WorksPhysics and Astronomy
Confidence-Aware Discriminative Readout of Neutral-Atom Arrays
Abstract
Fast and reliable detection is a central requirement for neutral atom quantum computers, yet fluorescence imaging remains a limiting step for rapid experimental cycling, large-scale array operation, and quantum-error-correction protocols. In this work, we demonstrate confidence-aware readout of atoms in optical tweezers using a discriminative classifier. Rather than forcing each atom-site image directly into a hard binary outcome, the proposed readout produces a measurement reliability score. This score is produced by a logistic-regression classifier trained on features derived from both the total photon count and the spatial pattern of fluorescence at each site. The resulting classifier achieves the same readout fidelity with approximately half the imaging time. At an exposure of 10 ms, it achieves readout fidelity, comparable to the achieved by conventional photon-count thresholding at 20 ms. Importantly, the classifier score enables low-confidence outcomes to be converted into measurement-level erasures, leaving fewer residual unflagged errors at a fixed erasure budget. This improvement is further accompanied by strong false-positive suppression, which is important for downstream operations such as atom rearrangement where false positives can create target defects. Monte Carlo rearrangement simulations show that the reduced false-positive rate and confidence-based erasure conversion improve predicted defect-free assembly performance. This work establishes confidence-aware readout using a discriminative classifier as a practical paradigm for fast and scalable neutral-atom quantum computing.
Introduction
Among current quantum computing platforms, neutral atom architectures have emerged as promising because of their scalability and flexible connectivity [1, 2]. Nevertheless, they still face several important systems-level limitations, including relatively slow atom transport [3, 4] and fluorescence-based measurement times that remain long compared with those of physical qubit operations [5]. This measurement overhead directly constrains the cycle time of neutral atom processors. It is especially important for repeated mid-circuit measurements in fault-tolerant circuits [6, 7], rapid subarray rearrangement and state preparation in continuous-loading architectures [8, 9], and the suppression of idle errors during quantum error correction (QEC) cycles [10]. Large-scale algorithms may require continuous fault-tolerant operation over several days, while neutral atom-specific QEC and simulation architectures increasingly rely on sub-millisecond syndrome extraction, rearrangement and few-round syndrome measurements [11, 12, 13, 14]. These applications demand reliable fluorescence readout on a timescale compatible with processor’s gate operation.
The central challenge in fast fluorescence imaging is not only to maintain high binary readout fidelity with fewer detected photons, but also to preserve information about which readout decisions are reliable. Strong photon scattering can heat atoms and lead to loss, whereas reducing the measurement time decreases the photon budget and broadens the overlap between the atom-present and atom-absent signal distributions. However, conventional fluorescence readout compresses each region of interest (ROI) into a binary decision by thresholding scalar photon count values. When the readout photon budget is limited, some ROI measurements fall close to the decision boundary and therefore carry substantial uncertainty in their assigned label. Hard thresholding discards this uncertainty by returning only a binary outcome, losing information about the reliability of that outcome.
This motivates a confidence-aware readout approach, in which the readout output is not limited to a hard occupied/empty label, but also includes a scalar measure of decision reliability. The value of such soft measurement information is well established in QEC theory and has been experimentally explored most directly in superconducting qubit processors, where analog readout records can be incorporated into decoders instead of being discarded by hard thresholding [15, 16]. Related decoding ideas have also been studied for neutral atom QEC models, suggesting that fluorescence readout uncertainty can affect logical performance [17]. In neutral atom fluorescence experiments, however, image information is commonly compressed into binary occupation before being passed to downstream operations such as rearrangement, atom replacement, or reinitialization.
A key question is what kind of readout score provides useful reliability information for fluorescence readout images. To address this question, we consider two broad software-based classification: generative and discriminative methods Figure 1(a). A generative approach specifies how each class produces the observed data, for example through class-conditional image likelihoods and , where is the measured fluorescence image and and denote the atom-present and atom-absent classes. Bayes’ rule is then used to infer the posterior class probability. This approach is physically interpretable and can be data-efficient when the image-formation and noise models are accurate. Nevertheless, its performance can be limited by mismatch between the analytical model and the experimental image-distribution. A discriminative approach instead uses labeled data to learn the decision boundary between atom-present and atom-absent images directly. This can make the classifier less sensitive to misspecification of image-distribution details that are irrelevant to the classification task [18], and its performance typically improves as more representative labeled training data become available [19, 20]. Although Bayesian inference yields the optimal decision rule when the class-conditional generative model and class priors are correct [21], accurate generative modeling can be difficult in experimental settings. This motivates a discriminative readout strategy that learns the empirical occupied/empty boundary from labeled data.
Figure 1. Overview of discriminative confidence-aware readout and its use in atom rearrangement. (a) Conceptual comparison between generative and discriminative classification. A generative approach models how each class produces the measured data and uses prior information and evidence to infer the posterior class probability. A discriminative approach instead extracts features from the data and directly learns a boundary that separates the two classes. (b) Discriminative readout pipeline used in this work. From each fluorescence image, we extract scalar region-of-interest (ROI) features including raw photon count, denoised photon count, point-spread-function (PSF) template-matching score, and background-fitted camera-noise log-likelihood. These features define a multi-dimensional feature space, in which logistic regression learns the occupied/empty decision boundary. (c) Use of the confidence score for measurement-erasure conversion in atom rearrangement. Without erasure conversion, a low-confidence false-positive event can be treated as an occupied source site and lead to rearrangement failure. With erasure-aware readout, the same low-confidence event is flagged and excluded from the source pool, enabling successful rearrangement.
In this work, we demonstrate that a discriminative classifier’s output value improves both fast readout and confidence-based error flagging for neutral atom fluorescence readout images. The classifier combines physics-derived and AI-learned features, including raw photon counts, photon counts after image noise reduction, empirical spatial information, and camera-noise likelihood features Figure 1(b). Relative to conventional thresholding and a Bayesian posterior-rule baseline, the resulting score improves the empirical occupancy readout fidelity and yields approximately a reduction in the measurement time required to reach comparable readout fidelity. Beyond this improvement, the discriminative score provides more useful reliability information: when low-confidence outcomes are converted into measurement-level erasures, the classifier leaves fewer residual errors than the conventional thresholding or Bayesian baseline.
In particular, we introduce an AI-driven denoised-ROI feature that reduces class overlap and lowers false-positive rate (FPR), defined here as the probability that an atom-absent ROI is incorrectly classified as atom-present. When the denoised-ROI feature is incorporated into the multi-feature discriminative classifier, the resulting AI-assisted readout strongly suppresses false positives, reducing the FPR by more than one order of magnitude. Unlike generative image approaches such as Generative Adversarial Network (GAN)-based denoising [22], our method does not require clean target images for denoiser training and suppresses hallucinations.
These gains are directly relevant to assembly of defect-free atomic qubit arrays. During rearrangement, false-positive occupancy errors are particularly detrimental. If an empty reservoir site is falsely identified as occupied, it may be selected as an atom source, leading to an attempted move from an empty trap and leaving a defect in the target array. Confidence-based erasure mitigates this failure case by excluding ambiguous sites from the source pool before rearrangement Figure 1(c). Although increasing the readout exposure time improves classification fidelity, our simulations show that fast readout combined with confidence-based erasure can yield higher defect-free success rates than longer readout without era- sure filtering.
Overview of Experimental Setup
The imaging method used in this work follows the dual-tone narrow-line imaging scheme described in the previous work [23]. We provide a brief summary of the scheme and focus on the experimental modifications that were necessary for simultaneous acquisition of readout and reference images. We imaged atoms trapped in a shallow 759.4 nm clock-magic tweezer using dual-tone driving on the and intercombination transition at 556 nm. A tweezer array with a beam waist of 0.9 m and a trap depth of 200 K was used.
Atomic fluorescence was collected by an objective lens with numerical aperture 0.5 (Mitutoyo G Plan Apo 50×) and split equally by a 50:50 beam splitter Figure 2. One output arm was directed to an electron-multiplying CCD (EMCCD) camera (Andor iXon Ultra 897) with camera gain 300 for readout-image acquisition, while the other was directed to a qCMOS camera (Hamamatsu C15550-22UP) for reference-image acquisition. Readout and reference images were acquired simultaneously. Reference images were acquired at a fixed exposure time of 60 ms for label generation, while pairs of consecutive readout images were recorded for denoiser training at exposure times and 20 ms. The corresponding average detected photon counts per ROI were 4.45, 6.44, 8.39, 10.4, 12.33, 14.36, 16.67, and 20.77, respectively. The 60 ms reference exposure is short compared with the characteristic imaging-loss time of approximately 5.26 s.
Figure 2. Experimental setup Simultaneous acquisition of readout and reference fluorescence images of a tweezer array. Fluorescence from atoms trapped in a 759 nm optical tweezer array is collected with 556 nm imaging beam and an NA = 0.5 objective. The fluorescence is then split by a 50:50 beam splitter. One arm is directed to an electron-multiplying CCD (EMCCD) camera that acquires readout images with exposure times of 4–20 ms, while the other arm is directed to a qCMOS camera that acquires reference images with a 60 ms exposure for reference-image generation. Two consecutive readout images were acquired in the EMCCD arm for each experimental shot.
Images were acquired with a size of pixels, and each atomic site was analyzed using a ROI with pixels. The measured nearest-neighbor atom spacing was approximately 15 pixels, corresponding to a physical atom-to-atom separation of 4.8 m. For each readout exposure time, the dataset contained approximately to frames, corresponding to about to paired acquisition sets, since two readout images were recorded per set (see Appendix § 2).
Data-Driven Discriminative Readout
Data-driven discriminative readout directly learns the boundary between occupied and empty sites from labeled experimental data, rather than classifying through a fully specified pixel-level generative likelihood. In our implementation, each atom-site ROI is represented by a set of physically interpretable scalar features, and a logistic-regression classifier combines these features to produce an atom-present probability. Specifically, we extract (i) pixel-value-based, (ii) denoising-derived pixel-value-based, (iii) background-fitted camera-noise-model-based, and (iv) point-spread-function (PSF)-based features from the measured images and use them as inputs to a logistic-regression classifier.
The feature set used in the final classifier was selected by systematically evaluating a broad set of candidate descriptors, retaining only the most informative descriptors. The proposed framework is not restricted to the four features considered here; in principle, any physically or statistically motivated descriptor of the ROI can be incorporated into the discriminative classifier. We therefore examined additional candidates, including the fraction of atomic signal concentrated near the ROI center, the similarity between the denoiser-learned noise model and the observed noise, and residual spatial structure after subtracting a fitted PSF model from the ROI. Feature-addition analysis showed that these additional descriptors produced only small changes beyond the selected four features (see Appendix § 10.2 for their definitions and Table D3 for the results). Nevertheless, the framework remains extensible, and future studies may identify more informative descriptors that further improve classification performance or provide additional physical interpretability.
| Exp. (ms) | Added candidate | [95% CI] | ||
| 4 | Center concentration | 0.000 [-0.050, +0.050] | +0.117 | -0.029 |
| 4 | Learned noise score | +0.006 [-0.013, +0.025] | -0.021 | -0.003 |
| 4 | PSF residual structure | +0.025 [-0.011, +0.061] | -0.032 | -0.024 |
| 5 | Center concentration | +0.014 [-0.032, +0.059] | +0.022 | -0.073 |
| 5 | Learned noise score | 0.000 [-0.045, +0.050] | +0.022 | -0.036 |
| 5 | PSF residual structure | -0.005 [-0.036, +0.023] | -0.007 | +0.024 |
| 8 | Center concentration | -0.004 [-0.029, +0.018] | -0.009 | +0.013 |
| 8 | Learned noise score | +0.004 [-0.007, +0.018] | +0.009 | -0.013 |
| 8 | PSF residual structure | +0.015 [-0.004, +0.037] | -0.017 | -0.013 |
| 10 | Center concentration | -0.004 [-0.018, +0.007] | 0.000 | +0.006 |
| 10 | Learned noise score | +0.004 [0.000, +0.011] | 0.000 | -0.006 |
| 10 | PSF residual structure | +0.004 [-0.007, +0.014] | -0.009 | 0.000 |
| 12 | Center concentration | 0.000 [0.000, 0.000] | 0.000 | 0.000 |
| 12 | Learned noise score | -0.007 [-0.018, 0.000] | +0.013 | +0.005 |
| 12 | PSF residual structure | 0.000 [-0.022, +0.018] | +0.013 | -0.005 |
| 14 | Center concentration | 0.000 [0.000, 0.000] | 0.000 | 0.000 |
| 14 | Learned noise score | 0.000 [0.000, 0.000] | 0.000 | 0.000 |
| 14 | PSF residual structure | 0.000 [0.000, 0.000] | 0.000 | 0.000 |
| 16 | Center concentration | +0.004 [0.000, +0.011] | 0.000 | -0.005 |
| 16 | Learned noise score | +0.004 [0.000, +0.011] | 0.000 | -0.005 |
| 16 | PSF residual structure | -0.004 [-0.011, 0.000] | 0.000 | +0.005 |
| 20 | Center concentration | -0.004 [-0.011, 0.000] | 0.000 | +0.006 |
| 20 | Learned noise score | 0.000 [0.000, 0.000] | 0.000 | 0.000 |
| 20 | PSF residual structure | -0.004 [-0.011, 0.000] | +0.009 | 0.000 |
Table D3. Additional candidate features added to the selected 4D-LR classifier. Each row adds only the indicated scalar or descriptor group to the same four features. Changes are defined as augmented minus baseline performance: , , and . All values are in percentage points; positive indicates improvement, whereas positive rate changes indicate increased errors. Brackets give paired 95% percentile confidence intervals for , using 5,000 frame-bootstrap draws with the same sampled frames for both classifiers. The baseline out-of-fold decisions exactly match those used in the main analysis at all eight measurement times.
In this section, we describe the selected features and the logistic-regression model. We then analyze the resulting fidelity improvements and quantify the contribution of each feature. We benchmark our approach against two representative readout strategies: a conventional method which detects site occupancy based on thresholding of detected photon counts [24], and an EMCCD noise-based Bayesian readout model following Martinez-Dorantes et al. [25] (see Appendix § 2.1).
Feature description and logistic regression
We selected four features that capture complementary aspects of the measured image. For each atom site , we define a ROI centered at the calibrated site position , . Here indexes camera pixels. The raw image in experimental shot is denoted by , in analog-to-digital units (ADU), and the output of the trained denoiser is denoted by . Background images are obtained from separate frames acquired before loading atoms in traps. We denote the corresponding raw and denoised background frames by and , where indexes background frames. The mean raw and denoised backgrounds are , . We construct the following four scalar features from each ROI.
a. Photon count in raw image. The first feature is the total background-subtracted raw signal within the ROI,
where converts ADU counts into detected photoelectrons after EM gain correction. This feature estimates the total photon signal collected from the atom image. We use the camera sensitivity and EM gain , giving .
b. Photon count in denoised image. The second feature applies the same summation to the denoised image Figure 3(a),
Figure 3. Denoising reduces photon-count variance in fast measurements. (a) Representative raw and denoised readout images at . Denoising suppresses camera/background fluctuations while preserving the atom fluorescence spots. (b) Raw-photon-count versus denoised-photon-count distribution at , with histograms for atom-absent and atom-present ROIs. The denoised photon count preserves the photon scale of atom-present ROIs while reducing the variance of the signal distributions for both atom-absent and atom-present ROIs, thereby reducing overlap between the two classes.
This feature captures the atom-like signal after noise suppression by the trained denoiser. The denoising architecture is adapted from the Noise2NoiseFlow framework [26, 27], which enables training without clean target images. We use two consecutively acquired images as paired noisy observations for denoiser training. Specifically, we write the two images as and , where denotes the underlying fluorescence signal that is common to the pair, and and denote the independent noise contributions in the two images. First, the images are denoised using a DnCNN module [28] which learns to remove noise by generating a clean-image estimate. The residual noise is then modeled by a normalizing-flow noise model [29, 30] followed by DnCNN, which explicitly learns an invertible probability density function for the noise distribution. This allows the camera-noise statistics to be learned from data rather than imposed through a hand-crafted parametric model.
For our fluorescence data, we increased and optimized the depth of the DnCNN-based denoising module and simplified the flow-based noise model. Further details of the architecture and the optimized loss function are provided in Appendix E. As shown in Figure 3(b), denoising reduces the variance of the signal distributions for both atom-present and atom-absent ROIs. This variance reduction suppresses false-positive events, as reflected in Figure 4(b) and Table C2.
Figure 4. Readout fidelity and false-positive suppression. (a) Readout infidelity as a function of measurement time for conventional thresholding on raw images (RAW-1D), two-feature logistic regression using two features (the raw ROI photon count and background-fitted camera-noise-model likelihood) (2D-LR), four-feature logistic regression (4D-LR), and the Bayesian baseline. The discriminative classifiers, 2D-LR and 4D-LR, provide the largest gains in the low-photon regime. (b) False-positive rate (FPR) for the readout methods, including conventional thresholding on denoised images (DEN-1D). The denoised-ROI feature substantially lowers false-positive errors relative to RAW-1D and the Bayesian baseline. Shading denotes pointwise 95% confidence intervals from 5,000 frame-bootstrap resamples of fixed out-of-fold predictions. Bayes: Bayesian baseline adapted from Martinez-Dorantes et al. [25].
| Meas. (ms) | Mean Photon | RAW-1D FPR (%) | RAW-1D FNR (%) | DEN-1D FPR (%) | DEN-1D FNR (%) | Bayes [25] FPR (%) | Bayes [25] FNR (%) | 2D-LR FPR (%) | 2D-LR FNR (%) | 4D-LR FPR (%) | 4D-LR FNR (%) |
| 4 | 4.45 | 12.56 | 4.78 | 9.14 | 4.02 | 21.26 | 0.94 | 11.62 | 2.78 | 9.06 | 2.44 |
| 5 | 6.44 | 1.97 | 4.01 | 0.93 | 3.80 | 2.71 | 0.80 | 1.01 | 3.11 | 0.70 | 2.57 |
| 8 | 8.39 | 1.98 | 0.87 | 0.91 | 0.79 | 1.72 | 0.16 | 0.54 | 0.72 | 0.31 | 0.47 |
| 10 | 10.40 | 1.52 | 0.23 | 0.74 | 0.20 | 1.22 | 0.05 | 0.25 | 0.30 | 0.12 | 0.21 |
| 12 | 12.33 | 1.49 | 0.06 | 0.85 | 0.04 | 1.04 | 0.01 | 0.13 | 0.10 | 0.14 | 0.06 |
| 14 | 14.36 | 1.14 | 0.01 | 0.39 | 0.01 | 0.51 | 0.00 | 0.07 | 0.06 | 0.01 | 0.03 |
| 16 | 16.67 | 0.92 | 0.00 | 0.07 | 0.02 | 0.32 | 0.00 | 0.05 | 0.06 | 0.02 | 0.04 |
| 20 | 20.77 | 0.47 | 0.00 | 0.10 | 0.00 | 0.23 | 0.00 | 0.04 | 0.01 | 0.04 | 0.01 |
Table C2. False-positive and false-negative rates. FPR and FNR values are reported in percentage. RAW-1D: Conventional thresholding in raw image; DEN-1D: Conventional thresholding in denoised image; Bayes: Bayesian baseline adapted from Martinez-Dorantes et al. [25]. 2D-LR: two-dimensional logistic regression using raw-image features; 4D-LR: four-dimensional logistic regression;
c. PSF template-matching score. The third feature measures whether the spatial distribution of counts within the background-subtracted ROI is consistent with an empirically measured single-atom image. Here, the term point-spread-function (PSF) does not refer to a fitted Gaussian or Airy model. Instead, we construct an empirical atom-image template directly from atom-present images identified using the reference imaging arm. We then define a normalized template-matching score, mathematically equivalent to the Pearson correlation between the background-subtracted ROI and this empirical template [31]. For each training fold, the empirical template is obtained by averaging background-subtracted ROIs over all atom-present samples,
where is the number of atom-present training samples and denote the reference label where indicating an atom-present sample and indicating an atom-absent sample. After averaging, negative values are clipped and the template is normalized to unit sum. The PSF feature is then defined as the Pearson correlation between the background-subtracted ROI and the empirical template,
The overbar denotes the mean and denotes the Euclidean norm over pixels over the ROI. This feature is designed to contribute spatial-shape information. It measures whether the detected signal is distributed like a single-atom fluorescence image.
d. Background-fitted camera-noise log-likelihood. This feature describes the similarity between the image’s pixel distribution and EMCCD’s noise distribution. Noise distribution is modeled by combining electron-multiplication statistics, readout noise, and clock-induced-charge contributions [32, 33]. For the likelihood feature, the camera model parameters are estimated from background images, yielding . We then define a background-fitted EMCCD log-likelihood feature as
Smaller values of indicate that the observed ROI pixels are less compatible with the EMCCD noise distribution fitted to background images and are therefore more likely to contain atom fluorescence. The detector-output likelihood feature is implemented here using an analytical EMCCD output-noise model, because the detector response is well characterized and this feature gave the best validation performance in our data.
e. Logistic-regression Classifier We use logistic regression as a simple discriminative model that assigns learned weights to the four features and maps their weighted sum to an atom-present probability. Before fitting the logistic-regression classifier, each feature is standardized using the mean and standard deviation computed from the training samples in the corresponding cross-validation fold,
The standardized vector defines a point in a four-dimensional feature space, where each dimension corresponds to one scalar image descriptor. This vector is used as the input to the logistic-regression classifier. The atom-present probability is modeled as
where . Let denote the bias term and the feature-weight vector. The weights are obtained by minimizing the L2-regularized cross-entropy loss,
where denotes the training set. The final binary prediction is obtained using a fixed threshold, . All preprocessing steps, including the PSF-template construction, feature standardization, and classifier fitting, are performed independently within each training fold. Reported performance metrics are computed from out-of-fold predictions.
Fidelity improvement and error analysis
We next quantify how the discriminative feature representation improves readout performance relative to one-dimensional thresholding [24] and the Bayesian baseline [25]. Because the total fidelity alone can obscure the underlying error mechanism, we also separately analyze the false-positive rate (FPR) and false-negative rate (FNR) [Fig.4]. Complete fidelity, FPR, and FNR values across all measurement times are provided in Appendix C.
The full four-feature classifier (4D-LR) combines complementary information from photon counts, denoised intensity, camera-noise likelihood, and empirical spatial structure to improve readout fidelity, with the largest absolute gains in the fast imaging regime () [Fig.4(a)]. At 10 ms, it achieves 99.83% fidelity, comparable to the 99.82% obtained by RAW-1D at 20 ms, demonstrating an approximately twofold reduction in the measurement time needed to reach this fidelity level. It also exceeds 99.9% fidelity for all measurement times from 12 ms onward.
The improvement also changes the error profile, substantially reducing false-positive decisions [Fig.4(b)]. At 10 ms, 4D-LR reduces the FPR to 0.12%, compared with 1.52% for RAW-1D and 1.22% for the Bayesian baseline.
Relative to the Bayesian baseline, this suppression comes with a higher FNR, illustrating why total fidelity alone does not fully characterize readout performance.
Comparisons with simpler readout methods help explain the gain. A two-feature classifier (2D-LR), using the raw photon count and camera-noise log-likelihood, already improves on RAW-1D and the Bayesian baseline, while thresholding denoised images (DEN-1D) primarily suppresses false positives. The detailed error-rate comparisons are provided in Appendix § 9.
These results highlight the practical advantage of learning the decision boundary directly from experimental data. Although a Bayesian decision rule minimizes classification error when the class-conditional distributions and priors are correctly specified, accurately modeling these distributions can be challenging in experiments. Our discriminative approach achieves higher empirical fidelity than the implemented Bayesian baseline without requiring a complete generative description of the observed images.
To quantify the contribution of each feature to 4D-LR, we remove one feature at a time from the full classifier (Table I). At 8 ms, removing the camera-noise log-likelihood produces the largest fidelity degradation, followed by the raw photon count. Removing the denoised photon count causes the largest increase in FPR, highlighting its role in suppressing false-positive decisions. The PSF-template feature provides a smaller but measurable fidelity gain. These results support combining complementary features to improve both readout fidelity and the error profile. Results at each measurement time and the feature-buildup analysis are provided in Appendix § 10.
| Removed feature | (pp) | FPR (pp) |
| Raw Photon Count | 0.070 | 0.026 |
| Denoised Photon Count | 0.062 | 0.060 |
| PSF-template correlation | 0.059 | 0.009 |
| Camera-noise log-likelihood | 0.140 | 0.051 |
Table I. Leave-one-feature-out ablation analysis of the 4D-LR classifier. Ablation results are evaluated at ms. Each feature is removed from the full model one at a time. Positive indicates fidelity degradation, and positive FPR indicates an increase in false-positive rate. Changes are reported in percentage points (pp). The largest value in each column is shown in bold.
Confidence-aware measurement erasure conversion
Conventional atom readout typically converts each ROI into a binary decision, even when the measured signal lies close to the decision boundary. However, for downstream applications such as erasure-aware error correction or atom-array assembly, it can be more useful to explicitly flag an ambiguous measurement as uncertain than to force it into an incorrect binary assignment. We therefore evaluate whether the scalar readout output value can also be used to identify decisions that are likely to be wrong.
Let denote the scalar readout score, where for probabilistic classifiers and for the thresholding methods, where is the ROI sum, and the threshold and scale are determined from the training fold. We define the confidence as the distance from the corresponding decision threshold, , where . Thus, near-threshold decisions are treated as more uncertain and can be flagged as erasures. This is analogous to using soft measurement information in quantum error correction, where the magnitude of a likelihood or posterior score quantifies the reliability of a measured bit [15]. It is also connected to erasure-conversion strategies, in which leakage-detected events are converted into located erasures rather than left as unflagged errors [34, 35].
Let denote the set of all ROI decisions at a given exposure time before erasure filtering. We rank these decisions by increasing confidence and flag the lowest-confidence decisions as erasures. The erasure budget is the fraction of all decisions flagged, where is the set of flagged decisions. Let denote the corresponding set of non-erased ROI decisions and denote the set of readout errors. At each erasure budget , the residual error rate is the fraction of non-erased decisions that are incorrect,
The upper panels of Figure 5 show how the residual error rate varies with the erasure budget .
Figure 5. Confidence-aware measurement erasure conversion. Upper panels: residual unflagged error rate as a function of the erasure budget , shown for representative measurement times. ROIs are ranked by increasing decision confidence, and the lowest-confidence fraction is flagged as erasures. Insets show the normalized residual error rate . Lower panels: error-detection ROC curves obtained by varying the confidence cutoff. The horizontal axis is the percentage of correct readouts (TP+TN) flagged as erasures, and the vertical axis is the percentage of readout errors (FP+FN) flagged as erasures. Each denominator is the corresponding total before erasure filtering. Curves closer to the upper-left corner capture more errors while flagging fewer correct outcomes. Shaded bands denote pointwise 95% confidence intervals obtained from 3,000 paired bootstrap resamples of acquisition frames, retaining all nine ROI outcomes within each frame and keeping the out-of-fold predictions fixed.
The lower panels of Figure 5 compare error detection at a matched cost of flagging correct readouts. With denoting the set of correct readouts, the horizontal and vertical axes give the fractions of correct and incorrect readouts flagged as erasures, respectively,
Higher error capture at a given correct-readout erasure rate indicates better separation of errors from correct decisions.
The value of the readout score lies not only in the accuracy of its hard decisions, but also in its ability to identify which decisions are likely to be wrong. Figure 5 shows that 4D-LR provides both advantages. It leaves the lowest residual unflagged error rate over the tested erasure budgets, while its more rapidly decreasing normalized curves indicate that low-confidence outcomes capture a larger fraction of its initial errors. The benefit therefore extends beyond higher readout fidelity to more effective identification of unreliable decisions. This allows a limited erasure budget to be used more effectively, reducing the errors that remain unflagged.
Improved Atom Rearrangement via Measurement Erasure
Atom rearrangement provides a direct application of confidence-aware readout, because successful assembly depends on the reliability of the sites selected as atom sources. A false-positive decision can cause an empty site to be selected, leaving a defect in the target array, whereas a false-negative decision mainly reduces the available atom pool. This asymmetry motivates using measurement confidence to exclude uncertain occupied-site predictions before rearrangement. Such erasure-aware source selection can reduce incorrect source assignments, provided that enough atoms remain to fill the target.
We quantified this effect using Monte Carlo simulations. Atoms were initialized on a reservoir array with loading probability , and the rearrangement algorithm was applied to fill a square target array. The measured false-positive and false-negative rates were used as simulation inputs and imaging-induced atom loss was included using with .
We evaluated both single-round and multi-round rearrangement, defining the success rate as the fraction of Monte Carlo trials that achieve defect-free assembly under each protocol. In the single-round protocol, success requires filling a fixed target after one readout-and-move cycle, without an additional readout or refill within that round. In the multi-round protocol, up to 20 cycles are allowed, with the target size adjusted in each round according to the number of detected candidate atoms. After each failed round, only atoms remaining in the attempted target region are retained for the next round; unused reservoir atoms are discarded and not reused. Success requires obtaining a defect-free array of at least within the allowed number of rounds, so specifies the minimum target size in this protocol. For the erasure-aware methods, low-confidence sites classified as occupied are excluded from the source pool before each move. The rearrangement algorithm and simulation procedure are described in Appendix F.
Confidence-aware source selection improves defect-free assembly in both multi-round and single-round rearrangement. For a minimum target size of , 4D-LR with erasure-aware selection achieves multi-round success rates above 90% for Figure 6(a). At 10 ms, erasure-aware selection increases the predicted multi-round success rate from 88.09% to 98.44%. Its advantage is particularly clear when only one rearrangement cycle is allowed. The 4D-LR-based methods are the only methods that yield substantial success at 8–12 ms Figure 6(b), where incorrect source assignments cannot be corrected by subsequent readout and rearrangement. At 10 ms, erasure-aware selection increases the predicted single-round success rate from 59.87% to 96.37%, compared with 4.90% for DEN-1D, 0.86% for the Bayesian baseline, and 0.22% for RAW-1D.
Figure 6. Confidence-aware readout and measurement erasures improve atom rearrangement. (a) Multi-round success rate as a function of measurement time , with a minimum target size of . Simulations start from a reservoir array with loading probability . 4D-LR with erasure-aware source selection achieves success rates above 90% for ms. (b) Single-round success rate as a function of measurement time for a fixed target. The 4D-LR-based methods are the only methods that yield substantial single-round success at 8–12 ms. At 10 ms, the success rate rises from 59.87% without erasure filtering to 96.37% with it. (c) Single-round success rate of 4D-LR as a function of erasure budget for a fixed target. For each exposure, the star marks the smallest erasure budget whose success rate is within one Monte Carlo standard error of the maximum found in the sweep over budgets up to 25%. The displayed window shows 8–20 ms, erasure budgets of 0–3%, and success rates of at least 50%. Stars are shown only when the selected points fall within this window. Shorter readout exposures with confidence-based source selection can outperform longer readout exposures without source filtering: single-round 4D-LR achieves 96.37% at 10 ms with erasure filtering, versus 85.53% at 20 ms without it.
The dependence on erasure budget reveals a balance between source reliability and atom availability. Rejecting uncertain candidates reduces false source assignments, but excessive rejection leaves too few atoms to fill the target Figure 6(c). At an appropriate erasure budget, shorter readout exposures with confidence-based selection can outperform longer readout exposures without source filtering. For example, single-round 4D-LR at 10 ms with erasure filtering achieves 96.37% success, compared with 85.53% at 20 ms without erasure filtering.
Discussion
Our Bayesian baseline uses a physics-based likelihood model that explicitly accounts for photon counting, camera noise, and atom loss. Its performance depends on how accurately this model describes the fluorescence images for occupied and empty sites.
With correctly specified class-conditional likelihoods and priors, assigning each image to the class with the higher posterior probability minimizes the expected classification error. The higher readout fidelity of 4D-LR and its more effective identification of readout errors suggest room to refine the likelihood model used in our Bayesian baseline. The features used by 4D-LR suggest concrete tests of the Bayesian likelihood model. For example, comparing simulated and measured images of empty sites could reveal whether the model reproduces the frequency of background fluctuations that resemble an atomic fluorescence spot.
One possible extension is therefore to retain the physical likelihood model as the readout backbone while using calibration images to adjust the final occupied/empty decision rule. Such a hybrid strategy [20] would preserve the interpretability and data efficiency of the Bayesian model while correcting systematic decision biases caused by experimental effects not fully captured in the analytical likelihood model.
The feature-based structure of discriminative classifier makes the framework naturally extensible. More systematic feature discovery may reveal additional informative observables, and such observables could in turn guide improved generative modeling of the Bayesian likelihood. A particularly promising direction is to use temporal information, such as photon-arrival statistics or shot-to-shot intensity dynamics, which may provide information beyond the spatial ROI features considered here.
Several aspects are compatible with future experimental deployment. First, the denoising architecture does not rely on a specific model of the measurement device. It learns the camera-noise distribution from paired noisy images and can therefore be adapted to other fluorescence-imaging systems once appropriate training data are available. Such a variant would allow the logistic-regression classifier to operate without an explicitly defined camera-output model, which opens a route toward a camera model-agnostic readout pipeline. Second, inference latency can be reduced in several ways. Because the dominant computational component is the convolutional denoiser, the pipeline is well suited to hardware acceleration. Recent work has demonstrated FPGA-accelerated convolutional-neural-network (CNN) inference for fluorescence-based qubit readout [36]. Neural processing units (NPUs) with tensor-oriented architectures [37] can also efficiently execute neural-network inference workloads. Further reductions in memory traffic and latency may be obtained using standard neural-network compression techniques such as integer quantization and pruning [38, 39, 40]. Our inference method reduces the number of detected photons needed to reach a given readout fidelity. Imaging could be made faster still by collecting those photons at a higher rate. For example, in our current setup, a 50:50 beam splitter diverts half of the collected fluorescence to a qCMOS camera for simultaneous reference imaging. Once the classifier has been trained and validated, the splitter could be removed for routine readout, approximately doubling the fluorescence photon flux reaching the EMCCD. This would yield a similar photon count in roughly half the exposure time and could allow comparable readout fidelity. Further improvements, such as a higher numerical aperture, a higher scattering rate, or more efficient cooling, could help achieve faster imaging with high atom survival. In quantum error correction, shorter readout times can reduce idle errors on data qubits during measurement [10, 41], while confidence-based erasure conversion can aid decoding by flagging unreliable measurement outcomes as erasures [34]. Together, these effects can lower the logical error rate. A systematic study of the trade-off between imaging time, measurement fidelity, erasure budget, and the number of measurement rounds remains an important direction for future work.
Conclusion
We demonstrated confidence-aware fluorescence readout of individual atoms in optical tweezers using a feature-based discriminative classifier. By combining raw and denoised photon counts, a PSF-template correlation score, and a background-fitted camera-noise log-likelihood, the logistic-regression model learns the occupied/empty decision boundary directly from labeled experimental data. This formulation retains physically motivated information while learning the decision rule without requiring complete class-conditional likelihood models for the fluorescence images.
In the evaluated dataset, the four-feature classifier achieved higher occupancy-readout fidelity than conventional photon-count thresholding and the implemented Bayesian baseline. At an imaging exposure of 10 ms, it reached 99.83% fidelity, comparable to the 99.82% obtained by conventional thresholding at 20 ms. At this operating point, the classifier thus achieved comparable fidelity at half the exposure used by the threshold baseline. The improvement was accompanied by substantial suppression of false-positive decisions.
Beyond improved binary classification, the classifier score also provides useful information about the reliability of individual readout outcomes. Flagging low-confidence outcomes as measurement-level erasures leaves fewer residual unflagged errors than the threshold and Bayesian baselines at matched erasure budgets. For atom rearrangement, this information enables uncertain occupied-site predictions to be excluded from the source pool. Monte Carlo simulations parameterized by the measured error rates predict improved defect-free assembly through this confidence-based source selection. These results illustrate how readout confidence and the unequal consequences of false-positive and false-negative decisions can be used in downstream operations such as atom rearrangement.
The feature-based formulation is naturally extensible. Additional physically or statistically motivated descriptors can be incorporated and evaluated for a given imaging system or downstream task. This flexibility allows the readout model to be refined as new experimentally informative features are identified. Our framework thus provides a practical basis for combining accurate occupancy discrimination with confidence-guided atom selection, and for investigating its use in larger arrays and future mid-circuit measurement protocols.
ACKNOWLEDGMENTS
We thank Kangjin Kim, JuYoung Park, Sunhwa Hwang, and Seungtaek Oh for helpful discussions. This work was supported by the National Research Foundation of Korea(NRF) under Grant No. RS-2025-25464182, RS-2023-NR119928, and RS-2023-00283259.
Data Preparation and Cross-Validation Protocol
For supervised evaluation, we used the qCMOS reference image to label each site as occupied or empty. The EMCCD readout and qCMOS reference images were acquired simultaneously, with exposure times of 4–20 ms and 60 ms, respectively. An atom that fluoresces early in the exposure and is then lost or stops scattering can produce enough signal to be detected in the short readout image, yet leave too little integrated signal to cross the threshold for an occupied site in the reference image. We flagged frames containing at least one site labeled empty in the qCMOS reference for which the background-subtracted ROI signal in the EMCCD image exceeded threshold. We visually inspected the flagged frames and retained frames identified as EMCCD false positives and excluded the remaining flagged frames in their entirety. We additionally excluded acquisition sets in which no atoms were detected at any site of the array, because fully empty images were empirically found to degrade denoising-model training.
Table A1 summarizes the number of acquired frames, the number of test frames remaining after filtering, and the atom-loading fraction in the filtered test set. The loading fraction was computed as the number of atom-present sites divided by the total number of analyzed sites in the filtered test set. These loading fractions were also used when reporting the prior-weighted readout fidelity defined in the main text.
| Exp. (ms) | Total frames | Test frames | Filtered test frames | Loading rate (%) |
| 4 | 30,000 | 5,357 | 5,284 | 80.28 |
| 5 | 13,770 | 2,458 | 2,444 | 37.61 |
| 8 | 15,952 | 3,190 | 3,024 | 56.78 |
| 10 | 15,986 | 3,197 | 3,084 | 59.09 |
| 12 | 16,000 | 3,200 | 3,073 | 71.37 |
| 14 | 16,000 | 3,200 | 3,099 | 73.99 |
| 16 | 15,994 | 3,198 | 3,128 | 66.35 |
| 20 | 15,996 | 3,199 | 3,098 | 60.72 |
Table A1. Data split, filtering, and loading fraction. Total frames denote the number of acquired EMCCD readout images for each measurement time. The data were split into training, validation, and test sets using a 6:2:2 ratio. Filtered test frames denote the number of test frames remaining after excluding fully empty acquisition sets and samples with label-inconsistent atom appearance between the readout and reference images. The loading rate is computed from the filtered test set as the fraction of atom-present sites among all analyzed sites. This loading rate varies because each measurement-time condition was acquired in an independent experimental run.
We evaluated all methods on the same filtered frames using five-fold cross-validation. In each split, we used four folds to fit the readout method and its preprocessing parameters, then applied them to the fifth fold. The Noise2NoiseFlow denoiser was fixed across all folds. We computed all classification metrics from the held-out predictions.
Readout Baselines and Evaluation Metrics
Threshold baseline
As a conventional baseline, we use a thresholding method based on the ROI-integrated signal , where denotes the gain-calibrated pixel value at ROI coordinate . The signal distributions for atom-absent and atom-present ROIs are modeled from ground-truth-labeled samples, with the atom-absent distribution represented by a Gaussian peak and the full-exposure atom-present signal distribution represented by a Gaussian peak with separately estimated mean and variance. Atom loss during the imaging is incorporated by writing the signal distribution for initially occupied sites as a survival-loss mixture,
where is a exponential decay tail describing atoms that emit only a fraction of the full-exposure signal before being lost. The survival probability is approximated to first order as
For each measurement time condition, the classification threshold is chosen to maximize the prior-weighted fidelity,
where is the empirical atom-loading rate derived from the training data.
Bayesian baseline
As a physics-based baseline method, we implemented a Bayesian readout model following Martinez-Dorantes et al. [25]. Given an observed signal value and occupancy class , the posterior is obtained from Bayes’ theorem,
In our implementation, the class-conditional likelihood explicitly incorporates class-dependent photon-emission statistics including leakage, Poissonian clock-induced charge (CIC), stochastic EM-gain amplification, and Gaussian readout noise. In particular, the total electron-count distribution is modeled as a convolution of the class-dependent photon distribution with a Poisson CIC process, and the resulting camera response is modeled by an Erlang amplification distribution convolved with Gaussian readout noise. Atom loss during imaging is incorporated as a survival-loss mixture in the atom-present likelihood, using the measured loss rate to model the fluorescence duration shared by all ROI pixels. Pixel likelihoods are multiplied conditional on that duration before integrating over the common loss time. The camera-noise parameters remain fixed at their calibration values. The prior probabilities were estimated from the training partition of each cross-validation split. Specifically, was set to the atom-present fraction in the training labels, and . These priors were then held fixed when evaluating the Bayesian posterior on the corresponding held-out test fold.
Unlike the original column-by-column formulation of Ref. [25], our geometry permits direct inference on a fixed two-dimensional ROI around each site, since the nearest-neighbor spacing is much larger than the imaging PSF width. We therefore perform pixel-by-pixel Bayesian inference within each ROI, using the mean atom-present image measured within each training fold as a PSF-like two-dimensional signal template. The resulting posterior log-probability is then thresholded to obtain the Bayesian discriminator.
Evaluation metrics
Throughout this work, readout fidelity is evaluated directly from the confusion matrix against reference labels, rather than estimated from parametric fits to the observed count distributions. Let denote the atom-loading fraction, the atom-present readout fidelity, and the atom-absent readout fidelity. We then define the total fidelity as
and the corresponding infidelity as
where is a loading fraction. All reported classification metrics were evaluated under cross-validation. In particular, unless otherwise noted, thresholds and supervised classifiers were determined on the training folds and then applied to test folds under 5-fold cross-validation. All nine sites in an acquisition frame belong to the same fold. Statistical uncertainties are pointwise 95% percentile intervals from bootstrap resampling of whole frames with the out-of-fold predictions held fixed: 5,000 resamples for fidelity and error rates, and 3,000 paired resamples for erasure curves. Here, , , and .
Detailed Readout Metrics
For completeness, Table C1 and Table C2 report the readout fidelity and the corresponding false-positive and false-negative rates, respectively, for all methods across the full range of measurement times. These numerical results supplement the trends shown in Figure 4 and support the comparisons discussed in the main text.
| Meas. (ms) | Mean Photon | RAW-1D Fid. (%) | DEN-1D Fid. (%) | Bayes [25] Fid. (%) | 2D-LR Fid. (%) | 4D-LR Fid. (%) |
| 4 | 4.45 | 93.68 [93.63, 93.90] | 94.97 [94.76, 95.16] | 95.05 [94.85, 95.25] | 95.47 [95.29, 95.66] | 96.25 [96.08, 96.42] |
| 5 | 6.44 | 97.26 [97.04, 97.47] | 97.99 [97.81, 98.17] | 98.01 [97.82, 98.19] | 98.20 [98.02, 98.37] | 98.60 [98.44, 98.75] |
| 8 | 8.39 | 98.65 [98.51, 98.78] | 99.16 [99.04, 99.27] | 99.17 [99.06, 99.28] | 99.36 [99.27, 99.45] | 99.60 [99.51, 99.67] |
| 10 | 10.40 | 99.24 [99.13, 99.34] | 99.58 [99.51, 99.66] | 99.47 [99.39, 99.56] | 99.72 [99.65, 99.78] | 99.83 [99.78, 99.87] |
| 12 | 12.33 | 99.53 [99.45, 99.61] | 99.73 [99.67, 99.79] | 99.70 [99.63, 99.76] | 99.90 [99.86, 99.93] | 99.92 [99.88, 99.95] |
| 14 | 14.36 | 99.69 [99.62, 99.76] | 99.89 [99.85, 99.93] | 99.87 [99.82, 99.91] | 99.94 [99.90, 99.96] | 99.97 [99.95, 99.99] |
| 16 | 16.67 | 99.69 [99.63, 99.75] | 99.96 [99.94, 99.99] | 99.89 [99.85, 99.93] | 99.94 [99.91, 99.97] | 99.97 [99.94, 99.99] |
| 20 | 20.77 | 99.82 [99.77, 99.86] | 99.96 [99.94, 99.98] | 99.91 [99.87, 99.94] | 99.98 [99.96, 99.99] | 99.98 [99.96, 100.00] |
Table C1. Readout fidelity. Entries are fidelity [95% CI], in percent. Intervals use 5,000 whole-frame bootstrap resamples of fixed out-of-fold predictions. Bold values mark the highest fidelity at each measurement time. RAW-1D: Conventional thresholding in raw image; DEN-1D: Conventional thresholding in denoised image; Bayes: Bayesian baseline adapted from Martinez-Dorantes et al. [25]. 2D-LR: two-dimensional logistic regression using raw-image features; 4D-LR: four-dimensional logistic regression;
At the fixed decision thresholds used in this work, 2D-LR achieves higher readout fidelity than both RAW-1D and the Bayesian baseline across all measurement times. The improvement is largest in the fast readout regime ( ms), where the signal distributions for atom-present and atom-absent ROIs strongly overlap and residual mismatch in the generative model is expected to have the strongest effect.
For DEN-1D, the same one-dimensional thresholding procedure used for RAW-1D is applied after image denoising. DEN-1D reaches a fidelity comparable to the Bayesian baseline, suggesting that image-domain noise suppression can recover a large part of the gain obtained by explicit camera-noise modeling. Its error profile is different, however, as denoising mainly suppresses false positives. At 4 ms, for example, the FPR decreases from 12.56% with RAW-1D to 9.14% with DEN-1D.
The full four-dimensional feature set further improves the decision boundary. The largest absolute fidelity gains occur in the fast imaging regime, where classification errors are dominated by overlap between the atom-present and atom-absent signal distributions. For ms, the baseline fidelity is already close to unity and the remaining room for improvement is small. Nevertheless, 4D-LR exceeds 99.9% fidelity from 12 ms onward. Its 99.83% fidelity at 10 ms is comparable to the 99.82% reached by RAW-1D at 20 ms, supporting the measurement-time reduction discussed in the main text.
The Bayesian baseline tends to classify ambiguous sites as occupied, suppressing false negatives at the cost of a relatively high FPR. This behavior is particularly clear at 4 ms, where its FNR is 0.94% but its FPR is 21.26%. By contrast, 4D-LR reduces the FPR to 9.06% while keeping the FNR at 2.44%. The corresponding FPR reduction of 12.20 percentage points is accompanied by a smaller FNR increase of 1.50 percentage points. Across the full measurement-time range, 4D-LR consistently has a lower FPR and a higher FNR than the Bayesian baseline (Table C2).
4D-LR ABLATION STUDY
Ablation of the selected four features
To identify the contribution of each feature in the 4D-LR classifier, we performed two complementary ablation analyses. First, we performed a leave-one-feature-out study, in which each feature was removed from the full 4D-LR classifier. This complementary analysis quantifies how much the final classifier depends on each feature after all feature correlations have been taken into account. Second, we carried out a feature-buildup study, starting from the raw photon count feature and sequentially adding the background-fitted EMCCD log-likelihood, the denoised photon count feature, and the PSF template-matching score. This analysis shows how each additional feature improves the classifier when combined with the features already included.
Table I in the main text summarizes the reported changes in fidelity and FPR at ms, and Table D1 provides the results at each measurement time, including changes in FNR. The leave-one-feature-out analysis quantifies the contribution of each physics- or AI-derived feature to the full classifier. The camera-noise log-likelihood generally has the largest effect on fidelity for ms, while denoised intensity has a clear role in false-positive suppression. Removing the PSF template also causes a measurable fidelity loss, although its effect is generally smaller than that of the camera-noise likelihood. Because feature-buildup results depend on the order in which features are added, we treat that analysis as an interpretability diagnostic.
| Exp. (ms) | Drop raw amp | Drop raw amp | Drop raw amp | Drop denoised amp | Drop denoised amp | Drop denoised amp | Drop EMCCD likelihood | Drop EMCCD likelihood | Drop EMCCD likelihood | Drop PSF template | Drop PSF template | Drop PSF template |
| 4 | 0.18 | 0.30 | 0.15 | 0.11 | 0.54 | 0.01 | 0.26 | 0.62 | 0.18 | 0.18 | 0.54 | 0.09 |
| 5 | 0.11 | 0.03 | 0.24 | 0.05 | 0.17 | −0.16 | 0.25 | 0.06 | 0.56 | 0.17 | 0.05 | 0.37 |
| 8 | 0.07 | 0.03 | 0.10 | 0.06 | 0.06 | 0.06 | 0.14 | 0.05 | 0.21 | 0.06 | 0.01 | 0.10 |
| 10 | 0.01 | −0.02 | 0.02 | 0.05 | 0.04 | 0.06 | 0.04 | 0.01 | 0.07 | 0.02 | 0.00 | 0.04 |
| 12 | 0.00 | 0.01 | 0.00 | 0.01 | 0.01 | 0.01 | 0.03 | 0.06 | 0.02 | 0.02 | 0.01 | 0.02 |
| 14 | 0.00 | 0.00 | 0.00 | 0.02 | 0.06 | 0.00 | 0.01 | 0.00 | 0.01 | 0.00 | 0.00 | 0.00 |
| 16 | 0.00 | 0.00 | −0.01 | 0.00 | 0.03 | −0.02 | 0.01 | 0.00 | 0.02 | 0.01 | 0.00 | 0.01 |
| 20 | 0.00 | 0.00 | 0.01 | 0.01 | 0.02 | 0.00 | 0.01 | 0.00 | 0.02 | 0.00 | −0.01 | 0.01 |
Table D1. Leave-one-feature-out ablation of the 4D-LR classifier. Each entry reports the performance degradation after removing one feature from the full 4D-LR model. , , and . All values are reported in percentage points.
Table D1 confirms that no single feature alone explains the full performance gain: removing the EMCCD log-likelihood generally causes the largest degradation for ms. These results support the interpretation that 4D-LR improves readout by combining complementary information from photon number, camera-output likelihood, denoised intensity, and empirical spatial structure. Table D2 shows that the EMCCD log-likelihood provides the largest initial improvement beyond raw-count-only logistic regression, especially in the low-photon regime. The denoised photon count feature provides an additional reduction in false-positive rate, while the PSF template-matching score gives a smaller final improvement.
| Exp. (ms) | Feature set | Fid. (%) | FPR (%) | FNR (%) |
| 4 | Raw amp | 93.99 | 15.71 | 3.63 |
| 4 | + EMCCD LL | 95.47 (+1.48) | 11.62 (-4.08) | 2.78 (-0.85) |
| 4 | + Denoised amp | 96.07 (+0.60) | 9.61 (-2.02) | 2.53 (-0.25) |
| 4 | + PSF template | 96.25 (+0.18) | 9.06 (-0.54) | 2.44 (-0.09) |
| 5 | Raw amp | 97.14 | 1.67 | 4.84 |
| 5 | + EMCCD LL | 98.20 (+1.06) | 1.01 (-0.66) | 3.11 (-1.73) |
| 5 | + Denoised amp | 98.42 (+0.22) | 0.75 (-0.26) | 2.95 (-0.16) |
| 5 | + PSF template | 98.60 (+0.17) | 0.70 (-0.05) | 2.57 (-0.37) |
| 8 | Raw amp | 98.76 | 1.09 | 1.35 |
| 8 | + EMCCD LL | 99.36 (+0.60) | 0.54 (-0.55) | 0.72 (-0.63) |
| 8 | + Denoised amp | 99.54 (+0.18) | 0.32 (-0.21) | 0.57 (-0.15) |
| 8 | + PSF template | 99.60 (+0.06) | 0.31 (-0.01) | 0.47 (-0.10) |
| 10 | Raw amp | 99.44 | 0.52 | 0.59 |
| 10 | + EMCCD LL | 99.72 (+0.28) | 0.25 (-0.27) | 0.30 (-0.29) |
| 10 | + Denoised amp | 99.81 (+0.09) | 0.12 (-0.12) | 0.24 (-0.06) |
| 10 | + PSF template | 99.83 (+0.02) | 0.12 (0.00) | 0.21 (-0.04) |
| 12 | Raw amp | 99.74 | 0.43 | 0.20 |
| 12 | + EMCCD LL | 99.90 (+0.16) | 0.13 (-0.30) | 0.10 (-0.10) |
| 12 | + Denoised amp | 99.90 (0.00) | 0.15 (+0.03) | 0.08 (-0.02) |
| 12 | + PSF template | 99.92 (+0.02) | 0.14 (-0.01) | 0.06 (-0.02) |
| 14 | Raw amp | 99.88 | 0.21 | 0.09 |
| 14 | + EMCCD LL | 99.94 (+0.06) | 0.07 (-0.14) | 0.06 (-0.03) |
| 14 | + Denoised amp | 99.97 (+0.03) | 0.01 (-0.06) | 0.04 (-0.02) |
| 14 | + PSF template | 99.97 (0.00) | 0.01 (0.00) | 0.03 (0.00) |
| 16 | Raw amp | 99.91 | 0.04 | 0.11 |
| 16 | + EMCCD LL | 99.94 (+0.03) | 0.05 (+0.01) | 0.06 (-0.05) |
| 16 | + Denoised amp | 99.96 (+0.02) | 0.02 (-0.03) | 0.05 (-0.01) |
| 16 | + PSF template | 99.97 (+0.01) | 0.02 (0.00) | 0.04 (-0.01) |
| 20 | Raw amp | 99.95 | 0.05 | 0.05 |
| 20 | + EMCCD LL | 99.98 (+0.03) | 0.04 (-0.01) | 0.01 (-0.04) |
| 20 | + Denoised amp | 99.98 (0.00) | 0.03 (-0.01) | 0.01 (0.00) |
| 20 | + PSF template | 99.98 (0.00) | 0.04 (+0.01) | 0.01 (-0.01) |
Table D2. Feature-buildup ablation of the 4D-LR classifier. The classifier is built by starting from the raw photon count feature and sequentially adding the background-fitted camera-noise log-likelihood, the denoised photon count, and the PSF template-matching score. Values are reported in percentage. Numbers in parentheses indicate the change relative to the previous buildup step, in percentage points. For fidelity, positive changes indicate improvement; for FPR and FNR, negative changes indicate error reduction. The final step corresponds to the full 4D-LR classifier.
Additional candidate features
We also tested the three additional candidate descriptor groups mentioned in § 1.2. Here we define their implemented forms and evaluate each group by adding it separately to the selected four-feature classifier. This tests its marginal contribution, rather than its predictive power in isolation. Let denote a background-subtracted ROI in ADU, suppressing the site and shot indices. Let be its central pixels and the outer 16 pixels of the ROI.
a. Center concentration. The fraction of positive background-subtracted signal in the central pixels is
Clipping the negative values avoids cancellation in low-signal ROIs. This scalar describes spatial concentration.
b. Learned noise score. The second candidate uses the latent representation of the trained Noise2NoiseFlow noise model. Raw images and the mean background are normalized as and with the offsets and scale in ADU.
The normalized images are replicated into the two input channels used by the saved noise model. Passing through its forward flow gives latent values . The ROI score is
A higher score indicates greater compatibility with the learned background noise.
c. PSF residual structure. Using the same nonnegative, unit-sum empirical template as the PSF correlation feature, we approximate the background-subtracted ROI by , keeping the template shape fixed and fitting only its amplitude. We choose the unconstrained amplitude by unweighted least squares,
Setting the derivative with respect to to zero gives , yielding the fitted amplitude and residual,
The residual group consists of three scalars,
These quantities describe residual energy in the center and outer pixels and the signed center-to-outer imbalance. Table D3 reports the matched changes relative to 4D-LR. The largest observed fidelity increase is 0.025 percentage points, from adding PSF residual structure at 4 ms. All reported 95% intervals for the fidelity change include zero, and no candidate gives a consistent improvement across measurement times. These results support retaining the four-feature representation for the present linear classifier, without ruling out benefits with other classifiers or datasets.
Denoising architecture
Our denoising model is based on the Noise2NoiseFlow framework of Maleky et al. [26], which jointly trains an image denoiser and a noise model using pairs of noisy images, without requiring any clean images for training. The original framework was designed to accommodate variations in noise characteristics across different camera sensors and ISO settings. In contrast, our dataset consists exclusively of single-channel EMCCD fluorescence images acquired using the same Andor iXon Ultra 897 camera at a fixed EM gain of 300. We therefore simplified the original architecture by removing the camera/ISO conditioning and the signal-dependent camera-noise layers, while keeping the central idea of learning from paired noisy observations.
For each exposure time, two consecutively acquired readout images were used as a noisy image pair. These images contain the same nominal atom configuration but independent camera-noise distributions. The denoiser maps one noisy image to a denoised estimate, while the residual between the denoised estimate and the paired noisy observation is evaluated by a normalizing-flow noise model.
The denoiser itself is a single-channel DnCNN [28] with 25 convolutional layers and one-channel input and output. While the original Noise2NoiseFlow implementation used a 9-layer DnCNN, we tested the denoiser depth and a 25-layer DnCNN gave the best validation performance on our EMCCD fluorescence data.
The residual noise model uses a simplified unconditional flow. The flow architecture is
squeeze | unc | unc | gain | unc | unc | gain | unc | unc | unsqueeze.
The squeeze operation rearranges a one-channel image into four channels, which makes channel splitting possible in the following layers. Each unc block consists of an invertible convolution followed by an unconditional affine-coupling layer. The role of these blocks is to transform a simple gaussian distribution into a more complicated residual-noise distribution through a sequence of invertible changes of variables. Stacking several such blocks allows the flow to represent non-Gaussian and asymmetric EMCCD residual statistics that are not captured by a single Gaussian model. The gain layers adjust the overall scale of the modeled residual distribution.
The training objective follows the Noise2NoiseFlow form,
where and are two consecutive noisy atom images. The noise-model term is the negative log-likelihood of the image residual, defined as the difference between a noisy image and its corresponding denoised image. The denoising term compares the denoised prediction obtained from one noisy image with the other independently acquired noisy image of the same underlying scene. This cross-sample formulation enables the denoiser to be trained without requiring a clean target image. The coefficient controls the relative weight of the denoising term. We used the same loss weight as Ref. [26], . The model was optimized with Adam using , , , and a constant learning rate of . The batch size was 8.
Each exposure time was trained independently. For each exposure time, the raw EMCCD intensity was linearly normalized to using a separately chosen range. Training used grayscale images with one patch per image. Training ran for at least 200 epochs and at most 500 epochs. Full validation was performed every 10 epochs, and after epoch 200 early stopping was triggered if the validation negative log-likelihood did not improve by more than for five consecutive validation checks.
We evaluated whether the learned noise model reproduces the measured EMCCD background statistics. For each noise model, we generated synthetic background images and compared their pixel-value histogram with the histogram of measured background images [Fig.E1]. The discrepancy was quantified using the Kullback–Leibler divergence
where is the empirical background pixel-value distribution, is the distribution generated by a candidate noise model, indexes histogram bins. Lower indicates better agreement with the measured EMCCD background statistics. Figure E1 compares Gaussian, Poisson–Gaussian, analytic EMCCD [25], and learned Noise2NoiseFlow background models. The analytic EMCCD model gives the closest agreement with the measured background distribution among the tested models (), while the learned Noise2NoiseFlow residual model achieves a comparable value (). This indicates that the learned model captures much of the measured EMCCD background statistics.
If denoising introduces a spot resembling atomic fluorescence at an empty site, the site may be misclassified as occupied. Such a spurious feature is an example of image hallucination. Generative adversarial network (GAN)-based image restoration methods can improve perceptual realism by matching the output image distribution, but this objective can trade off against distortion fidelity and can generate structures not supported by the input data [42, 43]. Similar concerns apply to GAN-like or image-translation-based denoising approaches when the objective emphasizes visual plausibility rather than statistical consistency with the measured data.
The employed denoising architecture is more conservative in this respect. The DnCNN module enables to predict a residual image, and the normalizing-flow module models the statistics of that residual. Thus, the residual after denoising is encouraged to remain compatible with the measured camera-noise distribution. If the denoiser were to create or remove an atom-like feature, the corresponding residual would contain signal-like components rather than background-like noise. The flow-based residual likelihood and the background-statistics validation therefore provide a safety check against such artifacts. Compared with adversarial image-generation objectives, the DnCNN+Flow formulation is better aligned with conservative scientific denoising, because it models the noise residual explicitly and can be tested against measured background statistics. Figure E2 shows examples of raw fluorescence images and their denoised counterparts at each exposure time.
Figure E2. Gallery of raw and denoised fluorescence images. Samples of raw and denoised images are shown for all measurement times and ms. Within each row, the first three images are raw EMCCD images, and the last three images are the corresponding denoised outputs.

Figure E1. Comparison of learned and analytic EMCCD background-noise models. A real EMCCD background frame is compared with representative synthetic background frames generated from four noise models: a Gaussian model, a Poisson–Gaussian model, an analytic EMCCD model [25], and the learned residual Noise2NoiseFlow [26] model. The comparison was performed for the ms background data. For each noise model, we generated synthetic background images and compared their pixel-value histogram with the histogram of the measured background images. The same histogram bins were used for all models so that the Kullback–Leibler divergence measures only the difference in the generated pixel-value statistics. The number above each image is , where is the measured background histogram and is the histogram of the generated background images. The real background frame is included as a visual reference and has zero divergence by definition. Lower KL divergence indicates closer agreement with the measured EMCCD background statistics.
Rearrangement Simulation
This appendix describes the Monte Carlo rearrangement simulation used to evaluate the effects of readout errors on defect-free atom array preparation. The simulation focuses on the asymmetry between false positives and false negatives during source assignment. A false positive can select an empty reservoir site as an atom source and directly create a target defect, whereas a false negative mainly reduces the available atom pool. We therefore use a simplified model that isolates readout-induced source-assignment errors, rather than modeling the detailed transport trajectory, collision constraints, or motion-control errors of a specific rearrangement algorithm [44, 45].
Each trial starts from an reservoir array with independent loading probability . For a given readout method and exposure time, imaging survival is first sampled using . The measured false-negative rate is applied to surviving atoms, and the false-positive rate to sites empty before imaging. The rearrangement algorithm then selects source atoms from the measured occupied sites and attempts to fill a square target array.
For single-round rearrangement, the target is fixed at and only one readout-and-move cycle is allowed. For multi-round rearrangement, the target side in round is , where is the number of detected candidates retained after erasure filtering. The trial is counted as successful only if the assembled array is defect-free and has side length at least , within at most 20 rounds. After a failed round, the next round is initialized only with atoms that are actually present in the attempted target region. Any unused atoms remaining in the reservoir are discarded and not reused.
For erasure-aware source selection, low-confidence occupied-site predictions are removed from the candidate source pool before rearrangement. This suppresses false source assignments caused by false positives, but also discards some truly occupied atoms. The sweep over erasure budgets therefore measures the tradeoff between removing unreliable source assignments and preserving a sufficiently large atom pool. The effective simulator inputs are
Here, the denominators include all reference-labeled atom-absent or atom-present ROI outcomes before erasure filtering. Algorithm 1 shows this equivalent two-step thinning using unfiltered error rates and conditional candidate-erasure probabilities. Sources are selected uniformly without replacement from the retained candidates. Each condition uses 10,000 trials and defect tolerance zero. For erasure-aware methods, the lowest budget within one Monte Carlo standard error of the maximum success rate is selected from the same sweep, with a maximum budget of 25%. The success of each simulated trial is evaluated from the known simulated ground-truth occupation after rearrangement. This is a simulation oracle criterion, rather than an experimentally implemented stopping measurement.
In the simulation, true-positive source candidates are sampled from atoms surviving imaging, and false-positive candidates from sites that were empty before imaging. We assume that loss-related false-positive assignments are already included in the empirical FPR. Therefore, atoms lost during imaging are not added as separate false-positive source candidates. No additional readout or refill is performed within a round.
Algorithm 1 Monte Carlo rearrangement simulation
Require: Reservoir size , loading probability , readout error rates and , conditional erasure probabilities and , imaging survival probability , protocol mode, maximum rounds , fixed target side , minimum target side , and defect tolerance .
Here, is the probability that a true-positive candidate is erased, and is the probability that a false-positive candidate is erased. Without erasure-aware source selection, both probabilities are set to zero.
1: , ▷ : true atoms, : available sites 2: for do 3: 4: ▷ surviving atoms after imaging 5: ▷ surviving atoms detected as occupied 6: ▷ initially empty sites falsely detected as occupied 7: ▷ true-positive candidates kept after erasure filtering 8: ▷ false-positive candidates kept after erasure filtering 9: 10: if protocol mode is single-round then 11: 12: if then 13: return failure 14: end if 15: else 16: 17: if then 18: return failure 19: end if 20: end if 21: ▷ population , real candidates , draws 22: if then 23: return success 24: else 25: , ▷ conservative cleanup: reuse only the attempted target region 26: end if 27: end for 28: return failure
References
- [1]D. Bluvstein, S. J. Evered, A. A. Geim, S. H. Li, H. Zhou, T. Manovitz, S. Ebadi, M. Cain, M. Kalinowski, D. Hangleiter, et al., Logical quantum processor based on reconfigurable atom arrays, Nature 626, 58 (2024).
- [2]H. J. Machkentsch, G. Nomura, E. Bataille, X. Lv, K. H. Leung, and M. Endres, A tweezer array with 6,100 highly coherent atomic qubits, Nature 647, 60 (2025).
- [3]C. Cicali, M. Calzavara, E. Cuestas, T. Calcarco, R. Zeier, and F. Motzoi, Fast neutral-atom transport and transfer between optical tweezers, Phys. Rev. Applied 24, 024070 (2025).arxiv.org/abs/2412.15173
- [4]S. Hwang, H. Hwang, K. Kim, A. Byun, K. Kim, S. Jeong, M. P. Soegianto, and J. Ahn, Fast and reliable atom transport by optical tweezers, Optica Quantum 3, 64 (2025).arxiv.org/abs/2410.22627
- [5]M. Saffman, Quantum computing with atomic qubit arrays: confronting the cost of connectivity (2025), arXiv:2505.11218 [quant-ph].arxiv.org/abs/2505.11218
- [6]D. Bluvstein, A. A. Geim, S. H. Li, S. J. Evered, J. P. Bonilla Ataides, G. Baranes, A. Gu, T. Manovitz, M. Xu, M. Kalinowski, et al., A fault-tolerant neutral-atom architecture for universal quantum computation, Nature 649, 39 (2026).DOI
- [7]E. Deist, Y.-H. Lu, J. Ho, M. K. Pasha, J. Zeiher, Z. Yan, and D. M. Stamper-Kurn, Mid-circuit cavity measurement in a neutral atom array, Phys. Rev. Lett. 129, 203602 (2022).DOI
- [8]Y. Li, Y. Bao, M. Peper, C. Li, and J. D. Thompson, Fast, continuous and coherent atom replacement in a neutral atom qubit array (2025), arXiv:2506.15633 [quant-ph].DOI
- [9]N.-C. Chiu, E. C. Trapp, J. Guo, M. H. Abobeih, L. M. Stewart, S. Hollerith, P. L. Stroganov, M. Kalinowski, A. A. Geim, S. J. Evered, et al., Continuous operation of a coherent 3,000-qubit system, Nature 646, 1075 (2025).DOI
- [10]S. Veroni, M. Müller, and G. Giudice, Optimized measurement-free and fault-tolerant quantum error correction for neutral atoms, Phys. Rev. Research 6, 043253 (2024).DOI
- [11]M. Cain, Q. Xu, R. King, L. R. B. Picard, H. Levine, M. Endres, J. Preskill, H.-Y. Huang, and D. Bluvstein, Shor’s algorithm is possible with as few as 10,000 reconfigurable atomic qubits (2026), arXiv:2603.28627 [quant-ph].arxiv.org/abs/2603.28627
- [12]C. Zhao, C. Duckering, A. Gu, N. Maskara, and H. Zhou, Towards ultra-high-rate quantum error correction with reconfigurable atom arrays (2026), arXiv:2604.16209 [quant-ph].arxiv.org/abs/2604.16209
- [13]R. Ismail, I.-C. Chen, C. Zhao, R. Weiss, F. Liu, H. Zhou, S.-T. Wang, A. Sornborger, and M. Kornjača, Transversal architecture for megaquop-scale quantum simulation with neutral atoms, PRX Quantum 7, 020343 (2026).DOI
- [14]C. Gidney and M. Ekerå, How to factor 2048 bit RSA integers in 8 hours using 20 million noisy qubits, Quantum 5, 433 (2021), arXiv:1905.09749 [quant-ph].DOI
- [15]H. Ali, J. Marques, O. Crawford, J. Majaniemi, M. Serra-Peralta, D. Byfield, B. Vardanov, B. M. Terhal, L. Di-Carlo, and E. T. Campbell, Reducing the error rate of a superconducting logical qubit using analog readout information, Phys. Rev. Applied 22, 044031 (2024).
- [16]M. D. Hanisch, B. Hetényi, and J. R. Wootton, Soft information decoding with superconducting qubits, APS Open Science 1, 000019 (2026), arXiv:2411.16228 [quant-ph].DOI
- [17]J. Majaniemi and E. S. Matekole, Reducing quantum error correction overhead using soft information, Quantum Sci. Technol. 11, 025024 (2026), arXiv:2504.03504 [quant-ph].
- [18]I. Ulusoy and C. M. Bishop, Generative versus discriminative methods for object recognition, in Proceedings of the 2005 IEEE Computer Society Conference on Computer Vision and Pattern Recognition, Vol. 2 (2005) pp. 258–265.DOI
- [19]A. Y. Ng and M. I. Jordan, On discriminative vs. generative classifiers: A comparison of logistic regression and naive Bayes, in Advances in Neural Information Processing Systems, Vol. 14 (2001) pp. 841–848.
- [20]R. Raina, Y. Shen, A. Y. Ng, and A. McCallum, Classification with hybrid generative/discriminative models, in Advances in Neural Information Processing Systems, Vol. 16 (2003) pp. 545–552.
- [21]R. O. Duda, P. E. Hart, and D. G. Stork, Pattern Classification, 2nd ed. (Wiley, New York, 2001).
- [22]C. N. Mude, L. Phuttitarn, S. Maurya, K. Sinha, M. Saffman, and S. Tannu, Enabling fast and accurate neutral atom readout through image denoising (2025), arXiv:2510.25982 [quant-ph].arxiv.org/abs/2510.25982
- [23]Y. Song, K. Kim, J. H. Han, S. Oh, and J. Mun, High performance imaging of 171Yb atom in shallow clock-magic tweezer by alternating dual-tone narrowline cooling (2026), arXiv:2603.27498 [physics.atom-ph].arxiv.org/abs/2603.27498
- [24]A. Cooper, J. P. Covey, I. S. Madjarov, S. G. Porsev, M. S. Safronova, and M. Endres, Alkaline-earth atoms in optical tweezers, Phys. Rev. X 8, 041055 (2018).DOI
- [25]M. Martinez-Dorantes, W. Alt, J. Gallego, S. Ghosh, L. Ratschbacher, Y. Völzke, and D. Meschede, Fast non-destructive parallel readout of neutral atom registers in optical potentials, Phys. Rev. Lett. 119, 180503 (2017).
- [26]A. Maleky, S. Kousha, M. S. Brown, and M. A. Brubaker, Noise2NoiseFlow: Realistic camera noise modeling without clean images, in Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition (2022) pp. 17632–17641.arxiv.org/abs/2206.01103
- [27]A. Abdelhamed, M. A. Brubaker, and M. S. Brown, Noise modeling with conditional normalizing flows, in Proceedings of the IEEE/CVF International Conference on Computer Vision (2019) pp. 3165–3173.
- [28]K. Zhang, W. Zuo, Y. Chen, D. Meng, and L. Zhang, Beyond a Gaussian denoiser: Residual learning of deep CNN for image denoising, IEEE Trans. Image Process. 26, 3142 (2017).DOI
- [29]D. J. Rezende and S. Mohamed, Variational inference with normalizing flows, in Proceedings of the 32nd International Conference on Machine Learning, Proceedings of Machine Learning Research, Vol. 37 (PMLR, 2015) pp. 1530–1538.arxiv.org/abs/1505.05770
- [30]D. P. Kingma and P. Dhariwal, Glow: Generative flow with invertible 1 × 1 convolutions, in Advances in Neural Information Processing Systems, Vol. 31 (2018).arxiv.org/abs/1807.03039
- [31]F. Zhao, Q. Huang, and W. Gao, Image matching by normalized cross-correlation, in Proceedings of the 2006 IEEE International Conference on Acoustics, Speech and Signal Processing, Vol. 2 (2006) pp. II–729–II–732.
- [32]A. G. Basden, Analysis of electron multiplying charge coupled device and scientific CMOS readout noise models for Shack–Hartmann wavefront sensor accuracy, J. Astron. Telesc. Instrum. Syst. 1, 039002 (2015).DOI
- [33]K. B. W. Harpsøe, M. I. Andersen, and P. Kjæ rgaard, Bayesian photon counting with electron-multiplying charge coupled devices (EMCCDs), Astron. Astrophys. 537, A50 (2012).DOI
- [34]Y. Wu, S. Kolkowitz, S. Puri, and J. D. Thompson, Erasure conversion for fault-tolerant quantum computing in alkaline earth Rydberg atom arrays, Nat. Commun. 13, 4657 (2022).DOI
- [35]M. N. H. Chow, V. Buchemmavari, S. Omanakuttan, B. J. Little, S. Pandey, I. H. Deutsch, and Y.-Y. Jau, Circuit-based leakage-to-erasure conversion in a neutral-atom quantum processor, PRX Quantum 5, 040343 (2024).
- [36]X. Su, M. Liang, T. Zhang, Z. Zhao, P. Yin, Y. Yang, W. Dai, X. Luo, X. Li, and L. You, Field-programmable gate array-accelerated exposure-aware convolutional neural network for fluorescence-based qubit readout, Phys. Rev. Applied 25, 054004 (2026).
- [37]H. Kim, Y. Choi, J. Park, B. Bae, H. Jeong, S. M. Lee, J. Yeon, M. Kim, C. Park, B. Gu, et al., TCP: A tensor contraction processor for AI workloads industrial product, in Proceedings of the 2024 ACM/IEEE 51st Annual International Symposium on Computer Architecture (ISCA) (IEEE, 2024) pp. 890–902.DOI
- [38]B. Jacob, S. Kligys, B. Chen, M. Zhu, M. Tang, A. Howard, H. Adam, and D. Kalenichenko, Quantization and training of neural networks for efficient integer-arithmetic-only inference, in Proceedings of the IEEE Conference on Computer Vision and Pattern Recognition (CVPR) (2018) pp. 2704–2713.arxiv.org/abs/1712.05877
- [39]S. Han, H. Mao, and W. J. Dally, Deep compression: Compressing deep neural networks with pruning, trained quantization and Huffman coding, in International Conference on Learning Representations (ICLR) (2016) arXiv:1510.00149.arxiv.org/abs/1510.00149
- [40]S. K. Esser, J. L. McKinstry, D. Bablani, R. Appuswamy, and D. S. Modha, Learned step size quantization, in International Conference on Learning Representations (ICLR) (2020).
- [41]T. M. Graham, L. Phuttitarn, R. Chinnarasu, Y. Song, C. Poole, K. Jooya, J. Scott, A. Scott, P. Eichler, and M. Saffman, Midcircuit measurements on a single-species neutral alkali atom quantum processor, Phys. Rev. X 13, 041051 (2023).DOI
- [42]Y. Blau and T. Michaeli, The perception-distortion tradeoff, in Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) (2018) pp. 6228–6237.DOI
- [43]J. P. Cohen, M. Luck, and S. Honari, Distribution matching losses can hallucinate features in medical image translation, in Medical Image Computing and Computer Assisted Intervention – MICCAI 2018 (Springer, 2018) pp. 529–536.DOI
- [44]H. Kim, M. Kim, W. Lee, and J. Ahn, Gerchberg-Saxton algorithm for fast and efficient atom rearrangement in optical tweezer traps, Opt. Express 27, 2184 (2019).DOI
- [45]R. Lin, H.-S. Zhong, Y. Li, Z.-R. Zhao, L.-T. Zheng, T.-R. Hu, H.-M. Wu, Z. Wu, W.-J. Ma, Y. Gao, et al., All-enabled parallel assembly of thousands of defect-free neutral atom arrays, Phys. Rev. Lett. 135, 060602 (2025).DOI