demonstrated on 2-D PET,” IEEE Transactions on Medical Imaging, vol. 17, no. 2, pp. 228–235, 1998.DOI
  24. [24]P. J. Green, “Bayesian reconstructions from emission tomography data using a modified EM algorithm,” IEEE Transactions on Medical Imaging, vol. 9, no. 1, pp. 84–93, 1990.pubmed.ncbi.nlm.nih.gov/18222753
  25. [26]A. Sitek, “Representation of photon limited data in emission tomography using origin ensembles,” Physics in Medicine and Biology, vol. 53, no. 12, pp. 3201–3216, 2008.DOI
  26. [27]V. Pierlot and M. Van Droogenbroeck, “A new three object triangulation algorithm for mobile robot positioning,” IEEE Transactions on Robotics, vol. 30, no. 3, pp. 566–577, 2014.DOI
  27. [28]A. Armagan, D. B. Dunson, and M. Clyde, “Generalized beta mixtures of Gaussians,” in Advances in Neural Information Processing Systems 24, 2011, pp. 523–531.arxiv.org/abs/1107.4976
  28. [29]C. M. Carvalho, N. G. Polson, and J. G. Scott, “The horseshoe estimator for sparse signals,” Biometrika, vol. 97, no. 2, pp. 465–480, 2010.
  29. [30]S.-H. Wang, R. Bai, and H.-H. Huang, “Two-step mixed-type multivariate Bayesian sparse variable selection with shrinkage priors,” Electronic Journal of Statistics, vol. 19, no. 1, 2025.arxiv.org/abs/2201.12839
  30. [31]E. Makalic and D. F. Schmidt, “A simple sampler for the horseshoe estimator,” IEEE Signal Processing Letters, vol. 23, no. 1, pp. 179–182, 2016.DOI
  31. [32]B. Jasińska, M. Gorgol, M. Wiertel, R. Zaleski et al., “Determination of the 3γ fraction from positron annihilation in mesoporous materials for symmetry violation experiment with J-PET scanner,” Acta Physica Polonica B, vol. 47, p. 453, 2016.DOI
  32. [33]P. Moskal, E. Kubicz, G. Grudziąż et al., “Developing a novel positronium biomarker for cardiac myxoma imaging,” EJNMMI Physics, vol. 10, no. 1, p. 22, 2023.DOI
  33. [34]K. Lange, D. R. Hunter, and I. Yang, “Optimization transfer using surrogate objective functions,” Journal of Computational and Graphical Statistics, vol. 9, no. 1, pp. 1–20, 2000.
  34. [35]A. W. van der Vaart, Asymptotic Statistics. Cambridge, U.K.: Cambridge University Press, 1998.
  35. [36]M. L. Clevenson and J. V. Zidek, “Simultaneous estimation of the means of independent Poisson laws,” Journal of the American Statistical Association, vol. 70, no. 351, pp. 698–705, 1975.DOI
  36. [37]A. Ore and J. L. Powell, “Three-photon annihilation of an electron-positron pair,” Physical Review, vol. 75, pp. 1696–1699, 1949.
  37. [38]M. Fujimoto, R. Sato, K. Nakamura et al., “In vivo positronium ratio imaging via direct localization of o-Ps three-photon annihilation,” Talk, Jagiellonian Symposium, July, 2026, list-mode data provided by the authors.
  38. [39]S. K. Lam, A. Pitrou, and S. Seibert, “Numba: a LLVM-based Python JIT compiler,” in Proceedings of the Second Workshop on the LLVM Compiler Infrastructure in HPC, 2015, pp. 1–6.DOI
  39. [40]R. Varadhan and C. Roland, “Simple and globally convergent methods for accelerating the convergence of any EM algorithm,” Scandinavian Journal of Statistics, vol. 35, no. 2, pp. 335–353, 2008.DOI

Paper details

vlnc:W_uayarpnx
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 0

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Mathematics

Not recorded for this paper

View statement
Looking for related papers…
Contents