WorksComputer Science
Learning Neurovascular Codes for EEG-to-fMRI Synthesis
Abstract
In this paper, we introduce Neurovascular Codes as shared EEG representations for fMRI generation. We first train a separate EEG encoder to predict each fMRI signal, learning target-specific temporal and spectral features from the same EEG window. After training, we freeze the encoders and project their concatenated hidden features into a shared neurovascular code. Conditioned on this code, stochastic interpolant transforms Gaussian noise into a vector of fMRI signals, allowing different responses to be sampled for the same EEG window. We evaluate our approach on eight public simultaneous EEG-fMRI datasets, including four resting-state and four task-based datasets with 61,646 volume-level pairs. Under within-subject and held-out-subject evaluation, our model improves average Pearson correlation over the strongest encoder baselines by 19.1% and 19.8%, respectively. The corresponding improvements over the strongest generator baselines are 18.8% and 47.9%. Beyond reconstruction accuracy, we also evaluate the generated signals using subject-identification classifiers trained on real fMRI. Our method achieves the highest mean accuracy among the evaluated generators. We hope that our work opens up new opportunities for cross-modal brain modeling.
Introduction
Learning representations that transfer across tasks is a central aim of foundation models [8]. This approach has been extended to brain signals, including electroencephalography (EEG) and functional magnetic resonance imaging (fMRI). EEG models [40, 35, 89, 64] learn across participants and recording settings. BrainLM [12] learns spatiotemporal fMRI patterns for clinical prediction. Unlike studies that train on one modality alone, we use fMRI prediction to supervise EEG representations for generation.
EEG captures rapid electrical fluctuations in the brain and supports brain-computer interfaces [56, 54]. fMRI measures blood-oxygen-level-dependent (BOLD) signals [63, 52] and maps brain regions and networks [74, 27]. Simultaneous EEG-fMRI recordings [33, 60, 9] pair these complementary measurements.
Figure 1. EEG-to-fMRI synthesis on held-out subjects. Target-level Pearson correlation for NVCode and representative baselines, averaged equally across eight datasets.
Paired EEG-fMRI requires specialized hardware [3] and artifact suppression [61, 33, 9], limiting scale. We build on EEG prediction of individual fMRI signals [41, 46 b] to learn fMRI synthesis from EEG without a concurrent scan.
In this paper, we introduce Neurovascular Codes, termed NVCode, for EEG-to-fMRI synthesis. We first train a separate EEG encoder to predict each fMRI signal from the same EEG window. Through these prediction tasks, the encoders learn target-specific spatiotemporal [87, 24] and spectral [72, 5] features. After training, we discard the prediction heads and freeze the encoders, retaining their hidden features for generation. A learned projection maps the concatenated features into a shared neurovascular code that conditions a stochastic fMRI generator.
An EEG window may correspond to more than one plausible fMRI response (Figure 2). Scalp EEG has spatial ambiguity [33], and neurovascular coupling varies across regions and individuals [52]. We therefore condition a stochastic interpolant on the neurovascular code, using conditional velocity matching [50, 85]. The model learns a velocity field that transforms Gaussian noise into a vector of fMRI signals. Each velocity prediction depends on the current values of all target signals, allowing the field to model dependencies among them. Different noise samples yield different response vectors for the same EEG window. Averaging these samples gives a predictive mean for each fMRI target. The individual draws retain the joint variation across targets, which is not visible in the mean alone.
Figure 2. One-to-many EEG conditioning. For a fixed EEG window, different draws from the Gaussian source can produce distinct joint fMRI responses under the same code.
We evaluate our approach on eight public simultaneous EEG-fMRI datasets, including four resting-state and four task-based datasets with 61,646 volume-level pairs. The benchmark uses common target definitions, data splits, and evaluation metrics. We compare EEG encoders using a common generator architecture and compare generation networks using identical cached EEG codes. We also ablate which target-specific representations are supplied to the generator. Under within-subject and held-out-subject evaluation, our method achieves relative gains in average Pearson correlation of 19.1% and 19.8% over the strongest encoder baselines, respectively. The corresponding gains over the strongest generator baselines are 18.8% and 47.9%.
Beyond prediction accuracy, we evaluate marginal predictive distributions and functional connectivity computed from predictive-mean time series. Our method achieves the lowest average functional connectivity error in both comparisons and evaluation settings. With classifiers trained on real fMRI and held fixed, our generated signals also achieve the highest mean subject-identification accuracy, exceeding accuracy on real fMRI test signals by 3.1 percentage points on average. Our contributions are as follows:
We introduce Neurovascular Codes, shared EEG representations learned through target-specific fMRI prediction and used to condition stochastic fMRI generation.
We establish a benchmark across eight public simultaneous EEG-fMRI datasets, covering four resting-state and four task-based datasets. It uses common target definitions, data splits, and evaluation metrics for comparisons in both within-subject and held-out-subject settings.
We compare EEG encoders, conditional generators, and target-specific representation sets under controlled experimental settings. Beyond reconstruction accuracy, we evaluate the marginal predictive distributions and functional connectivity computed from predictive-mean time series. We assess subject identification performance using classifiers trained on real fMRI signals.
Related Work
EEG and fMRI representation learning. Representation learning is widely used in brain–computer interfaces [56, 54]. Large-scale pretraining provides one way to learn features that transfer across tasks [8]. For EEG, BENDR [40] uses masked contrastive learning, while BIOT [91] enables pretraining across heterogeneous biosignal recordings. LaBraM [35] predicts masked neural tokens, EEGPT [89] pairs masked reconstruction with representation alignment, and REVE [64] uses masked autoencoding with electrode-coordinate embeddings. This line of work addresses variation in electrode layouts [91, 64] and supports a range of EEG decoding tasks [54, 89]. For fMRI, BrainLM [12] learns spatial and temporal structure through masked prediction and supports clinical prediction [12]. During pretraining, these methods construct learning targets from the input signals themselves. Our work instead uses fMRI prediction to supervise EEG representation learning.
EEG-to-fMRI modeling. EEG–fMRI studies relate electrophysiological activity to the BOLD response [63, 52] to investigate neurovascular coupling [52, 60] and constrain EEG source localization [33]. fMRI also supports the study of functional networks [7, 86] through statistical dependencies across brain regions [7, 26]. BEIRA [41] learns interpretable mappings from EEG to BOLD signals, while SIREN-based prediction [46] uses sinusoidal networks to extract frequency information. NeuroBOLT [47] learns spatiotemporal and multiscale spectral features and evaluates prediction on both resting-state and task recordings. UnEBOLT [48] predicts BOLD time series across brain parcels with a single adaptive decoder and estimates functional connectivity from those predictions. NVCode uses target-specific prediction to learn EEG features that condition stochastic generation of the fMRI signal vector.
Conditional generative models. EEG-to-fMRI ambiguity and variable neurovascular coupling motivate probabilistic modeling [52, 60]. Models use stochastic latents [39, 76], adversarial training [58, 34], diffusion denoising [32, 78, 37], or cross-time consistency for few-step sampling [79, 93]. Neural ODEs and FFJORD formulate continuous normalizing flows [14, 30], whereas flow matching, rectified flow, and optimal-transport conditional flow matching learn path velocities [50, 51, 85]. Stochastic interpolants connect distributions through deterministic or stochastic dynamics [2]. NVCode conditions this framework on neurovascular codes and the full fMRI state, allowing interactions among targets.
Neurovascular Codes
NVCode learns EEG representations through individual fMRI prediction tasks and uses these representations to condition fMRI generation. We first train a separate EEG encoder for each fMRI target (§ 3.2). With the encoders frozen, we then train a projector and a conditional velocity field together (§ 3.3 and § 3.4). The projector maps the encoder features to a neurovascular code, which guides generation from Gaussian noise to a vector of fMRI signals. Appendix C provides architectural specifications, derivations, and training and sampling details.
Preliminaries
Each observation pairs the 16 s EEG window immediately preceding an fMRI volume with its BOLD target vector . Here, and count EEG channels and time samples. The vector contains six DiFuMo region-of-interest (ROI) signals [18] and one global signal ().
Projecting the target-specific EEG encoders’ hidden features yields the neurovascular code (§ 3.3). It conditions , with projector parameters and generator parameters . Each generated vector contains seven signals at one acquisition time point. Applying the model to successive EEG windows yields time series for evaluation. Let denote the per-target mean and standard deviation estimated only from the training split. The standardized generation endpoint is
where denotes elementwise division. Standardizing each coordinate separately puts the regional and global signals on a common scale for velocity regression. The same training statistics are used in all splits, including testing on held-out subjects. Inverting the transformation puts generated and observed BOLD vectors on the same fMRI target scale for evaluation.
Learning Target-Specific EEG Representations
Each EEG encoder extracts spatiotemporal and multiscale spectral features to predict one fMRI target from the same window. For target , we attach a linear prediction head to the encoder features and minimize the squared difference between its prediction and the corresponding fMRI target:
Here, is the training set and the feature dimension. Encoder–head pairs are fitted independently and selected by validation mean squared error (MSE). We discard the temporary heads and freeze the selected encoders, retaining their hidden features for code construction.
Constructing Neurovascular Codes
NVCode concatenates the frozen encoder outputs and applies a learned projector . Its first-layer weight matrix is partitioned by encoder output. We write the concatenation, the code, and the first-layer map as:
Here, denotes concatenation, and linearly transforms target features. The projector uses two linear layers with layer normalization [4]. With target-supervised encoders frozen, generation jointly trains the projector and velocity field (§ 3.4). For each EEG window, the same code conditions all targets at every step of sampling.
Learning the Conditional Velocity Field
For each training pair , we compute the neurovascular code and the normalized target from Eq. (1). We draw and independently of the observation and each other. A linear interpolant connects the Gaussian source and normalized fMRI target, with its path velocity given by [50, 85, 2]:
Here, is interpolation time, not recording time. The state and its velocity target are computed directly from the endpoints, without integrating an ODE during training.
We project the full state through a learned linear map and concatenate it with the code and time embedding . A multilayer perceptron (MLP) then maps the concatenated features to one velocity for each fMRI target:
The parameters include the state projection and the MLP. With the code and time fixed, is the Jacobian of the MLP output with respect to . The resulting state Jacobian need not be diagonal, allowing the velocity of each target to depend on other entries in .
We train the projector and velocity field by minimizing
The expectation averages over training pairs, Gaussian source samples, and interpolation times. The loss sums squared velocity errors across all fMRI targets and jointly updates the projector and velocity field parameters. The EEG encoder parameters remain fixed while the projector and conditional velocity field are fitted.
Training. We fit each EEG encoder and its linear head independently with AdamW ([53]). The pair minimizes prediction error for its assigned fMRI target:
Validation MSE selects each encoder checkpoint . With these encoders fixed, the second stage optimizes
We use AdamW with OneCycle scheduling and resample independently for every training example. The projector and velocity field are selected together, giving . Algorithm 1 summarizes the two stages.
Algorithm 1 NVCode fitting
Input: Training data ; validation data ; targets. Output: Frozen encoders ; projector ; field ; statistics .
Estimate on training targets.
Representation fitting
for do
Fit and its head with Eq. (2); select by validation MSE.
Freeze and discard its head.
end for
Initialize , .
Interpolant fitting
repeat
Draw a training batch; compute , and draw independently per example.
Form ; update on .
until the split-specific training schedule ends
Restore the selected projector–field checkpoint.
Generating fMRI Signals
For an unseen EEG window , we compute once from the frozen encoder features. This shared condition remains fixed for all generated samples. We draw independent Gaussian initial states and integrate each trajectory through the learned velocity field from to :
Although the training paths in Eq. (4) are linear, the trajectories induced by the learned field need not be. The sampled states evolve in the same standardized coordinates as the training targets. We draw a new initial state for each trajectory while keeping the learned field and its EEG condition fixed. These trajectories generate alternative samples at one fMRI acquisition time, not successive points in the fMRI time series.
With forward Euler steps of size , the endpoint is . We restore the fMRI target scale and average the samples to estimate the predictive mean:
Here, denotes elementwise multiplication. Increasing reduces the Monte Carlo variability of the estimated mean, not the spread of the generated response distribution.
Algorithm 2 NVCode sampling
Input: EEG window ; frozen , , ; statistics ; steps ; samples .
Output: Samples and predictive mean .
Compute once.
for do
Draw independently.
for do
.
end for
.
end for
Compute .
return .
Algorithm 2 returns samples and their predictive mean. Across aligned EEG windows, these form a sample tensor and an predictive-mean time series. Pearson correlation and functional connectivity mean absolute error (FC-MAE) evaluate the time series; the continuous ranked probability score (CRPS) evaluates marginal sample distributions separately for each fMRI target.
Experiments
We evaluate NVCode on eight public simultaneous EEG-fMRI datasets (Table 1) under within-subject and held-out-subject protocols. § 4.1 compares EEG encoders and conditional generators under matched pipelines; § 4.2 examines temporal and spectral fidelity in representative scans; § 4.3 tests whether generated fMRI retains identity information accessible to a classifier trained only on real data; and § 4.4 examines the effects of the main model components. See Appendix § 7 for dataset-level results and scan examples, and Appendix § 8 for details of the experimental protocols and metrics.
| Type | Dataset | EEG Rate (Hz) | EEG Channels | fMRI TR (s) | fMRI Pairs | Paired Acquisition Duration (s) | Paired Acquisition Scans | Paired Acquisition Cohort Size | Paradigm |
| Rest | Sleep EEG–fMRI (Gu et al., [31]) | 5000 | 32 | 2.1 | 5,714 | 600 | 20 | 33 | Sleep stage |
| Rest | MULTI-CLARID (Stadler et al., [81]) | 5000 | 64 | 2.0 | 10,200 | 600 | 34 | 24 | Eyes open rest |
| Rest | gradCPT (Cha et al., [13]) | 5000 | 64 | 2.0 | 5,040 | 360 | 28 | 28 | Rest subset |
| Rest | NeuroBOLT (Li et al., [47]) | 5000 | 26 | 2.1 | 16,571 | 1200 | 29 | 22 | Multi session rest |
| Active | XP1 (Lioi et al., [49]) | 5000 | 64 | 2.0 | 2,400 | 480 | 10 | 10 | Motor imagery feedback |
| Active | Affective Music (Daly et al., [19]) | 5000 | 31 | 2.0 | 6,300 | 600 | 21 | 21 | Classical music listening |
| Active | Experience Sampling (Kucyi et al., [42]) | 5000 | 64 | 2.0 | 14,850 | 660 | 45 | 24 | Sustained attention task |
| Active | NatView (Telesford et al., [84]) | 5000 | 61 | 2.1 | 571 | 600 | 2 | 22 | Naturalistic film viewing |
Table 1. Eight simultaneous EEG–fMRI datasets span resting-state and task-evoked settings. The source cohorts report 184 participants; after scan-level exclusions, 189 retained scans yield 61,646 paired volumes. Labels follow the source dataset titles, and citations include repository accessions where available.
Main Experiment
Accuracy. We first evaluate reconstruction for participants represented during training (Intra). NVCode achieves the highest average Pearson correlation, 0.480, in both component comparisons. With the same generator architecture fitted separately for each encoder, NVCode exceeds SIREN-based, the best encoder baseline (0.403), by 19.1% (Table 2). With identical cached EEG codes, it exceeds CVAE, the best generation baseline (0.404), by 18.8% (Table 3).
| Encoder | Intra-Subject Avg. ↑ | Intra-Subject CRPS↓ | Intra-Subject FC-MAE↓ | Inter-Subject Avg. ↑ | Inter-Subject CRPS↓ | Inter-Subject FC-MAE↓ |
| BEIRA ([41]) | 0.346 | 0.393 | 0.327 | 0.158 | 0.369 | 0.204 |
| BIOT ([91]) | 0.262 | 0.363 | 0.328 | 0.246 | 0.348 | 0.172 |
| BrainOmni ([90]) | 0.277 | 0.360 | 0.331 | 0.274 | 0.347 | 0.168 |
| CNN-Trans. ([67]) | 0.320 | 0.363 | 0.332 | 0.250 | 0.347 | 0.190 |
| ContraWR ([92]) | 0.329 | 0.390 | 0.348 | 0.238 | 0.358 | 0.221 |
| FFCL ([45]) | 0.315 | 0.389 | 0.351 | 0.264 | 0.363 | 0.197 |
| LaBraM ([35]) | 0.265 | 0.360 | 0.319 | 0.304 | 0.345 | 0.187 |
| SIREN-based ([46]) | 0.403 | 0.383 | 0.315 | 0.301 | 0.354 | 0.189 |
| REVE ([64]) | 0.220 | 0.365 | 0.340 | 0.174 | 0.351 | 0.200 |
| SPaRCNet ([36]) | 0.330 | 0.379 | 0.330 | 0.353 | 0.344 | 0.163 |
| STT-Trans. ([80]) | 0.258 | 0.381 | 0.323 | 0.192 | 0.362 | 0.163 |
| NVCode (Ours) | 0.480 | 0.352 | 0.280 | 0.423 | 0.344 | 0.135 |
Table 2. EEG encoder comparison. We fit the same generator architecture separately for each frozen encoder. Higher Avg. (mean Pearson correlation) and lower marginal CRPS and predictive-mean FC-MAE are better. Best values are darker purple, bold; second best values are light purple, underlined.
| Generator | Intra-Subject Avg. ↑ | Intra-Subject CRPS↓ | Intra-Subject FC-MAE↓ | Inter-Subject Avg. ↑ | Inter-Subject CRPS↓ | Inter-Subject FC-MAE↓ |
| cGAN (Mirza and Osindero, [58]) | 0.310 | 0.462 | 0.505 | 0.211 | 0.368 | 0.297 |
| Consistency (Yang et al., [93]) | 0.328 | 0.452 | 0.357 | 0.283 | 0.431 | 0.240 |
| CVAE (Sohn et al., [76]) | 0.404 | 0.378 | 0.336 | 0.280 | 0.345 | 0.244 |
| DDPM (Ho et al., [32]) | 0.302 | 0.358 | 0.309 | 0.197 | 0.346 | 0.170 |
| EDM (Karras et al., [37]) | 0.351 | 0.361 | 0.323 | 0.286 | 0.343 | 0.211 |
| Rectified Flow (Liu et al., [51]) | 0.302 | 0.364 | 0.328 | 0.234 | 0.350 | 0.242 |
| Score SDE (Song et al., [78]) | 0.343 | 0.361 | 0.346 | 0.280 | 0.339 | 0.202 |
| NVCode (Ours) | 0.480 | 0.352 | 0.280 | 0.423 | 0.344 | 0.135 |
Table 3. Conditional generator comparison. All networks use the same cached EEG codes from seven frozen encoders and the frozen NVCode projector. Each evaluation weights all eight datasets equally.
NVCode retains its correlation advantage when evaluated on unseen participants. Under Inter evaluation, it reaches across eight equally weighted datasets. This is 19.8% higher than SPaRCNet (0.353) in the encoder comparison (Table 2) and 47.9% higher than EDM (0.286) with identical cached EEG codes (Table 3). The larger generator gap in Inter makes it especially useful to separate the two controls: one changes which EEG features reach the generator, and the other changes how the generator uses a fixed input. Both controls evaluate new participants within each dataset’s acquisition setting.
Encoder comparison. We vary the EEG representation while keeping the generator architecture fixed. On held-out participants, NVCode improves on SPaRCNet in six of seven targets (Figure 4a). The largest gain is in the global signal, from 0.324 to 0.487; both subcortical targets also improve. The per-target results in Table 10 show how these gains contribute to the average across targets.
Figure 4. EEG encoders on held-out subjects. (a) Pearson for middle frontal gyrus, cuneus, thalamus, putamen, Heschl’s gyrus, precuneus, and global signal, in axis order. (b) One minus each mean error (CRPS and FC-MAE) from the Inter columns of Table 2. Higher bars correspond to smaller marginal and connectivity errors.
| Encoder | Cuneus | Heschl’s Gyrus | Middle Frontal | Precuneus | Putamen | Thalamus | Avg. ↑ | CRPS↓ | FC-MAE↓ | |
| Intra subject BEIRA | 0.302 | 0.372 | 0.257 | 0.372 | 0.384 | 0.344 | 0.392 | 0.346 | 0.393 | 0.327 |
| BIOT | 0.275 | 0.218 | 0.299 | 0.239 | 0.280 | 0.245 | 0.278 | 0.262 | 0.363 | 0.328 |
| BrainOmni | 0.240 | 0.386 | 0.297 | 0.308 | 0.258 | 0.256 | 0.196 | 0.277 | 0.360 | 0.331 |
| CNN-Trans. | 0.247 | 0.415 | 0.264 | 0.309 | 0.362 | 0.314 | 0.332 | 0.320 | 0.363 | 0.332 |
| ContraWR | 0.311 | 0.370 | 0.351 | 0.314 | 0.334 | 0.264 | 0.356 | 0.329 | 0.390 | 0.348 |
| FFCL | 0.342 | 0.264 | 0.361 | 0.288 | 0.378 | 0.292 | 0.278 | 0.315 | 0.389 | 0.351 |
| LaBraM | 0.280 | 0.201 | 0.280 | 0.282 | 0.303 | 0.278 | 0.231 | 0.265 | 0.360 | 0.319 |
| SIREN-based | 0.443 | 0.406 | 0.407 | 0.321 | 0.438 | 0.404 | 0.400 | 0.403 | 0.383 | 0.315 |
| REVE | 0.116 | 0.302 | 0.214 | 0.239 | 0.242 | 0.155 | 0.271 | 0.220 | 0.365 | 0.340 |
| SPaRCNet | 0.334 | 0.341 | 0.243 | 0.257 | 0.359 | 0.367 | 0.410 | 0.330 | 0.379 | 0.330 |
| STT-Trans. | 0.276 | 0.296 | 0.268 | 0.257 | 0.227 | 0.269 | 0.216 | 0.258 | 0.381 | 0.323 |
| NVCode (Ours) | 0.449 | 0.503 | 0.400 | 0.506 | 0.500 | 0.477 | 0.524 | 0.480 | 0.352 | 0.280 |
| Inter subject BEIRA | 0.250 | 0.180 | 0.128 | 0.177 | 0.118 | 0.102 | 0.148 | 0.158 | 0.369 | 0.204 |
| BIOT | 0.232 | 0.204 | 0.215 | 0.324 | 0.231 | 0.281 | 0.236 | 0.246 | 0.348 | 0.172 |
| BrainOmni | 0.216 | 0.304 | 0.257 | 0.308 | 0.316 | 0.293 | 0.227 | 0.274 | 0.347 | 0.168 |
| CNN-Trans. | 0.309 | 0.299 | 0.186 | 0.242 | 0.334 | 0.235 | 0.144 | 0.250 | 0.347 | 0.190 |
| ContraWR | 0.192 | 0.128 | 0.355 | 0.333 | 0.240 | 0.230 | 0.189 | 0.238 | 0.358 | 0.221 |
| FFCL | 0.287 | 0.250 | 0.320 | 0.293 | 0.203 | 0.267 | 0.225 | 0.264 | 0.363 | 0.197 |
| LaBraM | 0.304 | 0.346 | 0.289 | 0.332 | 0.290 | 0.286 | 0.280 | 0.304 | 0.345 | 0.187 |
| SIREN-based | 0.346 | 0.347 | 0.215 | 0.338 | 0.266 | 0.307 | 0.289 | 0.301 | 0.354 | 0.189 |
| REVE | 0.218 | 0.203 | 0.162 | 0.177 | 0.165 | 0.110 | 0.182 | 0.174 | 0.351 | 0.200 |
| SPaRCNet | 0.397 | 0.362 | 0.365 | 0.190 | 0.370 | 0.345 | 0.324 | 0.353 | 0.344 | 0.163 |
| STT-Trans. | 0.209 | 0.195 | 0.241 | 0.141 | 0.198 | 0.199 | 0.158 | 0.192 | 0.362 | 0.163 |
| NVCode (Ours) | 0.392 | 0.475 | 0.434 | 0.370 | 0.405 | 0.396 | 0.487 | 0.423 | 0.344 | 0.135 |
Table 10. EEG-to-fMRI synthesis by encoder and generator. Signal columns report Pearson for each target. Avg. , CRPS, and FC-MAE summarize performance across the eight datasets. Ranking applies within each split and comparison. Best values are darker purple, bold; second-best values are light purple, underlined.
The encoder change also improves predictive-mean connectivity. Relative to SPaRCNet, FC-MAE falls from 0.163 to 0.135, a 17.2% reduction, while marginal CRPS stays at 0.344 to the reported precision (Figure 4b). Thus, at fixed generator architecture, gains in how the signals vary together can occur with little change in the marginal scores for the individual targets.
Generator comparison. We next hold the conditioning input fixed and vary the generator. All baselines in Table 3 receive the same cached codes from the NVCode projector, so differences arise after the EEG representation has already been formed. The leading alternative in Avg. changes from CVAE in Intra to EDM in Inter, whereas NVCode retains the highest correlation under both protocols. Figure 5a shows that this advantage extends across all seven signals relative to DDPM and CVAE on held-out participants. Heschl’s gyrus, for example, reaches 0.475 versus 0.309 for CVAE, and the thalamus reaches 0.396 versus 0.294. The gains therefore span cortical and subcortical targets as well as the global time series.
Figure 5. Generators on held-out subjects. (a) Pearson for NVCode, DDPM, and CVAE given the same cached EEG codes. Targets follow Figure 4. (b) One minus each mean error (CRPS and FC-MAE) from Table 3, so higher bars indicate lower error. The eight datasets receive equal weight in each held-out-subject summary.
The benchmark gives each dataset the same weight regardless of its number of scans. Tables 12a–12h separate the dataset means and show seed variation where reported. This breakdown distinguishes the benchmark average from performance on any one dataset.
With those same cached inputs, NVCode attains the lowest FC-MAE, reducing the Inter error by 20.6% relative to DDPM. In Figure 5b, its marginal CRPS is also lower than those of DDPM and CVAE, although Score SDE leads on that metric in Table 3. These tests separate two uses of a conditional generator: tracking each recorded trajectory and recovering the correlations across the predictive means. NVCode improves both under the same held-out evaluation and fixed EEG code used for the generator comparison.
Pooled training. Can a single model preserve the reconstruction advantage across acquisition settings and tasks? Table 4 replaces separate dataset fits with a common training pool drawn from all eight datasets. The Inter protocol still holds out participants rather than entire datasets, so this comparison tests generalization to new participants within a common multi-dataset training setup. The seven prediction targets stay the same when training examples come from multiple corpora. NVCode leads on Avg. , CRPS, and FC-MAE under both splits. Relative to UnEBOLT, Avg. rises from 0.475 to 0.500 in Intra and from 0.403 to 0.431 in Inter. The Inter gains extend to the output distributions and their average trajectories: CRPS decreases from 0.384 to 0.316, and FC-MAE from 0.262 to 0.172. The pooled model also attains the highest correlation in five of seven signals in either split. On held-out participants, this roughly one-third reduction in FC-MAE accompanies gains in the individual time courses. The benefit thus spans several targets and persists under pooled training. The next control returns to fixed encoder features and gives each generator a separate conditioning map on the same held-out participants.
Table 4. End-to-end comparison. All methods train on the same pool of eight EEG–fMRI datasets. The scores use matched Intra and Inter splits for all three methods.
Generator-specific projectors. We fit DDPM, EDM and Score SDE with separate projectors of dimension 512, retaining the same frozen EEG features (Table 5). This changes the conditioning map but keeps its input and the set of participants used for held-out evaluation fixed.
| Generator | Projector | Avg. ↑ | CRPS↓ | FC-MAE↓ |
| DDPM | Frozen | 0.197 | 0.346 | 0.170 |
| Own | 0.172 | 0.319 | 0.195 | |
| EDM | Frozen | 0.286 | 0.343 | 0.211 |
| Own | 0.299 | 0.381 | 0.207 | |
| Score SDE | Frozen | 0.280 | 0.339 | 0.202 |
| Own | 0.249 | 0.310 | 0.246 | |
| NVCode | Own | 0.423 | 0.344 | 0.135 |
Table 5. Generator-specific projectors. Frozen uses the cached codes; Own jointly fits the projector and generator. Held-out scores give all eight datasets equal weight.
NVCode retains the highest Avg. (0.423) and lowest FC-MAE (0.135) when the alternatives adapt their own projectors. Score SDE leads on marginal CRPS (0.310), so the best generator depends on which property the metric tests. Appendix § 8.§ 2 gives the two training protocols.
The three baselines kept their correlation ranking, but the error metrics responded differently. EDM’s Avg. increased from 0.286 to 0.299 while marginal CRPS rose from 0.343 to 0.381. DDPM and Score SDE instead reduced CRPS at lower correlation. Thus a learned conditioning map can improve one aspect of synthesis without improving another. Across these projector settings, the same NVCode configuration led in temporal correlation and connectivity, while the best marginal score came from Score SDE. The fixed-projector result therefore establishes a common comparison point, and the adaptive comparison shows which advantages persist when baselines can change their conditioning map.
Analysis
Temporal fidelity. Figure 6 compares two reconstructions of the same Cuneus signal. Both models receive the same EEG, as reflected by the identical spectrograms and alpha scalp maps. NVCode recovers local reversals and the late positive excursion more closely than EDM, giving rather than 0.501. Correlation measures agreement over the whole segment; the marked time point tests whether that agreement also translates into an accurate amplitude estimate at one time point in the recorded Cuneus signal.
Figure 6. Matched EEG–fMRI evidence for Cuneus. (a, b): Identical EEG inputs in both rows. (c): Real fMRI (black dashed), NVCode (top, red), and EDM (bottom, grey), with correlations. (d): Real, predicted, and absolute-error amplitudes projected onto Cuneus at 54.6 s (purple guides) with a shared color scale.
At 54.6 s, NVCode predicts 0.593 and EDM predicts 0.224 against a measured value of 0.703. The absolute error drops from 0.479 to 0.110 (77.0%). Panel (d) uses the same anatomical weights and color scale for both models to visualize regional amplitude errors at that instant. The shared geometry isolates differences in predicted amplitude from differences in anatomical support.
Spectral fidelity. We next inspect how power is distributed across frequencies in the global signal. Resting BOLD activity is concentrated at low frequencies ([25, 16]). We examine the scan selected for closest alignment with the recorded global signal. NVCode approaches the measured peak and tracks the decay of power (Figure 7), while EDM places its peak at a higher frequency than the peak of the recorded global fMRI signal.
Figure 7. Global signal spectra. Power on log axes for real fMRI and the NVCode and EDM predictive means.
The peak locates the dominant timescale, while the descending branch describes the attenuation of faster fluctuations. These readings complement Figure 6 by describing global power across frequencies rather than local amplitudes over time.
Downstream Utility
Testing on synthetic fMRI. We test whether EEG-conditioned fMRI preserves features that a classifier trained on measured fMRI can use to identify participants. For each dataset, we fit the classifier on real fMRI and keep it fixed for both evaluations. We then replace the held-out real test inputs with predictions from matched EEG epochs while keeping the identity labels and test segments the same. The real-input row in Table 6 establishes the reference for each dataset; the remaining rows report accuracy differences relative to that reference. Because the classifier has never seen synthetic fMRI, it cannot adapt its decision rule to the output of any particular generator. The comparison tests transfer across input types within a dataset, using the same participant label set for every generator.
Table 6 Synthetic fMRI transfers to a classifier trained only on real fMRI. The first row gives real input accuracy; synthetic rows report the change using predictions from matched EEG epochs. Classifier parameters stay fixed, and Mean weights all eight datasets equally in both the real and synthetic test conditions.
| Method | Sleep EEG–fMRI | MULTI-CLARID | gradCPT | NeuroBOLT | XP1 | Affective Music | NatView | Experience Sampling | Mean |
| Real test | 0.861 | 0.787 | 0.746 | 0.869 | 0.874 | 0.782 | 0.747 | 0.702 | 0.796 |
| cGAN (Mirza and Osindero, [58]) | +0.022 | +0.018 | +0.013 | +0.014 | +0.008 | +0.019 | +0.027 | +0.002 | +0.015 |
| Consistency (Yang et al., [93]) | +0.017 | +0.024 | +0.026 | +0.019 | +0.010 | +0.011 | +0.021 | +0.014 | +0.018 |
| CVAE (Sohn et al., [76]) | +0.011 | +0.016 | +0.034 | +0.037 | +0.017 | +0.005 | +0.033 | +0.012 | +0.021 |
| DDPM (Ho et al., [32]) | +0.026 | +0.019 | +0.020 | +0.035 | +0.024 | +0.023 | +0.032 | +0.014 | +0.024 |
| EDM (Karras et al., [37]) | +0.007 | +0.021 | +0.026 | +0.022 | +0.009 | +0.025 | +0.038 | +0.008 | +0.020 |
| Rectified Flow (Liu et al., [51]) | +0.015 | +0.008 | +0.018 | +0.032 | +0.012 | +0.010 | +0.041 | +0.011 | +0.018 |
| Score SDE (Song et al., [78]) | +0.021 | +0.016 | +0.027 | +0.029 | +0.015 | +0.006 | +0.026 | +0.015 | +0.019 |
| NVCode (Ours) | +0.028 | +0.027 | +0.036 | +0.043 | +0.019 | +0.031 | +0.045 | +0.020 | +0.031 |
Table 6.
NVCode produces the largest mean gain, 3.1 percentage points versus 2.4 for DDPM, and ranks first on seven of the eight datasets. On XP1, DDPM gains 2.4 points versus 1.9 for NVCode. The average gives each dataset equal weight, so the lead reflects gains across acquisition settings rather than the contribution of the largest test set. The table also separates the difficulty of identification on real fMRI from the benefit of replacing those test inputs. For example, NVCode gains 4.3 points on NeuroBOLT and 4.5 on NatView, although real-input accuracy differs substantially between the two datasets (86.9% and 74.7%).
All generators raise mean accuracy in this protocol. EEG-conditioned estimates may retain stable features that the classifier uses while attenuating variation in the measured signals that matters less for identity. The experiment measures how readily a fixed classifier can identify participants, whereas the reconstruction analyses measure agreement with the recorded signals. Appendix B.3 reports the reverse test: classifiers train on synthetic fMRI and are tested on the same held-out real fMRI epochs (Table 14).
| Dataset | DDPM | NVCode |
| Sleep EEG–fMRI | +0.014 | +0.007 |
| MULTI-CLARID | +0.009 | +0.015 |
| gradCPT | +0.023 | +0.021 |
| NeuroBOLT | −0.005 | +0.008 |
| XP1 | −0.003 | +0.016 |
| Affective Music | +0.010 | +0.014 |
| NatView | −0.014 | +0.019 |
| Experience Sampling | +0.009 | +0.010 |
| Mean | +0.005 | +0.014 |
Table 14. Synthetic training, real fMRI tests. Each entry is the change from real fMRI training on the same test epochs. Mean weights all eight datasets equally.
Ablation Study
Joint sample quality. We shuffle draws by target within each EEG window, preserving the marginal samples and means. Energy score (ES) evaluates the full vector; variogram score (VS) evaluates 21 pairwise contrasts. Original draws reduce ES by 19.3% and VS by 38.3% over shuffling and improve on independent interpolants (Table 8). Joint coverage is 90.39% at a 90% nominal target for the full response vector.
| Variant | ES | VS | 90% Joint Cov. |
| Independent Interpolants | 12.63 | 5.39 | 87.41% |
| NVCode (Shuffled) | 9.36 | 4.72 | 88.36% |
| NVCode | 7.55 | 2.91 | 90.39% |
| Paired | −5.08 | −2.48 | +2.98 pp |
Table 8. Joint sample quality. Scores and joint coverage (90% nominal) on held-out subjects. is NVCode minus Independent Interpolants; pp denotes percentage points.
Predictive-mean FC-MAE uses sequences of means across EEG windows, while joint scores evaluate how targets are paired within a draw. Shuffling preserves the means and thus leaves FC-MAE unchanged. The lower multivariate errors for the original draws reflect the original pairing rather than differences in marginals. Joint coverage requires the full seven-signal observation to lie in the predicted region, rather than testing each target separately (Appendix § 8.§ 4.3).
Across the four output designs in Table 7, regional encoders improve Avg. and predictive-mean FC-MAE in every comparison, with correlation gains ranging from 0.074 for joint interpolation to 0.129 for independent interpolation. Full NVCode leads on all three scores and gives the largest mean identity gain against single-signal representations (Appendix § 8.§ 4.1). Appendix § 8.§ 2 reports the parameter-matched encoder comparison.
| Variant | Regional Encoders | Joint Output | Stochastic Interpolant | Avg. | CRPS | FC-MAE |
| Deterministic Joint Regression | ✓ | ✓ | × | 0.317 | 0.368 | 0.250 |
| Independent Interpolants | ✓ | × | ✓ | 0.405 | 0.377 | 0.174 |
| NVCode with a Shared Encoder | × | ✓ | ✓ | 0.349 | 0.362 | 0.182 |
| First-Stage Linear Heads | ✓ | × | × | 0.241 | 0.430 | 0.213 |
| Shared Independent Interpolants | × | × | ✓ | 0.276 | 0.392 | 0.266 |
| Shared Joint Regression | × | ✓ | × | 0.205 | 0.357 | 0.392 |
| Shared Linear Head | × | × | × | 0.119 | 0.428 | 0.485 |
| NVCode (Ours) | ✓ | ✓ | ✓ | 0.423 | 0.344 | 0.135 |
Table 7. Component ablation on held-out subjects. Eight variants test all combinations of regional encoders, joint output, and stochastic interpolation. ✓ and × indicate whether a component is included or excluded.
▹ Deterministic Joint Regression. We replace joint interpolation with a joint MLP, using the same frozen regional features and jointly training the projector (Appendix § 8.§ 4.2.a). With interpolation, Avg. rises from 0.317 to 0.423, FC-MAE falls from 0.250 to 0.135, and marginal CRPS falls from 0.368 to 0.344. Both designs predict the target vector jointly, so the comparison asks whether learning a conditional distribution improves on a joint point predictor. The gain spans the individual trajectories, their predictive-mean connectivity, and the quality of the predictive distributions for the individual targets.
▹ Independent Interpolants. We test whether the interpolant benefits from the other signals’ evolving states. The seven scalar interpolants use the same regional-feature condition but evolve each target independently (Appendix § 8.§ 4.2.b). With joint state access, Avg. rises from 0.405 to 0.423 and FC-MAE falls from 0.174 to 0.135. This contrast changes how the outputs interact while retaining the same EEG representation.
▹ NVCode with a Shared Encoder. We use one jointly supervised encoder, retaining the 1400-dimensional interface and joint interpolant (Appendix § 8.§ 4.2.c). Regional encoders raise Avg. from 0.349 to 0.423 and lower FC-MAE from 0.182 to 0.135. Separately supervised features thus provide more effective conditioning for this output design. The same ordering also holds for three other predictors: direct linear heads, deterministic joint regression and interpolation with independent scalar fields.
▹ First-Stage Linear Heads. Without a generator, regional heads reach Avg. versus 0.119 for the shared head, and FC-MAE falls from 0.485 to 0.213 (Table 7; Appendix § 8.§ 4.2.d). With the same frozen regional encoders, the joint interpolant raises Avg. to 0.423.
Shared Independent Interpolants. We fit scalar interpolants on frozen shared features, using the shared joint-interpolation encoder (Appendix § 8.§ 4.2.e). Joint state access raises Avg. from 0.276 to 0.349 and lowers FC-MAE from 0.266 to 0.182. Marginal CRPS also decreases from 0.392 to 0.362, extending the improvement from mean trajectories to marginal probabilistic prediction with one encoder. This output-design benefit therefore holds for both regional and shared EEG representations.
Shared Joint Regression. We fit a joint deterministic regressor on the shared encoder features (Appendix § 8.§ 4.2.f). Its marginal CRPS of 0.357 ranks second and equals absolute prediction error for this deterministic control. With the same encoder, joint interpolation raises Avg. from 0.205 to 0.349 and lowers FC-MAE from 0.392 to 0.182. Joint interpolation therefore improves regional trajectories and predictive-mean connectivity; full NVCode achieves the best scores across all three metrics.
Shared Linear Head. We retain the shared encoder’s linear head (Appendix § 8.§ 4.2.g). With identical frozen features, Avg. rises from 0.119 to 0.205 with joint regression, 0.276 with independent interpolation and 0.349 with joint interpolation. Joint interpolation reduces FC-MAE from 0.485 to 0.182. Among the shared variants, joint interpolation attains the highest temporal correlation and lowest connectivity error. Because all four predictors receive the same frozen EEG features, this comparison isolates the effect of changing the output design while retaining the same learned EEG representation.
Conclusion
We presented Neurovascular Codes for EEG-to-fMRI synthesis. NVCode learns target-specific EEG features through individual fMRI prediction tasks and projects them into a shared code for stochastic fMRI generation. Across eight public datasets, it achieves the highest average Pearson correlation and the lowest predictive-mean FC-MAE in both encoder and generator comparisons, under within-subject and held-out-subject evaluation. Ablations favor regional conditioning combined with joint interpolation. Using fixed classifiers trained on real fMRI, NVCode signals from matched EEG epochs achieve the highest mean subject-identification accuracy among the generators evaluated under the same classification protocol.
Discussion. More broadly, our results suggest that learning to predict fMRI can organize EEG representations for conditional signal generation. Reciprocal generation would ask which information is shared between the two modalities. An EEG window could be mapped to a seven-signal fMRI response and then reconstructed from that response, testing which features survive the round trip. A cycle beginning in fMRI could test whether an inferred EEG signal supports recovery of the original response pattern. Comparing each cycle against mismatched windows would distinguish information about the current window from patterns that recur across a scan. Scoring regional trajectories and cross-target structure separately would distinguish features recovered in both directions from features supported by only one mapping. A cross-dataset cycle could test whether these shared features remain recoverable when both mappings are evaluated on a new acquisition setting without refitting. Scores for the two directions could then be reported separately against the same mappings evaluated on matched windows in the original corpus. This would distinguish errors tied to one direction from a loss of shared information when the dataset changes.
Appendix
This appendix presents additional results and documents the experimental and model details.
Appendix § 7 reports results by dataset and illustrates individual scans.
Appendix § 8 describes the evaluation protocols, comparisons, and ablations.
Appendix § 9 gives the derivations, architecture, training, and sampling details.
Additional Results
Main EEG to fMRI Synthesis Results
Table 9 gives the seven target scores for models trained on pooled data. Table 10 summarizes separate fits within each dataset: encoder comparisons hold the generator architecture fixed, and generation-network comparisons use the same cached EEG codes. Tables 11a–11h and 12a–12h give the individual dataset scores underlying the component comparisons. Section B.2 defines the split and dataset averages used in these comparisons.
The target columns show how performance varies within each evaluation split. In the pooled Inter setting, NVCode reaches in the precuneus and in the putamen. These correlations describe agreement over time for individual signals. The lower FC-MAE of 0.172 versus 0.262 for UnEBOLT shows that the pooled results also improve agreement between the predictive-mean and recorded connectivity matrices.
Per Dataset Encoder Results
Seven regional encoders and single-encoder baselines use one generator architecture fitted separately for each configuration. Signal columns report the mean ± standard deviation across seeds 42, 2026, and 114514 in both comparisons. XP1 and NatView retained 10 and 2 scans, respectively (Table 1). With so few scans, the often large standard deviations across seeds offer little basis for comparing methods. We report only the means for these two datasets in both splits. Avg. R, CRPS, and FC-MAE average the same runs. Best values are darker purple, bold; second-best values are light purple, underlined.
| Encoder | Cuneus | Heschl’s Gyrus | Middle Frontal | Precuneus | Putamen | Thalamus | Global Signal | Avg. R↑ | CRPS↓ | FC-MAE↓ |
| BEIRA | 0.311±0.161 | 0.263±0.183 | 0.525±0.186 | 0.372±0.231 | 0.378±0.181 | 0.443±0.175 | 0.302±0.202 | 0.371 | 0.393 | 0.247 |
| BIOT | 0.239±0.109 | 0.318±0.105 | 0.265±0.107 | 0.217±0.111 | 0.301±0.103 | 0.292±0.126 | 0.252±0.116 | 0.269 | 0.342 | 0.276 |
| BrainOmni | 0.276±0.098 | 0.319±0.158 | 0.301±0.110 | 0.307±0.143 | 0.306±0.122 | 0.262±0.114 | 0.260±0.124 | 0.290 | 0.347 | 0.255 |
| CNN-Trans. | 0.351±0.134 | 0.319±0.179 | 0.419±0.177 | 0.387±0.183 | 0.309±0.161 | 0.293±0.126 | 0.336±0.185 | 0.345 | 0.335 | 0.245 |
| ContraWR | 0.351±0.195 | 0.308±0.175 | 0.442±0.187 | 0.297±0.239 | 0.396±0.195 | 0.315±0.207 | 0.392±0.203 | 0.357 | 0.361 | 0.281 |
| FFCL | 0.324±0.200 | 0.418±0.157 | 0.487±0.159 | 0.361±0.221 | 0.487±0.180 | 0.405±0.195 | 0.340±0.193 | 0.403 | 0.367 | 0.290 |
| LaBraM | 0.221±0.114 | 0.181±0.121 | 0.228±0.126 | 0.236±0.112 | 0.282±0.088 | 0.271±0.128 | 0.223±0.127 | 0.235 | 0.344 | 0.280 |
| SIREN-based | 0.268±0.196 | 0.423±0.172 | 0.461±0.133 | 0.475±0.198 | 0.384±0.190 | 0.303±0.159 | 0.368±0.153 | 0.383 | 0.358 | 0.259 |
| REVE | 0.275±0.102 | 0.380±0.119 | 0.233±0.133 | 0.299±0.146 | 0.342±0.155 | 0.334±0.108 | 0.304±0.123 | 0.309 | 0.354 | 0.309 |
| SPaRCNet | 0.384±0.188 | 0.436±0.179 | 0.381±0.173 | 0.459±0.198 | 0.433±0.151 | 0.366±0.160 | 0.353±0.164 | 0.402 | 0.348 | 0.277 |
| STT-Trans. | 0.253±0.121 | 0.414±0.160 | 0.387±0.120 | 0.335±0.111 | 0.296±0.130 | 0.239±0.171 | 0.363±0.145 | 0.327 | 0.348 | 0.262 |
| NVCode (Ours) | 0.366±0.175 | 0.522±0.186 | 0.472±0.143 | 0.524±0.135 | 0.608±0.118 | 0.491±0.131 | 0.534±0.145 | 0.502 | 0.339 | 0.239 |
| BEIRA | 0.140±0.058 | 0.290±0.233 | 0.248±0.125 | 0.405±0.080 | 0.283±0.203 | 0.170±0.068 | 0.248±0.125 | 0.255 | 0.332 | 0.126 |
| BIOT | 0.235±0.073 | 0.320±0.127 | 0.334±0.104 | 0.299±0.185 | 0.324±0.119 | 0.302±0.182 | 0.343±0.092 | 0.308 | 0.331 | 0.100 |
| BrainOmni | 0.201±0.108 | 0.219±0.125 | 0.207±0.113 | 0.272±0.221 | 0.332±0.208 | 0.293±0.209 | 0.064±0.054 | 0.232 | 0.338 | 0.093 |
| CNN-Trans. | 0.212±0.121 | 0.291±0.315 | 0.227±0.137 | 0.183±0.099 | 0.267±0.211 | 0.152±0.082 | 0.185±0.100 | 0.217 | 0.336 | 0.097 |
| ContraWR | 0.153±0.115 | 0.292±0.400 | 0.489±0.094 | 0.543±0.076 | 0.573±0.067 | 0.213±0.170 | 0.677±0.052 | 0.420 | 0.332 | 0.208 |
| FFCL | 0.221±0.204 | 0.191±0.163 | 0.582±0.075 | 0.475±0.113 | 0.395±0.179 | 0.266±0.327 | 0.625±0.058 | 0.394 | 0.336 | 0.098 |
| LaBraM | 0.310±0.300 | 0.452±0.078 | 0.249±0.165 | 0.358±0.152 | 0.492±0.065 | 0.282±0.258 | 0.378±0.127 | 0.360 | 0.333 | 0.129 |
| SIREN-based | 0.328±0.366 | 0.539±0.089 | 0.459±0.125 | 0.529±0.092 | 0.437±0.141 | 0.451±0.131 | 0.401±0.177 | 0.449 | 0.329 | 0.158 |
| REVE | 0.239±0.172 | 0.139±0.086 | 0.228±0.154 | 0.078±0.066 | 0.262±0.223 | 0.180±0.108 | 0.126±0.081 | 0.179 | 0.338 | 0.132 |
| SPaRCNet | 0.250±0.266 | 0.536±0.086 | 0.449±0.126 | 0.362±0.233 | 0.565±0.075 | 0.451±0.153 | 0.394±0.177 | 0.425 | 0.328 | 0.092 |
| STT-Trans. | 0.147±0.133 | 0.151±0.136 | 0.126±0.120 | 0.105±0.110 | 0.027±0.082 | 0.207±0.193 | 0.079±0.098 | 0.120 | 0.347 | 0.107 |
| NVCode (Ours) | 0.194±0.207 | 0.613±0.142 | 0.553±0.178 | 0.410±0.400 | 0.557±0.175 | 0.433±0.362 | 0.430±0.373 | 0.456 | 0.327 | 0.096 |
Table 11a. Encoder comparison on Sleep EEG–fMRI (Resting State).
| Encoder | Cuneus | Heschl’s Gyrus | Middle Frontal | Precuneus | Putamen | Thalamus | Global Signal | Avg. R↑ | CRPS↓ | FC-MAE↓ |
| BEIRA | 0.408±0.127 | 0.466±0.131 | 0.470±0.126 | 0.544±0.112 | 0.523±0.131 | 0.608±0.113 | 0.464±0.114 | 0.498 | 0.442 | 0.316 |
| BIOT | 0.452±0.089 | 0.406±0.096 | 0.360±0.102 | 0.377±0.103 | 0.414±0.106 | 0.377±0.085 | 0.492±0.100 | 0.411 | 0.406 | 0.312 |
| BrainOmni | 0.428±0.087 | 0.441±0.091 | 0.466±0.090 | 0.371±0.086 | 0.418±0.100 | 0.424±0.093 | 0.423±0.096 | 0.424 | 0.395 | 0.308 |
| CNN-Trans. | 0.415±0.126 | 0.472±0.117 | 0.533±0.138 | 0.351±0.082 | 0.552±0.114 | 0.494±0.119 | 0.439±0.115 | 0.465 | 0.421 | 0.346 |
| ContraWR | 0.409±0.102 | 0.428±0.120 | 0.591±0.103 | 0.367±0.109 | 0.540±0.106 | 0.512±0.097 | 0.409±0.094 | 0.465 | 0.437 | 0.335 |
| FFCL | 0.438±0.094 | 0.474±0.110 | 0.460±0.108 | 0.457±0.086 | 0.430±0.113 | 0.468±0.119 | 0.440±0.120 | 0.453 | 0.448 | 0.325 |
| LaBraM | 0.492±0.072 | 0.465±0.108 | 0.432±0.090 | 0.426±0.090 | 0.478±0.113 | 0.478±0.113 | 0.410±0.084 | 0.458 | 0.400 | 0.295 |
| SIREN-based | 0.506±0.099 | 0.478±0.141 | 0.578±0.131 | 0.404±0.113 | 0.651±0.106 | 0.638±0.120 | 0.388±0.108 | 0.520 | 0.424 | 0.310 |
| REVE | 0.330±0.085 | 0.342±0.070 | 0.363±0.068 | 0.337±0.071 | 0.392±0.064 | 0.390±0.076 | 0.395±0.057 | 0.364 | 0.408 | 0.311 |
| SPaRCNet | 0.428±0.096 | 0.424±0.123 | 0.442±0.124 | 0.485±0.109 | 0.608±0.124 | 0.618±0.124 | 0.564±0.105 | 0.510 | 0.426 | 0.344 |
| STT-Trans. | 0.422±0.101 | 0.403±0.109 | 0.396±0.130 | 0.383±0.107 | 0.377±0.105 | 0.234±0.124 | 0.326±0.093 | 0.363 | 0.446 | 0.350 |
| NVCode (Ours) | 0.524±0.100 | 0.484±0.128 | 0.639±0.124 | 0.416±0.096 | 0.606±0.119 | 0.650±0.117 | 0.482±0.124 | 0.543 | 0.384 | 0.276 |
| BEIRA | 0.163±0.053 | 0.421±0.058 | 0.394±0.070 | 0.311±0.183 | 0.468±0.045 | 0.403±0.065 | 0.314±0.172 | 0.354 | 0.394 | 0.196 |
| BIOT | 0.282±0.113 | 0.364±0.063 | 0.381±0.054 | 0.355±0.069 | 0.269±0.092 | 0.302±0.157 | 0.308±0.137 | 0.323 | 0.381 | 0.098 |
| BrainOmni | 0.256±0.079 | 0.170±0.039 | 0.341±0.083 | 0.297±0.155 | 0.290±0.132 | 0.287±0.080 | 0.290±0.134 | 0.271 | 0.385 | 0.106 |
| CNN-Trans. | 0.219±0.086 | 0.193±0.071 | 0.308±0.220 | 0.356±0.109 | 0.553±0.034 | 0.255±0.039 | 0.325±0.161 | 0.355 | 0.377 | 0.187 |
| ContraWR | 0.162±0.048 | 0.251±0.097 | 0.257±0.104 | 0.344±0.102 | 0.444±0.046 | 0.556±0.089 | 0.313±0.116 | 0.304 | 0.401 | 0.122 |
| FFCL | 0.215±0.058 | 0.267±0.099 | 0.372±0.065 | 0.376±0.063 | 0.387±0.057 | 0.289±0.141 | 0.291±0.149 | 0.314 | 0.399 | 0.144 |
| LaBraM | 0.326±0.100 | 0.285±0.120 | 0.356±0.069 | 0.323±0.106 | 0.467±0.032 | 0.399±0.048 | 0.319±0.113 | 0.353 | 0.382 | 0.179 |
| SIREN-based | 0.237±0.066 | 0.293±0.146 | 0.323±0.108 | 0.313±0.129 | 0.537±0.025 | 0.544±0.024 | 0.282±0.119 | 0.361 | 0.380 | 0.173 |
| REVE | 0.302±0.115 | 0.337±0.063 | 0.319±0.081 | 0.306±0.106 | 0.404±0.034 | 0.546±0.056 | 0.308±0.101 | 0.332 | 0.382 | 0.094 |
| SPaRCNet | 0.178±0.073 | 0.153±0.063 | 0.293±0.250 | 0.224±0.102 | 0.610±0.041 | 0.526±0.041 | 0.249±0.131 | 0.322 | 0.384 | 0.147 |
| STT-Trans. | 0.398±0.047 | 0.361±0.064 | 0.408±0.044 | 0.078±0.025 | 0.306±0.141 | 0.533±0.070 | 0.314±0.122 | 0.317 | 0.406 | 0.137 |
| NVCode (Ours) | 0.324±0.134 | 0.361±0.197 | 0.428±0.229 | 0.395±0.349 | 0.768±0.038 | 0.742±0.041 | 0.436±0.206 | 0.493 | 0.380 | 0.105 |
Table 11b. Encoder comparison on MULTI-CLARID (Resting State).
| Encoder | Cuneus | Heschl’s Gyrus | Middle Frontal | Precuneus | Putamen | Thalamus | Global Signal | Avg. R↑ | CRPS↓ | FC-MAE↓ |
| Intra subject | ||||||||||
| BEIRA | 0.476±0.173 | 0.316±0.199 | 0.322±0.191 | 0.380±0.139 | 0.431±0.155 | 0.296±0.183 | 0.439±0.172 | 0.380 | 0.383 | 0.359 |
| BIOT | 0.345±0.142 | 0.249±0.148 | 0.208±0.132 | 0.289±0.134 | 0.279±0.124 | 0.375±0.141 | 0.315±0.110 | 0.294 | 0.332 | 0.326 |
| BrainOmni | 0.214±0.118 | 0.346±0.117 | 0.388±0.146 | 0.313±0.152 | 0.333±0.152 | 0.309±0.126 | 0.290±0.158 | 0.313 | 0.333 | 0.332 |
| CNN-Trans. | 0.332±0.126 | 0.363±0.140 | 0.446±0.129 | 0.409±0.153 | 0.464±0.151 | 0.344±0.149 | 0.409±0.166 | 0.395 | 0.330 | 0.336 |
| ContraWR | 0.347±0.163 | 0.447±0.164 | 0.399±0.144 | 0.478±0.181 | 0.545±0.157 | 0.400±0.168 | 0.509±0.161 | 0.447 | 0.352 | 0.353 |
| FFCL | 0.344±0.163 | 0.378±0.165 | 0.347±0.169 | 0.446±0.161 | 0.382±0.151 | 0.393±0.146 | 0.365±0.159 | 0.379 | 0.359 | 0.368 |
| LaBraM | 0.417±0.130 | 0.384±0.161 | 0.388±0.146 | 0.245±0.093 | 0.336±0.152 | 0.294±0.140 | 0.325±0.138 | 0.341 | 0.333 | 0.326 |
| SIREN-based | 0.383±0.165 | 0.446±0.158 | 0.393±0.142 | 0.483±0.137 | 0.439±0.148 | 0.448±0.149 | 0.441±0.155 | 0.433 | 0.329 | 0.354 |
| REVE | 0.337±0.136 | 0.410±0.144 | 0.313±0.135 | 0.281±0.131 | 0.331±0.132 | 0.377±0.135 | 0.287±0.137 | 0.334 | 0.335 | 0.357 |
| SPaRCNet | 0.311±0.143 | 0.412±0.150 | 0.493±0.168 | 0.265±0.116 | 0.411±0.153 | 0.361±0.149 | 0.400±0.145 | 0.379 | 0.345 | 0.372 |
| STT-Trans. | 0.395±0.140 | 0.411±0.128 | 0.393±0.126 | 0.303±0.146 | 0.308±0.127 | 0.359±0.154 | 0.311±0.150 | 0.354 | 0.337 | 0.346 |
| NVCode (Ours) | 0.392±0.200 | 0.601±0.181 | 0.424±0.144 | 0.463±0.180 | 0.577±0.188 | 0.538±0.174 | 0.609±0.166 | 0.515 | 0.329 | 0.309 |
| Inter subject | ||||||||||
| BEIRA | 0.238±0.133 | 0.412±0.089 | 0.221±0.114 | 0.359±0.137 | 0.250±0.151 | 0.256±0.162 | 0.302±0.324 | 0.291 | 0.318 | 0.149 |
| BIOT | 0.182±0.116 | 0.183±0.117 | 0.177±0.113 | 0.274±0.277 | 0.267±0.252 | 0.309±0.376 | 0.353±0.198 | 0.249 | 0.321 | 0.104 |
| BrainOmni | 0.210±0.124 | 0.287±0.306 | 0.204±0.119 | 0.249±0.177 | 0.272±0.235 | 0.362±0.157 | 0.361±0.160 | 0.278 | 0.318 | 0.098 |
| CNN-Trans. | 0.275±0.169 | 0.230±0.100 | 0.245±0.115 | 0.268±0.154 | 0.351±0.121 | 0.301±0.271 | 0.214±0.087 | 0.269 | 0.321 | 0.064 |
| ContraWR | 0.175±0.106 | 0.222±0.148 | 0.431±0.102 | 0.217±0.142 | 0.290±0.349 | 0.174±0.105 | 0.176±0.106 | 0.241 | 0.325 | 0.210 |
| FFCL | 0.245±0.187 | 0.268±0.248 | 0.299±0.400 | 0.051±0.061 | 0.058±0.063 | 0.118±0.080 | 0.158±0.098 | 0.171 | 0.328 | 0.112 |
| LaBraM | 0.243±0.114 | 0.266±0.151 | 0.313±0.209 | 0.149±0.058 | 0.301±0.269 | 0.280±0.184 | 0.200±0.079 | 0.250 | 0.319 | 0.085 |
| SIREN-based | 0.365±0.342 | 0.546±0.126 | 0.505±0.147 | 0.378±0.306 | 0.469±0.173 | 0.380±0.301 | 0.554±0.123 | 0.457 | 0.311 | 0.131 |
| REVE | 0.205±0.122 | 0.227±0.145 | 0.195±0.113 | 0.116±0.073 | 0.469±0.109 | 0.234±0.155 | 0.305±0.367 | 0.210 | 0.323 | 0.145 |
| SPaRCNet | 0.485±0.142 | 0.579±0.100 | 0.355±0.336 | 0.268±0.400 | 0.516±0.125 | 0.419±0.201 | 0.498±0.134 | 0.446 | 0.313 | 0.137 |
| STT-Trans. | 0.248±0.158 | 0.257±0.176 | 0.222±0.123 | 0.463±0.072 | 0.258±0.178 | 0.263±0.190 | 0.292±0.252 | 0.285 | 0.319 | 0.153 |
| NVCode (Ours) | 0.576±0.219 | 0.560±0.236 | 0.482±0.388 | 0.222±0.217 | 0.509±0.317 | 0.412±0.400 | 0.587±0.208 | 0.478 | 0.314 | 0.044 |
Table 11c. Encoder comparison on gradCPT (Resting State).
| Encoder | Cuneus | Heschl’s Gyrus | Middle Frontal | Precuneus | Putamen | Thalamus | Global Signal | Avg. R↑ | CRPS↓ | FC-MAE↓ |
| Intra subject | ||||||||||
| BEIRA | 0.447±0.105 | 0.453±0.107 | 0.356±0.126 | 0.387±0.102 | 0.303±0.102 | 0.322±0.102 | 0.490±0.113 | 0.394 | 0.317 | 0.229 |
| BIOT | 0.212±0.066 | 0.200±0.062 | 0.219±0.063 | 0.208±0.070 | 0.144±0.059 | 0.203±0.069 | 0.210±0.072 | 0.199 | 0.305 | 0.182 |
| BrainOmni | 0.335±0.088 | 0.326±0.087 | 0.273±0.103 | 0.323±0.098 | 0.225±0.074 | 0.208±0.082 | 0.393±0.100 | 0.297 | 0.301 | 0.249 |
| CNN-Trans. | 0.411±0.108 | 0.400±0.096 | 0.326±0.112 | 0.304±0.104 | 0.292±0.074 | 0.274±0.090 | 0.400±0.110 | 0.344 | 0.314 | 0.224 |
| ContraWR | 0.386±0.106 | 0.338±0.112 | 0.256±0.092 | 0.364±0.103 | 0.237±0.094 | 0.218±0.084 | 0.402±0.109 | 0.314 | 0.347 | 0.209 |
| FFCL | 0.447±0.105 | 0.377±0.110 | 0.290±0.103 | 0.353±0.112 | 0.266±0.096 | 0.287±0.093 | 0.440±0.115 | 0.351 | 0.328 | 0.191 |
| LaBraM | 0.463±0.113 | 0.452±0.107 | 0.375±0.101 | 0.389±0.121 | 0.343±0.076 | 0.371±0.091 | 0.503±0.096 | 0.414 | 0.289 | 0.188 |
| SIREN-based | 0.527±0.096 | 0.469±0.105 | 0.427±0.080 | 0.436±0.109 | 0.348±0.092 | 0.435±0.097 | 0.562±0.093 | 0.458 | 0.300 | 0.188 |
| REVE | 0.174±0.063 | 0.149±0.062 | 0.103±0.075 | 0.161±0.067 | 0.085±0.065 | 0.058±0.059 | 0.149±0.066 | 0.125 | 0.310 | 0.259 |
| SPaRCNet | 0.531±0.098 | 0.525±0.096 | 0.379±0.109 | 0.489±0.108 | 0.305±0.104 | 0.457±0.081 | 0.647±0.081 | 0.491 | 0.312 | 0.162 |
| STT-Trans. | 0.104±0.066 | 0.203±0.070 | 0.180±0.066 | 0.136±0.068 | 0.128±0.070 | 0.106±0.082 | 0.178±0.062 | 0.148 | 0.326 | 0.231 |
| NVCode (Ours) | 0.639±0.113 | 0.671±0.107 | 0.489±0.153 | 0.564±0.130 | 0.439±0.175 | 0.515±0.145 | 0.658±0.110 | 0.567 | 0.219 | 0.167 |
| Inter subject | ||||||||||
| BEIRA | 0.379±0.052 | 0.380±0.052 | 0.282±0.071 | 0.343±0.058 | 0.126±0.176 | 0.142±0.153 | 0.389±0.051 | 0.291 | 0.290 | 0.187 |
| BIOT | 0.284±0.091 | 0.303±0.096 | 0.224±0.108 | 0.261±0.088 | 0.178±0.135 | 0.195±0.122 | 0.318±0.072 | 0.252 | 0.294 | 0.152 |
| BrainOmni | 0.291±0.067 | 0.297±0.065 | 0.228±0.087 | 0.264±0.074 | 0.160±0.129 | 0.204±0.099 | 0.346±0.056 | 0.256 | 0.293 | 0.109 |
| CNN-Trans. | 0.405±0.077 | 0.487±0.063 | 0.360±0.087 | 0.424±0.073 | 0.263±0.122 | 0.304±0.104 | 0.495±0.062 | 0.391 | 0.284 | 0.098 |
| ContraWR | 0.293±0.076 | 0.270±0.082 | 0.301±0.073 | 0.297±0.074 | 0.166±0.141 | 0.209±0.109 | 0.353±0.062 | 0.270 | 0.302 | 0.102 |
| FFCL | 0.404±0.065 | 0.394±0.067 | 0.301±0.089 | 0.314±0.085 | 0.231±0.118 | 0.252±0.108 | 0.415±0.063 | 0.330 | 0.290 | 0.101 |
| LaBraM | 0.445±0.064 | 0.447±0.064 | 0.356±0.082 | 0.421±0.068 | 0.347±0.125 | 0.352±0.082 | 0.482±0.059 | 0.388 | 0.285 | 0.065 |
| SIREN-based | 0.475±0.076 | 0.521±0.069 | 0.414±0.088 | 0.420±0.087 | 0.318±0.116 | 0.401±0.091 | 0.546±0.066 | 0.442 | 0.279 | 0.112 |
| REVE | 0.154±0.041 | 0.059±0.039 | 0.081±0.089 | 0.138±0.046 | 0.031±0.079 | 0.105±0.064 | 0.168±0.037 | 0.105 | 0.303 | 0.153 |
| SPaRCNet | 0.489±0.064 | 0.515±0.061 | 0.435±0.073 | 0.506±0.062 | 0.252±0.131 | 0.438±0.072 | 0.554±0.082 | 0.455 | 0.275 | 0.104 |
| STT-Trans. | 0.090±0.082 | 0.099±0.073 | 0.080±0.096 | 0.076±0.103 | 0.093±0.079 | 0.088±0.085 | 0.131±0.052 | 0.094 | 0.303 | 0.133 |
| NVCode (Ours) | 0.616±0.049 | 0.614±0.050 | 0.436±0.070 | 0.523±0.058 | 0.341±0.090 | 0.468±0.065 | 0.585±0.052 | 0.512 | 0.268 | 0.043 |
Table 11d. Encoder comparison on NeuroBOLT (Resting State).
| Encoder | Cuneus | Heschl’s Gyrus | Middle Frontal | Precuneus | Putamen | Thalamus | Global Signal | Avg. R↑ | CRPS↓ | FC-MAE↓ |
| Intra subject | ||||||||||
| BEIRA | 0.467 | 0.233 | 0.216 | 0.616 | 0.379 | 0.376 | 0.502 | 0.398 | 0.539 | 0.390 |
| BIOT | 0.009 | -0.054 | 0.228 | 0.246 | 0.086 | 0.086 | 0.098 | 0.100 | 0.515 | 0.413 |
| BrainOmni | 0.142 | 0.347 | 0.223 | 0.373 | 0.339 | 0.064 | 0.273 | 0.252 | 0.502 | 0.400 |
| CNN-Trans. | 0.356 | 0.447 | 0.208 | 0.184 | 0.240 | 0.212 | 0.198 | 0.263 | 0.493 | 0.408 |
| ContraWR | 0.128 | 0.171 | 0.375 | 0.121 | 0.064 | 0.119 | -0.010 | 0.138 | 0.547 | 0.431 |
| FFCL | 0.384 | -0.049 | 0.292 | 0.227 | 0.410 | 0.269 | 0.232 | 0.252 | 0.580 | 0.446 |
| LaBraM | 0.239 | 0.004 | 0.143 | 0.240 | 0.277 | 0.179 | 0.197 | 0.183 | 0.506 | 0.412 |
| SIREN-based | 0.473 | 0.418 | 0.471 | 0.236 | 0.394 | 0.408 | 0.537 | 0.420 | 0.512 | 0.388 |
| REVE | -0.097 | 0.133 | 0.011 | 0.196 | 0.218 | 0.233 | 0.286 | 0.140 | 0.511 | 0.397 |
| SPaRCNet | 0.364 | 0.250 | 0.311 | 0.067 | 0.372 | 0.329 | 0.188 | 0.269 | 0.531 | 0.419 |
| STT-Trans. | 0.263 | 0.387 | 0.226 | 0.115 | 0.213 | 0.221 | 0.285 | 0.244 | 0.512 | 0.405 |
| NVCode (Ours) | 0.707 | 0.495 | 0.291 | 0.461 | 0.608 | 0.328 | 0.536 | 0.489 | 0.432 | 0.361 |
| Inter subject | ||||||||||
| BEIRA | 0.178 | -0.076 | -0.129 | 0.024 | -0.062 | -0.141 | 0.142 | -0.009 | 0.513 | 0.269 |
| BIOT | 0.381 | 0.109 | 0.236 | 0.195 | 0.470 | 0.371 | 0.194 | 0.279 | 0.483 | 0.272 |
| BrainOmni | 0.438 | 0.224 | 0.225 | 0.365 | 0.228 | 0.348 | 0.337 | 0.310 | 0.490 | 0.314 |
| CNN-Trans. | 0.254 | 0.242 | 0.276 | 0.208 | 0.459 | 0.354 | 0.070 | 0.266 | 0.489 | 0.348 |
| ContraWR | 0.497 | 0.136 | 0.259 | 0.352 | 0.196 | 0.233 | 0.186 | 0.265 | 0.490 | 0.384 |
| FFCL | 0.485 | 0.143 | 0.211 | 0.353 | 0.307 | 0.313 | 0.125 | 0.277 | 0.493 | 0.356 |
| LaBraM | 0.428 | 0.387 | 0.202 | 0.507 | 0.280 | 0.337 | 0.307 | 0.350 | 0.480 | 0.282 |
| SIREN-based | 0.495 | 0.276 | 0.135 | 0.578 | 0.406 | 0.266 | 0.338 | 0.356 | 0.492 | 0.343 |
| REVE | 0.367 | 0.233 | 0.138 | 0.520 | 0.232 | 0.053 | 0.504 | 0.292 | 0.497 | 0.308 |
| SPaRCNet | 0.587 | 0.481 | 0.259 | 0.465 | 0.432 | 0.313 | 0.435 | 0.425 | 0.499 | 0.318 |
| STT-Trans. | 0.353 | 0.225 | 0.198 | 0.099 | 0.310 | 0.100 | 0.178 | 0.209 | 0.489 | 0.265 |
| NVCode (Ours) | 0.654 | 0.660 | 0.342 | 0.588 | -0.012 | 0.182 | 0.660 | 0.439 | 0.466 | 0.310 |
Table 11e. Encoder comparison on XP1 (Active).
| Encoder | Cuneus | Heschl’s Gyrus | Middle Frontal | Precuneus | Putamen | Thalamus | Global Signal | Avg. R↑ | CRPS↓ | FC-MAE↓ |
| Intra subject BEIRA | 0.279±0.118 | 0.413±0.137 | 0.477±0.126 | 0.317±0.107 | 0.469±0.103 | 0.455±0.108 | 0.273±0.112 | 0.383 | 0.357 | 0.283 |
| BIOT | 0.194±0.083 | 0.235±0.065 | 0.252±0.086 | 0.218±0.050 | 0.198±0.055 | 0.251±0.081 | 0.258±0.074 | 0.230 | 0.357 | 0.261 |
| BrainOmni | 0.276±0.104 | 0.320±0.085 | 0.393±0.099 | 0.293±0.086 | 0.297±0.067 | 0.354±0.063 | 0.261±0.093 | 0.313 | 0.345 | 0.248 |
| CNN-Trans. | 0.324±0.083 | 0.396±0.092 | 0.419±0.147 | 0.330±0.064 | 0.393±0.133 | 0.449±0.103 | 0.290±0.088 | 0.371 | 0.369 | 0.239 |
| ContraWR | 0.314±0.123 | 0.367±0.091 | 0.553±0.116 | 0.314±0.111 | 0.410±0.117 | 0.481±0.105 | 0.265±0.092 | 0.386 | 0.396 | 0.248 |
| FFCL | 0.309±0.117 | 0.360±0.094 | 0.476±0.108 | 0.255±0.092 | 0.396±0.122 | 0.486±0.074 | 0.278±0.079 | 0.366 | 0.405 | 0.245 |
| LaBraM | 0.250±0.074 | 0.270±0.097 | 0.299±0.121 | 0.172±0.088 | 0.282±0.089 | 0.367±0.093 | 0.210±0.072 | 0.264 | 0.360 | 0.243 |
| SIREN-based | 0.311±0.097 | 0.463±0.099 | 0.446±0.088 | 0.294±0.080 | 0.450±0.112 | 0.469±0.110 | 0.311±0.074 | 0.392 | 0.386 | 0.241 |
| REVE | 0.202±0.049 | 0.259±0.051 | 0.245±0.059 | 0.213±0.047 | 0.274±0.055 | 0.289±0.056 | 0.216±0.055 | 0.242 | 0.360 | 0.246 |
| SPaRCNet | 0.324±0.132 | 0.426±0.099 | 0.357±0.140 | 0.336±0.095 | 0.376±0.145 | 0.387±0.112 | 0.269±0.088 | 0.353 | 0.382 | 0.261 |
| STT-Trans. | 0.207±0.104 | 0.252±0.077 | 0.316±0.110 | 0.225±0.071 | 0.170±0.094 | 0.215±0.085 | 0.204±0.066 | 0.227 | 0.423 | 0.229 |
| NVCode (Ours) | 0.405±0.084 | 0.542±0.100 | 0.496±0.113 | 0.442±0.069 | 0.491±0.098 | 0.543±0.120 | 0.381±0.121 | 0.471 | 0.395 | 0.226 |
| Inter subject BEIRA | 0.328±0.056 | 0.341±0.052 | 0.434±0.034 | 0.337±0.053 | 0.285±0.075 | 0.412±0.037 | 0.219±0.158 | 0.337 | 0.344 | 0.158 |
| BIOT | 0.229±0.056 | 0.289±0.030 | 0.190±0.077 | 0.263±0.037 | 0.227±0.057 | 0.196±0.087 | 0.150±0.043 | 0.220 | 0.339 | 0.160 |
| BrainOmni | 0.253±0.085 | 0.263±0.076 | 0.452±0.027 | 0.439±0.028 | 0.323±0.048 | 0.361±0.039 | 0.283±0.064 | 0.339 | 0.328 | 0.157 |
| CNN-Trans. | 0.207±0.079 | 0.237±0.048 | 0.183±0.066 | 0.109±0.029 | 0.163±0.048 | 0.186±0.070 | 0.217±0.065 | 0.186 | 0.335 | 0.112 |
| ContraWR | 0.465±0.042 | 0.376±0.059 | 0.508±0.037 | 0.430±0.047 | 0.342±0.070 | 0.473±0.041 | 0.286±0.101 | 0.411 | 0.345 | 0.211 |
| FFCL | 0.349±0.072 | 0.368±0.065 | 0.485±0.042 | 0.474±0.043 | 0.335±0.077 | 0.491±0.041 | 0.339±0.076 | 0.406 | 0.344 | 0.161 |
| LaBraM | 0.219±0.090 | 0.200±0.130 | 0.318±0.033 | 0.360±0.026 | 0.251±0.058 | 0.292±0.040 | 0.280±0.044 | 0.274 | 0.344 | 0.123 |
| SIREN-based | 0.321±0.050 | 0.353±0.042 | 0.317±0.052 | 0.363±0.040 | 0.194±0.176 | 0.397±0.034 | 0.221±0.133 | 0.309 | 0.335 | 0.137 |
| REVE | 0.267±0.044 | 0.266±0.045 | 0.310±0.032 | 0.242±0.047 | 0.214±0.061 | 0.176±0.074 | 0.218±0.089 | 0.227 | 0.337 | 0.177 |
| SPaRCNet | 0.498±0.029 | 0.411±0.040 | 0.365±0.048 | 0.353±0.051 | 0.388±0.044 | 0.335±0.057 | 0.198±0.234 | 0.364 | 0.334 | 0.143 |
| STT-Trans. | 0.228±0.066 | 0.295±0.033 | 0.159±0.055 | 0.194±0.096 | 0.278±0.038 | 0.243±0.053 | 0.142±0.045 | 0.220 | 0.380 | 0.131 |
| NVCode (Ours) | 0.406±0.094 | 0.366±0.130 | 0.494±0.059 | 0.451±0.072 | 0.266±0.187 | 0.331±0.194 | 0.389±0.108 | 0.386 | 0.351 | 0.167 |
Table 11f. Encoder comparison on Affective Music (Active).
| Encoder | Cuneus | Heschl’s Gyrus | Middle Frontal | Precuneus | Putamen | Thalamus | Global Signal | Avg. R↑ | CRPS↓ | FC-MAE↓ |
| Intra subject BEIRA | 0.446±0.110 | 0.426±0.111 | 0.360±0.108 | 0.467±0.104 | 0.367±0.096 | 0.410±0.099 | 0.430±0.104 | 0.415 | 0.368 | 0.337 |
| BIOT | 0.409±0.089 | 0.314±0.077 | 0.341±0.075 | 0.433±0.089 | 0.385±0.082 | 0.403±0.070 | 0.371±0.094 | 0.379 | 0.338 | 0.292 |
| BrainOmni | 0.331±0.073 | 0.335±0.059 | 0.422±0.072 | 0.375±0.076 | 0.336±0.068 | 0.414±0.064 | 0.320±0.076 | 0.362 | 0.343 | 0.323 |
| CNN-Trans. | 0.436±0.075 | 0.415±0.085 | 0.382±0.095 | 0.314±0.079 | 0.443±0.089 | 0.395±0.089 | 0.393±0.094 | 0.397 | 0.339 | 0.337 |
| ContraWR | 0.450±0.101 | 0.432±0.089 | 0.460±0.098 | 0.373±0.098 | 0.386±0.077 | 0.379±0.082 | 0.388±0.099 | 0.410 | 0.352 | 0.340 |
| FFCL | 0.435±0.119 | 0.416±0.100 | 0.424±0.113 | 0.416±0.116 | 0.382±0.086 | 0.405±0.098 | 0.369±0.110 | 0.407 | 0.356 | 0.325 |
| LaBraM | 0.369±0.077 | 0.333±0.079 | 0.377±0.074 | 0.399±0.089 | 0.375±0.077 | 0.375±0.077 | 0.283±0.099 | 0.359 | 0.340 | 0.289 |
| SIREN-based | 0.469±0.101 | 0.490±0.079 | 0.373±0.096 | 0.413±0.090 | 0.430±0.091 | 0.426±0.092 | 0.444±0.068 | 0.435 | 0.352 | 0.331 |
| REVE | 0.420±0.089 | 0.313±0.082 | 0.290±0.071 | 0.363±0.075 | 0.394±0.084 | 0.379±0.083 | 0.319±0.065 | 0.354 | 0.346 | 0.322 |
| SPaRCNet | 0.459±0.128 | 0.322±0.095 | 0.399±0.100 | 0.431±0.104 | 0.419±0.095 | 0.468±0.103 | 0.412±0.092 | 0.416 | 0.388 | 0.349 |
| STT-Trans. | 0.395±0.075 | 0.346±0.082 | 0.425±0.091 | 0.315±0.084 | 0.320±0.079 | 0.377±0.081 | 0.354±0.087 | 0.363 | 0.343 | 0.300 |
| NVCode (Ours) | 0.452±0.117 | 0.527±0.119 | 0.306±0.089 | 0.363±0.108 | 0.478±0.107 | 0.447±0.106 | 0.478±0.113 | 0.436 | 0.351 | 0.274 |
| Inter subject BEIRA | 0.154±0.040 | 0.209±0.055 | 0.115±0.034 | 0.206±0.054 | 0.307±0.158 | 0.283±0.164 | 0.283±0.108 | 0.229 | 0.331 | 0.100 |
| BIOT | 0.147±0.039 | 0.303±0.146 | 0.281±0.106 | 0.269±0.092 | 0.262±0.085 | 0.231±0.065 | 0.183±0.047 | 0.239 | 0.335 | 0.130 |
| BrainOmni | 0.347±0.108 | 0.246±0.063 | 0.272±0.082 | 0.290±0.102 | 0.306±0.134 | 0.377±0.074 | 0.283±0.083 | 0.303 | 0.328 | 0.080 |
| CNN-Trans. | 0.175±0.051 | 0.345±0.146 | 0.150±0.054 | 0.302±0.163 | 0.203±0.060 | 0.290±0.116 | 0.224±0.098 | 0.245 | 0.334 | 0.089 |
| ContraWR | 0.059±0.037 | 0.209±0.074 | 0.297±0.178 | 0.251±0.102 | 0.262±0.114 | 0.240±0.093 | 0.290±0.159 | 0.230 | 0.345 | 0.135 |
| FFCL | 0.170±0.036 | 0.346±0.103 | 0.328±0.142 | 0.278±0.083 | 0.462±0.037 | 0.275±0.080 | 0.434±0.044 | 0.327 | 0.339 | 0.125 |
| LaBraM | 0.298±0.135 | 0.309±0.164 | 0.250±0.076 | 0.395±0.073 | 0.456±0.048 | 0.348±0.124 | 0.380±0.085 | 0.348 | 0.326 | 0.092 |
| SIREN-based | 0.258±0.098 | 0.278±0.123 | 0.290±0.143 | 0.261±0.101 | 0.249±0.091 | 0.246±0.088 | 0.251±0.092 | 0.262 | 0.328 | 0.087 |
| REVE | 0.156±0.045 | 0.300±0.154 | 0.199±0.058 | 0.260±0.092 | 0.256±0.089 | 0.311±0.190 | 0.206±0.066 | 0.241 | 0.334 | 0.049 |
| SPaRCNet | 0.286±0.072 | 0.377±0.057 | 0.339±0.090 | 0.321±0.128 | 0.295±0.081 | 0.336±0.094 | 0.277±0.064 | 0.318 | 0.329 | 0.070 |
| STT-Trans. | 0.195±0.053 | 0.307±0.163 | 0.195±0.053 | 0.172±0.046 | 0.326±0.189 | 0.261±0.088 | 0.205±0.056 | 0.237 | 0.334 | 0.090 |
| NVCode (Ours) | 0.235±0.126 | 0.348±0.232 | 0.342±0.256 | 0.378±0.160 | 0.575±0.053 | 0.423±0.111 | 0.440±0.098 | 0.392 | 0.332 | 0.066 |
Table 11g. Encoder comparison on Experience Sampling (Active).
| Encoder | Cuneus | Heschl’s Gyrus | Middle Frontal | Precuneus | Putamen | Thalamus | Global Signal | Avg. R↑ | CRPS↓ | FC-MAE↓ |
| Intra subject BEIRA | -0.418 | 0.406 | -0.671 | -0.105 | 0.221 | -0.155 | 0.236 | -0.070 | 0.347 | 0.456 |
| BIOT | 0.341 | 0.072 | 0.521 | -0.075 | 0.436 | -0.026 | 0.228 | 0.214 | 0.307 | 0.563 |
| BrainOmni | -0.085 | 0.652 | -0.085 | 0.107 | -0.187 | 0.012 | -0.051 | -0.034 | 0.312 | 0.529 |
| CNN-Trans. | -0.646 | 0.506 | -0.620 | 0.190 | 0.205 | 0.053 | 0.187 | -0.018 | 0.301 | 0.521 |
| ContraWR | 0.100 | 0.471 | -0.269 | 0.198 | 0.095 | -0.313 | 0.494 | 0.111 | 0.328 | 0.585 |
| FFCL | 0.053 | -0.260 | 0.111 | -0.214 | 0.267 | -0.378 | -0.238 | -0.094 | 0.271 | 0.618 |
| LaBraM | -0.207 | -0.479 | -0.003 | 0.150 | 0.024 | -0.114 | -0.301 | -0.133 | 0.309 | 0.521 |
| SIREN-based | 0.607 | 0.059 | 0.106 | -0.174 | 0.405 | 0.106 | 0.148 | 0.180 | 0.405 | 0.448 |
| REVE | -0.712 | 0.428 | 0.150 | 0.062 | -0.102 | -0.816 | 0.213 | -0.111 | 0.295 | 0.517 |
| SPaRCNet | -0.133 | -0.066 | -0.185 | -0.477 | -0.148 | -0.049 | 0.447 | -0.177 | 0.300 | 0.453 |
| STT-Trans. | 0.168 | -0.047 | -0.178 | 0.244 | 0.004 | 0.398 | -0.308 | 0.040 | 0.314 | 0.462 |
| NVCode (Ours) | 0.103 | 0.184 | 0.082 | 0.816 | 0.194 | 0.301 | 0.518 | 0.314 | 0.368 | 0.385 |
| Inter subject BEIRA | 0.422 | -0.541 | -0.538 | -0.570 | -0.711 | -0.760 | -0.714 | -0.488 | 0.426 | 0.453 |
| BIOT | 0.115 | -0.238 | -0.102 | 0.676 | -0.150 | 0.341 | 0.039 | 0.097 | 0.297 | 0.358 |
| BrainOmni | -0.267 | 0.722 | 0.125 | 0.290 | 0.616 | 0.103 | -0.150 | 0.205 | 0.292 | 0.387 |
| CNN-Trans. | 0.726 | 0.369 | -0.260 | 0.088 | 0.103 | -0.232 | -0.602 | 0.070 | 0.300 | 0.525 |
| ContraWR | -0.265 | -0.734 | 0.299 | 0.229 | -0.357 | -0.057 | -0.773 | -0.237 | 0.320 | 0.398 |
| FFCL | 0.208 | 0.025 | -0.019 | 0.027 | -0.547 | 0.129 | -0.589 | -0.109 | 0.375 | 0.475 |
| LaBraM | 0.163 | 0.420 | 0.272 | 0.147 | -0.127 | 0.002 | -0.107 | 0.110 | 0.288 | 0.544 |
| SIREN-based | 0.291 | -0.031 | -0.727 | -0.137 | -0.480 | -0.227 | -0.278 | -0.227 | 0.379 | 0.372 |
| REVE | 0.051 | 0.067 | -0.172 | -0.242 | -0.195 | -0.529 | -0.346 | -0.195 | 0.294 | 0.544 |
| SPaRCNet | 0.406 | -0.149 | 0.429 | -0.027 | -0.095 | -0.043 | -0.010 | 0.073 | 0.289 | 0.296 |
| STT-Trans. | 0.011 | -0.135 | 0.543 | -0.060 | -0.014 | 0.073 | -0.065 | 0.050 | 0.320 | 0.288 |
| NVCode (Ours) | 0.127 | 0.274 | 0.394 | -0.003 | 0.235 | 0.177 | 0.369 | 0.225 | 0.311 | 0.249 |
Table 11h. Encoder comparison on NatView (Active).
Per Dataset Generator Results
All generation networks share the seven frozen NVCode encoders and the frozen NVCode-trained projector. Each table reports the two evaluation splits for one dataset using the same aggregation and ranking conventions as the encoder tables.
| Generator | Cuneus | Heschl’s Gyrus | Middle Frontal | Precuneus | Putamen | Thalamus | Global Signal | Avg. R↑ | CRPS↓ | FC-MAE↓ |
| cGAN | 0.276±0.152 | 0.307±0.113 | 0.440±0.111 | 0.330±0.115 | 0.398±0.103 | 0.358±0.139 | 0.304±0.146 | 0.344 | 0.459 | 0.567 |
| Consistency | 0.413±0.108 | 0.405±0.109 | 0.471±0.136 | 0.383±0.110 | 0.326±0.109 | 0.379±0.096 | 0.396±0.154 | 0.396 | 0.439 | 0.287 |
| CVAE | 0.538±0.126 | 0.438±0.112 | 0.573±0.149 | 0.432±0.149 | 0.428±0.136 | 0.325±0.140 | 0.489±0.142 | 0.461 | 0.351 | 0.276 |
| DDPM | 0.491±0.132 | 0.496±0.112 | 0.436±0.134 | 0.407±0.161 | 0.424±0.146 | 0.386±0.127 | 0.405±0.133 | 0.435 | 0.343 | 0.249 |
| EDM | 0.436±0.154 | 0.510±0.173 | 0.550±0.116 | 0.524±0.176 | 0.472±0.182 | 0.388±0.174 | 0.529±0.177 | 0.487 | 0.340 | 0.258 |
| Rectified Flow | 0.467±0.150 | 0.437±0.131 | 0.428±0.116 | 0.438±0.098 | 0.457±0.106 | 0.458±0.116 | 0.363±0.135 | 0.435 | 0.346 | 0.280 |
| Score SDE | 0.455±0.116 | 0.554±0.138 | 0.422±0.145 | 0.472±0.138 | 0.463±0.143 | 0.408±0.149 | 0.499±0.120 | 0.468 | 0.343 | 0.299 |
| NVCode (Ours) | 0.366±0.175 | 0.522±0.186 | 0.472±0.143 | 0.524±0.135 | 0.608±0.118 | 0.491±0.131 | 0.534±0.145 | 0.502 | 0.339 | 0.239 |
| cGAN | 0.400±0.113 | 0.412±0.110 | 0.330±0.134 | 0.219±0.192 | 0.310±0.142 | 0.306±0.143 | 0.384±0.117 | 0.337 | 0.338 | 0.180 |
| Consistency | 0.425±0.105 | 0.450±0.099 | 0.399±0.111 | 0.381±0.116 | 0.383±0.115 | 0.316±0.137 | 0.365±0.120 | 0.388 | 0.433 | 0.169 |
| CVAE | 0.267±0.252 | 0.642±0.113 | 0.470±0.151 | 0.436±0.162 | 0.433±0.163 | 0.462±0.154 | 0.437±0.162 | 0.449 | 0.334 | 0.272 |
| DDPM | 0.261±0.157 | 0.443±0.098 | 0.357±0.119 | 0.364±0.117 | 0.317±0.132 | 0.340±0.124 | 0.396±0.108 | 0.354 | 0.331 | 0.128 |
| EDM | 0.220±0.214 | 0.589±0.088 | 0.362±0.138 | 0.312±0.158 | 0.339±0.146 | 0.405±0.125 | 0.352±0.141 | 0.368 | 0.335 | 0.173 |
| Rectified Flow | 0.381±0.139 | 0.446±0.121 | 0.446±0.120 | 0.254±0.199 | 0.276±0.185 | 0.349±0.151 | 0.475±0.114 | 0.375 | 0.336 | 0.189 |
| Score SDE | 0.290±0.178 | 0.594±0.092 | 0.399±0.133 | 0.322±0.162 | 0.371±0.143 | 0.406±0.132 | 0.335±0.156 | 0.388 | 0.329 | 0.157 |
| NVCode (Ours) | 0.194±0.207 | 0.613±0.142 | 0.553±0.178 | 0.410±0.400 | 0.557±0.175 | 0.433±0.362 | 0.430±0.373 | 0.456 | 0.327 | 0.096 |
Table 12a. Generator comparison on Sleep EEG–fMRI (Resting State).
| Generator | Cuneus | Heschl’s Gyrus | Middle Frontal | Precuneus | Putamen | Thalamus | Global Signal | Avg. R↑ | CRPS↓ | FC-MAE↓ |
| cGAN | 0.374±0.107 | 0.365±0.125 | 0.415±0.108 | 0.414±0.092 | 0.571±0.101 | 0.504±0.117 | 0.382±0.116 | 0.432 | 0.519 | 0.548 |
| Consistency | 0.400±0.087 | 0.400±0.109 | 0.414±0.106 | 0.376±0.099 | 0.428±0.105 | 0.447±0.112 | 0.311±0.101 | 0.397 | 0.505 | 0.386 |
| CVAE | 0.390±0.108 | 0.408±0.116 | 0.459±0.131 | 0.395±0.088 | 0.566±0.116 | 0.509±0.131 | 0.377±0.111 | 0.444 | 0.431 | 0.331 |
| DDPM | 0.341±0.094 | 0.401±0.102 | 0.438±0.119 | 0.331±0.080 | 0.512±0.119 | 0.479±0.134 | 0.366±0.107 | 0.410 | 0.397 | 0.334 |
| EDM | 0.420±0.094 | 0.405±0.104 | 0.458±0.107 | 0.389±0.084 | 0.506±0.118 | 0.477±0.122 | 0.343±0.099 | 0.428 | 0.413 | 0.322 |
| Rectified Flow | 0.405±0.081 | 0.382±0.113 | 0.434±0.103 | 0.425±0.089 | 0.484±0.118 | 0.469±0.114 | 0.321±0.097 | 0.417 | 0.417 | 0.359 |
| Score SDE | 0.363±0.090 | 0.386±0.119 | 0.425±0.119 | 0.333±0.091 | 0.552±0.102 | 0.472±0.118 | 0.350±0.104 | 0.411 | 0.409 | 0.327 |
| NVCode (Ours) | 0.524±0.100 | 0.484±0.128 | 0.639±0.124 | 0.416±0.095 | 0.606±0.119 | 0.650±0.117 | 0.482±0.124 | 0.543 | 0.384 | 0.276 |
| cGAN | 0.316±0.106 | 0.378±0.091 | 0.461±0.076 | 0.365±0.099 | 0.695±0.052 | 0.654±0.055 | 0.363±0.094 | 0.462 | 0.394 | 0.263 |
| Consistency | 0.354±0.092 | 0.270±0.117 | 0.466±0.072 | 0.385±0.085 | 0.697±0.049 | 0.666±0.055 | 0.306±0.091 | 0.457 | 0.472 | 0.292 |
| CVAE | 0.389±0.092 | 0.318±0.111 | 0.447±0.081 | 0.328±0.108 | 0.694±0.054 | 0.627±0.059 | 0.376±0.095 | 0.454 | 0.381 | 0.191 |
| DDPM | 0.399±0.104 | 0.316±0.128 | 0.418±0.099 | 0.469±0.090 | 0.616±0.069 | 0.538±0.079 | 0.300±0.134 | 0.437 | 0.382 | 0.101 |
| EDM | 0.339±0.113 | 0.315±0.121 | 0.436±0.090 | 0.390±0.100 | 0.632±0.068 | 0.591±0.068 | 0.459±0.086 | 0.452 | 0.374 | 0.089 |
| Rectified Flow | 0.368±0.078 | 0.207±0.129 | 0.415±0.070 | 0.313±0.090 | 0.705±0.043 | 0.629±0.047 | 0.362±0.074 | 0.429 | 0.377 | 0.135 |
| Score SDE | 0.382±0.094 | 0.265±0.131 | 0.331±0.107 | 0.322±0.110 | 0.695±0.054 | 0.614±0.061 | 0.308±0.114 | 0.417 | 0.379 | 0.203 |
| NVCode (Ours) | 0.324±0.134 | 0.361±0.197 | 0.428±0.229 | 0.395±0.349 | 0.768±0.038 | 0.742±0.041 | 0.436±0.206 | 0.493 | 0.380 | 0.105 |
Table 12b. Generator comparison on MULTI-CLARID (Resting State).
| Generator | Cuneus | Heschl’s Gyrus | Middle Frontal | Precuneus | Putamen | Thalamus | Global Signal | Avg. R↑ | CRPS↓ | FC-MAE↓ |
| cGAN | 0.285±0.163 | 0.272±0.160 | 0.398±0.126 | 0.369±0.142 | 0.404±0.131 | 0.377±0.165 | 0.319±0.142 | 0.346 | 0.451 | 0.533 |
| Consistency | 0.389±0.115 | 0.385±0.125 | 0.361±0.097 | 0.335±0.121 | 0.356±0.104 | 0.370±0.129 | 0.377±0.095 | 0.367 | 0.418 | 0.357 |
| CVAE | 0.394±0.157 | 0.315±0.166 | 0.480±0.124 | 0.333±0.169 | 0.374±0.156 | 0.228±0.129 | 0.326±0.138 | 0.350 | 0.345 | 0.348 |
| DDPM | 0.330±0.154 | 0.300±0.167 | 0.391±0.143 | 0.441±0.140 | 0.425±0.171 | 0.353±0.142 | 0.396±0.171 | 0.377 | 0.332 | 0.327 |
| EDM | 0.428±0.131 | 0.436±0.175 | 0.383±0.144 | 0.393±0.136 | 0.463±0.149 | 0.423±0.140 | 0.420±0.151 | 0.421 | 0.330 | 0.324 |
| Rectified Flow | 0.507±0.118 | 0.416±0.148 | 0.312±0.147 | 0.344±0.152 | 0.411±0.156 | 0.461±0.138 | 0.425±0.143 | 0.392 | 0.333 | 0.332 |
| Score SDE | 0.255±0.136 | 0.444±0.138 | 0.379±0.151 | 0.518±0.138 | 0.427±0.133 | 0.417±0.148 | 0.401±0.152 | 0.406 | 0.333 | 0.359 |
| NVCode (Ours) | 0.392±0.200 | 0.601±0.181 | 0.424±0.144 | 0.463±0.181 | 0.577±0.188 | 0.583±0.174 | 0.509±0.166 | 0.515 | 0.329 | 0.309 |
| cGAN | 0.292±0.228 | 0.427±0.162 | 0.284±0.233 | 0.403±0.171 | 0.408±0.169 | 0.366±0.186 | 0.413±0.167 | 0.370 | 0.317 | 0.161 |
| Consistency | 0.325±0.152 | 0.244±0.195 | 0.298±0.164 | 0.342±0.145 | 0.399±0.126 | 0.341±0.145 | 0.425±0.119 | 0.339 | 0.410 | 0.195 |
| CVAE | 0.385±0.153 | 0.417±0.142 | 0.355±0.164 | 0.088±0.400 | 0.441±0.135 | 0.350±0.166 | 0.463±0.129 | 0.357 | 0.322 | 0.188 |
| DDPM | 0.315±0.195 | 0.437±0.145 | 0.353±0.176 | 0.324±0.190 | 0.458±0.139 | 0.357±0.174 | 0.459±0.139 | 0.386 | 0.317 | 0.082 |
| EDM | 0.436±0.144 | 0.420±0.149 | 0.257±0.231 | 0.347±0.177 | 0.449±0.140 | 0.321±0.190 | 0.445±0.120 | 0.383 | 0.317 | 0.131 |
| Rectified Flow | 0.361±0.144 | 0.326±0.158 | 0.313±0.164 | 0.146±0.311 | 0.321±0.161 | 0.298±0.172 | 0.445±0.120 | 0.316 | 0.325 | 0.178 |
| Score SDE | 0.451±0.158 | 0.409±0.172 | 0.380±0.184 | 0.267±0.253 | 0.433±0.164 | 0.340±0.204 | 0.449±0.158 | 0.390 | 0.321 | 0.182 |
| NVCode (Ours) | 0.576±0.219 | 0.560±0.236 | 0.482±0.388 | 0.222±0.217 | 0.509±0.317 | 0.412±0.400 | 0.587±0.208 | 0.478 | 0.314 | 0.044 |
Table 12c. Generator comparison on gradCPT (Resting State).
| Generator | Cuneus | Heschl’s Gyrus | Middle Frontal | Precuneus | Putamen | Thalamus | Global Signal | Avg. R↑ | CRPS↓ | FC-MAE↓ |
| cGAN | 0.459±0.106 | 0.418±0.095 | 0.271±0.083 | 0.367±0.081 | 0.213±0.099 | 0.266±0.089 | 0.444±0.090 | 0.348 | 0.326 | 0.198 |
| Consistency | 0.370±0.104 | 0.375±0.100 | 0.228±0.093 | 0.277±0.117 | 0.114±0.091 | 0.192±0.086 | 0.317±0.120 | 0.268 | 0.378 | 0.228 |
| CVAE | 0.487±0.113 | 0.458±0.084 | 0.312±0.110 | 0.384±0.109 | 0.272±0.088 | 0.264±0.097 | 0.480±0.098 | 0.380 | 0.300 | 0.185 |
| DDPM | 0.451±0.108 | 0.407±0.076 | 0.199±0.096 | 0.319±0.097 | 0.211±0.101 | 0.203±0.090 | 0.414±0.098 | 0.315 | 0.287 | 0.187 |
| EDM | 0.491±0.099 | 0.445±0.091 | 0.301±0.098 | 0.376±0.111 | 0.225±0.089 | 0.258±0.103 | 0.463±0.102 | 0.366 | 0.288 | 0.199 |
| Rectified Flow | 0.449±0.113 | 0.433±0.100 | 0.274±0.093 | 0.363±0.103 | 0.215±0.098 | 0.271±0.082 | 0.436±0.108 | 0.349 | 0.290 | 0.180 |
| Score SDE | 0.472±0.105 | 0.450±0.087 | 0.315±0.085 | 0.379±0.095 | 0.235±0.092 | 0.282±0.083 | 0.461±0.094 | 0.371 | 0.282 | 0.193 |
| NVCode (Ours) | 0.639±0.113 | 0.671±0.107 | 0.489±0.153 | 0.564±0.130 | 0.439±0.175 | 0.515±0.145 | 0.653±0.110 | 0.567 | 0.219 | 0.167 |
| cGAN | 0.569±0.059 | 0.515±0.064 | 0.374±0.086 | 0.474±0.069 | 0.257±0.120 | 0.287±0.109 | 0.519±0.064 | 0.428 | 0.276 | 0.227 |
| Consistency | 0.567±0.057 | 0.506±0.064 | 0.367±0.085 | 0.467±0.069 | 0.223±0.132 | 0.281±0.108 | 0.525±0.062 | 0.420 | 0.359 | 0.182 |
| CVAE | 0.580±0.055 | 0.501±0.063 | 0.340±0.090 | 0.444±0.071 | 0.235±0.125 | 0.255±0.116 | 0.503±0.063 | 0.408 | 0.271 | 0.237 |
| DDPM | 0.540±0.050 | 0.482±0.056 | 0.304±0.085 | 0.399±0.066 | 0.165±0.142 | 0.270±0.094 | 0.470±0.057 | 0.376 | 0.280 | 0.079 |
| EDM | 0.511±0.060 | 0.496±0.061 | 0.363±0.082 | 0.449±0.067 | 0.229±0.122 | 0.284±0.102 | 0.499±0.061 | 0.404 | 0.272 | 0.125 |
| Rectified Flow | 0.519±0.049 | 0.473±0.054 | 0.302±0.081 | 0.433±0.058 | 0.153±0.143 | 0.269±0.090 | 0.455±0.056 | 0.372 | 0.277 | 0.108 |
| Score SDE | 0.573±0.061 | 0.519±0.067 | 0.370±0.092 | 0.486±0.071 | 0.259±0.126 | 0.330±0.102 | 0.530±0.066 | 0.438 | 0.268 | 0.189 |
| NVCode (Ours) | 0.616±0.049 | 0.614±0.050 | 0.436±0.070 | 0.523±0.058 | 0.341±0.090 | 0.468±0.065 | 0.585±0.052 | 0.512 | 0.268 | 0.043 |
Table 12d. Generator comparison on NeuroBOLT (Resting State).
| Generator | Cuneus | Heschl’s Gyrus | Middle Frontal | Precuneus | Putamen | Thalamus | Global Signal | Avg. R↑ | CRPS↓ | FC-MAE↓ |
| cGAN | 0.312 | 0.324 | 0.004 | 0.081 | 0.534 | 0.276 | 0.168 | 0.243 | 0.619 | 0.603 |
| Consistency | 0.353 | 0.286 | 0.364 | 0.437 | 0.284 | 0.348 | 0.177 | 0.321 | 0.605 | 0.382 |
| CVAE | 0.575 | 0.479 | 0.432 | 0.346 | 0.464 | 0.305 | 0.452 | 0.436 | 0.508 | 0.411 |
| DDPM | 0.523 | 0.365 | 0.334 | 0.379 | 0.532 | 0.252 | 0.339 | 0.389 | 0.480 | 0.432 |
| EDM | 0.533 | 0.515 | 0.376 | 0.411 | 0.472 | 0.336 | 0.382 | 0.432 | 0.479 | 0.402 |
| Rectified Flow | 0.480 | 0.458 | 0.299 | 0.362 | 0.543 | 0.339 | 0.325 | 0.401 | 0.483 | 0.395 |
| Score SDE | 0.548 | 0.586 | 0.467 | 0.250 | 0.394 | 0.340 | 0.433 | 0.431 | 0.489 | 0.431 |
| NVCode (Ours) | 0.707 | 0.495 | 0.291 | 0.461 | 0.608 | 0.328 | 0.536 | 0.489 | 0.432 | 0.361 |
| cGAN | 0.170 | -0.101 | -0.278 | -0.020 | 0.456 | 0.481 | -0.124 | 0.083 | 0.495 | 0.436 |
| Consistency | 0.006 | -0.046 | 0.128 | -0.131 | 0.188 | 0.241 | -0.122 | 0.061 | 0.577 | 0.425 |
| CVAE | 0.018 | -0.130 | -0.006 | 0.070 | 0.185 | 0.099 | -0.153 | 0.012 | 0.484 | 0.415 |
| DDPM | 0.537 | 0.157 | -0.181 | 0.189 | -0.315 | -0.101 | 0.139 | 0.061 | 0.484 | 0.258 |
| EDM | 0.168 | 0.058 | -0.164 | 0.043 | 0.303 | 0.292 | -0.078 | 0.089 | 0.476 | 0.374 |
| Rectified Flow | 0.129 | -0.160 | -0.020 | -0.049 | 0.352 | 0.261 | -0.197 | 0.045 | 0.487 | 0.443 |
| Score SDE | 0.251 | -0.088 | -0.163 | 0.131 | 0.190 | 0.148 | -0.122 | 0.049 | 0.475 | 0.337 |
| NVCode (Ours) | 0.654 | 0.660 | 0.342 | 0.588 | -0.012 | 0.182 | 0.660 | 0.439 | 0.466 | 0.310 |
Table 12e. Generator comparison on XP1 (Active).
| Generator | Cuneus | Heschl’s Gyrus | Middle Frontal | Precuneus | Putamen | Thalamus | Global Signal | Avg. R↑ | CRPS↓ | FC-MAE↓ |
| cGAN | 0.329±0.091 | 0.428±0.091 | 0.470±0.069 | 0.356±0.068 | 0.439±0.097 | 0.500±0.102 | 0.301±0.083 | 0.403 | 0.418 | 0.333 |
| Consistency | 0.301±0.091 | 0.437±0.095 | 0.447±0.065 | 0.366±0.077 | 0.426±0.073 | 0.385±0.088 | 0.364±0.075 | 0.389 | 0.445 | 0.303 |
| CVAE | 0.398±0.104 | 0.475±0.099 | 0.530±0.083 | 0.411±0.065 | 0.475±0.097 | 0.523±0.108 | 0.376±0.094 | 0.455 | 0.395 | 0.287 |
| DDPM | 0.336±0.100 | 0.440±0.076 | 0.448±0.096 | 0.370±0.068 | 0.441±0.065 | 0.458±0.088 | 0.350±0.084 | 0.406 | 0.363 | 0.273 |
| EDM | 0.390±0.089 | 0.426±0.080 | 0.515±0.084 | 0.388±0.046 | 0.436±0.077 | 0.482±0.114 | 0.349±0.079 | 0.427 | 0.374 | 0.261 |
| Rectified Flow | 0.388±0.080 | 0.399±0.090 | 0.479±0.075 | 0.382±0.083 | 0.449±0.075 | 0.492±0.092 | 0.350±0.076 | 0.420 | 0.377 | 0.265 |
| Score SDE | 0.357±0.089 | 0.490±0.099 | 0.532±0.092 | 0.395±0.062 | 0.470±0.090 | 0.497±0.104 | 0.402±0.082 | 0.449 | 0.364 | 0.245 |
| NVCode (Ours) | 0.405±0.084 | 0.542±0.100 | 0.496±0.113 | 0.442±0.069 | 0.491±0.099 | 0.543±0.120 | 0.381±0.121 | 0.471 | 0.395 | 0.226 |
| cGAN | 0.365±0.065 | 0.413±0.058 | 0.345±0.069 | 0.322±0.073 | 0.359±0.066 | 0.321±0.073 | 0.293±0.079 | 0.346 | 0.371 | 0.204 |
| Consistency | 0.384±0.070 | 0.474±0.058 | 0.429±0.064 | 0.412±0.066 | 0.331±0.081 | 0.366±0.074 | 0.349±0.077 | 0.392 | 0.405 | 0.178 |
| CVAE | 0.323±0.065 | 0.451±0.048 | 0.304±0.069 | 0.294±0.071 | 0.288±0.072 | 0.365±0.058 | 0.325±0.065 | 0.336 | 0.332 | 0.115 |
| DDPM | 0.326±0.074 | 0.461±0.054 | 0.456±0.055 | 0.413±0.060 | 0.311±0.078 | 0.354±0.069 | 0.287±0.083 | 0.373 | 0.336 | 0.137 |
| EDM | 0.351±0.078 | 0.457±0.061 | 0.448±0.062 | 0.485±0.064 | 0.371±0.074 | 0.290±0.092 | 0.394±0.070 | 0.392 | 0.335 | 0.158 |
| Rectified Flow | 0.333±0.056 | 0.351±0.053 | 0.263±0.069 | 0.269±0.067 | 0.242±0.074 | 0.278±0.065 | 0.263±0.068 | 0.285 | 0.345 | 0.136 |
| Score SDE | 0.301±0.073 | 0.456±0.050 | 0.327±0.068 | 0.278±0.048 | 0.242±0.088 | 0.304±0.072 | 0.321±0.069 | 0.318 | 0.336 | 0.147 |
| NVCode (Ours) | 0.406±0.094 | 0.366±0.130 | 0.494±0.059 | 0.451±0.072 | 0.266±0.187 | 0.331±0.194 | 0.394±0.108 | 0.386 | 0.351 | 0.167 |
Table 12f. Generator comparison on Affective Music (Active).
| Generator | Cuneus | Heschl’s Gyrus | Middle Frontal | Precuneus | Putamen | Thalamus | Global Signal | Avg. R↑ | CRPS↓ | FC-MAE↓ |
| cGAN | 0.264±0.073 | 0.377±0.090 | 0.286±0.081 | 0.304±0.086 | 0.332±0.089 | 0.334±0.088 | 0.375±0.087 | 0.325 | 0.464 | 0.502 |
| Consistency | 0.441±0.069 | 0.386±0.074 | 0.385±0.078 | 0.326±0.076 | 0.383±0.085 | 0.386±0.089 | 0.335±0.087 | 0.378 | 0.438 | 0.340 |
| CVAE | 0.327±0.088 | 0.420±0.093 | 0.362±0.088 | 0.314±0.093 | 0.403±0.080 | 0.379±0.102 | 0.351±0.092 | 0.365 | 0.370 | 0.347 |
| DDPM | 0.364±0.073 | 0.363±0.079 | 0.411±0.062 | 0.372±0.092 | 0.347±0.082 | 0.358±0.092 | 0.385±0.081 | 0.371 | 0.341 | 0.311 |
| EDM | 0.396±0.084 | 0.359±0.082 | 0.370±0.078 | 0.302±0.080 | 0.418±0.074 | 0.432±0.088 | 0.390±0.081 | 0.367 | 0.346 | 0.330 |
| Rectified Flow | 0.305±0.085 | 0.394±0.088 | 0.365±0.073 | 0.368±0.098 | 0.455±0.067 | 0.437±0.112 | 0.354±0.077 | 0.368 | 0.294 | 0.357 |
| Score SDE | 0.395±0.078 | 0.393±0.080 | 0.325±0.087 | 0.360±0.087 | 0.415±0.086 | 0.408±0.097 | 0.345±0.080 | 0.377 | 0.351 | 0.349 |
| NVCode (Ours) | 0.452±0.117 | 0.527±0.119 | 0.306±0.089 | 0.363±0.108 | 0.478±0.107 | 0.447±0.106 | 0.478±0.113 | 0.436 | 0.351 | 0.274 |
| cGAN | -0.071±0.085 | -0.046±0.110 | 0.012±0.180 | -0.074±0.083 | -0.021±0.153 | 0.022±0.151 | -0.009±0.192 | -0.027 | 0.345 | 0.214 |
| Consistency | -0.003±0.131 | -0.020±0.093 | -0.030±0.080 | -0.083±0.045 | 0.023±0.089 | -0.013±0.106 | -0.014±0.104 | -0.020 | 0.417 | 0.119 |
| CVAE | -0.017±0.122 | 0.009±0.142 | 0.016±0.125 | -0.043±0.084 | -0.007±0.148 | 0.046±0.081 | 0.015±0.126 | 0.003 | 0.328 | 0.220 |
| DDPM | 0.014±0.122 | 0.002±0.157 | -0.012±0.127 | -0.028±0.097 | -0.056±0.068 | -0.044±0.078 | 0.034±0.089 | -0.023 | 0.331 | 0.066 |
| EDM | -0.213±0.036 | 0.000±0.227 | 0.005±0.204 | -0.123±0.056 | 0.078±0.078 | -0.066±0.086 | 0.033±0.129 | -0.043 | 0.336 | 0.183 |
| Rectified Flow | -0.031±0.121 | -0.059±0.086 | -0.025±0.131 | -0.097±0.062 | -0.007±0.182 | 0.012±0.163 | -0.064±0.082 | -0.039 | 0.344 | 0.281 |
| Score SDE | -0.092±0.076 | -0.034±0.135 | -0.000±0.249 | -0.136±0.057 | 0.038±0.128 | 0.065±0.095 | 0.023±0.157 | -0.026 | 0.329 | 0.183 |
| NVCode (Ours) | 0.235±0.126 | 0.348±0.232 | 0.342±0.256 | 0.378±0.160 | 0.575±0.053 | 0.423±0.111 | 0.440±0.098 | 0.392 | 0.332 | 0.066 |
Table 12g. Generator comparison on Experience Sampling (Active).
| Generator | Primary Sensory | High level Cognitive | Subcortical | Global Signal | Avg. R↑ | CRPS↓ | FC-MAE↓ | |||
| Cuneus | Heschl’s Gyrus | Middle Frontal | Precuneus | Putamen | Thalamus | |||||
| Intra subject | ||||||||||
| cGAN | -0.445 | 0.004 | 0.089 | 0.240 | 0.222 | -0.207 | 0.387 | 0.041 | 0.441 | 0.760 |
| Consistency | -0.313 | -0.155 | 0.226 | 0.167 | 0.228 | 0.008 | 0.605 | 0.109 | 0.388 | 0.571 |
| CVAE | -0.300 | 0.279 | 0.360 | 0.672 | 0.502 | 0.216 | 0.674 | 0.343 | 0.323 | 0.502 |
| DDPM | -0.555 | -0.828 | 0.105 | -0.330 | -0.476 | -0.250 | 0.349 | -0.284 | 0.315 | 0.362 |
| EDM | -0.459 | -0.449 | -0.136 | -0.204 | 0.172 | 0.231 | 0.028 | -0.117 | 0.320 | 0.489 |
| Rectified Flow | -0.294 | -0.616 | -0.335 | 0.163 | -0.437 | -0.291 | -0.793 | -0.372 | 0.327 | 0.455 |
| Score SDE | -0.441 | -0.523 | 0.109 | 0.051 | 0.199 | -0.080 | -0.521 | -0.172 | 0.320 | 0.564 |
| NVCode (Ours) | 0.103 | 0.184 | 0.082 | 0.816 | 0.194 | 0.301 | 0.518 | 0.314 | 0.368 | 0.385 |
| Inter subject | ||||||||||
| cGAN | -0.638 | 0.474 | -0.580 | -0.325 | -0.339 | -0.646 | -0.112 | -0.309 | 0.409 | 0.687 |
| Consistency | 0.567 | -0.451 | 0.317 | 0.510 | 0.105 | 0.405 | 0.143 | 0.228 | 0.377 | 0.360 |
| CVAE | -0.097 | 0.261 | 0.641 | -0.015 | -0.050 | 0.151 | 0.628 | 0.217 | 0.305 | 0.315 |
| DDPM | 0.248 | -0.527 | -0.481 | -0.674 | -0.153 | -0.435 | -0.705 | -0.390 | 0.307 | 0.508 |
| EDM | -0.121 | 0.382 | 0.418 | -0.123 | 0.480 | -0.098 | 0.720 | 0.237 | 0.294 | 0.419 |
| Rectified Flow | -0.508 | 0.399 | -0.037 | -0.038 | 0.331 | 0.409 | 0.042 | 0.086 | 0.309 | 0.463 |
| Score SDE | -0.529 | 0.508 | 0.498 | 0.088 | 0.445 | 0.269 | 0.561 | 0.263 | 0.273 | 0.214 |
| NVCode (Ours) | 0.127 | 0.274 | 0.394 | -0.003 | 0.235 | 0.177 | 0.369 | 0.225 | 0.311 | 0.249 |
Table 12h. Generator comparison on NatView (Active).
Scan Level EEG–fMRI Evidence
Figure 8–Figure 14 show seven scans per target. Columns (a) and (b) show the EEG spectrogram and alpha scalp power (8–13 Hz) [10, 15]; (c) overlays the observed and predicted fMRI trajectories [88]. The purple guide marks acquisition in (d) and the end of the shaded input EEG window .
Figure 8. Cuneus examples. (a) EEG spectrogram; (b) alpha scalp power; (c) real fMRI (black dashed) and NVCode (red); (d) projected real, predicted and absolute-difference amplitudes.
Figure 14. Global signal examples. (a) EEG spectrogram; (b) alpha scalp power; (c) real fMRI (black dashed) and NVCode (purple); (d) whole-brain projections of real, predicted and absolute-difference amplitudes.
Snapshot amplitudes and normalization. Let be the target signal after forward and backward fifth-order Butterworth filtering at 0.15 Hz. The display scale is
Here counts source volumes, is the empirical 95th percentile, and . For denominator , zero is the filtered scan mean and one display unit equals filtered units. Trajectories and snapshots share this affine scale within a row. Benchmark scores use the split-specific scale in Section B.1.
Real, predicted, and absolute-difference values. At , the labels beneath the views give the observed amplitude, the mean of generated samples, and their absolute difference on this scale:
The filtered error is because the shared offset cancels. The same dimensionless error can represent different changes in filtered units across scans. Draw sets with the same mean yield identical point prediction panels regardless of spread.
Anatomical projection and shared color scale. Let be the display mask and its nonnegative weights, from a DiFuMo component for a region or anatomical intensity for the global signal. The peak-normalized weights are
Apply to both amplitudes and their absolute difference:
Because and , the projected error peaks at before rendering. Equal amplitudes give zero everywhere; opposite signs give the sum of their magnitudes.
Reading the spatial views. Anatomy supplies the spatial pattern in the plates and Figure 3(e); NVCode supplies one scalar per target and time. Regional displays use weight levels 0.1, 0.3, 0.5, 0.7, and 0.9 on transparent MNI152 anatomy; global surface colors average weights 2, 4, and 6 mm inward. The three views share geometry, orthographic view, shading, and opacity. Bars show 20 mm and colors span , with errors on the nonnegative half. Numbers give unprojected values; colors encode local weighted values. The footprint shows the mask and scale, not estimated voxelwise activation.
Figure 3. NVCode pipeline. (a) Non-overlapping patches and spectrograms describe each EEG window. (b) Target-specific encoders learn spatiotemporal and multiscale spectral features under fMRI supervision. (c) A projector combines the features into a neurovascular code. (d) The code conditions joint generation from Gaussian noise through a learned interpolant. (e) Time series and anatomical projections display the regional and global outputs.
Reading the trajectories. The guide compares amplitudes at one time; Pearson compares aligned fluctuations across the scan. For nonconstant observed and predicted amplitude vectors and , an additive shift or positive rescaling can change amplitudes while preserving correlation: for . Centering removes , and cancels between covariance and predicted standard deviation. A trace can track peaks and troughs but miss the guide, or match it without tracking the rest of the scan.
Figure 9. Heschl’s gyrus examples. (a) EEG spectrogram; (b) alpha scalp power; (c) real fMRI (black dashed) and NVCode (red); (d) projected real, predicted and absolute-difference amplitudes.
Figure 10. Middle frontal gyrus examples. (a) EEG spectrogram; (b) alpha scalp power; (c) real fMRI (black dashed) and NVCode (green); (d) projected real, predicted and absolute-difference amplitudes.
Figure 11. Precuneus examples. (a) EEG spectrogram; (b) alpha scalp power; (c) real fMRI (black dashed) and NVCode (green); (d) projected real, predicted and absolute-difference amplitudes.
Figure 12. Putamen examples. (a) EEG spectrogram; (b) alpha scalp power; (c) real fMRI (black dashed) and NVCode (blue); (d) projected real, predicted and absolute-difference amplitudes.
Figure 13. Thalamus examples. (a) EEG spectrogram; (b) alpha scalp power; (c) real fMRI (black dashed) and NVCode (blue); (d) projected real, predicted and absolute-difference amplitudes.
Experiment Details
This appendix specifies the data construction, baseline adaptation, metric formulas, downstream utility probe and ablation protocol used in § 4.
Experiment Setup: Data Preprocessing and Machine Requirements
Datasets and splits. Table 1 summarizes eight public simultaneous EEG–fMRI datasets ([33, 60]), comprising four resting-state ([7, 25]) and four task-evoked ([43, 60]) settings. Their source cohorts report 184 participants, while the 189 scans retained after scan-level exclusions yield 61,646 paired volumes. Each fMRI volume is paired with the immediately preceding 16-s EEG window, so future EEG does not enter the model input. Intra-subject evaluation uses 80% of volumes for training and 10% for validation. Test volumes follow a -volume buffer that separates them from validation and prevents overlap between their EEG contexts ([52]). Inter-subject evaluation ([54]) uses disjoint training and held-out subjects. Normalization statistics and checkpoint selection use only the training-subject partition.
Target signals, baselines and metrics. Each volume defines a seven-dimensional target vector containing six DiFuMo ROI signals and one global signal ([18, 59]). Figure 3(b) lists these targets: Cuneus, Heschl’s gyrus (H Gyrus), anterior middle frontal gyrus (MF Gyrus), anterior precuneus, putamen, thalamus, and the global signal. Every model predicts this same ordered vector from the same retained EEG–fMRI pairs and training-only normalization statistics. In Table 2, the generator architecture, sampler, target ordering, and split policy are held fixed while the EEG encoder configuration changes. In Table 3, the seven frozen NVCode encoders and fitted projector supply identical conditions while the downstream generation network changes. Stochastic generators return samples for each held-out EEG epoch. Avg. and FC-MAE evaluate the predictive mean, whereas mean marginal CRPS uses the complete empirical sample distribution. Dataset scores are first summarized over their internal splits and then macro-averaged with equal dataset weight. Appendix § 8.§ 2 gives the adaptation rules, metric definitions, and aggregation procedure.
Cohort and scan-count conventions. Table 1 distinguishes three levels of data accounting. Cohort Size counts participants in the original source cohorts. Scans counts runs retained after scan-level exclusions, and Pairs counts the volume-anchored EEG–fMRI observations from those runs before splitting. For NatView, the two retained runs provide 571 paired volumes. NatView contributes one dataset-level score to the benchmark mean, with the same weight as any other dataset.
Paired EEG to fMRI observations. Each observation pairs the fMRI volume acquired at with the preceding EEG interval . The recorded onset defines the alignment without an additional hemodynamic lag shift. The repetition time is dataset dependent: for XP1, Affective Music, MULTI-CLARID, gradCPT, and Experience Sampling, and for Sleep EEG–fMRI, NeuroBOLT, and NatView. The fixed window supplies preceding EEG context for estimating the BOLD response at each acquisition time ([52]).
EEG preprocessing and channel harmonization. EEG-informed fMRI analysis combines electrophysiological preprocessing with BOLD modeling ([1]) within broader multimodal brain imaging workflows ([11]). All EEG segments are resampled to 200 Hz with the polyphase finite impulse response resampler in mne.io.Raw.resample(..., method="polyphase"). The default anti aliasing low pass filter is applied at the Nyquist frequency and no time shift is introduced. Each segment is cropped to samples, and raw amplitudes are divided by 100 before being fed to the encoders. Native channel counts vary across datasets, so we harmonize all recordings to the following 26 channels of the 10–20 montage:
Non EEG channels such as ECG, EOG and EMG are removed, along with carbon wire loop sensors. Missing target channels are reconstructed by spherical spline interpolation against the standard 10–20 montage using MNE Python with standard_1020. Channels present in the source recording but outside the target set are discarded. Dataset provided referencing and artifact correction decisions are preserved. No dataset specific EEG augmentation is applied.
fMRI signal construction. For each 4D fMRI scan, we extract atlas level signals with nilearn’s NiftiMapsMasker using the 64 component DiFuMo atlas (Dadi et al., [18]) at 2 mm resolution. The masker is used only for soft mask spatial weighting; masker standardization and detrending are disabled so that all reported statistics are controlled by the split dependent preprocessing below. From the 64 DiFuMo components, we select six regional signals by label matching: Cuneus, Heschl’s gyrus, Middle Frontal Gyrus anterior, Precuneus anterior, Putamen and Thalamus. Under nilearn 0.10.3, these correspond to component IDs in the listed order. The seventh signal is the global signal (Murphy et al., [59]), computed as the unweighted mean over all 64 DiFuMo components before filtering or scaling. The seven signals are stacked into for scan and volume .
Temporal filtering. Target construction uses a fifth-order Butterworth low-pass filter for all seven fMRI signals. The filter is specified at each scan’s sampling rate with a cutoff in the low-frequency BOLD range ([16, 25]):
All methods use the same filtered fMRI targets in both evaluation protocols.
Normalization and split control. The per-dataset reconstruction comparisons use two normalizations. The first defines the robust-normalized fMRI label scale used for reported metrics. In the intra-subject protocol, a robust scaler is fitted for each scan and signal using only the corresponding temporal training portion:
In the inter subject protocol, the same definitions are evaluated over all volumes from training subjects in dataset , yielding and . These parameters remain fixed and are applied unchanged to every held out subject in dataset . Let for intra subject evaluation and for inter subject evaluation, where denotes the dataset containing scan . The robust-normalized label is
This fixed transformation defines the fMRI supervision and evaluation scale. The second normalization is the split specific generator score used inside the stochastic interpolant. In the intra subject protocol, the generator mean and standard deviation are fitted on the training rows of the scan. In the inter subject protocol, they are fitted only on training subjects. Generated samples are mapped back to the robust-normalized fMRI scale before metrics are computed.
Intra subject split. For a scan with fMRI volumes, we form four contiguous temporal portions in order: training volumes, validation volumes, a volume buffer and all remaining test volumes. The buffer keeps the test volumes and their 16 s EEG contexts separate from the earlier portions. We fit all trainable components on the training portion, select checkpoints on the validation portion and use the final portion for evaluation.
Inter subject split. Inter-subject evaluation groups recordings by subject and tests transfer to held-out people within each dataset. Both normalization layers, model fitting, checkpoint selection, and early stopping use the training-subject partition. Regional representation maps and feature caches are constructed within each training fold; evaluation applies these fixed maps to held-out EEG. The benchmark therefore measures subject transfer across eight simultaneous EEG–fMRI acquisition settings.
Reproducibility controls. The splits stay fixed across the three reconstruction runs, with seeds 42, 2026, and 114514. At the start of each run we set torch.manual_seed(r) and numpy.random.seed(r) for seed . All methods enable torch.use_deterministic_algorithms(True) and disable cuDNN benchmarking and TF32. Training uses fp32 without mixed precision or augmentation.
Machine requirements and software. All experiments were implemented in PyTorch and trained in parallel on four NVIDIA A100 80 GB or H100 80 GB GPUs. At inference time, the EEG derived context is computed once for each held out epoch and then shared across all velocity evaluations. With Euler steps and Monte Carlo samples, inference for a typical scan with 50 to 200 held out epochs uses one accelerator. The full eight dataset inter subject evaluation requires independent generator fits across subject splits and approximately 20 aggregate GPU days after caching per scan EEG features. The software environment uses PyTorch 2.1, SciPy 1.11, NumPy 1.26, MNE-Python , nilearn 0.10.3, linear attention transformer 0.19.1, umap-learn 0.5 (McInnes et al., [57]), CUDA 12.1 and cuDNN 8.9.
Main Experiment Details
The complete-model comparison in main-paper Table 4 and supplementary Table 9 pools training partitions across the eight datasets under each protocol and evaluates the same seven outputs. The component comparisons instead fit and evaluate separate models within each dataset.
| Method | Cuneus | Heschl’s Gyrus | Middle Frontal | Precuneus | Putamen | Thalamus | Avg. ↑ | CRPS↓ | FC-MAE↓ | |
| Intra NeuroBOLT | 0.418 | 0.392 | 0.405 | 0.436 | 0.477 | 0.439 | 0.514 | 0.440 | 0.400 | 0.323 |
| UnEBOLT | 0.436 | 0.493 | 0.472 | 0.476 | 0.435 | 0.503 | 0.509 | 0.475 | 0.361 | 0.287 |
| NVCode (Ours) | 0.473 | 0.482 | 0.510 | 0.536 | 0.498 | 0.475 | 0.528 | 0.500 | 0.247 | 0.210 |
| Inter NeuroBOLT | 0.316 | 0.324 | 0.260 | 0.247 | 0.281 | 0.317 | 0.369 | 0.302 | 0.473 | 0.385 |
| UnEBOLT | 0.304 | 0.382 | 0.419 | 0.475 | 0.436 | 0.420 | 0.383 | 0.403 | 0.384 | 0.262 |
| NVCode (Ours) | 0.294 | 0.436 | 0.381 | 0.495 | 0.487 | 0.461 | 0.463 | 0.431 | 0.316 | 0.172 |
Table 9. End-to-end EEG-to-fMRI comparison. Models train on all eight datasets pooled. Avg. weights all seven targets equally, CRPS scores the marginals, and FC-MAE compares predictive-mean connectivity.
Table 2 and Table 3 compare EEG encoder configurations and conditional generation configurations, respectively. The EEG encoder outputs the feature vector . The complete generator combines the conditional projector with the generation network , using for sampling randomness:
The protocols below specify which generator parameters are trained in each comparison. Table 7 compares eight configurations of target-specific encoding, joint output modeling, and stochastic interpolation.
EEG encoder baselines. Related EEG representation work uses convolutional feature extraction ([44]; [69]), recurrent sleep staging ([82]), and Transformer-based sleep staging ([68]). All encoder baselines are adapted to the same sequential EEG to fMRI prediction task. In Table 2, each baseline family uses one EEG encoder with a 1400-dimensional output representation. A temporary fMRI readout supervises this encoder with mean squared error on the seven robust-normalized target signals. Validation MSE selects the checkpoint, after which the temporary readout is discarded and the encoder is frozen. NVCode instead fits seven target-specific encoders, each with a temporary scalar head, and concatenates their 200-dimensional representations into the same 1400-dimensional interface. Each row fits a separate NVCode generator with the same architecture, jointly optimizing its projector and velocity field on the frozen encoder features. The projector maps the 1400 features to a context. In inter-subject evaluation, all fitting and validation selection occur within the training subjects of each split. The comparison fixes representation width, fMRI targets, split policy, normalization, generator architecture, sampler, and metrics while varying the EEG encoder configuration.
Encoder capacity. We compare one Shared encoder trained jointly on all targets with seven Regional encoders trained on separate targets (Table 13). We widen the Matched NVCode encoder to the regional parameter count. Each setup uses 1400 frozen features and a separately fitted NVCode generator.
| Encoder | Setup | Params (M) | Avg. ↑ | CRPS↓ | FC-MAE↓ |
| NVCode | Shared | 8.19 | 0.349 | 0.362 | 0.182 |
| NVCode | Matched | 55.35 | 0.373 | 0.317 | 0.195 |
| NVCode | Regional | 55.38 | 0.423 | 0.344 | 0.135 |
| SPaRCNet | Shared | 0.42 | 0.353 | 0.344 | 0.163 |
| SPaRCNet | Regional | 1.84 | 0.342 | 0.311 | 0.210 |
| NeuroBOLT | Shared | 8.19 | 0.340 | 0.410 | 0.238 |
| NeuroBOLT | Regional | 55.38 | 0.315 | 0.299 | 0.187 |
Table 13. Encoder capacity by supervision. Inter-subject scores give all eight datasets equal weight. Parameter counts exclude temporary heads and the generator.
With similar parameter counts, regional NVCode improves Avg. from 0.373 to 0.423 and lowers FC-MAE from 0.195 to 0.135.
Widening the shared encoder raises Avg. from 0.349 to 0.373, while the regional design retains the advantage seen in Table 7. The wide shared encoder attains lower marginal CRPS (0.317 versus 0.344). Regional SPaRCNet and NeuroBOLT also trade lower marginal CRPS for lower Avg. relative to their shared controls.
Generative model baselines. The baseline families build on adversarial learning [29], diffusion [75, 23], and score estimation [77], with conditional diffusion also supporting image translation [70]. For the cached-code comparison in Table 3 and its dataset breakdown, all rows use the same seven frozen NVCode encoders. We fit the projector with the NVCode velocity field, then freeze it when fitting the baseline generation networks. In this comparison, each complete generator has the form , with shared projector parameters and separately fitted network parameters . All rows use the same stored codes, z-scored labels and data splits. Each stochastic model returns samples per EEG epoch for the common evaluation metrics. The Rectified Flow control [51] shares the Gaussian source, linear probability path, and squared velocity objective with NVCode. The two procedures compare direct fitting to observed endpoints with one round of reflow. Let , where is the fixed EEG condition and is the normalized joint fMRI endpoint. Define
With and , the field optimum for a given projector is
Equation (14) expresses the field optimization within Eq. (6). NVCode learns the projector and field jointly, while the reported one-reflow baseline fits its initial field with a fixed projector. With the same architecture, initialization, optimizer and budget, a single fit without reflow jointly updates both modules exactly as NVCode does.
The Rectified Flow row in Table 3 and Tables 12a–12h denotes a specified one-reflow implementation. Its first field is fitted with Eq. (14). For each training condition , we draw and store one source , then integrate the first field from that same source to construct its paired model-induced endpoint
where is the numerical flow map. We store the paired bank without re-pairing sources and endpoints. A freshly initialized second field is fitted on straight segments from these stored pairs:
Thus, NVCode directly fits observed condition–endpoint pairs once, whereas the Rectified Flow control adds a teacher-generated endpoint bank, fresh second-stage initialization, and a one-reflow objective. In all result tables, “Rectified Flow” denotes this one-reflow implementation.
For the NVCode–Rectified Flow comparison, both rows use the same seven frozen regional encoders, the same 1400-dimensional concatenated representation and 512-dimensional context, the same seven-dimensional target ordering, training-only normalization statistics, subject or temporal split, Gaussian source law, time distribution, linear interpolation, vector-valued velocity-network parameterization, optimizer settings, and validation criterion. The same total optimization budget is used: NVCode applies it to one direct fit, while Rectified Flow divides it equally between the initial fit and the one-reflow fit. Final inference is also matched at Euler steps and sources per EEG epoch, after which both methods use the same inverse normalization and evaluation code. At inference, Rectified Flow uses no held-out fMRI to construct either the test condition or the sampled trajectory.
The comparison therefore contrasts direct fitting with the specified one-reflow procedure, including its extra field initialization and model-generated endpoints, under a fixed total optimization budget.
Generator-specific projectors. DDPM, EDM, and Score SDE use the same frozen EEG features in both settings. Frozen fits only the generation network, using codes from the fixed NVCode projector (Table 3). Own jointly fits the network and its own 512-dimensional projector using the generator’s training objective.
Table 5 reports held-out-subject scores under both projector training protocols.
Predictive mean Pearson correlation. Let stack the predictive means and observed targets for epochs in an evaluated scan or split. We average temporal Pearson correlations [66] over the fMRI signals:
where are the column means. Higher is better.
Mean marginal CRPS. The mean marginal continuous ranked probability score is computed per epoch from the Monte Carlo samples, averaged over fMRI signals and then averaged over the scan:
The bracketed term equals , where is the empirical distribution of . CRPS is a strictly proper scoring rule for each marginal predictive distribution [55, 28]. The reported average summarizes marginal probabilistic prediction quality across the seven targets. Lower is better. Equivalently, if is the empirical predictive distribution, then
This is the exact CRPS of the empirical predictive CDF. It follows by substituting independent draws from into the energy representation .
Functional connectivity error. Correlation-based functional networks summarize statistical associations among brain signals [6, 21, 94]. Let denote the th column of any matrix and be the Pearson correlation [66] between columns and . FC-MAE measures the mean absolute difference between matched off-diagonal entries in the predicted and observed matrices:
Here contains the -sample predictive mean for each EEG window. The metric matches off-diagonal entries of the predictive-mean and observed signal correlation matrices [86, 26]. It evaluates interregional organization across EEG windows through the resulting predictive-mean trajectories. Repeated samples for each fixed EEG condition enter this metric through their mean. Lower is better.
Lemma 1 (Affine properties of the reported metrics). Let with for every signal. Applying to both predictions and targets leaves every per-signal Pearson correlation and the FC-MAE unchanged. For the -th signal,
Proof. For any temporal vector , . The positive scale cancels between the covariance numerator and standard-deviation denominator of Pearson correlation. The same cancellation holds independently for both columns of every functional-connectivity entry. Therefore, the complete correlation matrices and their elementwise differences are unchanged. For CRPS, both absolute differences in the energy representation acquire the common factor , which proves Eq. (18).
Lemma 1 explains why inverse generator normalization preserves the temporal and cross-regional correlation diagnostics exactly. It also restores the signalwise scale on which marginal CRPS is aggregated and reported.
Aggregation. Within each seed run, reconstruction metrics are computed per held out temporal segment in the intra-subject protocol and per held out subject split in the inter-subject protocol. If denotes a metric for split of dataset in that run, its dataset and benchmark summaries are
This two-level macro average gives each dataset equal weight after its internal splits are summarized. Reported reconstruction means average these summaries over the three seed runs. For each dataset, method, evaluation setting, and target signal, we first aggregate correlation scores over the splits within each run. The standard deviations in Appendix A summarize variation across three training seeds on those fixed splits. The sampled response vectors enter the predictive-mean and marginal-score calculations within each split.
Sensitivity to excluding NatView. Reweighting the seven remaining datasets in Tables 11a–11g and 12a–12g preserved NVCode’s lead in both protocols. In Intra, NVCode reached Avg. , compared with SIREN-based (0.434) and EDM (0.418), the strongest remaining encoder and generator alternatives. In Inter, it reached 0.451, compared with SPaRCNet (0.394) and EDM (0.292). Each of the seven datasets contributes equally, using the original fitted models.
Downstream Utility Details
We use subject identification to evaluate synthetic fMRI in two roles: as a test input for a classifier trained on real fMRI and as training data for a classifier tested on real fMRI.
TrainReal TestSynth protocol. For each dataset, we train a subject identification classifier on real robust-normalized fMRI vectors from the real fMRI training temporal segments and validate it on real validation segments. The subject label space is fixed within the dataset. Classifier fitting, validation, and checkpoint selection use exclusively real fMRI data. After selection, the classifier is frozen. The real test row in Table 6 and 15 evaluates this classifier on held out real fMRI. A synthetic row evaluates the same classifier on generated fMRI from matched held out EEG epochs. Thus, measures test-input utility through the change in subject-identification accuracy. Both test conditions use the same frozen classifier fitted on the same training data.
Classifier architecture and optimization. The classifier is a lightweight two layer network:
Here is the number of subject labels in the dataset and LayerNorm follows Ba et al. [4]. We use cross entropy, AdamW (Kingma and Ba, [38]; Loshchilov and Hutter, [53]), learning rate , weight decay , and batch size 256. Early stopping monitors accuracy on the corresponding validation inputs with patience 20 epochs.
Utility score. For each dataset and synthetic method, we report
A higher means that the frozen classifier attains higher identity accuracy on synthetic fMRI. The headline weights each dataset equally. Tables report gains to three decimal places; multiplying an unrounded gain by 100 expresses it in percentage points. This score complements reconstruction metrics by measuring classifier-accessible identity structure under the shift from real training inputs to synthetic test inputs.
Synthetic training. For each dataset, we train separate classifiers on DDPM or NVCode predictions from matched training EEG and select checkpoints on synthetic validation inputs. The architecture, optimization, temporal splits, and identity labels stay fixed. All classifiers, including the real-trained reference, are tested on the same held-out real fMRI epochs.
NVCode improves accuracy on all eight datasets, compared with five for DDPM. Table 14 reports equally weighted mean gains of 1.38 and 0.54 percentage points, respectively. On NatView, NVCode gains 1.9 points while DDPM loses 1.4 on the same real test inputs.
With the test inputs held fixed, the gains show that a classifier can learn identity cues from synthetic NVCode outputs and use them when identifying participants from measured fMRI.
Ablation Study Details
Table 15 compares the complete and single-encoder representation sets under TrainReal TestSynth. Main-paper Table 7 shows how encoder and output designs affect reconstruction on held-out subjects.
| Encoder | Dataset accuracy / | Sleep EEG–fMRI | MULTI-CLARID | gradCPT | NeuroBOLT | XP1 | Affective Music | NatView | Experience Sampling | Mean |
| Real test | 0.861 | 0.787 | 0.746 | 0.869 | 0.874 | 0.782 | 0.747 | 0.702 | 0.796 | |
| Cuneus only | +0.004 | <u>+0.016</u> | +0.018 | +0.000 | -0.011 | -0.001 | +0.007 | -0.001 | +0.004 | |
| Heschl’s only | -0.013 | -0.017 | +0.021 | -0.022 | +0.002 | -0.001 | -0.081 | -0.010 | -0.015 | |
| Mid. Frontal only | +0.006 | -0.015 | -0.018 | -0.002 | -0.006 | +0.001 | -0.016 | -0.004 | -0.007 | |
| Precuneus only | +0.022 | +0.008 | <u>+0.033</u> | -0.003 | +0.040 | <u>+0.021</u> | <u>+0.008</u> | +0.014 | <u>+0.018</u> | |
| Putamen only | -0.016 | -0.015 | -0.024 | -0.019 | +0.005 | -0.024 | -0.082 | -0.036 | -0.026 | |
| Thalamus only | -0.018 | -0.009 | -0.025 | -0.041 | -0.054 | -0.034 | -0.074 | +0.002 | -0.032 | |
| Global Signal only | <u>+0.024</u> | +0.003 | -0.006 | <u>+0.003</u> | <u>+0.036</u> | <u>+0.021</u> | -0.001 | <u>+0.021</u> | +0.013 | |
| NVCode (Ours) | +0.028 | +0.027 | +0.036 | +0.043 | +0.019 | +0.031 | +0.045 | <u>+0.020</u> | +0.031 |
Table 15. Full regional aggregation provides the strongest downstream transfer. The encoder set supplied to the projector varies. Generator capacity, sampler, training protocol, and the real-trained classifier are held constant. Best values are darker purple, bold; second-best values are <u>light purple, underlined</u>.
Single-signal regional-encoder ablation
All variants use the same sampler and fMRI output space. Downstream evaluation uses the same classifier and metric for every representation set.
Single-signal representation variants. Each alternative retains the Cuneus, Heschl’s, Middle Frontal, Precuneus, Putamen, Thalamus, or Global Signal representation map. The retained map enters the same type of learned projector, preserving condition dimensionality. Each representation set uses the same generator training procedure and capacity.
Results and interpretation. Full NVCode achieves the highest mean utility lift, , compared with for Precuneus only and for Global Signal only. Its gains reach on NatView, on NeuroBOLT, and on gradCPT, with positive gains on all eight datasets. The full NVCode row in Table 15 reproduces the downstream utility scores in main-paper Table 6.
Controlled joint-output and stochastic-interpolant ablation
Table 7 compares two EEG encoder configurations with four output designs under inter-subject evaluation. The seven controls below follow the row order in the table; the eighth row is the full NVCode reference.
Shared experimental base. All eight configurations use the retained EEG–fMRI pairs, robust-normalized targets, subject-disjoint splits, and target ordering for the eight datasets in Table 1. The validation-selected
EEG encoder checkpoints are reused across output designs and remain frozen. Whenever a control includes a second stage, it fits a separate two-layer projector with (Appendix § 9.§ 3) together with its output module. The trainable parameter count differs by at most 1% between output modules designed to match capacity.
Deterministic Joint Regression
The input is the concatenated -dimensional representation from the seven frozen regional encoders; their temporary scalar heads are discarded. A new projector and one joint MLP that predicts all seven targets are trained together:
The MLP follows the hidden-width sequence of the NVCode velocity network without state and time inputs, with widths adjusted for parameter matching. It predicts one response vector per EEG epoch, without a velocity field or sampling.
Independent Interpolants
The input is the same concatenated regional representation, and the seven temporary scalar heads are again discarded. We train a new projector and seven scalar conditional velocity fields. Each target has its own independent Gaussian source and interpolant:
Each scalar field is trained to match and generates with . A field receives only its own evolving coordinate together with the shared EEG condition; the seven fields therefore have no cross-coordinate state access. Their total parameter count is matched to the joint NVCode field. The control returns samples obtained with Euler steps.
NVCode w/ Shared Encoder
The input is the 1400-dimensional representation from one frozen encoder supervised jointly on all seven targets. Its temporary seven-output linear head is discarded. We fit a new projector and one conditional velocity field that receives the complete evolving seven-signal vector. Each EEG epoch uses samples with Euler steps per sample.
First-Stage Linear Heads
Each EEG epoch is passed through the seven validation-selected regional encoder–head pairs. The seven retained scalar heads produce one target each, and their outputs are concatenated in the fixed target order. For each EEG epoch, the retained head directly returns one point prediction without an additional projector, regressor, or velocity field.
Shared Indep. Interpolants
The input is the frozen shared encoder representation used in Sec. B.4.2.c, and its temporary seven-output head is discarded. A new projector and seven scalar conditional velocity fields are trained as in Sec. B.4.2.b, so each field observes only its own evolving coordinate and the common condition. Sampling uses Euler steps for each of the draws.
B.4.2.f Shared Joint Regression. The input is the same frozen shared encoder representation, with its temporary seven-output head discarded. A new projector and one joint seven-output MLP are trained with the loss above. This control has no velocity field or stochastic sampling and returns one point prediction per EEG epoch.
B.4.2.g Shared Linear Heads. For each EEG epoch, the retained linear head reads the 1400 features of the validation-selected shared encoder. Its seven outputs form one point prediction for each of the seven fMRI signals.
Full NVCode reference. Full NVCode takes the concatenated representations from the seven frozen regional encoders and discards their temporary scalar heads. It trains a new projector and one joint seven-dimensional conditional velocity field as specified in § 3.2–§ 3.5. The field receives the complete evolving target vector. For each EEG epoch, Euler steps integrate the field from each of the independent Gaussian draws.
Evaluation and aggregation. Stochastic variants return samples per held-out EEG epoch, while deterministic variants return one point prediction. Avg. and FC-MAE are computed from the predictive mean using the definitions in Appendix § 8.§ 2. For a deterministic prediction, CRPS is evaluated as the point-mass score , which places all rows on the same lower-is-better scale. We summarize the metrics for each held-out subject split and then weight the datasets equally, following Eq. (19).
Regional representations. Across the four output designs, regional encoders improve Avg. over their shared counterparts. The gains are 0.122 for linear heads, 0.112 for joint regression, 0.129 for independent interpolants, and 0.074 for joint interpolation. FC-MAE also decreases in all four comparisons. The regional linear heads alone reach Avg. , CRPS , and FC-MAE .
Output design. With either encoder configuration, joint interpolation yields higher Avg. and lower FC-MAE than independent interpolation or deterministic joint regression. With the shared encoder, joint interpolation reaches 0.349 Avg. and 0.182 FC-MAE, compared with 0.276 and 0.266 for independent interpolation. Full NVCode attains the lowest marginal CRPS (0.344), followed by shared joint regression (0.357). It also achieves the highest Avg. and lowest FC-MAE across all eight configurations.
Joint Sample Evaluation
We score the seven-signal samples for each held-out EEG window on the robust-normalized fMRI scale. NVCode and Independent Interpolants use the same frozen regional encoders and test windows. The shuffled control permutes each signal’s draws within the window, preserving its empirical distribution and mean.
Table 8 reports the energy score, variogram score and joint coverage for the three configurations.
Multivariate scores. For observed vector and samples , the energy score (ES) uses Euclidean distances (Gneiting and Raftery, [28]):
The variogram score (VS) averages the squared discrepancies in square-root absolute differences over the 21 unordered signal pairs (Scheuerer and Hamill, [71]):
Joint coverage. For each window, the first 31 samples give a mean and sample standard deviation for each signal, with floored at . For each of the remaining 19 draws, we compute . The 18th smallest deviation sets the radius . We count the observed vector as covered when , i.e., all seven observed values fall within their bounds. If the observed and reference deviations are exchangeable without ties, this rule covers 18 of 20 possible ranks. We summarize scores within held-out subjects and weight the eight datasets equally.
Method Details
NVCode connects target-supervised EEG representation learning to joint fMRI generation through a shared neurovascular code. This appendix specifies that representation-to-generation pathway and derives its conditional velocity-matching foundation [50, 2]. Appendix § 8.§ 4 reports how the encoder and output designs affect prediction.
Velocity Matching Identity
This section specializes the conditional velocity-matching identity [50, 2] to a fixed neurovascular code map. On a probability space , let be a paired EEG input and normalized fMRI endpoint, and set . Draw independently of and independently of . Define
Assume , so the conditional velocities below are square integrable.
Conditional projection. Let and define .
Proposition 1 (Optimal conditional velocity). For a fixed conditioning map , the minimizer of the population squared velocity-matching risk over square-integrable measurable fields is
Lemma 2 (Orthogonal risk decomposition). For every square integrable -measurable vector ,
Thus the unique minimizer equals almost surely.
Proof. Expanding around gives
Applying the tower property to the -measurable gives a zero cross term:
The remaining excess-risk term is nonnegative and vanishes precisely when almost surely.
With , Lemma 2 proves Proposition 1 and yields
The excess risk is therefore the squared field error averaged over the conditional interpolation path.
Conditional continuity equation. The optimal field induces the following continuity equation for the conditional density along the interpolation path.
Theorem 1 (Conditional probability-path identity). Fix a condition . Suppose the conditional law of has a differentiable density , and differentiation may pass through the conditional expectation. Then satisfies
in the weak sense.
Proof. Let be a smooth compactly supported test function. Since ,
The tower property gives the third line. Because has compact support, the boundary term vanishes when integrating by parts to obtain Eq. (26).
Empirical transport diagnostic. Figure 15 displays eleven states along the numerically integrated trajectory of a held-out scan, from to in steps of 0.1. Correlation rises from source to endpoint. Real and generated samples overlap in UMAP space at the endpoint.
Figure 15. EEG-conditioned transport on a held-out scan. Top: projected states from the Gaussian source at to the generated endpoint at . Bottom left: real and generated endpoints overlap in UMAP space. Bottom right: target correlation rises along the integrated trajectory.
Proposition 2 (Conditional endpoint transport). Assume the ODE
has a unique solution map and Eq. (26) has a unique probability-density solution. Then
Proof. The ODE pushforward and the interpolant density from Theorem 1 solve the same continuity equation. Independence of and gives both paths the initial law . Uniqueness identifies the paths, and at gives the endpoint law.
Proposition 2 identifies the endpoint law represented by a fixed code. If the code is conditionally sufficient, the transported endpoint law also equals the law conditional on the original EEG input:
These identities hold for the population-optimal field under the stated regularity and uniqueness assumptions. NVCode fits a neural approximation to this field using target-supervised codes and the velocity objective in Eq. (6).
Together, Lemma 2, Theorem 1, and Proposition 2 connect conditional velocity regression to transport of the joint fMRI endpoint law.
Regional EEG Evidence Encoders
NVCode learns a target-specific EEG representation with each encoder in Eq. (2). Each encoder combines a spatiotemporal branch with a multi-scale spectral branch. The encoders have independent parameters. Each produces one EEG feature vector under supervision from its corresponding fMRI target.
EEG representation learning also uses masked segment reconstruction ([17]) and geometry-aware pretraining across electrode layouts ((Yi et al., 2023)). Here, the regional prediction objectives define the supervision for the temporal and spectral features specified below.
Spatiotemporal branch. Patching provides a tokenized interface for time-series representation learning ([62]). The EEG window is divided into non-overlapping patches of samples per channel. A convolutional patcher , channel embedding , and temporal embedding define the token at channel and patch :
The resulting sequence retains each patch’s channel–time identity.
A learnable [CLS] token ([22]) is inserted to support global attention exchange during the Transformer update. The sequence is processed by a pre-norm Transformer with depth 12, hidden dimension , 10 attention heads, MLP expansion ratio 4, qkv bias enabled, stochastic depth rate 0.1, and layer-scale initialization 0.1. If denotes this Transformer and selects a contextualized EEG token, the branch output is
The [CLS] token participates in attention, while the branch output averages the contextualized EEG tokens.
Multi-scale spectral branch. For each channel, the spectral branch computes Short-Time Fourier Transform magnitudes at four FFT lengths:
With a hop length of , scale has non-overlapping windows and frequency bins:
Learned projections align every scale to the same frequency and temporal dimensions. For a channel slice , use and to obtain
The four aligned tensors are summed before tokenization. For aligned temporal coordinate , define
A four-layer linear-attention Transformer processes the stacked sequence . We average its contextualized tokens across channels and windows:
Equation (33) combines the four spectral resolutions in a fixed -token sequence.
Representation output. The final regional EEG representation combines the temporal and spectral branches:
The resulting feature vector carries both branches into the generator’s shared conditioning module after its temporary scalar head is discarded.
Shared Conditioning Module
The shared conditioning module is the input component of the complete generator. We flatten the arrangement in Eq. (3) by stacking the target vectors in order, so for the matrix products below. The projector maps features to a neurovascular code through two layers:
Here , , and . We use the default PyTorch initialization for the weights and biases of both linear layers.
The first projection makes regional encoder aggregation explicit. Partition , where . Then
Thus, every first-layer coordinate can aggregate target-supervised evidence from all seven encoders. Figure 16 schematically illustrates the 512-position layout. Each regional objective trains an EEG feature map; the generation objective trains how their hidden features are combined. For each EEG window, the resulting code is shared by all seven outputs throughout sampling.
Figure 16. Shared EEG condition. The code positions form an matrix. Entries are deterministic illustrations; red, white, and blue denote negative, near-zero, and positive values, respectively.
Source-conditioned synthesis also appears in MRI contrast translation ([20, 65]) and visual reconstruction from measured fMRI ([83, 73]). In NVCode, the source is the EEG window: carries its target-supervised features into the velocity network within the complete generator.
Field Parameterization
The velocity field combines the current seven-signal state , interpolation time , and shared EEG code . Both the state mixer and the subsequent MLP are parameterized by :
The state mixer exposes a learned combination of the current fMRI coordinates to each output velocity.
The time value is encoded by a sinusoidal embedding with . For ,
The velocity field is then
The state mixer gives each output velocity access to the full evolving state. By contrast, each scalar field in the factorized-interpolant ablation sees its own coordinate and the common EEG code (Appendix § 8.§ 4).
Writing for the Jacobian of the MLP output with respect to its state-input block gives
The learned factors permit cross-coordinate responses within each joint velocity evaluation. Shared conditioning supplies the EEG evidence, while access to the evolving joint state supplies the cross-target interactions tested by the independent-interpolant control. The MLP has widths , with . Its module sequence is:
Linear, followed by LayerNorm and SiLU;
Linear, followed by LayerNorm and SiLU;
Linear, followed by SiLU;
Linear, with no activation.
All linear layers, including the output layer, use biases and PyTorch default Kaiming uniform initialization.
Optimization Details
NVCode first optimizes the regional representation objectives, then trains its complete generator by fitting the projector and joint field with the selected encoders fixed. The two training objectives are
Each regional encoder and its temporary scalar head are fitted independently with AdamW. Minimum validation MSE selects the checkpoint ; its head is discarded and the encoder is frozen for generation.
With the selected encoders fixed, AdamW and OneCycleLR jointly optimize and . Training-only statistics define each endpoint , and each example receives independently sampled and . Table 16 gives the split-specific epoch and stopping settings. A single validation checkpoint selects the projector and field together.
Table 16 NVCode hyperparameters. Network dimensions and fitting settings are listed for the regional encoders and joint interpolant, followed by the Euler steps and the sample counts for validation and testing.
| Hyperparameter | Value |
| Regional representation dimension | 200 |
| Spatiotemporal patch length / patches | |
| Representation Transformer depth / heads / MLP ratio | 12 / 10 / 4 |
| Spectral branch FFT lengths | |
| Spectral branch temporal projection size | 32 |
| Shared context dimension | 512 |
| Velocity MLP hidden width / time embedding | 512 / 32 |
| Representation fitting optimizer | AdamW |
| Representation fitting learning rate / weight decay / batch / epochs | / 0.05 / 64 / 100 |
| Interpolant fitting optimizer | AdamW + OneCycleLR |
| Interpolant fitting peak learning rate / weight decay / batch | / / 128 |
| Interpolant fitting max epochs / early stopping | 300 / 30 for within subject; fixed 300 for cross subject |
| Gradient norm clip / precision | 1.0 / fp32 |
| Random seeds | 42 / 2026 / 114514 |
| Euler steps / step size | 100 / |
| Monte Carlo samples | 50 test / 10 validation |
Table 16.
In the encoder comparison, each configuration supplies 1400 frozen features to a separately fitted projector and velocity field of the same architecture. In the cached-code generator comparison, NVCode retains its selected projector–field pair, and each baseline fits its network using that projector’s frozen outputs. Table 5 separately compares this setup with fitting each baseline’s own projector and network jointly. Both projector settings use the same frozen EEG features, as detailed in Appendix § 8.§ 2.
Generation Details
For each evaluation EEG window, NVCode computes the shared code once and draws independent Gaussian source vectors. With and , left-endpoint Euler integration updates all seven signals jointly:
Here follows the learned field, while in Eq. (4) defines its training path. We use steps and source draws per test window.
Proposition 3 (Sampling-error decomposition). Fix a condition and write . Assume is -Lipschitz in , uniformly over , and the exact learned-field trajectory satisfies . Let be the population ODE trajectory from Eq. (28), initialized from the same source sample. Then the -step Euler endpoint obeys
with the first term interpreted as when .
Proof. Let , , and . Taylor’s theorem and the derivative bound give a local remainder of at most . Lipschitz continuity then yields
Summing the geometric recursion gives
Next set and . The integral forms of the two ODEs imply
Grönwall’s inequality gives . The triangle inequality combines this field-approximation term with Eq. (41), proving Eq. (39). □
Under these assumptions, Proposition 3 separates the Euler discretization term from the trajectory-integrated field-approximation error.
Each terminal state is mapped to the robust-normalized fMRI supervision scale by reversing the generator z-score:
For one EEG window, the -sample predictive mean is
With independent sources, the average is unbiased for the mean of the finite- sampler. Its covariance scales inversely with the number of draws :
Equation (43) follows from linearity of expectation and independence of the source draws.
Error in the predictive mean. For a fixed EEG window with code , take the population conditional mean as the reference on the supervision scale. Write . The conditional squared error relative to this reference is
Expanding around makes the cross term vanish by Eq. (43). At fixed , increasing reduces the Monte Carlo variance without changing the finite-step sampler mean. Increasing instead reduces the Euler discretization bound in Proposition 3 without changing the learned field. The identity concerns the mean at one EEG window, not agreement of the full joint distributions.
For EEG windows, the sample tensor is and the stacked means form . Each window receives independent Gaussian sources, while its seven outputs evolve jointly. Temporal correspondence and interregional organization are evaluated across windows using through Pearson correlation and predictive-mean FC-MAE. Mean marginal CRPS evaluates the per-target sample distributions. These summaries separate same-window generation from the temporal structure of the predictive means.
References
- [1]Rodolfo Abreu, Alberto Leal, and Patricia Figueiredo. Eeg-informed fmri: a review of data analysis methods. Frontiers in human neuroscience, 12:29, 2018.DOI
- [2]Michael Albergo, Nicholas M Boffi, and Eric Vanden-Eijnden. Stochastic interpolants: A unifying framework for flows and diffusions. Journal of Machine Learning Research, 26(209):1–80, 2025.
- [3]Philip J Allen, Oliver Josephs, and Robert Turner. A method for removing imaging artifact from continuous eeg recorded during functional mri. Neuroimage, 12(2):230–239, 2000.pubmed.ncbi.nlm.nih.gov/10913328
- [4]Jimmy Lei Ba, Jamie Ryan Kiros, and Geoffrey E Hinton. Layer normalization. arXiv preprint arXiv:1607.06450, 2016.arxiv.org/abs/1607.06450
- [5]Hubert Banville, Omar Chehab, Aapo Hyvärinen, Denis-Alexander Engemann, and Alexandre Gramfort. Uncovering the structure of clinical eeg signals with self-supervised learning. Journal of Neural Engineering, 18(4):046020, 2021.DOI
- [6]Danielle S Bassett and Olaf Sporns. Network neuroscience. Nature neuroscience, 20(3):353–364, 2017.DOI
- [7]Bharat Biswal, F Zerrin Yetkin, Victor M Haughton, and James S Hyde. Functional connectivity in the motor cortex of resting human brain using echo-planar mri. Magnetic resonance in medicine, 34(4):537–541, 1995.pubmed.ncbi.nlm.nih.gov/8524021
- [8]Rishi Bommasani, Drew A Hudson, Ehsan Adeli, Russ Altman, Simran Arora, Sydney von Arx, Michael S Bernstein, Jeannette Bohg, Antoine Bosselut, Emma Brunskill, et al. On the opportunities and risks of foundation models. arXiv preprint arXiv:2108.07258, 2021.arxiv.org/abs/2108.07258
- [9]Madeleine Bullock, Graeme D Jackson, and David F Abbott. Artifact reduction in simultaneous eeg-fmri: a systematic review of methods and contemporary usage. Frontiers in neurology, 12:622719, 2021.DOI
- [10]György Buzsáki and Brendon O Watson. Brain rhythms and neural syntax: implications for efficient coding of cognitive content and neuropsychiatric disease. Dialogues in clinical neuroscience, 14(4):345–367, 2012.pubmed.ncbi.nlm.nih.gov/23393413
- [11]Vince D Calhoun and Jing Sui. Multimodal fusion of brain imaging data: a key to finding the missing link (s) in complex mental illness. Biological psychiatry: cognitive neuroscience and neuroimaging, 1(3):230–244, 2016.pubmed.ncbi.nlm.nih.gov/27347565
- [12]Josue Ortega Caro, Antonio H de O Fonseca, Christopher Averill, Syed A Rizvi, Matteo Rosati, James L Cross, Prateek Mittal, Emanuele Zappala, Daniel Levine, Rahul M Dhodapkar, et al. Brainm: A foundation model for brain activity recordings. BioRxiv, pages 2023–09, 2023.DOI
- [13]Younghwa Cha, Yeji Lee, Eunhee Ji, SoHyun Han, Sunhyun Min, Hyoungkyu Kim, Minseo Cho, Hae Seong Lee, Youngjai Park, and Joon-Young Moon. "sustained attention task (gradcpt) dataset using simultaneous eeg-fmri and dti", 2026.DOI
- [14]Ricky TQ Chen, Yulia Rubanova, Jesse Bettencourt, and David K Duvenaud. Neural ordinary differential equations. Advances in neural information processing systems, 31, 2018.arxiv.org/abs/1806.07366
- [15]Michael X Cohen. Where does eeg come from and what does it mean? Trends in neurosciences, 40(4):208–218, 2017.DOI
- [16]Dietmar Cordes, Victor M Haughton, Konstantinos Arfanakis, John D Carew, Patrick A Turski, Chad H Moritz, Michelle A Quigley, and M Elizabeth Meyerand. Frequencies contributing to functional connectivity in the cerebral cortex in “resting-state” data. American journal of neuroradiology, 22(7):1326–1333, 2001.pubmed.ncbi.nlm.nih.gov/11498421
- [17]Wenhui Cui, Woojae Jeong, Philipp Thölke, Takfarinas Medani, Karim Jerbi, Anand A Joshi, and Richard M Leahy. Neuro-gpt: Towards a foundation model for eeg. In 2024 IEEE International Symposium on Biomedical Imaging (ISBI), pages 1–5. IEEE, 2024.arxiv.org/abs/2311.03764
- [18]Kamalaker Dadi, Gaël Varoquaux, Antonia Machlouzarides-Shalit, Krzysztof J Gorgolewski, Demian Wassermann, Bertrand Thirion, and Arthur Mensch. Fine-grain atlases of functional modes for fmri analysis. NeuroImage, 221:117126, 2020.arxiv.org/abs/2003.05405
- [19]Ian Daly, Nicoletta Nicolaou, Duncan Williams, Faustina Hwang, Alexis Kirke, Eduardo Miranda, and Slawomir J. Nasuto. "a dataset recording joint eeg-fmri during affective music listening ", 2020.
- [20]Salman UH Dar, Mahmut Yurt, Levent Karacan, Aykut Erdem, Erkut Erdem, and Tolga Çukur. Image synthesis in multi-contrast mri with conditional generative adversarial networks. IEEE transactions on medical imaging, 38 (10):2375–2388, 2019.
- [21]Fani Deligianni, Maria Centeno, David W Carmichael, and Jonathan D Clayden. Relating resting-state fmri and eeg whole-brain connectomes across frequency bands. Frontiers in neuroscience, 8:258, 2014.DOI
- [22]Jacob Devlin, Ming-Wei Chang, Kenton Lee, and Kristina Toutanova. Bert: Pre-training of deep bidirectional transformers for language understanding. In Proceedings of the 2019 conference of the North American chapter of the association for computational linguistics: human language technologies, volume 1 (long and short papers), pages 4171–4186, 2019.arxiv.org/abs/1810.04805
- [23]Prafulla Dhariwal and Alexander Nichol. Diffusion models beat gans on image synthesis. Advances in neural information processing systems, 34:8780–8794, 2021.
- [24]Alexey Dosovitskiy, Lucas Beyer, Alexander Kolesnikov, Dirk Weissenborn, Xiaohua Zhai, Thomas Unterthiner, Mostafa Dehghani, Matthias Minderer, Georg Heigold, Sylvain Gelly, et al. An image is worth 16x16 words: Transformers for image recognition at scale. arXiv preprint arXiv:2010.11929, 2020.arxiv.org/abs/2010.11929
- [25]Michael D Fox and Marcus E Raichle. Spontaneous fluctuations in brain activity observed with functional magnetic resonance imaging. Nature reviews neuroscience, 8(9):700–711, 2007.pubmed.ncbi.nlm.nih.gov/17704812
- [26]Karl J Friston. Functional and effective connectivity: a review. Brain connectivity, 1(1):13–36, 2011.DOI
- [27]Matthew F Glasser, Timothy S Coalson, Emma C Robinson, Carl D Hacker, John Harwell, Essa Yacoub, Kamil Ugurbil, Jesper Andersson, Christian F Beckmann, Mark Jenkinson, et al. A multi-modal parcellation of human cerebral cortex. Nature, 536(7617):171–178, 2016.DOI
- [28]Tilmann Gneiting and Adrian E Raftery. Strictly proper scoring rules, prediction, and estimation. Journal of the American statistical Association, 102(477):359–378, 2007.
- [29]Ian J Goodfellow, Jean Pouget-Abadie, Mehdi Mirza, Bing Xu, David Warde-Farley, Sherjil Ozair, Aaron Courville, and Yoshua Bengio. Generative adversarial nets. Advances in neural information processing systems, 27, 2014.
- [30]Will Grathwohl, Ricky TQ Chen, Jesse Bettencourt, Ilya Sutskever, and David Duvenaud. Ffjord: Free-form continuous dynamics for scalable reversible generative models. arXiv preprint arXiv:1810.01367, 2018.arxiv.org/abs/1810.01367
- [31]Yameng Gu, Feng Han, Lucas E. Sainburg, Margeaux M. Schade, and Xiao Liu. "simultaneous eeg and fmri signals during sleep from humans", 2026.
- [32]Jonathan Ho, Ajay Jain, and Pieter Abbeel. Denoising diffusion probabilistic models. Advances in neural information processing systems, 33:6840–6851, 2020.arxiv.org/abs/2006.11239
- [33]René J Huster, Stefan Debener, Tom Eichele, and Christoph S Herrmann. Methods for simultaneous eeg-fmri: an introductory review. Journal of Neuroscience, 32(18):6053–6060, 2012.DOI
- [34]Phillip Isola, Jun-Yan Zhu, Tinghui Zhou, and Alexei A Efros. Image-to-image translation with conditional adversarial networks. In Proceedings of the IEEE conference on computer vision and pattern recognition, pages 1125–1134, 2017.arxiv.org/abs/1611.07004
- [35]Wei-Bang Jiang, Li-Ming Zhao, and Bao-Liang Lu. Large brain model for learning generic representations with tremendous eeg data in bci. arXiv preprint arXiv:2405.18765, 2024.arxiv.org/abs/2405.18765
- [36]Jin Jing, Wendong Ge, Shenda Hong, Marta Bento Fernandes, Zhen Lin, Chaoqi Yang, Sungtae An, Aaron F Struck, Aline Herlopian, Ioannis Karakais, et al. Development of expert-level classification of seizures and rhythmic and periodic patterns during eeg interpretation. Neurology, 100(17):e1750–e1762, 2023.DOI
- [37]Tero Karras, Miika Aittala, Timo Aila, and Samuli Laine. Elucidating the design space of diffusion-based generative models. Advances in neural information processing systems, 35:26565–26577, 2022.arxiv.org/abs/2206.00364
- [38]Diederik P Kingma and Jimmy Ba. Adam: A method for stochastic optimization. arXiv preprint arXiv:1412.6980, 2014.arxiv.org/abs/1412.6980
- [39]Diederik P Kingma and Max Welling. Auto-encoding variational bayes. arXiv preprint arXiv:1312.6114, 2013.arxiv.org/abs/1312.6114
- [40]Demetres Kostas, Stephane Aroca-Ouellette, and Frank Rudzicz. Bendr: Using transformers and a contrastive self-supervised learning task to learn from massive amounts of eeg data. Frontiers in Human Neuroscience, 15:653659, 2021.arxiv.org/abs/2101.12037
- [41]Alexander Kovalev, Ilia Mikhеev, and Alexei Ossadtchi. fmri from eeg is only deep learning away: the use of interpretable dl to unravel eeg-fmri relationships. arXiv preprint arXiv:2211.02024, 2022.arxiv.org/abs/2211.02024
- [42]Aaron Kucyi, Lotus Shareef-Trudeau, David Braun, Huiling Peng, Tiara Bounyarith, and Janet Z. Li. "a multi-session simultaneous eeg-fmri dataset with online experience sampling", 2026.DOI
- [44]Vernon J Lawhern, Amelia J Solon, Nicholas R Waytowich, Stephen M Gordon, Chou P Hung, and Brent J Lance. Eegnet: a compact convolutional neural network for eeg-based brain–computer interfaces. Journal of neural engineering, 15(5):056013, 2018.DOI
- [45]Hongli Li, Man Ding, Ronghua Zhang, and Chunbo Xiu. Motor imagery eeg classification algorithm based on cnn-lstm feature fusion network. Biomedical signal processing and control, 72:103342, 2022.DOI
- [46]Yamin Li, Ange Lou, Ziyuan Xu, Shiyu Wang, and Catie Chang. Leveraging sinusoidal representation networks to predict fmri signals from eeg. In Medical Imaging 2024: Image Processing, volume 12926, pages 795–800. SPIE, 2024a.arxiv.org/abs/2311.04234
- [47]Yamin Li, Ange Lou, Ziyuan Xu, Shengchao Zhang, Shiyu Wang, Dario J Englot, Soheil Kolouri, Daniel Moyer, Roza G Bayrak, and Catie Chang. Neurobolt: Resting-state eeg-to-fmri synthesis with multi-dimensional feature mapping. Advances in neural information processing systems, 37:23378–23405, 2024b.arxiv.org/abs/2410.05341
- [48]Yamin Li, Ange Lou, Chang Li, Shiyu Wang, Haatef Pourmottabbed, Ziyuan Xu, Shengchao Zhang, Dario J Englot, Soheil Kolouri, Daniel Moyer, et al. Unebolt: A unified model for eeg-to-bold translation and functional connectivity reconstruction. In Medical Imaging with Deep Learning, 2026.
- [49]Giulia Lioi, Claire Cury, Lorraine Perronnet, Marsel Mano, Elise Bannier, Anatole Lecuyer, and Christian Barillot. "a multi-modal human neuroimaging dataset for data integration: simultaneous eeg and fmri acquisition during a motor imagery neurofeedback task: Xp1", 2021.
- [50]Yaron Lipman, Ricky TQ Chen, Heli Ben-Hamu, Maximilian Nickel, and Matt Le. Flow matching for generative modeling. arXiv preprint arXiv:2210.02747, 2022.arxiv.org/abs/2210.02747
- [51]Xingchao Liu, Chengyue Gong, and Qiang Liu. Flow straight and fast: Learning to generate and transfer data with rectified flow. arXiv preprint arXiv:2209.03003, 2022.arxiv.org/abs/2209.03003
- [52]Nikos K Logothetis. What we can do and what we cannot do with fmri. Nature, 453(7197):869–878, 2008.DOI
- [53]Ilya Loshchilov and Frank Hutter. Decoupled weight decay regularization. arXiv preprint arXiv:1711.05101, 2017.
- [54]Fabien Lotte, Laurent Bougrain, Andrzej Cichocki, Maureen Clerc, Marco Congedo, Alain Rakotomamonjy, and Florian Yger. A review of classification algorithms for eeg-based brain–computer interfaces: a 10 year update. Journal of neural engineering, 15(3):031005, 2018.
- [55]James E Matheson and Robert L Winkler. Scoring rules for continuous probability distributions. Management science, 22(10):1087–1096, 1976.DOI
- [56]Dennis J McFarland and Jonathan R Wolpaw. Brain-computer interfaces for communication and control. Communications of the ACM, 54(5):60–66, 2011.
- [57]Leland McInnes, John Healy, and James Melville. Umap: Uniform manifold approximation and projection for dimension reduction. arXiv preprint arXiv:1802.03426, 2018.arxiv.org/abs/1802.03426
- [58]Mehdi Mirza and Simon Osindero. Conditional generative adversarial nets. arXiv preprint arXiv:1411.1784, 2014.arxiv.org/abs/1411.1784
- [59]Kevin Murphy, Rasmus M Birn, Daniel A Handwerker, Tyler B Jones, and Peter A Bandettini. The impact of global signal regression on resting state correlations: are anti-correlated networks introduced? Neuroimage, 44(3):893–905, 2009.DOI
- [60]Teresa Murta, Marco Leite, David W Carmichael, Patrícia Figueiredo, and Louis Lemieux. Electrophysiological correlates of the bold signal for eeg-informed fmri. Human brain mapping, 36(1):391–414, 2015.DOI
- [61]Rami K Niazy, Christian F Beckmann, Gian Domenico Iannetti, J Michael Brady, and Stephen M Smith. Removal of fmri environment artifacts from eeg data using optimal basis sets. Neuroimage, 28(3):720–737, 2005.pubmed.ncbi.nlm.nih.gov/16150610
- [62]Yuqi Nie, Nam H Nguyen, Phanwadee Sinthong, and Jayant Kalagnanam. A time series is worth 64 words: Long-term forecasting with transformers. arXiv preprint arXiv:2211.14730, 2022.arxiv.org/abs/2211.14730
- [63]Seiji Ogawa, Tso-Ming Lee, Alan R Kay, and David W Tank. Brain magnetic resonance imaging with contrast dependent on blood oxygenation. Proceedings of the National Academy of Sciences, 87(24):9868–9872, 1990.pubmed.ncbi.nlm.nih.gov/2124706
- [64]Yassine El Ouahidi, Jonathan Lys, Philipp Thölke, Nicolas Farrugia, Bastien Pasdeloup, Vincent Gripon, Karim Jerbi, and Giulia Lioi. Reve: A foundation model for eeg-adapting to any setup with large-scale pretraining on 25,000 subjects. arXiv preprint arXiv:2510.21585, 2025.arxiv.org/abs/2510.21585
- [65]Muzaffer Özbey, Onat Dalmaz, Salman UH Dar, Hasan A Bedel, Şaban Öztürk, Alper Güngör, and Tolga Cukur. Unsupervised medical image translation with adversarial diffusion models. IEEE Transactions on Medical Imaging, 42(12):3524–3539, 2023.DOI
- [66]Karl Pearson. Vii. note on regression and inheritance in the case of two parents. Proceedings of the royal society of London, 58(347-352):240–242, 1895.DOI
- [67]Wei Yan Peh, Yuanyuan Yao, and Justin Dauwels. Transformer convolutional neural networks for automated artifact detection in scalp eeg. In 2022 44th Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC), pages 3599–3602. IEEE, 2022.
- [68]Huy Phan, Kaare Mikkelsen, Oliver Y Chén, Philipp Koch, Alfred Mertins, and Maarten De Vos. Sleeptransformer: Automatic sleep staging with interpretability and uncertainty quantification. IEEE Transactions on Biomedical Engineering, 69(8):2456–2467, 2022.DOI
- [69]Yannick Roy, Hubert Banville, Isabela Albuquerque, Alexandre Gramfort, Tiago H Falk, and Jocelyn Faubert. Deep learning-based electroencephalography analysis: a systematic review. Journal of neural engineering, 16(5):051001, 2019.arxiv.org/abs/1901.05498
- [70]Chitwan Saharia, William Chan, Huiwen Chang, Chris Lee, Jonathan Ho, Tim Salimans, David Fleet, and Mohammad Norouzi. Palette: Image-to-image diffusion models. In ACM SIGGRAPH 2022 conference proceedings, pages 1–10, 2022.arxiv.org/abs/2111.05826
- [71]Michael Scheuerer and Thomas M. Hamill. Variogram-based proper scoring rules for probabilistic forecasts of multi-variate quantities. Monthly Weather Review, 143(4):1321–1334, 2015. doi: 10.1175/MWR-D-14-00269.1.DOI
- [72]Robin Tibor Schirrmeister, Jost Tobias Springenberg, Lukas Dominique Josef Fiederer, Martin Glasstetter, Katharina Eggensperger, Michael Tangermann, Frank Hutter, Wolfram Burgard, and Tonio Ball. Deep learning with convolutional neural networks for eeg decoding and visualization. Human brain mapping, 38(11):5391–5420, 2017.
- [73]Paul Scotti, Atmadeep Banerjee, Jimmie Goode, Stepan Shabalin, Alex Nguyen, Aidan Dempster, Nathalie Verlinde, Elad Yundler, David Weisberg, Kenneth Norman, et al. Reconstructing the mind’s eye: fmri-to-image with contrastive learning and diffusion priors. Advances in Neural Information Processing Systems, 36:24705–24728, 2023.
- [74]Stephen M Smith, Christian F Beckmann, Jesper Andersson, Edward J Auerbach, Janine Bijsterbosch, Gwenaëlle Douaud, Eugene Duff, David A Feinberg, Ludovica Griffanti, Michael P Harms, et al. Resting-state fmri in the human connectome project. Neuroimage, 80:144–168, 2013.
- [75]Jascha Sohl-Dickstein, Eric Weiss, Niru Maheswaranathan, and Surya Ganguli. Deep unsupervised learning using nonequilibrium thermodynamics. In International conference on machine learning, pages 2256–2265. pmlr, 2015.
- [76]Kihyuk Sohn, Honglak Lee, and Xinchen Yan. Learning structured output representation using deep conditional generative models. Advances in neural information processing systems, 28, 2015.
- [77]Yang Song and Stefano Ermon. Generative modeling by estimating gradients of the data distribution. Advances in neural information processing systems, 32, 2019.arxiv.org/abs/1907.05600
- [78]Yang Song, Jascha Sohl-Dickstein, Diederik P Kingma, Abhishek Kumar, Stefano Ermon, and Ben Poole. Score-based generative modeling through stochastic differential equations. arXiv preprint arXiv:2011.13456, 2020.arxiv.org/abs/2011.13456
- [79]Yang Song, Prafulla Dhariwal, Mark Chen, and Ilya Sutskever. Consistency models. In Proceedings of the 40th International Conference on Machine Learning, pages 32211–32252, 2023.arxiv.org/abs/2303.01469
- [80]Yonghao Song, Xueyu Jia, Lie Yang, and Longhan Xie. Transformer-based spatial-temporal feature learning for eeg decoding. arXiv preprint arXiv:2106.11170, 2021.arxiv.org/abs/2106.11170
- [81]Jörg Stadler, Torsten Stöter, Nicole Angenstein, Andreas Fügner, Marcel Lommerzheim, Artur Mathysiak, Anke Michalsky, Gabriele Schöps, Johann van der Meer, Susann Wolff, and André Brechmann. "multi-clarid (multimodal category learning and resting-state imaging data)", 2025.
- [82]Akara Supratak, Hao Dong, Chao Wu, and Yike Guo. Deepsleepnet: A model for automatic sleep stage scoring based on raw single-channel eeg. IEEE transactions on neural systems and rehabilitation engineering, 25(11):1998–2008, 2017.
- [83]Yu Takagi and Shinji Nishimoto. High-resolution image reconstruction with latent diffusion models from human brain activity. In Proceedings of the IEEE/CVF conference on computer vision and pattern recognition, pages 14453–14463, 2023.
- [84]Qawi K Telesford, Eduardo Gonzalez-Moreira, Ting Xu, Yiwen Tian, Stanley J Colcombe, Jessica Cloud, Brian E Russ, Arnaud Falchier, Maximilian Nentwich, Jens Madsen, et al. An open-access dataset of naturalistic viewing using simultaneous eeg-fmri. Scientific Data, 10(1):554, 2023.DOI
- [85]Alexander Tong, Kilian Fatras, Nikolay Malkin, Guillaume Huguet, Yanlei Zhang, Jarrid Rector-Brooks, Guy Wolf, and Yoshua Bengio. Improving and generalizing flow-based generative models with minibatch optimal transport. arXiv preprint arXiv:2302.00482, 2023.
- [86]Martijn P Van Den Heuvel and Hilleke E Hulshoff Pol. Exploring the brain network: a review on resting-state fmri functional connectivity. European neuropsychopharmacology, 20(8):519–534, 2010.DOI
- [87]Ashish Vaswani, Noam Shazeer, Niki Parmar, Jakob Uszkoreit, Llion Jones, Aidan N Gomez, Lukasz Kaiser, and Illia Polosukhin. Attention is all you need. Advances in neural information processing systems, 30, 2017.arxiv.org/abs/1706.03762
- [88]Diego Vidaurre, Romesh Abeysuriya, Robert Becker, Andrew J Quinn, Fidel Alfaro-Almagro, Stephen M Smith, and Mark W Woolrich. Discovering dynamic brain networks from big data in rest and task. NeuroImage, 180:646–656, 2018.DOI
- [89]Guangyu Wang, Wenchao Liu, Yuhong He, Cong Xu, Lin Ma, and Haifeng Li. Eegpt: Pretrained transformer for universal and reliable representation of eeg signals. Advances in Neural Information Processing Systems, 37:39249–39280, 2024.DOI
- [90]Qinfan Xiao, Ziyun Cui, Chi Zhang, Siqi Chen, Wen Wu, Andrew Thwaites, Alexandra Woolgar, Bowen Zhou, and Chao Zhang. Brainomni: A brain foundation model for unified eeg and meg signals. arXiv preprint arXiv:2505.18185, 2025.arxiv.org/abs/2505.18185
- [91]Chaoqi Yang, M Westover, and Jimeng Sun. Biot: Biosignal transformer for cross-data learning in the wild. Advances in Neural Information Processing Systems, 36:78240–78260, 2023a.DOI
- [92]Chaoqi Yang, Cao Xiao, M Brandon Westover, and Jimeng Sun. Self-supervised electroencephalogram representation learning for automatic sleep staging: model development and evaluation study. JMIR AI, 2(1):e46769, 2023b.DOI
- [93]Ling Yang, Zixiang Zhang, Zhilong Zhang, Xingchao Liu, Minkai Xu, Wentao Zhang, Chenlin Meng, Stefano Ermon, and Bin Cui. Consistency flow matching: Defining straight flows with velocity consistency. arXiv preprint arXiv:2407.02398, 2024.arxiv.org/abs/2407.02398
- [94]BT Thomas Yeo, Fenna M Krienen, Jorge Sepulcre, Mert R Sabuncu, Danial Lashkari, Marisa Hollinshead, Joshua L Roffman, Jordan W Smoller, Lilla Zöllei, Jonathan R Polimeni, et al. The organization of the human cerebral cortex estimated by intrinsic functional connectivity. Journal of neurophysiology, 2011.DOI















