betaFeedback

WorksPhysics and Astronomy

Annihilation Vertex Reconstruction Algorithm with Single-Layer Timepix4 Detectors

Abstract

A study of antiproton-nucleus annihilations at rest on a variety of thin solid targets using slow extracted antiprotons is being prepared. To detect the charged annihilation products, the experiment will employ seven Timepix4 ASICs coupled to 500 um thick silicon sensors. These will be arranged in a cuboid geometry that covers the majority of the full solid angle around the target, enabling precise tracking of outgoing particles using only one layer of detectors. With these novel chips, the annihilation will be studied by measuring the total multiplicity, energy, and angular distribution of various prongs produced in a number of targets. A 3D reconstruction algorithm for determining the annihilation vertex from particle tracks in the single-plane detectors has been developed using Monte Carlo simulations. This allows for event-by-event reconstruction, making it possible to distinguish antiproton annihilations on the target from those occurring elsewhere. The measurements will also enable a study of possible final state interactions triggered by the primary annihilation mesons, their evolution with the nuclear mass and their branching ratios.

Introduction

Most antimatter experiments aim to precisely measure its properties in search for structural differences to the matter counterparts. Since the detection of antimatter is mainly done through its annihilation [1, 2, 3, 4, 5, 6], the understanding of the antiproton-nucleus (pˉ\bar{p}A) interaction at low energies is crucial. Previous measurements of pˉ\bar{p} annihilations showed that current Monte Carlo simulation models do not reproduce the measured data precisely [7, 8], as the annihilation mechanism, in terms of participating nucleons and their constituents, is not well established.

This project is a detailed study of the production of charged fragments (prongs) in antiproton-induced reactions across a range of nuclei at keV incident energy. The main goal is to conduct an in-depth investigation of the final state interactions (FSIs), triggered by primary annihilation mesons [9].

Annihilation Process. An antiproton at rest is captured by the atom and cascades down until it reaches an orbit close enough to the nuclear surface for it to annihilate on a nucleon [10]. The initial products of the annihilation are mesons. On average, for annihilation on a single proton, five pions are produced, of which three are charged [11, 12]. These pions, which have average kinetic energies of about 235 MeV, can penetrate the nucleus, excite it, and lead to the emission of protons, neutrons or heavier fragments [10]. This vast variety of possible FSIs has not yet been completely described by the existing models.

Branching ratios have only been reported for annihilations on He nuclei [13, 14] and the total prong multiplicities for a very limited number of nuclei [15].

Detector Requirements. A detection system designed for the study of pˉ\bar{p}A annihilations must be capable of measuring both the primarily produced mesons, which are minimum ionizing particles (MIPs), and heavier fragments, which are heavily ionising particles (HIPs). Given that the annihilation products are expected to be isotropically distributed, a detector with large solid-angle coverage is advantageous. To determine the MIP and HIP multiplicities for each annihilation, precise event tagging is required. Consequently, the detector must have sufficient time resolution to reliably distinguish individual annihilating antiprotons and correctly associate them with their respective prongs.

Antiproton Beam. This experiment requires a focused antiproton beam with energies that allow them to stop within the 1-3 μ\mum thick target foils. This is compatible with the trapping potentials used in experiments at CERN’s Antimatter Factory, typically of 10 keV. To resolve individual annihilation events, the rate must stay below the Timepix4 detector’s per-pixel dead time (∼500\sim500 ns), necessitating a slowly extracted beam.

Detection System and Target

The detector consists of seven Timepix4 hybrid pixel read-out chips [16] coupled to 500 μ\mum silicon sensors, arranged in a cuboid geometry. With this configuration the majority of the solid angle around a (1 ×\times 1) cm2^2 target foil is covered. The ASICs (application specific integrated circuits) have 448 × 512 pixels with a 55 µm pitch. The area of one sensor is (24.64×28.16) mm2(24.64 \times28.16)\,\mathrm{mm}^{2}. L-shaped chip carrier boards for the Timepix4 were specifically designed and provided by the NIKHEF institute, enabling the tight placement of the detectors, see Figure 1. The bin size for the time-of-arrival (ToA) of the signals is below 200 ps and the energy resolution of the time-over-threshold (ToT) is 1-2 keV.

Image not extracted

Figure 1. Three-quarter section of the seven Timepix4 chips on their L-shaped carrier boards. The target foil in the centre is shown in blue and the direction of the incoming antiproton beam is indicated by an arrow.

Monte Carlo Simulation

Simulations were carried out in both Geant4 [17, 18, 19] and FLUKA [20, 21]. The geometry of the setup includes the target foil, its mounting structure, the chip carrier boards and the vacuum chamber itself. In total 12 different foils were simulated, ranging from carbon to lead, as well as antiproton beams between 250 eV and 10 keV kinetic energy. Several physics models in Geant4 were explored, but ultimately the list FTFP INCLXX EMZ (v11.2.1) was used, which includes the Intranuclear Cascade de Liege (INCL) model [22] for antiproton annihilations at rest [23]. To obtain sufficient information about the process within the target and sensors, the step size of a particle propagation was chosen to be ≤5 μm\leq5\,\mu\mathrm{m}.

The simulations from both models were saved as ROOT [24] files, which were then digitised with the Allpix2 Semiconductor Detector Monte Carlo Simulation Framework [25], setting a bias voltage of 150 V and a depletion voltage of 100 V for the p-on-n sensor.

Vertex Reconstruction Algorithm

The data acquisition system of the Timepix4 provides a zero-suppressed, constant stream. To tag individual events in the data, the annihilation vertex is reconstructed for events with two or more tracks in the detectors. The algorithm has been developed using the simulations described in the previous section. In Figure 2 the whole process is shown as a flowchart and each step will be described here.

Image not extracted

Figure 2. Flowchart showing the vertex reconstruction process. The same process can be applied to both simulated data and raw data from real measurements.

Clustering I, Signals. Each detector produces its own data file, thus the Allpix2 output is also saved as seven individual files and the same code can be applied to both simulation and raw data. As a first step, the pixel signals are clustered such that all pixel hits belonging to a single particle are grouped. For the clustering, the DBSCAN [26] algorithm from python’s Scikit-learn libary [27] is applied to an array of pixel columns, rows and the ToA information. This algorithm was chosen as the number of clusters is not initially known and their shapes can vary from straight lines (MIPs), curls (electrons) or large blobs (HIPs). After this, each signal is assigned a cluster ID, the total number of cluster IDs corresponds to the total number of particles measured.

Signal Depth Reconstruction. The position of a signal is obtained from the pixel column and row, which can then easily be converted to xx and yy coordinates by knowing the geometry. In order to get the third coordinate zz within the 500 µm silicon sensor, the depth of the signal has to be reconstructed. This is possible with several methods [28]. One method relies on the lowest and highest ToA within a cluster, assigning them as entry and exit points of a particle track, given the particle is not stopped within the sensor. The method applied here makes use of the known drift time of the charge carries within the sensor. The local zz coordinate can be calculated using the ΔToA\Delta\mathrm{ToA} within a cluster, the bias voltage UBU_B applied to the sensor, the depletion voltage UDU_D, the mobility of the charge carriers (in this case holes) μh\mu_h and the thickness of the sensor dd [29]:

z(ΔToA)=d2UD(UD+UB)(1−exp⁡(2UDμhtd2))(1)z(\Delta\mathrm{ToA}) = \frac{d}{2U_D}(U_D + U_B)\left(1-\exp\left(\frac{2U_D\mu_h t}{d^2}\right)\right) \tag*{(1)}

This way, the local coordinates of pixel column, row and ToA are converted to global x,y,zx,y,z coordinates, where (0,0,0)(0,0,0) is the centre of the target foil.

Clustering II, Time. In this step the individual files for the seven detectors are merged to one, which then undergoes a second clustering process using the first time stamp of each cluster. This way all clusters (particles) belonging to one event (annihilation) are grouped together.

Is it a track? Each cluster can be assumed to have an elliptical shape for which the eccentricity can be calculated as focal distance over major axis length. As HIPs are mostly stopped within the sensor and deposit all their energy, they leave rounder clusters. Elongated straight clusters - tracks - are mostly produced by MIPs traversing the sensor. These tracks are crucial for the vertex reconstruction and therefore the whole data set is filtered for clusters with eccentricity >0.8> 0.8 and a cluster size >3> 3 pixels.

3D Parametrisation and Points of Closest Approach. Each track can be fitted by a 3D linear function using singular value decomposition, resulting in a parametrisation with one point on the line, its average, and a directional vector. Using these parameters the point of closest approach (PoCA) can be calculated. This is done for all possible pairs of nn tracks within each time bin, resulting in (n2)\binom{n}{2} points per event. Again DBSCAN is used on the PoCAs in each time bin, as this algorithm can also exclude outliers which could arise from cosmic rays or secondary particles decaying elsewhere. The parameter ε\varepsilon (maximum distance between two points for them to be considered as neighbours) was set to 5 mm, after exploring its effect on the number of reconstructed events. For ε>5\varepsilon> 5 mm, this number showed no significant change. The final value for the reconstructed vertex V⃗rec\vec{V}_{\mathrm{rec}} is taken as the average point of the largest cluster of PoCAs.

The simulated point of annihilation V⃗sim\vec{V}_{\mathrm{sim}} are compared to V⃗rec\vec{V}_{\mathrm{rec}} in each coordinate, see Figure 3. The histograms were fitted with Student-t distributions, as the tails are heavier than in normal distributions. This can be explained by the dependence of the resolution on the number of prongs measured. The means μ\mu of the distributions are very close to zero, showing there is no bias in the vertex fitting. The scale parameter σeff\sigma_{\mathrm{eff}} and the degrees of freedom ν\nu can be used to approximate the standard deviation of the distribution as σ=σeffν/(ν−2)\sigma= \sigma_{\mathrm{eff}}\sqrt{\nu/(\nu- 2)}:

Image not extracted

Figure 3. The differences between simulated and reconstructed vertex positions for xx, yy, zz, fitted with Student-t distributions.

σx=1.34 mmσy=1.36 mmσz=1.21 mm\sigma_x = 1.34\ \mathrm{mm}\qquad\sigma_y = 1.36\ \mathrm{mm}\qquad\sigma_z = 1.21\ \mathrm{mm}

Summary and Outlook

An algorithm has been developed through simulations, capable of reconstructing antiproton annihilation vertices using a single-layer silicon detector. It accurately identifies individual annihilation events on different nuclei, offering a spatial resolution below 1.5 mm, sufficient to distinguish between annihilations occurring on the target and those elsewhere. This work will be applied to a new pˉ\bar{\mathrm{p}} annihilation experiment at CERN’s Antimatter Factory, focusing on prong measurements for various target foils, and enabling further investigation of the possible final state interactions and their evolution with nuclear mass.

Acknowledgments

The authors express their gratitude to the Medipix4 Collaboration at CERN for providing the Timepix4 ASICs for the upcoming measurements, NIKHEF for providing the custom designed chip carrier boards, in particular to Martin van Beuzekom, and to the late Hannes Zmeskal for his substantial contribution in the design of the experiment. This research was funded in whole or in part by the Austrian Science Fund (FWF) P 34438. For open access purposes, the author has applied a CC BY public copyright license to any author accepted manuscript version arising from this submission.

References

  1. [1]Sauzerkopf C, Capon AA, Diermaier M, et al. Annihilation detector for an in-beam spectroscopy apparatus to measure the ground state hyperfine splitting of antihydrogen. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 2017;845:579–82. URL: https://linkinghub.elsevier.com/retrieve/pii/S0168900216305630. doi:10.1016/j.nima.2016.06.023; publisher: Elsevier BV.
  2. [2]Nagata Y, Kuroda N, Kolbinger B, et al. Monte-Carlo based performance assessment of ASACUSA’s antihydrogen detector. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 2018;910:90–5. doi:10.1016/J.NIMA.2018.09.013; publisher: Elsevier B.V.DOI
  3. [3]Storey J, Canali C, Aghion S, et al. Particle tracking at 4K: The Fast Annihilation Cryogenic Tracking (FACT) detector for the AEgIS antimatter gravity experiment. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 2013;732:437–41. URL: https://linkinghub.elsevier.com/retrieve/pii/S0168900213007419. doi:10.1016/j.nima.2013.05.130; publisher: Elsevier BV.DOI
  4. [4]Andresen G, Ashkezari M, Bertsche W, et al. Antihydrogen annihilation reconstruction with the ALPHA silicon detector. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 2012;684:73–81. URL: https://linkinghub.elsevier.com/retrieve/pii/S0168900212004615. doi:10.1016/j.nima.2012.04.082; publisher: Elsevier BV.DOI
  5. [5]Capra A, Amaudruz PA, Bishop D, et al. Design of a Radial TPC for Antihydrogen Gravity Measurement with ALPHA-g. In: Proceedings of the 12th International Conference on Low Energy Antiproton Physics (LEAP2016). Kanazawa, Japan: Journal of the Physical Society of Japan; 2017,URL: http://journals.jps.jp/doi/10.7566/JPSCP.18.011015. doi:10.7566/jpscp.18.011015.DOI
  6. [6]Aumann T, Bartmann W, Boine-Frankelheim O, et al. PUMA, antiProton unstable matter annihilation: PUMA collaboration. The European Physical Journal A 2022;58(5). URL: https://link.springer.com/10.1140/epja/s10050-022-00713-x. doi:10.1140/epja/s10050-022-00713-x; publisher: Springer Science and Business Media LLC.
  7. [7]Amsler C, Breuker H, Bumbar M, et al. Antiproton annihilation at rest in thin solid targets and comparison with Monte Carlo simulations. The European Physical Journal A 2014;50(11):225. URL: https://link.springer.com/10.1140/epja/s10050-024-01428-x. doi:10.1140/epja/s10050-024-01428-x.DOI
  8. [8]Aghion S, Amsler C, Ariga A, et al. Measurement of antiproton annihilation on Cu, Ag and Au with emulsion films. Journal of Instrumentation 2017;12(4). doi:10.1088/1748-0221/12/04/P04021; publisher: Institute of Physics Publishing.DOI
  9. [9]Kraxberger V, Bumbar M, Gligorova A, et al. Towards a Study of Low Energy Antiproton Annihilations on Nuclei. In: Proceedings of Science. EXA/LEAP 2024: Sissa Medialab; 2025, p. 104. URL: https://pos.sissa.it/480/104. doi:10.22323/1.480.0104.DOI
  10. [10]Plendl HS, Daniel H, Egidy Tv, et al. Antiproton-nucleus annihilation at rest. Physica Scripta 1993;48(2):160–3. URL: https://iopscience.iop.org/article/10.1088/0031-8949/48/2/006. doi:10.1088/0031-8949/48/2/006.DOI
  11. [11]Klemp E, Batty CJ, Richard JM. The antinucleon–nucleon interaction at low energy: Annihilation dynamics. Physics Reports 2005;413(4-5):197–317. URL: https://linkinghub.elsevier.com/retrieve/pii/S037015730501055. doi:10.1016/j.physrep.2005.03.002; arXiv: hep-ex/0501020.DOI
  12. [12]Amsler C. Proton-antiproton annihilation and meson spectroscopy with the Crystal Barrel. Reviews of Modern Physics 1998;70(4):1293–339. URL: https://link.aps.org/doi/10.1103/RevModPhys.70.1293. doi:10.1103/RevModPhys.70.1293.DOI
  13. [13]Montagna P, Bendiscioli G, Filippini V, et al. Single and multinucleon antiproton–4He annihilation at rest. Nuclear Physics A 2002;700(1-2):159–92. doi:10.1016/S0375-9474(01)01302–1; publisher: North-Holland.
  14. [14]Bendiscioli G, Filippini V, Rotondi A, et al. Pionic annihilation of antiprotons stopped on 3He. Nuclear Physics A 1990;518(4):683–708. URL: https://linkinghub.elsevier.com/retrieve/pii/0375947490901850. doi:10.1016/0375-9474(90)90185-0.DOI
  15. [15]Bendiscioli G, Khažev D. Antinucleon-nucleon and antinucleon-nucleus interaction. A review of experimental data. La Rivista Del Nuovo Cimento Series 3 1994;17(6):1–142. URL: http://link.springer.com/10.1007/BF02724447. doi:10.1007/BF02724447.DOI
  16. [16]Llopart X, Alozy J, Ballabriga R, et al. Timepix4, a large area pixel detector readout chip which can be tiled on 4 sides providing sub-200 ps timestamp binning. Journal of Instrumentation 2022;17(1):C01044. URL: https://iopscience.iop.org/article/10.1088/1748-0221/17/01/C01044. doi:10.1088/1748-0221/17/01/C01044.DOI
  17. [17]Allison J, Amako K, Apostolakis J, et al. Recent developments in Geant4. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 2016;835:186–225. doi:10.1016/J.NIMA.2016.06.125; publisher: Elsevier B.V.DOI
  18. [18]Allison J, Amako K, Apostolakis J, et al. Geant4 developments and applications. IEEE Transactions on Nuclear Science 2006;53(1):270–8. doi:10.1109/TNS.2006.869826.DOI
  19. [19]Agostinelli S, Allison J, Amako K, et al. Geant4—a simulation toolkit. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 2003;506(3):250–303. doi:10.1016/S0168-9002(03)01368-8; publisher: North-Holland.
  20. [20]Ahdida C, Bozzato D, Calzolari D, et al. New Capabilities of the FLUKA Multi-Purpose Code. Frontiers in Physics 2022;9:78253. URL: https://www.frontiersin.org/articles/10.3389/fphy.2021.788253/full. doi:10.3389/fphy.2021.788253.DOI
  21. [21]Battistoni G, Boehlen T, Cerutti F, et al. Overview of the FLUKA code. Annals of Nuclear Energy 2015;82:10–8. URL: https://linkinghub.elsevier.com/retrieve/pii/S0306454914005878. doi:10.1016/j.anucene.2014.11.007.DOI
  22. [22]Boudard A, Cugnon J, David JC, et al. New potentialities of the Liège intranuclear cascade (INCL) model for reactions induced by nucleons and light charged particles. Physical Review C - Nuclear Physics 2012;87(1):014606. URL: https://journals.aps.org/prc/abstract/10.1103/PhysRevC.87.014606. doi:10.1103/PhysRevC.87.014606; arXiv: 1210.3498 Publisher: American Physical Society.DOI
  23. [23]Zharenov D. Interaction of antiprotons with nuclear matter within the INCL model. Thesis; Université Paris-Saclay; 2023. URL: https://theses.hal.science/tel-04511526.DOI
  24. [24]Brun R, Rademakers F. ROOT - An Object Oriented Data Analysis Framework. Nuclear Instruments and Methods in Physics and Research Section A 1997;389(Proceedings AIHENP’96 Workshop, Lausanne, Sep. 1996):81–6. URL: https://root.cern.
  25. [25]Spannagel S, Wolters K, Hynds D, et al. Allpix2: A modular simulation framework for silicon detectors. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 2018;901:164–72. doi:10.1016/J.NIMA.2018.06.020; arXiv: 1806.05813 Publisher: North-Holland.DOI
  26. [26]Schubert E, Sander J, Ester M, et al. DBSCAN Revisited, Revisited: Why and How You Should (Still) Use DBSCAN. ACM Transactions on Database Systems 2017;42(3):1–21. URL: https://dl.acm.org/doi/10.1145/3068335. doi:10.1145/3068335.DOI
  27. [27]Pedregosa F, Varoquaux G, Gramfort A, et al. Scikit-learn: Machine learning in python. Journal of Machine Learning Research 2011;12(85):2825–30. URL: http://jmlr.org/papers/v12/pedregosa11a.html.arxiv.org/abs/1201.0490
  28. [28]Mánek P, Bergmann B, Burian P, et al. Improved algorithms for determination of particle directions with Timepix3. Journal of Instrumentation 2022;17(01):C01062. URL: https://iopscience.iop.org/article/10.1088/1748-0221/17/01/C01062. doi:10.1088/1748-0221/17/01/C01062.DOI
  29. [29]Bergmann B, Pichotka M, Pospisil S, et al. 3D track reconstruction capability of a silicon hybrid active pixel detector. The European Physical Journal C 2017;77(6):1–9. URL: https://link.springer.com/article/10.1140/epjc/s10052-017-4993-4. doi:10.1140/EPJC/S10052-017-4993-4; publisher: Springer.DOI

Paper details

vlnc:W_xcurajg8
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 6

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents