Magnonic cavity-enhanced quantum magnetometry with nitrogen-vacancy centre ensembles

Abstract

Nitrogen-vacancy (NV) centre ensembles are leading room-temperature magnetometers, but their sensitivity is usually extracted from a single resonance and relies on external microwave and bias-field hardware. This work proposes a chip-scale NV magnetometer built around a one-dimensional YIG/CoFeB magnonic crystal, in which a single structural defect forms a passive magnonic cavity and integrated permanent magnets supply the bias field. Micromagnetic simulations show a defect-localised spin-wave mode at 2.910 GHz inside the 2.5-3.0 GHz magnonic band gap, 40 MHz from the NV zero-field splitting, with a band structure that matches an independent plane-wave calculation. A Tavis-Cummings/Lindblad model in which the microwave reaches the NV ensemble through this mode predicts a hyperfine-resolved optically detected magnetic resonance spectrum that is strong only within the mode linewidth, and a dispersive homodyne response with one steep edge per 14^{14}N hyperfine line. The master-equation solutions agree with the closed-form homodyne steady state (R2>0.9999R^2 > 0.9999) and with an approximate analytic ODMR theory (peak positions within 0.012 MHz). For a critically coupled readout with room-temperature electronics, combining the three edges gives a projected sensitivity of 93 pT/Hz\sqrt{\rm Hz}, a 3\sqrt{3}-fold gain over the best single edge. Mapping the sensitivity against the NV-magnon coupling reveals an optimum near gens/2π≈0.2g_{\rm ens}/2π\approx 0.2-0.40.4 MHz, where it reaches 72 pT/Hz\sqrt{\rm Hz} for a 0.64 MHz spin linewidth and 19 pT/Hz\sqrt{\rm Hz} for 0.17 MHz, with thermal limits of 6.6 and 1.7 pT/Hz\sqrt{\rm Hz}. The antenna-mode coupling, the NV-magnon coupling and the spin linewidth are therefore the main design levers.

Introduction

The ensembles of nitrogen-vacancy (NV) centres in diamond are among the most widely used solid-state platforms for room-temperature magnetometry, owing to their optical addressability and long spin coherence times [1, 2, 3, 4] [5]. Researchers have developed single NV spins and NV ensembles into a quantum sensing toolkit for condensed-matter imaging, biology, and geoscience, [6, 7] and naval magnetic anomaly detection (MAD) has emerged as one of the most demanding applications. [8]

The photon-collection efficiency of the optical readout channel fundamentally limits the ensemble sensitivity. Coupling the ensemble to a microwave cavity addresses this limitation by transducing the spin signal through a broadband microwave channel, [9, 10] building on coherent magnon–photon coupling in cavity magnonics. [11–13] In a strongly driven, weakly coupled regime, H. Kumar et al. [14] recently showed that such a cavity creates doubly dressed NV states: Autler–Townes-split [15] hyperfine transitions are further split by vacuum-Rabi coupling to the cavity, producing nine spectrally resolved peaks. Together, these peaks provide nearly a threefold sensitivity enhancement over single-peak readout, with a measured sensitivity of 12 pT/Hz\sqrt{\mathrm{Hz}} and a projected path of 100 fT/Hz\sqrt{\mathrm{Hz}}.

NV spins also couple directly to magnons in an adjacent ferromagnetic film through the dipolar interaction, so that a magnon mode can act as a coherent near-resonant drive instead of a microwave antenna [16–18]. Magnonic crystals, the magnetic counterpart of photonic crystals, are periodically modulated magnetic media in which Bragg scattering opens spin-wave band gaps[19, 20]. Yttrium iron garnet (YIG) supports low-loss magnonic filters, delay lines, and field sensors[21–26]. Most importantly for NV dressing, a local break in periodicity pulls a spatially localised high-quality factor mode into the band gap, in direct analogy with a photonic-crystal defect cavity[27–29]. Earlier studies, including work by the author, have demonstrated such defects and cavity modes in bicomponent stripe and garnet-based structures closely related to the one studied here[30–35].

A magnonic cavity offers a practical advantage over the actively pumped, resonantly matched dielectric resonator of the cavity-driven scheme, which requires continuous drive power, precise tuning, and dedicated microwave hardware. A simple antenna or stripline patterned on the magnetic film can excite the magnonic cavity, so a magnon-mediated multispectral magnetometer could take the form of a compact chip-scale sensing element. This work numerically investigates whether a passive one-dimensional (1D) YIG/CoFeB magnonic cavity can reproduce the multispectral dressing physics of ref. [14]. Micromagnetic simulations with MuMax3[36] identify the defect-localised mode and its dynamic dipolar field at the NV site; a plane-wave method (PWM)[30, 37–39] independently verifies the band structure; and a Tavis–Cummings/Lindblad model solved in QuTiP[40] converts this field into hyperfine-resolved spectra and multispectral sensitivity.

Results

Theoretical framework

A Tavis–Cummings-type Hamiltonian[41] describes an NV ensemble coupled to a single bosonic mode aa[14]. Because the microwave field does not drive transitions between hyperfine sublevels of 14N{}^{14}\mathrm{N}, each nuclear spin state mI∈{−1,0,+1}m_I \in\{-1, 0, +1\} forms an independent two-level system on the ms=0↔ms=+1m_s = 0 \leftrightarrow m_s = +1 transition. A strong classical field splits each transition into two dressed states separated by the Rabi frequency Ω\Omega, giving a Mollow triplet[42] per hyperfine state and nine lines in total; coupling to the bosonic mode then splits these lines further. In a frame rotating at the drive frequency ωd\omega_d (with ℏ=1\hbar= 1),

H=Δca†a+∑j=−1+1[Δj2σjz+gens(aσj++a†σj−)+Ω2(σj++σj−)](1)H = \Delta_c a^\dagger a + \sum_{j=-1}^{+1} \left[ \frac{\Delta_j}{2}\sigma_j^z + g_{\mathrm{ens}}\left(a\sigma_j^+ + a^\dagger\sigma_j^-\right) + \frac{\Omega}{2}\left(\sigma_j^+ + \sigma_j^-\right) \right] \tag*{(1)}

where Δc=ωc−ωd\Delta_c = \omega_c - \omega_d and Δj=ωj−ωd\Delta_j = \omega_j - \omega_d are the re-tunings of the mode and spin, σj±\sigma_j^\pm and σjz\sigma_j^z are the spin operators of sector jj, and gens=gNsg_{\mathrm{ens}} = g\sqrt{N_s} is the collective coupling of the spins NsN_s. In the present work, aa is the defect-localised magnon mode rather than a cavity photon. The transverse dipolar field of this mode at the NV site sets the Rabi frequency Ω\Omega, and the field per magnon sets gensg_{\mathrm{ens}}. Both architectures therefore share the same Hamiltonian; they differ in the mode linewidth, in the coupling of the mode to the external microwave line and in the coupling strengths, which together set the sensitivity. The Lindblad master equation[43] accounts for dissipation,

ρ˙=−i[H,ρ]−γ02D[a]ρ−∑j,kγk2D[σjk]ρ(2)\dot{\rho} = -i[H,\rho] - \frac{\gamma_0}{2}\mathcal{D}[a]\rho- \sum_{j,k}\frac{\gamma_k}{2}\mathcal{D}[\sigma_j^k]\rho \tag*{(2)}

with D[x]ρ={x†x,ρ}−2xρx†\mathcal{D}[x]\rho= \{x^\dagger x,\rho\} - 2x\rho x^\dagger, σjk∈{σj−,σjz}\sigma_j^k \in\{\sigma_j^-,\sigma_j^z\}, mode loss rate γ0\gamma_0, spin relaxation rate γ∥\gamma_{\parallel} and dephasing rate γ⊥\gamma_{\perp}.

Magnonic band gap and the defect-localised mode

Fig. Figure 1 shows the proposed device and its measurement setup. The chip carries a 1D magnonic crystal of YIG segments separated by CoFeB stripes on a gadolinium gallium garnet (GGG) substrate. A longer central YIG segment forms a defect cavity at x=16,250x = 16{,}250 nm, and NV-containing nanodiamonds sit on this cavity. Thin-film permanent magnets patterned at both ends of the crystal supply the in-plane bias field H0∥xH_0 \parallel x, so no external electromagnet is needed, and two microstrip antennas across the first and last YIG segments launch and detect spin waves for transmission spectroscopy. The simulations represent the magnet stray field by a uniform bias Bext=101.4B_{\mathrm{ext}} = 101.4 mT along xx, under which the MuMax3 relax() routine brings the crystal to equilibrium (static stray field maps in Supplementary Figs. S1 and S2). Two independent calculations then establish the band structure of the pristine crystal (Fig. Figure 2a). The micromagnetic dispersion and the PWM bands agree without adjustable parameters: the PWM reproduces the dispersive doublets near 0.85–0.95 and 2.7–3.0 GHz and the zone-folded band near 1.5 GHz with its Bragg-like kinks, while a few weak features absent from the linear PWM point to higher-order spin-wave processes (Supplementary Note 2).

Figure 1. Schematic of the proposed on-chip magnonic-crystal/NV-centre device and its measurement setup. Top: the integrated chip is mounted on a sample stage. A microwave signal generator feeds the input microstrip antenna through an SMA connector (input signal). Spin waves launched by the antenna propagate along xx through the magnonic crystal; the output microstrip antenna detects them inductively (output signal), and the spectrum analyser amplifies and records the transmission spectrum. No external electromagnet is required. Bottom (enlarged): the device is a one-dimensional magnonic crystal formed by YIG segments of length ss separated by CoFeB stripes of width dd (lattice constant a=s+da = s + d) on a GGG substrate. A longer central YIG segment acts as a defect cavity that confines a spin-wave mode within the magnonic band gap, and nanodiamonds containing NV centres are deposited on this cavity. Thin-film permanent magnets (for example SmCo, NdFeB or CoPt), patterned on the same substrate at both ends of the crystal and magnetised along H0H_0, present N and S poles to the crystal; their stray field (dashed lines) supplies the in-plane bias field H0∥xH_0 \parallel x, parallel to the direction of periodicity. The input and output microstrip antennas span the first and last YIG segments, run parallel to yy, and are fed from pads at the substrate edge. Drawing not to scale.

Band structure and the defect-localised mode

Figure 2. Band structure and the defect-localised mode. (a) Micromagnetically simulated dispersion of the pristine 1D YIG/CoFeB crystal (colour map, log⁡10\log_{10} intensity of the space–time Fourier transform of the ring-down response versus normalised Bloch wave vector), overlaid without adjustable parameters on the independently computed plane-wave bands (cyan curves). (b) Total spin-wave spectral power S(f)S(f) of the crystal with the defect, showing the magnonic band gap (shaded, 2.5–3.0 GHz) and the single defect-localised mode at 2.910 GHz (red dashed line) just above the NV zero-field splitting at 2.87 GHz (cyan dash-dotted line).

A spatially uniform broadband sinc-pulse field (10 mT amplitude, 5 GHz cut-off) then excites the relaxed crystal, and the simulation records the volume-averaged magnetisation (Fig. Figure 3). The static component ⟨mx⟩\langle m_x\rangle settles within about 25 ns, while the transverse components ⟨my⟩\langle m_y\rangle and ⟨mz⟩\langle m_z\rangle decay over roughly 150 ns as the excited spin-wave modes dephase and damp. The Fourier transform of ⟨mz(t)⟩\langle m_z(t)\rangle gives the spin-wave spectral power S(f)S(f) (Figure 2b), which shows an allowed-band continuum and a band gap between 2.5 and 3.0 GHz. Inside this gap, a single narrow resonance appears at flocal=2.910f_{\mathrm{local}} = 2.910 GHz, close to the NV zero-field splitting fZFS=2.87f_{\mathrm{ZFS}} = 2.87 GHz. The defect-supercell dispersion (Supplementary Fig. S3) confirms that this state lies in a gap of the pristine crystal rather than on a folded bulk band, and the per-cell mode profile (Figure 4a) confirms its confinement at the defect.

Magnetisation dynamics after broadband excitation

Figure 3. Magnetisation dynamics after broadband excitation. Volume-averaged magnetization components ⟨mx⟩\langle m_x\rangle, ⟨my⟩\langle m_y\rangle and ⟨mz⟩\langle m_z\rangle versus time after the broadband sinc pulse applied uniformly across the device. Bottom right: Fourier spectrum of ⟨mz(t)⟩\langle m_z(t)\rangle, showing the defect-localised resonance at 2.910 GHz (red dashed line) close to the NV zero-field splitting at 2.87 GHz (cyan dash-dotted line).

Localised mode and its dynamic field at the NV site

Figure 4. Localised mode and its dynamic field at the NV site. (a) Left: static ∣Bstray∣|B_{\mathrm{stray}}| along the device, with edge-exclusion zones shaded. Middle: normalised localised-mode mzm_z amplitude (blue) and dynamic stray-field envelope (red), showing the ≈90∘\approx90^\circ spatial offset between the mode maximum at the defect centre and the field maxima on its flanks. Right: dynamic stray field at 2.910 GHz with its two flanking peaks. The red dashed line marks the NV position used here (x=13,755x = 13{,}755 nm). (b) Left: dynamic stray field Bz(t)B_z(t) at the NV position, oscillating about the static background offset (−1,267,664-1{,}267{,}664 nT, red dashed line). Right: Fourier spectrum ∣FFT(Bz)∣|\mathrm{FFT}(B_z)|, giving Blocal=26.60B_{\mathrm{local}} = 26.60 nT at flocal=2.910f_{\mathrm{local}} = 2.910 GHz (red dashed line), close to the NV zero-field splitting of 2.87 GHz (cyan dash-dotted line).

Dynamic dipolar field at the NV site

For NV detection, the relevant quantity is the dynamic dipolar field. The localised mode is produced at the NV positions, which the analysis takes directly from the MuMax3 BdemagB_{\mathrm{demag}} output at each time step and Fourier transforms at each candidate position. Because the spatial gradient of the mode profile, rather than the mode amplitude, generates this field, ∣Bdyn(x)∣\lvert B_{\mathrm{dyn}}(x)\rvert peaks on the flanks of the defect, at x≈16,175x \approx16,175 and 16,320 nm, rather than at its centre (Figure 4a). The present analysis places the NV ensemble at x=13,755x = 13,755 nm, the position of the maximum static stray field within the search window (Supplementary Fig. S2). At this position, Bz(t)B_z(t) oscillates about a large static offset of −1,267,664-1,267,664 nT arising from the demagnetising field of the DC-biased crystal (Figure 4b, left). After subtracting this offset, the Fourier spectrum gives Blocal=26.60B_{\mathrm{local}} = 26.60 nT at flocal=2.910f_{\mathrm{local}} = 2.910 GHz (Figure 4b, right). This value is the spectral amplitude of the response to the broadband pulse. Under continuous-wave (CW) excitation of the antenna at flocalf_{\mathrm{local}}, the micromagnetic response is linear, and the ratio between the local dynamic field and the applied antenna field defines a magnonic field enhancement factor E=Blocal/Bsignal=0.3125\mathcal{E} = B_{\mathrm{local}}/B_{\mathrm{signal}} = 0.3125 (Blocal=156 μTB_{\mathrm{local}} = 156\,\mu\mathrm{T} for Bsignal=0.5 mTB_{\mathrm{signal}} = 0.5\,\mathrm{mT}). Because the dynamic field peaks on the defect flanks, positions closer to them would give a substantially larger local field, a point revisited in the Discussion.

Magnon-dressed NV spectra

In the device, the antenna does not drive the NV centres directly; it excites the defect mode, whose transverse dipolar field drives the ms=0↔ms=+1m_s = 0 \leftrightarrow m_s = +1 transition of each hyperfine sector. The drive therefore reaches the spins through the mode line. For a drive detuned by Δd=ωd−ωc\Delta_d = \omega_d - \omega_c from the mode, the Rabi frequency follows the Lorentzian amplitude response of the mode,

Ω(Δd)=Ω01+(2Δd/κm)2,Ω02π=γeB⊥,local,(3)\Omega(\Delta_d) = \frac{\Omega_0}{\sqrt{1 + (2\Delta_d/\kappa_m)^2}}, \qquad\frac{\Omega_0}{2\pi} = \gamma_e B_{\perp,\mathrm{local}}, \tag*{(3)}

where κm\kappa_m is the full linewidth of the defect mode, γe=28\gamma_e = 28 GHz/T and B⊥,localB_{\perp,\mathrm{local}} is the component of the local dynamic field transverse to the NV axis when the drive is on the mode resonance. With E=0.3125\mathcal{E} = 0.3125, the value Ω0/2π=0.10\Omega_0/2\pi= 0.10 MHz used below corresponds to B⊥,local≈3.6B_{\perp,\mathrm{local}} \approx3.6 μ\muT, that is, to an antenna field of about 11 μ\muT; this keeps the spins in the moderately driven regime in which the three hyperfine lines stay resolved. The axes of the spectra are referred to the mode frequency, Δs=ωs−ωc\Delta_s = \omega_s-\omega_c and Δd=ωd−ωc\Delta_d = \omega_d-\omega_c, as in ref. [14]; in the rotating frame of Eq. (1), Δc=−Δd\Delta_c = -\Delta_d and Δj=Δs+mIAhf−Δd\Delta_j = \Delta_s + m_I A_{\mathrm{hf}}-\Delta_d.

Figure 5 shows the resulting ODMR spectrum, obtained from the steady state of Eqs. (1)–(2) with the defect mode included (κm/2π=1.0\kappa_m/2\pi= 1.0 MHz, gens/2π=0.25g_{\mathrm{ens}}/2\pi= 0.25 MHz), an ensemble dephasing time T2∗=0.5T_2^* = 0.5 μ\mus, optical repolarisation into ms=0m_s = 0 at Γp=0.1\Gamma_p = 0.1 μs−1\mu\mathrm{s}^{-1}, T1=1T_1 = 1 ms and equal weights for the three 14N{}^{14}\mathrm{N} projections, which are equally populated at room temperature. The ODMR signal is the steady-state population transferred out of ms=0m_s = 0, averaged over the three sectors and normalised once over the whole map. Three features stand out. First, the signal lies on three parallel ridges of unit slope, Δd=Δs+mIAhf\Delta_d = \Delta_s + m_I A_{\mathrm{hf}} with Ahf=2.16A_{\mathrm{hf}} = 2.16 MHz (dashed lines), because the drive flips a spin only when its frequency matches that of the spin. Second, the ridges are strong only where they cross the defect-mode line (∣Δd∣≲κm/2|\Delta_d| \lesssim\kappa_m/2, green band) and fade rapidly away from it, because the mode transmits the drive efficiently only near its own frequency (Eq. (3)). Third, a weak horizontal band appears at Δd≈0\Delta_d \approx0 for all Δs\Delta_s: there the drive is strongest, and even spins far from resonance are weakly excited off-resonantly. This band is not an additional resonance.

Simulated ODMR spectrum of the NV ensemble driven through the defect magnon mode

Figure 5. Simulated ODMR spectrum of the NV ensemble driven through the defect magnon mode. (a) Normalised ODMR signal versus spin detuning Δs/2π\Delta_s/2\pi and drive detuning Δd/2π\Delta_d/2\pi, both referred to the defect-mode frequency fmode=2.910f_{\mathrm{mode}} = 2.910 GHz, from the steady state of the Lindblad master equation Eqs. (1)–(2) with the defect mode included and the drive filtered by the mode line Eq. (3). Dashed lines: hyperfine resonance conditions Δd=Δs+mIAhf\Delta_d = \Delta_s + m_I A_{\mathrm{hf}} (mI=+1,0,−1m_I = +1, 0, -1 in orange, red and blue). Green dashed lines: defect-mode line, ∣Δd∣<κm/2|\Delta_d| < \kappa_m/2. Vertical dashed lines: positions of the cuts in (b). (b) Cuts at Δs/2π=0\Delta_s/2\pi= 0 and ±5\pm5 MHz; shaded band, defect-mode line. Parameters: Ω0/2π=0.10\Omega_0/2\pi= 0.10 MHz (on the mode resonance), κm/2π=1.0\kappa_m/2\pi= 1.0 MHz, gens/2π=0.25g_{\mathrm{ens}}/2\pi= 0.25 MHz, Ahf=2.16A_{\mathrm{hf}} = 2.16 MHz, T2∗=0.5T_2^* = 0.5 μ\mus, Γp=0.1\Gamma_p = 0.1 μs−1\mu\mathrm{s}^{-1}, T1=1T_1 = 1 ms and equal mIm_I weights. We apply a single normalisation to the whole map.

The line cuts in Figure 5b make this quantitative. At Δs=0\Delta_s = 0, the central line, which lies inside the mode line, reaches unit height, while the two outer hyperfine lines at Δd/2π=±2.15\Delta_d/2\pi= \pm2.15 MHz reach only 0.30, although all three sectors carry equal weight: they lie outside the 1 MHz-wide mode line and therefore receive a weaker drive. At Δs/2π=±5\Delta_s/2\pi= \pm5 MHz, the three hyperfine lines appear at ±2.83\pm2.83, ±5.00\pm5.00 and ±7.15\pm7.15 MHz with heights 0.22, 0.10 and 0.06, decreasing with distance from the mode, together with the off-resonant feature of height 0.16 near Δd=0\Delta_d = 0. A passive magnonic cavity therefore drives strongly only the hyperfine line that lies within its linewidth; a mode linewidth comparable to 2Ahf2A_{\mathrm{hf}} would drive all three lines nearly equally. Only three distinct lines exist at any single bias field; the nine peaks of Figure 5b are these three lines viewed at three bias fields. Resolving the Autler–Townes (Mollow) sidebands of ref. [14] as additional ODMR features would require Ω\Omega to exceed the spin linewidth, a regime we do not pursue here.

For the microwave (homodyne) readout, a weak probe is reflected at the antenna frequency ωp\omega_p, and the defect mode plays the role of the cavity mode aa from ref. [14]. The ensemble coupling to the mode follows from the dynamic field per magnon,

gens=γeBlocalneff,(4)g_{\mathrm{ens}} = \frac{\gamma_e B_{\mathrm{local}}}{\sqrt{n_{\mathrm{eff}}}}, \tag*{(4)}

where neffn_{\mathrm{eff}} is the number of magnons in the defect mode that produces the local field BlocalB_{\mathrm{local}}. A reliable value of neffn_{\mathrm{eff}} requires the mode energy of the micromagnetic simulation; here gens/2π=0.25g_{\mathrm{ens}}/2\pi= 0.25 MHz is used as a representative value, the same as in Figure 5, and its influence on the sensitivity is mapped in Figure 8. Eliminating the spin coherences from the quantum Langevin equations[44] (Supplementary Note 3) gives the steady-state mode amplitude

Figure 8. Design levers of the projected sensitivity. Three-edge sensitivity ηmulti\eta_{\mathrm{multi}} for a −40-40 dBm probe at room temperature and spin linewidths Γ/2π=0.64\Gamma/2\pi= 0.64 MHz (blue) and 0.17 MHz (orange). Solid lines: projected sensitivity, including the technical-noise excess of ref. [14]; dashed lines: thermal (Johnson–Nyquist) limit. (a) Versus NV–magnon coupling gens/2πg_{\mathrm{ens}}/2\pi for an antenna critically coupled to the defect mode (κm/2π=1.0\kappa_m/2\pi= 1.0 MHz). (b) Versus antenna–mode coupling κext/κint\kappa_{\mathrm{ext}}/\kappa_{\mathrm{int}} for κint/2π=0.5\kappa_{\mathrm{int}}/2\pi= 0.5 MHz and gens/2π=0.25g_{\mathrm{ens}}/2\pi= 0.25 MHz; black dashed line, critical coupling; circles, computed optima; dotted lines, κext=κint+4gens2/Γ\kappa_{\mathrm{ext}} = \kappa_{\mathrm{int}} + 4g_{\mathrm{ens}}^2/\Gamma. The green stars mark the parameters of Figure 5–Figure 6 (93 pT/Hz\sqrt{\mathrm{Hz}}).

α=iϵiΔc+γ0/2−gens2P∑j(iΔj+Γ/2)−1,Δj=Δs+mIAhf+Δc,(5)\alpha= \frac{i\epsilon}{i\Delta_c + \gamma_0/2 - g_{\mathrm{ens}}^2 P \sum_j (i\Delta_j + \Gamma/2)^{-1}}, \qquad\Delta_j = \Delta_s + m_I A_{\mathrm{hf}} + \Delta_c, \tag*{(5)}

where Δc=ωc−ωp\Delta_c = \omega_c - \omega_p is the detuning of the probe mode, which is swept, ϵ=κextamw\epsilon= \sqrt{\kappa_{\mathrm{ext}}}a^{\mathrm{mw}} is the probe amplitude coupled into the mode through the antenna (κext\kappa_{\mathrm{ext}} is the antenna–mode coupling rate), γ0=κm\gamma_0 = \kappa_m is the total mode loss rate, P≃−1P \simeq-1 is the spin polarisation maintained by optical pumping, and Γ=2/T2∗\Gamma= 2/T_2^* is the full spin linewidth (Γ/2π=0.64\Gamma/2\pi= 0.64 MHz for T2∗=0.5 μsT_2^* = 0.5\,\mu\mathrm{s}). The factor ii fixes the quadrature phase so that Re⁡α>0\operatorname{Re}\alpha> 0 is above the mode resonance. Because Δj\Delta_j contains Δc\Delta_c, each spin maintains a fixed frequency while the probe is swept. Figure 6a,Figure 6b show Re⁡⟨a⟩\operatorname{Re}\langle a\rangle on the (Δs,Δc)(\Delta_s,\Delta_c) grid from the closed form of Eq. (5) (Theory) and from the steady-state density matrix of the full master equation with mode, three spin sectors and a weak probe ϵ/2π=0.01\epsilon/2\pi= 0.01 MHz (Simulation), using the same parameters as Figure 5. Both maps show the dispersive response of the defect mode, positive above and negative below Δc=0\Delta_c = 0 over a range set by γ0\gamma_0, crossed by three tilted features where the hyperfine lines pull the mode frequency. The cut at Δc=0\Delta_c = 0 (Figure 6c) is a sawtooth with one steep edge per hyperfine line, at Δs/2π=−2.18\Delta_s/2\pi= -2.18, 0 and +2.18+2.18 MHz, with nearly equal maximum slopes ∣dRe⁡⟨a⟩/dΔs∣≈0.012\lvert d\operatorname{Re}\langle a\rangle/d\Delta_s\rvert\approx0.012 per MHz (green dotted lines). These edges are the magnetometer’s operating points: a field change shifts ωs\omega_s, moves the sensor along an edge, and changes the reflected quadrature in proportion to the slope.

Figure 6. Homodyne response and projected sensitivity of the defect-mode readout. (a) Steady-state reflected quadrature Re⁡⟨a⟩\operatorname{Re}\langle a\rangle versus spin detuning Δs/2π\Delta_s/2\pi and mode–probe detuning Δc/2π\Delta_c/2\pi from the closed-form expression, Eq. (5) (Theory). (b) The same quantity from the full Lindblad master equation (Simulation). (c) Cut at Δc=0\Delta_c = 0: theory (line) and simulation (markers); green dotted lines mark the steepest slopes used for the sensitivity. (d) Computed magnetic-noise spectral density η(f)\eta(f) of the three edges combined, for an antenna critically coupled to the defect mode, a −40-40 dBm probe and room temperature, obtained from the frequency-dependent response of the reflected quadrature to an oscillating field (Methods). Dashed line: thermal (Johnson–Nyquist) limit; solid line: projected sensitivity including the technical-noise excess of the readout chain of ref. [14]. The sensitivity is flat at 9393 pT/Hz\sqrt{\mathrm{Hz}} (8.58.5 pT/Hz\sqrt{\mathrm{Hz}} thermal) up to about 100100 kHz and rolls off above the 360360 kHz bandwidth set by the spin and mode linewidths. Parameters: γ0/2π=κm/2π=1.0\gamma_0/2\pi= \kappa_m/2\pi= 1.0 MHz, gens/2π=0.25g_{\mathrm{ens}}/2\pi= 0.25 MHz, Γ/2π=0.64\Gamma/2\pi= 0.64 MHz, ϵ/2π=0.01\epsilon/2\pi= 0.01 MHz, Ahf=2.16A_{\mathrm{hf}} = 2.16 MHz.

Multispectral sensitivity

The sensitivity for a single spectral feature follows the slope-detection framework of lock-in spin-resonance magnetometry [14, 45, 46]. The homodyne quadrature VQ(ωs)V_Q(\omega_s) varies with the spin frequency ωs\omega_s, which an external field δB\delta B shifts through γe\gamma_e. At the steepest point of the jjth edge, δVQ(j)=SjγeδB\delta V_Q^{(j)} = S_j\gamma_e\delta B with

Sj=∣dVQdωs∣max⁡(j),(6)S_j = \left|\frac{dV_Q}{d\omega_s}\right|_{\max}^{(j)}, \tag*{(6)}

and with r.m.s. quadrature noise σj\sigma_j and integration time τ\tau, the single-feature sensitivity is

ηj=3σjτγeSj.(7)\eta_j = \frac{\sqrt{3}\sigma_j\sqrt{\tau}}{\gamma_e S_j}. \tag*{(7)}

The prefactor 3\sqrt{3} is retained from ref. [14] for direct comparison; it describes the projection cos⁡54.7∘=1/3\cos54.7^\circ= 1/\sqrt{3} of a bias field along ⟨100⟩\langle100\rangle onto each NV axis, and for randomly oriented nanodiamonds the orientation average changes it by a factor of order unity. Features that are resolved at the same operating point give independent estimates of δB\delta B and combine in quadrature,

ηmulti=(∑j=1Mηj−2)−1/2,(8)\eta_{\mathrm{multi}} = \left(\sum_{j=1}^{M}\eta_j^{-2}\right)^{-1/2}, \tag*{(8)}

where MM counts the edges present in one bias field. For the device in defect-mode, M=3M = 3 (Figure 6c).

Without a fabricated device, we cannot measure σj\sigma_j, so we project the sensitivity in two steps (Methods). First, the slope of the reflected quadrature, calculated from Eq. (5) for a critically coupled antenna (κext=κm/2\kappa_{\mathrm{ext}} = \kappa_m/2) and a probe of −40-40 dBm, is divided by the thermal noise (Johnson–Nyquist) of a room-temperature readout [47]. This gives a thermal limit of 14.714.7 pT/Hz\sqrt{\mathrm{Hz}} for each edge and 8.58.5 pT/Hz\sqrt{\mathrm{Hz}} for the three combined. Second, the same calculation for the parameters of ref. [14] gives 1.11.1 pT/Hz\sqrt{\mathrm{Hz}}, against the measured 1212 pT/Hz\sqrt{\mathrm{Hz}}; a practical homodyne chain adds a technical-noise excess of about 11. Applying the same excess gives projected sensitivities of 161 pT/Hz\sqrt{\mathrm{Hz}} for the best single edge and ηmulti=93\eta_{\mathrm{multi}} = 93 pT/Hz\sqrt{\mathrm{Hz}} for the three edges, a multiplexing gain of 1.72, close to the 3\sqrt{3} expected for three edges of nearly equal slope. Figure 6d shows how this sensitivity depends on the frequency of the measured field. A field oscillating at frequency ff modulates the spin frequencies, and the coupled mode–spin system follows the modulation only up to a rate set by its linewidths. The computed η(f)\eta(f) is therefore flat at the projected floor from the lowest frequencies up to about 100 kHz, which covers the band relevant to magnetic-anomaly detection and geomagnetic navigation, and rises above a −3-3 dB bandwidth of about 360 kHz. The small features near 2 MHz appear where the modulation sidebands reach the neighbouring hyperfine lines. A real readout would add 1/f1/f noise and pickup at low frequencies, which the model does not include. The antenna coupling κext\kappa_{\mathrm{ext}} enters directly and is analysed in Figure 8b: the best readout is obtained when the antenna is matched to the total internal loss of the mode at the operating point, which includes the absorption by the spins, and the sensitivity degrades rapidly for weak antenna coupling[48]. The coupling of the antenna to the nanoscale defect mode is, therefore, a key quantity for an experimental device.

Theory–simulation validation

Because the sensitivity rests on slopes extracted from the numerical master-equation solution, we checked each route against an independent analytic treatment.

ODMR route

Figure 7 shows the ODMR spectrum from an approximate analytic steady state (Supplementary Note 3). Each hyperfine sector is treated as a driven two-level system with the drive of Eq. (3); the defect mode is eliminated adiabatically, which adds a Purcell decay ΓP=gens2γ0/(Δsj2+γ02/4)\Gamma_{\mathrm{P}} = g_{\mathrm{ens}}^{2}\gamma_{0}/(\Delta_{\mathrm{sj}}^{2}+\gamma_{0}^{2}/4) and a mode-induced frequency pull δL=gens2Δsj/(Δsj2+γ02/4)\delta_{\mathrm{L}} = g_{\mathrm{ens}}^{2}\Delta_{\mathrm{sj}}/(\Delta_{\mathrm{sj}}^{2}+\gamma_{0}^{2}/4) to each sector, with Δsj=Δs+mIAhf\Delta_{\mathrm{sj}} = \Delta_{\mathrm{s}} + m_{I}A_{\mathrm{hf}} the spin–mode detuning. The analytical map reproduces the three ridges, their confinement to the mode line and the off-resonant band at Δd≈0\Delta_{\mathrm{d}} \approx0 (Figure 7a). In the cuts (Figure 7b), the peak positions agree with the simulation of Figure 5b to within 0.012 MHz r.m.s., and the analytic ridges follow the lines Δd=Δs+mIAhf\Delta_{\mathrm{d}} = \Delta_{\mathrm{s}} + m_{I}A_{\mathrm{hf}} (orange). The analytic heights of the outer lines are larger than the simulated ones (0.41 instead of 0.30 at Δs=0\Delta_{\mathrm{s}} = 0, and 0.31 instead of 0.22 at Δs/2π=±5\Delta_{\mathrm{s}}/2\pi= \pm5 MHz), and the agreement on the whole map is R2=0.91R^{2} = 0.91. The deviation is highest near the mode line, where the adiabatic elimination is less accurate because gensg_{\mathrm{ens}} is not small compared to γ0/2\gamma_{0}/2 and the three sectors share one mode. It decreases as gensg_{\mathrm{ens}} decreases, and the closed form reproduces the master equation exactly when the mode coupling is off. The analytic theory therefore captures the positions and the overall pattern, while quantitative peak heights require the full master equation.

Analytic ODMR theory of the defect-mode-driven NV ensemble

Figure 7. Analytic ODMR theory of the defect-mode-driven NV ensemble. (a) Normalised ODMR signal versus Δs/2π\Delta_{\mathrm{s}}/2\pi and Δd/2π\Delta_{\mathrm{d}}/2\pi from the analytic steady state (Bloch equations for each hyperfine sector with the drive of Eq. (3), plus the Purcell decay and frequency pull of the adiabatically eliminated defect mode). Orange dashed lines: Δd=Δs+mIAhf\Delta_{\mathrm{d}} = \Delta_{\mathrm{s}} + m_{I}A_{\mathrm{hf}}; green dashed lines: defect-mode line; vertical dashed lines: cut positions. (b) Analytic line cuts at Δs/2π=0\Delta_{\mathrm{s}}/2\pi= 0 and ±5\pm5 MHz. Parameters as in Figure 5.

Homodyne route

For the homodyne response, the closed form of Eq. (5) and the Lindblad solution agree point by point over the whole map (Figure 6a,Figure 6b), with R2>0.9999R^{2} > 0.9999 and a maximum deviation below 10−410^{-4} of the peak signal; the cut at Δc=0\Delta_{\mathrm{c}} = 0 (Figure 6c) agrees to an r.m.s. error of 2×10−72 \times10^{-7}. This agreement is expected in the weak-probe regime, where the spins stay polarised and Eq. (5) is exact for the model, and it confirms that the slopes SjS_{j} entering Eq. (7) are free of numerical artefacts. Table 1 summarises the checks.

Design levers and projected sensitivity

Figure 8a maps the projected three-edge sensitivity as a function of gensg_{\mathrm{ens}} for two spin linewidths, with the antenna critically coupled (κext=κint=κm/2\kappa_{\mathrm{ext}} = \kappa_{\mathrm{int}} = \kappa_{\mathrm{m}}/2). For Γ/2π=0.64\Gamma/2\pi= 0.64 MHz (T2∗=0.5T_{2}^{*} = 0.5 μs), the sensitivity improves steeply to

QuantitySimulationAnalyticComment
ODMR peak positions (r.m.s. difference)––0.012 MHz
Outer hyperfine line height, Δs=0\Delta_s = 00.300.41drive filtered by mode line
ODMR map agreement, R2R^2––0.91
Homodyne map agreement, R2R^2––>0.9999> 0.9999
Homodyne edge positions, Δs/2π\Delta_s/2\pi−2.18-2.18, 0, +2.18+2.18 MHzidenticalone per hyperfine line
Thermal limit, three edges8.5 pT/Hz\sqrt{\mathrm{Hz}}critical coupling, −40-40 dBm, 300 K
Projected best single edge, ηsingle\eta_{\mathrm{single}}161 pT/Hz\sqrt{\mathrm{Hz}}technical excess ×11\times11
Projected three-edge sensitivity, ηmulti\eta_{\mathrm{multi}}93 pT/Hz\sqrt{\mathrm{Hz}}Eq. (8), M=3M = 3
Multiplexing gain, ηsingle/ηmulti\eta_{\mathrm{single}}/\eta_{\mathrm{multi}}1.723=1.73\sqrt{3} = 1.73 for equal edges

Table 1. Summary of the theory–simulation validation and of the projected sensitivity. Positions and heights refer to the cuts of Figure 5b and Figure 7b; the homodyne values refer to Figure 6.

gens/2π≈0.3g_{\mathrm{ens}}/2\pi\approx0.3 MHz and reaches an optimum of 72 pT/Hz\sqrt{\mathrm{Hz}} near 0.44 MHz; beyond the optimum, the coupling begins to split the features and the slopes no longer grow. Narrowing the spin linewidth to 0.17 MHz (T2∗=1.9T_2^* = 1.9 µs), the value used in [14], improves the optimum to 19 pT/Hz\sqrt{\mathrm{Hz}} near gens/2π=0.20g_{\mathrm{ens}}/2\pi= 0.20 MHz. The dashed curves give the thermal limit of each case, 6.6 and 1.7 pT/Hz\sqrt{\mathrm{Hz}} at the respective optimals, which a readout chain without technical excess would approach.

Figure 8b varies the antenna–mode coupling κext\kappa_{\mathrm{ext}} at fixed internal mode loss (κint/2π=0.5\kappa_{\mathrm{int}}/2\pi= 0.5 MHz) and gens/2π=0.25g_{\mathrm{ens}}/2\pi= 0.25 MHz. The sensitivity has a clear optimum, but not at the textbook critical coupling κext=κint\kappa_{\mathrm{ext}} = \kappa_{\mathrm{int}} of an empty resonator. At the operating point, the spins absorb energy from the mode at a rate of about 4gens2/Γ4g_{\mathrm{ens}}^2/\Gamma, which adds to its internal loss, and the antenna is best matched to this total loss, κextopt≈κint+4gens2/Γ\kappa_{\mathrm{ext}}^{\mathrm{opt}} \approx\kappa_{\mathrm{int}} + 4g_{\mathrm{ens}}^2/\Gamma (dotted lines). This gives κextopt=1.8κint\kappa_{\mathrm{ext}}^{\mathrm{opt}} = 1.8\kappa_{\mathrm{int}} and 85 pT/Hz\sqrt{\mathrm{Hz}} for Γ/2π=0.64\Gamma/2\pi= 0.64 MHz, 9% better than critical coupling, and κextopt=4.0κint\kappa_{\mathrm{ext}}^{\mathrm{opt}} = 4.0\kappa_{\mathrm{int}} and 13 pT/Hz\sqrt{\mathrm{Hz}} for Γ/2π=0.17\Gamma/2\pi= 0.17 MHz, where the spin absorption is stronger. Away from the optimum the sensitivity degrades on both sides; an antenna coupled twenty times more weakly than κint\kappa_{\mathrm{int}} loses a factor of 8–13, more than the empty-resonator estimate, because the spin absorption increases the mismatch. A slightly over-coupled antenna is therefore preferable to an under-coupled one.

Discussion

This work shows that the cavity-coupled sensing scheme behind cavity-enhanced NV magnetometry[14] carries over to a passive magnon mode, within the same Tavis–Cummings/Lindblad model. A defect-engineered 1D YIG/CoFeB magnonic crystal supports a localised spin-wave mode inside its band gap at 2.910 GHz. When the microwave reaches the NV ensemble through this mode, the ODMR spectrum is hyperfine-resolved but strongly weighted toward the line within the mode linewidth, and the homodyne readout of the mode provides one steep dispersive edge per hyperfine line. Parameter-free checks against a plane-wave band-structure calculation and against closed-form steady states make each step traceable to the established theory.

Quantitatively, the projected three-edge sensitivity of 93 pT/Hz\sqrt{\mathrm{Hz}} is approximately eight times lower than the 12 pT/Hz\sqrt{\mathrm{Hz}} measured with the driven dielectric cavity, and the multiplexing gain of 1.72 is limited by the three edges available in a single bias field, compared with the eight or nine features of the strongly driven cavity. The analysis identifies the levers that close this gap: (i) the antenna–mode coupling, which should match the total loss of the mode including the spin absorption, so that a slightly over-coupled antenna is optimal (Figure 8b); (ii) the NV–magnon coupling gensg_{\mathrm{ens}}, set by the NV-to-film stand-off and by placing the ensemble on the defect flanks, where the dynamic field is largest (Figure 4a), with an optimum near gens/2π≈0.2g_{\mathrm{ens}}/2\pi\approx0.2–0.40.4 MHz (Figure 8a); (iii) the spin linewidth, where higher-quality diamond improves the projection to about 19 pT/Hz\sqrt{\mathrm{Hz}}; and (iv) a defect-mode linewidth comparable to 2Ahf2A_{\mathrm{hf}}, so that all three hyperfine lines are driven equally, together with lower Gilbert damping[49] of the localised mode. Unlike a driven cavity, fabrication fixes these levers, with no continuous high-power microwave drive, which favours size, weight, power, and thermal budget in chip-scale deployment.

To the best of the authors’ knowledge, this is the first physically grounded simulation showing that cavity-coupled readout in cavity-driven NV magnetometry survives replacing an actively driven photon mode with a passive, defect-localised magnon mode. The result opens a design space, termed here magnon-mediated multispectral sensing, that complements and can be tested against its cavity-driven counterpart. Natural next steps include multi-defect crystals, analogous to coupled-cavity arrays,[50, 51] for independent multiplexed readout, self-consistent micromagnetic–QuTiP co-simulation including magnon–NV back-action, and experimental verification of the predicted localised mode in a fabricated crystal integrated with a diamond NV layer. For MAD and passive geomagnetic navigation,[52, 53] a cavity-free, low-power sensor head is attractive even though MAD detection range grows only as the cube root of any sensitivity improvement[54].

Methods

Micromagnetic simulations

All micromagnetic simulations used the GPU-accelerated finite-difference code MuMax3[36], which integrates the Landau–Lifshitz–Gilbert (LLG) equation

∂m∂t=−γ1+α2[m×Beff+αm×(m×Beff)],Beff=Bext+Bexch+Bdemag,(9)\frac{\partial\mathbf{m}}{\partial t}=-\frac{\gamma}{1+\alpha^2}\left[\mathbf{m}\times\mathbf{B}_{\mathrm{eff}}+\alpha\mathbf{m}\times\left(\mathbf{m}\times\mathbf{B}_{\mathrm{eff}}\right)\right],\qquad\mathbf{B}_{\mathrm{eff}}=\mathbf{B}_{\mathrm{ext}}+\mathbf{B}_{\mathrm{exch}}+\mathbf{B}_{\mathrm{demag}}, \tag*{(9)}

for the reduced magnetisation m=M/Ms\mathbf{m}=\mathbf{M}/M_s in each cell, where γ\gamma is the gyromagnetic ratio, α\alpha the Gilbert damping constant and Beff\mathbf{B}_{\mathrm{eff}} the effective field, which contains the applied field (Zeeman), the exchange field Bexch=(2Aex/Ms)∇2m\mathbf{B}_{\mathrm{exch}}=(2A_{\mathrm{ex}}/M_s)\nabla^2\mathbf{m} and the demagnetising field (dipolar) computed by fast Fourier convolution over the whole sample. Magnetocrystalline anisotropy is neglected for both materials. The one-dimensional magnonic crystal consists of alternating YIG and CoFeB segments of widths s=300s=300 nm and d=200d=200 nm (lattice constant a=s+da=s+d) in a continuous film of thickness 25 nm on a non-magnetic GGG substrate, with a total length of about 32 μ\mum along the periodicity direction xx. A single point defect, formed by lengthening one YIG segment, is centred at x=16,250x=16{,}250 nm, so that about 32 unit cells of the pristine crystal lie on either side of it and confine the defect mode. The sample is discretised into cells of Δx×Δy×Δz=5×5×5\Delta x\times\Delta y\times\Delta z=5\times5\times5 nm3^3, smaller than the exchange lengths λex=2Aex/μ0Ms2\lambda_{\mathrm{ex}}=\sqrt{2A_{\mathrm{ex}}/\mu_0M_s^2} of both materials, so that the exchange coupling across the YIG/CoFeB interfaces and the short-wavelength modes near the band edges are resolved. Each cell is assigned the saturation magnetisation MsM_s, exchange stiffness AexA_{\mathrm{ex}} and damping α\alpha of its material (Supplementary Table S1), and MuMax3 couples neighbouring regions through the harmonic mean of their exchange stiffnesses. There are no periodic boundary conditions applied, so the domain has open boundaries.

The stray field of the on-chip permanent magnets is represented by a uniform bias Bext=101.4\mathbf{B}_{\mathrm{ext}}=101.4 mT along xx, parallel to the direction of periodicity and to the spin-wave vector, which places the crystal in backward volume geometry. Starting from a uniform magnetisation along xx, the relax() routine minimises the total micromagnetic energy, the sum of the Zeeman, exchange, and demagnetising energies, with a torque-based steepest-descent scheme, and stops when the maximum torque falls below the solver’s tolerance; no time integration takes place at this stage. The relaxed state is nearly saturated along xx, with small canting at the YIG/CoFeB interfaces and at the film ends, where magnetic surface charges produce a strongly non-uniform internal field. The static demagnetising field of this state, read from the Bdemag\mathbf{B}_{\mathrm{demag}} output, gives the stray-field maps of Supplementary Figs. S1 and S2: a periodic dipolar pattern with a magnitude of several hundred millitesla at the film surface and a local dip at the defect centre. The open boundaries produce demagnetising artefacts within about 1 μ\mum of each end; we exclude these zones from all field and mode analysis.

The spin-wave dynamics were then obtained from the relaxed state in two complementary ways. For the spectra and dispersions, a spatially uniform sinc-pulse field of 10 mT amplitude and 5 GHz cut-off, applied perpendicular to the bias, excites all modes below the cut-off with comparable amplitude. The ring-down is recorded for about 350 ns (Figure 3) at a sampling interval of 10 ps, below the 100 ps Nyquist limit of the 5 GHz band, with the physical Gilbert damping constants αYIG=2×10−4\alpha_{\mathrm{YIG}} = 2 \times10^{-4} and αCoFeB=5×10−3\alpha_{\mathrm{CoFeB}} = 5 \times10^{-3}, which set the spectral linewidths without shifting the mode frequencies; the magnetisation is stored both as a volume average and cell by cell along xx. The Fourier transform of ⟨mz(t)⟩\langle m_z(t)\rangle gives the spectral power S(f)S(f) of Figure 2b, and a two-dimensional space–time Fourier transform of the cell-resolved record mz(x,t)m_z(x,t) gives the dispersion of Figure 2a; for the crystal with the defect, the whole domain is treated as one supercell (Supplementary Note 2). The dynamic dipolar field at candidate NV positions, on the film surface, is read directly from the BdemagB_{\mathrm{demag}} output at every time step; its large static offset is subtracted and its Fourier amplitude at the defect-mode frequency flocal=2.910f_{\mathrm{local}} = 2.910 GHz is evaluated over a search window of ±5\pm5 unit cells around the defect, which fixed the NV position at x=13,755x = 13{,}755 nm. To calibrate the drive strength, a continuous-wave field of amplitude Bsignal=0.5B_{\mathrm{signal}} = 0.5 mT at flocalf_{\mathrm{local}} is applied until the response reaches a steady state; because the response is linear at this amplitude, the resulting local dynamic field at the NV position, Blocal=156B_{\mathrm{local}} = 156 μ\muT, defines the magnonic field enhancement factor E=Blocal/Bsignal=0.3125\mathcal{E} = B_{\mathrm{local}}/B_{\mathrm{signal}} = 0.3125, which relates the Rabi frequency of Eq. (3) to the antenna field.

Band-structure calculations

The plane-wave method (PWM) provides an independent calculation of the backward-volume band structure of the pristine crystal, following the formulation developed for striped Co/permalloy magnonic waveguides[30] and the plane-wave theory of magnonic crystals[19, 37, 55]. The linearised Landau–Lifshitz equation is written for small deviations m=(0,my,mz)\mathbf{m} = (0,m_y,m_z) from static magnetisation along the bias M≈Ms(x)x^\mathbf{M} \approx M_s(x)\hat{\mathbf{x}}, with harmonic time dependence eiωte^{i\omega t}. The periodic material parameters, Ms(x)M_s(x) and λex2(x)=2Aex/μ0Ms2\lambda_{\mathrm{ex}}^2(x) = 2A_{\mathrm{ex}}/\mu_0 M_s^2, are expanded in Fourier series over the reciprocal lattice vectors Gn=2πn/aG_n = 2\pi n/a, and by Bloch’s theorem the dynamic magnetisation is written as my,z(x)=∑nmy,z(Gn)ei(k+Gn)xm_{y,z}(x) = \sum_n m_{y,z}(G_n)e^{i(k+G_n)x}, with kk the Bloch wave vector in the first Brillouin zone. The magnetostatic potential of the periodic magnetisation in the 25 nm film is obtained from the magnetostatic potential of the periodic magnetisation in the 25 nm film, averaged over the thickness of the film; effective dipolar pinning at the lateral edges quantises the transverse wave vector.[56] Substituting these expansions turns the equation of motion into the matrix eigenvalue problem M^mk=iωmk\hat{M}\mathbf{m}_k = i\omega\mathbf{m}_k of size 2N×2N2N \times2N for reciprocal lattice vectors NN, which is diagonalised on a grid of kk. Positive eigenvalues give the bands fn(k)=ωn(k)/2πf_n(k) = \omega_n(k)/2\pi, and the eigenvectors give the mode profiles. The calculation truncates the expansion at N=21N = 21 harmonics (2N+1=432N+1 = 43 reciprocal lattice vectors, an 86×8686 \times86 eigenvalue problem); increasing NN further changes the bands below 4 GHz by less than 1%.

All material parameters are taken directly from the micromagnetic model, without fitting to its output. Supplementary Note 2 gives the full formalism, the sub-matrices, and a cheque against the unifobackwards-volumed-volume dispWe obtained the micromagnetic dispersion obtained without assuming any band model, from the cell-resolved ring-down mz(x,t)m_z(x,t) after the broadband pulse. A two-dimensional Fourier transform, first from position to wave vector and then from time to frequency, gives the dynamical structure factor S(k,f)=∣Fx,t[mz(x,t)]∣2S(k,f) = |\mathcal{F}_{x,t}[m_z(x,t)]|^2, whose intensity ridges trace the spin-wave bands; a Hann window in time and the exclusion of the edge zones suppress leakage and boundary artefacts, and the result is plotted on a logarithmic scale against the normalised wave vector kdkd (Figure 2a). For the pristine crystal, the PWM bands are overlaid on this map without adjustment. For the crystal containing the defect, the single-cell PWM no longer applies because the discrete translational symmetry is broken. The whole simulated domain is then treated as one supercell of length LL, which folds the bulk bands into closely spaced, nearly flat replica branches separated by about 2π/L2\pi/L (Supplementary Fig. S3)[39, 50]. A mode is classified as defect-localised only if two independent criteria hold: its frequency lies inside a gap of the pristine band structure rather than on a folded bulk band, and its spatial profile, taken from the per-cell Fourier amplitude at that frequency, decays away from the defect (Figure 4a). The mode at 2.910 GHz meets both criteria.

Master-equation simulations

QuTiP[40] solves Eqs. (1) and (2) for one bosonic mode (truncated at two Fock states for the ODMR route and three for the homodyne route) and three hyperfine sectors with Ahf=2.16A_{\mathrm{hf}} = 2.16 MHz. Collapse operators describe the mode loss γ0a\sqrt{\gamma_0}a, spin relaxation and optical repolarisation T1−1+Γp σj−\sqrt{T_1^{-1}+\Gamma_{\mathrm{p}}}\,\sigma_j^{-} and pure dephasing γϕ/2 σjz\sqrt{\gamma_{\phi}/2}\,\sigma_j^z with γϕ=1/T2∗−1/(2T1)\gamma_{\phi}=1/T_{2}^{*}-1/(2T_{1}); all rates are in μs−1\mu\mathrm{s}^{-1} and all frequencies in rad μs−1\mu\mathrm{s}^{-1}. For the ODMR route, the drive enters through Eq. (3), the observable is the mean population of ∣ms=+1⟩\lvert m_s=+1\rangle over the three sectors with equal weights, and the whole map is normalised once. For the homodyne route, a weak probe ϵ(a+a†)\epsilon(a+a^\dagger) drives the mode, the spins are kept polarised by pumping, and the observable is Re⁡Tr⁡(aρss)\operatorname{Re}\operatorname{Tr}(a\rho_{\mathrm{ss}}). Supplementary Note 4 lists all parameters.

Sensitivity projection

The reflection coefficient of the antenna at Δc=0\Delta_c=0 is r=1−κextα/ϵr=1-\kappa_{\mathrm{ext}}\alpha/\epsilon, with α\alpha from Eq. (5) and κext=κm/2\kappa_{\mathrm{ext}}=\kappa_m/2 for critical coupling. For an input power PinP_{\mathrm{in}}, a change in the field moves the reflected quadrature by Pin∣dX/dωs∣γeδB\sqrt{P_{\mathrm{in}}}\lvert dX/d\omega_s\rvert\gamma_e\delta B, where XX is the dispersive quadrature of rr. The thermal (Johnson–Nyquist) noise of one quadrature has the one-sided spectral density Sb=(kBT+hf/2)/2S_b=(k_BT+hf/2)/2[47], which gives the thermal limit ηjth=3Sb/(γePin∣dX/dωs∣max⁡,j)\eta_j^{\mathrm{th}}=\sqrt{3S_b}/(\gamma_e\sqrt{P_{\mathrm{in}}}\lvert dX/d\omega_s\rvert_{\max,j}) for each edge, with Pin=−40P_{\mathrm{in}}=-40 dBm and T=300T=300 K. The technical-noise excess of a practical readout chain is taken from ref. [14] as the ratio of its measured sensitivity (12 pT/Hz\sqrt{\mathrm{Hz}}) to the thermal limit computed in the same way for its parameters (κ/2π=0.25\kappa/2\pi=0.25 MHz assumed, gens/2π=0.26g_{\mathrm{ens}}/2\pi=0.26 MHz, Γ/2π=167\Gamma/2\pi=167 kHz, nine features), which gives 10.9. For the spectrum of Figure 6d, the mean-field Langevin equations are linearised about the steady state at each edge, with the spin detunings modulated as Δj→Δj+γeδBcos⁡(2πft)\Delta_j\to\Delta_j+\gamma_e\delta B\cos(2\pi ft). Solving the resulting linear system at each modulation frequency gives the quadrature response Yj(f)Y_j(f), which reduces to the static slope as f→0f\to0, and ηj(f)=ηj(0)∣Yj(0)∣/∣Yj(f)∣\eta_j(f)=\eta_j(0)\lvert Y_j(0)\rvert/\lvert Y_j(f)\rvert; the three edges are combined with Eq. (8). The output noise is the thermal noise of the room-temperature line, white over the band considered (Supplementary Note 5). The projection assumes that the spins respond linearly at the probe power; this requires a sufficiently large ensemble and should be verified for a specific device.

Backmatter

Supplementary information

Supplementary information contains Supplementary Notes 1–5, Supplementary Figs. S1–S3 and Supplementary Tables S1–S2.

Acknowledgements

The author acknowledges the Centre for Computational Modelling and Simulation (CCMS), National Institute of Technology Calicut, India, for access to the Madhava High-Performance Computing (HPC) cluster, and the Department of Electronics and Communication Engineering, National Institute of Technology Calicut, for the departmental workstation on which part of the simulations were carried out.

Declarations

Declarations. This research did not receive a specific grant from any funding agency in the public, commercial, or non-profit sectors.

Competing interests. The author invented Indian patent IN346145, which relates to magnonic-crystal cavity architectures. The author declares no other competing interests.

Not applicable.

Not applicable.

Data availability. The datasets generated and analysed during the current study are available from the corresponding author on reasonable request.

Materials availability. Not applicable.

Code availability. The MuMax3 input scripts, the QuTiP master-equation and sensitivity-projection code and the plane-wave band-structure code are available from the corresponding author on reasonable request.

Author contribution

N.K. conceived the study, performed the micromagnetic, plane-wave, and master-equation simulations, analysed the results, and wrote the manuscript.

Supplementary Information for “Magnonic cavity-enhanced quantum magnetometry with nitrogen-vacancy centre ensembles”

Nikhil Kumar

This Supplementary Information provides the static micromagnetic characterisation of the YIG/CoFeB magnonic crystal (Supplementary Note 1), the plane-wave method, the micromagnetic dispersion extraction and the defect-mode classification (Note 2), the derivation of the homodyne and analytic ODMR steady states (Note 3), the simulation parameters (Note 4) and the sensitivity projection (Note 5). Equations, figures and tables of the main text are cited as Eq. (n), Fig. n and Table n; supplementary items carry the prefix S.

Supplementary Note 1: Static relaxation and stray-field mapping

The built-in MuMax3[1] relax() routine brings the device to a static energy minimum under a uniform bias field Bext=101.4 mTB_{\mathrm{ext}} = 101.4\ \mathrm{mT} along xx, representing the stray field of permanent magnets on the chip (main text, Figure 1). This routine minimises the total micromagnetic energy (exchange, demagnetising, and Zeeman contributions) using an adaptive, torque-based steepest-descent scheme and stops when the maximum torque per cell falls below a preset threshold; at this stage, no time integration or excitation occurs. Supplementary Fig. S1 maps the static demagnetising (stray) field components BxB_x, ByB_y and BzB_z of the relaxed configuration, and Supplementary Fig. S2 plots the resulting field profile along the device. The static map confirms the crystal’s periodic dipolar pattern, with a magnitude of several hundred millitesla at the film surface, and shows a local field dip at the defect centre, consistent with the locally modified magnetic landscape in the defect region.

The open boundaries of the simulated domain produce demagnetisation artefacts within about 1 μm1\ \mu\mathrm{m} of each end. The analysis excludes these zones (shaded in Supplementary Fig. S2) from all field and mode analysis and searches for the NV position within ±5\pm5 unit cells of the defect.

Supplementary Note 2: Band-structure calculations and defect-mode classification

Plane-wave method

Plane-wave method details

Geometry and assumptions.

The plane-wave method (PWM) used here follows the formulation developed for striped Co/permalloy magnonic waveguides in ref. [2], which in turn adapts the plane-wave theory of three-dimensional magnonic crystals [3, 4] [5] to a film of finite thickness. The pristine crystal is periodic along xx with lattice constant a=s+da = s + d, where ss and dd are the widths of the YIG and CoFeB segments. The film has thickness t=25 nmt = 25\ \mathrm{nm} along zz and width ww along yy. The bias field H0=H0x^\mathbf{H}_0 = H_0\hat{\mathbf{x}}, the direction of periodicity and the spin-wave vector are parallel, so the crystal operates in a backward volume geometry. The model assumes that the bias saturates both materials along xx, neglects magnetocrystalline anisotropy in the small-signal dynamics and omits damping, which does not shift the eigenfrequencies to first order.

Maps of the static stray-field components and magnitude in the $x$–$z$ plane

Figure S1. Supplementary Fig. S1 Static stray field of the relaxed magnonic crystal. Maps of the static demagnetizing field components BxB_x, ByB_y and BzB_z (in mT) and of the magnitude ∣B∣|B| (in µT) in the xx–zz plane of the 1D YIG/CoFeB magnonic crystal after relaxation under Bext=101.4B_{\mathrm{ext}} = 101.4 mT applied along xx. The green dashed line marks the defect position (x=16,250x = 16{,}250 nm).

Static stray-field profile and choice of the NV position

Figure S2. Supplementary Fig. S2 Static stray-field profile and choice of the NV position. Left: full spatial profile of ∣Bstray∣|B_{\mathrm{stray}}| at the film surface; the red shaded zones near the ends are affected by open-boundary artefacts and are excluded from the analysis. Right: enlarged view of the search window around the defect, showing the selected NV position at x=13,755x = 13{,}755 nm (red dashed line) relative to the defect centre at x=16,250x = 16{,}250 nm (green dotted line).

Equation of motion.

The magnetisation obeys the Landau–Lifshitz equation.

∂M∂t=−γμ0M×Heff,Heff=H0x^+Hex+Hd,(10)\frac{\partial\mathbf{M}}{\partial t} = -\gamma\mu_0 \mathbf{M} \times\mathbf{H}_{\mathrm{eff}}, \qquad\mathbf{H}_{\mathrm{eff}} = H_0 \hat{\mathbf{x}} + \mathbf{H}_{\mathrm{ex}} + \mathbf{H}_{\mathrm{d}}, \tag*{(10)}

where γ\gamma is the gyromagnetic ratio and μ0\mu_0 the vacuum permeability. The exchange field is

Hex=∇⋅(λex2(x)∇)M,λex2=2Aexμ0Ms2,(11)\mathbf{H}_{\mathrm{ex}} = \nabla\cdot\left(\lambda_{\mathrm{ex}}^2(x)\nabla\right)\mathbf{M}, \qquad\lambda_{\mathrm{ex}}^2 = \frac{2A_{\mathrm{ex}}}{\mu_0 M_s^2}, \tag*{(11)}

with exchange stiffness AexA_{\mathrm{ex}} and saturation magnetisation MsM_s, both of which alternate between their YIG and CoFeB values. The magnetisation is the sum of a static part along the bias and a small-signal part,

M(r,t)=Ms(x)[x^+m(r,t)],m=(0,my,mz),∣m∣≪1,\mathbf{M}(\mathbf{r},t)=M_s(x)[\hat{\mathbf{x}}+\mathbf{m}(\mathbf{r},t)],\qquad\mathbf{m}=(0,m_y,m_z),\qquad|\mathbf{m}|\ll1,

where m\mathbf{m} is the magnetisation of the small-signal normalised to the local MsM_s. The demagnetising field splits in the same way into a static part and a dynamic part Hd=H(r)+h(r,t)\mathbf{H}_{\mathrm{d}}=\mathbf{H}(\mathbf{r})+\mathbf{h}(\mathbf{r},t), which in the magnetostatic approximation satisfy[6]

∇×H=0,∇⋅(H+Msx^)=0,∇×h=0,∇⋅(h+Msm)=0.(12)\nabla\times\mathbf{H}=0,\qquad\nabla\cdot(\mathbf{H}+M_s\hat{\mathbf{x}})=0,\qquad\nabla\times\mathbf{h}=0,\qquad\nabla\cdot(\mathbf{h}+M_s\mathbf{m})=0. \tag*{(12)}

For harmonic dynamics ∝eiωt\propto e^{i\omega t}, keeping terms to first order in m\mathbf{m}, the linearised equation of motion reads

iωmy=−γμ0[Hi(x)mz−hztot],iωmz=γμ0[Hi(x)my−hytot].(13)i\omega m_y=-\gamma\mu_0\left[H_i(x)m_z-h_z^{\mathrm{tot}}\right],\qquad i\omega m_z=\gamma\mu_0\left[H_i(x)m_y-h_y^{\mathrm{tot}}\right]. \tag*{(13)}

where Hi(x)=H0+Hx(x)H_i(x)=H_0+H_x(x) is the static internal field, including the static demagnetising field HxH_x produced by the magnetic charges at the YIG/CoFeB interfaces, and htot\mathbf{h}^{\mathrm{tot}} is the sum of the dynamic exchange and dipolar fields.

Plane-wave expansion.

Every periodic material parameter is expanded over the reciprocal lattice vectors Gn=2πn/aG_n=2\pi n/a. For the two-component step profile with the YIG segment centred at the origin,

Ms(G)={MsYf+MsC(1−f),G=0,(MsY−MsC)fsin⁡(Gs/2)Gs/2,G≠0,f=sa.(14)M_s(G)= \begin{cases} M_s^{\mathrm{Y}}f+M_s^{\mathrm{C}}(1-f), & G=0,\\ \left(M_s^{\mathrm{Y}}-M_s^{\mathrm{C}}\right)f\frac{\sin(Gs/2)}{Gs/2}, & G\ne0, \end{cases} \qquad f=\frac{s}{a}. \tag*{(14)}

and λex2(G)\lambda_{\mathrm{ex}}^2(G) follows in the same way, where the superscripts Y and C denote YIG and CoFeB. By Bloch’s theorem, the small-signal magnetisation takes the form of

my,z(r)=∑Gmy,z(G)ei(k+G)xeikyy.(15)m_{y,z}(\mathbf{r})=\sum_Gm_{y,z}(G)e^{i(k+G)x}e^{ik_y y}. \tag*{(15)}

with the Bloch wave vector kk in the first Brillouin zone, −π/a≤k≤π/a-\pi/a\le k\le\pi/a. Across the width, effective dipolar pinning at the lateral edges quantises the transverse wave vector as ky=rπ/wk_y=r\pi/w, with rr an integer that depends on the type of pinning[2] [7]; the bands in Figure 2a of the main text use the lowest-width mode. Across the 25 nm thickness, we take the dynamic profile as uniform, which is accurate for the lowest-thickness mode of a thin film compared with the exchange and dipolar lengths that matter at these frequencies[8].

Static and dynamic dipolar fields.

The magnetostatic potential of the periodic magnetisation follows from Eq. (12) with continuity of the potential and of the normal induction at the film surfaces[2] [9]. Inside the film, the static field along xx has the profile

Hx(x,z)=−∑G≠0Ms(G)[1−cosh⁡(∣G∣z)e−∣G∣t/2]eiGx,H_x(x,z)=-\sum_{G\ne0}M_s(G)\left[1-\cosh(|G|z)e^{-|G|t/2}\right]e^{iGx},

whose average thickness gives the following.

Hx(G)=−Ms(G)[1−S(∣G∣)](G≠0),Hx(0)=0,S(q)=1−e−qtqt.(16)H_x(G)=-M_s(G)[1-S(|G|)]\quad(G\ne0),\qquad H_x(0)=0,\qquad S(q)=\frac{1-e^{-qt}}{qt}. \tag*{(16)}

This field is largest in magnitude in the low-MsM_s YIG segments next to the CoFeB stripes, so that the internal field Hi(x)H_i(x) is strongly non-uniform. For the dynamic field, each Bloch component with in-plane wave vector

qn=(k+Gn)2+ky2q_n=\sqrt{(k+G_n)^2+k_y^2}

produces, after averaging over the thickness,

hz(Gn)=−S(qn)Mz(Gn),hy(Gn)=−[1−S(qn)]ky2qn2My(Gn).(17)h_z(G_n)=-S(q_n)\mathcal{M}_z(G_n),\qquad h_y(G_n)=-[1-S(q_n)]\frac{k_y^2}{q_n^2}\mathcal{M}_y(G_n). \tag*{(17)}

where My,z(Gn)=∑jMs(Gn−Gj)my,z(Gj)\mathcal{M}_{y,z}(G_n)=\sum_j M_s(G_n-G_j)m_{y,z}(G_j) are the Fourier coefficients of dynamic magnetisation Ms(x)my,z(x)M_s(x)m_{y,z}(x). The component outside the plane hzh_z is the thin-film depolarising field, which tends to −Msmz-M_sm_z for qnt→0q_nt\to0, while the component inside the plane hyh_y vanishes for a uniform mode across the width (ky=0k_y=0).

Eigenvalue problem.

Substituting Eqs. (11), (14)–(17) into Eq. (13) and collecting the coefficient of each plane wave turns the spin-wave problem into the matrix eigenvalue problem[2, 3]

M^mk=iωmk,mk=[my(G1),…,my(GN),mz(G1),…,mz(GN)]T,M^=(0M^yzM^zy0)(18)\hat{M}\mathbf{m}_{k}=i\omega\mathbf{m}_{k},\qquad\mathbf{m}_{k}=\left[m_{y}(G_{1}),\ldots,m_{y}(G_{N}),m_{z}(G_{1}),\ldots,m_{z}(G_{N})\right]^{T},\qquad\hat{M}=\begin{pmatrix}0&\hat{M}^{yz}\\\hat{M}^{zy}&0\end{pmatrix} \tag*{(18)}

with the sub-matrices;

Mijyz=−γμ0[Hi(Gi−Gj)+Eij+S(qi)Ms(Gi−Gj)],M_{ij}^{yz}=-\gamma\mu_{0}\left[H_{i}(G_{i}-G_{j})+E_{ij}+S(q_{i})M_{\mathrm{s}}(G_{i}-G_{j})\right],
Mijzy=γμ0[Hi(Gi−Gj)+Eij+[1−S(qi)]ky2qi2Ms(Gi−Gj)],M_{ij}^{zy}=\gamma\mu_{0}\left[H_{i}(G_{i}-G_{j})+E_{ij}+\left[1-S(q_{i})\right]\frac{k_{y}^{2}}{q_{i}^{2}}M_{\mathrm{s}}(G_{i}-G_{j})\right],
Eij=∑l[(k+Gi)(k+Gl)+ky2]λex2(Gi−Gl)Ms(Gl−Gj),(19)E_{ij}=\sum_{l}\left[(k+G_{i})(k+G_{l})+k_{y}^{2}\right]\lambda_{\mathrm{ex}}^{2}(G_{i}-G_{l})M_{\mathrm{s}}(G_{l}-G_{j}), \tag*{(19)}

where Hi(G)=H0δG,0+Hx(G)H_{i}(G)=H_{0}\delta_{G,0}+H_{x}(G). The exchange term EijE_{ij} is the Fourier representation of Eq. (11); because it is written for the full magnetisation Ms(x)[x^+m]M_{\mathrm{s}}(x)[\hat{\mathbf{x}}+\mathbf{m}], it carries the exchange coupling across the YIG/CoFeB interfaces without separate boundary conditions. For a uniform film (N=1N=1, ky=0k_{y}=0), Eq. (18) reduces to the backward-volume dispersion ω2=γ2μ02(H0+λex2Msk2)(H0+λex2Msk2+S(k)Ms)\omega^{2}=\gamma^{2}\mu_{0}^{2}\left(H_{0}+\lambda_{\mathrm{ex}}^{2}M_{\mathrm{s}}k^{2}\right)\left(H_{0}+\lambda_{\mathrm{ex}}^{2}M_{\mathrm{s}}k^{2}+S(k)M_{\mathrm{s}}\right), which tends to the Kittel frequency for k→0k\to0 and decreases with kk[6, 8], a useful cheque of implementation.

Numerical procedure.

The calculation proceeds as follows: (i) build the Fourier coefficients of MsM_{\mathrm{s}} and λex2\lambda_{\mathrm{ex}}^{2} from Eq. (14) for ∣n∣≤nmax⁡|n|\leq n_{\max}, so that N=2nmax⁡+1N=2n_{\max}+1; (ii) compute the static internal field from Eq. (16); (iii) for each kk on a grid across the first Brillouin zone, assemble M^\hat{M} from Eq. (19) and diagonalise it; (iv) keep the eigenvalues with positive frequency, fn(k)=ωn(k)/2πf_{n}(k)=\omega_{n}(k)/2\pi, which form the bands, and use the eigenvectors to reconstruct the spatial mode profiles through Eq. (15). Because the step profiles of Eq. (14) have Fourier coefficients that decay only as 1/n1/n, and because the contrast in MsM_{\mathrm{s}} between CoFeB and YIG is large, nmax⁡n_{\max} increases until the bands below 4 GHz change by less than 1%; in ref. [2] about 30 reciprocal lattice vectors were sufficient for the bands, and the static field needed more harmonics, converging as a damped oscillation in the number of vectors. The present calculation uses nmax⁡=30n_{\max}=30. The calculation uses only the geometry and material parameters of the micromagnetic model (Supplementary Table S1), without fitting to the micromagnetic output, and applies only to the strictly periodic crystal.

Physical content of the bands.

Two features of the PWM bands in fig:2a of the main text follow directly from this formulation. First, the periodic modulation of MsM_{\mathrm{s}} and AexA_{\mathrm{ex}} couples plane waves that differ by a reciprocal lattice vector, and Bragg scattering opens gaps at the centre and boundary of the zone; the gap widths grow with the contrast between the two materials and depend on the filling fraction ff, as shown for the Co/permalloy waveguide in ref. [2]. Second, the strongly non-uniform static internal field of Eq. (16) makes low-frequency spin waves concentrate their amplitude in the regions of low internal field, where they form standing waves with nearly zero group velocity. They appear as nearly flat bands below about 1.5 GHz in Fig. 2a, the same mechanism that produces the flat low-frequency bands of the striped waveguide[2]. At higher frequencies, the bands become dispersive and the gap between 2.5 and 3.0 GHz opens, hosting the defect mode. This combined PWM and micromagnetic strategy follows the approach used previously for striped waveguides, magnonic rings, and antidot crystals with a ring defect[2] [10, 11].

Micromagnetic dispersion extraction

To obtain a dispersion relation rather than a single-point spectrum, a broadband pulse that is flat in frequency up to its cut-off excites the relaxed crystal, driving all spin-wave modes in that band simultaneously and with comparable amplitude. The solver records the magnetisation in every cell along the direction of periodicity, and a two-dimensional Fourier transform, first from space to wave vector and then from time to frequency, converts the m(x,t)m(x,t) record into the dynamical structure factor S(k,ω)S(k,\omega), whose intensity ridges trace the dispersion without assuming any band model. Beyond the bands reproduced by the PWM (main text, Figure 2a), the micromagnetic map shows a few sharp features near 2.4 and 2.55 GHz and a diffuse continuum at about 1.8–2.3 GHz. The linear, single-mode PWM does not capture these features. They are consistent with higher-order width or thickness modes, which lie outside the lowest-mode ansatz of Eq. (15), or with nonlinear spin-wave processes.

Defect-supercell analysis

A single point defect removes the discrete translational symmetry assumed in the single-unit-cell PWM calculation. The analysis therefore adopts the standard defect-supercell approach, which treats the entire simulated domain, including the bulk crystal and the defect, as one large effective unit cell.[11, 12] This folds the bulk bands into a dense set of closely spaced, nearly flat replica branches separated by about 2π/L2\pi/L in wave vector for a supercell of length LL (Supplementary Fig. S3). Two independent criteria distinguish a genuine defect-localised mode from the folded bulk replicas.[13–15] First, the mode frequency must lie inside a gap of the pristine band structure rather than on a folded bulk band. Second, its spatial profile must be exponentially confined to the defect rather than extended across the crystal, as the per-cell mode profile in fig:4a of the main text shows.

Dispersion of the 1D YIG/CoFeB crystal containing a point defect

Figure S3. Dispersion of the crystal containing a point defect. Dispersion of the 1D YIG/CoFeB crystal with a single point defect, computed over the whole simulated domain with the defect-supercell method. Breaking the strict periodicity folds the bulk bands into a dense manifold of closely spaced, nearly flat replica branches (most prominent between 1.3 and 1.9 GHz) separated by about 2π/L2\pi/L for a supercell of length LL. A mode is classified as defect-localised if its frequency lies within a bulk gap of the pristine dispersion (main text, Figure 2a) and its real-space profile is confined to the defect.

Supplementary Note 3: Homodyne and analytic ODMR steady states

Both start from the Tavis–Cummings Hamiltonian of Eq. (1), in which each 14N{}^{14}\mathrm{N} projection mI∈{−1,0,+1}m_I \in\{-1, 0, +1\} forms an independent two-level system on the ms=0↔ms=+1m_s = 0 \leftrightarrow m_s = +1 transition, coupled with strength gensg_{\mathrm{ens}} to the defect magnon mode aa of the loss rate γ0=κm\gamma_0 = \kappa_m. They differ in what drives the system and in what is measured. In the homodyne route, a weak probe drives the mode and the reflected microwave is detected, so the spins stay close to their polarised ground state; in the ODMR route, a stronger drive reaches the spins through the mode, and the population transferred out of ms=0m_s = 0 is detected optically.

Homodyne response

For the homodyne readout, a weak coherent probe of amplitude ϵ\epsilon and frequency ωp\omega_{\mathrm{p}} is coupled into the mode through the antenna. In the frame rotating at ωp\omega_{\mathrm{p}}, the Hamiltonian reads [16]

Hp=Δca†a+∑j=−1+1[Δj2σjz+gens(aσj++a†σj−)]−ϵ(a+a†)(20)H_{\mathrm{p}}=\Delta_{\mathrm{c}}a^\dagger a+\sum_{j=-1}^{+1}\left[\frac{\Delta_j}{2}\sigma_j^z+g_{\mathrm{ens}}\left(a\sigma_j^+ + a^\dagger\sigma_j^-\right)\right]-\epsilon\left(a+a^\dagger\right) \tag*{(20)}

where Δc=ωc−ωp\Delta_{\mathrm{c}}=\omega_{\mathrm{c}}-\omega_{\mathrm{p}} is the detuning of the mode from the probe and Δj=ωj−ωp=Δs+mIAhf+Δc\Delta_j=\omega_j-\omega_{\mathrm{p}}=\Delta_{\mathrm{s}}+m_I A_{\mathrm{hf}}+\Delta_{\mathrm{c}} is the detuning of sector jj, with Δs=ωs−ωc\Delta_{\mathrm{s}}=\omega_{\mathrm{s}}-\omega_{\mathrm{c}} set by the bias field. The probe frequency is the swept variable, so Δc\Delta_{\mathrm{c}} and all three Δj\Delta_j change together while the spin frequencies themselves stay fixed; omitting Δc\Delta_{\mathrm{c}} from Δj\Delta_j would make the spins follow the probe and produce spurious features. Treating the mode and the spin coherences as amplitudes driven by the probe and by vacuum or thermal noise inputs aina^{\mathrm{in}} and bjinb_j^{\mathrm{in}} gives the quantum Langevin equations [17].

dadt=−(iΔc+γ02)a−igens∑jσj−+iϵ+γ0ain(21)\frac{da}{dt}=-\left(i\Delta_{\mathrm{c}}+\frac{\gamma_0}{2}\right)a-i g_{\mathrm{ens}}\sum_j\sigma_j^-+i\epsilon+\sqrt{\gamma_0}a^{\mathrm{in}} \tag*{(21)}
dσj−dt=−(iΔj+Γ2)σj−+igensPa+Γbjin(22)\frac{d\sigma_j^-}{dt}=-\left(i\Delta_j+\frac{\Gamma}{2}\right)\sigma_j^-+i g_{\mathrm{ens}}Pa+\sqrt{\Gamma}b_j^{\mathrm{in}} \tag*{(22)}

in which P=⟨σjz⟩≃−1P=\langle\sigma_j^z\rangle\simeq-1 is the spin polarisation maintained by optical pumping and Γ=2/T2∗\Gamma=2/T_2^* is the full spin linewidth, including relaxation, dephasing, and inhomogeneous broadening of the ensemble.

In steady state, the time derivatives vanish, and Eq. (22) gives each spin coherence in terms of the mode amplitude, σj−=igensPa/(iΔj+Γ/2)\sigma_j^-=i g_{\mathrm{ens}}Pa/(i\Delta_j+\Gamma/2). Physically, every hyperfine sector behaves as a small resonator that is driven by the mode and reacts back on it. Substituting this result into Eq. (21) and taking the mean, in which the noise inputs vanish, gives the closed form of (5) of the main text. The spins enter only through the term gens2P∑j(iΔj+Γ/2)−1g_{\mathrm{ens}}^2P\sum_j(i\Delta_j+\Gamma/2)^{-1}, whose imaginary part pulls the mode frequency and whose real part adds loss; each pull changes sign as a hyperfine line crosses the mode, which produces the three steep edges of Figure 6c.

The probe amplitude coupled into the mode is ϵ=κextamw\epsilon=\sqrt{\kappa_{\mathrm{ext}}}a^{\mathrm{mw}}, where amwa^{\mathrm{mw}} is the incident field, and κext\kappa_{\mathrm{ext}} is the antenna–mode coupling rate. By input–output theory the reflected field is aout=amw−κextαa^{\mathrm{out}}=a^{\mathrm{mw}}-\sqrt{\kappa_{\mathrm{ext}}}\alpha, so the reflection coefficient of the antenna is r=1−κextα/ϵr=1-\kappa_{\mathrm{ext}}\alpha/\epsilon, the quantity used for the sensitivity projection of the Supplementary Note 5. In the weak-probe limit, the spins remain polarised and PP stays at −1-1, so the closed form is exact for the model; the point-by-point agreement with the master equation in Figure 6a,Figure 6b (R2>0.9999R^2>0.9999) confirms this and shows that the slopes entering the sensitivity are free of numerical artefacts.

Analytic ODMR spectrum

In the ODMR route, the antenna drives the defect mode, and the transverse field of the mode drives each hyperfine sector with the Rabi frequency Ω(Δd)\Omega(\Delta_{\mathrm{d}}) of (3) of the main text and a detuning δj=Δs+mIAhf−Δd\delta_j=\Delta_{\mathrm{s}}+m_I A_{\mathrm{hf}}-\Delta_{\mathrm{d}} from the drive. The mode also couples the spins to its own loss channel. When gensg_{\mathrm{ens}} is small compared to γ0/2\gamma_0/2, the mode responds faster than the spins and can be eliminated adiabatically, leaving each sector with two additional terms, a Purcell decay rate and a mode-induced frequency pull,

ΓP,j=gens2γ0Δsj2+γ02/4,δL,j=gens2ΔsjΔsj2+γ02/4,Δsj=Δs+mIAhf.(23)\Gamma_{\mathrm{P},j}=\frac{g_{\mathrm{ens}}^2\gamma_0}{\Delta_{\mathrm{sj}}^2+\gamma_0^2/4},\qquad \delta_{\mathrm{L},j}=\frac{g_{\mathrm{ens}}^2\Delta_{\mathrm{sj}}}{\Delta_{\mathrm{sj}}^2+\gamma_0^2/4},\qquad \Delta_{\mathrm{sj}}=\Delta_{\mathrm{s}}+m_I A_{\mathrm{hf}}. \tag*{(23)}

The Purcell decay is largest when the sector is resonant with the mode (Δsj≈0\Delta_{\mathrm{sj}}\approx0) and broadens the line; the pull vanishes at resonance, is largest at ∣Δsj∣≈γ0/2|\Delta_{\mathrm{sj}}|\approx\gamma_0/2 and pushes the line away from the mode frequency. Each sector is then an ordinary driven two-level system, and the steady state of its Bloch equations gives the population of ∣ms=+1⟩|m_s=+1\rangle,

P1,j=12Xj(δj+δL,j)2+G2,j2+Xj,Xj=Ω2G2,jG1,j,(24)P_{1,j}=\frac{1}{2}\frac{X_j}{(\delta_j+\delta_{\mathrm{L},j})^2+G_{2,j}^2+X_j},\qquad X_j=\Omega^2\frac{G_{2,j}}{G_{1,j}}, \tag*{(24)}

with the population decay rate G1,j=T1−1+Γp+ΓP,jG_{1,j}=T_1^{-1}+\Gamma_{\mathrm{p}}+\Gamma_{\mathrm{P},j}, the coherence decay rate G2,j=G1,j/2+γϕG_{2,j}=G_{1,j}/2+\gamma_{\phi} and the pure dephasing rate γϕ=1/T2∗−1/(2T1)\gamma_{\phi}=1/T_2^*-1/(2T_1). Equation (S15) contains saturation through XjX_j, which increases as Ω2\Omega^2 and limits P1,jP_{1,j} to 12\frac{1}{2}, and power broadening, which widens the line as Ω\Omega increases. The ODMR signal of Figure 7 is the average 13∑jP1,j\frac{1}{3}\sum_j P_{1,j}, with equal weights, normalised once over the whole map.

This analytic spectrum has a clear range of validity. Without the mode (gens=0g_{\mathrm{ens}} = 0), the Purcell and pull terms vanish, and Eq. (24) reproduces the master-equation solution exactly. With the mode, it is approximate. For gens/2π=0.25g_{\mathrm{ens}}/2\pi= 0.25 MHz and γ0/2π=1.0\gamma_0/2\pi= 1.0 MHz, it reproduces the peak positions to within 0.012 MHz r.m.s. and the overall pattern of the simulated map (R2=0.91R^2 = 0.91), but it overestimates the heights of the outer hyperfine lines near the mode line (0.41 instead of 0.30 at Δs=0\Delta_s = 0). The adiabatic elimination neglects the coherent back-action of the mode on the driven spins and the mode-mediated coupling between the three sectors, both of which matter when gensg_{\mathrm{ens}} is not small compared to γ0/2\gamma_0/2. The deviation decreases as gensg_{\mathrm{ens}} decreases; therefore, the analytic theory fixes the positions and overall structure of the spectrum, while the full master equation determines the quantitative peak heights.

Simulation parameters

Supplementary Table S1 lists the parameters used in the micromagnetic, plane-wave, and master-equation simulations. The NV–magnon coupling and the defect-mode linewidth are representative values; their influence on the sensitivity, and that of the antenna coupling, is mapped in Figure 8 of the main text.

ParameterValueNotes
YIG stripe width, ss300 nm
CoFeB stripe width, dd200 nma=s+da = s + d
Film thickness, tt25 nm
Cell size, Δx×Δy×Δz\Delta x \times\Delta y \times\Delta z5×5×55 \times5 \times5 nm3^3
Simulated length≈32,000\approx32{,}000 nmopen boundaries
Defect position16,250 nm
YIG: MsM_s, AexA_{\mathrm{ex}}, α\alpha140 kA m−1^{-1}, 3.7 pJ m−1^{-1}, 1×10−41 \times10^{-4}YIG refs. [18, 19]
CoFeB: MsM_s, AexA_{\mathrm{ex}}, α\alpha1250 kA m−1^{-1}, 15 pJ m−1^{-1}, 4.2×10−34.2 \times10^{-3}Co40_{40}Fe40_{40}B20_{20}, ref. [20]
Bias field, BextB_{\mathrm{ext}}101.4 mTalong xx (magnet stray field)
Excitationsinc pulse, 10 mT, 5 GHz cut-offuniform
PWM harmonics, nmax⁡n_{\max}30N=2nmax⁡+1=61N = 2n_{\max} + 1 = 61
Defect-mode frequency, fmodef_{\mathrm{mode}}2.910 GHzMuMax3
Field enhancement, E=Blocal/Bsignal\mathcal{E} = B_{\mathrm{local}}/B_{\mathrm{signal}}0.3125CW, Bsignal=0.5B_{\mathrm{signal}} = 0.5 mT
NV zero-field splitting, fZFSf_{\mathrm{ZFS}}2.87 GHz
Hyperfine splitting, AhfA_{\mathrm{hf}}2.16 MHzequal mIm_I weights
Rabi frequency on the mode resonance, Ω0/2π\Omega_0/2\pi0.10 MHzEq. (3) of the main text
Defect-mode linewidth, κm/2π=γ0/2π\kappa_m/2\pi= \gamma_0/2\pi1.0 MHzrepresentative
NV–magnon coupling, gens/2πg_{\mathrm{ens}}/2\pi0.25 MHzrepresentative
Ensemble dephasing time, T2∗T_2^*0.5 μ\musΓ/2π=0.64\Gamma/2\pi= 0.64 MHz
Longitudinal relaxation time, T1T_11 ms
Optical repolarisation rate, Γp\Gamma_p0.1 μ\mus−1^{-1}
Homodyne probe amplitude, ϵ/2π\epsilon/2\pi0.01 MHzlinear response

Table S1. Simulation parameters.

Sensitivity projection

Thermal limit

At the operating point Δc=0\Delta_c = 0, the antenna reflects the probe with coefficient r(ωs)=1−κextα/ϵr(\omega_s) = 1 - \kappa_{\mathrm{ext}} \alpha/\epsilon (Supplementary Note 3). A field change δB\delta B shifts the spin frequency by γeδB\gamma_e \delta B and moves the dispersive quadrature X=Im⁡rX = \operatorname{Im} r of the reflected wave by Pin∣dX/dωs∣γeδB\sqrt{P_{\mathrm{in}}} \lvert dX/d\omega_s\rvert\gamma_e \delta B, in units of W\sqrt{\mathrm{W}}, for an input power PinP_{\mathrm{in}}. The standard quantum limit (Johnson–Nyquist) and vacuum noise in one quadrature has the one-sided spectral density Sb=(kBT+hf/2)/2S_b = (k_B T + hf/2)/2 [21]. The minimum detectable field per unit bandwidth on edge jj is therefore

ηjth=3SbγePin∣dX/dωs∣max⁡,j(25)\eta_j^{\mathrm{th}} = \frac{\sqrt{3}\sqrt{S_b}}{\gamma_e \sqrt{P_{\mathrm{in}}}\lvert dX/d\omega_s\rvert_{\max,j}} \tag*{(25)}

and the edges combine through Eq. (8) of the main text. For an empty resonator with internal loss rate κint\kappa_{\mathrm{int}}, the reflected signal is largest at critical coupling, κext=κint\kappa_{\mathrm{ext}} = \kappa_{\mathrm{int}}, and degrades by (κint+κext)2/(4κintκext)(\kappa_{\mathrm{int}} + \kappa_{\mathrm{ext}})^2/(4\kappa_{\mathrm{int}}\kappa_{\mathrm{ext}}) away from it[22]. With the spins present, the mode loses additional energy to the spin ensemble. Near a steep edge, where the operating spin feature lies within about Γ/2\Gamma/2 of the mode, Eq. (5) of the main text adds a loss rate of order 4gens2/Γ4g_{\mathrm{ens}}^{2}/\Gamma, so that the effective internal loss becomes κint+4gens2/Γ\kappa_{\mathrm{int}} + 4g_{\mathrm{ens}}^{2}/\Gamma and the optimum antenna coupling moves to

κextopt≈κint+4gens2Γ.(26)\kappa_{\mathrm{ext}}^{\mathrm{opt}} \approx\kappa_{\mathrm{int}} + \frac{4g_{\mathrm{ens}}^{2}}{\Gamma}. \tag*{(26)}

The complete calculation of Figure 8b, in which the slopes are recomputed from Eq. (5) with κm=κint+κext\kappa_{\mathrm{m}} = \kappa_{\mathrm{int}} + \kappa_{\mathrm{ext}} for each κext\kappa_{\mathrm{ext}}, places the optima at κext/κint=1.78\kappa_{\mathrm{ext}}/\kappa_{\mathrm{int}} = 1.78 and 3.98 for Γ/2π=0.64\Gamma/2\pi= 0.64 and 0.17 MHz, in agreement with Eq. (26) (1.79 and 3.98). Weak coupling is penalised more strongly than for an empty resonator: at κext=0.05κint\kappa_{\mathrm{ext}} = 0.05\kappa_{\mathrm{int}} the sensitivity degrades by a factor of 8 and 13 relative to critical coupling, compared to 5.5 of the empty resonator formula.

Technical-noise excess

A practical homodyne chain (low-noise amplifier, mixer, local oscillator and data acquisition) adds noise above the thermal limit. Its size is estimated from ref. [16]: Eq. (25) evaluated with the parameters of that work (−40-40 dBm probe, gens/2π=0.26g_{\mathrm{ens}}/2\pi= 0.26 MHz, Γ/2π=167\Gamma/2\pi= 167 kHz, nine features, and an assumed cavity linewidth of 0.25 MHz) gives 1.1 pT/Hz\sqrt{\mathrm{Hz}}, whereas the measured sensitivity is 12 pT/Hz\sqrt{\mathrm{Hz}}, a technical-noise excess of 10.9. The projection for the magnonic device applies the same excess, which assumes a readout chain of comparable quality.

Frequency dependence of the sensitivity

To obtain the sensitivity as a function of the frequency ff of the field to be measured (Figure 6d of the main text), the field is taken to oscillate, δB(t)=δBcos⁡(2πft)\delta B(t) = \delta B\cos(2\pi f t), so that each spin detuning is modulated, Δj→Δj+γeδBcos⁡(2πft)\Delta_j \to\Delta_j + \gamma_{\mathrm{e}}\delta B\cos(2\pi f t). Writing the mode and spin amplitudes as their steady-state values at the operating point (Δc=0\Delta_{\mathrm{c}} = 0, Δs\Delta_{\mathrm{s}} on the steepest edge) plus small deviations x=(δa,δσ−1,δσ0,δσ+1)\mathbf{x} = (\delta a,\delta\sigma_{-1},\delta\sigma_{0},\delta\sigma_{+1}), Eqs. (21) and (22) give, to first order,

dxdt=−A^x+b γeδB(t),bj=−iσˉj,(27)\frac{d\mathbf{x}}{dt}=-\hat{A}\mathbf{x}+\mathbf{b}\,\gamma_{\mathrm{e}}\delta B(t),\qquad b_j=-i\bar{\sigma}_j, \tag*{(27)}

where A^\hat{A} contains the mode and spin decay rates and detunings and the couplings ±igens\pm ig_{\mathrm{ens}}, and σˉj\bar{\sigma}_j is the steady-state coherence of sector jj. For a modulation e−i2πfte^{-i2\pi f t}, the solution is x=(A^−i2πf)−1b\mathbf{x}=(\hat{A}-i2\pi f)^{-1}\mathbf{b}. The response of the dispersive quadrature to the real field is therefore

Yj(f)=Hj(f)−Hj∗(−f)2i,Hj(f)=[(A^−i2πf)−1b]a,(28)Y_j(f)=\frac{H_j(f)-H_j^{*}(-f)}{2i},\qquad H_j(f)=\left[(\hat{A}-i2\pi f)^{-1}\mathbf{b}\right]_a, \tag*{(28)}

which reduces to the static slope dX/dωsdX/d\omega_{\mathrm{s}} as f→0f\to0. The output noise of one quadrature is the thermal and vacuum noise of the room-temperature line, Sb=(kBT+hfc/2)/2S_b=(k_{\mathrm{B}}T+hf_{\mathrm{c}}/2)/2, which is white at the modulation frequencies considered because they are far below the 2.9 GHz carrier. The sensitivity of edge jj is then ηj(f)=ηjth∣Yj(0)∣/∣Yj(f)∣\eta_j(f)=\eta_j^{\mathrm{th}}|Y_j(0)|/|Y_j(f)|, multiplied by the technical-noise excess for the projected sensitivity, and the edges combined through Eq. (8) of the main text. The response is flat while ff is small compared with the linewidths of the coupled system, so the sensitivity is constant up to about 100 kHz, and it falls above a −3-3 dB bandwidth of about 360 kHz, set by the spin linewidth Γ\Gamma and the mode linewidth κm\kappa_{\mathrm{m}}. Near 2 MHz the modulation sidebands of one hyperfine line reach its neighbours, separated by Ahf=2.16A_{\mathrm{hf}}=2.16 MHz, which produces small features in η(f)\eta(f). Technical 1/f1/f noise and pickup at low frequencies, present in any real readout, are not part of the model.

QuantityValueNotes
Edge positions, Δs/2π\Delta_s/2\pi−2.18-2.18, 0, +2.18+2.18 MHzFigure 6c of the main text
Thermal limit, single edge14.7 pT/Hz\sqrt{\mathrm{Hz}}Eq. (25)
Thermal limit, three edges8.5 pT/Hz\sqrt{\mathrm{Hz}}Eq. (8), M=3M = 3
Technical-noise excess10.9from ref. [16]
Projected best single edge161 pT/Hz\sqrt{\mathrm{Hz}}
Projected three edges93 pT/Hz\sqrt{\mathrm{Hz}}multiplexing gain 1.72
Sensitivity bandwidth (−3-3 dB)≈360\approx360 kHzFigure 6d
Optimum for Γ/2π=0.64\Gamma/2\pi= 0.64 MHz72 pT/Hz\sqrt{\mathrm{Hz}} at gens/2π≈0.44g_{\mathrm{ens}}/2\pi\approx0.44 MHzFigure 8a
Optimum for Γ/2π=0.17\Gamma/2\pi= 0.17 MHz19 pT/Hz\sqrt{\mathrm{Hz}} at gens/2π≈0.20g_{\mathrm{ens}}/2\pi\approx0.20 MHzFigure 8a
Optimum antenna coupling, Γ/2π=0.64\Gamma/2\pi= 0.64 MHzκext=1.8κint\kappa_{\mathrm{ext}} = 1.8\kappa_{\mathrm{int}}, 85 pT/Hz\sqrt{\mathrm{Hz}}Figure 8b
Optimum antenna coupling, Γ/2π=0.17\Gamma/2\pi= 0.17 MHzκext=4.0κint\kappa_{\mathrm{ext}} = 4.0\kappa_{\mathrm{int}}, 13 pT/Hz\sqrt{\mathrm{Hz}}Figure 8b

Table S2. Inputs and results of the sensitivity projection (critical coupling, Pin=−40P_{\mathrm{in}} = -40 dBm, T=300T = 300 K).

References

  1. [1]Vansteenkiste, A. et al. The design and verification of MuMax3. AIP Adv. 4, 107133 (2014).DOI
  2. [2]Kumar, N. & Prabhakar, A. Spin wave dispersion in striped magnonic waveguide. IEEE Trans. Magn. 49, 1024–1028 (2013).DOI
  3. [3]Krawczyk, M. & Puszkarski, H. Plane-wave theory of three-dimensional magnonic crystals. Phys. Rev. B 77, 054437 (2008).DOI
  4. [4]Puszkarski, H. & Krawczyk, M. Magnonic crystals—the magnetic counterpart of photonic crystals. Solid State Phenom. 94, 125–134 (2003).DOI

Paper details

vlnc:W_uz7nt7xx
Version
v1 · latest