betaFeedback

WorksPhysics and Astronomy

Delving into the depths of NGC 3783 with XRISM VI. Evidence for a failed wind based on Fe xxv absorption line variability

Abstract

NGC 3783 exhibits a prominent Fe XXV absorption trough in the time-averaged XRISM/Resolve spectrum. To investigate its short-term variability, we present a time-resolved analysis of the Fe XXV absorption line during the continuous 10-day observation. We divided the resolved absorption profile into five fixed velocity intervals and measured their normalized equivalent widths in 19 time-resolved spectra. Three velocity intervals exhibit significant equivalent-width (EW) variability. Two velocity intervals respond differently to low- and high-flux states with less emission line contamination. The time-dependent photoionisation modelling is unable to reproduce the most significant observed EW variation (3.5 σ3.5 \, σ), possibly owing to uncertainties in the assumed initial equilibrium state, which prevent a precise density measurement. Instead, using photoionisation calculations and assuming the high-density limit, we derive approximate constraints on the ionisation parameters of the two relevant components. The low-velocity component (-320 to -680 km/s) shows a delayed inverse response, indicating a high ionisation parameter, while its relatively short lag timescale indicates a relatively high density and a distance upper limit of 0.05 pc. In contrast, the high-velocity component (-680 to -1040 km/s) manifests a positive response with a longer lag to the ionising continuum, implying a relatively low ionisation parameter. This component appears to be less dense, with an inferred distance upper limit of 0.25 pc. The low-velocity component is consistent with a failed wind, as its outflow velocity is below the local escape velocity, whereas the high-velocity component lies near the escape threshold. Together with the lower-ionisation failed wind detected in 2001, this supports a multiphase failed-wind scenario in the unobscured state of NGC~3783 over more than two decades.

Introduction

Active galactic nuclei (AGNs) commonly exhibit ionized outflows spanning a broad range of column densities, ionisation states, and velocities, from classical warm absorbers (WAs) to highly ionized Fe K absorbers detected in the X-ray band [59, 68]. These outflows are closely linked to the accretion–ejection processes operating near the central supermassive black hole (SMBH) and are widely regarded as an important manifestation of AGN feedback [60, 12, 13, 31]. In particular, highly ionized Fe K absorption lines provide a direct probe of the innermost circumnuclear gas, where the wind launching and acceleration processes are expected to occur [59, 15].

The Resolve microcalorimeter onboard XRISM delivers a spectral resolution of approximately 4.5 eV full width at half maximum (FWHM) at 6 keV [58, 26]. This high resolution enables precise measurements of highly ionized outflows in the Fe K band, such as Fe xxv and Fe xxvi lines, as demonstrated by early XRISM observations of several AGN, including PDS 456 (XRISM Collaboration et al. 2025; Xu et al. 2025), NGC 3783 [36, 47], NGC 4151 [64, 41], Mrk 279 [40], MCG−6−30−15 [7], PG 1211+143 [44], NGC 3516 [18], NGC 1365 [69], Cen A [25] and NGC 5548 [39]. These observations have revealed outflows with velocities ranging from a few hundred km s−1^{-1} to a substantial fraction of the speed of light, spanning a wide range of radial distances and often exhibiting complex, clumpy structures.

Time-resolved analysis of XRISM/Resolve spectra provides a powerful means of diagnosing variability in Fe K absorbers on daily, and even sub-day, timescales. It offers insight into the acceleration mechanism for a detected transient Ultra-fast Outflow— flow (UFO) during a soft flare in NGC 3783 (Gu et al. 2025). In NGC 4051, the Fe K absorber changes within less than a day, possibly because of two separate absorbers or one accelerating outflow [50]. In NGC 3516, three highly ionized Fe K absorbers vary on timescales of tens of kiloseconds, likely due to changes in ionisation and/or clumps crossing the line of sight [18]. Overall, Resolve time-resolved spectroscopy is a powerful tool for characterizing rapidly varying outflows under photoionisation-equilibrium models.

Time-dependent photoionisation modelling of AGN outflows, by diagnosing the response of the ionisation state of the absorbing outflows to changes in the ionizing continuum, uses the recombination timescale (trect_{\mathrm{rec}}) of the outflow to constrain its electron number density (nen_{\mathrm{e}}) by ne∝1/trecn_{\mathrm{e}} \propto1/t_{\mathrm{rec}} [28, 46, 19]. The subsequent spectral-timing technique, which is based on the advanced time-dependent photoionisation models [53, 54], has been used to measure or place a precise constraint on density/distance for low-ionisation WAs [55] (Li et al. 2023; Li et al. 2025) with ionisation parameter [57, 28]

ξ=LionnHr2,(1)\xi= \frac{L_{\mathrm{ion}}}{n_{\mathrm{H}}r^{2}}, \tag*{(1)}

where LionL_{\mathrm{ion}} is the 1–1000 Ryd ionizing luminosity, nHn_{\mathrm{H}} is the hydrogen density, rr is the distance of the gas to the ionizing source. One interesting resulting application is the identification of a failed wind candidate visible through the Fe Unresolved Transition Arrays (UTA, [2]) in NGC 3783 (Li et al. 2025). Such constraints can help break the degeneracy among different launching mechanisms [9, 10, 11, 56, 13, 14, 42, 43, 48] and clarify the connection between UFOs and warm absorbers [59, 31].

Here we present a study of the variability of the highly ionized Fe-K absorbers (Fe xxv at 6.7 keV) from the first long observation of NGC 3783 led by XRISM in 2024. NGC 3783 is one of the best-studied Seyfert 1 galaxies in high-resolution X-ray spectroscopy and has long served as a benchmark source exhibiting multiple-phase ionized AGN outflows with a broad range of velocities [24, 23, 30, 45, 1, 35, 36, 70]. XRISM observed the source continuously for 10 days, and the corresponding time-averaged spectrum reveals a prominent Fe xxv absorption feature around 6.7 keV composed of three different photoionized components [36]. With CCD spectral resolution, the strong 6.7 keV absorption line is also clearly detected in the time-averaged XMM-Newton/PN spectra by Reeves et al. [49], while the depth of the feature appears to vary over a timescale of 10510^{5} s, being strongest when the continuum flux is higher. In grating spectra, the Fe xxv resonance line is hard to detect due to the relatively small effective area of Chandra/HETG [23]. With the unprecedented energy resolution and enhanced effective area in the Fe K band of Resolve, the time-averaged spectrum of NGC 3783 provides us with a high signal-to-noise ratio, especially important for studying the Fe xxv strength in the greatest detail.

The Fe xxv absorption line of NGC 3783 is the most prominent and relatively broad absorption feature in the Fe-K band, enabling us to study the variability of the multiple kinematic components of this line. Furthermore, using state-of-the-art photoionisation modelling in SPEX version 3.08.01 [20, 21], the density and distance of the highly ionized Fe xxv absorbers are expected to be constrained more precisely, thereby advancing our understanding of its origin. This paper is organized as follows. In Sect. 2, we describe the time-resolved analysis of the Resolve spectra of Fe xxv and the derived variability for multiple kinematic velocity components. In Sect. 3, we model the detected variability with time-dependent photoionisation modelling (tpho, Rogantini et al. 2022). We discuss and summarize our results in Sect. 4 and Sect. 5, respectively.

Observation data analysis and results

NGC 3783 was observed by XRISM for 10 days, from July 18–27 in 2024. The coordinated multiwavelength campaign also included XMM-Newton, Chandra, NuSTAR, Swift, NICER, and HST, see Xrism Collaboration et al. (2025) for details. In this work, we primarily use data from XRISM (Resolve 439 ks, Xtend 372 ks) and Swift/XRT (long-term monitoring with 30 data points) for our time-resolved spectra analysis and time-dependent photoionisation modelling. We adopt the same spectral dataset as in our previous NGC 3783 series (Papers I–V) and refer the reader to those papers for full details of the data reduction and analysis procedures of XRISM [36, 70] (Xrism Collaboration et al. 2025; Gu et al. 2025; Li et al. 2026).

The main goal of this paper is to investigate the response of the Fe xxv absorption line to the ionizing flux variations in NGC 3783. Due to the closed gate valve of the XRISM/Resolve instrument, that instrument is insensitive to soft X-rays. Therefore, we present the XRISM/Xtend light curves in the 0.3–0.7 keV and 3.0–6.0 keV bands in the top panel of Figure 1 to illustrate the intrinsic source variability. These light curves were used as a reference for defining the time intervals for time-resolved spectral analysis. The boundaries were placed at transitions between rise, peak, decay, and valley phases, while ensuring sufficient counts in the Fe xxv line. All phases are resolved in the light curve and may sample different stages of the absorber response. Seven major flux peaks can be distinguished (labelled A – G in green); the strongest, here labelled "C", is the prominent soft-X-ray flare, which has been linked to a transient Ultra-Fast Outflow launching episode by Gu et al. (2025).

Figure 1. XRISM/Xtend light curves of NGC 3783 in the soft (0.3–0.7 keV; red) and hard (3–6 keV; blue) bands. The vertical dashed lines delimit the 19 time intervals used for the time-resolved spectral analysis, with each interval labelled according to the local flux morphology. The letters A–G mark the seven main variability episodes. One XRISM orbit corresponds to 5747.37 s. Orbit 0 corresponds to 2024 July 17 at 19:43:44 UTC, marking the start of the first Chandra observation in the 2024 XRISM campaign.

The 19 time intervals shown in Figure 1, each lasting approximately half a day, ensure a sufficient signal-to-noise ratio for investigating variability in the Fe xxv resonance absorption line. Shorter intervals are not useful for this purpose, because the signal-to-noise ratio in the energy band of the absorption line becomes too poor. For each time interval, we extracted a Resolve spectrum, yielding 19 time-resolved spectra for the analysis in Sect. 2.2.

Local fit to the time-averaged Fe XXV velocity profile

For the time-averaged Fe xxv velocity profile shown in Figure 2, we divided the central region and the red and blue wings of the absorption profile into five adjacent energy bins, each approximately 8 eV wide and corresponding to a velocity interval of 360 km s−1^{-1}. The adopted width of 360 km/s for the five line components is a compromise between resolution and significance. Narrower components lead to strong correlations between the equivalent widths of neighbouring components, and, consequently, to poorly constrained line properties.

Figure 2. The Fe xxv velocity profile of NGC 3783 derived from the 439 ks time-averaged XRISM/Resolve spectrum obtained in 2024. The data-to-model ratio (black) shows the residual Fe xxv absorption relative to the baseline model of Mehdipour et al. [36], from which the Fe xxv absorption components were removed. The red line represents the local best-fit model of the local spectrum, convolved with the instrument, using the model with five piecewise-constant transmission components as described in the text.

We used the spectral model of Mehdipour et al. [36] as our baseline, with one modification. Mehdipour et al. [36] modelled the time-averaged Resolve spectrum with a power-law continuum, emission-line components, and six photoionized xabs transmission components in a global fit. Each xabs component describes the time-averaged properties of a corresponding warm absorber component.1 The Fe xxv absorption trough studied here receives its principal contributions from three of these components (see Sect. 3.1). To sample the resolved asymmetric Fe xxv absorption trough, we removed the Fe xxv contributions of these three xabs components and modelled the absorption trough locally in each velocity interval with the transmission, T(E)T(E), constant and given by T(E)=1−fcovT(E) = 1 - f_{\mathrm{cov}}.

In the local fit to the time-averaged Fe xxv spectrum, we kept the parameters of all remaining model components adopted from Mehdipour et al. [36] unchanged. For each component, only the covering factor fcovf_{\mathrm{cov}} was fitted. Under our adopted opaque-bin configuration, fcovf_{\mathrm{cov}} is approximately equal to the normalized equivalent width (EW, see Sect. 2.2). The five components therefore measure the absorption strength within the five fixed velocity intervals. The normalized EWs derived from the time-averaged spectrum are adopted as reference values for the corresponding intervals (see the second row of Table 1). The best-fitting local model is shown by the red curve in Figure 2.

Velocity range(a)(b)(c)(d)(e)
vav^{a} (km/s)[+400, +40][+40, −320][−320, −680][−680, −1040][−1040, −1400]
mean b^{b}0.10±0.050.10 \pm0.050.11±0.050.11 \pm0.050.56±0.040.56 \pm0.040.43±0.050.43 \pm0.050.27±0.050.27 \pm0.05
EW1_1−0.31±0.21-0.31 \pm0.210.89±0.100.89 \pm0.100.17±0.120.17 \pm0.12
EW2d_2^{d}0.46±0.160.46 \pm0.160.26±0.160.26 \pm0.160.69±0.100.69 \pm0.10
∣EW1−EW2∣\lvert\mathrm{EW}_1-\mathrm{EW}_2\rvert0.77±0.260.77 \pm0.260.63±0.180.63 \pm0.180.51±0.150.51 \pm0.15
SeS^{e}3.0 σ3.0\ \sigma3.5 σ3.5\ \sigma3.4 σ3.4\ \sigma
Robs=EWweakEWstrongfR_{\mathrm{obs}} = \frac{\mathrm{EW}_{\mathrm{weak}}}{\mathrm{EW}_{\mathrm{strong}}}^{f}EW2EW1=0.30±0.18\frac{\mathrm{EW}_2}{\mathrm{EW}_1}=0.30\pm0.18EW1EW2=0.25±0.18\frac{\mathrm{EW}_1}{\mathrm{EW}_2}=0.25\pm0.18

Table 1. Statistical properties of the Fe xxv equivalent-width variability in five velocity intervals.

Time-resolved Resolve spectra and Fe xxv analysis

Each of the 19 time-resolved Resolve spectra was analysed over the same five velocity intervals shown in Figure 2, within the Fe xxv energy range of 6.668–6.708 keV. The local model parameters were configured according to the following assumptions.

We assume that the intensities of the narrow, broad and relativistic emission lines are constant in time. Allowing the intensity of the narrow and broad line components to vary does not affect the local continuum level near the Fe xxv absorption line. Since the amplitude of the relativistic line component is small and limited in energy band width, even potential variations in its intensity do not affect the derived continuum level more than a few percent and therefore can be ignored as far as the equivalent width determination of the absorption line is concerned. We also

Notes. The Fe xxv line profile was divided into five velocity intervals based on spectral binning. a^{a} Velocity interval. b^{b} The mean EW derived from the time-averaged spectrum. c^{c} The mean EW within gray shaded area, see Figure 3. d^{d} The mean EW within the blue-shaded area. e^{e} The significance level of the variability, calculated with ∣EW1−EW2∣\lvert\mathrm{EW}_1-\mathrm{EW}_2\rvert. f^{f} RobsR_{\mathrm{obs}} is the observed ratio.

Figure 3. Top: the Xtend light curve in the 0.3 − 10 keV energy band for reference. Panels (a) − (e): the Resolve EW of the Fe xxv absorption line as a function of time for five fixed velocity intervals in NGC 3783. The normalized EW, i.e. wiw_i in each given time bin, is defined such that wi=0w_i = 0 corresponds to no absorption, whereas wi=1w_i = 1 corresponds to complete absorption within a bin. During fitting, wiw_i is allowed to extend beyond this physical interval to avoid boundary-biased estimates. The gray and blue shaded regions indicate the time intervals used to calculate the weighted means of normalized EW (EW1_1 and EW2_2) listed in the third and fourth rows of Table 1. The colored dashed lines show the normalized EW measured from the time-averaged spectrum (see Sect. 2.1). The black vertical line marks the peak time of flare C.

assume that all absorption components remain constant during the observation, except for the Fe xxv resonance absorption line. We verified that even if some of the other absorption lines were variable, the effect on the derived continuum level at Fe xxv is completely negligible.

Consequently, the covering factors, whose physical range is 0≤fcov≤10 \leq f_{\mathrm{cov}} \leq1, are the only free parameter used to characterize the line absorption. A covering factor of zero means no absorption, whereas a covering factor of one corresponds to complete absorption within the velocity bin. We formally allow for values smaller than zero or larger than one in order to obtain proper error estimates on the line depth. A negative value therefore does not imply emission or a negative physical covering factor; it means the measured flux lies statistically above the adopted local continuum.

We then fit each time interval spectrum with the covering factor of the five Fe xxv components and the photon index and normalisation of the main power law component as free parameters. The five absorption components span the velocity range from +400 to −1400 km/s. The results of our fit for all line components are shown in Figure 3.

In this configuration, the fitted covering factor measures the absorption depth within each velocity bin and is reported as the normalized equivalent width (EW, hereafter), with its 1σ uncertainty. Panels (a)–(e) of Figure 3 show the temporal evolution of the Fe xxv absorption in the five velocity intervals. The coloured horizontal line in each panel marks the reference normalized EW measured from the time-averaged spectrum. Values above and below this level represent stronger and weaker absorption, respectively. To quantify the variability, we calculated the weighted mean normalized EW for selected phases of stronger and weaker absorption. We summarize these results in Table 1.

The observed Fe xxv variability

Velocity interval (c), spanning −320 to −680 km s−1^{-1}, covers the core of the Fe xxv absorption trough (Figure 2). The Fe xxv absorption strength varies from near-complete absorption (time interval 4) to negligible absorption (time interval 8) during the softest phase of the soft X-ray flare (Figure 3). After reaching its minimum in interval 8, the EW increases until interval 11 and then shows a decreasing trend as the luminosity slowly increases. The EW is high during orbits 20–40 (gray panel in Figure 3), with a value of 0.89±0.100.89 \pm0.10, whereas it decreases to 0.26±0.160.26 \pm0.16 during orbits 50–70 (blue panel in Figure 3). This corresponds to a difference of 0.63±0.180.63 \pm0.18, significant at the 3.5 σ3.5\,\sigma level. This indicates that the Fe xxv absorption line responds to the luminosity variation, especially around the soft flare event C.

In velocity interval (d), covering −680 to −1040 km/s, the blue wing of the absorption line, the EW exhibits significant variability around a mean value of EW = 0.43. However, the amplitude is lower and it exhibits an opposite trend to that in interval (c). In interval (b), for velocities +40 to −320 km/s, the EW evolves from no absorption (EW ≈ 0) to nearly complete absorption within the velocity bin (EW ≈ 1) during flare C, showing significant EW variability. However, its apparent relationship with the continuum is uncertain because this interval is strongly affected by the adjacent Fe xxv emission line. We therefore do not interpret its variability further.

In general, in Figure 3, our analysis clearly shows that the Fe xxv resonance absorption strength in the different velocity intervals exhibits different behaviours. The EW in interval (d) reaches its maximum around the ninth time interval, whereas that in velocity interval (c) reaches its minimum at approximately the same epochs. The absorption in velocity intervals (c) and (d) shows opposite responses to the same variation in the light curve, suggesting contributions from physically distinct absorber components. We note that interval (c), corresponding to the velocity range of −320 to −680 km/s, and forming the deepest part of the Fe xxv absorption trough, exhibits the most significant variability when the flux changes.

Time-dependent photoionisation modelling: tpho

The observed variability of the Fe xxv absorption line may be driven by changes in the illuminating X-ray flux. The response of the photoionized outflow depends on both the characteristic variability timescale of the incident light curve and the recombination timescale of the plasma (e.g., [19, 53] (Li et al. 2023)). The time-dependent photoionisation ({tpho2tpho^2}) model implemented in SPEX v3.08.01 ([21]) tracks the ionisation evolution of the gas in response to X-ray luminosity variations ([53]). To model the absorber response with tpho, we adopt an SED, a driving light curve, and an initial photoionisation-equilibrium state for each absorber.

SED. NGC 3783 was observed in an unobscured state in 2024 comparable to that of 2001, with no evidence of a high-column-density obscurer along the line of sight ([38]).

For the 2024 XRISM observation, Mehdipour et al. [36] adopted the 2001 SED to model the warm-absorber properties. For consistency, we use the same SED as Mehdipour et al. [36] and refer to it as the “normal SED”. We neglect possible changes in the SED during flare C because the available data do not constrain its evolution reliably.

Light curve. We extracted XRISM/Xtend light curves in the 0.3–1.5, 1.5–10, and 0.3–10 keV bands to match the corresponding Swift/XRT bands. In the same energy range, Swift/XRT provides longer-term monitoring, including seven epochs simultaneous with Xtend. We cross-calibrate and scale the Swift/XRT light curve to match Xtend by a scaling factor of 3.2 ± 0.5, 3.0 ± 0.8 and 3.5 ± 0.5 for soft, hard and total band, respectively. During flare C, we fitted the peak of the Xtend light curve with a linear baseline plus a Gaussian profile, yielding peak orbits of 52.6±0.2, 50.0±0.2, 51.2±0.1 in the soft (0.3–1.5 keV), hard (1.5–10 keV), and total bands (0.3–10 keV), respectively. We plot the light curve in the energy band of 0.3 − 10 keV in Figure 4. We use it as input light curve for tpho in our current calculation. In the combined Xtend+Swift light curve, we exclude Swift data points that overlap in time with the Xtend coverage. We then take the mean count rate (the horizontal dashed line of Figure 4) of the combined light curve as the first point of the tpho driving light curve. We assume a photoionisation equilibrium state at the start of the calculations.

Figure 4. The combined Swift/XRT and XRISM/Xtend light curve in the energy band of 0.3–10 keV. The horizontal dashed line indicates the mean count rate of the combined light curve, adopted as the initial flux of the time-dependent calculation.

Initial photoionisation equilibrium state. We assume that the variability detected in the Fe xxv absorption line (Sect. 2) arises from changes in the physical absorber components identified in the time-averaged spectral analysis of Mehdipour et al. [36]. Mehdipour et al. [36] modelled the time-averaged Resolve spectrum with six photoionised xabs transmission components. For a specified ionising SED, xabs calculates the transmission of a slab of gas. Its principal fitted parameters include NHN_{\mathrm{H}}, log⁡ξ\log\xi, the outflow velocity, and the turbulent velocity (Table 2). In that study, the Fe xxv absorption features were attributed to three warm-absorber components: Comp. A1, B, and C. We take the parameters from the best-fitting time-averaged spectrum by Mehdipour et al. [36] for this initial state.

Componentvoutv_{\mathrm{out}} (km s−1^{-1})log⁡ξ\log\xiNHN_{\mathrm{H}} (102510^{25} m−2^{-2})σv\sigma_v (km s−1^{-1})
A1−590-5903.193.193.63.64040
B−700-7002.962.961515420420
C−1170-11703.563.5699250250

Table 2. Adopted parameters of the Fe xxv absorber components from the time-averaged analysis of Mehdipour et al. [36], used as initial inputs to the tpho calculations.

Time-dependent FeXXV ion concentration calculations

For the components A1, B, and C, we performed separate tpho calculations. Each calculation used an energy grid spanning 0.01–10⁸ eV with a logarithmic step size of 0.1 dex. The combined 0.3–10 keV light curve (Figure 4) drives the time-dependent ionisation evolution over 5.2 Ms. For each component, the corresponding log⁡ξ\log\xi and outflow velocity listed in Table 2 were used to define the initial equilibrium state. Figure 5 shows the predicted Fe xxv ionic concentrations of components A1, B, and C during the XRISM observation. The Comp. A1 and Comp. C vary inversely with the light curve, whereas Comp. B responds positively to the light curve. Comp. B shows a stronger temporal ionic response than Comp. A1 for the adopted initial ionisation states. Its larger column density and broader velocity profile also cause it to contribute strongly to the model EW in interval (c).

Figure 5. Time-dependent Fe xxv ion concentration predicted by tpho for a gas density of 1016.0 m−310^{16.0}\ \mathrm{m}^{-3}. The gray, blue and orange curves represent Comp. A1, B and C, respectively. The black dotted curve shows the input light curve from Figure 4.

For each absorber component, the tpho calculations are performed over a range of gas densities and yield the corresponding time-dependent Fe xxv ionic concentration. The resulting ionic concentration (hereafter, Cion(t)C_{\mathrm{ion}}(t)) was averaged for each of the 19 time intervals. Using Nion=NH×CionN_{\mathrm{ion}} = N_{\mathrm{H}} \times C_{\mathrm{ion}}, we convert the predicted CionC_{\mathrm{ion}} into the ionic column NionN_{\mathrm{ion}} for each component, where NHN_{\mathrm{H}} is the hydrogen column density of the warm absorber component (see Table 2). We insert these Fe ionic column densities in the slab model of SPEX in order to compute the transmission of the absorber. The slab3 model calculates the transmission through a thin layer of gas from independently specified ionic column densities, a velocity width σv\sigma_v, and a bulk velocity shift (Kaastra et al. [22]).

Comparison with the observed variability

We apply this procedure to velocity interval (c), which exhibits the most significant variability in Figure 3. As shown in Figure 6, absorption in this interval is dominated by components A1 and B. For a grid of values for the column densities of components A1 and B, we show the combined EW in Figure 7. The combined EW increases with the ionic column density of either component. At high column densities, however, the EW approaches unity and becomes less sensitive to further increases in column density because the absorption line becomes saturated. Component B makes a substantial contribution to velocity interval (c) because of its relatively large column density and broad velocity profile, which distributes its absorption across several adjacent velocity intervals. However, a larger velocity width does not by itself imply stronger saturation, since the line-centre optical depth scales approximately as Nion/σvN_{\mathrm{ion}}/\sigma_v. For each of the 19 time intervals, the pair (NFe xxv,A1N_{\mathrm{Fe\,xxv,A1}}, NFe xxv,BN_{\mathrm{Fe\,xxv,B}}) predicted by tpho is mapped onto this grid to obtain the corresponding model EW.

Figure 7. The normalized model EW for velocity range (c) as a function of the respective Fe xxv column densities of Comp. A1 and B.

Figure 6. The time-averaged spectral model (in red) of Mehdipour et al. [36] identifies the contributions of components A1, B, and C to the Fe xxv absorption profile; their best-fitting parameters are used to initialise the tpho calculations. The vertical lines represent the same velocity intervals as in Figure 2.

Figure 8 shows the Fe xxv ionic column densities predicted by tpho for components A1 and B over the 19 time intervals (left panels) and compares the corresponding tpho model EWs with the observed EWs from Figure 3 in velocity interval (c) (right panels). In the lower-density case (upper row), the long ionisation and recombination timescales produce smooth variations in the ionic column densities. Consequently, the model EW remains nearly constant and does not reproduce the observed variability. In the higher-density case (lower row), component B responds more rapidly to the ionising continuum and dominates the predicted EW variability, whereas component A1 varies more slowly. Nevertheless, the high-density model still does not reproduce the full amplitude of the observed variability. We explored different density combinations for these two components, but no satisfactory solution was found within the model, even in the high-density cases.

Figure 8. Time evolution of the Fe xxv absorption line for two density cases. Left panels: the calculated ionic column density in m−2^{-2} of Fe xxv for Comp. B and A1. Right panels: the combined EW of Comp.B and A1 for velocity range (c) as computed from the column densities in the left panels (red points and line), compared with the observed values (black). Top row: low density (101210^{12} m−3^{-3}). Bottom row: high density (101610^{16} m−3^{-3}).

Discussion

The time-resolved analysis of the Fe xxv absorption line shows different behaviour for different velocity intervals. As shown in Sect. 2.3, the variability in velocity interval (c) is opposite to that observed in interval (d), suggesting that the absorption cannot be described by a single uniform component and that the narrow spectral-bin analysis traces changes in physically distinct absorber components. For this analysis, we treat intervals (c) and (d) as tracing separate physical components.

Limitations of our tpho modelling

As noted in § 3.1, our time-dependent photoionisation modelling with tpho was unable to explain the observed spectral line variability. In this section, we discuss the possible reasons for this limitation.

First, the tpho calculations assume that the SED retains the shape measured during the unobscured 2001 epoch, while its normalisation follows the observed light curve (Figure 4). To compare the overall SED normalisations in 2001 and 2024, we calculated the 1–1000 Ryd (13.6 eV–13.6 keV) ionising luminosity using the 2001 normal-state SED of Mehdipour et al. [38] and the best-fitting 2024 broad-band model of Zhao et al. [70]. The two estimates agree within their uncertainties, indicating comparable integrated ionising luminosities.

Although HST and XMM-Newton constrain the UV and soft X-ray sides of the ionising SED, respectively, no instrument in the campaign directly covers most of the EUV continuum. Moreover, the temporal coverage of HST and XMM-Newton is insufficient to reconstruct an independent broad-band SED for each of the 19 time intervals (Xrism Collaboration et al. (2025)). We therefore adopt the well-constrained 2001 SED as a reference shape and vary its normalisation according to the observed light curve. Possible spectral-shape changes during flare C remain a systematic uncertainty in the tpho calculations. The energy-dependent evolution of the same flare, attributed to coronal magnetic reconnection (Vardi et al. [61]), suggests that scaling a fixed SED with a single light curve may not fully represent the ionising continuum.

Second, the tpho predictions depend on the adopted initial ionisation state and absorber decomposition. We initialise the calculations using the six-component solution of Mehdipour et al. [36], whereas Zhao et al. [70] identified eight components from a joint Resolve and XMM-Newton/RGS analysis. The absorber structure may therefore be more complex: component B may comprise unresolved narrower components, while A1 is constrained mainly by one spectral bin near −600 km s−1^{-1}(Fig. 6). Uncertainties in the initial ionisation parameters, velocity widths, and component decomposition may thus contribute to the disagreement between tpho prediction and the observation. A broader profile for A1 and a narrower profile for B could alter their relative contributions to interval (c), however, exploring such a broad parameter space goes beyond the scope of this paper.

Finally, uncertainties in the underlying emission model may affect the measured absorption variability. The model includes a broad Fe xxv emission line that affects the red wing of the absorption line (Mehdipour et al. [36]). The inclusion or exclusion of this emission line can also affect the fit to the time-averaged spectrum in the local energy band. The Fe xxv emission may originate from the X-ray BLR (Bianchi & Matt [4]; Bianchi et al. [5]) and may vary significantly during the flare decay phase (Gu et al. (2025)). The model also includes a separate relativistically broadened emission component. A preliminary analysis by Li et al. (2026) suggests that the equivalent width of this component varies by less than 30%, except during the strong soft flare. Because both emission components contribute weakly in the local absorption band, their variability is unlikely to dominate the measured absorption but is treated as a systematic uncertainty.

Density lower limit for the Fe xxv absorbers

The stronger variability of the Fe xxv line is expected to occur for high densities. For low densities, the line will remain constant in EW. Therefore we focus here on high densities. In this limit, at each time interval the ionisation state of the absorber is photoionisation equilibrium with the instantaneous time-dependent luminosity.

Estimating the ionisation parameter from the EW ratio

In Table 1, we calculated the observed EW ratio for velocity intervals (c) and (d) to quantify the change in absorption strength during flare C. We did not calculate the ratio for interval (b), nor further constrain its log⁡ξ\log\xi, because contamination from the Fe xxv emission line introduces substantial uncertainty. For a given absorber component in the optically thin regime, the equivalent width is proportional to the ionic column density. If NHN_{\mathrm{H}}, the covering fraction, elemental abundance, and velocity broadening remain constant, then Nion∝CionNHN_{\mathrm{ion}} \propto C_{\mathrm{ion}}N_{\mathrm{H}}. Therefore,

EWweakEWstrong=Nion,weakNion,strong=Cion,weakCion,strong,(2)\frac{\mathrm{EW}_{\mathrm{weak}}}{\mathrm{EW}_{\mathrm{strong}}} = \frac{N_{\mathrm{ion,weak}}}{N_{\mathrm{ion,strong}}} = \frac{C_{\mathrm{ion,weak}}}{C_{\mathrm{ion,strong}}}, \tag*{(2)}

where we compare two epochs with a weak and strong line. This proportionality applies only in the optically thin regime. Saturation will affect the stronger line more than the weaker, making this EW ratio bigger than in the optical thin limit.

To constrain the ionisation parameter of the Fe xxv absorbers, we need to determine how the equilibrium Fe XXV ionic fraction varies with log⁡ξ\log\xi. The SPEX pion model4 calculates the equilibrium ionic fractions as a function of the ionisation parameter [37]. We run a grid of pion models for different log⁡ξ\log\xi, using the 2001 unobscured SED. The resulting Fe xxv ionic fraction distribution is presented in the top panel of Figure 9, peaking at log⁡ξ≈3.1\log\xi\approx3.1. Since ξ\xi scales with luminosity as ξ∝Lion/(nHr2)\xi\propto L_{\mathrm{ion}}/(n_{\mathrm{H}}r^2), changes in LionL_{\mathrm{ion}} will modify ξ\xi and therefore the Fe xxv ionic fraction. LionL_{\mathrm{ion}} was enhanced by about 25% during flare C corresponding to an increase of 0.10 in log⁡ξ\log\xi. The resulting CFe xxv_{\mathrm{Fe\,xxv}} ratio of the before and after enhanced luminosity, defined as,

Figure 9. Top: Equilibrium Fe xxv ionic concentration scaled to its peak value as a function of log⁡ξ\log\xi, calculated using the 2001 normal SED. Bottom: Ratio = CFe xxv(log⁡ξ+0.10)/CFe xxv(log⁡ξ)C_{\mathrm{Fe\,xxv}}(\log\xi+ 0.10)/C_{\mathrm{Fe\,xxv}}(\log\xi) in magenta and the inverse in blue, both corresponding to a 25% increase in ionising luminosity.

Rbeforeafter=CFe xxv(log⁡ξ+0.10)CFe xxv(log⁡ξ),(3)R_{\mathrm{before}}^{\mathrm{after}} = \frac{C_{\mathrm{Fe\,xxv}}(\log\xi+ 0.10)}{C_{\mathrm{Fe\,xxv}}(\log\xi)}, \tag*{(3)}

is plotted in Figure 9, together with its inverse i.e. RafterbeforeR_{\mathrm{after}}^{\mathrm{before}}.

For comparing the observed EW ratios (RobsR_{\mathrm{obs}}) with the model ratio, with the relationship shown in Eq. (2), we defined the model EW ratio by CFe xxv_{\mathrm{Fe\,xxv}} of weak to strong:

Rmodel(log⁡ξ)=Cion, weakCion, strong.(4)R_{\mathrm{model}}(\log\xi) = \frac{C_{\mathrm{ion,\,weak}}}{C_{\mathrm{ion,\,strong}}}. \tag*{(4)}

Because the weak phase follows flare C in interval (c), its observed ratio is compared with RbeforeafterR_{\mathrm{before}}^{\mathrm{after}}, shown by the magenta curve in Figure 9. In interval (d), the weak phase precedes the strong phase, so its ratio is compared with RafterbeforeR_{\mathrm{after}}^{\mathrm{before}}, shown by the blue curve.

For interval (c), the measured ratio of 0.30±0.180.30 \pm0.18 is compared with the declining magenta curve. The central and lower values lie near or below the minimum model ratio and therefore do not provide a unique constraint on log⁡ξ\log\xi. A significant decrease in the CFe xxv_{\mathrm{Fe\,xxv}} begins at log⁡ξ≳3.2\log\xi\gtrsim3.2 as the ionising flux increases. At log⁡ξ≳3.5\log\xi\gtrsim3.5, CFe xxvi_{\mathrm{Fe\,xxvi}} dominates over CFe xxv_{\mathrm{Fe\,xxv}}. Requiring a detectable Fe xxv fraction and significant variability, we adopt 3.2≲log⁡ξ≲3.53.2 \lesssim\log\xi\lesssim3.5.

For interval (d), the ratio of 0.25±0.180.25 \pm0.18 places the absorber on the rising blue ratio curve with log⁡ξ<3.05\log\xi< 3.05. Its central ratio and upper limit derive log⁡ξ=2.65,2.95\log\xi= 2.65, 2.95, respectively. Because the Fe xxv fraction is negligible at the central value, we adopt only the approximate upper limit log⁡ξ≲2.95\log\xi\lesssim2.95.

As indicated before, there may be some uncertainty in these limits on log⁡ξ\log\xi due to systematic effects. We have tested this for interval (c). Detailed spectral modelling of the line profile shows that due to the variability the Fe xxv column density (see Eq. (2)) decreases by a factor of ∼3\sim3 while the EW decreases only by a factor of ∼2\sim2, but accounting for it does not change the derived limits on log⁡ξ\log\xi significantly. More importantly, we have adopted a change of about 25% in luminosity during Flare C, corresponding to a change of 0.10 in log⁡ξ\log\xi. However, when we inspect the light curve of Figure 1, we see that in the soft X-ray band (0.3–0.7 keV) the flux increases by a factor of more than two from the minimum at XRISM orbit 40 to the maximum at orbit 55. If we take that into account and repeat our analysis, the predicted EW ratio for interval (c) becomes completely in agreement with the observed ratio and constrains log⁡ξ\log\xi to a value larger than about 3.15. Most of the ionising luminosity in the spectrum of NGC 3783 is in the invisible EUV range, prohibiting a more detailed analysis. However, the above considerations do not alter the derived limits on log⁡ξ\log\xi in a serious way.

Estimating the response timescales of the absorbers

The transmission lags are measured relative to the X-ray continuum peaks because these peaks provide the driving changes in the ionizing radiation field. If the absorber responds through photoionization and recombination, variations in the transmission should follow the continuum changes with a characteristic response time set primarily by the recombination timescale [53] (Li et al. 2023). The delay between the X-ray peak and the subsequent transmission response can be used to constrain the density of the absorbing plasma (Li et al. 2025).

We fitted the data in panels (c) and (d) of Figure 3 locally with a linear baseline plus a Gaussian. This determines tpt_{\mathrm{p}}, the time of the absorption peak or trough in the blue-shaded region following flare C. The 0.3–10 keV light curve in Sect. 3.1 drives the tpho calculations, whereas the 0.3–0.7 and 3–6 keV light curves are used here to determine the continuum-peak time and estimate the absorber-response lag. These narrower bands largely avoid the Fe UTA absorption and Fe K emission complexes, respectively, and therefore provide cleaner continuum tracers. This lag estimate is independent of the tpho modelling. We define the lag as

tlag=tp−tflare,(5)t_{\mathrm{lag}} = t_{\mathrm{p}} - t_{\mathrm{flare}}, \tag*{(5)}

where tflaret_{\mathrm{flare}} is the continuum-peak time in the corresponding energy band. Because neither band represents the full ionising SED and the temporal sampling limits the accuracy of the peak-time measurements, we estimate the lag relative to both the hard- and soft-band peaks (Figure 1) and adopt the larger upper bound as a conservative limit on the absorber response time.

The 3–6 keV hard X-ray flux peaks at orbit 52, the 0.3–0.7 keV soft X-ray flux peaks at orbit 55. The lag could be 5.5±3.55.5 \pm3.5 orbits (hard) or 2.5±3.52.5 \pm3.5 orbits (soft) for interval (c). Hence only an upper limit of ≲9\lesssim9 orbits for interval (c) is realistic. For interval (d), the peak of the response in the blue-shaded region of Figure 3 is poorly constrained to the range of orbits 37–78. The lag could be 5.2±20.65.2 \pm20.6 orbits (hard) or 2.2±20.62.2 \pm20.6 orbits (soft), which enables us to obtain an upper limit on the response time of ∼25.8\sim25.8 orbits, or ∼150\sim150 ks.

Density lower limits from the photoionisation-equilibrium approach

We interpret the measured lag as an upper limit on the charge-state transition time, tCt_{\mathrm{C}}, which describes the finite ionisation/recombination response of the plasma Li et al. (2023). Therefore, tC≤tlagt_{\mathrm{C}} \le t_{\mathrm{lag}}. For velocity intervals (c) and (d), we obtain tC≤tlag≲50, 150t_{\mathrm{C}} \le t_{\mathrm{lag}} \lesssim50,\ 150 ks, respectively. For a given SED, log⁡10(tCne)\log_{10}(t_{\mathrm{C}}n_{\mathrm{e}}) is a function of ionisation parameter and atomic number, which increases slightly with increasing log⁡ξ\log\xi Li et al. (2023). The upper limit on tCt_{\mathrm{C}} therefore gives a lower limit on the electron density.

Using the normal-state 2001 SED and the same energy grid as Li et al. (2023), we obtain a density lower limit for velocity interval (c) of ne≳2.4×1012 m−3n_{\mathrm{e}} \gtrsim2.4 \times10^{12}\ \mathrm{m}^{-3} for log⁡ξ=3.2\log\xi= 3.2, ne≳4.24×1012 m−3n_{\mathrm{e}} \gtrsim4.24 \times10^{12}\ \mathrm{m}^{-3} for log⁡ξ=3.5\log\xi= 3.5. We therefore adopt the conservative lower limit ne≳2.4×1012 m−3n_{\mathrm{e}} \gtrsim2.4 \times10^{12}\ \mathrm{m}^{-3} for interval (c). For interval (d), we assume log⁡ξ=2.95\log\xi= 2.95 and obtain a lower density limit of ne≳1.5×1011 m−3n_{\mathrm{e}} \gtrsim1.5 \times10^{11}\ \mathrm{m}^{-3}. Because no lower limit on log⁡ξ\log\xi is available for interval (d), we cannot derive a more conservative density lower limit. Electron-density limits were converted to hydrogen densities using the adopted ne/nHn_{\mathrm{e}}/n_{\mathrm{H}} ratio (1.2 for highly ionised gas of near-solar composition). These density constraints are summarized in Table 3.

Figure 10 compares the time-averaged XRISM density constraints with the warm-absorber components identified with our current time-resolved spectra analysis and modelling. The upper boundary separates escaping and failed winds. Requiring vout≥vescv_{\mathrm{out}} \ge v_{\mathrm{esc}} gives

nH≤nH,esc=Lionvout44ξ(GMBH)2.(6)n_{\mathrm{H}} \le n_{\mathrm{H,esc}} = \frac{L_{\mathrm{ion}}v_{\mathrm{out}}^{4}}{4\xi(GM_{\mathrm{BH}})^{2}} . \tag*{(6)}

Gas above this boundary has vout<vescv_{\mathrm{out}} < v_{\mathrm{esc}} and is therefore a failed wind. The lower boundary follows from Δr≤r\Delta r \le r and NH≃nHΔrN_{\mathrm{H}} \simeq n_{\mathrm{H}}\Delta r [29, 6]:

nH≥nH,geom=ξNH2Lion.(7)n_{\mathrm{H}} \ge n_{\mathrm{H,geom}} = \frac{\xi N_{\mathrm{H}}^{2}}{L_{\mathrm{ion}}}. \tag*{(7)}

Densities below this boundary would imply Δr>r\Delta r > r and are therefore geometrically forbidden. The dotted lines connect the component-specific limits and serve only as guides to the eye. We find that the highly ionized absorber interval (c) is located within the failed-wind region, while the interval (d) is also a failed wind candidate, although an escaping-wind solution cannot be excluded.

Distances and energetics of the highly ionised Fe XXV absorbers

With the density and ionisation parameter derived for the absorbers in intervals (c) and (d), we can further estimate their distances from the SMBH. We summarize the derived properties of these two highly ionized Fe XXV components in Table 3.

For interval (c), we substitute LionL_{\mathrm{ion}}, log⁡ξ=3.2\log\xi= 3.2, and nH=2.0×1012 m−3n_{\mathrm{H}} = 2.0 \times10^{12}\ \mathrm{m}^{-3} into Eq. (1). Here, the 1–1000 Ryd ionizing luminosity is taken to be Lion=6.4×1036 WL_{\mathrm{ion}} = 6.4 \times10^{36}\ \mathrm{W} from the broad-band continuum modelling of Mehdipour et al. [38]. This yields an upper limit of r<0.05r < 0.05 pc for interval (c). To examine whether this absorber is gravitationally bound, we take MBH=3.0×107 M⊙M_{\mathrm{BH}} = 3.0 \times10^{7}\ M_{\odot} Bentz et al. [3] and r=0.05r = 0.05 pc to calculate the local escape velocity. This gives vesc>2.37×103 km s−1v_{\mathrm{esc}} > 2.37 \times10^{3}\ \mathrm{km}\ \mathrm{s}^{-1}, which is significantly larger than the observed velocity range of −320-320 to

Observed quantities
Velocity interval(c) | (d)
vav^{a} (km s−1^{-1})[−320-320, −680-680] | [−680-680, −1040-1040]
tpbt_{\mathrm{p}}^{b} (orbits)57.5±3.557.5 \pm3.5 | 57.2±20.657.2 \pm20.6
tlagct_{\mathrm{lag}}^{c} (ks)<50< 50 | <150< 150
Predicted quantities
log⁡ξd\log\xi^{d}3.2−3.53.2 - 3.5 | ≤2.95\le2.95
nHen_{\mathrm{H}}^{e} (1011 m−310^{11}\ \mathrm{m}^{-3})>20> 20 | >1.2> 1.2
rfr^{f} (pc)<0.05< 0.05 | <0.25< 0.25
vescgv_{\mathrm{esc}}^{g} (10310^{3} km/s)>2.4> 2.4 | >1.0> 1.0

caption: Parameters of velocity intervals (c) and (d) derived from the absorption line variability.

:::

Notes. a^{a} The kinematic velocity range. b^{b} peak or trough time (orbits). c^{c} lag timescale. d^{d} Estimated log⁡ξ\log\xi from Fig. 4.2.1. e^{e} Lower limit hydrogen density. f^{f} Upper limit distance. g^{g} Lower limit escape velocity.

−680 km s−1-680\ \mathrm{km}\ \mathrm{s}^{-1}. This result suggests that the absorber may therefore be gravitationally bound to the SMBH.

Given log⁡ξ=2.95\log\xi= 2.95 and nH=1.22×1011 m−3n_{\mathrm{H}} = 1.22 \times10^{11}\ \mathrm{m}^{-3} for interval (d), the derived distance upper limit is r<0.25r < 0.25 pc, while the resulting lower limit on local escape velocity is 1.02×103 km s−11.02 \times10^{3}\ \mathrm{km}\ \mathrm{s}^{-1}, comparable with the observed outflow speed and favouring a plausible failed-wind interpretation. However, because no lower bound on log⁡ξ\log\xi is available, an escaping solution cannot be excluded for interval (d) over the full allowed range.

We also estimate the kinetic luminosity of the outflow using

Lkin=12M˙outvout2=12μmpnHr2ΩCVvout3,(8)L_{\mathrm{kin}} = \frac{1}{2}\dot{M}_{\mathrm{out}}v_{\mathrm{out}}^{2} = \frac{1}{2}\mu m_{\mathrm{p}}n_{\mathrm{H}}r^{2}\Omega C_{\mathrm{V}}v_{\mathrm{out}}^{3}, \tag*{(8)}

where M˙out\dot{M}_{\mathrm{out}} is the mass outflow rate, μ\mu is the mean atomic weight per proton (≈1.43\approx1.43), mpm_{\mathrm{p}} is the proton mass, Ω\Omega is the solid angle, CVC_{\mathrm{V}} is the volume filling factor, and rr is the radial distance from the source. Adopting a fiducial solid angle of Ω∼2π\Omega\sim2\pi, and CV∼1C_{\mathrm{V}} \sim1 under the assumption of a homogeneous and volumetrically thick outflow, taking into account the averaged outflowing velocity of ∣vout∣=500|v_{\mathrm{out}}| = 500 and 900 km s−1900\ \mathrm{km}\ \mathrm{s}^{-1} for intervals (c) and (d), respectively, we derive the kinetic luminosities of Lkin=3.8×1033L_{\mathrm{kin}} = 3.8 \times10^{33} and 3.9×1034 W3.9 \times10^{34}\ \mathrm{W}.

Using the bolometric luminosity Lbol=2.1×1037 WL_{\mathrm{bol}} = 2.1 \times10^{37}\ \mathrm{W} from broad-band continuum modelling of Mehdipour et al. [38], corresponding to an Eddington ratio of Lbol/LEdd=0.06L_{\mathrm{bol}}/L_{\mathrm{Edd}} = 0.06, we obtain Lkin/Lbol=0.0002L_{\mathrm{kin}}/L_{\mathrm{bol}} = 0.0002 and 0.00190.0019 for intervals (c) and (d), respectively. Under the adopted values of Ω\Omega, CVC_{\mathrm{V}}, and ξ\xi, these fiducial kinetic powers are too small to provide significant feedback to the host galaxy. The higher-velocity component has a less restrictive distance upper limit of r<0.25r < 0.25 pc; its actual distance relative to interval (c) (r<0.05r < 0.05pc) cannot be determined from the present limits. Using XMM-Newton/PN spectra, Reeves et al. [49] observed significant Fe XXV line variability within 10510^{5} s, with the absorption strength becoming stronger at a relatively high flux level. The <0.1< 0.1-pc constraint of Reeves et al. [49] is consistent with the distance limits derived here.

Possible origins of the observed Fe XXV variability in NGC 3783

The opposite responses following flare C—weaker absorption in interval (c) and stronger absorption in interval (d)—qualitatively support two absorbers lying on opposite sides of the equilibrium Fe xxv ion-fraction peak (Figure 9). Although tpho does not reproduce the full variability amplitude in interval (c), this may reflect uncertainty in the initial equilibrium ionisation state rather than rule out a photoionisation response (Sect. 4.1).

Figure 10. Hydrogen density as a function of ionisation parameter for the X-ray winds. The upper and lower density limits (black dots) for escaping winds are derived from the time-averaged spectrum (Mehdipour et al. [36]). The magenta and blue symbols show the results of the time-resolved analysis of Fe xxv absorption variability in the present work. The lower-ionisation failed wind detected with Chandra in 2001 is indicated by the black arrow (Li et al. 2025).

An alternative explanation is transverse motion of inhomogeneous absorbing gas across the line of sight ([27, 8]). Considering the possible transverse motion of the Fe xxv outflow across an X-ray emitting region of ≤20Rg\le20 R_{\mathrm{g}} ([51]), the crossing time is defined as (Li et al. 2023)

tcross=20c2(G×MBH)1/2(L⊙ξ⊙)1/4nH−1/4,(9)t_{\mathrm{cross}} = \frac{20}{c^2}(G \times M_{\mathrm{BH}})^{1/2}\left(\frac{L_{\odot}}{\xi_{\odot}}\right)^{1/4}n_{\mathrm{H}}^{-1/4}, \tag*{(9)}

where L⊙=6.36×1036 WL_{\odot} = 6.36 \times10^{36}\ \mathrm{W} (Mehdipour et al. [38]) and ξ⊙\xi_{\odot} is the adopted ionisation parameter of the corresponding absorber. At the density lower limits, we obtain tcross≲5.3×105t_{\mathrm{cross}} \lesssim5.3 \times10^{5} and ≲1.23×106 s\lesssim1.23 \times10^{6}\ \mathrm{s} for intervals (c) and (d), respectively. These timescales are approximately 11 and 8 times longer than the corresponding response-time upper limits of 50 and 150 ks.

Changes in the geometry or surface-brightness distribution of the X-ray corona could also alter the effective sight lines through an inhomogeneous absorber, producing apparent changes in absorption depth ([63, 52, 17]). The newly detected relativistic Fe fluorescence line may provide additional constraints on the disc–corona geometry (Li et al. 2026). Local density fluctuations provide another possible explanation ([62, 42]). However, neither scenario naturally explains the opposite line responses associated with flare C.

C. Longer XRISM observations with multiple flares and simultaneous broadband coverage are needed to distinguish these scenarios from photoionisation-driven variability.

Summary

We present a time-resolved analysis of the Fe xxv absorption line observed during the 10-day XRISM/Resolve campaign of NGC 3783. Three velocity intervals exhibit significant equivalent-width (EW) variability. Intervals (c) and (d) respond differently between the low- and high-flux states, indicating temporal changes in the physical absorber components. However, direct time-dependent photoionisation modelling of the lower-velocity component with tpho cannot reproduce the strongest EW variation. This is likely because the initial equilibrium solution derived from the time-averaged spectrum is not unique. As a result, we are unable to obtain a precise density constraint for this component.

Using photoionisation calculations (pion) based on the 2001 unobscured SED and assuming the high-density limit, we estimate the ionisation-parameter ranges of these two velocity components. The lower-velocity component, at −320-320 to −680 km s−1-680\ \mathrm{km\ s^{-1}} with log⁡ξ∼3.2−3.5\log\xi\sim3.2 - 3.5, shows an inverse response to the continuum with a response-time upper limit of ∼50\sim50 ks, implying a density of ne>2.38×1012 m−3n_{\mathrm{e}} > 2.38 \times10^{12}\ \mathrm{m^{-3}} and a distance of <0.05< 0.05 pc. The higher-velocity component, at −680-680 to −1040 km s−1-1040\ \mathrm{km\ s^{-1}} with log⁡ξ≲2.95\log\xi\lesssim2.95, shows a positive response with a lag upper limit of approximately 150 ks. This implies a density lower limit of ne>1.46×1011 m−3n_{\mathrm{e}} > 1.46 \times10^{11}\ \mathrm{m^{-3}}, and a distance upper limit of r<0.25r < 0.25 pc. The absorber associated with interval (c) is a failed-wind candidate because its outflow velocity is below the local escape velocity. The higher-velocity interval (d) may lie near the failed wind threshold. Together with the failed Fe UTA wind identified in 2001, these results suggest that NGC 3783 hosts a multiphase failed-wind structure in its unobscured state.

Acknowledgements

C.L. acknowledges support from the Chinese Scholarship Council (CSC) and Leiden University/Leiden Observatory, as well as SRON. SRON is supported financially by NWO, the Netherlands Organization for Scientific Research. M. Mehdipour acknowledges support from the NASA XRISM Guest Scientist (XGS) grant (80NSSC23K0995). S. Ogawa acknowledges JSPS KAKENHI grant No. 24K17104.

References

  1. [1]Behar, E., Rasmussen, A. P., Blustin, A. J., et al. 2003, ApJ, 598, 232
  2. [2]Behar, E., Sako, M., & Kahn, S. M. 2001, ApJ, 563, 497
  3. [3]Bentz, M. C., Street, R., Onken, C. A., & Valluri, M. 2021, ApJ, 906, 50
  4. [4]Bianchi, S. & Matt, G. 2002, A&A, 387, 76
  5. [5]Bianchi, S., Matt, G., Nicastro, F., Porquet, D., & Dubau, J. 2005, MNRAS, 357, 599
  6. [6]Blustin, A. J., Page, M. J., Fuerst, S. V., Branduardi-Raymont, G., & Ashton, C. E. 2005, A&A, 431, 111
  7. [7]Brenneman, L. W., Wilkins, D. R., Ogorzalek, A., et al. 2025, ApJ, 995, 200
  8. [8]Crenshaw, D. M., Kraemer, S. B., Gabel, J. R., et al. 2003, ApJ, 594, 116
  9. [9]Fukumura, K., Kazanas, D., Contopoulos, I., & Behar, E. 2010, ApJ, 715, 636
  10. [10]Fukumura, K., Kazanas, D., Shrader, C., et al. 2018, ApJ, 853, 40
  11. [11]Fukumura, K., Mehdipour, M., Behar, E., et al. 2024, ApJ, 968, 70
  12. [12]Gaspari, M. & Sądowski, A. 2017, ApJ, 837, 149
  13. [13]Giustini, M. & Proga, D. 2019, A&A, 630, A94
  14. [14]Giustini, M. & Proga, D. 2021, in IAU Symposium, Vol. 356, Nuclear Activity in Galaxies Across Cosmic Time, ed. M. Pović, P. Marziani, J. Masegosa, H. Netzer, S. H. Negu, & S. B. Tessema, 82–86
  15. [15]Gofford, J., Reeves, J. N., McLaughlin, D. E., et al. 2015, MNRAS, 451, 4169
  16. [17]Jiang, J., Gallo, L. C., Gruppe, D., & Parker, M. L. 2022, MNRAS, 516, 4256
  17. [18]Juraňová, A., Kara, E., Behar, E., et al. 2026, The Astrophysical Journal, 1005, 27
  18. [19]Kaastra, J. S., Detmers, R. G., Mehdipour, M., et al. 2012, A&A, 539, A117
  19. [20]Kaastra, J. S., Mewe, R., & Nieuwenhuijzen, H. 1996, in UV and X-ray Spectroscopy of Astrophysical and Laboratory Plasmas, ed. K. Yamashita & T. Watanabe, 411–414
  20. [21]Kaastra, J. S., Rassen, A. J., de Plaa, J., & Gu, L. 2024, SPEX X-ray spectral fitting package (3.08.01). Zenodo.
  21. [22]Kaastra, J. S., Steenbrugge, K. C., Raassen, A. J. J., et al. 2002, A&A, 386, 427
  22. [23]Kaspi, S., Brandt, W. N., George, I. M., et al. 2002, ApJ, 574, 643
  23. [24]Kaspi, S., Brandt, W. N., Netzer, H., et al. 2001, ApJ, 554, 216
  24. [25]Kayanoki, T., Fukazawa, Y., Mao, J., et al. 2026, The Astrophysical Journal, 1002, 91
  25. [26]Kelley, R. L., Ishisaki, Y., Costantini, E., et al. 2025, Journal of Astronomical Telescopes, Instruments, and Systems, 11, 042026
  26. [27]Kraemer, S. B., Crenshaw, D. M., Hutchings, J. B., et al. 2001, ApJ, 551, 671
  27. [28]Krolik, J. H. & Kriss, G. A. 1995, ApJ, 447, 512
  28. [29]Krolik, J. H. & Kriss, G. A. 2001, ApJ, 561, 684
  29. [30]Krongold, Y., Nicastro, F., Brickhouse, N. S., et al. 2003, ApJ, 597, 832
  30. [31]Laha, S., Reynolds, C. S., Reeves, J., et al. 2021, Nature Astronomy, 5, 13
  31. [35]Mao, J., Mehdipour, M., Kaastra, J. S., et al. 2019, A&A, 621, A99
  32. [36]Mehdipour, M., Kaastra, J. S., Eckart, M. E., et al. 2025, A&A, 699, A228
  33. [37]Mehdipour, M., Kaastra, J. S., & Kallman, T. 2016, A&A, 596, A65
  34. [38]Mehdipour, M., Kaastra, J. S., Kriss, G. A., et al. 2017, A&A, 607, A28
  35. [39]Mehdipour, M., Miller, J. M., Kaastra, J. S., et al. 2026, ApJ, 1008, 56
  36. [40]Miller, J. M., Xiang, X., Byun, D., et al. 2025, ApJ, 994, L10
  37. [41]Miller, J. M., Xiang, X., Mehdipour, M., et al. 2026, The Astrophysical Journal Letters, 1003, L34
  38. [42]Mizumoto, M., Done, C., Tomaru, R., & Edwards, I. 2019, MNRAS, 489, 1152
  39. [43]Mizumoto, M., Nomura, M., Done, C., Oshuga, K., & Odaka, H. 2021, MNRAS, 503, 1442
  40. [44]Mizumoto, M., Reeves, J. N., Braito, V., et al. 2026, ApJ, 997, 219
  41. [45]Netzer, H., Kaspi, S., Behar, E., et al. 2003, ApJ, 599, 933
  42. [46]Nicastro, F., Fiore, F., Perola, G. C., & Elvis, M. 1999, ApJ, 512, 184
  43. [47]Noda, H., Yamada, S., Ogawa, S., et al. 2025, ApJ, 993, L53
  44. [48]Owen, J. E. & Lin, D. N. C. 2025, MNRAS, 544, 4532
  45. [49]Reeves, J. N., Nandra, K., George, I. M., et al. 2004, ApJ, 602, 648
  46. [50]Reeves, J. N., Ogawa, S., Turner, T. J., et al. 2026, ApJ, 1001, 137
  47. [51]Reis, R. C. & Miller, J. M. 2013, ApJ, 769, L7
  48. [52]Risaliti, G., Salvati, M., Elvis, M., et al. 2009, MNRAS, 393, L1
  49. [53]Rogantini, D., Mehdipour, M., Kaastra, J., et al. 2022, ApJ, 940, 122
  50. [54]Sadaula, D. R., Bautista, M. A., García, J. A., & Kallman, T. R. 2023, ApJ, 946, 93
  51. [55]Sadaula, D. R., Kallman, T. R., & Laha, S. 2025, ApJ, 992, 182
  52. [56]Takeuchi, S., Ohsuga, K., & Mineshige, S. 2013, PASJ, 65, 88
  53. [57]Tarter, C. B., Tucker, W. H., & Salpeter, E. E. 1969, ApJ, 156, 943
  54. [58]Tashiro, M., Kelley, R., Watanabe, S., et al. 2025, PASJ, 77, S1
  55. [59]Tombesi, F., Cappi, M., Reeves, J. N., et al. 2013, MNRAS, 430, 1102
  56. [60]Tombesi, F., Sambruna, R. M., Reeves, J. N., et al. 2010, ApJ, 719, 700
  57. [61]Vardi, G., Behar, E., Gu, L., et al. 2026, ApJ, 1007, L23
  58. [62]Waters, T., Proga, D., Dannen, R., & Kallman, T. R. 2017, MNRAS, 467, 3160
  59. [63]Wilkins, D. R. & Gallo, L. C. 2015, MNRAS, 449, 129
  60. [64]Xiang, X., Miller, J. M., Behar, E., et al. 2025, ApJ, 988, L54
  61. [68]Yamada, S., Kawamuro, T., Mizumoto, M., et al. 2024, ApJS, 274, 8
  62. [69]Zaidouni, F., Kara, E., Kosec, P., et al. 2026, ApJ, 997, L26
  63. [70]Zhao, K., Kaastra, J. S., Gu, L., et al. 2026, A&A, 710, A192

Paper details

vlnc:W_v5xukd26
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 0

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents