Clinically Informed Colour Encoding Improves the Localisation and Stability of Explanations in Deep Learning ECG Models: External Validation in a UK Biobank Epilepsy Cohort
Abstract
Objective: It is not known whether the input representation governs the quality of explanations of deep learning models for electrocardiogram analysis. Risk of dangerous ventricular repolarisation is judged from the QT-interval and the shape of the T-wave, features that are hard to assess visually and harder still to verify in a model's reasoning. We evaluate a pseudo-colour encoding filling the area beneath the QT interval, its colour sequence designed from clinical electrophysiology knowledge and mapped to a validated risk prediction model, the QT-nomogram. Methods: Two identically configured residual networks were trained on single-heartbeat images from a clinical trial, differing only in whether pseudo-colour encoding was applied, so that any difference is attributable to the chromatic channel alone. To externally validate the effect, both models were applied without fine-tuning or threshold tuning to a previously unseen epilepsy cohort from the UK-Biobank at two visits, and eight explanation methods compared on faithfulness, localisation and stability. Results: The pseudo-colour model achieved areas under the receiver operating characteristic curve of 0.903 and 0.914 at the first and follow-up visits, against 0.719 and 0.720 for the monochrome model, recovering three to five times as many at-risk heartbeats at comparable specificity. Pseudo-colour encoding improved explanation localisation and stability for almost every method, and the improvement reproduced across both visits. Conclusion: The input representation is a controllable and previously overlooked determinant of both predictive performance and explanation quality. Significance: Treating interpretability as a representation-design problem offers a route towards explanations clinicians can check against known electrophysiology.
This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may no longer be accessible.
This research was conducted using the UK Biobank Resource under Application Number 179597. Access to UK Biobank data was funded through The University of Manchester, with Newcastle University as a project partner.
E-mails: [email protected]; [email protected]; [email protected]; [email protected].
Introduction
Ventricular depolarisation and repolarisation electrical activity appears on the surface electrocardiogram (ECG) as the interval from QRS onset to T-wave offset, known clinically as the QT interval. Prolongation of this interval reflects delayed repolarisation, which increases dispersion of repolarisation across the ventricular wall and thus the substrate for re-entrant fatal arrhythmia, of which Torsades de Pointes (TdP) is the most consequential form [1, 2].
Duration alone, however, discriminates risk poorly [2]. Selective blockade of the rapid delayed rectifier potassium current prolongs repolarisation and increases transmural dispersion, whereas agents additionally inhibiting late sodium or calcium currents prolong the interval while suppressing the arrhythmic substrate [3]. The discriminating information resides substantially in T-wave morphology rather than QT-interval length [3, 4, 5].
This matters for populations in whom repolarisation abnormality is common and hard to assess. Sudden unexpected death accounts for a substantial share of epilepsy-related mortality [6], and a proportion of patients exhibit cardiac electrical abnormality including prolonged repolarisation [6, 7]; a pathogenic link between congenital long QT syndrome and seizure-like presentation has been reported [8]. Epilepsy ECGs are also noisier and more heterogeneous, making them a demanding test of any automated method.
Deep learning performs strongly on ECG tasks [9, 10] but its opacity limits adoption in safety-critical settings [11]. Explanations, however, are not automatically trustworthy: attribution maps are unstable even across models of identical architecture, and there is no guarantee they land on structures a clinician would recognise as relevant [12].
Morphology, however, resists the kind of verification that a duration measurement permits. An interval can be checked against a threshold; a shape cannot, and clinicians themselves disagree in assessing it. A deep learning model that predicts repolarisation risk accurately is therefore useful only if its reasoning can be inspected — and that inspection is only as good as the explanation it rests on. This paper asks whether the representation in which the electrocardiogram is presented to the network determines the quality of that explanation.
Representation as an Interpretability Lever
Encoding one-dimensional signals as images to exploit pretrained vision architectures is established practice: Gramian angular fields, Markov transition fields and recurrence plots have all been used this way [13, 14], and explanation methods have been applied to such encodings as an inspection tool. Complementary work argues the time domain is not always the most informative domain in which to express an explanation, and constructs saliency in transformed domains while holding the model fixed [15]. Sanity-check studies further show that input structure propagates into attribution maps and that function smoothness affects saliency quality [16].
To our knowledge the input encoding has not been treated as a controlled experimental variable with explanation quality as the dependent measure. Existing comparisons between imaging transforms confound encoding with geometry: a recurrence plot and a Gramian field differ in spatial structure, information content and encoding simultaneously, so differences in attribution cannot be attributed to any one. The present design avoids this. Both representations are the same waveform rendering at the same scale and position; only the chromatic channel differs. Pseudo-colouring has been shown to enable lay observers to detect prolonged repolarisation regardless of heart rate [17], and, in the work immediately preceding this study, to improve few-shot learning and produce clinically aligned explanations on the ECGRDVQ dataset [18]. That work established the effect using a single explanation method, evaluated qualitatively and without validation beyond the source dataset. The present work evaluates eight explanation methods against three quantitative criteria and tests transfer to an unseen clinical UK Biobank cohort at two separate visits.
We therefore (i) isolate the input representation as a determinant of explanation quality using a matched-pair design; (ii) evaluate eight explanation methods against three quantitative criteria rather than by inspection; (iii) validate externally on an unseen epilepsy cohort; and (iv) propose a mechanistic account of why chromatic encoding aids attribution, deriving a testable hypothesis about which component of repolarisation the model attends to.
Methods
Datasets
For training, we used the ECGRDVQ (Electrocardiogram Ranolazine, Dofetilide, Verapamil, Quinidine) database, which is a publicly available clinical trial dataset comprising 5,235 12-lead ECG recordings from 22 healthy volunteers in a randomised crossover study of four QT-prolonging drugs vs placebo with differing ion-channel profiles [3, 19]. It was designed to demonstrate that interval duration alone discriminates torsadogenic risk poorly, and so spans a controlled range of repolarisation morphologies of known pharmacological origin. Intervals were measured by expert cardiologists and risk labels assigned by the QT nomogram [20], giving 180 at-risk of TdP and 4,870 not-at-risk ECG recordings using lead II. Only one beat was retained per 10-second ECG recording and all others discarded, so no two training images share a trace. No augmentation was applied.
For external validation, 12-lead resting ECG recordings (also using lead II) from participants with epilepsy were extracted from the UK Biobank [21] and used exclusively for external evaluation. Epilepsy was ascertained using First Occurrences fields (field identifiers 131048 and 131050), which record the earliest reported instance of a diagnosis mapped to ICD-10 codes G40 (epilepsy) and G41 (status epilepticus). Participants carrying either code and having an available electrocardiogram were included.
The 12-lead ECG is acquired at the imaging first visit (instance 2) and the repeat imaging follow-up visit (instance 3); both were analysed, and are reported separately throughout.
Recordings were excluded where heart rate fell outside 40–100 bpm or where heart rate or the QT-interval ground truth values supplied by UK Biobank were missing. The heart-rate range corresponds to that spanned by the training data (40–96 bpm in ECGRDVQ), so evaluation is restricted to the regime in which the colour mapping was calibrated and over which the QT-nomogram assigns risk reliably. After exclusion, instance 2 comprised 873 participants (17 at risk of Torsades de Pointes (TdP) based on the QT-nomogram, 856 not at risk) and instance 3 comprised 168 participants (7 at risk, 161 not at risk).
All heartbeats within each 10-second trace were retained at test time for external validation, giving 8,217 single-heartbeat images at instance 2 (125 at risk, 8,092 not at risk) and 1,561 at instance 3 (49 at risk, 1,512 not at risk). Beat-level labelling is appropriate because repolarisation duration can vary between beats within a recording.
The resulting prevalence (≈ 1.5% of beats at instance 2) differs by more than an order of magnitude from that of the training data (≈ 27:1), as do acquisition conditions: ECGRDVQ was recorded under controlled research conditions in healthy volunteers, whereas the epilepsy cohort reflects routine clinical acquisition. The low TdP event rate is clinically realistic for dangerous repolarisation prolongation and is retained rather than corrected.
Input Representations
Each beat was rendered twice (Figure 1). The standard representation is a conventional monochrome ECG trace on a gridded background. The pseudo-colour representation fills the area beneath the QT interval, spanning the whole of ventricular repolarisation including the T-wave and, where present, the U-wave. The colour sequence is mapped according to the QT-nomogram [20], a clinically validated risk model, and is adjusted automatically to heart rate, so that the position of the waveform relative to the nomogram boundary is expressed chromatically [17]. The transform acts on the rendering and leaves the underlying signal unchanged; the two images are identical in geometry, scale and position, differing only in the chromatic channel. The encoding is a deliberate injection of clinical prior knowledge into the input space. Rather than training an opaque model and explaining it afterwards, interpretability is embedded in the representation itself, so that human and machine reason over the same perceptually structured features [18].

Figure 1. Standard (left) and pseudo-colour (right) renderings of the same beat, from a recording with prolonged ECG (bottom, HR = 45 and QT = 504ms), and normal ECG (top, HR =56 and QT=438ms). Geometry, scale and position are preserved exactly. Both have a sampling rate of 500 Hz, providing a resolution of 2 milliseconds per sample, making it difficult to perceive the risk visually without the colour (about a 66 ms subtle difference).
Colour is a pre-attentive visual property, and mapping a temporally distributed quantity onto it renders visible a feature that is otherwise difficult to judge by eye [17]. Predictive performance under this representation should therefore be understood as the model exploiting encoded clinical knowledge rather than discovering repolarisation risk independently. Critically, however, the colour gradient spans the entire repolarisation area and does not specify where within that area diagnostic weight should fall; the distribution of attribution between early and late repolarisation remains free, and is the subject of the explanation analysis reported below.
Why Encoding Should Affect Attribution
A colour map adds no information: it is a deterministic function of the signal already present. Any effect must therefore arise from how the representation interacts with the network, not from what it encodes.
Two mechanisms are plausible. First, the classifier is initialised from ImageNet weights, whose early filters encode colour-opponent and textured natural-image statistics. A thin dark trace on a white ground lies far outside that distribution and activates few pretrained filters, whereas a chromatically encoded waveform lies closer to the manifold on which they were learned. Second, and consequently, attribution is computed on a different function. Gradient methods consume the local derivative of the output with respect to the input; perturbation methods consume the response surface under occlusion. Redistributing a single-channel amplitude signal across three chromatic channels yields denser, better-conditioned gradients where a monochrome trace is locally flat. This is consistent with evidence that input structure propagates into attribution maps and that function smoothness governs saliency quality [16].
This account predicts that a monochrome trace replicated across three channels should behave like the standard arm, whereas an arbitrary colour map with no clinical design should recover part but not all of the benefit — distinguishing it from the alternative account, that the benefit arises specifically from clinical design.
Model, Training and Explanation Methods
Both models use a ResNet-18 backbone from ImageNet weights [22], with conv1–layer2 frozen to retain transferable visual features [23] and layer3–layer4 fine-tuned. The head was replaced with a binary classifier preceded by dropout (). Training used Adam (), batch size 32, step decay (step 5, ) and cross-entropy loss for 30 epochs on the complete ECGRDVQ dataset, with no internal validation split and no early stopping. Images were resized to 224×224 and normalised with ImageNet statistics. The two runs were identical in architecture, hyperparameters, data and random seed, differing only in representation; determinism was enforced throughout by seed fixing, deterministic kernels and disabled cuDNN benchmarking. Trained models were applied to the epilepsy cohort without fine-tuning or domain adaptation for external validation.
Eight explanation methods were applied to both models using Captum [24]: Saliency, Guided Backpropagation, Integrated Gradients (blurred-waveform baseline), GradientShap, DeepLIFT with NoiseTunnel, layer-wise relevance propagation (LRP) and Grad-CAM (gradient family) and Occlusion (perturbation). Attention methods were excluded as they require architectural change rather than post-hoc explanation of the same model, and attention weights are not reliably faithful [25]. Explanations were computed for every at-risk beat at both visits (125 beats from 17 participants at instance 2; 49 from seven participants at instance 3), with both representations evaluated on the same beats to permit paired comparison. LIME was not included, its stochastic sampling and superpixel segmentation placing it on a different scale from the methods above and rendering it sensitive to the chromatic difference under test.
Evaluation Protocol
Discrimination is reported by the area under the receiver operating characteristic curve (AUC-ROC), which is independent of any decision threshold. Threshold-dependent metrics are reported at the default operating point of 0.5; no threshold tuning was performed, so no information from the evaluation cohorts entered the choice of operating point. Balanced accuracy, the mean of sensitivity and specificity, is reported in preference to raw accuracy, which at the prevalence observed here is dominated by the majority class. Positive predictive value is similarly governed principally by the base rate rather than by model behaviour and is not reported.
Beats are clustered within participants, so the effective sample size approaches the participant count rather than the beat count. Confidence intervals were therefore obtained by bootstrap resampling of participants, with both models rescored on each resample so that the interval on the between-representation difference is itself paired.
Explanation Quality Metrics
Faithfulness measures whether an explanation reflects the model’s actual decisionmaking. It was assessed by perturbing ECG regions identified as important and measuring the resulting change in predicted QT risk score. Larger decreases in the score indicate that the perturbed region was genuinely influential, meaning the explanation successfully captured clinically aligned waveform features the model relies on [26].
Localisation evaluates how well explanations focus on the masked QT region. The mask provides a simple baseline [27] but only approximates QT morphology, so localisation results should be interpreted as alignment with general waveform structure rather than precise QT-specific or clinically verified localisation.
Stability measures how consistent an explanation is under small input perturbations. Gradient-based stability was computed using cosine similarity between repeated attributions [28]. More stable explanations are more reliable for clinical interpretation because they reflect genuine model behaviour rather than noise [29].
Confidence intervals were obtained by non-parametric cluster bootstrap: participants were resampled with replacement, all beats from each selected participant retained, and the median recomputed, with intervals taken as the 2.5th and 97.5th percentiles of 5,000 resamples. Resampling at the participant rather than beat level accounts for the correlation between beats from the same individual, which materially widens the intervals for faithfulness.
Results
Discrimination Under Domain Shift
Applied without fine-tuning or threshold tuning to the epilepsy cohort, the pseudo-colour model achieved an AUC-ROC of 0.903 at instance 2 and 0.914 at instance 3, against 0.719 and 0.720 for the monochrome model (Table I). The advantage of chromatic encoding was therefore approximately 0.19 in AUC-ROC and was reproduced almost exactly across the two visits.
| Instance 2 | Instance 3 | |||
| Total participants at TdP risk | 873 | 168 | ||
| 17 | 7 | |||
| Heartbeat images at TdP risk | 8,217 | 1,561 | ||
| 125 | 49 | |||
| Colour | Mono. | Colour | Mono. | |
| AUC-ROC | 0.903 | 0.719 | 0.914 | 0.720 |
| Sensitivity | 68.0% | 18.4% | 67.3% | 14.3% |
| Specificity | 87.9% | 90.6% | 89.6% | 90.8% |
| Balanced accuracy | 78.0% | 54.5% | 78.5% | 52.5% |
Table I. External evaluation on the UK Biobank epilepsy cohort at the default operating point, with no threshold tuning. Instance 2 is the first imaging visit and instance 3 the repeat imaging follow-up visit; the latter comprises largely the same participants and is reported as a repeated measurement. Positive predictive value is governed by the base rate at this prevalence and is not reported.
The two representations differed asymmetrically in the two error types. Specificity was closely comparable between them at both visits (87.9% against 90.6% at instance 2; 89.6% against 90.8% at instance 3), whereas sensitivity differed by roughly fifty percentage points (68.0% against 18.4%; 67.3% against 14.3%). At effectively matched false-positive rates, the pseudo-colour representation therefore recovered between three and five times as many at-risk beats: 85 of 125 against 23 at instance 2, and 33 of 49 against 7 at instance 3. The difference is not an artefact of the operating point, since
the monochrome receiver operating characteristic curve rises shallowly across its full range rather than crossing the pseudo-colour curve.
Raw accuracy was equivalent between representations at both visits (88–89%), which at this prevalence reflects the majority class rather than model behaviour: the monochrome model attains it while failing to identify 102 of 125 at-risk beats. Balanced accuracy, which weights the two classes equally, separates the representations clearly (78.0% against 54.5% at instance 2; 78.5% against 52.5% at instance 3) and places the monochrome model only marginally above chance.
Performance was closely comparable across the two instances for both representations, differing by 0.011 and 0.001 in AUC-ROC respectively. Because instance 3 comprises largely the same participants reassessed some years later, this consistency is best read as stability of model output within individuals over time rather than as independent replication. The instance 3 estimates rest on 49 at-risk beats from seven participants and are correspondingly imprecise.
At a beat-level prevalence of 1.5%, the default operating point yields 983 false positives against 85 true positives for the pseudo-colour model at instance 2. This ratio follows from the base rate rather than from model behaviour, and is the reason threshold-free discrimination is reported as the primary measure. For a screening application in which flagged recordings would receive expert review rather than intervention, a high false-positive rate at high sensitivity may be an acceptable trade; the appropriate operating point is a deployment decision that this evaluation does not attempt to fix.
At a beat-level prevalence of 1.5%, the default operating point yields 983 false positives against 85 true positives at instance 2. This ratio follows from the base rate rather than from model behaviour, and is the reason threshold-free discrimination is reported as the primary measure. For a screening application in which flagged recordings would receive expert review rather than intervention, a high false-positive rate at high sensitivity may be an acceptable trade; the appropriate operating point is a deployment decision that this evaluation does not attempt to fix.
Explanation Quality
Explanation metrics were computed for every at-risk beat at both visits (125 beats from 17 participants at instance 2; 49 beats from seven participants at instance 3), with both representations evaluated on the same beats so that all comparisons are paired (Table II).
Localisation was higher under pseudo-colour for seven of the eight methods at instance 2 and for all eight at instance 3, with the gain reaching +0.115 for Saliency and +0.109 for Integrated Gradients. LRP was the sole exception, localising better under the monochrome representation at instance 2 (−0.089) but not at instance 3.
Stability was higher under pseudo-colour for every method at both visits. Gains were largest for the gradient family — Guided Backpropagation +0.185, Saliency +0.179, DeepLIFT +0.166 at instance 2 — and negligible for Occlusion and Grad-CAM, which are near-deterministic under both representations by construction. LRP was unstable under both (median throughout), indicating inconsistency arising from the method rather than from the input.
Faithfulness was higher under pseudo-colour for every method at both visits, and the differences were large: median 0.62 against −0.12 for Guided Backpropagation and 0.82 against −0.63 for Occlusion at instance 2. All differences survived correction ().
Replication Across Visits
The between-representation differences reproduced closely at the two visits despite involving different participants, different beats and recording sessions separated by several years. Localisation differences agreed to within 0.02 for seven of eight methods and reproduced to three decimal places for Guided Backpropagation (+0.092 at both visits) and GradientShap (+0.037 at both); stability differences agreed to within 0.01 for every method. Absolute values were similarly consistent: under pseudo-colour, localisation differed between visits by at most 0.017 and stability by at most 0.006 across all eight methods.
Two method-level failures likewise reproduced. Grad-CAM achieved a median faithfulness of 0.003 at both visits, indicating that its attributions carry essentially no information about the model’s dependence on the input at this resolution; computing attribution from a coarse final feature map upsampled to input resolution is poorly suited to a thin rendered waveform. LRP achieved a median stability of 0.006 and 0.010, so its localisation values should not be interpreted.
Faithfulness Tracks Prediction Outcome
The faithfulness differences require qualification. Within the pseudo-colour arm, faithfulness separated sharply according to whether the model classified the beat correctly: at instance 2 the median for correctly flagged beats was 0.698 against −0.092 for missed beats under Guided Backpropagation, with comparable separation for every gradient method (). The relationship was graded rather than binary, faithfulness correlating with the predicted at-risk probability at Spearman –0.96 across methods.
Because the monochrome model has low sensitivity and flagged far fewer at-risk beats than the pseudo-colour model (23 of 125 against 85 at instance 2; seven of 49 against 33 at instance 3), much of the apparent faithfulness advantage follows from this difference in detection rather than from a property of the explanations themselves. Restricting the comparison to the 20 beats that both models classified correctly, the localisation and stability advantages persisted for six of seven methods (), whereas the faithfulness advantage did not, reversing in direction for Integrated Gradients, Saliency and GradientShap. We therefore regard localisation and stability as properties of the representation, and the faithfulness difference as substantially a consequence of the pseudo-colour model detecting cases that the monochrome model misses.
Qualitative Explanations
Representative explanations for a correctly classified at-risk beat are shown in Figure 2. GradientShap attributes to the repolarisation region under both representations but with low visual contrast. Occlusion disperses attribution across regions without diagnostic content under the standard representation and concentrates on the repolarisation segment under pseudo-colour. Being drawn from individual beats, these observations are illustrative rather than evidential.

Figure 2. Explanations for a correctly classified at-risk heartbeat under the pseudo-colour (top) and monochrome (bottom) representations, shown for GradientShap, Occlusion and LIME. The leftmost panel of each row shows the input: under pseudo-colour, the fill beneath the QT interval extends into the warm end of the sequence, indicating a repolarisation duration approaching the nomogram threshold. GradientShap attributes to the repolarisation segment under both representations but with low contrast against the surrounding waveform. Occlusion shows the clearest difference: attribution forms a compact region over the T wave under pseudo-colour, whereas under monochrome it spreads across a wider area extending into segments without diagnostic content.
Discussion
The representation in which a physiological signal is presented to a network is a controllable determinant both of predictive performance and of the quality of the explanations subsequently extracted from it. Chromatic encoding of the repolarisation interval raised discrimination by approximately 0.19 in AUC-ROC and improved the localisation and stability of attribution for almost every explanation method examined. Because the two representations are identical in geometry, scale and position, these differences are attributable to the chromatic channel rather than to confounded changes in spatial structure — a control that comparisons between imaging transforms cannot achieve.
The most substantial evidence is the replication. Effect sizes for the between-representation difference reproduced across two visits involving different participants, different beats and recording sessions separated by years, agreeing to within 0.02 for localisation and 0.01 for stability, and in two cases to three decimal places. Explanation quality under this representation is therefore a stable property of the pairing of method with representation rather than an artefact of a particular sample.
The results also identify two method-level failures that reproduced at both visits. Grad-CAM produced attributions with essentially no faithfulness in this setting, and LRP produced attributions with essentially no stability. Neither is a limitation of the encoding; both indicate that method selection for rendered physiological signals cannot be assumed from performance on natural images. Guided Backpropagation and GradientShap performed best overall, combining high localisation with high stability under pseudo-colour.
| Method | Localisation Instance 2 Col. | Localisation Instance 2 Mono | Localisation Instance 3 Col. | Localisation Instance 3 Mono | Stability Instance 2 Col. | Stability Instance 2 Mono | Stability Instance 3 Col. | Stability Instance 3 Mono | Faithfulness Instance 2 Col. | Faithfulness Instance 2 Mono | Faithfulness Instance 3 Col. | Faithfulness Instance 3 Mono |
| Guided Backprop | 0.897 | 0.805 | 0.911 | 0.819 | 0.985 | 0.800 | 0.986 | 0.791 | 0.617 | −0.116 | 0.685 | −0.164 |
| Integrated Grad. | 0.801 | 0.692 | 0.800 | 0.699 | 0.739 | 0.601 | 0.742 | 0.602 | 0.628 | 0.014 | 0.616 | 0.027 |
| DeepLIFT | 0.700 | 0.634 | 0.706 | 0.635 | 0.741 | 0.575 | 0.746 | 0.586 | 0.591 | −0.146 | 0.639 | −0.154 |
| Saliency | 0.809 | 0.695 | 0.798 | 0.701 | 0.704 | 0.525 | 0.710 | 0.526 | 0.626 | 0.023 | 0.635 | 0.041 |
| GradientShap | 0.905 | 0.867 | 0.918 | 0.881 | 0.921 | 0.813 | 0.923 | 0.818 | 0.620 | −0.048 | 0.631 | −0.028 |
| Occlusion | 0.804 | 0.746 | 0.830 | 0.746 | 0.999 | 0.993 | 0.999 | 0.992 | 0.818 | −0.630 | 0.875 | −0.594 |
| Grad-CAM | 0.693 | 0.673 | 0.710† | 0.683 | 0.999 | 0.996 | 1.000 | 0.996 | 0.003 | 0.000 | 0.003 | 0.000 |
| LRP | 0.736 | 0.825 | 0.792† | 0.778 | 0.006† | 0.008 | 0.010† | 0.008 | 0.517 | −0.190 | 0.504 | −0.165 |
Table 2. Explanation quality by method, representation and visit, for at-risk beats. Values are medians; all colour–monochrome differences are significant at after Benjamini–Hochberg correction across methods except those marked †. Both representations were evaluated on the same beats, so comparisons are paired.
Physiological Interpretation and Hypothesis
Risk labels in both cohorts derive from the QT nomogram, a criterion defined on interval duration against heart rate; no component of the training signal encodes T-wave shape. Attribution under pseudo-colour nonetheless concentrated on the repolarisation segment rather than distributing across the full depolarisation–repolarisation complex.
This is of interest given the provenance of the training data. ECGRDVQ was constructed to show that duration alone discriminates torsadogenic risk poorly: selective potassium-current blockade prolongs late repolarisation and increases transmural dispersion, whereas multichannel blockade prolongs the interval while suppressing the arrhythmic substrate [3]. The discriminating information resides in terminal T-wave morphology, conventionally quantified from T-wave peak to T-wave offset.
That attribution should favour this region, under a label not referencing it, suggests the network may have acquired a morphological correlate of repolarisation abnormality rather than an implicit interval measurement.
We state this as a hypothesis. The explanation sample is small; the mask approximates waveform structure rather than delineated boundaries; and the colour map was designed to emphasise T-wave morphology, so attribution there may partly reflect the encoding. Three analyses would discriminate these accounts: recomputing localisation against masks from automated delineation of QRS onset, T peak and T offset, permitting early and late repolarisation to be quantified separately; substituting an arbitrary colour map, which should degrade T-wave attribution if the effect is knowledge-driven; and stratifying attribution by administered agent within ECGRDVQ, testing whether selective and multichannel blockers produce distinguishable late-repolarisation signatures.

Figure 3. Explanations for a correctly classified not-at-risk heartbeat, arranged as in Figure 2. The pseudo-colour input (top left) shows the fill terminating within the cool end of the sequence, consistent with a repolarisation duration well below the nomogram threshold. The pattern seen for the at-risk case is reproduced here in the not-at-risk case: GradientShap is diffuse under both representations; Occlusion concentrates over the T wave under pseudo-colour and disperses under monochrome; and LIME resolves a single region under pseudo-colour against fragmented attribution under monochrome. That the same contrast holds for a beat the model assigns to the low-risk class indicates the effect is a property of the representation rather than of the predicted class.
In the epilepsy UK Biobank cohort, repolarisation abnormality may reflect autonomic modulation, chronic antiseizure medication exposure, or shared ion-channel pathology between neuronal and cardiac tissue — the last consistent with seizure-like presentation among genotyped long QT patients [8]. Attribution-based analysis of a cohort with concurrent electroencephalography and genotyping would offer a route to separating these, and is the natural extension towards brain–heart interaction.
Interpretation, Limitations and Scope
The same encoding improves detection of prolonged repolarisation by observers without cardiology training [17] and, as shown here, the stability and localisation of machine attribution. A representation built from clinical knowledge of where diagnostic information resides thus aids both human and machine interpretation — which is what makes explanations in image space checkable, the attribution being expressed over the same visual features a clinician already uses. This motivates rendering rather than modelling the raw signal: the colour encoding has no direct analogue in signal space, clinical ECG interpretation is itself visual, and image space permits transfer from large-scale pretraining, material given 22 training individuals. Encodings such as recurrence plots, though also image-based, would forfeit that clinical readability.
Limitations bear on interpretation. The pseudo-colour encoding embeds the nomogram criterion from which the risk labels derive, so discrimination under that representation demonstrates effective use of injected clinical knowledge rather than independent discovery of repolarisation morphology; the substantive result here concerns where attribution falls within the encoded region. Training used 22 individuals (5,235 ECGs), so the learned representation may not span clinical morphological variation. At the observed prevalence the default operating point yields many false positives per true positive, and no operating point is proposed for deployment. The explanation analysis rests on at-risk beats from 17 and 7 participants respectively, so effective sample size is closer to the participant than the beat count; confidence intervals were computed accordingly. The localisation mask approximates waveform structure rather than delineated repolarisation boundaries. Finally, a colour-dependent representation raises questions of accessibility for observers with colour-vision deficiency and of fidelity under monochrome reproduction, neither assessed here.
Conclusion
Explanation quality in deep learning models of physiological signals depends not only on the explanation method but on the representation in which the signal is presented. Using a matched-pair design isolating the chromatic channel, we find that clinically informed colour encoding improves the stability of gradient-based attribution, modestly improves localisation, reduces catastrophic explanation failure, and preserves discrimination and probability calibration under domain shift better than conventional monochrome rendering. Treating interpretability as a problem of representation design offers a route towards explanations clinicians can verify against established electrophysiology and can have wider applications beyond QT-prolongation.
References
- [1]Y. G. Yap and A. J. Camm, “Drug induced qt prolongation and torsades de pointes,” Heart, vol. 89, no. 11, pp. 1363–1372, 2003.pubmed.ncbi.nlm.nih.gov/14594906
- [2]P. J. Schwartz and R. L. Woosley, “Predicting the unpredictable: drug-induced qt prolongation and torsades de pointes,” Journal of the American College of Cardiology, vol. 67, no. 13, pp. 1639–1650, 2016.DOI
- [3]L. Johannesen, J. Vicente, J. W. Mason, C. Sanabria, K. Waite-Labott, M. Hong, P. Guo, J. Lin, J. S. Sørensen, L. Galeotti et al., “Differentiating drug-induced multichannel block on the electrocardiogram: randomized study of dofetilide, quinidine, ranolazine, and verapamil,” Clinical Pharmacology & Therapeutics, vol. 96, no. 5, pp. 549–558, 2014.DOI
- [4]T. A. Bhuiyan, C. Graff, J. K. Kanters, J. Melgaard, E. Toft, S. Kääb, and J. J. Struijk, “A history of drug-induced torsades de pointes is associated with t-wave morphological abnormalities,” Clinical Pharmacology & Therapeutics, vol. 103, no. 6, pp. 1100–1106, 2018.DOI
- [5]A. Sugrue, V. Kremen, B. Qiang, S. H. Sheldon, C. V. DeSimone, Y. Sapir, B. L. Striemer, P. Brady, S. J. Arisatham, M. J. Ackerman et al., “Electrocardiographic predictors of torsadogenic risk during dofetilide or sotalol initiation: utility of a novel t wave analysis program,” Cardiovascular drugs and therapy, vol. 29, no. 5, pp. 433–441, 2015.DOI
- [6]T. A. Manolis, A. A. Manolis, H. Melita, and A. S. Manolis, “Sudden unexpected death in epilepsy: The neuro-cardio-respiratory connection,” Seizure, vol. 64, pp. 65–73, 2019.DOI
- [7]E. Sharma, S. Gannon, B. McCauley, and A. F. Chu, “Sudden death in a patient with long qt syndrome presenting with an epileptic phenotype,” Annals of Noninvasive Electrocardiology, vol. 25, no. 6, p. e12753, 2020.DOI
- [8]J. Johnson, N. Hofman, C. Haglund, G. Cascino, A. Wilde, and M. Ackerman, “Identification of a possible pathogenic link between congenital long qt syndrome and epilepsy,” Neurology, vol. 72, no. 3, pp. 224–231, 2009.DOI
- [9]N. Strothoff, P. Wagner, T. Schaeffter, and W. Samek, “Deep learning for ecg analysis: Benchmarks and insights from ptb-xl,” IEEE journal of biomedical and health informatics, vol. 25, no. 5, pp. 1519–1528, 2020.
- [10]R. Jiang, C. C. Cheung, M. Garcia-Montero, B. Davies, J. Cao, D. Redfearn, Z. M. Laksman, S. Grondin, J. Atallah, C. A. Escudero et al., “Deep learning–augmented ecg analysis for screening and genotype prediction of congenital long qt syndrome,” JAMA cardiology, vol. 9, no. 4, pp. 377–384, 2024.DOI
- [11]G. Cinà, T. E. Röber, R. Goedhart, and Ş. İ. Birbil, “Why we do need explainable ai for healthcare,” Diagnostic and prognostic research, vol. 9, no. 1, p. 24, 2025.DOI
- [12]K. Palatzoglou, L. Pastika, J. Barker, E. Sielowonczyk, G. R. Khattak, B. Zeidabadi, A. H. Ribeiro, J. S. Ware, N. S. Peters, A. L. P. Ribeiro et al., “The cost of explainability in artificial intelligence-enhanced electrocardiogram models,” npj Digital Medicine, vol. 8, no. 1, p. 747, 2025.
- [13]Z. Wang and T. Oates, “Imaging time-series to improve classification and imputation,” arXiv preprint arXiv:1506.00327, 2015.arxiv.org/abs/1506.00327
- [14]N. Hatami, Y. Gavet, and J. Debayle, “Classification of time-series images using deep convolutional neural networks,” in Tenth international conference on machine vision (ICMV 2017), vol. 10696. SPIE, 2018, pp. 242–249.arxiv.org/abs/1710.00886
- [15]C. Kechris, J. Dan, and D. Atienza, “Time series saliency maps: Explaining models across multiple domains,” arXiv preprint arXiv:2505.13100, 2025.arxiv.org/abs/2505.13100
- [16]N. Kokhlykin, V. Miglani, B. Alsallakh, M. Martin, and O. Reblitz-Richardson, “Investigating sanity checks for saliency maps with image and text classification,” arXiv preprint arXiv:2106.07475, 2021.
- [17]A. Alahmadi, A. Davies, M. V. Chew, and C. Jay, “Pseudo-colouring an ecg enables lay people to detect qt-interval prolongation regardless of heart rate,” Plos one, vol. 15, no. 8, p. e0237854, 2020.
- [18]A. Alahmadi and M. Hasan, “Human-like visual computing advances explainability and few-shot learning in deep neural networks for complex physiological data,” arXiv preprint arXiv:2512.22349, 2025.
- [19]A. L. Goldberger, L. A. Amaral, L. Glass, J. M. Hausdorff, P. C. Ivanov, R. G. Mark, J. E. Mietus, G. B. Moody, C.-K. Peng, and H. E. Stanley, “Physiobank, physiotoolkit, and physionet: components of a new research resource for complex physiologic signals,” circulation, vol. 101, no. 23, pp. e215–e220, 2000.pubmed.ncbi.nlm.nih.gov/10851218
- [20]A. Chan, G. Isbister, C. Kirkpatrick, and S. Duffull, “Drug-induced qt prolongation and torsades de pointes: evaluation of a qt nomogram,” QJM: An International Journal of Medicine, vol. 100, no. 10, pp. 609–615, 2007.
- [21]UK Biobank, “Who we are,” https://www.ukbiobank.ac.uk/about-us/who-we-are/, 2026, accessed 27 July 2026.
- [22]PyTorch, “Models and pre-trained weights,” https://docs.pytorch.org/vision/main/models.html, 2026, accessed 28 July 2026.
- [23]C.-Y. Yang, P.-C. Chen, and W.-C. Huang, “Cross-domain transfer of eeg to eeg or ecg learning for cnn classification models,” Sensors, vol. 23, no. 5, p. 2458, 2023.
- [24]C. T. Yang, “Introduction,” https://captum.ai/docs/introduction.html, 2026, accessed 28 July 2026.
- [25]Z. Niu, G. Zhong, and H. Yu, “A review on the attention mechanism of deep learning,” Neurocomputing, vol. 452, pp. 48–62, 2021.
- [26]C.-K. Yeh, C.-Y. Hsieh, A. Suggala, D. I. Inouye, and P. K. Ravikumar, “On the (in) fidelity and sensitivity of explanations,” Advances in neural information processing systems, vol. 32, 2019.
- [27]G. Montavon, W. Samek, and K.-R. Müller, “Methods for interpreting and understanding deep neural networks,” Digital signal processing, vol. 73, pp. 1–15, 2018.
- [28]M. Hoang-Nguyen, T.-M. Hoang, and T. T. L. Le, “Comparing xai methods for identifying critical features and expert contributions in multi-expert edge computing attack detection,” in Proceedings of the 2025 10th International Conference on Cloud Computing and Internet of Things, 2025, pp. 15–22.