Atomic magnetometry is one of the most sensitive field-measurement techniques for biological, geo-surveying, and navigation applications. An essential process in atomic magnetometry is measurement of optical polarization rotation of a near-resonant beam due to its interaction with atomic spins under an external magnetic field. In this work, we present the design and analysis of a silicon-metasurface-based polarization beam splitter that have been tailored for operation in a rubidium magnetometer. The metasurface polarization beam splitter operates at a wavelength of 795 nm and has a transmission efficiency > 83% and a polarization extinction ratio > 20 dB. We show that these performance specifications are compatible with magnetometer operation in miniaturized vapor cells with subpicotesla-level sensitivity and discuss the prospect of realizing compact, high-sensitivity atomic magnetometers with nanophotonic component integration.

MetasurfaceForBalancedPolarimetry v22

Introduction

Atomic magnetometers based on optical pumping can provide sub-femtotesla-level sensitivity [1] and are therefore attractive for a host of magnetometry applications including biological sensing [2, 3], geo-surveying [4], and magnetic map-based navigation [4, 5]. Optically pumped magnetometers (OPMs) typically involve optical pumping of alkali atoms (most commonly rubidium or cesium) with a circularly polarized beam to modify the atomic-spin-dependent optical properties of a medium inside a vapor cell. A linearly polarized probe beam is then used to detect the precession of the atomic spin in the presence of a magnetic field [6]. Typically, this precession causes a polarization rotation of the probe beam which is detected with an optical polarimeter involving a balanced polarimetry, photoelastic or Faraday modulation method [7]. Most OPMs have been realized using an orthogonal pump-probe arrangement with balanced optical polarimetry, since it has a simple configuration and if sufficiently balanced, can suppress common-mode noise arising from laser intensity fluctuations [8].

While breakthroughs in microfabricated vapor cells [9] have enabled the miniaturization of OPMs and their integration with chip-scale photonic technologies such as VCSELs [2, 10], state-of-the-art OPMs based on balanced polarimetry detection mostly utilize bulk birefringent polarization optics such as waveplates and polarizing beam splitters which still limit the sensor volume, scalability, and their use in many portable applications [11, 12, 13]. More recently, various schemes have been proposed [14, 15] and experimentally demonstrated [16, 17] to further integrate OPMs with nanophotonic components, but the performance limits of nanophotonic-integrated OPMs are still being explored.

A common approach to simplify OPM designs and make them more scalable towards realizing multi-channel OPM arrays is to have the pump and probe beams share a single optical axis. These inline OPM schemes can be achieved by using a single elliptically polarized beam [18] or by overlapping the pump and probe beams at different transitions (e.g., the D1 and D2 lines) [19]. Inline OPM configurations are also highly compatible with miniaturized magnetometers since microfabricated vapor cells usually allow only one optical access path.

In this work, we propose integration of inline OPMs with metasurface-based polarization components (Figure 1). Specifically, we have designed an efficient and compact balanced polarimetry scheme using a metasurface-based polarization beam splitter (PBS). The geometry of our metasurface-based PBS can be freely optimized and tailored for integration with other atomic species and single-beam OPM designs. In addition, with advances in MEMS vapor cell fabrication [20] as well as techniques to integrate atomic vapor with integrated photonic circuits [16, 17, 21, 22, 23], it should be possible to directly fabricate metasurfaces on the glass windows of atomic-vapor cells.

Schematic of the proposed atomic magnetometer with a metasurface-based polarimeter

Figure 1. Schematic of the proposed atomic magnetometer with a metasurface-based polarimeter. LP: linear polarizer; QWP: quarter waveplate; PD: photodetector.

We then evaluate the accuracy and sensitivity of atomic magnetometry using the miniaturized balanced detection scheme. For our OPM platform, we use Spin Exchange Relaxation Free (SERF) magnetometry in rubidium (Rb) with elliptically polarized light [16]. SERF magnetometers typically operates in a high atomic density regime (>1013 cm−3>10^{13}\ \mathrm{cm}^{-3}) where the spin-exchange collision rate of the alkali metal atoms is much larger than the Larmor precession frequency, resulting in longer ground state Zeeman coherence time and thus extremely high sensitivity [18]. In this case, the circularly polarized component of the elliptically polarized light induces atomic polarization in the ground state of isotopically purified Rb atoms through optical pumping. A balanced polarimetry scheme is then used to measure the optical rotation of the linearly polarized component of the transmitted light at the output of the cell. The balanced polarimeter consists of a

metasurface PBS that splits the horizontal and vertical linear polarization components of the light beam propagating through the vapor cell medium which are then measured using two independent photodetectors. The detection of the difference of the horizontal and vertical linear polarization intensities provides a direct measure of the optical rotation. The sensitivity of the magnetometer is determined by the signal-to-noise ratio with which the rotation signal is measured.

The paper is structured as follows. In section 2, we introduce our approach to design nanophotonic components for miniaturized balanced detection scheme in in-line OPMs. Optical performance of those components is discussed including transmission losses and polarization extinction ratio. A performance analysis of SERF with metasurface optics is presented in section 3.

Design and modeling of metasurface-based PBS

Design approach

Recently, dielectric metasurfaces made of arrays of elliptical posts have been adopted to design a wide range of nanophotonic components (such as beam splitters, waveplates and optical lenses) offering efficient control of the amplitude, phase, and polarization of light. The majority efforts have been dedicated to engineer metalenses [25], beam shaping devices [26, 27], polarization optics [28] and holograms [29]. These advances have recently been applied to trap and cool atoms on a chip [30]. In this paper, we adapt an approach to design metasurface polarization components for operation at near-infrared (780 - 795 nm) wavelengths and thus compatible with Rb-based sensors. Our designs maintain high-transmission efficiency and polarization extinction ratio. Our approach is based on the formalism described by Arbabi et al in [28]. Specifically, we implement metasurface optical components by arrays of elliptical posts with the same height, but different diameters to locally modify the phase distribution and polarization of any arbitrary input beam.

We consider a transmissive metasurface polarizing beam splitter design (Figure 2a) that can be used in a variety of miniaturized OPMs for balanced polarimetry of the magnetometry signal resulting from the polarization rotation of the probe light. For such a metasurface design, the optical response is fully determined by the phase and amplitude of light in transmission. Figure 2b shows a schematic illustration of the unit cell structure of the metasurface, consisting of a single-crystalline silicon elliptical post of height HH and post diameters rxr_x and ryr_y along the xx and yy axes on a sapphire substrate. In the design, HH is fixed while rxr_x and ryr_y are tailored to achieve the desired φx\varphi_x and φy\varphi_y phase shifts for xx and yy-polarized waves, respectively. To implement beam splitting based on input polarization of a normally incident beam, the desired phase shifts are set to φx=−kxsin⁡θ\varphi_x=-kx\sin\theta for an xx-polarized beam and φy=kxsin⁡θ\varphi_y=kx\sin\theta for a yy-polarized beam, where the wavenumber is k=2π/λk=2\pi/\lambda and 2θ2\theta is the separation angle between the split beams. For this design, the phase shifts are invariant along yy. We note that the metasurface splits the incident light into beams with polarizations along xzxz (from the xx-polarized component of the incident beam) and yy (from the yy-polarized component of the incident beam). For simplicity, we will refer the xzxz-polarized transmitted beam as the xx-polarized beam for the remainder of the paper.

Operation of a metasurface polarizing beam splitter, unit cell, simulated transmittance and phase, and section of the metasurface polarization beam splitter design

Figure 2. (a) Operation of a metasurface polarizing beam splitter, which splits an incident beam into beams of orthogonal xzxz and yy polarizations. Note that for simplicity, we will refer the xzxz-polarized beam as the xx-polarized transmitted beam for the rest of the paper. (b) Illustration of a unit cell comprising of a silicon post on a transparent substrate (here, sapphire). The silicon post has an elliptical cross-section (principal axis lengths rxr_x and ryr_y) and height H. (c)-(d) Calculated normalized transmitted power (“Transmittance”) and phase shift of an incident xx- or yy-polarized plane wave, based on full-wave simulation of swept elliptical parameters with fixed lattice constant (a=400a = 400 nm) and post height (H=500H = 500 nm). (e) Top view of a section of the metasurface polarization beam splitter design.

Next, we construct the metasurface by sampling the phase profile using a square lattice of silicon elliptical posts of various diameters that implement the required phase shift at that position. As stated in [28], to avoid non-zero order diffraction and to achieve a better approximation of the phase profile, the sampling lattice constant aa should be smaller than the operating wavelength. In our case, we choose a=400 nma = 400\ \mathrm{nm} for the Rb D1-line (795 nm795\ \mathrm{nm}).

By varying the geometric parameters rx,ryr_x,r_y of the elliptical posts, we can impose independent phase shifts along the xx and yy polarization axes. Figure 2c and Figure 2d show the simulated transmitted power and phase shift of an array of elliptical posts with different axis radii from 40 nm to 140 nm for an incident linearly polarized (xx or yy) plane wave. We see directly from the figure that this platform provides a complete phase coverage independently over φx\varphi_x and φy\varphi_y while maintaining a relatively high transmission amplitude of >87%> 87\%. Elliptical posts of specific radius are selected to match the metasurface phase profile at their position by minimizing the squared error ϵ=∣tx−eiφx∣2+∣ty−eiφy∣2\epsilon= \lvert t_x - e^{i\varphi_x}\rvert^2 + \lvert t_y - e^{i\varphi_y}\rvert^2, where tit_i is the transmission coefficient of the elliptical post and φi\varphi_i is the calculated phase profile for polarization i=x,yi = x,y, respectively. The resulting metasurface consists of 2500×25002500 \times2500 posts (a portion of which is shown in Figure 2e) and is designed to achieve a 2θ=20∘2\theta= 20^\circ split angle between the xx and yy polarization components. For this design, the maximum ϵ\epsilon obtained is 0.0886 while the average ϵ\epsilon is 0.0166. These ϵ\epsilon values are limited by the mismatch between the desired phase and amplitude profiles and the discretized values in Figure 2c

and 2d, but are nonetheless sufficiently low to ensure good beam splitting performance while maintaining high transmission, as will be shown in the next section.

Simulated optical performance

To characterize the optical performance of our metasurface beam splitter, we performed finite-difference time domain (FDTD) simulations for a design with a device area of 16 μm×16 μm16\ \mu\mathrm{m} \times16\ \mu\mathrm{m} using a Gaussian beam source (see Supplementary Information S1 on justification of our simulated beam source). Our design can be extended to a much larger (>1 mm2>1\ \mathrm{mm}^{2}) device footprint, but this representative simulation area is chosen to limit computational time. The incident beam of wavelength λ=795 nm\lambda= 795\ \mathrm{nm} (D1 transition of 87Rb{}^{87}\mathrm{Rb}) is propagating in the zz-direction at normal incidence. We evaluated the transmission characteristics of the metasurface for different input polarization angles. Figure 3a represents the normalized transmitted far-field intensity for an incident linear polarization at 45∘45^{\circ} (comprising of an equal superposition of xx and yy polarizations). As expected, the designed metasurface splits the 45∘45^{\circ} linearly polarized incident beam into xx- and yy-polarized beams propagated along different directions. The split beams have a slightly different transmittance with a split ratio of 49% and 47% for xx and yy polarization respectively. The transmittance among various input polarization angles is shown in Figure 3b. The results for xx-polarized beam (respectively for yy-polarized beam) demonstrate that the transmitted intensity varies as the square of the cosine (respectively sine) of the polarization angle of the input beam. This is in good consistency with Malus law for linear polarizers.

3D far-field normalized intensity scattering patterns and normalized transmission for different polarization angles

Figure 3. (a) The 3D far-field normalized intensity scattering patterns for the 45-linearly polarized incident Gaussian beam under normal incidence. (b) The normalized transmission in far field for different polarization angles of the input beam. Each data point for the xx and yy-polarized beam is obtained by integrating the optical power within their respective scattered spot, then normalize it to the overall transmission power. The solid lines indicate sinusoidal fit to the data.

The performance shown here is for input beams of wavelength λ=795 nm\lambda= 795\ \mathrm{nm} at normal incidence, in which the simulated transmittance is over 80% exhibits a slight linear dichroism (83.3% for x−x-

polarized beam and 85.8% for yy-polarized beam). Polarization extinction ratio (PER) is another important performance metric for PBS devices. We define the PER for each output port as the light intensity of main polarization mode divided by the light intensity of the orthogonal polarization mode (see Supplementary Information S2). For normal incidence, the PER is 20.55 dB for xx polarization and 28.3 dB for yy polarization. The PER values of this design are limited by the discrete sampling of the metasurface and the residual phase error (ϵ\epsilon in § 3.1) when matching the geometric parameters of each elliptical post with the desired phase response.

In reality, the transmission efficiency and PER of the metasurface structure may vary with the incident angle as it has been reported in earlier works [15]. These deviations are significant considerations in an OPM, which may have axial misalignments between an input beam and the atomic cell. We have analyzed the transmission and polarization extinction of our design for different angles of incidence to evaluate the alignment requirements for achieving sensitive balanced polarimetry measurements. Figure 4c and Figure 4d show the transmittance and polarization extinction ratio at different incident angles from 0 to 10°. Both performance metrics suffer from degradation as the incident angle exceeds 5°, which is again attributed to the higher-order diffraction as the incidence condition deviates from the requirement for zero-order diffraction: λ≫acos⁡θ\lambda\gg\frac{a}{\cos\theta} (where θ\theta is the incident angle). Nevertheless, the polarization extinction ratio maintains a level of >17>17 dB over a range of 10°, an alignment condition that can be readily achieved in the actual experiment.

Figure 4. Simulated intensity transmission and polarization extinction ratio as function of the incident angle for (a) xx-polarized beam and (d) yy-polarized beam.

Sensitivity performance analysis

In this section, we evaluate how the optical performance of our proposed metasurface PBS affects balanced polarimetry and thereby the sensitivity and accuracy of an OPM. Our PBS design can is compatible with millimeter-scale, microfabricated Rb cells involving separate non-parallel [15] or inline pump and probe beams. For reasons specified in § 2, we focus on the magnetometry schemes that are compatible with inline pump-probe configurations such as the Mx [31], Bell-Bloom [32], SERF [33], and nonlinear magneto-optical rotation (NMOR) [34] OPMs. Of the above schemes proposed, SERF is an attractive candidate since it provides the highest sensitivities among OPMs and has been demonstrated to achieve sub-picotesla sensitivity in microfabricated cells [33]. Moreover, while the shot-noise-limited sensitivity of SERF magnetometry is expected to degrade with decreasing cell size [35], SERF operation relies on a high buffer gas pressure which is also necessary in very small (≲mm3\lesssim\mathrm{mm}^{3}) vapor cells to prevent decoherence from collisions of the atoms with the cell wall. A high buffer gas pressure would broaden atomic transitions and preclude the operation of NMOR [36]. Finally, SERF using elliptically polarized light has shown very promising results with device scale down to 5 mm [16, 31] and can require only a single optical beam to operate [18, 19], and thus highly compatible with nanophotonic integration.

We thus choose SERF magnetometry using a single elliptical beam as the platform for evaluating the sensitivity of a metasurface-integrated magnetometer [18]. In this scheme, an elliptically polarized light close to the 87Rb{}^{87}\mathrm{Rb} D1 transition interacts with a 87Rb{}^{87}\mathrm{Rb} vapor cell of optical path length ll and Rb number density nn to generate atomic spin polarization. This same optical beam is used to detect spin polarization via balanced polarimetry. An amplitude-modulating field is applied along the direction of magnetic field measurement (along xx) which must be transverse to the light propagation direction; all other field components are nulled. The optical signal is then detected using lock-in detection at the modulation frequency (ωmod\omega_{\mathrm{mod}}). The theory of operation for SERF magnetometry with elliptical light was worked out in [18] for the case of an ideal PBS with transmittance T=1T=1 and infinite polarization extinction ratio. In this scenario, the balanced polarimetry gives the polarization angle rotation ϕ\phi via the differential signal of the two outputs from the PBS:

D=E02e−σnlcos⁡2βsin⁡ϕ(1)\mathcal{D}=E_0^2 e^{-\sigma n l}\cos2\beta\sin\phi \tag*{(1)}

where ϕ\phi is proportional to the spin polarization along the optical axis (see Supplementary Information S3 for derivation); E0E_0 is the electric field amplitude; e−σnle^{-\sigma n l} is related to light absorption by Rb atoms (whereby σ\sigma is the photon absorption cross section for unpolarized Rb atoms); β\beta is the ellipticity of the light and is set to π/8\pi/8 [18]. In the low polarization limit, the signal D\mathcal{D} is linear in terms of spin polarization PzP_z. This optical rotation will allow us to determine the transverse magnetic field.

Effects of polarization-dependent transmittance and PER on magnetometry

Note that the differential signal D\mathcal{D} shown in Eq. (1) only includes the polarization rotation term induced by circular birefringence. Such simplicity cannot be assumed for our metasurface PBS which has a non-negligible transmittance difference for the two orthogonal linear polarization and polarization leakage. We thus modify the theory to incorporate these non-idealities. Let Tx,TyT_x,T_y be the transmittance for the xx and yy polarizations, bxb_x and byb_y be the percentage of the transmitted optical power that is leaked into the other output of the PBS for a pure xx and yy polarization input, respectively. bb is related to PER through b=1PER+1b = \frac{1}{\mathrm{PER}+1}. Then the outputs of the PBS become:

Ix=Tx(1−bx)Ix,in+TybyIy,inIy=TxbxIx,in+Ty(1−by)Iy,in(2)\begin{aligned} I_x &= T_x(1-b_x)I_{x,\mathrm{in}} + T_y b_y I_{y,\mathrm{in}}\\ I_y &= T_x b_x I_{x,\mathrm{in}} + T_y(1-b_y)I_{y,\mathrm{in}} \tag*{(2)} \end{aligned}

i.e. the two outputs are now a linear superposition of the light intensities along two orthogonal polarization axes. The direct consequence of this intensity mixture is that the differential signal will now contain an additional term due to circular dichroism that is proportional to σ\sigma. It can be shown that under this “imperfect PBS” model, the differential signal can be approximated as (see Supplementary Information S3 for the derivation):

D=E02e−σnl(ηcos⁡2βsin⁡ϕ+Ty(1−2by)−Tx(1−2bx)4σnlsin⁡2βPz)(3)\mathcal{D} = E_0^2 e^{-\sigma n l}\left(\eta\cos2\beta\sin\phi+ \frac{T_y(1-2b_y)-T_x(1-2b_x)}{4}\sigma n l\sin2\beta P_z\right) \tag*{(3)}

where

η=Tx(1−2bx)+Ty(1−2by)21−(Ty(1−2by)−Tx(1−2bx)cos⁡2β(Tx(1−2bx)+Ty(1−2by)))2(4)\eta= \frac{T_x(1-2b_x)+T_y(1-2b_y)}{2}\sqrt{1-\left(\frac{T_y(1-2b_y)-T_x(1-2b_x)}{\cos2\beta(T_x(1-2b_x)+T_y(1-2b_y))}\right)^2} \tag*{(4)}

ϕ\phi is the polarization rotation angle and is proportional to PzP_z. We see that the imperfect PBS results in two modifications in the expression of the differential signal: first, the original polarization rotation signal is attenuated by a factor of η\eta; second, the imperfect PBS introduces another term related to the change of the polarization ellipticity induced by the circular dichroism of the atomic medium, which is also proportional to PzP_z in the low polarization limit.

We will now compare the magnetometry signal of a metasurface-integrated magnetometer with one based on ideal optics (namely, a PBS with near unity transmittance, ultra-high PER, and no linear dichroism). We use identical excitation and cell conditions as in [18], in which the Rb vapor cell is filled with 300 Torr helium and 100 Torr nitrogen and heated to 200 °C. The laser frequency detuning is set to ν0−ν=45 GHz\nu_0-\nu=45\ \mathrm{GHz}. These conditions lead to a linewidth Δν\Delta\nu of 7.97 GHz, optical pumping rate of 880 Hz, and a spin relaxation rate of 1200 Hz. Fig. 5 shows the differential signal D\mathcal{D} as a function of the transverse magnetic field BxB_x for magnetometers based on ideal optics (red) and our metasurface design (blue) for a vapor cell with l=5 mml=5\ \mathrm{mm}. We can see from the Fig. 5 that the incorporation of the metasurface PBS into the magnetometer does not change the dispersive character of the signal and only modifies the signal amplitude by a scaling factor ξ\xi that is given by:

ξ=η+Ty(1−2by)−Tx(1−2bx)8Δνν0−ν(5)\xi=\eta+\frac{T_y(1-2b_y)-T_x(1-2b_x)}{8}\frac{\Delta\nu}{\nu_0-\nu} \tag*{(5)}

Figure 5. Simulated differential signal D\mathcal{D} with lock-in detection at the modulating frequency ωmod\omega_{\mathrm{mod}} as a function of BxB_x with an ideal PBS (red) and metasurface PBS (blue).

For our design, ξ≅0.837\xi\cong0.837. The metasurface polarization extinction ratios are still sufficiently high, such that bx,by≪1b_x,b_y\ll1. Additionally, there is with no significant linear dichroism ∣Tx−Ty∣≪1\lvert T_x-T_y\rvert\ll1 and the laser detuning is sufficiently larger than the pressure-broadened linewidth. Under these conditions, the signal amplitude is simply attenuated by the mean transmittance of x^\hat{x} and y^\hat{y} polarization: ξ≅Tx+Ty2\xi\cong\frac{T_x+T_y}{2}. Finally, it may be possible to further improve the metasurface design using adjoint optimization methods [37, 38, 39] that minimize the figure of merit (FOM) defined as

FOM=∣Ty(1−2by)−Tx(1−2bx)Tx(1−2bx)+Ty(1−2by)∣FOM = \left|\frac{T_y(1-2b_y)-T_x(1-2b_x)}{T_x(1-2b_x)+T_y(1-2b_y)}\right|

. This analysis can also serve as a useful guideline for designing nanophotonic components for other quantum sensors.

Impact of metasurface PBS on magnetometer noise

We now discuss the impact of the metasurface PBS on the various noise sources accompanying the atomic magnetometer signal. It is shown in [33] that in a single-beam, millimeter-scale magnetometer based on absorption measurement, the laser intensity noise dominates. The laser intensity noise can arise from laser current fluctuations or light polarization drifts that are converted into amplitude noise by a linear polarizer at the input. The SERF scheme we adopted for miniaturization in this paper uses balanced polarimetry as well as spin modulation with lock-in detection, which are capable of suppressing the intensity noise [18, 40]. A sensitivity of 7 fT/Hz7\ \mathrm{fT}/\sqrt{\mathrm{Hz}} was reported in a centimeter-scale cell in [18], with the dominant noise source being the Johnson noise from the magnetic shield.

The residual laser intensity noise will contribute to the overall technical noise (which also includes electronic noise) which will limit the signal-to-noise ratio (SNR) of the measurement. Since the metasurface PBS scales the differential signal amplitude by ξ≃0.837\xi\simeq0.837, we expect the SNR of the metasurface-integrated magnetometer to scale by a similar amount. Based on the inverse relationship between sensitivity and SNR [41], the magnetic field sensitivity will thus degrade by about a factor of 1.2.

In addition to its impact on detection, laser intensity noise also affects the optical pumping rate and light shifts experienced by atoms [42, 43], We calculated the effect of optical pumping rate variation in Supplementary Information S4 and showed that the resulting field measurement errors are not affected by the use of a metasurface PBS. The light shift effect is equivalent to a fictitious magnetic field along the light propagation direction (z) with its amplitude proportional to the laser intensity. In [18], the light shift effect is countered by applying a magnetic field in the opposite direction that minimizes the magnetic resonance linewidth. If the laser intensity noise is present, there will always be a small fictitious field δBz\delta B_z that is not balanced. Fortunately, if the noise amplitude is small enough such that γδBzτ≪1\gamma\delta B_z\tau\ll1, then it is shown in [44] that the induced change in atomic polarization PzP_z is of second order in δBz\delta B_z, rendering the error negligible.

Conclusion and outlook

We have demonstrated a metasurface-based balanced polarimeter design for a compact Rb magnetometer based on SERF and have connected its optical performance to the magnetometer accuracy and sensitivity. This design can be realized with electron-beam lithography and reactive-ion etching techniques on single-crystal silicon films grown on transparent substrates. It may be possible to incorporate the metasurface PBS as part of the glass wafer anodically bonded to the silicon housing during MEMS fabrication of mm-scale vapor cells [10]. Modeling of balanced polarimetry using simulated transmittance and PER shows that the nanophotonic component can be integrated into SERF magnetometry with only a 20% degradation in sensitivity. Our analysis of the magnetometry dependence of an imperfect PBS may inform future efforts to design and integrate nanophotonic polarization optics into atomic magnetometers and other atom-based sensors.

Acknowledgments

This work is supported by the Office of Naval Research under Grant No. N00014-20-1-2598 and the Wisconsin Alumni Research Foundation. The authors thank Mikhail Kats and Thad Walker for helpful discussions on the metasurface design and its suitability to atomic magnetometry platforms. We also thank Jinsheng Hu for a careful reading of our manuscript and providing valuable feedback on our analysis.

Disclosures The authors declare no conflicts of interest.

Data availability Data underlying the results presented in this paper are not publicly available at this time but may be obtained from the authors upon request.

Supplemental document See Supplementary Information.

Supplementary Information for “Analysis of atomic magnetometry using metasurface optics for balanced polarimetry”

Xuting Yang; Meryem Benelajla; Jennifer T. Choy

Supplementary v22

Plane-wave approximation

Here we justify our assumption that the phase profile φ(x,y)\varphi(x,y) of our metasurface polarizing beamsplitter that is designed for a normal plane wave incidence would still apply to the case where the incident beam has a Gaussian profile. Let us consider a Gaussian source polarized along the xx direction:

U(x,y,z)=E0x^w0w(z)exp⁡(−x2+y2w(z)2)exp⁡(−i(kz+kx2+y22R(z)−ψ(z)))(6)U(x,y,z)=E_0\hat{x}\frac{w_0}{w(z)}\exp\left(-\frac{x^2+y^2}{w(z)^2}\right)\exp\left(-i\left(kz+k\frac{x^2+y^2}{2R(z)}-\psi(z)\right)\right) \tag*{(6)}

where w0w_0 is the waist radius, w(z)=w01+(λzπw02)2w(z)=w_0\sqrt{1+\left(\frac{\lambda z}{\pi w_0^2}\right)^2} is the radius at which the field amplitudes decay to 1e\frac{1}{e} of their axial values, R(z)=z2+(πw02λ)2zR(z)=\frac{z^2+\left(\frac{\pi w_0^2}{\lambda}\right)^2}{z} is the radius of curvature, ψ(z)=arctan⁡(λzπw02)\psi(z)=\arctan\left(\frac{\lambda z}{\pi w_0^2}\right) is the Gouy phase.

Our main argument here is that U(x,y,z)\mathbf{U}(x,y,z) is a solution to the paraxial Helmholtz equation, and can thus be well-approximated by a normal incident plane wave plus a small component of paraxial wave:

U(x,y,z)=∬u(kx,ky)e−i(kxx+kyy+kzz) dkxdky=∬e−ikzu(kx,ky)e−i(kxx+kyy−12k(kx2+ky2)z) dkxdky(7)U(x,y,z)=\iint u(k_x,k_y)e^{-i(k_xx+k_yy+k_zz)}\,\mathrm{d}k_x\mathrm{d}k_y =\iint e^{-ik_zu(k_x,k_y)e^{-i\left(k_xx+k_yy-\frac{1}{2k}(k_x^2+k_y^2)z\right)}\,\mathrm{d}k_x\mathrm{d}k_y} \tag*{(7)}

where we have used the fact that kx,ky≪kzk_x,k_y\ll k_z.

We claim that the elliptical posts will impose the same phase shift φ(x,y)=∓kxsin⁡Θ\varphi(x,y)=\mp kx\sin\Theta for a paraxial plane wave, so that the gaussian source after transmitting through the metasurface will become:

U′(x,y,z)=∬e−ik(z∓xsin⁡Θ)u(kx,ky)e−i(kxx+kyy−12k(kx2+ky2)z) dkxdkyU'(x,y,z)=\iint e^{-ik(z\mp x\sin\Theta)}u(k_x,k_y)e^{-i\left(k_xx+k_yy-\frac{1}{2k}(k_x^2+k_y^2)z\right)}\,\mathrm{d}k_x\mathrm{d}k_y

which is just the gaussian beam deflected by angle ∓Θ\mp\Theta. In what follows, we justify our claim. Let us quantify this argument by calculating the Fourier component u(θ)\mathbf{u}(\theta) of a Gaussian beam, where θ\theta indicates the angle between the wavevector and the propagation direction z^\hat{z}. We write the k-vector in spherical basis: kx=Ksin⁡θcos⁡φk_x=K\sin\theta\cos\varphi, ky=Ksin⁡θsin⁡φk_y=K\sin\theta\sin\varphi, kz=Kcos⁡θk_z=K\cos\theta. Here φ\varphi is the azimuth angle.

u(K,θ)=∭U(x,y,z)ei(kxx+kyy+kzz) dxdydz=E0w0∫−∞+∞1w(z)ei(Kcos⁡θ−k)z+ψ(z) dz×∬e−x2+y2w(z)2ei(Ksin⁡θcos⁡φx+Ksin⁡θsin⁡φy)−k(x2+y2)2R(z) dxdy(8)\begin{aligned} u(K,\theta)=\iiint U(x,y,z)e^{i(k_xx+k_yy+k_zz)}\,\mathrm{d}x\mathrm{d}y\mathrm{d}z \\ &= E_{0}w_{0}\int_{-\infty}^{+\infty}\frac{1}{w(z)}e^{i(K\cos\theta-k)z+\psi(z)}\,\mathrm{d}z \times\iint e^{-\frac{x^{2}+y^{2}}{w(z)^{2}}}e^{i(K\sin\theta\cos\varphi x+K\sin\theta\sin\varphi y)-\frac{k(x^{2}+y^{2})}{2R(z)}}\,\mathrm{d}x\mathrm{d}y \tag*{(8)} \end{aligned}

It can be proven that

∣u(K,θ)∣=C(w0,λ,E0)∣g(z,θ)∣e−K2w024sin⁡2θ(9)\lvert u(K,\theta)\rvert=C(w_{0},\lambda,E_{0})\lvert g(z,\theta)\rvert e^{-\frac{K^{2}w_{0}^{2}}{4}\sin^{2}\theta} \tag*{(9)}

Here C(w0,λ,E0)C(w_{0},\lambda,E_{0}) is a constant that only depends on the incident Gaussian beam parameters. g=g=

∫−∞+∞ei(Kcos⁡θ−k)z+ψ(z)1+(λzπw02)2 dz\int_{-\infty}^{+\infty}\frac{e^{i(K\cos\theta-k)z+\psi(z)}}{\sqrt{1+\left(\frac{\lambda z}{\pi w_{0}^{2}}\right)^{2}}}\,\mathrm{d}z

is a complex function of θ\theta.

If α=Kcos⁡θ−k≠0\alpha=K\cos\theta-k\ne0, then g(α)=∫−∞+∞ei(αz+ψ(z))1+(λzπw02)2 dzg(\alpha)=\int_{-\infty}^{+\infty}\frac{e^{i(\alpha z+\psi(z))}}{\sqrt{1+\left(\frac{\lambda z}{\pi w_{0}^{2}}\right)^{2}}}\,\mathrm{d}z converges, therefore the Fourier components that matter are the ones with K=kcos⁡θK=\frac{k}{\cos\theta}. We now have:

∣u(θ)∣∝e−k2w024tan⁡2θ(10)\lvert u(\theta)\rvert\propto e^{-\frac{k^{2}w_{0}^{2}}{4}\tan^{2}\theta} \tag*{(10)}

The angular dependence of the Fourier component decays very fast with respect to θ\theta. We define a cutoff angle θ0\theta_{0} where its corresponding Fourier coefficient is only e−4≈1.8%e^{-4}\approx1.8\% of that of the normal component. Then:

θ0=arctan⁡(4kw0)(11)\theta_{0}=\arctan\left(\frac{4}{kw_{0}}\right) \tag*{(11)}

For our simulation, w0=4 μmw_{0}=4\,\mu\mathrm{m} and k=7.9×106 m−1k=7.9\times10^{6}\,\mathrm{m}^{-1}, the cutoff angle θ0=7∘\theta_{0}=7^\circ. For a realistic beam size w0=1 mmw_{0}=1\,\mathrm{mm} in the magnetometer experiment, θ0=0.03∘\theta_{0}=0.03^\circ. It follows that the Gaussian source in the actual experiment is very well approximated by a normal incident plane wave. Indeed, simulated phase shift of a 795-nm plane wave with incident angle at the cutoff angle θ0=0.03∘\theta_{0}=0.03^\circ shows less than 10−610^{-6} deviation from that for a normally incident plane wave.

Determination of transmittance and polarization extinction ratio

In this section we describe our method for calculating the transmittance TT and the polarization extinction ratio (PER) of the metasurface PBS. The transmittance T0T_{0} from the transmission of the field through the metasurface is first extracted from a field monitor placed a few wavelengths away from the metasurface. In the far-field projection, the transmitted field intensity ∣E∣2\lvert E\rvert^{2} is integrated at the two PBS outputs whose locations are determined by the splitting angle 2θ2\theta. The integration area is determined through the solid angle Ω\Omega of the projection hemisphere. We choose Ω=2π(1−cos⁡7∘)\Omega=2\pi(1-\cos7^\circ) (half angle 7∘7^\circ) to ensure we have covered most of the scattered light and the two integration areas do not overlap. The reported transmittance values in the main text take into account both the initial transmittance T0\mathbf{T}_0 and the fraction of intensity within the solid angle:

T=T0×∫cone∣E∣2∫hemisphere∣E∣2(12)T = T_0 \times\frac{\int_{\mathrm{cone}} |E|^2}{\int_{\mathrm{hemisphere}} |E|^2} \tag*{(12)}

We now define ImainI_{main} to be the integrated intensity in the far field that corresponds to the main polarization mode and IleakI_{leak} to be the intensity corresponding to the orthogonal polarization mode, then the PER is calculated as:

PER=ImainIleak(13)PER = \frac{I_{main}}{I_{leak}} \tag*{(13)}

Derivation of differential signal for an imperfect PBS

In this section we show the derivation of the differential signal between the output ports of an imperfect PBS, for SERF magnetometry with a single elliptical beam [1]. We write an electric field with arbitrary polarization and amplitude in the xx and yy polarization basis: E=c1x^+c2iy^E = c_1\hat{x} + c_2i\hat{y} where c1c_1 and c2c_2 are complex numbers.

If the optical axes of the PBS are oriented with respect to the x−yx-y coordinate by angle δ\delta, then the two outputs of the metasurface PBS are:

I1=P(Tx(1−bx)∣c1cos⁡δ+ic2sin⁡δ∣2+Tyby∣−c1sin⁡δ+ic2cos⁡δ∣2)I2=P(Txbx∣c1cos⁡δ+ic2sin⁡δ∣2+Ty(1−by)∣−c1sin⁡δ+ic2cos⁡δ∣2)(14)\begin{aligned} I_1 &= \mathcal{P}\left(T_x(1-b_x)|c_1\cos\delta+ ic_2\sin\delta|^2 + T_yb_y|-c_1\sin\delta+ ic_2\cos\delta|^2\right) \\ I_2 &= \mathcal{P}\left(T_xb_x|c_1\cos\delta+ ic_2\sin\delta|^2 + T_y(1-b_y)|-c_1\sin\delta+ ic_2\cos\delta|^2\right) \tag*{(14)} \end{aligned}

Here P\mathcal{P} is some constant is related to vacuum permittivity and detection efficiency. With the differential signal being:

D=I1−I2=P[Tx(1−2bx)∣c1cos⁡δ+ic2sin⁡δ∣2−Ty(1−2by)∣−c1sin⁡δ+ic2cos⁡δ∣2]=P[Tx(1−2bx)(∣c1∣2cos⁡2δ+i(c‾1c2−c1c‾2)sin⁡δcos⁡δ+∣c2∣2sin⁡2δ)−Ty(1−2by)(∣c1∣2sin⁡2δ+i(c1c‾2−c‾1c2)sin⁡δcos⁡δ+∣c2∣2cos⁡2δ)](15)\begin{aligned} \mathcal{D} &= I_1-I_2 \\ &= \mathcal{P}\left[T_x(1-2b_x)|c_1\cos\delta+ ic_2\sin\delta|^2 - T_y(1-2b_y)|-c_1\sin\delta+ ic_2\cos\delta|^2\right] \\ &= \mathcal{P}\left[T_x(1-2b_x)\left(|c_1|^2\cos^2\delta+ i(\overline{c}_1c_2-c_1\overline{c}_2)\sin\delta\cos\delta+ |c_2|^2\sin^2\delta\right) \right. \\ &\qquad\left. -T_y(1-2b_y)\left(|c_1|^2\sin^2\delta+ i(c_1\overline{c}_2-\overline{c}_1c_2)\sin\delta\cos\delta+ |c_2|^2\cos^2\delta\right)\right] \tag*{(15)} \end{aligned}

In the absence of an atomic medium, ∣c1∣2=cos⁡2β|c_1|^2=\cos^2\beta, ∣c2∣2=sin⁡2β|c_2|^2=\sin^2\beta, c‾1c2−c1c‾2=0\overline{c}_1c_2-c_1\overline{c}_2=0. Let D=0\mathcal{D}=0 and we get the expression for δ\delta that balances the two outputs:

tan⁡2δ=Tx(1−2bx)cos⁡2β−Ty(1−2by)sin⁡2βTy(1−2by)cos⁡2β−Tx(1−2bx)sin⁡2β(16)\tan^2\delta= \frac{T_x(1-2b_x)\cos^2\beta- T_y(1-2b_y)\sin^2\beta}{T_y(1-2b_y)\cos^2\beta- T_x(1-2b_x)\sin^2\beta} \tag*{(16)}

The interaction of the field with rubidium atoms causes polarization rotation and ellipticity change, with the coefficients now being:

∣c1∣2=12[(e−nσl(1+Pz)+e−nσl(1−Pz))+(e−nσl(1+Pz)−e−nσl(1−Pz))sin⁡2β+2e−nσlcos⁡2βcos⁡ϕ](17)\lvert c_1\rvert^2 = \frac{1}{2}\left[\left(e^{-n\sigma l(1+P_z)}+e^{-n\sigma l(1-P_z)}\right)+\left(e^{-n\sigma l(1+P_z)}-e^{-n\sigma l(1-P_z)}\right)\sin2\beta+ 2e^{-n\sigma l}\cos2\beta\cos\phi\right] \tag*{(17)}
∣c2∣2=12[(e−nσl(1+Pz)+e−nσl(1−Pz))+(e−nσl(1+Pz)−e−nσl(1−Pz))sin⁡2β−2e−nσlcos⁡2βcos⁡ϕ](18)\lvert c_2\rvert^2 = \frac{1}{2}\left[\left(e^{-n\sigma l(1+P_z)}+e^{-n\sigma l(1-P_z)}\right)+\left(e^{-n\sigma l(1+P_z)}-e^{-n\sigma l(1-P_z)}\right)\sin2\beta- 2e^{-n\sigma l}\cos2\beta\cos\phi\right] \tag*{(18)}
c‾1c2−c1c‾2=−2ie−nσlcos⁡2βsin⁡ϕ(19)\overline{c}_1c_2-c_1\overline{c}_2=-2ie^{-n\sigma l}\cos2\beta\sin\phi \tag*{(19)}

where ϕ=crefnlPzRe⁡(L(ν))\phi=c r_e f n l P_z \operatorname{Re}(L(\nu)) is the polarization rotation angle defined in [1]. Here cc is the speed of light in vacuum; rer_e is the classical electron radius; f≃13f \simeq\frac{1}{3} is the oscillator strength of the rubidium D1 transition; ll is the optical path length; nn is the Rb number density; PzP_z is the atomic spin polarization along z direction; L(ν)=1ν0−ν+iΔν2L(\nu)=\frac{1}{\nu_0-\nu+i\frac{\Delta\nu}{2}} is the pressure-broadened Lorentzian profile with a full width at half maximum Δν\Delta\nu centered at ν0\nu_0. Plug in the expressions for c1c_1, c2c_2 and δ\delta into expression Eq. (15), and select P\mathcal{P} such that our result reduces to the expression given in [1] when Tx=Ty=1T_x=T_y=1, bx=by=0b_x=b_y=0, we have:

D=18E02[(Tx(1−2bx)−Ty(1−2by))×(e−nσl(1+Pz)+e−nσl(1−Pz)+sin⁡2β(e−nσl(1+Pz)−e−nσl(1−Pz))+2(Ty(1−2by)−Tx(1−2bx))e−nσlcos⁡ϕ)+4(Tx(1−2bx)+Ty(1−2by))×1−(Ty(1−2by)−Tx(1−2bx)cos⁡2β(Tx(1−2bx)+Ty(1−2by)))2e−nσlcos⁡2βsin⁡ϕ](20)\begin{aligned} \mathcal{D}={}&\frac{1}{8}E_0^2\left[(T_x(1-2b_x)-T_y(1-2b_y))\right.\\ &\quad\times\left(e^{-n\sigma l(1+P_z)}+e^{-n\sigma l(1-P_z)}+\sin2\beta\left(e^{-n\sigma l(1+P_z)}-e^{-n\sigma l(1-P_z)}\right)\right.\\ &\qquad\left.+2(T_y(1-2b_y)-T_x(1-2b_x))e^{-n\sigma l}\cos\phi\right)\\ &\quad+4\left(T_x(1-2b_x)+T_y(1-2b_y)\right)\\ &\qquad\left.\times\sqrt{1-\left(\frac{T_y(1-2b_y)-T_x(1-2b_x)}{\cos2\beta(T_x(1-2b_x)+T_y(1-2b_y))}\right)^2e^{-n\sigma l}\cos2\beta\sin\phi}\right] \tag*{(20)} \end{aligned}

Expanding and keep the first order of PzP_z, we have:

D=E02e−σnl(Tx(1−2bx)+Ty(1−2by)2)×1−(Ty(1−2by)−Tx(1−2bx)cos⁡2β(Tx(1−2bx)+Ty(1−2by)))2cos⁡2βsin⁡ϕ+Ty(1−2by)−Tx(1−2bx)4σnlsin⁡2βPz(21)\begin{aligned} \mathcal{D}={}&E_0^2e^{-\sigma n l}\left(\frac{T_x(1-2b_x)+T_y(1-2b_y)}{2}\right)\\ &\quad\times\sqrt{1-\left(\frac{T_y(1-2b_y)-T_x(1-2b_x)}{\cos2\beta(T_x(1-2b_x)+T_y(1-2b_y))}\right)^2}\cos2\beta\sin\phi\\ &\quad+\frac{T_y(1-2b_y)-T_x(1-2b_x)}{4}\sigma n l\sin2\beta P_z \tag*{(21)} \end{aligned}

For ϕ,σnlPz≪1\phi,\sigma n l P_z\ll1, D\mathcal{D} reduces to

D=ξE02e−σnlcos⁡2βsin⁡ϕ(22)\mathcal{D}=\xi E_0^2e^{-\sigma n l}\cos2\beta\sin\phi \tag*{(22)}

where ξ\xi is defined in Eq. (5) in the main text.

Let us now discuss what conditions should the transmittance and PER of the PBS satisfy to generate a dispersive signal with discernible amplitude. Note that under the SERF condition, the atomic vapor is usually dense enough that the modification of the optical absorption due to spin polarization Λ=nσlPz\Lambda= n\sigma lP_z is no longer small enough for the first order approximation to remain valid (except for sufficiently small vapor cells, see Figure S1). Therefore, the polarimetry signal from circular dichroism (which is the one related to Im⁡(L(ν))\operatorname{Im}(L(\nu))) is no longer dispersive due to the even power terms in the expansion. We thus require this term to be suppressed compared to the term due to polarization rotation:

Simulated differential signal due to circular dichroism

Figure S1. Simulated differential signal D\mathcal{D} due to circular dichroism for a vapor cell with optical path length of 5 mmmm(blue) and 50 μm\mu m(red). The figure is not to scale and only shows the overall shape of the signal.

∣Ty(1−2by)−Tx(1−2bx)∣8tan⁡2βΔνν0−ν≪Tx(1−2bx)+Ty(1−2by)21−(Ty(1−2by)−Tx(1−2bx)cos⁡2β(Tx(1−2bx)+Ty(1−2by)))2(23)\frac{\left|T_y(1-2b_y)-T_x(1-2b_x)\right|}{8}\tan2\beta\frac{\Delta\nu}{\nu_0-\nu}\ll\frac{T_x(1-2b_x)+T_y(1-2b_y)}{2}\sqrt{1-\left(\frac{T_y(1-2b_y)-T_x(1-2b_x)}{\cos2\beta\left(T_x(1-2b_x)+T_y(1-2b_y)\right)}\right)^2} \tag*{(23)}

In addition, the relative amplitude A\mathcal{A} of the polarization rotation signal

A=e−σnlcos⁡2βTx(1−2bx)+Ty(1−2by)2×1−(Ty(1−2by)−Tx(1−2bx)cos⁡2β(Tx(1−2bx)+Ty(1−2by)))2(24)\mathcal{A}=e^{-\sigma n l\cos2\beta}\frac{T_x(1-2b_x)+T_y(1-2b_y)}{2}\times\sqrt{1-\left(\frac{T_y(1-2b_y)-T_x(1-2b_x)}{\cos2\beta\left(T_x(1-2b_x)+T_y(1-2b_y)\right)}\right)^2} \tag*{(24)}

should be maximized once Eq. (23) is satisfied.

Using the laser detuning, ellipticity, and linewidth specified in [1], we rewrite the condition in Eq. (23) in terms of the figure of merit introduced in § 4 of the main text:

FOM=∣Ty(1−2by)−Tx(1−2bx)Tx(1−2bx)+Ty(1−2by)∣≪0.707(25)FOM = \left| \frac{T_y(1-2b_y)-T_x(1-2b_x)}{T_x(1-2b_x)+T_y(1-2b_y)} \right| \ll0.707 \tag*{(25)}

Considering that the FOMFOM is bounded to ≤1\le1, we therefore see that Eq. (23) can be easily satisfied. In addition, the signal can be further optimized by choosing a different ellipticity β\beta and detuning ν0−ν\nu_0-\nu. For a sufficiently small vapor cell such that Λ=nσlPz≪1\Lambda=n\sigma lP_z\ll1, Eq. (23) is no longer required, and we can instead maximize the signal in the linear PzP_z regime:

D=ξE02e−σnlcos⁡2βsin⁡ϕ(26)\mathcal{D}=\xi E_0^2 e^{-\sigma n l}\cos2\beta\sin\phi \tag*{(26)}

Effect of laser intensity variation on the pumping rate and the differential signal

The differential signal in Eq. (26) has a dependence on the polarization rotation angle ϕ\phi, whose expression has been derived in [1]:

ϕ=crefnlPzν0−ν(ν0−ν)2+(Δν2)2(27)\phi=cr_e f n l P_z\frac{\nu_0-\nu}{(\nu_0-\nu)^2+\left(\frac{\Delta\nu}{2}\right)^2} \tag*{(27)}

Here rer_e is the classical electron radius, ff is the oscillator strength of the rubidium D1 transition. The component of PzP_z at modulation frequency is given by

Pz=2sRγBx(R+1T2)2γ2Bx2(R+1T2)2+1(28)P_z=\frac{2sR\gamma B_x\left(R+\frac{1}{T_2}\right)^2}{\gamma^2B_x^2\left(R+\frac{1}{T_2}\right)^2+1} \tag*{(28)}

Here γ\gamma is the electron gyromagnetic ratio, Q(P)=6Q(P)=6 is the nuclear slowdown factor for 87Rb{}^{87}\mathrm{Rb} in the low polarization limit, s=iE⃗×E⃗∗E02=−sin⁡2βz^s=i\frac{\vec{E}\times\vec{E}^{*}}{E_0^2}=-\sin2\beta\hat{z} is the photon spin, T2T_2 is the transverse spin relaxation time, R=σcϵ0E022hνR=\frac{\sigma c\epsilon_0E_0^2}{2h\nu} is the optical pumping rate for unpolarized atoms where σ=crefΔν2(ν0−ν)2+(Δν2)2\sigma=\frac{cr_ef\frac{\Delta\nu}{2}}{(\nu_0-\nu)^2+\left(\frac{\Delta\nu}{2}\right)^2}.

For a relative intensity variation ϵint=ΔII=ΔRR\epsilon_{int}=\frac{\Delta I}{I}=\frac{\Delta R}{R} (since R∝IR\propto I), we have a field measurement error of:

e(Bx)=∂D∂RΔR1∣∂D∂B∣(29)e(B_x)=\frac{\partial\mathcal{D}}{\partial R}\Delta R\frac{1}{\left|\frac{\partial\mathcal{D}}{\partial B}\right|} \tag*{(29)}

For ϵint=1%\epsilon_{int} = 1\%, Figure 2 shows the field measurement error e(Bx)e(B_x) as a function of BxB_x. We can see that the relationship is mostly linear, indicating a constant relative error of e(Bx)Bx=1.16%\frac{e(B_x)}{B_x} = 1.16\%. We also see in Figure S2 that this error is almost identical for the metasurface PBS as well as ideal PBS.

Simulated magnetic field measurement error due to variation in transmitted light power and optical pumping rate

Figure S2. Simulated magnetic field measurement error due to variation in transmitted light power and optical pumping rate.

References for the Supplementary Information

  1. V. Shah and M. V. Romalis, "Spin-exchange relaxation-free magnetometry using elliptically polarized light," Phys. Rev. A 80(1), 013416 (2009).

References

  1. [1]I. K. Kominis, T. W. Kornack, J. C. Allred, and M. V. Romalis, "A subfemtotesla multichannel atomic magnetometer," Nature 422(6932), 596–599 (2003).pubmed.ncbi.nlm.nih.gov/12686995
  2. [2]S. Knappe, T. H. Sander, O. Kosch, F. Wiekhorst, J. Kitching, and L. Trahms, "Cross-validation of microfabricated atomic magnetometers with superconducting quantum interference devices for biomagnetic applications," Appl. Phys. Lett. 97(13), 133703 (2010).DOI
  3. [3]C. N. Johnson, P. D. D. Schwindt, and M. Weisend, "Multi-sensor magnetoencephalography with atomic magnetometers," Phys. Med. Biol. 58(17), 6065–6077 (2013).DOI
  4. [4]M. Purucker, B. Langlais, N. Olsen, G. Hulot, and M. Mandea, "The southern edge of cratonic North America: Evidence from new satellite magnetometer observations," Geophysical Research Letters 29(15), 56-1-56–4 (2002).DOI
  5. [5]C. Tyren, "Magnetic terrain navigation," in Proceedings of the 1987 5th International Symposium on Unmanned Untethered Submersible Technology (1987), 5, pp. 245–256.
  6. [6]D. Budker and M. Romalis, "Optical magnetometry," Nature Phys 3(4), 227–234 (2007).
  7. [7]S. J. Seltzer, "Developments in alkali -metal atomic magnetometry," Ph.D., Princeton University (n.d.).
  8. [8]D. Hunter, S. Piccolomo, J. D. Pritchard, N. L. Brockie, T. E. Dyer, and E. Riis, "Free-Induction-Decay Magnetometer Based on a Microfabricated Cs Vapor Cell," Phys. Rev. Applied 10(1), 014002 (2018).DOI
  9. [9]W. C. Griffith, S. Knappe, and J. Kitching, "Femtotesla atomic magnetometry in a microfabricated vapor cell," Opt. Express 18(26), 27167–27172 (2010).
  10. [10]P. D. D. Schwindt, S. Knappe, V. Shah, L. Hollberg, J. Kitching, L.-A. Liew, and J. Moreland, "Chip-scale atomic magnetometer," Appl. Phys. Lett. 85(26), 6409–6411 (2004).
  11. [11]Y. Xuan, R. Sengupta, and Y. Fallah, "Making indoor maps with portable accelerometer and magnetometer," in 2010 Ubiquitous Positioning Indoor Navigation and Location Based Service (2010), pp. 1–7.DOI
  12. [12]J. F. D. F. Araujo, M. C. Costa, S. R. W. Louro, and A. C. Bruno, "A portable Hall magnetometer probe for characterization of magnetic iron oxide nanoparticles," Journal of Magnetism and Magnetic Materials 426, 159–162 (2017).DOI
  13. [13]S. Felice, R. Rossi, and G. Crisi, "Assessment of movement-induced time-varying magnetic fields exposure in magnetic fields exposure in magnetic resonance imaging by a commercial portable magnetometer," Radiation Protection Dosimetry 185(3), 326–330 (2019).
  14. [14]J. Hu, J. Lu, Z. Liang, L. Liu, W. Wang, P. Zhou, and M. Ye, "Integrated Polarization-Splitting Grating Coupler for Chip-Scale Atomic Magnetometer," Biosensors 12(7), 529 (2022).DOI
  15. [15]Z. Liang, B. Zhou, J. Lu, Y. Liu, J. Hu, P. Zhou, W. Wang, L. Liu, G. Hu, and M. Ye, "Metasurface enabled on-chip double-beam scheme for SERF atomic magnetometer," Optics Communications 525, 128850 (2022).DOI
  16. [16]Y. Sebbag, A. Naiman, E. Talker, Y. Barash, and U. Levy, "Chip-Scale Integration of Nanophotonic-Atomic Magnetic Sensors," ACS Photonics 8(1), 142–146 (2021).DOI
  17. [17]Y. Sebbag, E. Talker, A. Naiman, Y. Barash, and U. Levy, "Demonstration of an integrated nanophotonic chip-scale alkali vapor magnetometer using inverse design," Light Sci Appl 10(1), 54 (2021).DOI
  18. [18]V. Shah and M. V. Romalis, "Spin-exchange relaxation-free magnetometry using elliptically polarized light," Phys. Rev. A 80(1), 013416 (2009).arxiv.org/abs/0903.2447
  19. [19]C. Johnson, P. D. D. Schwindt, and M. Weisend, "Magnetoencephalography with a two-color pump-probe, fiber-coupled atomic magnetometer," Appl. Phys. Lett. 97(24), 243703 (2010).DOI
  20. [20]P. Knapkiewicz, "Technological Assessment of MEMS Alkali Vapor Cells for Atomic References," Micromachines 10(1), 25 (2019).DOI
  21. [21]M. T. Hummon, S. Kang, D. G. Bopp, Q. Li, D. A. Westly, S. Kim, C. Fredrick, S. A. Diddams, K. Srinivasan, V. Aksyuk, and J. E. Kitching, "Photonic chip for laser stabilization to an atomic vapor with 10-11 instability," Optica, OPTICA 5(4), 443–449 (2018).DOI
  22. [22]R. Zektzer, N. Mazurski, Y. Barash, and U. Levy, "Nanoscale atomic suspended waveguides for improved vapour coherence times and optical frequency referencing," Nat. Photon. 15(10), 772–779 (2021).
  23. [23]K. Gallacher, P. F. Griffin, E. Riis, M. Sorel, and D. J. Paul, "Silicon nitride waveguide polarization rotator and polarization beam splitter for chip-scale atomic systems," APL Photonics 7(4), 046101 (2022).DOI
  24. [25]M. Khorasaninejad, W. T. Chen, R. C. Devlin, J. Oh, A. Y. Zhu, and F. Capasso, "Metalenses at visible wavelengths: Diffraction-limited focusing and subwavelength resolution imaging," Science 352(6290), 1190–1194 (2016).DOI
  25. [26]D. Lin, P. Fan, E. Hasman, and M. L. Brongersma, "Dielectric gradient metasurface optical elements," Science 345(6194), 298–302 (2014).DOI
  26. [27]A. Arbabi, Y. Horie, A. J. Ball, M. Bagheri, and A. Faraon, "Subwavelength-thick lenses with high numerical apertures and large efficiency based on high-contrast transmitarrays," Nat Commun 6(1), 7069 (2015).DOI
  27. [28]A. Arbabi, Y. Horie, M. Bagheri, and A. Faraon, "Dielectric metasurfaces for complete control of phase and polarization with subwavelength spatial resolution and high transmission," Nature Nanotech 10(11), 937–943 (2015).DOI
  28. [29]L. Wang, S. Kruk, H. Tang, T. Li, I. Kravchenko, D. N. Neshev, and Y. S. Kivshar, "Grayscale transparent metasurface holograms," Optica, OPTICA 3(12), 1504–1505 (2016).DOI
  29. [30]L. Zhu, X. Liu, B. Sain, M. Wang, C. Schlickriede, Y. Tang, J. Deng, K. Li, J. Yang, M. Holynski, S. Zhang, T. Zentgraf, K. Bongs, Y.-H. Lien, and G. Li, "A dielectric metasurface optical chip for the generation of cold atoms," Science Advances 6(31), eabb6667 (2020).DOI
  30. [31]D. Arnold, S. Siegel, E. Grisanti, J. Wrachtrup, and I. Gerhardt, "A rubidium Mx-magnetometer for measurements on solid state spins," Review of Scientific Instruments 88(2), 023103 (2017).DOI
  31. [32]R. Jimenez-Martinez, W. C. Griffith, Y.-J. Wang, S. Knappe, J. Kitching, K. Smith, and M. D. Prouty, "Sensitivity Comparison of Mx and Frequency-Modulated Bell–Bloom Cs Magnetometers in a Microfabricated Cell," IEEE Transactions on Instrumentation and Measurement 59(2), 372–378 (2010).
  32. [33]V. Shah, S. Knappe, P. D. D. Schwindt, and J. Kitching, "Subpicotesla atomic magnetometry with a microfabricated vapour cell," Nature Photon 1(11), 649–652 (2007).DOI
  33. [34]D. Budker, D. F. Kimball, V. V. Yashchuk, and M. Zolotorev, "Nonlinear magneto-optical rotation with frequency-modulated light," Phys. Rev. A 65(5), 055403 (2002).DOI
  34. [35]J. C. Allred, R. N. Lyman, T. W. Kornack, and M. V. Romalis, "High-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation," Phys. Rev. Lett. 89(13), 130801 (2002).pubmed.ncbi.nlm.nih.gov/12225013
  35. [36]Defense Technical Information Center, DTIC ADA544874: Development of a Micro-Fabricated Total-Field Magnetometer (2011).
  36. [37]C. M. Lalau-Keraly, S. Bhargava, O. D. Miller, and E. Yablonovitch, "Adjoint shape optimization applied to electromagnetic design," Opt. Express, OE 21(18), 21693–21701 (2013).DOI
  37. [38]M. Mansouree, A. McClung, S. Samudrala, and A. Arbabi, "Large-Scale Parametrized Metasurface Design Using Adjoint Optimization," ACS Photonics 8(2), 455–463 (2021).DOI
  38. [39]R. A. Wambold, Z. Yu, Y. Xiao, B. Bachman, G. Jaffe, S. Kolkowitz, J. T. Choy, M. A. Eriksson, R. J. Hamers, and M. A. Kats, "Adjoint-optimized nanoscale light extractor for nitrogen-vacancy centers in diamond," Nanophotonics 10(1), 393–401 (2021).
  39. [40]Y. Chen, L. Zhao, N. Zhang, M. Yu, Y. Ma, X. Han, M. Zhao, Q. Lin, P. Yang, and Z. Jiang, "Single beam Cs-Ne SERF atomic magnetometer with the laser power differential method," Opt. Express, OE 30(10), 16541–16552 (2022).DOI
  40. [41]V. G. Lucivero, P. Anielski, W. Gawlik, and M. W. Mitchell, "Shot-noise-limited magnetometer with sub-picotesla sensitivity at room temperature," Review of Scientific Instruments 85(11), 113108 (2014).DOI
  41. [42]S. P. Krzyzewski, A. R. Perry, V. Gerginov, and S. Knappe, "Characterization of noise sources in a microfabricated single-beam zero-field optically-pumped magnetometer," Journal of Applied Physics 126(4), 044504 (2019).DOI
  42. [43]R. Wylie, "The development of a multichannel atomic magnetometer array for fetal magnetocardiography," University of Wisconsin--Madison (2012).
  43. [44]C. Cohen-Tannoudji, J. Dupont-Roc, S. Haroche, and F. Laloë, "Diverses résonances de croisement de niveaux sur des atomes pompés optiquement en champ nul. I. Théorie," Rev. Phys. Appl. (Paris) 5(1), 95–101 (1970).

Paper details

vlnc:W_w8q49cp6
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 0

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents