WorksPhysics and Astronomy
Single-shot on-chip measurement of the modal Stokes parameters
Abstract
Integrated photonics has recently facilitated manipulating multimode partially coherent light in a compact mesh of Mach-Zehnder interferometers. A critical task in this context is on-chip reconstruction of the coherence matrix through a sequence of measurement configurations, thus giving rise to a speed bottleneck stemming from temporal delays in tuning on-chip phase shifts. Here we demonstrate single-shot reconstruction of the coherence matrix for two-mode partially coherent light by parallelizing the on-chip measurements of the modal Stokes parameters, thereby exchanging space for time. Although a larger chip area is required, the reconstruction is limited only by detection speed, thus potentially paving the way to real-time reconstruction of coherence matrices for applications in high-speed communications, cryptography, computation, and sensing.
Rapid reconstruction of an unknown, finite-dimensional coherence matrix has recently become essential to fully exploit the ‘coherence advantage’: optical information processing configurations in which partially coherent light outperforms coherent light. Examples include increasing the communications capacity over an -mode channel (e.g., spatial-mode multiplexing in a multimode fiber [1]), where partially coherent light provides independent communication channels in lieu of for coherent light [2]. Another example is coherence-rank optical communications across a rapidly varying, strongly scattering channel [3], where the rank of the coherence matrix (the number of its non-zero eigenvalues [4, 5]) is a scattering-immune information carrier. Both applications, among other recent examples of optical information processing that also benefit from partially coherent light in computation [6], cryptography [7], number factoring [8], and sensing [9], requiring rapid reconstruction of a coherence matrix as a fundamental building block.
To date, two strategies have been utilized to reconstruct in on-chip programmable photonics platforms [10, 11]. One approach tomographically reconstructs by first measuring the modal Stokes parameters (SPs) [12, 13, 14, 15, 16], a generalization of the usual polarization SPs [17, 18] to other degrees-of-freedom of the field (e.g., spatial modes). This strategy sequentially implements a fixed number of measurement settings, realized recently in an on-chip hexagonal mesh of Mach-Zehnder interferometers (MZIs) with two-mode [19] and four-mode [20] partially coherent light. Alternatively, in ‘variational processing’ pairs of modes traverse a unitary transformation (‘unitary’ for brevity) whose parameters are scanned to reconstruct [21]. The speed bottleneck remains the temporal delay encountered when tuning on-chip phase shifters at each step of the measurement sequence, which sets an ultimate limit on the reconstruction speed of .
Here we demonstrate single-shot on-chip reconstruction of the coherence matrix of two-mode partially coherent light using the tomographic reconstruction approach after acquiring the modal SPs. In contrast to recent experiments [19, 20], we exchange space for time to parallelize the measurements – rather than sequentially implementing them in a smaller occupied space but with added temporal delays. On-chip detectors acquire the modal weights to estimate the modal SPs and reconstruct in a single shot. We confirm that the fidelity of single-shot reconstruction is comparable to that of its sequential counterpart, and we reconstruct an arbitrary at a rate limited by only the detector speed. The two-mode single-shot measurement configuration is the building block for larger-dimensional coherence matrices. Our results therefore open a path to real-time, high-speed on-chip reconstruction of the coherence matrix for optical communications and information processing applications.
Consider an optical field spanned by two modes labeled and in the Dirac notation, which correspond here to the fields in two single-mode on-chip waveguides. The coherence matrix for this field in terms of the modal SPs is:
where , , and are the field amplitudes in the two waveguides, , we normalize to unity trace , and are the modal weights (the fractions of power in each mode), the real expansion coefficients are the modal SPs, are the usual Pauli matrices:
and is the identity matrix. We obtain the modal SPs via , so that , , , , from which is reconstructed (Eq. (1)). SPs are well known in polarization optics [18] but are equally applicable to any bimodal field [22, 23].
To measure , we implement a sequence of three settings [Fig. 1(a)], each involving a unitary after which the modal weights and are measured, whereupon ; here, corresponding to a direct measurement of the modal weights, , and . We normalize the SPs with respect to . Substituting the acquired modal SPs into Eq. (1) reconstructs . We refer to this procedure as a ‘sequential measurement’ of the modal SPs. The need to cycle through three unitaries, followed each time with a measurement, indicates that the reconstruction speed is limited by both the on-chip phase shifters and detectors.
In the proposed single-shot approach [Figure 1(b)], the unitaries are laid out in space concurrently. After each unitary, a portion of the power is diverted by symmetric couplers (50 : 50 split) to detectors. We first record and , from which we obtain and ; after the detected modal weights and yield ; and after , which undoes before implementing , the detected modal weights and yield . The obtained modal SPs are substituted into Eq. (1) to reconstruct . In this configuration we exchange space for time, the phase-shifters in the unitaries remain static, and the detectors record the measurements simultaneously. Consequently, the measurement speed is limited solely by the detectors. This distinction provides the potential for continuous reconstruction of a temporally varying .

Figure 1. (a) Configurations for the sequential acquisition of the modal SPs: and using a unitary ; with ; and with [19]. (b) Schematic for the proposed single-shot measurement of the modal SPs.
We carry out our experiments using the setup in Figure 2(a). A laser diode at a wavelength is coupled to a single-mode fiber (SMF), split into two paths using a 3-dB fiber coupler, and a fiber loop of length (exceeding the laser coherence length) is placed in one of the paths. Attenuators and polarization controllers yield equal amplitudes and optimally match the polarization to the on-chip waveguides. To confirm that the SMF fields are mutually incoherent, we

Figure 2. (a) Optical setup. A: Attenuator; PC: polarization controller; FL: fiber loop; M: modulator. Three tasks are performed on chip: adjusting the eigenvalues and , changing the basis of via the unitary , followed by a measurement of the modal SPs. (b) Setup for recording free-space interference between the two modes. C: Fiber collimator; BS: balanced beam splitter. (c) Intensity profile in absence and presence of the fiber loop in (b), where interference fringes appear or disappear, respectively. (d) Layout of the on-chip MZI mesh for sequential and (e) single-shot measurement of the modal SPs. BD: Beam dump. Each gray rectangle is an MZI and the lines are single-mode on-chip waveguides.
out-couple the fields to free space via fiber collimators, superpose the fields at a balanced beam splitter, and record the intensity distribution with a camera (Bobcat-320-GigE-13907, Xenics) [Figure 2(b)]. In absence of the fiber loop, the two fields are mutually coherent and interference fringes are observed; while in presence of the fiber loop, the fields are mutually incoherent, and the fringes are eliminated [Figure 2(c)]. Because the two modal weights are equal and the modes are mutually incoherent, the prepared coherence matrix is . Once coupled to the chip, we first tune the relative modal weights to and , with . A unitary then converts this diagonal coherence matrix to any form desired, , while maintaining its degree of coherence . The degree of coherence is not simply the observable interference visibility when superposing the two modes, but corresponds to the maximum visibility observable after equalizing the modal amplitudes [22, 24]; see an experimental demonstration of this concept using on-chip generated two-mode fields in Ref. [19]. Finally, the coherence matrix is reconstructed on chip via a measurement of the modal SPs – utilizing both the sequential and single-shot approaches.
The integrated photonic chip (iPronics Smartlight Processor) is a hexagonal mesh of 72 MZIs, each formed of two phase shifts and for modes and , respectively, sandwiched between symmetric couplers, yielding the unitary
where and [19, 20]. By sandwiching an MZI between relative phase shifters by and between the modes, we obtain a general unitary
[19, 20]. The chip layouts for the sequential and single-shot schemes are illustrated in Figure 2(d,Figure 2e). In the former, the unitary cycles between three selections: to obtain , to obtain , and to obtain . The measurements are acquired at three instances in time following the change in the unitary. In the single-shot realization, unitaries and are cascaded. Portions of the modes are first diverted to yield and , and after to yield and . Measurements after yield and . The six outputs and , , are recorded simultaneously (single-shot).
We first validate the performance of the single-shot measurement of modal SPs with respect to its sequential counterpart. For this measurement we do not make use of the external modulator, and start from the coherence matrix
coupled to the chip, adjust the eigenvalues and , and then rotate the basis via a unitary . We implemented 5 coherence matrices (G₁ through G₅) and reconstructed them using the sequential and single-shot approaches. We plot in Figure 3 the reconstructed coherence matrices via the two approaches, separating the real and imaginary parts, Re{G} and Im{G}, respectively. We make use of the fidelity

Figure 3. On-chip reconstruction of the coherence matrix G via measurements of the modal SPs. The columns correspond to the coherence matrices G₁ through G₅ given in the top row. (a) Reconstructing G via on-chip (a) sequential and (b) single-shot measurements. We plot Re{G} and Im{G} separately. The color map is modified to accentuate even minor differences.
as a measure of the reconstruction quality [25], where Gₜₕ and Gₘ are the theoretical and reconstructed coherence matrices, respectively. The sequential reconstruction has and the single-shot counterpart has .
To ensure that the single-shot approach is capable of reconstructing any coherence matrix, we select three values of ( and ) and then sweep the two parameters in the unitary placed in the path of the modes Figure 2(a,Figure 2d,Figure 2e): the relative phase and coupling ratio introduced between the two modes. This enables spanning the entire surface of the Poincaré sphere Figure 4, thereby confirming that there are no ‘blind spots’ in this detection scheme. The data plotted in Figure 4 indicates that the single-shot approach can reconstruct G at any point on the Poincaré sphere (coherent fields) or within its volume (partially coherent fields).

Figure 4. Single-shot reconstruction of G. We plot each reconstructed field as a point on the surface of the Poincaré sphere of radius and axes , for (coherent fields), , and .
Finally, to ascertain the gain in processing speed, we employ an external amplitude modulator (Uniphase) in one input path preceding the chip [M in Fig. 2(a) ]. An electrical signal in the form of a sinusoid of frequency from a waveform generator with an appropriate electrical bias is sent to the modulator to produce the diagonal coherence matrix
where is the modulated optical power. The eigenvalues are and , so that the degree of coherence is . We first set the on-chip unitary to , so the coherence matrix to be reconstructed is . In this case, the modal SPs are and , so that . We carry out single-shot reconstruction of , from which we extract [Figure 5(a-Figure 5c)]. We vary from 0.1 Hz to 100 Hz, and the on-chip detectors sample the field every 4 ms (the on-chip detector limit). In the sequential approach, the limit on the speed of reconstructing is dominated by the speed of on-chip thermal phase-shift change (it is expected that electro-optic phase shifters will be faster). Reconstruction even at Hz could not be achieved by the sequential approach. We plot in Figure 5(a-Figure 5c) the measured using the single-shot approach for , 50, and 100 Hz. This approach continues to reconstruct to at least Hz.

Figure 5. Real-time reconstruction of the coherence matrix via single-shot measurement of the modal SPs. (a-c) obtained from the reconstructed diagonal coherence matrix : (a) Hz, (b) 50 Hz, and (c) 100 Hz. (d) obtained from the non-diagonal reconstructed at Hz. (e) The acquired individual modal SPs , , and from which we obtain as plotted in (d). Data points are spaced 4 ms apart (the on-chip detector speed limit).
Next, we set and in to render all the SPs non-zero without changing the degree of coherence . We plot for Hz in Figure 5(d). The expected SPs are , , and , which are in excellent agreement with the measured SPs [Figure 5(e)]. These results indicate that the single-shot approach allows for real-time reconstruction of by first acquiring the SPs.
We have realized single-shot on-chip measurements of the modal SPs cascaded in space rather than sequenced in time. Other spatial configurations can be pursued that may require fewer MZIs in their construction. The integrated photonic circuit used in our experiments is a general purpose programmable mesh of MZIs, and its topology is not optimized for the particular task at hand. More efficient chip-level layouts can thus further compactify the device size, which will be essential for scaling up the single-shot approach to modes [20].
The single-shot approach alleviates the speed bottleneck arising from on-chip phase shifters, leaving only the detector speed to limit the reconstruction rate. Using high-speed detectors, whether external or on-chip, we can readily exceed a MHz reconstruction rate. Using the reversible conversion between spatial and polarization modes demonstrated in [26, 27, 28, 29], we expect integrated photonic systems to enable compact, MHz-rate Stokes polarimetry, which may open new pathways in metrology, biosensing, and molecular control [30, 31, 32].
In conclusion, we have demonstrated a scheme for single-shot measurements of the modal SPs implemented in an integrated photonic circuit to reconstruct the coherence matrix for two-mode partially coherent light. Rather than sequentially reconfiguring the on-chip circuit serially in time, we instead parallelize the requisite configurations in space to acquire the SPs in a single shot. The on-chip layout is thus static, thereby swapping time for space, or sacrificing the size of the device for higher-speed reconstruction of the coherence matrix – limited only by the detector speed. These results may help the development of high-speed Stokes polarimetry, in addition to further increasing the speed of on-chip processing of partially coherent light in optical communications, computation, and spectroscopy.
Acknowledgments: We thank G. Li and D. Hudson for loan of equipment and Saikat Saha for connectorizing fibers.
Funding: U.S. Office of Naval Research (ONR) N00014-20-1-2789.
References
- [1]G. Li, N. Bai, N. Zhao, and C. Xia, Space-division multiplexing: the next frontier in optical communication, Adv. Opt. Photon. 6, 413 (2014).DOI
- [2]A. Nardi, S. Divitt, M. Rossi, F. Tebbenjohanns, A. Militaru, M. Frimmer, and L. Novotny, Encoding information in the mutual coherence of spatially separated light beams, Opt. Lett. 47, 4588 (2022).
- [3]M. Harling, C. Stevenson, K. C. Toussaint, and A. F. Abouraddy, Optical communications through highly scattering channels using the coherence-rank, APL Photonics 10, 076116 (2025).
- [4]M. Harling, V. A. Kelkar, K. C. Toussaint, and A. F. Abouraddy, Locked entropy in partially coherent optical fields, Phys. Rev. A 109, L021501 (2024).DOI
- [5]M. Harling, V. A. Kelkar, K. C. Toussaint, and A. F. Abouraddy, Isoentropic partially coherent optical fields that cannot be interconverted unitarily, Phys. Rev. A 110, 013505 (2024).DOI
- [6]B. Dong, F. Brückerhoff-Plückelmann, L. Meyer, J. Dijkstra, I. Bente, D. Wendland, A. Varri, S. Aggarwal, N. Farmakidis, M. Wang, G. Yang, J. S. Lee, Y. He, E. Gooskens, D.-L. Kwong, P. Bienstman, W. H. P. Pernice, and H. Bhaskaran, Partial coherence enhances parallelized photonic computing, Nature 632, 55 (2024).DOI
- [7]X. Liu, X. Li, S. A. Ponomarenko, F. Wang, X. Peng, Y. Cai, and C. Liang, Unlocking secure optical multiplexing with spatially incoherent light, Laser Photon. Rev. 19, 2401534 (2025).DOI
- [8]X. Liu, C. Liang, Y. Cai, and S. A. Ponomarenko, Axial correlation revivals and number factorization with structured random waves, Phys. Rev. Appl. 20, L021004 (2023).DOI
- [9]J. S. Tyo, D. L. Goldstein, D. B. Chenault, and J. A. Shaw, Review of passive imaging polarimetry for remote sensing applications, Appl. Opt. 45, 5453 (2006).pubmed.ncbi.nlm.nih.gov/16855644
- [10]J. Campany and D. Pérez, Programmable Integrated Photonics (Oxford Univ. Press, Oxford, 2020).
- [11]W. Bogaerts, D. Pérez, J. Capmany, D. A. B. Miller, J. Poon, D. Englund, F. Morichetti, and A. Melloni, Programmable photonic circuits, Nature 586, 207–216 (2020).
- [12]D. F. V. James, P. G. Kwiat, W. J. Munro, and A. G. White, Measurement of qubits, Phys. Rev. A 64, 052312 (2001).DOI
- [13]A. F. Abouraddy, A. V. Sergienko, B. E. A. Saleh, and M. C. Teich, Quantum entanglement and the two-photon Stokes parameters, Opt. Commun. 210, 93 (2002).DOI
- [14]K. H. Kagalwala, G. Di Giuseppe, A. F. Abouraddy, and B. E. A. Saleh, Bell’s measure in classical optical coherence, Nat. Photon. 7, 72 (2013).DOI
- [15]A. F. Abouraddy, K. H. Kagalwala, and B. E. A. Saleh, Two-point optical coherence matrix tomography, Opt. Lett. 39, 2411 (2014).DOI
- [16]K. H. Kagalwala, H. E. Kondakci, A. F. Abouraddy, and B. E. A. Saleh, Optical coherency matrix tomography, Sci. Rep. 5, 15333 (2015).DOI
- [17]C. Brosseau and A. Dogariu, Symmetry properties and polarization descriptors for an arbitrary electromagnetic wavefield, Prog. Opt. 49, 315 (2006).DOI
- [18]E. Wolf, Introduction to the Theory of Coherence and Polarization of Light (Cambridge Univ. Press, Cambridge, 2007).
- [19]A. Hashemi, A. Shiri, B. E. A. Saleh, A. Blanco-Redondo, and A. F. Abouraddy, Programmable on-chip synthesis and reconstruction of partially coherent two-mode optical fields, arXiv:2601.09802 (2026).arxiv.org/abs/2601.09802
- [20]A. Hashemi, A. Shiri, B. E. A. Saleh, A. Blanco-Redondo, and A. F. Abouraddy, On-chip control of the coherence matrix of four-mode partially coherent light: rank, entropy, and modal stokes parameters, arXiv:2601.18797 (2026).arxiv.org/abs/2601.18797
- [21]C. Roques-Carmes, S. Fan, and D. Miller, Measuring, processing, and generating partially coherent light with self-configuring optics, Light Sci. Appl. 13, 260 (2024).
- [22]A. F. Abouraddy, A. Dogariu, and B. E. A. Saleh, Comment on ‘polarization coherence theorem’, Optica 6, 829 (2019).
- [23]A. Halder, A. Norrman, and A. T. Friberg, Poincaré sphere representation of scalar two-beam interference under spatial unitary transformations, Opt. Lett. 46, 5619 (2021).DOI
- [24]F. Zernicke, The concept of the degree of coherence and its application to optical problems, Physica 5, 785 (1938).
- [25]R. Jozsa, Fidelity for mixed quantum states, J. Mod. Opt. 41, 2315 (1994).
- [26]A. F. Abouraddy, What is the maximum attainable visibility by a partially coherent electromagnetic field in Young’s double-slit interference?, Opt. Express 25, 18320 (2017).DOI
- [27]C. Okoro, H. E. Kondakci, A. F. Abouraddy, and K. C. Toussaint, Demonstration of an optical-coherence converter, Optica 4, 1052 (2017).DOI
- [28]M. Harling, V. Kelkar, C. Okoro, M. Diouf, A. F. Abouraddy, and K. C. Toussaint, Reversible inter-degree-of-freedom optical-coherence conversion via entropy swapping, Opt. Express 30, 29584 (2022).DOI
- [29]M. Harling, V. Kelkar, A. F. Abouraddy, and K. C. Toussaint, Reversible coherence conversion across optical degrees-of-freedom: a tutorial, J. Opt. 25, 053502 (2023).DOI
- [30]C. Constant, A. Bergano, K. Sugaya, and A. Dogariu, Guiding cellular activity with polarized light, J. Biophoton. 11, e201600326 (2018).DOI
- [31]J. C. Ramella-Roman, I. Saytashev, and M. Piccini, A review of polarization-based imaging technologies for clinical and preclinical applications, J. Opt. 22, 123001 (2020).
- [32]C. He, H. He, J. Chang, B. Chen, H. Ma, and M. J. Booth, Polarisation optics for biomedical and clinical applications: a review, Light Sci. Appl. 10, 194 (2021).arxiv.org/abs/2108.04571