Abstract
Frontier AI governance agreements require compute verification techniques that allow an external observer to confirm that a hardware operator does not run prohibited workloads. Off-chip, analogue hardware signals, such as power draw, have been proposed as a potential information channel for compute verification. Such signals can be measured externally, without the operator's cooperation. We show that the supply current drawn by a GPU can be used to verify the work declared by the GPU operator, without requiring examples of prohibited workloads or evasion strategies. We record 23.4 h of GPU current with a Rogowski coil under idle, training and inference workloads. We consider five evasion strategies an operator might use to disguise prohibited training. We show that a one-class model fitted to the current draw of permitted, declared work (idle and inference) flags at least 99.9% of windows of prohibited training, including training hidden by the five evasion strategies. As a continuous monitor across successive windows, it detects all 188 episodes of prohibited training hidden by time-sharing with declared inference, with a median delay of 3.0 s, and raises one alarm in 8.8 h of declared work. Incomplete or corrupt recordings of the declared work can undermine verification. An incomplete recording fails loudly; with idle missing, the monitor is in alarm for 99.97% of declared idle. A corrupt recording can fail silently; if the operator runs training during the recording, the monitor can miss hidden training while raising no alarm on declared work. These results suggest that operator declarations together with external analogue sensing might offer a practical route to compute verification.
Introduction
Agreements on AI compute will need methods to verify how GPUs are used ([14, 2]). The operator states the work that a GPU runs, its declaration. The verifier does not trust the declaration, and must check that the GPU runs nothing else, such as hidden training.
Off-chip analogue signals, such as power draw, can be measured externally by the verifier. There are two broad approaches to using such signals for compute verification ([13]). In the default approach, the verifier runs labelled examples of permitted and prohibited work on its own chips, including prohibited work disguised by the evasion strategies it anticipates, and fits a classifier to the resulting signals. The classifier is then applied to the operator’s chips. It must transfer from the chips it was fitted on to the chips it monitors, and it is fitted only to the evasions the verifier anticipated. In the alternative approach, which we term the signature check, the verifier, with temporary access to the operator’s hardware, records signatures of permitted workloads. Later, the verifier monitors the chips’ activity and flags any signals that depart from the recorded signatures. This approach needs no examples of prohibited work and no classifier that transfers between chips. It is also harder to evade, because the signals must look specifically like the declared work, rather than merely unlike training. Baker et al. [2] propose a hybrid, in which signatures of permitted work are recorded on the verifier’s own hardware, and so must transfer to the operator’s chips.
Existing empirical studies of verification to identify hidden training have focused on the default approach. Gargiulo & Kulp [4] measure the current drawn by a GPU. A random forest fitted to current traces identifies training from inference and non-AI work with 97% accuracy on model families it has not seen. Similarly, Rahman & Tajdari [12] reach 98% from sliding windows of on-chip telemetry across nine GPU types. Both studies test their classifiers against operators who try to hide training. Detection stays high against most evasion strategies, but falls against some that the classifiers were not fitted to: to 43% for white-box diluted low-rank adaptation in Rahman & Tajdari [12], and to 48–88% for diluted low-rank adaptation in Gargiulo & Kulp [4], though a second test there, which flags each optimiser update, restores detection to at least 98%. We found no empirical study of a signature check built on off-chip signals. Power signatures do identify workloads on high-performance computing systems [3, 10, 6], but those studies assume an operator who does not try to hide work. There are several uncertainties in the signature check [13]: the verifier must choose which chip activity to measure, and how stable signatures stay over time; the verifier must decide how often to investigate an alarm, how finely to define workloads, and whether the chip activity of each workload is specific enough to tell it apart.
In this work we test the signature check on one NVIDIA H200 NVL. A current probe is clamped to the GPU’s auxiliary supply and records 23.4 h of current (§ 2). We record declared work (serving decode, serving prefill and idle), honest training, and several evasion strategies, in particular co-location: training runs as a second process beside the declared inference and uses the capacity that inference leaves spare. We fit classifiers to labelled examples of training to stand for the default approach (§ 2.11). Our signature check is a one-class model fitted only to recordings of the declared work, with its threshold set on separate recordings of that work, so it needs no examples of training or evasion. Together these recordings form its reference. We first test the check with a complete reference (§ 2.8.1). The signature check is only as good as its reference. A declared workload can be missing from the reference, or else an operator can try to corrupt the reference, for example by running training while it is recorded. We therefore test the signature check with an incomplete reference and with the reference corrupted by training (§ 2.9). We also run the signature check continuously over a held-out test day, as a monitor, and ask whether a verifier can tell from its alarms that the reference is incomplete or corrupt. We measure four of the uncertainties listed above (§ 2.10). We close with the lessons for verifiers (§ 3).
Methods
Measurement
Every AI workload is executed by a single H200 NVL hosted by Amodo Design (2026). A Rogowski current probe (Micsig RCP120, 50 mV/A, 34 Hz to 30 MHz) is attached to the GPU’s auxiliary supply. A 16-bit PicoScope 5464E samples the probe at 199,808 S/s, with no anti-alias filter1 and so measures current rather than power.
Threat model
The verifier receives the probe’s trace and the operator’s declaration of work. The verifier also holds pre-recorded current traces (the reference) of the hardware under permitted workloads. The verifier owns and controls the current probe. The operator controls the software on the GPU and cannot physically touch or interfere with the probe. The operator may run any workload, including the adversarial strategies of § 2.3, to hide training. We do not test an adaptive operator that tunes its evasion strategies against the verifier’s detector. We do test the edge case of an operator that corrupts the reference by e.g. running training while the verifier records the declared work (§ 2.9).
Corpus
We use 62 workload runs (23.4 h of current traces).
Earlier studies use shorter recordings; for example Garguilo & Kulp (2026) record 5-s traces at about 10 MS/s, one workload per trace, while Rahman & Tajdari [12] use NVML windows of 5 to 60 s. In practice a verifier may observe a GPU for hours and a single evasion may start and stop inside a recording of declared work, so only continuous recordings let us test detectors as monitors (§ 2.8.1). Every AI workload uses a decoder-only transformer, written in PyTorch, with 8 layers, width 1024, and 168M parameters. The data is open-sourced at Kimpson [7]. The runs fall into the following workload groups:
honest training: full fine-tuning and LoRA. Some full fine-tuning runs add checkpoint evaluation or a copying control, or discard every update;
time-sharing: training and inference alternate in slots;
co-location: training and inference run as two resident processes, and the driver time-slices them. Each run sets a target training share , one run each. At and 0.75 one process pauses between steps to hold the share; we call these runs throttled. At neither process pauses, and the driver alone sets the share. We call this run unthrottled;
jitter, padding and power cap: training with perturbed step timing or a lowered power limit;
declared work, the workloads of the declaration: serving decode (generating tokens), serving prefill (reading prompts) and idle;
non-AI work: dense GEMM, memory-bound kernels and periodic decoys.
Time-sharing, co-location, jitter, padding and power cap are the evasion groups.
The runs are split into three sets, each recorded on different days: for development, for testing, and for calibration. is one day, the test day; is the day after it, and every day before it. Table A1 summarises the runs and traces, factorised by workload group and set.
| Workload | runs | h | windows | runs | h | windows | runs | h | windows |
| honest training | 14 | 4.06 | 2905 | 4 | 0.95 | 680 | 2 | 0.48 | 340 |
| time-sharing | 3 | 0.71 | 510 | 7 | 2.22 | 1586 | – | – | – |
| co-location | 3 | 0.72 | 510 | – | – | – | – | – | – |
| jitter | 4 | 0.95 | 678 | – | – | – | – | – | – |
| padding | 1 | 0.24 | 170 | – | – | – | – | – | – |
| power cap | 2 | 0.48 | 340 | – | – | – | – | – | – |
| declared decode | 2 | 0.48 | 340 | 2 | 0.48 | 340 | 1 | 0.24 | 170 |
| declared prefill | 1 | 0.24 | 170 | – | – | – | – | – | – |
| declared idle | 1 | 0.24 | 170 | 4 | 8.35 | 5994 | 1 | 0.24 | 170 |
| non-AI work | 4 | 0.95 | 681 | 4 | 0.95 | 680 | 2 | 0.48 | 340 |
| total | 35 | 9.06 | 6474 | 21 | 12.94 | 9280 | 6 | 1.43 | 1020 |
Table A1. The corpus per workload and split: runs, scored hours and windows at the window-level hop. Time-sharing on the test day is the embedded episodes of § 2.8.1.
Windows and features
A window is 5 s of trace. The hop between consecutive windows is 5 s for window-level results and 1 s for the monitor. We define a window as training iff it holds at least one complete optimiser step, following Gargiulo & Kulp [4]. Windows with only part of a step are left out of detection rates. Each window gives 25 amplitude-free features of the raw spectrum and of the envelope , the RMS of the raw trace over 2 ms frames. They are adapted from Gargiulo & Kulp [4], who chose them to separate training from inference.
Detectors
Each detector assigns a score to a window . Our detectors follow the two approaches of Scher & Thiergart [13].
The signature check is an isolation forest ([11]). It is fitted to the declared windows of only: decode, prefill and idle. Its score is the negated isolation score, so a high means “unlike the declaration”. It never sees training, evasion or non-AI work.
The classifier is the two-stage random forest of Gargiulo & Kulp [4], with 500 trees per stage (settings in Appendix § 5). The first stage separates AI from non-AI work. The AI-classified work is then passed on to the second stage, which separates training from inference. The classifier stands for the default approach, because it learns from labelled examples of training. Because it is fitted on the GPU it monitors, it is the most favourable case of that approach (§ 2.11). The classifier’s score is
We fit the classifier in three ways:
is fitted to only. So that each evasion is unseen when scored, it is one fit per evasion group, with that group left out, and each group is scored by the fit that never saw it. “The classifier” means ;
the no-evasion fit is with every evasion group removed;
the replica is fitted to 300 traces recorded following the design of Gargiulo & Kulp [4], where it reaches macro-F1 = 0.933 under leave-one-group-out.
and the no-evasion fit are fitted to our corpus, so the declared work is among their examples of work that is not training. The replica is fitted to none of the 62 runs of § 2.3: its traces, each of a single workload, were recorded separately on the same GPU and probe.
Thresholds
A detector flags iff , with
is the empirical quantile, with linear interpolation, and is the declared windows of , one decode run and one idle run of equal length. and every classifier fit use the same rule. For a set of training windows, the detection is . The false-positive rate is with the declared windows of . Every fit of has the same . Its window-level false-positive rates come from the fit without co-location, which has the highest decode false-positive rate of the five.
For , is our choice of rule for what Scher & Thiergart [13] call “sufficiently close to the baseline”. They specify one baseline, whereas we use two separate recordings of declared work: the fit () and the threshold set (). Together they form the reference of . We tested no other rule. We varied only (§ 2.8.1).
Monitor
We run each detector over the test day as a monitor (Figure 1). This represents a verifier that observes the current trace continuously. The verifier does not raise an alarm on a single flagged window. Instead, an alarm starts when 3 of 5 consecutive windows are flagged, and ends after 5 unflagged windows in a row; § 2.8.1 varies this rule. The classifier’s monitor uses the fit without time-sharing, because the test day’s embedded training episodes are time-shared (§ 2.8.1). We describe false alarms by two numbers: , the alarm onsets per monitored hour, and , the fraction of time in alarm.
Figure 1. Three configurations of the signature check on the same test-day recordings. (a) RMS current in three separate recordings: idle, declared decode, and decode with time-shared training episodes (shaded). Line: mean of per 0.25 s; band: its 5–95% range. The dips are unscored seconds. (b)–(d) The score , the threshold (dotted) and the alarm (red bar). (b) The fit holds decode, prefill and idle; the threshold set holds decode and idle. (c) Both hold decode only. (d) The fit holds decode only; the threshold set holds decode and idle. Right column: of honest-training windows from the development data, a positive control.
Results
The check with a complete reference
The signature check needs no examples of hidden training. With the complete reference, whose fit holds decode, prefill and idle, at detects 100% of co-location windows (development data, one run per training share), and at least 99.9% of every other evasion group, although it is fitted to none of them. Its test false-positive rates are 0.6% on decode and 0.1% on idle.
We also run over the test day as a monitor (§ 2.7; Figure 1b). That day embeds 192 time-shared training episodes of 5.1 s to 240 s inside declared inference. An episode is detected iff an alarm is active at some time , where its first step starts at and it ends at . An episode with no alarm is missed, even if it is too short to hold a complete step. We leave out 4 episodes that the recording cuts short. Both and the classifier, , detect all of the other 188. For the median delay from first step to alarm onset is s, and even the shortest episodes (5.1 s) have a within-run lower bound on detection above the target level of 0.5. raises no alarm on test-day decode (Table 2). These episodes test time-sharing only; no co-located episode was recorded.
| Detector | onsets | (/h) | upper (/h) | (%) |
| declared decode, h | ||||
| 0 | 0.0 | 6.3 | 0.0 [0.0, 0.0] | |
| 3 | 6.3 | 16.3 | 1.0 [0.0, 2.0] | |
| idle, h | ||||
| 1 | 0.1 | 0.6 | 0.0 [0.0, 0.1] | |
| 0 | 0.0 | 0.4 | 0.0 [0.0, 0.0] | |
| non-AI busy, h | ||||
| 4 | 4.2 | 9.6 | 99.8 [99.6, 99.9] | |
| 0 | 0.0 | 3.2 | 0.0 [0.0, 0.0] |
Table 2. False alarms on the test day, per background, with exposure . “upper”: the 95% upper bound on , which assumes Poisson onsets. Overlapping windows make onsets correlated, so this bound is approximate. The intervals on come from a block bootstrap (Appendix § 5). The test day holds no declared prefill. Non-AI work is undeclared, so is correct to alarm on it.
These results do not hinge on or on the alarm rule. For from 1% to 10%, detects 100% of co-location windows and all 188 episodes, with 0 false-alarm onsets on test-day decode and at most 4 on idle. Under persistence rules from 2-of-3 to 5-of-5 it still detects all 188 episodes, with at most 2 onsets on decode and 4 on idle.
The check with an incomplete or corrupt reference
The reference is where the signature check can be attacked by an adversarial operator. It is recorded on the operator’s chips, so an operator can try to corrupt it, and even a reference recorded in good faith can erroneously leave out a declared workload.2 The reference has two parts: the fit, and the threshold set that fixes . In § 2.8.1 the fit holds every declared workload, and the threshold set holds decode and idle.
Here we change the reference in three ways (Figure 2b–Figure 2d). Each one makes the check fail, and each failure is one of two kinds. A loud failure raises alarms on declared work, so the verifier sees that the reference is wrong. A silent failure misses hidden training and raises no alarm on declared work, so the verifier sees nothing.
Figure 2. The complete reference (a) and the three changes to it (b–d). Each curve is the distribution of the score for one kind of work: declared work (blue) or hidden training (orange). The monitor flags every window to the right of the threshold (dotted). (a) The fit and the threshold set hold every declared workload. Training is flagged, and declared work is not. (b) One declared workload (dashed) is in neither. It scores high and is flagged: a loud failure. (c) The same workload is in the threshold set but not in the fit. It still scores high, so rises to meet it and passes training. Training is no longer flagged: a silent failure. Training in the threshold set acts the same way. (d) Training is in the fit. Its scores fall below , so the monitor misses it: also a silent failure. Table 1 and Figure 3 hold the measured cases.
A declared workload missing from both parts: loud (Figure 2b, Table 1). Work that is in neither the fit nor the threshold set raises alarms. Prefill held out of both is one case (§ 2.10). A decode-only reference, with decode alone in the threshold set, is another (Figure 1c). It detects 100% of co-location, but it is also in alarm for 99.97% of test-day idle. A monitor that is almost always in alarm on declared idle is useless, but it fails loudly. Its alarms show the verifier that it is failing.
| reference | unlike the fit | in set | co-location (%) | episodes | unlike-fit work flagged (%) | onsets dec. / idle | failure |
| complete reference | – | – | 100.0 | 0 of 188 missed | – | 0 / 1 | none |
| prefill held out of the fit | prefill | none | – | – | prefill 100.0 | – | loud |
| decode-only fit, decode threshold set | prefill, idle | none | 100.0 | 164 of 188 start in alarm | prefill 100.0, idle 100.0 | 2 / 4 | loud |
| decode-only fit, decode + idle threshold set | prefill, idle | idle | 0.0 | 188 of 188 missed | prefill 0.0, idle – | 0 / 0 | silent |
Table 1. The signature check under four references, one per row. “Unlike the fit”: declared work that is not in the fit. “In set”: the part of it that is in the threshold set. Co-location: windows detected at . Episodes: the 188 scored episodes of the test day; “start in alarm” means that an alarm is already on when the episode starts (Appendix A). Flagged: windows of the unlike-fit work above . Onsets: alarm onsets on test-day decode and idle.
A declared workload in the threshold set only: silent (Figure 2c, Table 1). Keep the decode-only fit, and add idle to its threshold set. The threshold set now holds decode and idle, which is our default. Idle is now in the threshold set but not in the fit. It scores high and lifts to 0.786 (Figure 1d; Figure A1 shows the scores). The monitor then detects 0% of co-location and misses all 188 episodes. It raises no alarm on test-day decode, just as the complete reference does. We see that this monitor then fails silently: it does not alert on hidden training, and the verifier has no way to know that it is failing. Prefill is also missing from this fit. Accordingly, with decode alone in the threshold set every prefill window is flagged (Table 1). However now sits above the prefill scores, and so 0% of prefill windows are flagged.
are flagged. That is, a missing workload raises alarms only if nothing else has raised the threshold.
A verifier can expose the silent monitor with a positive control. It gives the monitor work that it knows to be training, and checks that the monitor flags it. The working monitor flags 100% of development honest training. The silent monitor flags 0.17% (Figure 1, right column).
Training in the reference: silent (Figure 2c–d, Figure 3). An operator can also corrupt the reference, by running training while it is recorded. We test this by adding windows of training that runs alone on the GPU (honest training, Section 2.3) to each part of the reference in turn (Appendix B). In both cases the monitor comes to miss hidden training, and it raises no alarm on declared work.
Training in the threshold set raises (see Figure 2c). It takes little training. is the quantile of the threshold set (see Equation (2)), so once training makes up a fraction of that set, sits among the training scores. At , 18 windows added to the 340 calibration windows take detection of the unthrottled run to zero (see Figure 3a). The higher flags declared work less, not more, so the failure is silent. A positive control of honest training does not expose it, because at that share honest training is still flagged at .
Figure 3. Training in the reference blinds . (a) Honest-training windows added to the threshold set, with the fit unchanged and . The unthrottled run drops to zero near a training share of . Honest training is in-sample, since the added windows come from its pool. Test decode and idle are flagged less as rises. (b) Honest-training windows added to the fit, with the threshold set unchanged: median over 20 draws, band from the lowest to the highest draw. Full fine-tuning and LoRA are calibration-day runs, outside every fit. The development declared windows are in every fit (in-sample). The calibration declared windows set , so their rate stays near by construction.
Training in the fit lowers the scores of training (see Figure 2d). The fit learns training as if it were declared work. How much training this takes depends on its kind. With training at 7% of the fit, a full fine-tuning run outside the fit is flagged at 0%. The unthrottled run holds longer. Its median detection reaches 0% at a share of 60% (see Figure 3b). The declared windows of the fit are flagged at 0.6% with a clean fit, and less as training is added, so again no alarm shows the failure. This last result is in-sample, because we did not score held-out declared work under these fits.
The open questions
A verifier who adopts the signature check must still settle four questions raised by [13] (§ 1). Does the signature stay stable over time? How often will the check raise an alarm? How finely must workloads be defined? And is the signature specific enough to separate declared work from hidden work? We answer each in turn from the corpus of § 2.3.
Stability over time. The signature of decode stayed stable over the five days of recording. We recorded decode in 5 runs over 4 sessions, each on a different day. Three runs are in the reference of , two in its fit and one in its threshold set. Across all 5 runs, flags 5 of 850 windows at , and each flagged window is the first window of its run. On the two test-day runs, which are outside the reference, its false-positive rate is 0.6%. Idle was less stable. flags 9% of calibration idle, but only 0.1% of test idle, recorded one day earlier. Because calibration idle scores above decode, it sets , and the false-positive rate on test decode stays well below .
A reference recorded on a single day does not carry over to other days. In an exploratory check, we fitted a reference to 10 windows spread over about four minutes of one decode run, and repeated this for each of 3 runs, one per day. Averaged over the three runs, this reference flags 29% of decode from the other days, against 11% of the rest of its own run. The two runs recorded to one protocol, two days apart, give 22% each way. This reference is not directly comparable to the reference of because it is shorter and flags by a leave-one-out rule rather than . Nevertheless, this check
suggests that the reference should be recorded over several sessions, as the reference of is.
Alarm frequency. The alarm rate sets how often inspectors must investigate. On the test day, declared inference is decode only, and the monitors (§ 2.7) watch h of it (Table 2):
raises no alarm: h (95% upper bound 6.3 h), ;
the classifier, , raises h (upper bound 16.3 h), .
This exposure is short, so these rates bound the alarm rate only loosely. On idle ( h), both monitors stay near zero.
Granularity. The reference must hold each declared workload. When declared prefill is left out of the reference of , flags 100% of it (one development run). This is expected, because prefill is limited by compute and decode by memory bandwidth, so the two load the GPU differently. With prefill in the fit, flags 1 of 170 prefill windows. This rate is in-sample, because neither the calibration day nor the test day holds prefill. One detector, fitted to decode, prefill and idle together, can therefore accept all three. The verifier must record every declared workload, but does not need a separate detector for each. A workload that is in the threshold set but not in the fit instead raises the threshold (§ 2.9).
Specificity. The signature is specific, but by a thin margin. Under the complete reference, declared windows score from 0.39 to 0.68 on , and co-location, honest training and non-AI windows from 0.66 to 0.71 (see Figure A1). The two bands overlap only at the first window of each decode run. The hidden run that comes closest to declared work is the unthrottled co-location run. Its lowest score, 0.658, is 0.017 above 0.641, the upper end of the 95% interval of under a bootstrap of the two calibration runs. With two runs, that end is the threshold that calibration idle alone would set. The signature check also does not fully separate this run from declared decode. Its AUC is 0.994, and 0.6% of test decode windows score above the run’s lowest score.
Figure A1. How scores each workload. Each row shows the per-window scores of one workload and split. Black ticks mark medians, bars the 25–75% range and whiskers the 1–99% range; circles are single windows beyond the whiskers. Windows to the right of (dotted) are flagged. (a) The complete reference, with . It flags every co-location, honest-training and non-AI window. The shaded unthrottled run is the co-location run closest to ; a few decode windows score above it (AUC 0.994). (b) The decode-only fit (Table 1), on a score axis broken at the slashes and widened beyond them. Prefill and idle are outside this fit, and idle now scores high. With idle in the threshold set, and no co-location window is flagged. With decode alone in it, and every co-location window and every idle window is flagged. Each threshold is labelled by its failure, as in Table 1.
Against the default approach
A classifier, like the signature check, works only if its fit covers the declared work. Table 3 sets beside the three classifier fits. It lists what each detector learns from, its detection of the unthrottled co-location run at , and its false-positive rate on test decode.
| detector | declared | honest training | evasions | non-AI | FPR decode | alarm means | |
| replica | pub. | pub. | – | pub. | 0.6% | 0.0% | training |
| no-evasion fit | ✓ | ✓ | – | ✓ | 100.0% | 5.3% | training |
| ✓ | ✓ | ✓ | ✓ | 100.0% | 1.5% | training | |
| ✓ | – | – | – | 100.0% | 0.6% | undeclared |
Table 3. Table 3. The data each detector learns from, its detection of the unthrottled run at , and its false-positive rate on test decode. “pub.”: traces recorded on the same GPU and probe to the published design, not among the 62 runs of § 2.3. An alarm of means “undeclared”; an alarm of a classifier means “training”. The rows for the replica and the no-evasion fit are exploratory.
At its , the classifier, , does nearly as well as . It detects 100% of co-location, and every window of every other group except jitter, where its weakest run is detected at 76%. It stands for the default approach because it learns from examples of training. But it is fitted on the monitored GPU, declared work included, as the signature check is, so it needs no transfer between chips. It is therefore the most favourable case of the default approach. Even without evasion examples, as in the no-evasion fit, a classifier needs examples of honest training, whereas needs only recordings of the declared work.
The threshold of is also fragile. The classifier scores 98.8% of calibration declared windows exactly zero, so . It then flags any window that stage one calls AI and that even one of its 500 stage-two trees votes as training. Small changes in declared work could therefore shift its flags.
A classifier gives no guarantee on a declared workload that its fit has not seen. The replica, fitted to traces recorded to the published design, detects only 0.6% of the unthrottled run at its , and flags 100% of development prefill. , which has development prefill in its fit, flags 4% of it. Gargiulo & Kulp [4] publish two forests fitted to their own corpus: a genuine forest, fitted to their training, inference and non-AI traces, and a hardened forest, which adds their adversarial traces. The two disagree on our windows (Table A2). At their default threshold of 0.5, the hardened forest catches all three co-location runs, but it flags 100% of declared prefill windows as training. The genuine forest flags only 2.4% of prefill, but it misses the unthrottled run (0%). Nothing in either fit tells the verifier which outcome to expect. The replica’s traces differ from ours in workload design and session, so its results do not rank the signature check against the default approach.
| Our windows | G&K hardened | G&K genuine |
| honest training () | 100.0 | 100.0 |
| declared decode | 0.0 | 0.0 |
| declared prefill | 100.0 | 2.4 |
| declared, decode + prefill () | 16.7 | 0.4 |
| co-location, | 100.0 | 100.0 |
| co-location, ) | 100.0 | 0.0 |
| co-location, | 100.0 | 100.0 |
Table A2. Forests fitted by the recipe of Gargiulo & Kulp [4] (G&K) on their corpus, scored on our windows: per cent flagged training. The first rows are a transfer gate (training , declared ). Both forests pass. The hardened forest passes the declared row only because decode outnumbers prefill. Their chain and ours differ in rate and anti-alias filtering, and their own-data check fell short of their reported accuracy (Appendix § 7).
Discussion
The signature check worked when its reference held every declared workload. With no example of hidden training in its fit, flagged every evasion group, and it raised no alarm on test-day decode (§ 2.8.1). When the reference missed a declared workload, the check failed in one of two ways (§ 2.9). A workload missing from both parts of the reference kept the monitor in alarm almost continuously while it ran. This failure was loud, so the verifier could see that something was wrong. A workload in the threshold set but not in the fit raised and blinded the monitor. That monitor raised no more alarms on declared work than the working one, so the failure was silent. Such a workload could also mask a loud failure. Training in the reference also blinded the monitor. So a quiet monitor is no evidence of a working one. The signature check needs no examples of hidden training in its fit, but the verifier still needs them as positive controls, to test that the monitor works.
Acquiring a reference and auditing the monitor. The signature check is only as good as its reference. The reference is recorded on the monitored chip, where the operator controls the work. The verifier must therefore control how it is recorded.
Witness it. Our reference recordings are our own honest runs. A real verifier needs recordings during which the operator cannot train. Both parts of the reference are targets. Training at a share of about in the threshold set takes detection of the unthrottled run to zero, and full fine-tuning at 7% of the fit hides full fine-tuning (§ 2.9).
Span sessions. A reference from one session flags 29% of decode from the other days (§ 2.10).
Test with held-out declared workloads, not only held-out attacks. A declared workload missing from the reference raises alarms (§ 2.10), unless a workload in the threshold set but not in the fit masks it (§ 2.9).
Audit the monitor with positive controls that sit close to the reference. The silent monitor flags 0.17% of honest training, so one control run exposes it. But a monitor that flags a control can still miss other hidden work. At the share of training in the threshold set that hides the unthrottled run, honest training is still flagged (§ 2.9). Honest training sits far from the reference, so it cannot expose a raised threshold. A control must sit as close to the reference as the hidden work it represents.
It is hard to detect anomalous behaviour when permitted behaviour is open-ended ([16]). An agreement can close permitted behaviour off by requiring the operator to declare every workload, so that anything else is an anomaly by rule. Declarations also help verification more broadly; a bound on hidden compute from power draw tightens sharply once the verifier can re-run the declared work (Kimpson et al., [8]), and in simulated datacentre power traces a tracker with its threshold set on declared work detects training hidden in declared inference (Kimpson et al., [9]). The reference then plays the role of the template in warhead verification, where the hard problem is to show that the template item is authentic (Yan & Glaser, [17]). A classifier fitted elsewhere, such as the hardened forest of Gargiulo & Kulp [4], might screen recordings offered as declared work, but that forest also flags 100% of our declared prefill (§ 2.11).
What an alarm means. An alarm from says only that the GPU ran work unlike its declaration. That is, asks “is this declared work?”, rather than “is this training?”. A higher score does not mean the work is more likely to be training. Hidden training, honest training and non-AI work all score from 0.66 to 0.71 (Figure A1), so the score cannot tell them apart. As a monitor it is in alarm for a fraction 0.998 of the time on undeclared non-AI work, where the classifier, , stays silent (Table 2). Nor does an alarm show that a model was trained. The signature check flags every window of a run that discards every update, as it does for training that applies its updates. An alarm therefore works like an anomaly under nuclear safeguards (IAEA, [5], §§11.24–11.26). An alarm alerting does not necessarily mean that the operator has violated the agreement, but it triggers procedures for the verifier to investigate. The operator may have a legitimate reason for the departure, such as an unintentional error or a necessary deviation from the declared workload. The false-alarm rate of the detection method sets the expected frequency of such alerts, and the verifier must consider this when interpreting alarms.
Limits. This work has several limitations.
Scale. We use one model of 168M parameters on one GPU. We do not test one probe on several GPUs at once. Frontier training runs across many GPUs and nodes; Scher & Thiergart [13] envisage the signature check on clusters of many chips. We also look exclusively at current and do not consider other signals such as the communication between chips.
Declared work. Our declared work is the decode, prefill and idle of one model. An operator serving many models under varied load would declare far more, and every declared workload must be in the reference (§ 2.10). We do not test how the reference, or the cost of recording it, grows with the declaration.
Threat model. The evasions did not adapt to the detector. Our corpus lacks diluted low-rank adaptation, the evasion that most reduced detection in earlier studies (§ 1). We test a corrupted reference only in the exploratory checks of § 2.9, with training drawn from our own runs rather than chosen by an adversary. Scher & Thiergart [13], by contrast, assume a well-resourced nation-state that can run arbitrary code to spoof chip activity.
Measurement. Our probe sits on the auxiliary supply and misses the current the GPU draws through its PCIe slot. The digitiser has no anti-alias filter (Appendix § 5). Our chain and that of Gargiulo & Kulp [4] also differ in sample rate, filtering and feature set (Appendix § 7).
Calibration. Our results depend on our split of the reference into a fit and a threshold set (Table 1). One short calibration run each of decode and idle sets (Table A1), and resampling whole calibration runs moves over . Calibration idle is also unlike test idle (§ 2.10).
Exposure. The test day holds no prefill and only 0.475 h of declared decode, so the false-alarm bounds are loose, and declared prefill is a risk we could not measure on held-out data.
Held-out data. We measured detection of hidden training on development data before we scored the test day, so only the false-positive rates and the monitor results are held out.
Acknowledgements
The measurements reported here were collected on an NVIDIA H200 NVL and current-sensing hardware provided by Amodo Design (2026). The author would like to thank Carl Heimann of Amodo Design.
The author thanks the Machine Alignment, Transparency & Security (MATS) programme—its directors, organisers, funders, and staff—who made it possible to work on this project and who provided invaluable resources and support throughout.
Implementation
Channel. A PicoScope 5464E oscilloscope digitises the probe at 16 bits and streams the raw samples at 199,808 S/s. No filter precedes the converter, so current variance above the Nyquist frequency folds into the band. We bound it from bursts recorded at 100 MS/s, assuming no rejection. Under training the folded variance is at most 0.32% of the in-band variance. Under idle, where the current is small, it is at most 13 times the in-band variance. At this bound, both the raw-spectrum and the envelope features of idle windows would mostly describe folded variance. Idle windows help set each detector’s and fit , so a different digitiser or an anti-alias filter could move them; we did not test this. The low rate costs little signal. In the same bursts, 99.3% of a training trace’s variance lies below 20 kHz, and the envelope at our rate matches one sampled ten times faster to within 0.3%.
Corpus. Table A1 counts runs, hours and windows per workload and split.
Detectors. The classifier’s two stages are random forests and the signature check is an isolation forest, all from scikit-learn with 500 trees, default settings otherwise and a fixed seed.
Intervals. For one run, a circular block bootstrap resamples blocks of 12 consecutive windows (60 s), 2,000 times (10,000 for the episode lower bounds and the equivalence test). For two runs it resamples within each run and pools. For three or more it resamples runs. Thresholds stay fixed in every resample. On the monitor, the upper bound on assumes Poisson onsets; the interval on resamples blocks of 10 min. An episode lower bound is the smaller of a one-sided Clopper–Pearson bound and a block bootstrap over blocks of 4 consecutive episodes.
Episodes. An episode that starts while an alarm is active counts as detected only where the run’s flag rate on gap windows, which hold no training, is at most 0.2; we call this the gap guard. A run whose gaps hold no whole window takes the pooled gap flag rate of the other runs. Otherwise only new onsets count, and the result is marked onset-only. The delay is taken over episodes that raise a new alarm. Under the complete reference, 47 of the 188 scored episodes start in alarm, and all are credited (Table 1).
Data and code. The corpus is archived on Zenodo [7]. The analysis code, every committed result, and the scripts that make every figure, table and number in this paper are at https://github.com/tomkimpson/verifying-declared-ai-workloads. The window features are not stored there; scripts/make_windows.py regenerates them from the archive. Every result was computed against corpus commit 73ffebe.
The reference changes in detail
Scores. Figure A1 shows the per-window scores behind the complete reference and the decode-only fit of Table 1.
Training in the threshold set. We add honest-training windows to the 340 calibration windows, with the fit unchanged. Detection of the unthrottled run falls to zero at to 38 for from 1% to 10%, and at for . At that , honest training is still flagged at ; it falls as grows further (Figure 3a).
Training in the fit. We add development honest-training windows, drawn at random, to the 680 declared windows of the fit, with the threshold set unchanged. At (7% of the fit), the calibration-day full fine-tuning run, which is outside every fit, is flagged at 0%, while LoRA stays at 100%. The median detection of the unthrottled run is 35% at and 0% at (60% of the fit). The declared windows of the fit are flagged at 0.6% with a clean fit, and at 0.0% at the largest (median over draws; Figure 3b). These windows are in every fit, so the rate is in-sample.
The cross-check on the corpus of Gargiulo and Kulp
We fetched their 1610 traces ((simgar, 2026)) at a pinned revision, checked each file’s hash, and resampled from 9.765625 MS/s to 200 kS/s with an exact rational resampler and its anti-alias filter. We extracted our 25 features and fitted their two forests: genuine, on their training, inference and non-AI traces; hardened, adding their adversarial traces.
On their own traces, under their grouped five-fold protocol, our measurement chain reaches macro- 0.891 (range 0.845 to 0.945) and accuracy 0.908. They report 0.955 and 0.97 with 30 features at the full rate. We did not reach their accuracy, and scored our windows anyway. Shuffled labels give 0.306. Their traces pass an anti-alias filter on decimation and ours do not, so features above about 10 kHz differ between the datasets.
The published hardened forest. Gargiulo & Kulp [4] harden their forest on four evasion strategies of their own. We scored our windows with both forests (Table A2). At their default threshold of 0.5, their genuine forest misses the unthrottled run (0%). Their hardened forest catches all three co-location runs, but it also flags 100% of declared prefill windows as training. Their hardening works here. Its cost falls on a declared workload that our calibration day does not hold.
References
- [2]Baker, M., Kulp, G., Marks, O., Brundage, M., and Heim, L. Verifying international agreements on AI: Six layers of verification for rules on large-scale AI development and deployment, 2025. URL https://arxiv.org/abs/2507.15916.
- [3]Copos, B. and Peisert, S. Catch me if you can: Using power analysis to identify HPC activity, 2020. URL https://arxiv.org/abs/2005.03135.
- [4]Gargiulo, S. and Kulp, G. Workload identification with physical side channels for AI governance, 2026. URL https://arxiv.org/abs/2609.00309.
- [5]IAEA. IAEA Safeguards Glossary, 2022 Edition. Number 3 (Rev. 1) in International Nuclear Verification Series. International Atomic Energy Agency, Vienna, 2022. ISBN 978-92-0-122222-0. URL https://www-pub.iaea.org/MTCD/Publications/PDF/PUB2003_web.pdf.
- [6]Karimi, A. M., Sattar, N. S., Shin, W., and Wang, F. Profiling and modeling of power characteristics of leadership-scale HPC system workloads, 2024. URL https://arxiv.org/abs/2402.00729.
- [7]Kimpson, T. NVIDIA H200 NVL current traces of GPU training, inference and non-AI workloads, with training episodes hidden in declared serving. Zenodo dataset, version 1.0.0, 2026. URL https://zenodo.org/records/23521636.DOI
- [8]Kimpson, T., Baker, M., and Graham, E. Can power draw constrain covert compute? limits of analogue verification for AI governance, 2026a. URL https://arxiv.org/abs/2610.07476.
- [9]Kimpson, T., Baker, M., and Graham, E. Detecting AI training in datacentre power, 2026b. URL https://arxiv.org/abs/2610.30182.
- [10]Köhler, S., Wenzel, L., Plauth, M., Boning, P., Gampe, P., Geier, L., and Polze, A. Recognizing HPC workloads based on power draw signatures. In 2021 Ninth International Symposium on Computing and Networking Workshops (CANDARW), pp. 278–284. IEEE, 2021. doi: 10.1109/CANDARW53999.2021.00053.DOI
- [11]Liu, F. T., Ting, K. M., and Zhou, Z.-H. Isolation forest. In 2008 Eighth IEEE International Conference on Data Mining, pp. 413–422, 2008. doi: 10.1109/ICDM.2008.17.DOI
- [13]Scher, A. and Thiergart, L. Mechanisms to verify international agreements about AI development, 2025. URL https://arxiv.org/abs/2506.15867. Report dated November 2024.
- [14]Shavit, Y. What does it take to catch a Chinchilla? Verifying rules on large-scale neural network training via compute monitoring, 2023. URL https://arxiv.org/abs/2303.11341.
- [16]Sommer, R. and Paxson, V. Outside the closed world: On using machine learning for network intrusion detection. In 2010 IEEE Symposium on Security and Privacy, pp. 305–316, 2010. doi: 10.1109/SP.2010.25.DOI
- [17]Yan, J. and Glaser, A. Nuclear warhead verification: A review of attribute and template systems. Science & Global Security, 23(3):157–170, 2015. doi: 10.1080/089298282.2015.1087221.DOI