betaFeedback

WorksPhysics and Astronomy

The Electron-Gamma Coincidence Setup DAGOBERT

Abstract

The QCLAM electron spectrometer at the S-DALINAC electron accelerator at Technische Universität Darmstadt has been extended by the DAGOBERT γγ-detector array consisting of fast timing and high efficiency LaBr3_3:Ce detectors to perform electron-gamma coincidence measurements. The functionality of the setup and data acquisition system was demonstrated in a commissioning measurement on 12C^{12}\textrm{C} observing the 4.44 4.44\,MeV and 15.11 15.11\,MeV states. A medium-heavy nucleus, 96Ru^{96}\textrm{Ru}, has been studied for the first time up to excitation energies of 15 15\,MeV using the (e,e′γ)(e,e'γ) reaction. In particular, the angular distribution of the 21+2_1^+ state and the γγ-decay branching ratios of the mixed-symmetric 23+2_3^+ state were observed. DAGOBERT@QCLAM is a new and worldwide unique setup for nuclear structure studies of excitation and decay using purely electromagnetic probes, with a significantly improved sensitivity compared to previous experiments.

Highlights

  • DAGOBERT is worldwide unique for high-resolution (e,e′γe,e'\gamma) experiments.

  • First (e,e′γe,e'\gamma) experiment of an A≥90A \ge90 nucleus conducted.

  • Techniques for subtraction of indistinguishable coincident bremsstrahlung developed.

  • First (e,e′γe,e'\gamma) data on an off-yrast state analysed.

  • Investigated γ\gamma decays in (e,e′nγe,e'n\gamma) reaction.

Introduction

Electron scattering is an established tool for nuclear structure studies since 70 years [1]. Elastic electron scattering has been used to study the size and shape of the nuclear ground-state charge distribution by measuring electromagnetic form factors [1, 2, 3, 4]. It has also been used to explore the ground-state quadrupole moments of deformed nuclei [2, 5, 6], the nuclear magnetic dipole moments [7, 8], and the structure of individual nucleons [9]. Inelastic electron scattering allows for the measurement of nuclear resonance excitation energies, multipolarities of nuclear transitions, parity quantum numbers of nuclear excited states, and nuclear dynamics by measuring transition densities [10, 11, 12].

An interesting special case is an exclusive electron-gamma coincidence measurement, where the electromagnetic interaction is involved in both the excitation and the decay channel. A pioneering (e,e′γ)(e,e'\gamma) measurement was performed on the 21+2_1^+ state of 12^{12}C at the MUSL-2 accelerator at the University of Illinois [13, 14]. It was demonstrated that the reaction is capable of separating the longitudinal and transverse form factors including their relative sign in the measurement of the angular distribution of the emitted γ\gamma rays. Further measurements were conducted on light nuclei with low level densities such as 15^{15}N [15] and 16^{16}O [16]. Despite the success of these early (e,e′γ)(e,e'\gamma) experiments, the potential of the technique has not been fully exploited. The main experimental challenges were insufficient sensitivity due to low resolution for γ\gamma-energy measurements and low timing resolution for (e,e′γ)(e,e'\gamma) coincidences, needed for discriminating the signals of interest from the inevitable bremsstrahlung and beam-induced background. Advances in γ\gamma-ray detector technology, digital signal processing and the precise tuning of the electron beam promise a significant improvement of the experimental conditions, in particular the (e,e′γ)(e,e'\gamma) coincidence resolution, permitting to address nuclei with much higher level densities. This development paves the way for studying virtually all stable nuclei with the (e,e′γ)(e,e'\gamma) coincidence reaction.

This article reports on the design and commissioning of the new (e,e′γ)(e,e'\gamma) experimental setup at the Superconducting DArmstadt electron LINear ACcelerator (S-DALINAC) at the Institute for Nuclear Physics [17] at the Technische Universität Darmstadt. The accelerator delivers a 3-GHz continuous-wave electron beam to the experimental site of the large-acceptance Quadrupole CLAM shell magnetic spectrometer QCLAM [18]. The γ\gamma rays emitted in the (e,e′γ)(e,e'\gamma) reaction are detected with the recently established Darmstadt Array for coincident Gamma-ray OBservation in Electron scattering ReacTions (DAGOBERT) equipped with fast-timing and high-efficiency LaBr3_3:Ce scintillators [19].

The article is organized as follows. Chapter 2 describes the underlying formalism in more detail. Chapter 3 focuses on the S-DALINAC accelerator. The following Chapter 4 deals with the QCLAM electron spectrometer and the newly established electron-γ\gamma coincidence experimental facility, while Chapter 5 describes the electronics and data acquisition for (e,e′γ)(e,e'\gamma) experiments. The data analysis steps are discussed in Chapter 6. Chapter 7 points out the results and offers a discussion. Chapter 8 provides a summary and an outlook on future experiments.

Formalism

An advantage of using electrons for scattering experiments is their purely electromagnetic interaction through the exchange of virtual photons described with high accuracy within the framework of quantum electrodynamics (QED) [20]. Since the electromagnetic interaction is relatively weak, measurements on atomic nuclei are dominated by one-step processes, while multiple scattering processes can be neglected for momentum transfers relevant in nuclear structure studies [21]. This fact allows for a precise quantitative description of the reactions and a clean separation from the desired information on nuclear structure.

Inclusive Electron Scattering

In inclusive (e,e′)(e,e') electron scattering experiments, the incoming electron is scattered off a target and the scattered electron is detected. The measured inclusive cross sections contain information about the structure of the nucleus, which is accessible via a comparison of the experimentally determined differential cross sections dσexp⁡/dΩ\mathrm{d}\sigma_{\exp}/\mathrm{d}\Omega with the one of a theoretically calculated point-like, inert, and infinitely massive nucleus dσpoint/dΩ\mathrm{d}\sigma_{\mathrm{point}}/\mathrm{d}\Omega:

dσexp⁡dΩ=dσpointdΩ⋅R(Ex,q).(1)\frac{\mathrm{d}\sigma_{\exp}}{\mathrm{d}\Omega} = \frac{\mathrm{d}\sigma_{\mathrm{point}}}{\mathrm{d}\Omega} \cdot R(E_x,q). \tag*{(1)}

Here, Ω\Omega is the solid angle of the electron detection, RR denotes the nuclear response which depends on the excitation energy ExE_x and the momentum transfer qq of the electron to the nucleus.

The nuclear response function is a linear combination of the longitudinal and transverse form factors FLF_L and FTF_T [22, 23]:

R(Ex,q)=∣FL(q)∣2+12(1+2tan⁡2θ2)∣FT(q)∣2.(2)R(E_x,q) = \lvert F_L(q)\rvert^2 + \frac{1}{2}\left(1 + 2\tan^2\frac{\theta}{2}\right)\lvert F_T(q)\rvert^2. \tag*{(2)}

They contain information on the nuclear structure and describe the variation of the cross section as a function of the momentum transfer. The terms longitudinal and transverse refer to the polarization of the virtual photon. Elastic scattering processes (Ex=0E_x = 0) allow the investigation of ground-state properties such as charge radii. For a spinless nucleus R(Ex=0,q)=∣FL(q)∣2R(E_x = 0,q) = \lvert F_L(q)\rvert^2, where FLF_L represents the Fourier transformed charge distribution of the ground state. If the nucleus is excited (Ex>0E_x > 0) during the scattering process, the scattered electron loses energy and, hence, this process is called inelastic scattering. In this case both form factors must be considered. Inclusive electron scattering is an established method, in particular, to study isolated bound states of stable nuclei and their excitations from the ground state. Inclusive electron scattering does not provide information on all decay channels of excited states.

Exclusive Electron Scattering

Exclusive (e,e′γ)(e,e'\gamma) electron scattering experiments are a way to expand the potential of inclusive electron measurements. One or several particle(s) xx (e.g., neutrons, protons, α\alpha, γ\gamma) emitted during the deexcitation process of the nucleus are detected in coincidence to the scattered electron. This makes it possible to study the excitation and decay channels simultaneously.

The emitted particles are correlated with the range of excitation energies inferred from the energy loss of the coincidentally detected electrons. Moreover, decay multipole strengths can be determined by measuring the angular distribution of the emitted particle(s) xx [24, 25]. In the case of γ\gamma emission, it is sensitive to the interference term between the transverse and longitudinal form factors leading to a rotation of the angular distribution of the coincident particle emission, with the relative sign of the form factors indicating the direction of the rotation [13]. The measurement of the rotation angle of the angular distribution represents an alternative to the Rosenbluth separation method for the simultaneous extraction of FLF_L and FTF_T [14]. This was demonstrated, for example, in the study of the E0E0, E1E1 and E2E2 multipole strengths of 40Ca{}^{40}\mathrm{Ca} using the 40Ca(e,e′p)39K{}^{40}\mathrm{Ca}(e,e'p){}^{39}\mathrm{K} reaction [26]. Furthermore, in exclusive electron scattering, the coincidence condition along with energy conservation eliminates the radiative tail of the electron scattering signals [27], which is the main background source in the study of continuum excitations with electron scattering.

Electron-γ\gamma Coincidence Reaction

Possible processes contributing to the (e,e′γ)(e,e'\gamma) reaction are illustrated using Feynman diagrams in Figure 1.

Figure 1. Feynman diagrams of the (e,e′γ)(e,e'\gamma) reaction.

In inelastic electron scattering, a nucleus is excited from an initial state JiπJ_i^\pi to a state JmπJ_m^\pi (Figure 1a). By the emission of γ\gamma radiation, the nucleus decays into a state JfπJ_f^\pi with a lower excitation energy. In the case of a direct decay to the ground state, the energy of the emitted photon Eγ0=ExE_{\gamma0}=E_x corresponds to the energy loss of the electron during inelastic scattering. In competition to this quasi-prompt γ\gamma radiation, bremsstrahlung may be generated by the elastic scattering reaction of an electron with the target material leading to the same energy loss of the electron and, hence, the same photon energy, as the (e,e′γ0)(e,e'\gamma_0) reaction. Such a bremsstrahlung process can take place either before (Figure 1b) or after (Figure 1c) the elastic scattering of the electron off the target nucleus. The two processes, γ\gamma decay to the ground state and bremsstrahlung leading to the same energy loss of the scattered electron, can only be distinguished by the angular distribution of the emitted γ\gamma radiation. Due to the indistinguishability of the emitted photons, the two process are coherent [28]. Consequently, the total cross section of the (e,e′γ)(e,e'\gamma) reaction consists of three terms:

σ(e,e′γ)=σnucl+σbrems+σinter.(3)\sigma(e,e'\gamma)=\sigma_{\mathrm{nucl}}+\sigma_{\mathrm{brems}}+\sigma_{\mathrm{inter}}. \tag*{(3)}

Here, σnucl\sigma_{\mathrm{nucl}} describes the total cross section of the nuclear excitation with subsequent internal γ\gamma decay, σbrems\sigma_{\mathrm{brems}} the total cross section of the bremsstrahlung process, and σinter\sigma_{\mathrm{inter}} the interference term of the two previous processes.

The differential (e,e′γ)(e,e'\gamma) cross section for a nuclear excitation of a spin-zero ground state with subsequent γ\gamma decay is described in plane-wave Born approximation (PWBA) by [29] (see Appendix § 16 for details)

d3σnucldΩedΩγdω=2(Zαℏc4π)2(2J+1)⋅pfpiΓJradΓJΓJ(Ex−ω)2+ΓJ24⋅(VLWL+VTWT+VIWI+VSWS),(4)\frac{\mathrm{d}^{3}\sigma_{\mathrm{nucl}}}{\mathrm{d}\Omega_{e}\mathrm{d}\Omega_{\gamma}\mathrm{d}\omega} =2\left(\frac{Z\alpha\hbar c}{4\pi}\right)^{2}(2J+1)\cdot\frac{p_f}{p_i}\frac{\Gamma^{\mathrm{rad}}_{J}}{\Gamma_{J}}\frac{\Gamma_{J}}{(E_x-\omega)^{2}+\frac{\Gamma_{J}^{2}}{4}}\cdot(V_LW_L+V_TW_T+V_IW_I+V_SW_S), \tag*{(4)}

with the charge number of the excited nucleus ZZ, the spin of the excited state JJ, the initial electron momentum pip_i, the momentum of the scattered electron pfp_f, the partial width for the coincident photon decay of the excited state ΓJrad\Gamma^{\mathrm{rad}}_J, the total width of the excited state ΓJ\Gamma_J, the energy of the excited state ExE_x, the energy loss of the electron ω\omega and a sum of products of kinematic factors VV and generalized form factors WW [30]. The indices LL and TT stand for longitudinal and transverse, respectively, II for interference and SS for spin. The generalized form factors WW are proportional to the form factors FF of the nucleus

WL∝∣FL(q)∣2,(5)W_L \propto|F_L(q)|^2, \tag*{(5)}
WT∝∣FT(q)∣2,(6)W_T \propto|F_T(q)|^2, \tag*{(6)}
WI∝FL(q)⋅FT(q),(7)W_I \propto F_L(q) \cdot F_T(q), \tag*{(7)}
WS∝∣FT(q)∣2,(8)W_S \propto|F_T(q)|^2, \tag*{(8)}

where FL(q)F_L(q) and FT(q)F_T(q) are the longitudinal and transverse form factors for allowed values of transition angular momenta of the nuclear excitation under consideration [4]. Their relative sign is accessible through the interference term FL⋅FTF_L \cdot F_T. After integration over the photon angle, the well-known inclusive (e,e′)(e,e') cross section from Eqs. (1) and (2) is obtained. A full description of the formalism and explicit expressions for the kinematic factors VV and generalized form factors WW can be found in Appendix § 16.

The contribution of bremsstrahlung to the (e,e′γ)(e,e'\gamma) cross section can be calculated using PWBA with the Bethe-Heitler formula [31]:

d3σbremsdΩγdΩedω=(Zℏc2π)2α3pf/piω∣q⃗−k⃗∣c4(∣p⃗f×k⃗∣2(p~f⋅k~)2(4Ei2−∣q⃗−k⃗∣2c2)+∣p⃗i×k⃗∣2(p~i⋅k~)2(4Ef2−∣q⃗−k⃗∣2c2)−2(p⃗f×k⃗)(p⃗i×k⃗)(p~f⋅k~)(p~i⋅k~)(4EiEf−∣q⃗−k⃗∣2c2)+2ω2∣k⃗×q⃗∣2(p~f⋅k~)(p~i⋅k~)).(9)\frac{\mathrm{d}^3\sigma_{\mathrm{brems}}}{\mathrm{d}\Omega_\gamma\mathrm{d}\Omega_e \mathrm{d}\omega} = \left(\frac{Z\hbar c}{2\pi}\right)^2 \alpha^3 \frac{p_f/p_i}{\omega|\vec{q}-\vec{k}|c^4} \left( \frac{|\vec{p}_f \times\vec{k}|^2}{(\tilde{p}_f \cdot\tilde{k})^2}(4E_i^2-|\vec{q}-\vec{k}|^2c^2) + \frac{|\vec{p}_i \times\vec{k}|^2}{(\tilde{p}_i \cdot\tilde{k})^2}(4E_f^2-|\vec{q}-\vec{k}|^2c^2) - 2\frac{(\vec{p}_f \times\vec{k})(\vec{p}_i \times\vec{k})}{(\tilde{p}_f \cdot\tilde{k})(\tilde{p}_i \cdot\tilde{k})}(4E_iE_f-|\vec{q}-\vec{k}|^2c^2) + 2\omega^2\frac{|\vec{k}\times\vec{q}|^2}{(\tilde{p}_f \cdot\tilde{k})(\tilde{p}_i \cdot\tilde{k})} \right). \tag*{(9)}

Here, the energies EiE_i and EfE_f are the initial and final electron energy and kk represents the momentum of the photon. A tilde indicates a four-vector.

The corresponding coordinate system can be seen in Figure 2.

Figure 2. The relevant vectors and angles of the kinematics of an (e,e′γ)(e,e'\gamma) reaction are shown.

The scattering plane is defined by the vectors p⃗i\vec{p}_i and p⃗f\vec{p}_f. The coordinate system is chosen such that the scattering plane coincides with the xx-zz-plane and the zz-axis is defined by the momentum transfer q⃗=p⃗i−p⃗f\vec{q}=\vec{p}_i-\vec{p}_f. The vectors of momentum transfer q⃗\vec{q} and momentum of the emitted photon k⃗\vec{k} define the reaction plane. This coordinate system accounts for the symmetry of the PWBA with respect to the direction of q⃗\vec{q}.

An example of the double differential (e,e′γ)(e,e'\gamma) nuclear (blue line) and bremsstrahlung (orange line) cross sections is shown in Figure 3 for the population of the first 21+2^+_1 state of 96Ru{}^{96}\mathrm{Ru} as a function of the angle θ\theta, the angle of the emission direction of the photon k⃗\vec{k} relative to the momentum transfer vector q⃗\vec{q} for the nucleus (compare Figure 2). The cross sections from Eqs. (4) and (9) are averaged over the γ\gamma detector resolution Δω/ω=3%\Delta\omega/\omega=3\%. In addition, due to the small line width, the integration over ω\omega results in a contribution of the Breit-Wigner factor with the value 2π2\pi for Eq. (4). The green line shows the coherent sum of both contributions. Two conical maxima marked (a) and (b) are recognizable at angles of about 65.6∘65.6^\circ and 111.9∘111.9^\circ, respectively. They correspond to the maximum of the bremsstrahlung emission in direction of the incoming electrons (a) and electrons scattered towards the QCLAM spectrometer (b). The nuclear cross section shows a periodic behavior as a function of θ\theta, which is characteristic for electric quadrupole transitions (E2E2). The red rectangles represent the position of the six γ\gamma detectors in the performed experiment, see Table 3 and discussion below.

Figure 3. Double differential cross section of nuclear decay and bremsstrahlung contributions to the (e,e′γ)(e,e'\gamma) reaction in the xx-zz plane for the 21+2_1^+ state of 96Ru{}^{96}\mathrm{Ru} and Ei=85E_i=85 MeV. Positions of the γ\gamma detectors in the experiment are shown as red rectangles. The peak marked with (a) represents the maximum of the bremsstrahlung cone in direction of the incoming electron beam and the peak marked with (b) the corresponding maximum in direction of the scattered electrons towards the QCLAM spectrometer.

DetectorDistance (mm)θ\theta (°)Φ\Phi (°)
0263(2)310.6(2)67.7(1)
1172(2)336.2(0)0.0(0)
2280(2)311.2(2)−67.2(1)
3264(2)277.9(2)45.5(1)
4171(2)281.2(0)0.0(0)
5263(2)278.0(2)−44.6(1)

Table 3. Positioning of the six LaBr3_3:Ce detectors relative to the beam axis and target. The definition of θ\theta and Φ\Phi is explained in Figure 2.

S-DALINAC

The Superconducting DArmstadt electron LINear ACcelerator S-DALINAC at the Institute for Nuclear Physics [17] at Technische Universität Darmstadt is a recirculating electron accelerator for nuclear physics studies, which is capable of high resolution electron scattering experiments at low momentum transfer. The floor plan of the accelerator is shown in Figure 4.

Figure 4. The S-DALINAC [17] consisting of thermionic gun, injector and main accelerator (LINAC). The recirculations enable higher electron energies. Various experimental stations exist: DHIPS [32], COBRA [33], NEPTUN [34], QCLAM [35, 36] and LINTOTT [37, 38] spectrometer.

After emission from a thermionic electron source, the electrons are pre-accelerated by an electrostatic field and prepared for further acceleration in a chopper and pre-buncher section, imprinting a 2.997 GHz time structure on the continuous electron beam. The same frequency is applied to the superconducting cavities of the injector and the main linear accelerator (LINAC), which are operated at a temperature of 2 K. In the injector section, the electrons are accelerated to kinetic energies of up to 10 MeV. After exiting this section, they are guided into the main accelerator LINAC, where the electrons gain an additional up to 30 MeV in kinetic energy per passage. Depending on the energy required, the main accelerator can be operated in single-pass, single-recirculation or thrice-recirculation mode, resulting in a maximum design electron energy of 130 MeV. The electron beam can be transported to the Quadrupole CLAM shell magnetic spectrometer (QCLAM) [35, 36] with a large solid angle acceptance well suited for coincidence measurements.

For electron-γ\gamma coincidence reactions it is crucial to minimize any source of beam-induced background. To improve the beam quality at the spectrometer, the electron beam is guided through a high-energy scraper system [39]. The high-energy scraper acts as a filter for fluctuations in beam energy and helps to detect and control slow energy fluctuations leading to an enhanced beam energy resolution and stability. Additionally, it removes beam halo contributions. The high-energy scraper significantly improves beam quality albeit at the expense of beam intensity.

Electron-γ\gamma Coincidence Setup

Electron-γ\gamma coincidence measurements are made possible by the unique combination of the QCLAM electron spectrometer and the γ\gamma-ray detector system DAGOBERT using the high-quality electron beam provided by the S-DALINAC. A CAD model of the experimental setup is shown in Figure 5.

Overview of the new electron-gamma coincidence setup

Figure 5. Overview of the new (e,e′γ)(e,e^{\prime}\gamma) setup. ①: Beam focusing elements, ②: scattering chamber, ③: DAGOBERT, ④: QCLAM spectrometer, ⑤: magnetic field shielding.

The electron beam (green arrow) passes through a system of quadrupole magnets and steerer elements (1) that optimize the beam quality and the focusing on the target. A few meters downstream, the electron beam impinges the target located inside a vacuum scattering chamber [2]. The γ\gamma rays emitted in the (e,e′γ)(e,e'\gamma) reactions are detected with DAGOBERT [3], an array consisting of minimum six LaBr3_3:Ce scintillation detectors. The scattered electrons are observed with the QCLAM spectrometer [4]. In order to protect DAGOBERT from the magnetic fields of the QCLAM spectrometer, a dedicated shielding is mounted [5]. A detailed description of the individual components is provided in the following subsections.

QCLAM Electron Spectrometer

A cross section of the QCLAM spectrometer is shown in Figure 6. Electrons scattered into the QCLAM spectrometer

Figure 6. Cross-section through the QCLAM spectrometer. Electrons scattered off the target in the scattering chamber are focused horizontally in the quadrupole magnet and are bend by a dipole magnet towards the detector system.

first pass through a horizontally focusing quadrupole magnet. The horizontal focus maintains the large solid angle acceptance despite the geometric limitation of the following dipole magnet in the form of a narrow gap between the pole shoes. In the dipole magnet, electrons are deflected onto a circular path allowing for a momentum analysis and thus energy measurement. Imaging errors of the electron-optical system are reduced by a sextupole component which is created by a fifth, neutral pole of the quadrupole magnet and the dipole magnet’s concave (convex) shape of the entrance (exit). After passing through the magnet system, the electrons leave the vacuum through a mylar window and enter the detector system. Inside the detector system, shown in Figure 7, electrons first pass through three layers of multi wire drift chambers (MWDC), the X1/U double chamber and the X2 chamber, before entering a 2 cm thick plastic scintillation detector and a Cerenkov detector. Other arrangements of electron tracking and timing detectors could also fit the requirements of our measurements. This article addresses the functionality of the presently available setup. Position information from the MWDC is used to reconstruct the trajectory for each electron through the spectrometer.

QCLAM spectrometer detector system

Figure 7. (a) Cross section through the QCLAM spectrometer detector system consisting of three layers of multi wire drift chambers (MWDC), the X1/U double chamber ① and the X2 chamber ②, a plastic scintillation detector ③ and a Cerenkov detector ④. Photo-multiplier tubes ⑤ are attached to the scintillation and Cerenkov detectors. (b) Coordinate system of the QCLAM spectrometer detector system.

This is required to calculate the intersection with its curved focal plane. By measuring electron energy spectra of known nuclei, the intersection point can be associated with an energy value. The X1 and X2 chambers are used to calculate the dispersive coordinate and dispersive angle. The wires of the U chamber are rotated by 26.5∘26.5^\circ with respect to the wires of the other two chambers. The non-dispersive coordinate and angle are calculated from the measured U coordinate and the information of the other two chambers [40]. The scintillation detector is used to trigger the data acquisition and generate a position-independent timestamp. The time signal is generated from two photo-multiplier tubes at the opposite ends of the scintillator. The Cerenkov detector is used to suppress background by discriminating between electrons and γ\gamma radiation.

The spectrometer can be rotated about its pivot point allowing for the measurement of electrons scattered to angles between 25∘25^\circ and 155∘155^\circ relative to the incoming beam [35]. The key design parameters of the QCLAM spectrometer are summarized in Table 1 and further details can be found in Refs. [35, 41, 42, 43]. Of particular interest are the large solid angle acceptance of 35 msr and a momentum acceptance of ±10%\pm10\% essential for coincidence experiments over a broad excitation-energy range.

Design parameterValue
Maximum momentum220 MeV/c
Momentum acceptance (relative)±10\pm10 %
Energy resolution (relative)10−410^{-4}
Spectrometer angle range25∘25^\circ to 155∘155^\circ
Horizontal/Vertical angle acceptance±100\pm100 mrad
Solid-angle coverage35 msr
Dispersion (dipole magnet)2.21 cm/%
Maximum current (dipole magnet)320 A
Maximum current (quadrupole magnet)225 A

Table 1. Design parameters of the QCLAM spectrometer.

Beamline

A spatially well-tuned electron beam is crucial for (e,e′γ)(e,e'\gamma) measurements. The energy resolution of the scattered electrons measured in the QCLAM spectrometer depends strongly on the size and position of the beam spot on the target [35]. Therefore, an active beam-stabilization system using a feedback loop has been developed and implemented [44]. The purpose of this system is to stabilize the center beam position within a 200 μ\mum margin at the interaction point. The kick on the beam generated by the position control is mitigated with a secondary set of correction magnets to ensure an overall improvement of the transverse beam stability and, therefore, the spectrometer resolution. Furthermore, beam-induced background radiation from secondary reactions of electrons scattered off the beam pipe and other materials downstream the target is strongly reduced by a well-focused electron beam. Thus, two quadrupole magnets for improved focusing and two steerer elements for a better tuning of the electron beam are in operation a few meters upstream the scattering chamber, compare Figure 5.

Scattering Chamber

The scattering chamber for (e,e′γ)(e,e'\gamma) experiments is designed to minimize beam-induced background radiation and permit large solid angle coverage of the γ\gamma-ray detectors. The design of the scattering chamber is depicted in Figure 8.

Design of the scattering chamber

Figure 8. Design of the (e,e′γ)(e,e'\gamma) scattering chamber.

The electron beam enters the scattering chamber from the left through a 44.5 mm wide beam pipe. The primary electron beam passes the target and exits through a beam pipe with a diameter of 154 mm heading towards the beam dump accounting for the divergence of the beam after interaction with the target. The scattering chamber is made from aluminum with a wall thickness of 3 mm only to minimize beam-induced background. The flanges connecting the scattering chamber to the QCLAM spectrometer are attached to a box, which allows to select one of five QCLAM spectrometer positions in the interval from 47.5∘47.5^\circ to 132.5∘132.5^\circ in increments of 21.25∘21.25^\circ. The adapter required to connect scattering chamber and QCLAM spectrometer reduces the solid angle coverage to 25 msr.

Gamma Ray Detectors and Holding Structure

DAGOBERT is composed of cerium-doped lanthanum bromide crystals (LaBr3:Ce\mathrm{LaBr}_{3}\mathrm{:Ce}) of the type Saint-Gobain BrilLanCe®380 [45] with dimensions of 3′′×3′′3^{\prime\prime}\times3^{\prime\prime}. The crystals are characterized by excellent intrinsic time resolution of 0.7 ns important for random background suppression, good energy resolution (2.9 % at 662 keV) and high count rate capabilities due to the short decay time of the scintillation signals. Such detectors allow single count rates of several 100 kcps [43, 46]. The detectors are mounted inside tower-like mechanical holding structures as illustrated in Figure 5. Figure 9 provides a photo of the DAGOBERT array.

Photo of the DAGOBERT setup

Figure 9. Photo of the DAGOBERT setup. Detector towers are placed around the scattering chamber at the center of rotation of the QCLAM spectrometer. The picture was taken from the direction of the Faraday Cup beam pipe and points to the entrance beam pipe (compare Figure 8). The QCLAM spectrometer is positioned on the left side outside the image.

The angle in the scattering plane relative to the beam axis is adjusted by rotating the towers around the center of the scattering chamber. The tilt angle of the detector within the tower relative to the scattering plane and the distance between each LaBr3:Ce\mathrm{LaBr}_{3}\mathrm{:Ce} scintillator and the target can be set individually. Due to the increased intensity of bremsstrahlung background in forward direction of the electron beam (compare Figure 3), polar angles θ>180∘\theta>180^\circ are favored for reduced background. The current design of the setup consists of three detector towers, each accommodating at least three LaBr3:Ce\mathrm{LaBr}_{3}\mathrm{:Ce} at variable azimuthal angles.

For further passive shielding against beam-induced background, the crystals of the LaBr3:Ce\mathrm{LaBr}_{3}\mathrm{:Ce} detectors are mounted inside a housing consisting of a lead tube with 3 cm-thick walls, while the photo-multiplier tubes (PMT) in the rear area are shielded by 2 cm of lead. Additional lead shielding in front of the active detector surfaces reduces the low-energy background originating from the target. An additional copper shielding is used to attenuate X-rays emitted from the lead. The thickness of the lead and copper shielding can be varied by stacking the 5 mm thick lead filters and 2 mm thick copper filters, respectively.

Magnetic Field Shielding

The PMTs of the LaBr3:Ce\mathrm{LaBr}_{3}\mathrm{:Ce} detectors are sensitive to external magnetic fields which impact the amplification of the signals. Thus, they must be shielded against the far-reaching magnetic field of the QCLAM spectrometer quadrupole magnet. Simulations with the software CST Studio Suite 2020 [47] were performed to estimate the magnetic field strength at the position of the scintillation detectors. Figure 10 shows simulated field maps for the most forward (47.5∘47.5^\circ) and backward (132.5∘132.5^\circ) electron-scattering angles without shielding and with one- or two-stage shielding.

Figure 10. CST simulation of magnetic field maps for different spectrometer angles (top row: θSpec=47.5∘\theta_{\mathrm{Spec}} = 47.5^\circ and bottom row: θSpec=132.5∘\theta_{\mathrm{Spec}} = 132.5^\circ) with and without magnetic field shielding. The first column represents no shielding. The second column has a magnetic field shielding in front of the QCLAM spectrometer quadrupole magnet. The third column has a shielding in front of the QCLAM spectrometer quadrupole magnet and on the side of the second γ\gamma-ray detector tower. The direction of the electron beam is indicated by the vertical arrows.

The first stage of magnetic field shielding consists of a 5 mm thick iron plate in front of the quadrupole magnet, leaving the aperture of the spectrometer free, which reduces the magnetic field strength towards the scattering chamber. The second stage consists of an additional 5 mm thick iron plate at the side of a detector tower. All simulations were performed with the maximum current of the QCLAM spectrometer quadrupole magnet of 225 A. The two-stage shielding leads to a reduction of the magnetic field strength on the detector surface by one order of magnitude from 2.4 mT to 0.3 mT for the 132.5∘132.5^\circ setup.

Performance of DAGOBERT@QCLAM

The performance of the (e,e′γ)(e,e'\gamma) setup can be quantified by the electro-photo production coincidence resolution

R=EiΔEx⋅EγΔEγ⋅1Γ(Tcoin),(10)\mathcal{R} = \frac{E_i}{\Delta E_x} \cdot\frac{E_\gamma}{\Delta E_\gamma} \cdot\frac{1}{\Gamma(T_{\mathrm{coin}})}, \tag*{(10)}

defined as the product of the energy resolutions E/ΔEE/\Delta E for the detection of the scattered electrons and the produced photons per coincidence time resolution denoted by Γ(Tcoin)\Gamma(T_{\mathrm{coin}}). All resolutions are given as full width at half maximum (FWHM).

In Table 2, a comparison between the performance of the first (e,e′γ)(e,e'\gamma) experiment conducted at the University of Illinois [13, 14] on the target nucleus 12C{}^{12}\mathrm{C}, a 12C(e,e′γ){}^{12}\mathrm{C}(e,e'\gamma) experiment with a preliminary version of DAGOBERT@QCLAM and a 96Ru(e,e′γ){}^{96}\mathrm{Ru}(e,e'\gamma) measurement with the full DAGOBERT setup is given. In the preliminary experimental setup only three LaBr3_3:Ce detectors, a scattering chamber not optimized for (e,e′γ)(e,e'\gamma) experiments and a standard beamline without the improvements described in § 5.2 were used.

Comparison between the performance of the first (e,e′γe,e'\gamma) experiment at the University of Illinois [13, 14] with a 12C{}^{12}\mathrm{C} target and the 12C(e,e′γ){}^{12}\mathrm{C}(e,e'\gamma) experimental campaign using a preliminary setup of DAGOBERT@QCLAM in 2019 [43]. Additionally, the performance parameters of the full DAGOBERT@QCLAM setup from the 96Ru(e,e′γ){}^{96}\mathrm{Ru}(e,e'\gamma) experiment (see § 7) are shown.

Parameters12C{}^{12}\mathrm{C} Illinois [13, 14]12C{}^{12}\mathrm{C} pre setup [43]96Ru{}^{96}\mathrm{Ru} this work
Electron beam energy EiE_i66.9 MeV30 MeV85 MeV
ΔEx\Delta E_x for 2+2^+ state of 12C{}^{12}\mathrm{C} / of 96Ru{}^{96}\mathrm{Ru}100 keV41 keV86.4(1.0) keV
ΔEx/Ei\Delta E_x/E_i for 2+2^+ state of 12C{}^{12}\mathrm{C} / of 96Ru{}^{96}\mathrm{Ru}0.15 %0.14 %0.102(2) %
Electron solid angle acceptance/4π4\pi0.04 %0.28 %0.20 %
ΔEγ\Delta E_\gamma for 2+2^+ state of 12C{}^{12}\mathrm{C} / at 4.44 MeV287 keV53.3 keV71.1(2) keV{sup}1`
ΔEγ/Eγ\Delta E_\gamma/E_\gamma for 2+2^+ state of 12C{}^{12}\mathrm{C} / at 4.44 MeV6.46 %1.20 %1.60(1) %{sup}2`
Total photopeak efficiency at 1.33 MeV—0.21 %0.61(2) %
Coincidence time resolution Γ(Tcoin)\Gamma(T_{\mathrm{coin}})20 ns3.1 ns1.9 ns
Width of coincidence time gate43.5 ns5 ns4 ns
R\mathcal{R}0.52 ps−1^{-1}19.7 ps−1^{-1}32.3 ps−1^{-1}

Table 2.

Comparing the two 12C(e,e′γ){}^{12}\mathrm{C}(e,e'\gamma) experiments the total and relative electron and γ\gamma-ray energy resolution, the coincidence time resolution and the width of the coincidence time gate are all superior for the DAGOBERT@QCLAM setup. This leads to an improvement of R\mathcal{R} by a factor of 38 compared to the first (e,e′γ)(e,e'\gamma) experiment at the University of Illinois [13, 14] from 0.520.52 ps−1^{-1} to 19.719.7 ps−1^{-1}.

For the 96Ru(e,e′γ){}^{96}\mathrm{Ru}(e,e'\gamma) measurement, the QCLAM spectrometer energy resolution was obtained from the excitation energy spectrum in Figure 21. The value of ΔEx\Delta E_x is larger compared to the 12C{}^{12}\mathrm{C} measurement due to energy loss straggling in the target [48]. The 96Ru{}^{96}\mathrm{Ru} target had a larger areal density and charge number compared to 12C{}^{12}\mathrm{C} and is backed with 197Au{}^{197}\mathrm{Au} from both sides. The γ\gamma-ray energy resolution and the total photopeak efficiency of the DAGOBERT setup was obtained from calibration measurements (compare § 9.1.1). The determination of the coincident time resolution is described in § 9.2 and was further improved by a factor of 1.6 compared to the 12C{}^{12}\mathrm{C} measurement. In total, the electro-photo production coincidence resolution R\mathcal{R} exhibits a value of R=32.3\mathcal{R} = 32.3 ps−1^{-1}. Along with a five times larger acceptance for scattered electrons, this results in a two-to-three orders of magnitude higher sensitivity to electro-photo production reactions as compared to the pioneering set-up at Illinois.

Figure 21. Projection of the ExE_{x}-EγE_{\gamma} matrix on the ExE_{x} axis. Fits of asymmetric Gaussian functions with radiative tail and linear background to the recognizable peaks are shown in orange.

Electronics and Data Acquisition

The coincidence data acquisition system (DAQ) is composed of a newly developed DAQ for DAGOBERT combined with the existing DAQ for the QCLAM spectrometer [42]. Both DAQs are based on the multi-branch system (MBS) [49] developed by GSI. The modules of the QCLAM spectrometer and DAGOBERT DAQs are based on the VME and NIM standards. Signals from the LaBr3_3:Ce detectors are processed by 14-bit SIS3316 FADCs from Struck Innovative Systems GmbH [50]. A key parameter of these modules are a 14 bit accuracy for the 2 V / 5 V range of signals and a time resolution up to 50 ps.

For electron-γ\gamma coincidence measurements, both DAQs are combined following the scheme given in Figure 11. Scattered electrons e′e' entering the QCLAM spectrometer detector system produce signals in the MWDC and PMTs of the scintillation and Cerenkov detectors. These signals are processed in the QCLAM spectrometer DAQ. The QCLAM trigger logic enables the combination of signals from the PMTs and the Cerenkov detector for the QCLAM trigger to suppress contributions from γ\gamma-ray background, e.g. cosmic rays. Photons detected with one of the LaBr3_3:Ce scintillation detectors produce a γ\gamma signal in the DAGOBERT DAQ. The DAGOBERT trigger is built and in addition signals of the PMTs of the QCLAM spectrometer scintillation detectors are stored for a reference time stamp. When the LaBr and QCLAM trigger are generated within a preset time window, a coincidence trigger is built and sent back to the two data acquisition systems for activation of the writing of the corresponding two data types.

Figure 11. Concept of the electron-γ\gamma coincidence data acquisition system.

For the further analysis of the electron-γ\gamma coincidence data, QCLAM and DAGOBERT events are combined to form coincidence events. This is achieved by a trigger pattern matching due to the information from the PMT signals of the QCLAM spectrometer scintillator stored in both data sets. QCLAM spectrometer events are unpacked [42] and then evaluated using a custom-made software tool performing standard corrections such as energy calibrations and corrections of imaging errors of the electron-optical system. These corrections are described in more detail in the following Chapter § 7. Raw data recorded by the DAGOBERT DAQ is unpacked with an adapted UCESB [51] unpacker and evaluated by a custom-made software tool. Specific corrections such as a rate-dependent energy shift are performed.

Commissioning of the DAGOBERT setup

The first (e,e′γe,e'\gamma) experiments with the full established DAGOBERT setup were performed on 12^{12}C for calibration purposes and 96^{96}Ru to study the γ\gamma-decay branching ratio of its mixed-symmetry 23+2^+_3 state [52]. The electron beam energy was 85 MeV with beam currents of about 100 nA. The QCLAM spectrometer was placed at a scattering angle of 46.3°. Its dipole and quadrupole magnetic fields were set to IDipole=112I_{\mathrm{Dipole}} = 112 A and IQuadrupole=140I_{\mathrm{Quadrupole}} = 140 A, respectively, to detect and momentum analyze electrons with energy losses in the range of 0 − 15 MeV. The beam time lasted for approximately 250 h. The emitted γ\gamma rays were detected with DAGOBERT consisting of six LaBr3_3:Ce detectors positioned in two towers with three detectors each. Their position in terms of distances from the target and angles θ\theta and Φ\Phi defined by Figure 2 are summarized in Table 3.

For the measurements three targets were mounted on a remote controlled target ladder: 12^{12}C, BeO, and 96^{96}Ru. The 12^{12}C foil with an areal density of 10 mg/cm2^2 was used to calibrate the energy and efficiency of the QCLAM spectrometer. The second position was kept empty for electron beam and background optimization purposes. The BeO target was also used for electron beam optimization. The 96^{96}Ru target with an areal density of 28 mg/cm2^2 was sandwiched between two foils of 197Au^{197}\mathrm{Au} with a total areal density of 13.6 mg/cm2^2. In the following sections the necessary steps are presented to obtain an electron-γ\gamma coincidence ExE_x-EγE_\gamma matrix that can be further analyzed.

Calibration: Electron Data

Before the data of the QCLAM spectrometer can be used for analysis, corrections and calibrations on the measured raw signal need to be performed. These corrections and calibrations are discussed in detail in the following subsections.

Correction of Aberration

The focal plane of the QCLAM spectrometer is curved due to the electron-optical imaging properties of the magnet system. This is illustrated in Figure 12.

Figure 12. Deflection of the scattered electrons in the magnetic field of the QCLAM spectrometer. The magnetic system deflects electrons with the same momentum but different vertical entry angles to the same point on the curved focal plane. In the straight detector plane, the scattered electrons no longer hit the same point.

The detector plane in which the drift chambers are located, on the other hand, is designed to be straight due to mechanical conditions. This results in a spatial mismatch between the spectrometer’s focal plane and its MWDCs, which must be corrected for in the data analysis. If scattered electrons with a different angle but the same momentum enter the QCLAM spectrometer, they hit the curved focal plane at the same point. This is not the case in the detector plane. For a fixed momentum, the dispersive position xx and the dispersive angle ϕ\phi in the detector system are coupled. Thus, aberration errors occur which have to be corrected prior to the energy calibration.

The aim of the correction is a mapping of the measured data to a corrected coordinate xcorrx_{\mathrm{corr}} using an empirical polynomial approach

xcorr(x,ϕ)=∑i,jaijxiϕcorrj,(11)x_{\mathrm{corr}}(x,\phi)=\sum_{i,j}a_{ij}x^i\phi_{\mathrm{corr}}^j, \tag*{(11)}

where the parameters aija_{ij} are determined by a fit to calibration data. In a first step, the dependence of the dispersive angle on the dispersive coordinate is extracted using

ϕcorr(x)=ϕ−ϕ(x)=ϕ−(a+b⋅x),(12)\phi_{\mathrm{corr}}(x) = \phi- \phi(x) = \phi- (a + b \cdot x), \tag*{(12)}

with free parameters aa and bb. For their calibration, x−ϕx-\phi tuples distributed over the full acceptance of the spectrometer are required to which an xcorrx_{\mathrm{corr}} value is assigned. For this purpose, a series of measurements of elastically scattered electrons at different magnetic field settings are performed covering the range from minimum to maximum dispersive positions in multiple steps. A summed matrix of all measurements is shown in Figure 13a. Here, elastic lines of 96Ru{}^{96}\mathrm{Ru} are visible for 11 different magnetic field settings. These lines are curved due to the aberration of the electron spectrometer. After the correction of the aberration shown in Figure 13b, straight vertical lines are obtained. This significantly improves the energy resolution of the QCLAM spectrometer, e.g for the magnetic field setting where the elastic line is positioned in the center of the focal plane from a FWHM of 1186 keV to 186 keV.

Energy Calibration

An energy calibration of the QCLAM spectrometer is performed using the xcorrx_{\mathrm{corr}} coordinates in a 12C(e,e′){}^{12}\mathrm{C}(e,e') measurement. The spectrum depicted in Figure 14 exhibits three clearly visible peaks. They originate from elastic scattering, i.e. Ex=0.0E_x = 0.0 MeV, the excitation of the 21+2_1^+ state at Ex=4.44E_x = 4.44 MeV and the 02+0_2^+ Hoyle state [53] at Ex=7.65E_x = 7.65 MeV, respectively [54].

Figure 14. 12C{}^{12}\mathrm{C} spectrum measured in inclusive electron scattering. The elastic line 01+0^{+}_{1}, the 21+2^{+}_{1} and the 02+0^{+}_{2} Hoyle state [53] are used for an energy calibration.

The peak shape in the measured spectrum is parameterized by an asymmetric Gaussian function with an exponential tail [55]. A second order polynomial is used to determine the energy calibration to account for the non-linearity of the focal plane of the spectrometer:

Ex(xcorr)=a+b⋅xcorr+c⋅xcorr2.(13)E_x(x_{\mathrm{corr}}) = a + b \cdot x_{\mathrm{corr}} + c \cdot x_{\mathrm{corr}}^2. \tag*{(13)}

To apply the energy calibration using the 12C{}^{12}\mathrm{C} target to the 96Ru(e,e′γ){}^{96}\mathrm{Ru}(e,e'\gamma) experiment, a shift in the peak positions must be taken into account. The reason for this shift is, on the one hand, the different mass of the targets, which leads to a constant shift of the energy due to different recoil factors. On the other hand, there are drifts in the peak position between the different measurement runs. These drifts are caused by different environmental conditions, such as fluctuations in the electron beam energy or the magnetic field of the QCLAM spectrometer. The shifts are determined by fitting the electron peak formula to the runs of the 96Ru(e,e′γ){}^{96}\mathrm{Ru}(e,e'\gamma) measurement and then shifting the determined peak position of the elastic line to the position for the 12C(e,e′){}^{12}\mathrm{C}(e,e') measurement.

Relative Efficiency Correction

In a next step the relative efficiency of the QCLAM spectrometer is investigated using the 12C{}^{12}\mathrm{C} target. A white spectrum was recorded, where the energies and angles of the detected electrons are homogeneously distributed over the focal plane of the detector system. These requirements are fulfilled at high excitation energies due to the exponentially increasing density of excited states resulting in smooth and structureless excitation-energy spectra. The resulting x−ϕx-\phi data are normalized to the total number of events providing the relative efficiency for these coordinates.

Calibration: Gamma Data

The required corrections and calibrations of the raw LaBr3_3:Ce data are discussed in detail in the following.

Count-Rate Correction

Count-rate dependent gain shifts of the LaBr3_3:Ce detectors are corrected for by measurements with a 60Co{}^{60}\mathrm{Co} source with an activity of 20 MBq using the two known lines at 1.17 MeV and 1.33 MeV [56]. LaBr3_3:Ce spectra are recorded for different count rates achieved by varying the distance between the 60Co{}^{60}\mathrm{Co} source and the detectors. The rate-corrected integrated detector signals are parameterized by

xcorr,1(r,x)=(1+a⋅r)⋅b⋅x,(14)x_{\mathrm{corr},1}(r,x) = (1 + a \cdot r) \cdot b \cdot x, \tag*{(14)}

which scales linearly with the rate rr in units of cps and is proportional to the integrated detector signal xx. The integrated detector signal is the area of the trace of the signal, which is associated to an energy value. Detector 2 showed strong deviations from the equation above, thus an empirical formula

xcorr,2(r,x)=c⋅xrd+e⋅rf,(15)x_{\mathrm{corr},2}(r,x) = \frac{c \cdot x}{r^d + e \cdot r^f}, \tag*{(15)}
Uncorrected $x-\phi$ plot

(a) Uncorrected x−ϕx-\phi plot.

Corrected $x_{\mathrm{corr}}-\phi_{\mathrm{corr}}$ plot

(b) Corrected xcorr−ϕcorrx_{\mathrm{corr}}-\phi_{\mathrm{corr}} plot.

Figure 13. Correction of the electron-optical aberration. The elastic line of 96Ru{}^{96}\mathrm{Ru} was shifted over the focal plane by using 11 different magnetic field settings.

was used instead. The parameters aa, bb, cc, dd and ff are obtained by fitting the equations above to the measured rate dependence when changing the distance for the source to the detectors. The resulting parameters are summarized in Table 4.

Detectoraabbccddeeff
0−3.91(13)⋅10−8-3.91(13)\cdot10^{-8}0.28981(8)0.28981(8)————
12.64(8)⋅10−92.64(8)\cdot10^{-9}0.20319(5)0.20319(5)————
2——0.3585(3)0.3585(3)0.1623(16)0.1623(16)0.0190(10)0.0190(10)0.5919(53)0.5919(53)
31.1(19)⋅10−91.1(19)\cdot10^{-9}0.13537(2)0.13537(2)————
41.901(96)⋅10−81.901(96)\cdot10^{-8}0.04087(1)0.04087(1)————
5−1.161(19)⋅10−7-1.161(19)\cdot10^{-7}0.14489(5)0.14489(5)————

Table 4. Fit parameters of rate dependence correction given by Eqs. (14) and (15). The parameters are determined from the rates rr (measured in units cps) for the 1.17 MeV and 1.33 MeV peaks of a 60Co{}^{60}\mathrm{Co} source.

By correcting for the rate dependence, the energy resolution of the LaBr3\mathrm{LaBr}_3:Ce detectors is improved by up to 17%.

Energy Calibration

For the energy calibration of the γ\gamma spectra a 226Ra{}^{226}\mathrm{Ra} source for γ\gamma-ray energies <3<3 MeV and the 35Cl(n,γ)36Cl{}^{35}\mathrm{Cl}(n,\gamma){}^{36}\mathrm{Cl} reaction for energies >3>3 MeV was used. The latter spectrum can be seen in Figure 15.

Figure 15. LaBr3_3:Ce spectrum of the 35^{35}Cl(n,γ)36(n,\gamma)^{36}Cl reaction using an Am − Be source for energy calibration up to 9 MeV. The spectrum is divided into three parts: intrinsic radioactivity of the detector, Be + α→12\alpha\rightarrow{}^{12}C reaction and subsequent γ\gamma decay and 35^{35}Cl(n,γ)36(n,\gamma)^{36}Cl reaction. DE: Double Escape Peak, SE: Single Escape Peak.

The energy calibration was then performed using a second order polynomial. An overall mean energy resolution of 43.7(1) keV at Eγ=1.33E_{\gamma}=1.33 MeV resulting in a relative energy resolution of 3.28(1) % was obtained for the six LaBr3_3:Ce detectors of the DAGOBERT setup. At the same γ\gamma-ray energy DAGOBERT with six LaBr3_3:Ce detectors in the configuration of Figure 5 features a total photopeak efficiency of 0.61(2) %. For the comparison of the performance in § 5.6 the relative energy resolution is taken at Eγ=4.44E_{\gamma}=4.44 MeV and amounts to 1.60(1) %.

Calibration: Coincidence Data

For an enhanced signal-to-background ratio an optimized time resolution between the electron and γ\gamma-ray data is of particular importance. The uncorrected time difference between QCLAM (tet_e) and DAGOBERT (tγt_{\gamma}) events

Δt=tγ−te(16)\Delta t=t_{\gamma}-t_e \tag*{(16)}

is displayed in orange in Figure 16.

Figure 16. Time difference spectrum of QCLAM and DAGOBERT trigger timestamps. Blue: time-of-flight corrected spectrum, orange: uncorrected measured spectrum. In addition, time gates for background subtraction (compare § 9.3) are shown. Green: true events including random coincidences, red: random coincidences only.

In blue the corrected time difference is shown. The correction is presented in the following.

The present prompt time-difference peak has a full width at half maximum (FWHM) of 5.6 ns. As depicted in Figure 12, depending on their energy and scattering angle, the highly relativistic electrons (v≈cv\approx c) travel different path

lengths from the scattering target to the detection system of the spectrometer resulting in a variation of the time-of-flight (tof) values broadening the prompt peak in the time-difference spectrum. A correction is performed to restore the time resolution using the parameterization

ttof(x,ϕ)=∑i,jai,jxiϕj,(17)t_{\mathrm{tof}}(x,\phi)=\sum_{i,j}a_{i,j}x^i\phi^j, \tag*{(17)}

with the dispersive coordinate xx and the dispersive angle ϕ\phi. The parameters ai,ja_{i,j} with i,j=0,1i,j = 0, 1 are determined iteratively. For each subsequent correction, the previous corrections are applied to the time difference. Starting from the correction of the xx-dependence, the ϕ\phi-dependence and the x⋅ϕx \cdot\phi-dependence.

Furthermore, the trigger time of the emitted γ\gamma rays detected by DAGOBERT must be corrected because the trigger pulse depends on the waveform, which in turn depends on the amplitude and thus on the γ\gamma-ray energy. The correction for the γ\gamma-ray energy dependence on the time difference is accomplished by the fit of a quadratic function to the prompt peak in the time difference spectrum. An example is shown in Figure 17 for detector 5.

Time difference dependence of photon energy for detector number 5

Figure 17. Time difference dependence of EγE_\gamma for detector number 5. In the upper panel the photon energy EγE_\gamma versus time difference Δt\Delta t is shown. An energy dependence of the time difference peak is visible. For the correction of the effect, a quadratic function is fitted to the peak position of the time difference for EγE_\gamma gates of ±0.5\pm0.5 MeV in the lower panel.

In the upper panel the photon energy EγE_\gamma is plotted against the time difference. A dependence of Δt\Delta t on EγE_\gamma is clearly visible. It can be corrected by fitting a quadratic function to the centroid of the peak in the time difference spectrum.

Finally, the corrected time difference is given by:

Δtcorr=Δt−ttof−ΔtEγ.(18)\Delta t_{\mathrm{corr}} = \Delta t - t_{\mathrm{tof}} - \Delta t_{E_{\gamma}}. \tag*{(18)}

Applying both corrections, the time resolution of the coincidence peak was improved from 5.6 ns to 1.9 ns (FWHM). The corrected time-difference spectrum is shown in blue in Figure 16.

Correction for Random Coincidences

Random coincidence events are a major source of background and therefore need to be accounted for in the analysis. A narrow time gate of ±2\pm2 ns is set on the events in the prompt peak of the time difference spectrum, Figure 16. Furthermore, random coincidences are selected by gating on the left and right from the prompt peak with the same width and subtracted from the events of the prompt peak gate.

ExE_x-EγE_{\gamma} Matrix

Figure 18 and Figure 19 display ExE_x-EγE_{\gamma} matrices corrected for the background from random coincidences and the relative efficiencies. In such a matrix, the energy loss of the electrons ExE_x is displayed on the xx-axis, the γ\gamma-ray energy EγE_{\gamma} on the yy-axis and the number of events per channel on the zz-axis. The full measured matrix up to excitation energies of 15 MeV and a zoom on low excitation energies can be seen in Figure 18a and Figure 18b, respectively.

Background- and efficiency-corrected $E_x$–$E_\gamma$ matrix for $^{96}\mathrm{Ru}$

Figure 18. (a) Full ExE_x–EγE_\gamma matrix up to excitation energies of 15 MeV. (b) Zoom at low excitation energies. Background- and efficiency-corrected ExE_x–EγE_\gamma matrix for 96Ru^{96}\mathrm{Ru} at an electron beam energy Ei=85E_i = 85 MeV and a scattering angle θSpec=46.3∘\theta_{\mathrm{Spec}} = 46.3^\circ.

Full $E_x$-$E_\gamma$ matrix up to excitation energies of 15 MeV and zoom at low excitation energies

Figure 19. (a) Full ExE_x-EγE_\gamma matrix up to excitation energies of 15 MeV. (b) Zoom at low excitation energies. Same as Figure 18, but with additional subtraction of the bremsstrahlung background.

Parts of the events along the Ex=EγE_x = E_{\gamma} diagonal must be attributed to bremsstrahlung due to its indistinguishability from ground-state γ\gamma decay. The bremsstrahlung contribution decreases with increasing energy loss of the electrons, i.e., with increasing excitation energy. At low excitation energies discrete states can be seen. One of these states is the 21+2^{+}_{1} excited state which decays directly into the ground state. Its angular distribution will be discussed in Sec. 7.2. Above the neutron separation threshold Sn=10.69S_n = 10.69 MeV [57], an increase of events with photon energies less than 2 MeV is observed originating from γ\gamma decays of the 95Ru{}^{95}\mathrm{Ru} daughter in the 96Ru(e,e′nγ){}^{96}\mathrm{Ru}(e,e'\mathrm{n}\gamma) reaction. This will be further discussed in § 10.3. Additionally, the mixed-symmetric 23+2^{+}_{3} state can be seen whose branching ratio will be investigated in § 10.4.

Correction for Coincident Bremsstrahlung

The remaining background in the ExE_x-EγE_{\gamma} matrices in Figure 18 originates from coincident bremsstrahlung events. In this section two methods for the subtraction of the coincident bremsstrahlung contribution from the experimental results are discussed. More details can be found in [58].

Simulation-based corrections

The first procedure utilizes response simulations of the LaBr3_3:Ce detectors in combination with PWBA calculations of the bremsstrahlung process in (e,e′γ)(e,e'\gamma) reactions to subtract the coincident bremsstrahlung contribution. The angular distribution of bremsstrahlung photons produced by relativistic electrons is focused to forward angles due to the Lorentz boost. The LaBr3_3:Ce detectors are positioned at backward angles relative to the incoming electron beam, where bremsstrahlung is suppressed by 4 to 5 orders of magnitude compared to forward angles, see Figure 3. As a consequence, it is computationally not feasible to simulate the bremsstrahlung process for such kinematics. Therefore, a different approach is used in this work.

In order to take the detector response into account, photons emitted isotropically from the target position and detected with DAGOBERT were simulated using GEANT4 [59, 60, 61] leading to homogeneously distributed events in all LaBr3_3:Ce detectors. The differential cross section of the bremsstrahlung contribution is determined for the same kinematical conditions as in the experiment by PWBA calculations with the Bethe-Heitler formula, Eq. (9). The simulation results are combined for each photon with the PWBA differential cross section calculations to generate bremsstrahlung spectra in each LaBr3_3:Ce detector.

With this procedure, γ\gamma energy spectra of prompt bremsstrahlung can be generated for discrete energies of the bremsstrahlung photons. A continuous ExE_x-EγE_{\gamma} matrix is created from the individual γ\gamma energy spectra of the bremsstrahlung by interpolation. Thereby, the experimental energy resolution of the LaBr3_3:Ce detectors and the QCLAM spectrometer determined from the measurements are taken into account. Finally, the resulting ExE_x-EγE_{\gamma} matrix of the simulated coincident bremsstrahlung in 96Ru(e,e′γ){}^{96}\mathrm{Ru}(e,e'\gamma) reactions is scaled to the measured data and subtracted generating a bremsstrahlung-corrected ExE_x-EγE_{\gamma} matrix shown in Figure 19.

A significant reduction of the background is clearly visible in comparison to Figure 18.

Experiment-based correction

Another method for the correction of coincident bremsstrahlung makes use of the measured data. The procedure is illustrated by way of example for the 21+2^{+}_{1} state of 96Ru{}^{96}\mathrm{Ru} in Figure 20.

Four-panel spectra illustrating the subtraction of bremsstrahlung from measured electron-gamma coincidence spectra

Figure 20. (a) Three gates with a width of −2σ1-2\sigma_{1} and +2σ2+2\sigma_{2} of the electron energy resolution (Table 5) in the measured ExE_{x}-EγE_{\gamma} matrix. Blue: Bremsstrahlung plus nuclear decay of interest. Green and red: Bremsstrahlung plus background nuclear decay. (b) Projected γ\gamma energy spectra of the gates defined in (a). (c) Background spectra shifted to the energy of the excited state. The bremsstrahlung contribution under the γ\gamma decay of 197Au{}^{197}\mathrm{Au} was approximated by a second order polynomial. (d) Comparison of measured γ\gamma spectrum with bremsstrahlung-subtracted spectrum. Below the ground state γ\gamma-decay the Compton edge and continuum is visible down to the detector threshold. Procedure for subtracting bremsstrahlung from the measured (e,e′γ)(e,e'\gamma) spectra for individually resolved states using the decay of the 21+2^{+}_{1} state of 96Ru{}^{96}\mathrm{Ru} as example.

Due to the low density of states, regions in the ExE_{x}-EγE_{\gamma} matrix at small excitation energies can be selected where no excited states are present. Hence, all electron-γ\gamma coincidence events in those regions originate solely from bremsstrahlung. Sections below (green colored band) and above (red colored band) the excitation energy of the 21+2^{+}_{1} state (blue colored band) selected for the analysis are illustrated in Figure 20a. The projected low-energy γ\gamma-ray spectrum is shown in Figure 20b. The spectrum of the ground state decay of the 21+2^{+}_{1} state corresponding to the blue band overlaps with coincident bremsstrahlung. The detector response of the 21+→01+2^{+}_{1} \rightarrow0^{+}_{1} transition is visible down to the electronically set threshold of about 450 keV. The green spectrum shows a bremsstrahlung peak at the corresponding excitation energy and also the decay from a transition in 197Au{}^{197}\mathrm{Au} backing material. In the γ\gamma energy spectrum in red the bremsstrahlung peak is visible too. In addition, contributions from the radiative tail of the 21+→01+2^{+}_{1} \rightarrow0^{+}_{1} decay can be seen. Before subtraction, the γ\gamma-ray spectra obtained from the low-energy gate at ∼650\sim650 keV (green) and the high-energy gate at ∼1000\sim1000 keV (red) have to be shifted to the excitation energy of the 21+2^{+}_{1} state as illustrated in Figure 20c. Within a small excitation-energy region, the bremsstrahlung cross section is expected to be a smooth function of the excitation energy. Thus, the mean value of the two background γ\gamma-ray spectra is used to subtract the bremsstrahlung contribution. In addition, the peak from the γ\gamma decay of 197Au{}^{197}\mathrm{Au} has been removed assuming a second-order polynomial background below the peak structure. Figure 20d shows the final bremsstrahlung-subtracted γ\gamma-ray spectrum of the 21+2^{+}_{1} state. This method is restricted to isolated excited states in regions of low level density, since the background gates need to be free from ground-state γ\gamma-ray decays of excited states.

Results of 96Ru(e,e′γ){}^{96}\mathrm{Ru}(e,e^{\prime}\gamma) Measurement

This chapter deals with the analysis of the first (e,e′γ)(e,e^{\prime}\gamma) experiment at the S-DALINAC conducted on 96Ru{}^{96}\mathrm{Ru}. The corrected ExE_{x}-EγE_{\gamma} matrix is used.

Excited States

The excitation energy spectrum taken from a projection of the ExE_{x}-EγE_{\gamma} matrix onto the ExE_{x}-axis is investigated up to 5.5 MeV. This allows to analyze the excitation of individual states. The spectrum is displayed in Figure 21.

Numerous peaks are observed corresponding to nuclear excitations of 96Ru{}^{96}\mathrm{Ru} or 197Au{}^{197}\mathrm{Au}. For the determination of excitation energies Ex,fitE_{x,\mathrm{fit}} and the number of counts present in each peak, an asymmetric Gaussian function with a radiative high-energy tail is used to approximate the line shape [55]:

y=y0⋅{exp⁡(−ln⁡2⋅(x−x0)2σ12),x≤x0,exp⁡(−ln⁡2⋅(x−x0)2σ22),x0<x≤x0+ησ2,A(B+x−x0)δ,x>x0+ησ2.(19)y=y_{0}\cdot\begin{cases} \exp\left(-\ln2\cdot\frac{(x-x_{0})^{2}}{\sigma_{1}^{2}}\right), & x\leq x_{0},\\ \exp\left(-\ln2\cdot\frac{(x-x_{0})^{2}}{\sigma_{2}^{2}}\right), & x_{0}<x\leq x_{0}+\eta\sigma_{2},\\ \frac{A}{(B+x-x_{0})^{\delta}}, & x>x_{0}+\eta\sigma_{2}. \end{cases} \tag*{(19)}

Here, y0y_{0} indicates the amplitude of the peak and x0x_{0} the position of the maximum of the peak. The parameters σ1,2\sigma_{1,2} describe the widths of the two half Gaussian functions, δ\delta the power-law decay and η\eta specifies the attachment point, with η>1\eta> 1. The parameters AA and BB are defined by:

B=σ2δ−2σ2η2ln⁡22ηln⁡2,(20)B = \frac{\sigma_2\delta- 2\sigma_2\eta^2 \ln2}{2\eta\ln2}, \tag*{(20)}
A=2−η2(σ2η+B)δ.(21)A = 2^{-\eta^2}(\sigma_2\eta+ B)^\delta. \tag*{(21)}

To determine the parameters, a fit of Eq. (19) to clearly identifiable peaks in the electron energy spectrum was performed by assuming a linear background. The line shape parameters are assumed to be independent of excitation energy. The results are summarized in Table 5.

σ1\sigma_1 (keV)σ2\sigma_2 (keV)η\etaδ\delta
36.7(4)49.7(5)1.36(2)1.77(8)

Table 5. Fit parameters for the electron energy spectrum according to Eq. (19) with linear background.

The energy resolution of the QCLAM spectrometer was determined as 86.4(1.0) keV (FWHM).

From the first five fitted excited states an energy recalibration to literature values [62] using a first order polynomial, with a resulting slope of 1.0013(13) and an offset of 10.1(15) keV, was carried out. After the recalibration, the fitted excited states are provided in Table 6.

Ex,fitE_{x,\mathrm{fit}} (keV)Ex,LitE_{x,\mathrm{Lit}} (keV)JiπJ_i^\pi
832.6(23)832.5(1)2+2^+
2276(5)2283.3(2)2+2^+
2578(7)2575.7(4) or. 2578.5(5)2+2^+ or. 1+1^+, 2+2^+, 3+3^+
2658(5)2650(2)3(−)3^{(-)}
2855(6)2851.4(2)(2+,3)(2^+, 3)
3258(9)3261.5(8)2+2^+
4022(6)--
4131(8)--
4251(8)--
4551(9)--
4700(9)--

Table 6. Table of fitted excitations Ex,fitE_{x,\mathrm{fit}} in the electron energy spectrum compared with known excitation energies Ex,LitE_{x,\mathrm{Lit}} [62] and their associated states JiπJ_i^\pi.

11 excited states can be clearly identified below 5.5 MeV. The first excited states are well known from the literature [62]. The most pronounced transition corresponds to the excitation of the 21+2_1^+ state of 96Ru^{96}\mathrm{Ru} at 833 keV, which is analyzed in more detail in the subsequent subsection. Other prominent excited states, which could be identified by comparison with the literature values, are, for example, the mixed symmetric 23+2_3^+ state at 2283.3 keV. This special excited state will be analyzed further in § 10.4. The double peak structure between 2.5 MeV and 2.7 MeV corresponds to a 2+2^+ or rather 1+1^+, 2+2^+, 3+3^+ excited state at the lower edge and the 3(−)3^{(-)} state at the higher edge. Furthermore, another 2+2^+ and spin-3 state could be associated with known excited states. Starting at 4 MeV additional excited states could be identified. Furthermore, at 539 keV the first excited 7/2+7/2^+ state of 197Au^{197}\mathrm{Au} [63] is observed.

Angular Distribution of the 21+→01+2_1^+ \to0_1^+ Decay

Photons emitted in the 96Ru(e,e′γ)^{96}\mathrm{Ru}(e,e'\gamma) reaction were detected with DAGOBERT using the six LaBr3_3:Ce scintillation detectors positioned at different angles. This allows for the measurement of angular distributions of γ\gamma-rays emitted in the decays. …

In PWBA, the angular dependence of the nuclear decay on θ\theta and Φ\Phi is encoded in Eq. (4). Writing out the kinematic factors VV one obtains VI∝sin⁡(θ)cos⁡(Φ)V_I \propto\sin(\theta)\cos(\Phi) and VS∝sin⁡2(θ)cos⁡(2Φ)V_S \propto\sin^2(\theta)\cos(2\Phi). In addition, the generalized form factors WW show a dependence on the Legendre polynomials P(cos⁡(θ))P(\cos(\theta)) and their derivatives. The detailed expressions are given in Appendix § 16.

By gating on the excitation of the 21+2_1^+ state, the characteristic quadrupole pattern of the E2E2 transition to the ground state is observed. PWBA calculations based on Eq. (4) are performed for a comparison with the experimental results and shown in Figure 22. In addition, calculations based on the distorted-wave Born approximation (DWBA) discussed below are displayed.

Figure 22. Angular distribution of the 21+→01+2_1^+ \rightarrow0_1^+ decay in the 96Ru(e,e′γ)^{96}\mathrm{Ru}(e,e'\gamma) reaction. The results are compared to PWBA and DWBA calculations. The data is normalized to the PWBA calculations and given in arbitrary units. The corresponding absolute FEP efficiency ϵFEP\epsilon_{\mathrm{FEP}} corrected γ\gamma energy spectra of the six LaBr3_3:Ce detectors can be seen on top of the angular distribution. The left figure features spectra of the three detectors with the smallest angles θ\theta. The middle figure shows spectra of the two detectors near the maximum of the angular distribution. The right figure depicts the spectrum of the detector with the highest angle θ\theta.

For the 96Ru^{96}\mathrm{Ru} target (Z=44Z = 44), Coulomb distortion effects are non-negligible. A distorted-wave Born approximation theory for the (e,e′γ)(e,e'\gamma) process was presented in Ref. [64], extending a previous model where only the charge contribution to the nuclear excitation was formulated [65]. In this theory, the triple differential cross section is given by

d3σdΩedΩγdω=4π2α2EiEfpfpic7frec12∑σiσf∑λ∣Mfi(1)+Mfibrems∣2(22)\frac{d^3\sigma}{d\Omega_e d\Omega_\gamma d\omega} = \frac{4\pi^2\alpha^2 E_i E_f p_f}{p_i c^7 f_{\mathrm{rec}}} \frac{1}{2} \sum_{\sigma_i \sigma_f} \sum_{\lambda} \left|M_{fi}^{(1)}+M_{fi}^{\mathrm{brems}}\right|^2 \tag*{(22)}

where it is averaged over the spin projection σi\sigma_i of the incoming electron, summed over the spin projection σf\sigma_f of the scattered electron and summed over the photon polarization λ\lambda. The matrix element Mfi(1)M_{fi}^{(1)} accounts for the excitation of the nucleus, followed by radiative decay

Mfi(1)=iZc24πω1ω−Ex+iΓJ/2ΓJradΓJ⋅∑M=−JJAfxdec(M)Axiexc(M)(23)M^{(1)}_{fi}=i\frac{Zc^2}{4\pi\sqrt{\omega}}\frac{1}{\omega-E_x+i\Gamma_J/2}\sqrt{\frac{\Gamma_J^{\mathrm{rad}}}{\Gamma_J}}\cdot\sum_{M=-J}^{J}A^{\mathrm{dec}}_{fx}(M)A^{\mathrm{exc}}_{xi}(M) \tag*{(23)}

where J=2J=2 for a 21+2^{+}_{1} excited state. Since for collision energies above 30 MeV an exact (one-photon exchange) bremsstrahlung theory is not feasible, a relativistic modification of the Bethe-Heitler formula for the bremsstrahlung amplitude MfibremsM^{\mathrm{brems}}_{fi} is used, including a reduction factor by the ground-state charge form factor F0(q⃗−k⃗)F_{0}(\vec{q}-\vec{k}) [28] as well as a recoil factor frecf_{\mathrm{rec}} in the cross sections. Explicit expressions for the excitation and decay amplitudes AxiexcA^{\mathrm{exc}}_{xi} and AfxdecA^{\mathrm{dec}}_{fx} are given in Ref. [64].

Since 96Ru^{96}\mathrm{Ru} has a 0+0^{+} ground state, the charge transition density ϱ2(r)\varrho_{2}(r) and the magnetic transition densities J21(r)J_{21}(r) and J23(r)J_{23}(r) contribute to AxiexcA^{\mathrm{exc}}_{xi}, while only the two magnetic densities determine AfxdecA^{\mathrm{dec}}_{fx} (see Eq. (2.7) in Ref. [64], where a factor (4π)−1/2(4\pi)^{-1/2} is missing). For the ground-state charge distribution a Fermi parametrization [66] with c=5.017c=5.017 fm and a=0.55a=0.55 fm is used in order to reproduce the rms radius, and the code RADIAL [67] is applied for the calculation of the electronic scattering states. The nuclear transition densities are obtained by means of the self-consistent Hartree-Fock plus Random Phase Approximation [68, 69] calculations based on the Skyrme parametrization SkP [70], which provides a reasonable description of low-lying collective excited states.

Figure 23 shows DWBA results for a scattering angle of 47.5∘47.5^\circ. The cross section is averaged over the detector resolution Δω/ω=3%\Delta\omega/\omega=3\%, corresponding to 50 keV (FWHM). Since the line width is negligibly small (ΓJrad=ΓJ=0.162(7)\Gamma^{\mathrm{rad}}_{J}=\Gamma_{J}=0.162(7) meV [71]) compared to the resolution, this averaging modifies the resonance factor in Eq. (23).

Figure 23. Averaged triple differential cross section ⟨d3σdΩedΩγdω⟩Δω\left\langle\frac{d^{3}\sigma}{d\Omega_{e}d\Omega_{\gamma}d\omega}\right\rangle_{\Delta\omega} for 87 MeV electrons scattering from 96Ru^{96}\mathrm{Ru} at an angle of 47.5∘47.5^\circ. Shown is the dependence on the photon angle θk\theta_{k} for φk=180∘\varphi_{k}=180^\circ (——, •), φk=120.6∘\varphi_{k}=120.6^\circ (− − −, ■) and φk=136.1∘\varphi_{k}=136.1^\circ (− · − · −, ⊙), including bremsstrahlung. The lines refer to theoretical calculations and the symbols to measurement data points from the LaBr3_{3}:Ce detectors. The bremsstrahlung angular distribution (for φk=120.6∘\varphi_{k}=120.6^\circ) is also shown (⋯), being slightly higher than the ones for the other two azimuthal angles.

For higher-order theories, the zz-axis is usually chosen along the beam direction, such that the photon angle θk\theta_{k} (the abscissa in Figure 23) is the angle between p⃗i\vec{p}_{i} and k⃗\vec{k}. The azimuthal angle φk\varphi_{k} between k⃗\vec{k} and p⃗f\vec{p}_{f} is chosen such that φk=0∘\varphi_{k}=0^\circ or 180∘180^\circ corresponds to in-plane photon emission. The relation to the angles θ\theta and Φ\Phi of Figure 2 and Table 3 are given by:

φk=arctan⁡sin⁡θsin⁡Φsin⁡θcos⁡δcos⁡Φ−sin⁡δcos⁡θ(24)\varphi_k = \arctan\frac{\sin\theta\sin\Phi}{\sin\theta\cos\delta\cos\Phi- \sin\delta\cos\theta} \tag*{(24)}
θk=arccos⁡(cos⁡δcos⁡θ+sin⁡δsin⁡θcos⁡Φ).(25)\theta_k = \arccos\left(\cos\delta\cos\theta+ \sin\delta\sin\theta\cos\Phi\right). \tag*{(25)}

Angular distributions for three azimuthal angles φk\varphi_k are shown in Figure 23 together with the corresponding experimental data normalized at the datum point of detector 1 (θk=90∘\theta_k = 90^\circ, φk=180∘\varphi_k = 180^\circ). The bremsstrahlung contribution for φk=120.6∘\varphi_k = 120.6^\circ is shown as dashed line. In general it is suppressed by more than two orders of magnitude for angles 90∘≤θk≤145∘90^\circ\leq\theta_k \leq145^\circ. The suppression increases with improved detector resolution Δω\Delta\omega.

The difference between PWBA and DWBA was studied in detail for the (e,e′γ)(e,e'\gamma) process on the 21+2_1^+ state of a 92Zr{}^{92}\mathrm{Zr} target [64], which has a similar nuclear charge number. For scattering angles in the forward hemisphere, the shift of the minima in the photon angular distribution is negligibly small, while the intensity increases by about a factor of 1.5. A similar factor enhancing DWBA over PWBA is expected for 96Ru{}^{96}\mathrm{Ru}.

Excellent agreement between the data and the calculations of the angular distribution of the 21+→01+2_1^+ \to0_1^+ transitions of 96Ru{}^{96}\mathrm{Ru} is visible in Figure 22 and Figure 23. In this context it should be pointed out that in Figure 22 the experimental data and the DWBA calculations are normalized to the maximum of the PWBA curve and the cross sections are given in arbitrary units. Hence, the mentioned difference in the calculated intensities between DWBA and PWBA are not shown.

Gamma Decays above Neutron Separation Threshold

A further potential of the newly established (e,e′γ)(e,e'\gamma) setup is the study of γ\gamma-ray decay following (e,e′n)(e,e'n) reactions above the neutron separation threshold. In the ExE_x-EγE_\gamma matrix (compare Figure 18), an increase in events with γ\gamma-ray energies less than 2 MeV is observed for excitation energies above the neutron separation threshold Sn=10.69S_n = 10.69 MeV [57]. Figure 24 presents a γ\gamma-ray spectrum obtained from a projection of the ExE_x-EγE_\gamma matrix limiting the excitation energy to values above SnS_n.

Figure 24. Depopulation of low-lying states of 95Ru{}^{95}\mathrm{Ru} excited in the 96Ru(e,e′nγ){}^{96}\mathrm{Ru}(e,e'n\gamma) reaction above the neutron separation threshold.

Three peaks at energies of 788 keV, 942 keV, and 1141 keV are visible, which can be assigned to the depopulation of the first three excited states of 95Ru{}^{95}\mathrm{Ru} [72]. The 1141 keV γ\gamma transition has been observed for the first time.

Branching Ratio of 23+2^{+}_{3} Excited State

The first analysis of an off-yrast state with (e,e′γ)(e,e'\gamma) reaction was possible in the 96Ru^{96}\mathrm{Ru} experiment. In Figure 21 the excitation of the 23+2^{+}_{3} state at 2.283 MeV is observed, which is known to be a mixed-symmetric state [52, 62, 71]. Its signature is a strong M1M1 transition to the 21+2^{+}_{1} state and a weak E2E2 transition to the ground state. The ground state decay can be used to test the methods for subtraction of coherent bremsstrahlung discussed in § 9.5. Figure 25 presents the γ\gamma-ray spectra gated on the excitation of the 23+2^{+}_{3} state after the bremsstrahlung correction based on simulation and measurement, respectively.

(a) Bremsstrahlung subtraction based on the simulation method, Sec. 6.6.1.

(b) Bremsstrahlung subtraction based on the measurement method, Sec. 6.6.2.

Figure 25. Comparison of the γ\gamma-energy spectra of the 23+2^{+}_{3} excited state of 96Ru^{96}\mathrm{Ru}.

In Figure 25a the γ\gamma-ray spectrum after bremsstrahlung correction based on the simulation method, § 9.5.1, can be seen. The decay of the 23+2^{+}_{3} state into the first excited 21+2^{+}_{1} state and its subsequent decay into the ground state (21+→01+2^{+}_{1} \rightarrow0^{+}_{1}) are clearly visible on top of the Compton continuum of the two decays. Below 400 keV, an oversubtraction of the bremsstrahlung background is recognizable due to the threshold of the LaBr3_{3}:Ce scintillation detectors. After subtraction of the coincident bremsstrahlung, it is difficult to recognize a ground state decay of the 23+2^{+}_{3} state. Hence, an upper limit can be determined, only. A similar result is obtained by subtracting the bremsstrahlung with the measurement method, § 9.5.2, as shown in Figure 25b.

From these spectra the branching ratios are extracted and compared with values from the literature [62] in Table 7.

γ\gamma decayBRLitBR_{\mathrm{Lit}} (%)BRSub,SimBR_{\mathrm{Sub, Sim}} (%)BRSub,MeasBR_{\mathrm{Sub, Meas}} (%)
23+→01+2^{+}_{3} \rightarrow0^{+}_{1}6.7(8)6.1−6.1+1.16.1^{+1.1}_{-6.1}6.0−6.0+2.06.0^{+2.0}_{-6.0}
23+→21+2^{+}_{3} \rightarrow2^{+}_{1}93(10)90(11)90(10)

Table 7. Comparison of the literature values for the branching ratios BRLitBR_{\mathrm{Lit}} of the 23+2^{+}_{3} state [62] with the results from the present work with subtraction of the bremsstrahlung by the simulation BRSub,SimBR_{\mathrm{Sub, Sim}}, § 9.5.1, and measurement BRSub,MeasBR_{\mathrm{Sub, Meas}}, § 9.5.2.

The two methods presented for bremsstrahlung subtraction are compatible with the literature values [62]. This confirms the functionality of the subtraction.

Summary and Outlook

The (e,e′γ)(e,e'\gamma) experimental setup DAGOBERT@QCLAM at the S-DALINAC of the Technische Universität Darmstadt represents a unique device for nuclear structure studies with electron scattering. Compared to the pioneering experiments of Ref. [13, 14], the electro-photo production coincidence resolution R\mathcal{R} of the DAGOBERT@QCLAM set-up could be increased by a factor of about 60. DAGOBERT@QCLAM is capable of measuring angular distributions of nuclear transitions as demonstrated for the 21+2^{+}_{1} state in 96Ru{}^{96}\mathrm{Ru}. Also, branching ratios can be determined as illustrated for the mixed-symmetric 23+2^{+}_{3} state. This represents the first (e,e′γ)(e,e'\gamma) data on an off-yrast nuclear state. Furthermore, (e,e′nγ)(e,e'n\gamma) data above SnS_n were extracted for 96Ru{}^{96}\mathrm{Ru}, where three γ\gamma decays of 95Ru{}^{95}\mathrm{Ru} could be resolved. The first successful (e,e′γ)(e,e'\gamma) study of an A≥90A \ge90 nucleus indicates that experiments are now possible for heavy nuclei as well. A decisive step for increased sensitivity is the subtraction of the coincident bremsstrahlung contributions. Two possible subtraction methods were presented and demonstrated in the analysis of the mixed-symmetric 23+2^{+}_{3} state of 96Ru{}^{96}\mathrm{Ru}.

Overall, DAGOBERT@QCLAM is now ready for science production. Projects underway with the setup include the following. Near the neutron separation threshold, the low-energy dipole response can be investigated with (e,e′γ)(e,e'\gamma) experiments analog to particle-γ\gamma coincidence experiments [73, 74] to select dipole transitions to the ground state, to study the Pygmy Dipole Resonance (PDR) [75, 76] and the toroidal electric dipole mode [77, 78, 79, 80, 81]. Furthermore, a complete separation of M1M1 and E1E1 excitation strength distributions will be feasible by comparing results of nuclear resonance fluorescence (NRF) experiments with polarized photon beams and (e,e′γ)(e,e'\gamma) experiments. Finally, energy-resolved studies of the neutron-decay branches of the Isovector Giant Dipole Resonance (GDR) with (e,e′nγ)(e,e'n\gamma) experiments as function of the excitation energy similar to [82] are planned as future projects exploiting the DAGOBERT setup.

CRediT authorship contribution statement

B. Hesbacher: Methodology, Software, Validation, Formal analysis, Data Curation, Writing - Original Draft, Visualization. G. Steinhilber: Methodology, Software, Validation, Formal analysis, Investigation, Data Curation, Writing - Review & Editing, Visualization. J. Isaak: Methodology, Validation, Investigation, Resources, Data Curation, Writing - Original Draft, Supervision. N. Pietralla: Conceptualization, Methodology, Resources, Writing - Review & Editing, Supervision, Project administration, Funding acquisition. J. Birkhan: Investigation, Writing - Review & Editing, Supervision. I. Brandherm: Investigation, Writing - Review & Editing. M. L. Cortés: Investigation, Writing - Review & Editing. D. H. Jakubassa-Amundsen: Formal analysis, Writing - Review & Editing, Visualization. I. Jurosevic: Investigation, Writing - Review & Editing. P. von Neumann-Cosel: Writing - Review & Editing. M. Rech: Investigation, Writing - Review & Editing. X. Roca-Maza: Formal analysis, Writing - Review & Editing. D. Schneider: Resources, Writing - Review & Editing.

Declaration of competing interest

The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Acknowledgments

We thank the accelerator group of the S-DALINAC and the technical staff at the Institute for Nuclear Physics at Technische Universität Darmstadt for their support. This work is funded by the Deutsche Forschungsgemeinschaft (DFG, German Research Foundation) under project-ID No. 279384907 - SFB 1245 and project-ID No. 499256822 - GRK 2891 ”Nuclear Photonics”. The authors acknowledge the support by the State of Hesse within the Research Cluster ELEMENTS (Project ID 500/10.006). X. Roca-Maza acknowledges support by MICIU/AEI/10.13039/501100011033 and by FEDER UE through grants PID2023-147112NB-C22; and through the “Unit of Excellence María de Maeztu 2020-2023” award to the Institute of Cosmos Sciences, grant CEX2019-000918-M. Additional support is provided by the Generalitat de Catalunya (AGAUR) through grant 2021SGR01095.

Data availability

The processed data underlying this work is openly available at the TUdatalib repository of Technische Universität Darmstadt [83].

Nuclear part of differential cross section of the (e,e′γ)(e,e'\gamma) reaction in PWBA

The differential (e,e′γ)(e,e'\gamma) cross section for a nuclear excitation of a spin-zero ground state with subsequent γ\gamma decay is described in Plane-Wave-Born-Approximation (PWBA) by [29]

d3σnucldΩedΩγdω=2(Zαℏc4π)2(2J+1)⋅pfpiΓJradΓJΓJ(Ex−ω)2+ΓJ24⋅(VLWL+VTWT+VIWI+VSWS),(26)\frac{\mathrm{d}^{3}\sigma_{\mathrm{nucl}}}{\mathrm{d}\Omega_{e}\mathrm{d}\Omega_{\gamma}\mathrm{d}\omega} =2\left(\frac{Z\alpha\hbar c}{4\pi}\right)^{2}(2J+1)\cdot\frac{p_{f}}{p_{i}}\frac{\Gamma^{\mathrm{rad}}_{J}}{\Gamma_{J}}\frac{\Gamma_{J}}{(E_{x}-\omega)^{2}+\frac{\Gamma_{J}^{2}}{4}}\cdot\left(V_{L}W_{L}+V_{T}W_{T}+V_{I}W_{I}+V_{S}W_{S}\right), \tag*{(26)}

using the charge number of the excited nucleus ZZ, the spin of the excited state JJ, the momentum of the scattered electron pfp_{f}, the initial electron momentum pip_{i}, the partial width for the photon decay of the excited state ΓJrad\Gamma^{\mathrm{rad}}_{J}, the total width of the excited state ΓJ\Gamma_{J}, the energy of the excited state ExE_{x}, the energy loss of the electron ω\omega and a sum of products of kinematic factors VV and generalized form factors WW. The meanings of the indices are LL for longitudinal, TT for transversal, II for interference and SS for spin.

The kinematic factors VV can be expressed by:

VL=(Ei+Ef)2−q~2c2q4c4,(27)V_{L}=\frac{(E_{i}+E_{f})^{2}-\tilde{q}^{2}c^{2}}{q^{4}c^{4}}, \tag*{(27)}
VT=2(p⃗i×p⃗f)2+q2q~2q2q~2c2=2(pipfsin⁡(θSpec))2+q2q~2q2q~2c2,(28)V_{T}=\frac{2(\vec{p}_{i}\times\vec{p}_{f})^{2}+q^{2}\tilde{q}^{2}}{q^{2}\tilde{q}^{2}c^{2}}=\frac{2(p_{i}p_{f}\sin(\theta_{\mathrm{Spec}}))^{2}+q^{2}\tilde{q}^{2}}{q^{2}\tilde{q}^{2}c^{2}}, \tag*{(28)}
VI=4(Ei+Ef)(k⃗×q⃗)(p⃗f×p⃗i)ωq4q~2c2=4(Ei+Ef)pipfsin⁡(θ)sin⁡(θSpec)cos⁡(Φ)q3q~2c2,(29)V_{I}=\frac{4(E_{i}+E_{f})(\vec{k}\times\vec{q})(\vec{p}_{f}\times\vec{p}_{i})}{\omega q^{4}\tilde{q}^{2}c^{2}}=\frac{4(E_{i}+E_{f})p_{i}p_{f}\sin(\theta)\sin(\theta_{\mathrm{Spec}})\cos(\Phi)}{q^{3}\tilde{q}^{2}c^{2}}, \tag*{(29)}
VS=2(2((k⃗×q⃗)(p⃗f×p⃗i))2−(k⃗×q⃗)2(p⃗f×p⃗i)2)ω2q4q~4c4=2(pipfsin⁡(θ)sin⁡(θSpec))2cos⁡(2Φ)q2q~4c4.(30)V_{S}=\frac{2\left(2((\vec{k}\times\vec{q})(\vec{p}_{f}\times\vec{p}_{i}))^{2}-(\vec{k}\times\vec{q})^{2}(\vec{p}_{f}\times\vec{p}_{i})^{2}\right)}{\omega^{2}q^{4}\tilde{q}^{4}c^{4}}=\frac{2(p_{i}p_{f}\sin(\theta)\sin(\theta_{\mathrm{Spec}}))^{2}\cos(2\Phi)}{q^{2}\tilde{q}^{4}c^{4}}. \tag*{(30)}

Here EiE_{i} represents the energy of the inital electron, EfE_{f} the energy of the scattered electron, qq the momentum transfer of the electron and kk the momentum of the emitted photon. The underlying coordinate system described by angles θ\theta, θSpec\theta_{\mathrm{Spec}} and Φ\Phi is displayed in Figure 2. Four vectors are denoted by x~\tilde{x}, three vectors by x⃗\vec{x} and the magnitude of the three vectors by xx.

The generalized form factors WW are given by:

WL=−∣FL(q)∣2⋅∑l=0,2,…C1,−1J,J,lC0,0J,J,lPl(cos⁡(θ)),(31)W_{L}=-|F_{L}(q)|^{2}\cdot\sum_{l=0,2,\ldots}C^{J,J,l}_{1,-1}C^{J,J,l}_{0,0}P_{l}(\cos(\theta)), \tag*{(31)}
WT=∣FT(q)∣2⋅∑l=0,2,…(C1,−1J,J,l)2Pl(cos⁡(θ)),(32)W_{T}=|F_{T}(q)|^{2}\cdot\sum_{l=0,2,\ldots}\left(C^{J,J,l}_{1,-1}\right)^{2}P_{l}(\cos(\theta)), \tag*{(32)}
WI=−FL(q)⋅FT(q)⋅∑l=2,4,…C1,−1J,J,lC0,1J,J,l(l(l+1))1/2Pl′(cos⁡(θ)),(33)W_{I}=-F_{L}(q)\cdot F_{T}(q)\cdot\sum_{l=2,4,\ldots}C^{J,J,l}_{1,-1}C^{J,J,l}_{0,1}\left(l(l+1)\right)^{1/2}P'_{l}(\cos(\theta)), \tag*{(33)}
WS=−s(Π)⋅∣FT(q)∣2⋅∑l=2,4,…C1,−1J,J,lC1,1J,J,l((l−2)!(l+1)!)1/2Pl′′(cos⁡(θ)).(34)W_{S}=-s(\Pi)\cdot|F_{T}(q)|^{2}\cdot\sum_{l=2,4,\ldots}C^{J,J,l}_{1,-1}C^{J,J,l}_{1,1}\left(\frac{(l-2)!}{(l+1)!}\right)^{1/2}P''_{l}(\cos(\theta)). \tag*{(34)}

Here, FLF_{L} and FTF_{T} are the longitudinal and transverse form factors of the nucleus. Pl(x)P_{l}(x), Pl′(x)P'_{l}(x) and Pl′′(x)P''_{l}(x) represent Legendre polynomials and their first and second derivatives. The Clebsch-Gordan coefficient for the coupling of ∣j1,m1⟩|j_{1},m_{1}\rangle and ∣j2,m2⟩|j_{2},m_{2}\rangle to ∣J,M⟩|J,M\rangle is given by Cm1,m2j1,j2,JC^{j_{1},j_{2},J}_{m_{1},m_{2}}. The function s(Π)s(\Pi) is +1+1 for an electric transition and −1-1 for a magnetic transition.

References

  1. [1]R. Hofstadter, Electron Scattering and Nuclear Structure, Rev. Mod. Phys. 28 (1956) 214–254.DOI
  2. [2]R. Hahn, D. G. Ravenhall, R. Hofstadter, High-Energy Electron Scattering and the Charge Distributions of Selected Nuclei, Phys. Rev. 101 (1956) 1131–1142.
  3. [3]R. Hofstadter, The Electron-Scattering Method and its Application to the Structure of Nuclei and Nucleons, Nobel Lecture (1961).
  4. [4]T. W. Donnelly, I. Sick, Elastic magnetic electron scattering from nuclei, Rev. Mod. Phys. 56 (1984) 461–566.DOI
  5. [5]B. W. Downs, D. G. Ravenhall, D. R. Yennie, Electron Scattering from Nonspherical Nuclei, Phys. Rev. 106 (1957) 1285–1289.DOI
  6. [6]M. K. Pal, Electron Scattering by the Quadrupole Charge Distribution of N14, Phys. Rev. 117 (1960) 566–572.DOI
  7. [7]J. Goldemberg, R. H. Pratt, Magnetic Electron Scattering from Nuclei, Rev. Mod. Phys. 38 (1966) 311–329.DOI
  8. [8]T. A. Griffy, R. J. Qakes, Electron-Proton Coincidence Cross Section for He3 and H3, Phys. Rev. 135 (1964) B1161–B1167.DOI
  9. [9]R. Hofstadter, Structure of Nuclei and Nucleons, Science 136 (1962) 1013–1022.pubmed.ncbi.nlm.nih.gov/17811003
  10. [10]W. C. Barber, Inelastic Electron Scattering, Annu. Rev. Nucl. Part. Sci. 12 (1962) 1–42.DOI
  11. [11]R. Pitthan, T. Walcher, Inelastic electron scattering in the giant resonance region of La, Ce and Pr, Phys. Lett. B 36 (1971) 563–564.DOI
  12. [12]J. Heisenberg, Nuclear transition density determinations from inelastic electron scattering, Adv. Nucl. Phys. 12 (1981) 61–133.DOI
  13. [13]C. N. Papanicolas, Low energy experiments with continuous electron and photon beams, Nucl. Phys. A 446 (1989) 249–258.
  14. [14]C. N. Papanicolas, S. E. Williamson, H. Rothhaas, G. O. Bolme, L. J. Koester, Jr., B. L. Miller, R. A. Miskimen, P. E. Mueller, and L. S. Cardman, (e,e′γ) Measurements of the 4.439-MeV State of 12C, Phys. Rev. Lett. 54 (1985) 26–29.pubmed.ncbi.nlm.nih.gov/10030875
  15. [15]P. E. Mueller, Separation of the E2 and M1 form factors of the 6.32 MeV state of nitrogen-15 using (e,e’gamma), Ph.D. Thesis, University of Illinois, Illinois, 1993.
  16. [16]J. R. Deininger, Nuclear structure in oxygen-16 measured with (e,e’gamma) coincident electron scattering, Ph.D. Thesis, University of Illinois, Illinois, 1996.
  17. [17]N. Pietralla, The Institute of Nuclear Physics at the TU Darmstadt, Nucl. Phys. News 28 (2018) 4–11.DOI
  18. [18]A. D’Alessio, P. von Neumann-Cosel, N. Pietralla, M. Singer, W. Werner, The QClam-Spectrometer at the S-DALINAC, in: J.-E. García-Ramos, M. V. Andrés, J. A. L. Valera, A. M. Moro, F. Pérez-Bernal (Eds.), Basic Concepts in Nuclear Physics: Theory, Experiments and Applications, Springer International Publishing, Cham, 2019, pp. 189–190.
  19. [19]B. Rasmussen, BrilLance 380 Scintillation Material, 2004.
  20. [20]P. Dirac, The quantum theory of the emission and absorption of radiation, Proc. R. Soc. Lond. A 114 (1927) 243–265.
  21. [21]T. de Forest, J. D. Walecka, Electron scattering and nuclear structure, Adv. Phys. 15 (1966) 1–109.DOI
  22. [22]H. Überall, Electron Scattering from Complex Nuclei: Part B, volume 2, Academic Press, New York, 1971.DOI
  23. [23]T. Suda, H. Simon, Prospects for electron scattering on unstable, exotic nuclei, Prog. Part. Nucl. Phys. 96 (2017) 1–31.DOI
  24. [24]P. von Neumann-Cosel, C. Rangacharyulu, A. Richter, G. Schrieder, A. Staschek, S. Strauch, Complete Spectroscopy of an Isobaric Analog Resonance with the (e,e′p) Reaction, Phys. Rev. Lett. 78 (1997) 2924–2927.
  25. [25]H. Diesener, U. Helm, P. von Neumann-Cosel, A. Richter, G. Schrieder, S. Strauch, Isoscalar multipole strength decomposition in 40Ca with the (e,e′α0) reaction, Phys. Lett. B 352 (1995) 201–206.DOI
  26. [26]P. von Neumann-Cosel, H. Diesener, U. Helm, G. Herbert, V. Huck, A. Richter, G. Schrieder, A. Staschek, A. Stiller, J. Ryckebusch, J. Carter, A. Cowley, R. Fearick, J. Lawrie, S. Mills, R. Newman, J. Pilcher, F. Smit, Z. Vilakazi, D. Whittal, Excitation and decay of electric giant resonances in the 40Ca(e,e′x) and 40Ca(p,p′x) reactions, Nucl. Phys. A 569 (1994) 373–382.
  27. [27]S. Strauch, P. von Neumann-Cosel, C. Rangacharyulu, A. Richter, G. Schrieder, K. Scheweda, J. Wambach, Giant Resonances in the Doubly Magic Nucleus 48Ca from the (e,e′n) Reaction, Phys. Rev. Lett. 85 (2000) 2913–2916.pubmed.ncbi.nlm.nih.gov/11005966
  28. [28]D. F. Hubbard, M. E. Rose, Nuclear structure effects in bremsstrahlung, Nucl. Phys. 84 (1966) 337–379.DOI
  29. [29]H. L. Acker, M. E. Rose, Investigation of Nuclear Effects in Bremsstrahlung, Ann. Phys. 44 (1967) 336–362.DOI
  30. [30]T. Donnelly, Electron scattering and neutrino reactions in nuclei, Prog. Part. Nucl. Phys. 13 (1985) 183–236.DOI
  31. [31]H. Bethe, W. Heitler, On the stopping of fast particles and on the creation of positive electrons, Proc. R. soc. Lond. Ser. A-Contain. Pap. Math. Phys. Character 161 (1934) 83–112.
  32. [32]K. Sonnabend, D. Savran, J. Beller, M. A. Büssing, A. Constantinescu, M. Elvers, J. Endres, M. Fritzsche, J. Glorius, J. Hasper, J. Isaak, B. Löher, S. Müller, N. Pietralla, C. Romig, A. Sauerwein, L. Schnorrenberger, C. Wälzlein, A. Zilges, M. Zweidinger, The Darmstadt High-Intensity Photon Setup (DHIPS) at the S-DALINAC, Nucl. Instrum. Methods Phys. Res. A 640 (2011) 6–12.DOI
  33. [33]M. G. Meier, Entwicklung und Aufbau der Laser-getriebenen Compton-Rückstreuquelle COBRA für Strahldiagnose am S-DALINAC, Doctoral Thesis, Technische Universität Darmstadt, Darmstadt, 2024.DOI
  34. [34]D. Savran, K. Lindenberg, J. Glorius, B. Löher, S. Müller, N. Pietralla, L. Schnorrenberger, V. Simon, K. Sonnabend, C. Wälzlein, M. Elvers, J. Endres, J. Hasper, A. Zilges, The low-energy photon tagger NEPTUN, Nucl. Instrum. Methods Phys. Res. A 613 (2010) 232–239.DOI
  35. [35]M. Knirsch, Konzeption, Aufbau und Erprobung eines hochauflösenden QCLAM-Elektronenspektrometers mit großem Raumwinkel und hoher Impulsakzeptanz am Elektronenbeschleuniger S-DALINAC, Doctoral Thesis, Technische Hochschule Darmstadt, Darmstadt, 1991.
  36. [36]G. C. Lüttge, Entwicklung und Aufbau eines Magnetsystems für Elektronenstreuung unter 180° und vollständige Bestimmung der magnetischen Dipol- und Quadrupolstärkeverteilung in 28Si, Doctoral Thesis, Technische Hochschule Darmstadt, Darmstadt, 1994.
  37. [37]D. Schüll, J. Foh, H.-D. Gräf, H. Miska, R. Schneider, E. Spamer, H. Theissen, O. Titze, T. Walcher, High resolution electron scattering facility at the Darmstadt linear accelerator (DALINAC): III. Detector system and performance of the electron scattering apparatus, Nucl. Instrum. and Methods 153 (1978) 29–41.
  38. [38]M. Singer, U. Bonnes, A. D’Alessio, M. Hilcker, P. von Neumann-Cosel, N. Pietralla, New data acquisition system of the Lintott magnetic spectrometer at the S-DALINAC, Nucl. Instrum. Methods Phys. Res. A 999 (2021) 165115.DOI
  39. [39]L. Jürgensen, Entwicklung und Aufbau eines Hochenergie-Elektronen-Scrapersystems für den S-DALINAC, Doctoral Thesis, Technische Universität Darmstadt, Darmstadt, 2018.DOI
  40. [40]K.-D. Hummel, Entwicklung Aufbau und Inbetriebnahme eines Vielstrahlfilterkammer-Detektorsystems für das QCLAM-Spektrometer am supraleitenden Darmstädter Elektronenbeschleuniger S-DALINAC, Doctoral Thesis, Technische Hochschule Darmstadt, Darmstadt, 1992.
  41. [41]F. Neumeyer, Untersuchung magnetischer Kernanregungen in 48Ca und 90Zr mit hochauflösender Elektronenstreuung unter 180° am S-DALINAC, Doctoral Thesis, Technische Universität Darmstadt, Darmstadt, 1997.
  42. [42]M. Singer, Entwicklung und Inbetriebnahme eines neuen Datenaufnahmesystems am QCLAM-Spektrometer, Doctoral Thesis, Technische Universität Darmstadt, Darmstadt, 2019.DOI
  43. [43]G. Steinhilber, The electron-gamma coincidence setup at the S-DALINAC, Doctoral Thesis, Technische Universität Darmstadt, Darmstadt, 2022.DOI
  44. [44]D. Schneider, M. Arnold, U. Bonnes, A. Brauch, M. Dutine, R. Grewe, L. E. Jürgensen, N. Pietralla, F. Schließmann, G. Steinhilber, Development of an active beam-stabilization system for electroission experiments at the S-DALINAC, in: Proc. IPAC’24, 15th International Particle Accelerator Conference, 2024, pp. 2411–2414.DOI
  45. [45]Saint-Gobain Crystals, Scintillation Products Technical Note - Lanthanum Bromide Scintillation Performance Summary, 2021.
  46. [46]B. Löhrer, D. Savran, E. Fiori, M. Miklavcic, N. Pietralla, M. Vencelj, High count rate γ-ray spectroscopy with LaBr3:Ce scintillation detectors, Nucl. Instrum. Methods Phys. Res. A 686 (2012) 1–6.
  47. [47]Dassault Systèmes, CST Studio Suite 2020.00 - release notes, 2019.
  48. [48]E. L. Goldwasser, F. E. Mills, A. O. Hanson, Ionization Loss and Straggling of Fast Electrons, Phys. Rev. 88 (1952) 1137–1141.DOI
  49. [49]GSI Helmholzzentrum für Schwerionenforschung GmbH, GSI multi branch system, 22.10.2020. URL: https://web.archive.org/web/20201022154112/https://www.gsi.de/work/forschung/experimentelektronik/datenverarbeitung/datenerfassung/ mbs.htm.
  50. [50]Struck Innovative Systems GmbH, SIS3316 16 channel 125/250 MSPS 14/16-bit Digitizer Family, 2024. URL: https://www.struck.de/ sis3316.html.
  51. [51]H. T. Johansson, The UCESB unpacker generator, 2010. URL: http://fy.chalmers.se/~f96hajo/ucesb/.
  52. [52]N. Pietralla, C. J. Barton, R. Krücken, C. W. Beausang, M. A. Caprio, R. F. Casten, J. R. Cooper, A. A. Hecht, H. Newman, J. R. Novak, N. Zamfir, Coulomb excitation of the 2+ state of 96Ru in inverse kinematics, Phys. Rev. C 64 (2001) 031301(R).
  53. [53]H. Foyle, On Nuclear Reactions Occurring in Very Hot STARS.I. the Synthesis of Elements from Carbon to Nickel, Astrophys. J. Suppl. Ser. 1 (1954) 121.
  54. [54]J. H. Kelley, J. E. Purcell, C. G. Sheu, Energy levels of light nuclei A = 12, Nucl. Phys. A 968 (2017) 71–253.DOI
  55. [55]F. Hofmann, P. von Neumann-Cosel, F. Neumeyer, C. R. R. Rauscher, B. Reitz, A. Richter, G. Schrieder, D. I. Sober, L. W. Fagg, B. A. Brown, Magnetic dipole transitions in 32S from electron scattering at 180°, Phys. Rev. C 65 (2002) 024311.
  56. [56]R. Helmer, C. van der Leun, Recommended standards for γ-ray energy calibration (1999), Nucl. Instrum. Methods Phys. Res. A 450 (2000) 35–70.
  57. [57]M. Wang, G. Audi, A. Wapstra, F. Kondev, M. MacCormick, X. Xu, B. Pfeiffer, The Ame2012 atomic mass evaluation, Chin. Phys. C 36 (2012) 1603.
  58. [58]B. Hesbacher, Kernstrukturuntersuchungen an 96Ru mittels Elektron-Gamma-Koinzidenz-Reaktionen am S-DALINAC, M.Sc. Thesis, Technische Universität Darmstadt, Darmstadt, 2023.
  59. [59]J. Allison, K. Amako, J. Apostolakis, P. Arce, M. Asai, T. Aso, E. Bagli, A. Bagulya, S. Banerjee, G. Barrand, B. Beck, A. Bogdanov, D. Brandt, J. Brown, H. Burkhardt, P. Canal, D. Cano-Ott, S. Chauvie, K. Cho, G. Cirrone, G. Cooperman, M. Cortés-Galvdo, G. Cosmo, G. Cuttone, G. Depaola, L. Desorgher, X. Dong, A. Dotti, V. Elvira, G. Folger, Z. Francis, A. Galoyan, L. Garnier, M. Gayer, K. Genser, V. Grichine, S. Guatelli, P. Guèye, P. Gumplinger, A. Howard, I. Hřivnáčová, S. Hwang, S. Incerti, A. Ivanchenko, V. Ivanchenko, F. Jones, S. Jun, P. Kaitaniemi, N. Karakatsanis, M. Karamitros, M. Kelsey, A. Kimura, T. Koi, H. Kurashige, A. Lechner, S. Lee, F. Longo, M. Maire, D. Mancusi, A. Mantero, E. Mendoza, B. Morgan, K. Murakami, T. Nikitina, L. Pandola, P. Paprocki, J. Perl, I. Petrović, M. Pia, W. Pokorski, J. Quesada, M. Raine, M. Reis, A. Ribon, A. Ristić Fira, F. Romano, G. Russo, G. Santin, T. Sasaki, D. Sawkey, J. Shin, I. Strakovsky, A. Taborda, S. Tanaka, B. Tomé, T. Toshito, H. Tran, P. Truscott, L. Urban, V. Uzhinsky, J. Verbeke, M. Verderi, A. Walkden, J. Wellisch, D. Williams, D. Wright, T. Yamashita, J. Yarba, H. Yoshida, Recent developments in Geant4, Nucl. Instrum. Methods Phys. Res. A 835 (2016) 186–225.
  60. [60]J. Allison, K. Amako, J. Apostolakis, H. Araujo, P. Arce Dubois, M. Asai, G. Barrand, R. Capra, S. Chauvie, R. Chytracek, G. Cirrone, G. Cooperman, G. Cosmo, G. Cuttone, G. Daquino, M. Donszelmann, M. Dressel, G. Folger, F. Foppiano, J. Generowicz, V. Grichine, S. Guatelli, P. Gumplinger, A. Heikkinen, I. Hřivnacova, A. Howard, S. Incerti, A. Ivanchenko, V. Ivanchenko, T. Johnson, F. Jones, T. Koi, R. Kokoulin, M. Kossov, H. Kurashige, V. Lara, S. Larsson, F. Lei, O. Link, F. Longo, M. Maire, A. Mantero, B. Mascialino, I. McLaren, P. Mendez Lorenzo, K. Minamimoto, K. Murakami, P. Nieminen, L. Pandola, S. Parlati, L. Peralta, J. Perl, A. Pfeiffer, M. Pia, A. Ribon, P. Rodrigues, G. Russo, S. Sadilov, G. Santin, T. Sasaki, D. Smith, N. Starkov, S. Tanaka, E. Tcherniaev, B. Tome, A. Trindade, P. Truscott, L. Urban, M. Verderi, A. Walkden, J. Wellisch, D. Williams, D. Wright, H. Yoshida, Geant4 developments and applications, IEEE Trans. Nucl. Sci. 53 (2006) 270–278.
  61. [61]S. Agostinelli, J. Allison, K. Amako, J. Apostolakis, H. Araujo, P. Arce, M. Asai, D. Axen, S. Banerjee, G. Barrand, F. Behner, L. Bellagamba, J. Boudreau, L. Broglia, A. Brunengo, H. Burkhardt, S. Chauvie, J. Chuma, R. Chytracek, G. Cooperman, G. Cosmo, P. Degtyarenko, A. Dell’Acqua, G. Depaola, D. Dietrich, R. Enami, A. Feliciello, C. Ferguson, H. Fesefeldt, G. Folger, F. Foppiano, A. Forti, S. Garelli, S. Giani, R. Giannitrapani, D. Gibin, J. Gómez Cadenas, I. González, G. Gracia Abril, G. Grein, W. Greiner, V. Grichine, A. Grossheim, S. Guatelli, P. Gumplinger, R. Hamattsu, K. Hashimoto, H. Hasui, A. Heikkinen, A. Howard, V. Ivanchenko, A. Johnson, F. Jones, J. Kallenbach, N. Kanaya, M. Kawabata, Y. Kawabata, M. Kawaguti, S. Kelner, P. Kent, A. Kimura, T. Kodama, R. Kokoulin, M. Kossov, H. Kurashige, E. Lamanna, T. Lampén, V. Lara, V. Lefebure, F. Lei, M. Liendl, W. Lockman, F. Longo, S. Magni, M. Maire, E. Medernach, K. Minamimoto, P. Mora de Freitas, Y. Morita, K. Murakami, M. Nagamatu, R. Nartallo, P. Nieminen, T. Nishimura, K. Ohtsubo, M. Okamura, S. O’Neale, Y. Oohata, K. Paech, J. Perl, A. Pfeiffer, M. Pia, F. Ranjard, A. Rybin, S. Sadilov, E. Di Salvo, G. Santin, T. Sasaki, N. Savvas, Y. Sawada, S. Scherer, S. Sei, V. Sirotenko, D. Smith, N. Starkov, H. Stoecker, J. Sulkimo, M. Takahata, S. Tanaka, E. Tcherniaev, E. Safai Tehrani, M. Tropeano, P. Truscott, H. Uno, L. Urban, P. Urban, M. Verderi, A. Walkden, W. Wander, H. Weber, J. Wellich, T. Wenaus, D. Williams, D. Wright, T. Yamada, H. Yoshi da, D. Zschiesche, Gent4t — a simulation toolkit, Nucl. Instrum. Methods Phys. Res. A 506 (2003) 250–303.DOI
  62. [62]A. Hennig, T. Ahn, V. Anagnost atou, A. Blazhev, N. Cooper, V. Derya, M. Elvers, J. Endres, P. Goddard, A. Heinz, R. O. Hughes, G. Ilie, M. N. Mineva, P. Petkov, S. G. Pickstone, N. Pietralla, D. Radeck, T. J. Ross, D. Savran, M. Spieker, V. Werner, A. Zilges, Collective excitations of 96Ru by means of (p,p′) experiments, Phys. Rev. C 92 (2015) 064317.
  63. [63]H. Bolotin, D. Kennedy, B. Linard, A. Stuchbery, S. Sie, I. Katayama, H. Sakai, Measured lifetimes of states in 197Au and a critical comparison with the weak-coupling core-excitation model, Nucl. Phys. A 321 (1979) 231–249.DOI
  64. [64]D. H. Jakubassa-Amundsen, V. Y. Ponomarev, Coincident excitation and radiative decay in electron-nucleus collisions, Phys. Rev. C 95 (2017) 024310.
  65. [65]D. Ravenhall, R. Schult, J. Wambach, C. Papapicolas, S. Williamson, Coincident electron scattering in distorted wave Born approximation I. The (e,e′γ) process, Ann. Phys. 178 (1987) 187–226.DOI
  66. [66]L. Visscher, K. Dyall, Dirac–Fock atomic electronic structure calculations using different nuclear charge distributions, At. Data Nucl. Data Tables 67 (1997) 207–224.DOI
  67. [67]F. Salvat, J. Fernández-Varea, W. Williamson, Accurate numerical solution of the radial Schrödinger and Dirac wave equations, Comput. Phys. Commun. 90 (1995) 151–168.DOI
  68. [68]G. Colò, L. Cao, N. Van Giai, L. Capelli, Self-consistent RPA calculations with Skyrme-type interactions: The skyrme_rpa program, Comput. Phys. Commun. 184 (2013) 142–161.DOI
  69. [69]G. Colò, X. Roca-Maza, User guide for the hfbcs-qrpa(v1) code, 2021. arXiv:2102.06562.arxiv.org/abs/2102.06562
  70. [70]J. Dobaczewski, H. Flocard, J. Treiner, Hartree–Fock–Bogolyubov description of nuclei near the neutron-drip line, Nucl. Phys. A 422 (1984) 103–139.DOI
  71. [71]H. Klein, A. F. Lisetskiy, N. Pietralla, C. Fransen, A. Gade, P. von Brentano, Proton-neutron mixed-symmetry 2+ms and 3+ms states in 96Ru, Phys. Rev. C 65 (2002) 044315.
  72. [72]J. Ball, Studies of 95Ru and 94Ru with the 96Ru(p,d) and (p,t) reactions, Nucl. Phys. A 160 (1971) 225–236.DOI
  73. [73]D. Savran, M. Babilon, A. M. van den Berg, M. N. Harakeh, J. H. Asper, A. Matic, H. J. Wörtche, A. Zilges, Nature of the Pygmy Dipole Resonance in 140Ce Studied in (α, α′) Experiments, Phys. Rev. Lett. 97 (2006) 172502.
  74. [74]D. Savran, V. Derya, S. Bagchi, J. Endres, M. Harakeh, J. Isaak, N. Kalantar-Nayestanaki, E. Lanza, B. Löher, A. Najafi, S. Pascu, S. Pickstone, N. Pietralla, V. Ponomarev, C. Rigillet, C. Romig, M. Spieker, A. Vitturi, A. Zilges, Multi-messenger investigation of the Pygmy Dipole Resonance in 140Ce, Phys. Lett. B 786 (2018) 16–20.
  75. [75]D. Savran, T. Aumann, A. Zilges, Experimental studies of the Pygmy Dipole Resonance, Prog. Part. Nucl. Phys. 70 (2013) 210–245.DOI
  76. [76]E. Lanza, L. Pellegri, A. Vitturi, M. Andrés, Theoretical studies of Pygmy Resonances, Prog. Part. Nucl. Phys. 129 (2023) 104006.DOI
  77. [77]S. F. Semenko, Sov. J. Nucl. Phys. 34 (1981).
  78. [78]V. O. Nesterenko, A. Repko, J. Kvasil, P.-G. Reinhard, Individual Low-Energy Toroidal Dipole State in 24Mg, Phys. Rev. Lett. 120 (2018) 182501.DOI
  79. [79]V. O. Nesterenko, A. Repko, J. Kvasil, P.-G. Reinhard, Individual dipole toroidal states: Main features and search in the (e,e′) reaction, Phys. Rev. C 100 (2019) 064302.DOI
  80. [80]A. Repko, V. O. Nesterenko, J. Kvasil, P.-G. Reinhard, Systematics of toroidal dipole modes in Ca, Ni, Zr, and Sn isotopes, Eur. Phys. J. A 55 (2019) 242–257.DOI
  81. [81]P. von Neumann-Cosel, V. O. Nesterenko, I. Brandherm, P. I. Vishnevsky, P.-G. Reinhard, J. Kvasil, H. Matsubara, A. Repko, A. Richter, M. Scheck, A. Tamii, Candidate Toroidal Electric Dipole Mode in the Spherical Nucleus 58Ni, Phys. Rev. Lett. 133 (2024) 232502.
  82. [82]J. Kleemann, N. Pietralla, U. Friman-Gayer, J. Isaak, O. Papst, K. Prifti, V. Werner, A. D. Ayangada, T. Beck, G. Colò, M. L. Cortés, S. W. Finch, M. Fulghieri, D. Gribble, K. E. Ide, X. K.-H. James, R. V. F. Janssens, S. R. Johnson, P. Koseoglou, K. Krichishayan, D. Savran, W. Tornow, Gamma Decay of the 58m Isovector Giant Dipole Resonance: Smekal-Raman Scattering as a Novel Probe of Nuclear Ground-State Deformation, Phys. Rev. Lett. 134 (2025) 022503.
  83. [83]B. Hesbacher, G. Steinhilber, J. Isaak, N. Pietralla, J. Birkhan, I. Brandherm, M. L. Cortes, D. Jakubassa-Amundsen, I. Jurosevic, P. von Neumann-Cosel, M. Rech, X. Roca-Maza, D. Schneider, Dataset for "The Electron-Gamma Coincidence Setup DAGOBERT" Manuscript , 2025. URL: https://doi.org/10.48328/tudatalib–1665.

Paper details

vlnc:W_xmvga56m
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 0

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents