betaFeedback

WorksPhysics and Astronomy

Achieving a Near-Ideal Silicon Crystal Neutron Interferometer using Sub-Micron Fabrication Techniques

Abstract

Perfect-crystal neutron interferometry which is analogous to Mach-Zehnder interferometry, uses Bragg diffraction to form interfering neutron paths. The measured phase shifts can be used to probe many types of interactions whether it be nuclear, electromagnetic, gravitational, or topological in nature. For a perfect-crystal interferometer to preserve coherence, the crystal must possess a high degree of dimensional tolerance as well as being relatively defect-free with minimal internal stresses. In the past, perfect-crystal neutron interferometers have been produced by a two step process. First, a resin diamond wheel would be used to remove excess material and shape the interferometer. Afterword, the crystal would be etched in order to remove surface defects and elevate strains. This process has had limitations in terms of repeatability and in maximizing the final contrast, or fringe visibility, of the interferometer. We have tested various fabrication and post-fabrication techniques on a single perfect-crystal neutron interferometer and measured the interferometer's performance at each step. Here we report a robust, repeatable non-etching fabrication process with high final contrast. For the interferometer used in this work, we achieved contrasts of greater than 90% several separate times and ultimately finished with an interferometer that has 92% contrast and a uniform phase distribution.

Introduction

Neutron interferometry utilizes the wave-like properties of neutron beams to study aspects of fundamental and applied physics. It has been used to demonstrate 4π4\pi spinor rotation [1], orbital angular momentum [2, 3], berry phases [4], Cheshire cats and weak measurements [5], GHZ states [6], probe nuclear structure [7], and search for beyond the Standard Model physics [8, 9, 10]. The neutron’s unique sensitivity is due to its charge neutrality, magnetic dipole moment and non-zero spin, and its inherent quantum nature. Measuring the neutron’s phase allows precision and sensitivity not found in other neutron scattering techniques.

Perfect-crystal neutron interferometers were first produced in the mid-1970s [11, 12] following the introduction of x-ray interferometers [13] a decade before. Until recently the techniques for fabricating interferometer crystals has had little innovation [14, 15]. In order to minimize impurities, interferometers are constructed from float-zone (FZ) grown [16, 17] silicon ingots. The ingots are machined such that there are multiple crystal blades extruding from a common base. The large common base is necessary for stability and, most importantly, to align each crystal blade relative to each other at the sub-arc second level. Only very recently has a neutron interferometer been shown to operate with blades on separate bases [18]. A collection of neutron interferometers are shown in Figure 1.

Interferometer crystals

Figure 1. Interferometer crystals. Hera, the largest LLL crystal, is approximately 10 cm × 10 cm in size. Talos, the subject of this work, is the smallest.

Traditionally, the ingots are machined into the correct shape using a resin diamond wheel (200 grit to 600 grit) [19] with an accuracy of 10’s of microns. The machining damages the crystal blade surface and creates microcracking that can penetrate deep into the subsurface [20, 21, 22]. Microcracking, subsurface stresses, and other defects are removed by etching the crystal surfaces. The etching process is done iteratively and removes only several microns of surface material at a time. This is because excessive etching can decrease blade parallelism and has been shown to negatively impact the crystal’s performance.

For example, the crystal known as Hades (see Figure 1) was made in 1988 [23] at the University of Missouri-Columbia. It was etched in a bath of hydrofluoric, acetic, and nitric acids at concentrations of 18 %, 25 %, and 57 % respectively. This process was repeated five times and a total of 40 μm40\,\mu\mathrm{m} of material was removed from each blade (20 μm20\,\mu\mathrm{m} per side). After each etch the contrast of Hades was measured. The final maximum of contrast of Hades at that time being 70 %.

The etching of an interferometer has poor repeatability. The exothermic reactions taking place cause currents in the acid bath and results in uneven flow in the channels between the crystal blades. A greater issue is the formation of bubbles that adhere to the silicon surfaces. These issues cause variable etch rates along the interferometer blades that negatively effect the parallelism and geometry of the resulting neutron interferometer. The varying etch rate can be mediated, in part, by constantly moving the interferometer inside the bath. Also, the acid bath can be ‘kick-started’ by the introduction of several grams of silicon powder minutes before submerging the interferometer. This starts the exothermic reaction and raises the bath temperature such that the etch rate is more constant in time. In practice, neither moving the crystal nor ‘kick-starting’ the reaction can totally remove the factors that led to poor etching consistency.

Schematic of a neutron interferometer with phase flag, diffracting blades, analyzer crystal, cadmium sheets, and detectors

Figure 2. Neutrons entering the interferometer are split via the first diffracting blade (S) into 2 paths. The paths are again diffracted by a mirror blade (M). Lastly, the 2 paths interfere in an analyzer crystal (A). Any differences between the paths modulates the intensities IOI_O and IHI_H measured at the detectors. By rotating a phase flag by an angle of δ\delta one can vary IOI_O and IHI_H. Normally, the distance LL is significantly long enough such that the I1I_1 and I4I_4 beams escape the interferometer without striking the analyzer crystal. This is not the case for the interferometer Talos. Here neutron absorbing cadmium (Cd) sheets placed behind the analyzer crystal to eliminate I1I_1 and I4I_4 from reaching the detectors.

Neutron interferometers make use of several different sizes and configurations. The construction of new interferometers is needed for next generation neutron interferometry experiments. Due to the expense of FZ material, the iterative machining process, and inconstancy of etching, a more dependable fabrication process is needed. Here we discuss sub-micron fabrication technique that can minimize and even eliminate the need for etching and yet still produce a high-contrast, high-quality interferometer. These techniques were tested on an existing neutron interferometer.

Neutron Interferometry

In perfect-crystal neutron interferometry a neutron wave is manipulated using Bragg diffraction inside a crystal lattice. Figure 2 shows a schematic of a Laue-Laue-Laue (LLL) type interferometer. A mono-energetic neutron beam enters the interferometer and diffracts from the first blade (Splitter : S) resulting in the incident neutron beam splitting into two distinct paths: a forward diffracted (path I) and a reflected one (path II). Internal crystal blade(s) (Mirror : M) reflect the neutron paths so that they interfere with each other in a final blade (Analyzer : A). This setup is analogous to a Mach-Zehnder interferometer in light optics. In reality, there is only one neutron entering the interferometer at time and it is the neutron’s wave function that is shared between the two paths. Or in other words, a neutron interferometer is a perfect example of self-interference. The exiting neutron beams labeled IOI_O and IHI_H for the O-beam and H-beam, respectively, are detected with near 100 % efficiency using 3He{}^{3}\mathrm{He} tubes. Differences in the phase that the neutron accumulates between paths I and II modulate the intensity at the detectors. Phase shifts can be due to physical materials placed in the beam paths as well as forces and the particulars of the neutron’s trajectory. A device called a phase flag made from optically flat 1.5 mm thick quartz is placed inside the interferometer. Rotating the phase flag varies its effective thickness along each path resulting in a modulation of the outgoing IOI_O and IHI_H intensities.

A selection of interferometer crystals of various sizes and geometries are shown in Fig. 1. Of the interferometers shown in Fig. 1 only Hera had a maximum contrast above 80 % prior to this work. As one can see in Fig. 1, a variety of crystal shapes and sizes are needed to meet the requirements of a diverse set of experiments. Recently, ultra precision machining has been utilized to cut a close to ideal 2-blade interferometer crystal [24]. In addition, post-fabrication annealing has shown to alleviate internal crystal stresses and improve interferometer contrast [25].

Contrast

The intensity measured by the neutron detectors is a function of the phase difference between the two paths, Δϕ=ϕII−ϕI\Delta\phi= \phi_{II} - \phi_I, and is given by

IO∝∣ΨIeiϕI+ΨIIeiϕII∣2∝[1+cos⁡(Δϕ)].(1)I_O \propto\left|\Psi_I e^{i\phi_I}+\Psi_{II}e^{i\phi_{II}}\right|^2 \propto[1+\cos(\Delta\phi)]. \tag*{(1)}

In practice, IOI_O and IHI_H are fit to the functions

IO=c0+c1cos⁡[Δϕ+Δϕ0+Δϕpf(δ)](2)I_O = c_0+c_1\cos[\Delta\phi+\Delta\phi_0+\Delta\phi_{\mathrm{pf}}(\delta)] \tag*{(2)}
IH=c2−c1cos⁡[Δϕ+Δϕ0+Δϕpf(δ)].(3)I_H = c_2-c_1\cos[\Delta\phi+\Delta\phi_0+\Delta\phi_{\mathrm{pf}}(\delta)]. \tag*{(3)}

where c0c_0, c1c_1, c2c_2, and Δϕ0\Delta\phi_0 are fit parameters. Note that IH+IO=c0+c2=I_H+I_O=c_0+c_2= constant; meaning that no neutrons are created or destroyed in the interferometer. The phase Δϕ0\Delta\phi_0 is the phase shift of an empty interferometer and can vary over time due to external factors like ambient temperature fluctuations [26]. The phase due to the phase flag Δϕpf(δ)\Delta\phi_{\mathrm{pf}}(\delta) is varied by rotating the flag by an angle of δ\delta. The phase Δϕ\Delta\phi is the parameter of experimental interest and can be due to a physical sample inside the interferometer or a field depending on the configuration of the apparatus. The intensity as a function of δ\delta is called an interferogram. An interferogram showing the initial and final results of this work is shown in Fig. 3.

The contrast, or fringe visibility, is defined for the IO,HI_{O,H} beams as

C=amplitudemean=c1c0,2.(4)\mathcal{C}=\frac{\text{amplitude}}{\text{mean}}=\frac{c_1}{c_{0,2}}. \tag*{(4)}

The contrast is a useful quantity for determining the quality of an interferometer. Ideally, C=100%\mathcal{C}=100\% in the O-beam. However, crystal imperfections, internal stresses, surface roughness, and geometric inaccuracies cause the contrast of practical interferometers to be less than 100 % [27, 28]. The reflection and transmission coefficients for diffracting into the H-beam limits the maximum H-beam contrast to ≈40\approx40 % [29].

Test Interferometer: Talos

The interferometer called Talos was created over 20 years ago using scrap FZ material. It is a LLL type interferometer with a (111) Bragg vector parallel to the blade surface. Physically, Talos is closer in size to a perfect-crystal x-ray interferometer [30] than that of a working neutron interferometer. However, it is of the same geometry and Bragg vector as our most utilized neutron interferometer. Talos has a blade-to-blade separation of L=10L = 10 mm with a blade height of 15 mm. The blades began this work D≈1D \approx1 mm thick. Talos successfully demonstrated contrast after what was described as a “quick-and-dirty” fabrication process. Its initial contrast was around 30 % but it has fallen lower throughout the years (a phenomenon sometimes observed with other crystals as well).

Due to its relatively small size and thus the limited sample size that it can accommodate, Talos has rarely been used at the facility. One exception, where its size was an advantage, was in an attempted effort to buoyantly float an interferometer crystal [31]. Neutrons were an early test-bed of the gravitationally induced quantum interference and the equivalence principle [32, 33, 34, 35] in a series of so-called “COW” experiments, a name derived from the original author’s last names [12]. Each measurement of gravity using neutrons was systematically limited and disagreed with the theoretically expected result by several percent. However, each new neutron measurement improved on systematics. The last COW measurement determined Δϕg,expt=(210.28±0.23) rad/A˚\Delta\phi_{g,\mathrm{expt}} = (210.28 \pm0.23)\,\mathrm{rad}/\mathring{\mathrm{A}} by rotating an interferometer crystal to an angle of π/4\pi/4 rad. This result still disagreed with the predicted value of Δϕg,theo=(212.119±0.021) rad/A˚\Delta\phi_{g,\mathrm{theo}} = (212.119 \pm0.021)\,\mathrm{rad}/\mathring{\mathrm{A}} by 0.8 %, but it had cut the discrepancy by a factor of 2.5 from the previous COW result. Suspending the crystal in a buoyant liquid was attempted in order to completely eliminate systematics caused by the induced stresses as the crystal is rotated. The size of Talos allowed testing of this suspension using a small volume of liquid. Ultimately this approach was not pursued and currently the equivalence principle has been established at the 10−1210^{-12} level through atom interferometry [36].

For the last several years, Talos has been used to test various fabrication techniques. The advantages of Talos are that it had established non-zero contrast, its small area allows for faster turnaround, and since it has struggled to find uses elsewhere, permanent destruction of it would not be a major disruption to activities at the facility. Over 12 fabrication stages Talos’ surfaces were either re-fabricated, the crystal etched, or the crystal was annealed. The resulting fabrication process is shown in Figure 4. At each fabrication stage the performance of Talos was measured using neutrons.

Figure 4. The fabrication processes. The common pathway to fabricate an interferometer crystal is highlighted in grey. Here a float zone silicon ingot is machined and then etched. The etching process is repeated until the measured contrast of the interferometer no longer improves with each etch. In our process (blue) after a rough cut of the ingot, more precise and less damaging machining is done. Optional steps are depicted by the dotted arrows. Note that no more than one etch is required.

Experiment

Facilities

The neutron measurements and annealing were carried out at the NIST Center for Neutron Research (NCNR) in Gaithersburg, MD. The NCNR provides neutrons for scientific research using a heavy water moderated 20 MW reactor. There are two operating Neutron Interferometry and Optics Facilities (NIOF) at the NCNR [37, 38]. The contrast of Talos was measured inside the Hutch (see Figure 5) where vibration and thermal isolation allow for achieving maximum contrast under the best possible experimental conditions. The neutron wavelength used here was λ=2.71\lambda= 2.71 Å with a corresponding Bragg angle of 0.447 rad (25.6°). The incident beam was 2 mm in height and either 2 mm or 1 mm wide. Generally, a smaller incident beam will have a larger contrast. The interferometer was supported by a rotation stage, a yy-translation stage, and zz-stage. Because Talos’ blade-to-blade distance LL is so small, the forward diffracted beams from the mirror crystal (I1I_1 and I4I_4) can be reflected in the analyzer crystal and reach the detectors. To prevent this, neutron absorbing cadmium was placed behind the analyzer crystal.

The Hutch at the NIOF, including the interferometer and labeled components

Figure 5. The Hutch at the NIOF provides an isolated environment for stable neutron interferometry measurements. Components: 1 Collimator/shutter; 2 Evacuated beam transport tube; 3 Focusing pyrolytic graphite monochromator; 4 Translation stage; 5 Outer environmental enclosure; 6 Primary vibration isolation stage; 7 Acoustic and thermal isolation enclosure; 8 Secondary vibration isolation stage; 9 Enclosure for interferometer and detectors. Interferometer.

The set of high precision fabrication and several etching steps were performed by Neutron Optics INC. [39]. An ultra precision machining center [40], typically used for single point diamond turning optical elements, was modified and adapted for a variety of fabrication methods.

The first step was to bring the initial geometric tolerance (Stage 0, Table I) of Talos (Figure 6(a)) over an order of magnitude closer to an ideal geometry (equal blade thickness DD and separation LL), each subsequent method strived to have a tolerance similar to the one from the stage seen in Figure 6(b). Precision measurements of the interferometer geometry were performed via a coordinate measuring machine (CMM)-style contact measurement using an amplified strain gauge in situ and without having to remove the crystal or alter the setup for cutting. The tip is a modified 1 mm ruby sphere with a dedicated smoothed flat area free from abrupt edges preventing Hertzian contact. In order to minimize risk of damage, the contact force of 2 g never exceeds the yield point of silicon. The measurements were checked for temperature stability and could be compensated in case of linear drift when a time-consuming, dense grid of measurements is desired. A precision silicon nitride reference ball is used for absolute measurements and calibration. The gauge is repeatable to 0.05 μ\mum. Typical surface measurements on Talos were determined to be accurate to ± 0.2 μ\mum at 21 °C, consist of about 50 total points and took approximately 10 minutes per surface. The fabrication stages, categorized into resurfacing (R), etching (E) and annealing (A), are summarized in Table I. Figure 7 shows the variation in surface height deceased by a order of magnitude following the ultra precision machining.

Front and back blade dimensional measurements of Talos at fabrication stages 0 and 10

Figure 6. Front and back blade dimensional measurements of Talos taken at (a) fabrication stage 0 and (b) fabrication stage 10 (see Table I). Values are relative to an ideal geometry with L=10.855L = 10.855 mm and D=0.870D = 0.870 mm. Measurements were made at 21 °C. Contour lines are spaced by 1 μm.

Measurements showing local variation of the surface height of Talos

Figure 7. (a-b) Measurements showing local variation of the surface height of Talos. The left column was taken at fabrication stage 0 and the right column at stage 10 (see Table I). (c-f) Line profiles from (a) and (b) showing the variation. Measurements were made at 21 °C.

The method in stage 1 consisted of a lapping method using a self-charging brass lap submerged in a 0.5 μ\mum particle size diamond slurry. Fabrication stage 3 utilized a polishing technique resembling a chemo-mechanical polishing process [41]. Stage 6 employed a water-cooled ‘pinch ruling’ process [42], where each blade is cut by two opposing single point diamond cutters in the ductile regime [43]. Stages 9 and 10 were experimental methods based on elastic emissions machining [44] showing considerable contrast without the need for etching or annealing.

Post fabrication annealing took place in a large commercial tube furnace. The interferometer was placed on a graphite crucible centering the crystal in the oven bore. The oven’s temperature was raised at a rate of 1 °C/min to 200 °C and held at that temperature for 2 h. It was then raised to a final annealing temperature of 800 °C at a slower rate of 0.5 °C/min. The crystal was held at the final temperature for 12 h and then lowered back to room temperature at a rate of -0.5 °C/min. Annealing has improved the contrast of several interferometers [25], most notably Hera. However, other interferometers, namely Dionysus and Achilles, have had no noticeable change in contrast post annealing. For the first time, annealing has been shown to have negative effects on the interferometer overall performance in stages 4 and 9.

Contrast & Phase Maps

To measure interferometer contrast the crystal is translated vertically and horizontally allowing the incident beam to illuminate different points along the crystal face. At each point the phase flag is rotated ± 2.5° creating an interferogram like those in Figure 3 from which the contrast can be determined via Eq. (2). Contrast maps of four stages are shown in Figure 8. An interferometer can exhibit a strongly preferred yy-zz position called a sweet spot. An example of this can be seen in Figure 8(c).

Figure 3. Interferograms of the maximum contrast, or fringe visibility, observed in the IOI_O beam for the initial and final stage (see Table I) of fabrication. The ⋄\diamond (∙\bullet) symbols represent the IOI_O intensity for the initial (final) stage. Lines are fits to the data using Eqn. (2) and the uncertainties shown are purely statistical. See the text for a description the techniques used at each fabrication stage.

Contrast maps of Talos

Figure 8. Contrast maps of Talos. The color scale is the same throughout. (a) Stage 0; an early contrast map of the interferometer. (b) Stage 2; having no measurable contrast followed by a 5 minute acid etch. (c) Stage 4; after the results in (b) the faces of the interferometer were re-fabricated and the crystal was annealed. Contrast decreased and a sweet spot appeared. (d) Stage 12; high contrast as restored after re-fabricating the crystal surfaces. No data was taken at coordinate Z = 18 mm.

Table I shows the results of various processes on the interferometer and its effect on the contrast. The maximum contrast observed was over 90 % compared to a minimum of 8 % following annealing. For fabrication stage 2 the crystal was etched in a solution of nitric acid to hydrofluoric acid (HNO3_3:HF) at a 60:1 volume ratio for 5 min removing approximately 1 μ\mum of silicon material off each blade. We were able to destroy and then completely restore contrast of the interferometer several times indicating that the fabrication stages caused no permanent stress or damage to the crystal.

The measured phase Δϕ0\Delta\phi_0 at each point is plotted in Figure 9. Points of low contrast where the fitted uncertainty σΔϕ0≥20∘\sigma_{\Delta\phi_0} \ge20^\circ are omitted (white pixels) in the phase maps. Since the interferometer measures Δϕ\Delta\phi modulo 2π2\pi, a 2π2\pi phase step can be seen in the middle of Figure 9(c). A clear, smooth gradient can be seen in the phase maps corresponding to high contrast.

Phase maps of Talos for the same cases shown in Fig. 8

Figure 9. Phase maps of Talos for the same cases shown in Figure 8. The color scale is the same throughout. White pixels in (a) and (c) correspond to areas of low contrast where Δϕ\Delta\phi uncertainties are greater or equal than 20∘20^\circ and have been omitted. No data was taken at coordinate Z=18Z = 18 mm for (d). In (c) a modulus of 2π2\pi is crossed in the middle.

The contrast variation is defined as the mean contrast ± 1 standard deviation. As shown in Figure 8(d), Talos doesn’t currently exhibit a sweet spot and instead has a roughly uniform contrast map. The largest improvements in contrast (stages 2, 5, and 7) followed etching using HNO3_3:HF mixture or KOH. KOH is usually avoided because it etches anisotropically, but was tried here to avoid using more dangerous HF solutions.

Fab. StageProcess (See Key)Contrast, CC Var. (%)Contrast, CC Max. (%)
0initial7±47 \pm420±320 \pm3
1R & Anilnil
2E82±1382 \pm1397±497 \pm4
3R61±2161 \pm2187±787 \pm7
4A33±2033 \pm2076±676 \pm6
5E5±275 \pm2790±690 \pm6
6R4±54 \pm524±124 \pm1
7E22±1522 \pm1545±245 \pm2
8R9±109 \pm1040±340 \pm3
9A3±23 \pm28±28 \pm2
10R34±1634 \pm1675±375 \pm3
11R7±57 \pm523±323 \pm3
12R71±1871 \pm1892±492 \pm4

Table 1. Maximum Contrast and the contrast variation of Talos after various processes. Note Stage 4 and 5 were taken using a narrower slit (2 mm×1 mm2\ \mathrm{mm} \times1\ \mathrm{mm}) which likely increased the contrast measured during those runs. Key: Resurfaced (R), Annealed (A), Etched (E)

Discussion

In this work we have shown that advanced fabrication using a diamond turning machine produces a high-quality, high-contrast neutron interferometer. One can achieve this high contrast without the need for performing several lengthy acid etchs. Additionally, for the first time we have shown a negative response to annealing for a neutron interferometer which was improved after an etch. A similar behavior was observed in an x-ray interferometer [45].

Neutron interferometry requires highly precise silicon fabrication techniques that can be consistently applied to a relatively large surface area (12 cm212\ \mathrm{cm}^{2}). Specifically, the imaging of samples inside an interferometer generally requires using relatively large (1010 mm × 1010 mm) incident beams [46] [3]. Therefore, sample imaging requires uniform contrast and phase profiles over large crystal surfaces. Our techniques have shown uniformity to a high degree over such areas. Higher performance crystals are needed for the next generation of neutron interferometry experiments including a split neutron interferometer [18], a decoherence-free subspace neutron interferometer[47], and for future facilities [48].

In the past, interferometer crystals were cut and then etched in an iterable process until a maximum contrast was observed. Here we have eliminated etching and iterated, as a test, the fabrication. This type of fabrication is much slower, but a much more reproducible and controlled action. The reduction or complete elimination of the iterable etching process also removes safety and disposal concerns related to using a large volume of strong acids. Disposal concerns are especially consequential for fabricating an interferometer made of germanium; a material that becomes radioactive during every iterable contrast map. In the near future, a large interferometer crystal, similar in geometry to Hera (see Figure 1), using these new techniques will be deployed at the NIST interferometer facilities.

Acknowledgements

This work was supported by the Canadian Excellence Research Chairs (CERC) program, the Natural Sciences and Engineering Council of Canada (NSERC) Discovery program, the Canada First Research Excellence Fund (CFREF), Triangle Universities Nuclear Laboratory (TUNL), the National Institute of Standards and Technology (NIST) and the US Department of Energy, Office of Nuclear Physics, under Interagency Agreement 8924301SSC0000025.

References

References

  1. [5]A. Danner, H. Lemmel, R. Wagner, S. Sponar, Y. Hasegawa, Neutron interferometer experiments studying fundamental features of quantum mechanics, Atoms 11 (6) (2023). doi:10.3390/atoms11060098.DOI
  2. [6]D. Erdősi, M. Huber, B. C. Hiesmayr, Y. Hasegawa, Proving the generation of genuine multipartite entanglement in a single-neutron interferometer experiment, New Journal of Physics 15 (2) (2013) 023033. doi:10.1088/1367-2630/15/2/023033.DOI
  3. [7]R. Haun, F. E. Wietfeldt, M. Arif, M. G. Huber, T. C. Black, B. Heacock, D. A. Pushin, C. B. Shahi, Precision measurement of the neutron scattering length of ⁴He using neutron interferometry, Physical Review Letters 124 (2020) 012501. doi: 10.1103/PhysRevLett.124.012501.DOI
  4. [8]B. Heacock, T. Fujii, R. W. Haun, A. Henins, K. Hirota, T. Hosobata, M. G. Huber, M. Kitaguchi, D. A. Pushin, H. Shimizu, M. Takeda, R. Valdilliez, Y. Yamagata, A. R. Young, Pendellösung interferometry probes the neutron charge radius, lattice dynamics, and fifth forces, Science 373 (6560) (2021) 1239–1243. doi:10.1126/science.abc2794.DOI
  5. [9]H. Lemmel, P. Brax, A. Ivanov, T. Jenke, G. Pignol, M. Pitschmann, T. Potocar, M. Wellenzohn, M. Zawisky, H. Abele, Neutron interferometry constrains dark energy chameleon fields, Physics Letters B 743 (0) (2015) 310 – 314. doi:10.1016/j.physletb.2015.02.063.DOI
  6. [10]K. Li, M. Arif, D. G. Cory, R. Haun, B. Heacock, M. G. Huber, J. Nsofini, D. A. Pushin, P. Saggu, D. Sarenac, C. B. Shahi, V. Skavysh, W. M. Snow, A. R. Young, Neutron limit on the strongly-coupled chameleon field, Physical Review D: Particles and Fields 93 (2016) 062001. doi:10.1103/PhysRevD.93.062001.DOI
  7. [11]H. Rauch, W. Treimer, U. Bonse, Test of a single crystal neutron interferometer, Physics Letters A 47 (1974) 369–371. doi:10.1016/0375-9601(74)90132-7.DOI
  8. [12]R. Colella, A. W. Overhauser, S. A. Werner, Observation of gravitationally induced quantum interference, Physical Review Letters 34 (23) (1975) 1472–1474. doi:10.1103/PhysRevLett.34.1472.DOI
  9. [13]U. Bonse, M. Hart, An X-ray interferometer, Applied Physics Letters 6 (8) (1965) 155–156. doi:10.1063/1.1754212.DOI
  10. [14]W. Treimer, Experience with the production of single-crystal interferometers, in: U. Bonse, H. Rauch (Eds.), Neutron Interferometry, Clarendon Press. Oxford, 1979, pp. 87–96.
  11. [15]M. Zawisky, J. Springer, R. Farthofer, U. Kuetgens, A large-area perfect crystal neutron interferometer optimized for coherent beam-deflection experiments: Preparation and performance, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 612 (2) (2009) 338–344. doi:10.1016/j.nima.2009.09.128.DOI
  12. [16]W. Zulehner, Historical overview of silicon crystal pulling development, Materials Science and Engineering: B 73 (1) (2000) 7–15. doi:10.1016/S0921-5107(99)00427-4.
  13. [17]A. Muiznieks, J. Virbulis, A. Lüdge, H. Riemann, N. Werner, Floating zone growth of silicon, in: P. Rudolph (Ed.), Handbook of Crystal Growth (Second Edition), second edition Edition, Handbook of Crystal Growth, Elsevier, Boston, 2015, pp. 241–279. doi:10.1016/B978-0-444-63303-3.00007-9.DOI
  14. [18]H. Lemmel, M. Jentschel, H. Abele, F. Lafont, B. Guerard, C. P. Sasso, G. Mana, E. Massa, Neutron interference from a split-crystal interferometer, Journal of Applied Crystallography 55 (4) (08 2022). doi:10.1107/S1600576722006082.DOI
  15. [19]B. Allman, D. Jacobson, W.-T. Lee, K. Littrell, S. Werner, Neutron interferometry instrumentation at murr, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 412 (2) (1998) 392–419. doi:10.1016/S0168-9002(98)00479–3.DOI
  16. [20]Z. Zhong, Ductile or partial ductile mode machining of brittle materials, The International Journal of Advanced Manufacturing Technology 21 (8) (2003) 579–585. doi:10.1007/s00170-002-1364-5.DOI
  17. [21]S. T. Smith, Machining of silicon using high-speed miniature diamond cutters, Journal of Physics D: Applied Physics 23 (5) (1990) 607. doi:10.1088/0022-3727/23/5/022.DOI
  18. [22]J. Yan, T. Asami, H. Harada, T. K. Arakawa, Fundamental investigation of subsurface damage in single crystalline silicon caused by diamond machining, Precision Engineering 33 (4) (2009) 378–386. doi:10.1016/j.precisioneng.2008.10.008.DOI
  19. [23]R. Clothier, Coherence experiments with neutron matter waves, Ph.D. thesis, University of Missouri-Columbia (05 1991).
  20. [24]B. Heacock, R. Haun, K. Hirota, T. Hosobata, M. G. Huber, M. E. Jamer, M. Kitaguchi, D. A. Pushin, H. Shimizu, I. Taminiau, Y. Yamagata, T. Yamamotod, A. R. Young, Measurement and alleviation of subsurface damage in a thick-crystal neutron interferometer, Acta Crystallographica Section A 75 (6) (2019). doi:10.1107/S2053273319011604.DOI
  21. [25]B. Heacock, M. Arif, D. G. Cory, T. Gnaupel-Herold, R. Haun, M. G. Huber, M. E. Jamer, J. Nsofini, D. A. Pushin, D. Sarenac, I. Taminiau, A. R. Young, Increased interference fringe visibility from the post-fabrication heat treatment of a perfect crystal silicon neutron interferometer, Review of Scientific Instruments 89 (2) (2018) 023502. doi:10.1063/1.5008273.DOI
  22. [26]P. Saggu, T. Mineeva, M. Arif, D. G. Cory, R. Haun, B. Heacock, M. G. Huber, K. Li, J. Nsofini, D. Sarenac, C. B. Shahi, V. Skavysh, W. M. Snow, S. A. Werner, A. R. Young, D. A. Pushin, Decoupling of a neutron interferometer from temperature gradients, Review of Scientific Instruments 87 (12) (2016) 123507. doi:10.1063/1.4971851.DOI
  23. [27]J. Nsofini, K. Ghofrani, D. Sarenac, D. G. Cory, D. A. Pushin, Quantum-information approach to dynamical diffraction theory, Physical Review A 94 (2016) 062311. doi:10.1103/PhysRevA.94.062311.DOI
  24. [28]J. Nsofin, D. Sarenac, K. Ghofrani, M. G. Huber, M. Arif, D. G. Cory, D. A. Pushin, Noise refocusing in a five-blade neutron interferometer, Journal of Applied Physics 122 (5) (2017) 054501. doi:10.1063/1.4996866.
  25. [29]H. Rauch, S. A. Werner, Neutron Interferometry: Lessons in Experimental Quantum Mechanics, Wave-Particle Duality, and Entanglement, 2nd Edition, Oxford University Press, 2015.
  26. [30]R. D. Deslattes, A. Henins, H. A. Bowman, R. M. Schoonover, C. L. Carroll, I. L. Barnes, L. A. Machlan, L. J. Moore, W. R. Shields, Determination of the avogadro constant, Physical Review Letters 33 (1974) 463–466. doi:10.1103/PhysRevLett.33.463.DOI
  27. [31]G. Kaiser, N. Armstrong, F. Wietfeldt, M. Huber, T. Black, M. Arif, D. Jacobson, S. Werner, Gravitationally induced quantum interference using a floating interferometer crystal, Physica B386 (2) (2006) 1384 – 1387, proceedings of the Eighth International Conference on Neutron Scattering. doi:10.1016/j.physb.2006.05.206.
  28. [32]J. L. Staudenmann, S. A. Werner, R. Colella, A. W. Overhauser, Gravity and inertia in quantum mechanics, Physical Review A21 (5) (1980) 1419–1438. doi:10.1103/PhysRevA.21.1419.
  29. [33]S. A. Werner, H. Kaiser, M. Arif, R. Clothier, Neutron interference induced by gravity: New results and interpretations, Physica B151 (1-2) (1988) 22 – 35. doi:10.1016/0378-4363(88)90141-6.DOI
  30. [34]M. Arif, M. S. Dewey, G. L. Greene, D. Jacobson, S. Werner, X-ray determination of the elastic deformation of a perfect crystal neutron interferometer: implications for gravitational phase shift experiments, Physics Letters A184 (2) (1994) 154 – 158. doi:10.1016/0375-9601(94)90768-4.
  31. [35]K. C. Littrell, B. E. Allman, S. A. Werner, Two-wavelength-difference measurement of gravitationally induced quantum interference phases, Physical Review A56 (3) (1997) 1767–1780. doi:10.1103/PhysRevA.56.1767.
  32. [36]P. Asenbaum, C. Overstreet, M. Kim, J. Curti, M. A. Kasevich, Atom-interferometric test of the equivalence principle at the 10−12 level, Phys. Rev. Lett. 125 (2020) 191101. doi:10.1103/PhysRevLett.125.191101.
  33. [37]C. Shahi, M. Arif, D. Cory, T. Mineeva, J. Nsofin, D. Sarenac, C. Williams, M. Huber, D. Pushin, A new polarized neutron interferometry facility at the NCNR, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 813 (2016) 111 – 122. doi:10.1016/j.nima.2016.01.023.
  34. [38]D. A. Pushin, M. G. Huber, M. Arif, C. B. Shahi, J. Nsofin, C. J. Wood, D. Sarenac, D. G. Cory, Neutron interferometry at the National Institute of Standards and Technology, Advances in High Energy Physics (2014) 687480doi:10.1155/2015/687480.
  35. [39]Certain trade names and company products are mentioned in the text or identified in an illustration in order to adequately specify the experimental procedure and equipment used. In no case does such identification imply recommendation or endorsement by the National Institute of Standards and Technology, nor does it imply that the products are necessarily the best available for the purpose.
  36. [40]Model 350FG. Moore Nanotechnology Systems, LLC.
  37. [41]Y. Namba, N. Ohnishi, S. Yoshida, K. Harada, K. Yoshida, T. Matsuo, Ultra-precision float polishing of calcium fluoride single crystals for deep ultra violet applications, CIRP Annals 53 (1) (2004) 459–462. doi:10.1016/S0007-8506(07)60739–2.
  38. [42]US Patent #10,512,974.
  39. [43]P. N. Blake, R. O. Scattergood, Ductile-regime machining of germanium and silicon, Journal of the American Ceramic Society 73 (4) (1990) 949–957. doi:10.1111/j.1151–2916.1990.tb05142.x.
  40. [44]Y. Mori, K. Yamauchi, K. Endo, Elastic emission machining, Precision Engineering 9 (3) (1987) 123–128. doi:10.1016/0141–659(87)90029–8.
  41. [45]E. Massa, C. P. Sasso, M. Fretto, L. Martino, G. Mana, X-ray phase-contrast topography to measure the surface stress and bulk strain in a silicon crystal, Journal of Applied Crystallography 53 (5) (2020) 1195–1202. doi:10.1107/S1600576720009267.
  42. [46]D. A. Pushin, D. G. Cory, M. Arif, D. L. Jacobson, M. G. Huber, Reciprocal space approaches to neutron imaging, Applied Physics Letters 90 (22) (2007) 224104. doi:10.1063/1.2737390.DOI
  43. [47]D. A. Pushin, M. Arif, D. G. Cory, Decoherence-free neutron interferometry, Physical Review 79 (5) (2009) 053635. doi:10.1103/PhysRevA.79.053635.DOI
  44. [48]J. Jurns, M. Middleton, R. Williams, Progress towards operation of a deuterium cold neutron source at the ncnr, IOP Conference Series: Materials Science and Engineering 755 (1) (2020) 012025. doi:10.1088/1757-899X/755/1/012025.

Paper details

vlnc:W_ussgxf6h
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 0

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents