betaFeedback

WorksPhysics and Astronomy

Performance of small-diameter muon drift tube chambers with new fast readout ASIC at high background rates

Abstract

Experiments like ATLAS at the HL-LHC or detectors at future hadron colliders need muon detectors with excellent momentum resolution up to the TeV scale both at the trigger and offline reconstruction levels. This requires muon tracking chambers with high spatial resolution even at the highest background fluxes. Drift-tube chambers are the most cost-effective technology for large-area muon systems, providing the required high rate capability and three-dimensional spatial resolution. Thanks to advances in electronics, the new generation small-diameter Muon Drift Tube (sMDT) detectors with 15 mm tube diameter can be used in stand-alone mode up to the background rates expected at future hadron collider experiments, providing event times and second coordinates without additional trigger chambers. New developments in integrated front-end electronics include fast baseline restoration of the shaped signal and picosecond time-to-digital converters for second coordinate measurement with double-sided read-out. Self-triggered operation is now possible using modern high-performance FPGAs for real-time pattern recognition and track reconstruction. A new amplifier shaper discriminator chip in 65 nm TSMC CMOS technology with increased sensitivity and faster baseline recovery has been developed to cope with high background fluxes. Extensive test beam campaigns using sMDT chambers with new readout electronics have been performed at the CERN Gamma Irradiation Facility (GIF++). Results show that the shorter peaking time of the new chip enhances the spatial resolution of the drift tubes by up to 100 μμm at a background rate of 1 MHz, the maximum rate expected at the 100 TeV collider experiment.

High background rates at Future Circular Hadron Collider (FCC-hh)

In the conceptual design of a detector for a future 100 TeV pp collider (FCC-hh) [1], the muon system surrounds the inner detector’s solenoid magnet and consists of four parts:

  • ∣η∣<1.0|\eta| < 1.0: Barrel muon system

  • 1.0≤∣η∣<1.51.0 \leq|\eta| < 1.5: Outer end-cap muon system

  • 1.5≤∣η∣<2.21.5 \leq|\eta| < 2.2: Inner end-cap muon system

  • 2.2≤∣η∣<3.02.2 \leq|\eta| < 3.0: Forward muon system

Different background hit fluxes are expected in each η\eta-region, with counting rates up to 500 Hz/cm2^2 in the barrel and outer end-cap regions, and up to 10 kHz/cm2^2 or 25 kHz/cm2^2 with a safety factor of 2.5 in the inner end-cap and forward regions.

The muon detector system has two essential functions: providing a muon trigger and achieving ∼10%\sim10\% momentum resolution at 10 TeV muon energy by precise muon track reconstruction with an angular resolution of 70 μrad\mu\mathrm{rad}. This precision is possible with small-diameter drift-tube chambers (sMDT), which can operate effectively at rates up to 30 kHz/cm2^2 with 30% occupancy. sMDT technology, featuring two multilayers of four 15 mm diameter drift tube layers spaced 1.5 m apart, can ensure an angular resolution better than 70 μrad\mu\mathrm{rad} and with the single tube resolution below 150 μm\mu\mathrm{m}. [2].

sMDT detector design and high rate effects

Aluminum sMDT drift tubes have a diameter of 15 mm and a wall thickness of 0.4 mm. They are filled with an Ar/CO2_2 (93/7) gas mixture at 3 bar absolute and are operated at 2730 V, resulting in a nominal gas amplification factor GG of 2×1042 \times10^{4}. [3]

The degradation of spatial resolution and detection efficiency in sMDT detectors at high background hit rates is caused by the following effects [3]:

  • Increased Occupancy: Making it difficult to distinguish individual muon hits from background hits and reducing the spatial resolution due to the pile-up of γ\gamma background and muon hits.

  • Dead Time: Higher likelihood of missed muon events due to new hits occurring during the detector’s dead time, decreasing detection efficiency.

  • Gas Gain Drop and Fluctuations: The presence of positive space charge within a tube from ions created by background hits leads to a reduction of the electric field at the anode wire, hence to a gain drop. This drop can be compensated by increasing the operating voltage. Gain fluctuation caused by fluctuations of the space charge has a negligible impact on the tube’s performance.

In order to mitigate these effects, the sMDT detector must be equipped with improved front-end electronics featuring fast baseline restoration of the shaped signal to handle high rates and reduce dead time.

New 65 nm ASD chip

A four-channel Amplifier/Shaper/Discriminator (ASD) chip, developed by the Max Planck Institute for Physics (Munich) and fabricated using 65 nm TSMC CMOS technology, has been designed to enhance performance at high counting rates in sMDTs.

The ASD chip features bipolar shaping to reduce the effects of baseline shift at high signal rates and has a much faster baseline recovery than the ATLAS ASD chip (Figure 1), reducing the signal pile-up effect. It provides output as both low voltage differential signals and digital CMOS level signals. Each channel consumes 12.8 mW of power, which is 61.2% less than the ATLAS ASD chip used in the HL-LHC phase II. Additionally, each channel occupies just 0.235 mm2^{2}, which is 43% of the area of the current ATLAS ASD chip.

Comparison of the $\delta$ response functions of the new ASD chip and the old ASD chip currently used on ATLAS MDT chambers

Figure 1. Comparison of the δ\delta response functions of the new ASD chip and the old ASD chip currently used on ATLAS MDT chambers.

Performance of the sMDT detector instrumented with the new 65 nm ASD chip at high background rates

The performance of the new chip was tested on an sMDT chamber at the CERN Gamma Irradiation Facility (GIF++) under gamma background irradiation with a high-energy muon beam and compared with the ATLAS chip.

Figure 2 shows the study of the muon detection efficiency for 65 nm ASD and ATLAS ASD chips at the different background counting rate. Without γ\gamma background the muon detection efficiency is less than 100%, namely (99.0±\pm0.6)%. The efficiency decreases with increasing γ\gamma count-rate due to the increasing probability that a γ\gamma hit masks a muon hit within the dead time of the front-end electronics [5]. The efficiency dependence on the γ\gamma background hit rate is compatible with the expectation for 140 ns dead time of the ATLAS ASD chip and 40 ns dead time of the new 65 nm ASD chip, which was achieved by its fast baseline recovery. As a consequence of the small dead time, a very high muon detection efficiency of >92%> 92\% at 1.4 MHz background hit rate is observed.

Particle detection efficiency as a function of the average counting rate per tube

Figure 2. Particle detection efficiency as a function of the average counting rate per tube in kHz without correction for multiplicity. Line of 40 ns dead time (black dashed line) and 140 ns (red dashed line) shown. The dead time of the 65 nm ASD is nearly four times lower than the ATLAS ASD.

Figure 3 summarizes the dependence of the average spatial resolution of an sMDT on the γ\gamma count-rate per tube. The sMDT spatial resolution with the 65 nm ASD chip is compatible with the simulation and is better by 10 μm\mu\mathrm{m} than with the current ATLAS ASD, 85 μm\mu\mathrm{m} without irradiation, and it is expected to be around 110 μm\mu\mathrm{m} for a counting rate of 1 MHz/tube. The degradation of the spatial resolution is totally caused by the pile-up of muon and background hits [5].

Spatial resolution of the 65 nm ASD from test beam measurements, Garfield++ simulation and ATLAS ASD measurements under irradiation

Figure 3. Spatial resolution of the 65 nm ASD from the test beam measurements (black), the Garfield++ simulation (red) and the ATLAS ASD from the test beam measurements (blue) under irradiation. The dashed lines show the fit to the resolution points.

Conclusion

The new 65 nm ASD chip significantly enhances the performance of sMDT chambers under high background rates, providing improved spatial resolution and detection efficiency, making it suitable for future high-energy physics experiments.

References

  1. [1]A. Abada et al., FCC-hh: The hadron collider - future circular collider conceptual design report volume 3, The European Physical Journal Special Topics 228 (2019) 755–1107.
  2. [2]O. Kortner, S. Kortner, H. Kroha, S. Podkladkin, R. Richter, Design of the FCC-hh muon detector and trigger system, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 936 (2019) 447–448, Frontier Detectors for Frontier Physics: 14th Pisa Meeting on Advanced Detectors.DOI
  3. [3]H. Kroha et al., Design and construction of integrated small-diameter drift tube and thin-gap resistive plate chambers for the phase-1 upgrade of the ATLAS muon spectrometer, Nucl. Instrum. Methods Phys. Res., A (2018). doi:10.1016/j.nima.2018.10.139.DOI
  4. [5]N. Bangaru, Design and Testing of Gaseous Detectors and Their Readout Electronics for Particle Detection at High Counting Rates, 2024. CERN-THESIS-2024-048, https://cds.cern.ch/record/2896934?ln=en.

Paper details

vlnc:W_xv4252rx
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 2

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents