Production of Iodine Isotopes via Ultra-intense Laser Driven Photonuclear Reactions

Abstract

The investigation and production of proton-rich iodine isotopes predominantly rely on conventional accelerator-based methods, typically requiring prolonged irradiation periods to measure or achieve quantifiable yields for isotopic isolation. Bremsstrahlung radiation sources generated by high-power laser-plasma-accelerated electron beams with ultrahigh charge (tens of nanocoulombs) bombarding high-Z targets demonstrate extraordinary photon flux characteristics. An electron beam with a total charge of approximately 47.7 nC (Ee_e >\gt 10.4 MeV) was generated in our experiment by focusing a ultra-intense laser pulse onto a deuterium gas jet. Laser-driven bremsstrahlung was employed to induce 127I^{127}I(γ,xn)(γ,xn) (xx = 1,3,4,6-8), and the product yields and the corresponding flux-weighted average cross sections are reported. Our results demonstrate production of medical isotopes, with average yields of 124^{124}I and 123^{123}I at approximately 9.83±0.45×1059.83\pm0.45\times10^{5}/shot and 2.81±0.11×1052.81\pm0.11\times10^{5}/shot, respectively. This method, utilizing high-power lasers to generate bremsstrahlung radiation, shows significant potential for medical applications and opens new avenues for studying photonuclear processes in astrophysical contexts.

INTRODUCTION

Due to the development of chirped pulse amplification (CPA) and optical parametric CPA (OPCPA) technology [1, 2, 3], ultra-intense ultra-fast lasers can reach a focal intensity of 102210^{22} W/cm2^{2} [3, 4], and their interaction with the plasma produces an accelerating field with a large acceleration gradient (hundreds of GV m−1^{-1}) and a small spatial scale (a length scale of centimeters) [5], which in turn drive the acceleration of electrons and produce electron beams with a high current intensity (hundreds of kiloamperes) [6, 7]. New options for laser-accelerated electrons [8] and various application for these high-current electron sources [9, 10, 11] are being actively explored. For example, by adjusting the density of a clustered argon gas target, Shun Li et al. used a femtosecond laser interacting with a near-critical-density plasma to obtain an electron beam of 15 nC (Ee>1.2E_{\mathrm{e}} > 1.2 MeV) and produced bremsstrahlung with the photon-flux of 7×10237 \times10^{23} s−1^{-1} by bombardment of a copper target [12].

Certainly, the superposition of bremsstrahlung spectra, each with distinct endpoint energies, closely resembles the black-body Planck spectrum at a specific temperature [13]. This resemblance is particularly relevant in the context of investigating explosive nucleosynthesis phenomena in novae and supernovae [14, 15], including the γ\gamma-process and the ν\nu-process. Therefore, the ultra-intense laser-driven bremsstrahlung radiation serves as an ideal γ\gamma-ray source for replicating explosive nucleosynthesis processes in controlled laboratory environments. Furthermore, due to the ultrafast and high fluence nature of laser-driven bremsstrahlung, many researchers are applying it to diverse fields, including the study of photonuclear reaction cross sections [16], excitation of nuclear isomers [7, 17], transmutation of nuclear waste [18, 19], ultrashort pulsed photo-neutron sources [20, 21], isotope production [22, 23, 24], and many other fields of application with ultra-high efficiencies.

Isotopes of iodine play a very important role in nuclear astrophysics [25, 26], environmental protection [27], medical diagnostics [28, 29, 30, 31, 32] and cancer therapy [33]. Although 131I{}^{131}\mathrm{I} (iodine-131) pioneered clinical applications in thyroid disorder diagnosis and cancer theranostics [34], its utility is constrained by elevated radiation doses and suboptimal imaging characteristics due to predominant beta emission. The proton-rich isotopes 120–125I^{120\text{–}125}\mathrm{I} are predominantly utilized in diagnostic imaging techniques, such as single photon emission computed tomography (SPECT) and positron emission tomography (PET) [28, 31, 32], within the realm of nuclear medicine diagnostics [29, 30]. Specifically, 123I^{123}\mathrm{I} is regarded as the most appropriate isotope of iodine for the diagnostic evaluation of thyroid disorders [35, 36], owing to its favorable half-life, low dose rate, and superior imaging resolution.

The proton-rich isotopes do not necessitate a reactor-based production method. After the advent of accelerators, researchers conducted many theoretical and experimental studies to produce 122–126I^{122\text{–}126}\mathrm{I} through charged particle-induced nuclear reactions [37, 38, 39, 40, 41, 42], as well as applying the bremsstrahlung photons produced by the electron beam to produce 123I^{123}\mathrm{I} for a wide range of applications in nuclear medicine [43]. For the quantitative prediction of proton-rich iodine isotopes for nuclear medicine applications production using bremsstrahlung photon beams, understanding the flux-weighted average photoneutron reaction cross-section of 127I^{127}\mathrm{I} is of critical importance. Therefore, Naik et al. investigated the flux-weighted average cross section of 127I(γ,xn;x=1−6)^{127}\mathrm{I}(\gamma, xn; x = 1 - 6) using bremsstrahlung radiation generated by electron linac accelerator with 50 MeV and 70 MeV endpoint energies [44]. For iodine isotopes produced via photonuclear reactions, those located farther from the stability line require a greater photon flux above the threshold energy for experimental detection due to their greater total neutron separation energies. This explains why the average cross sections measurement of the 127I(γ,xn;x=6−9)^{127}\mathrm{I}(\gamma, xn; x = 6 - 9) reaction with the highest multiplicity of photoneutrons was achieved in the bremsstrahlung with an endpoint energy of 900 MeV experiment conducted by Jonsson and Lindgren (1969) at the 1.2 GeV electron synchrotron [45]. Both large-scale and commercial electron accelerators exhibit accelerating gradients constrained to approximately 100 MV/m [46] due to material limitations in radio-frequency accelerating cavities. This inherent limitation results in bremsstrahlung sources with insufficient photon flux to achieve statistically significant measurements within practical experimental durations[47], while also presenting suboptimal irradiation efficiency for industrial applications. The utilization of high-flux above-threshold bremsstrahlung generated by ultra-intense and ultra-short laser pulses represents a novel experimental methodology for investigating photonuclear reactions and a revolutionary efficient tool for industrial irradiation processes.

In the present work, we systematically optimized the electron beam parameters and beam-targeting scheme to produce a series of proton-rich iodine isotopes. This paper is structured as follows: Section II details the experimental methodology and the simulation, including (A) laser and target parameters of experiment, (B) energy and absolute detection efficiency calibration of a high-purity germanium (HPGe) γ\gamma-spectrometry and (C) Fluent and PIC-simulation setup. Section III presents (A) optimized electron parameters and their resulting bremsstrahlung versus the energy window, (B) analysis of γ\gamma spectrum, calculation of nuclide yields and identification of nuclear reaction channels, and (C) is the yield of medical iodine isotopes (e.g., 124I^{124}\mathrm{I} and 123I^{123}\mathrm{I}). Section IV summarizes the experiments and looks at some applications of laser-driven bremsstrahlung sources.

Experiment and Simulation

Experimental setup

The experiment was conducted on the 10 PW laser beamline at the Shanghai Superintense Ultrafast Laser Facility (SULF), using a single-shot operational mode with a repetition interval of approximately 15 minutes between shots. Prior to the compressor stage, the laser energy was approximately 120 J, which was reduced to about 55 J upon reaching the target, attributed to an energy transmission efficiency of approximately 46% from the compressor to the target [48]. The focal spot achieved a full width at half maximum (FWHM) of 2.1 μ\mum. The fractional laser energy within the focus spot was approximately 16% at FWHM, resulting in a peak intensity of 5.8×10215.8 \times10^{21} W/cm2^2 and a corresponding normalized amplitude of a0≈52a_0 \approx52. Furthermore, the central wavelength of the laser was 800 nm, with a pulse duration of approximately 30 fs (FWHM). Figure 1(a) presents a schematic of the experimental setup. The laser pulses were focused by an f/2 off-axis parabolic (OAP) mirror and a plasma mirror (PM) onto a deuterium (D2\mathrm{D}_2) gas ejected from a nozzle with adjustable back pressure, which featured a Gaussian density distribution. Figure 1(b) was argon (Ar) density profile measured at 20 bar back pressure. The preliminary energy spectrum, charge, and divergence angle of the electrons were characterized using a stack positioned approximately 7.5 cm from the nozzle’s center along the laser’s optical axis. The stack measured 50 mm × 50 mm, and iron sheets of varying thicknesses were inserted into different image plates (IPs) to attenuate the electron energy. The electronic parameters were ascertained using the electron stacks capable of the cutoff energy of 150 MeV and 200 MeV. Raw signals of the laser-accelerated electron beam are presented in Figure 1(e). Subsequently, a lead disk measured 51 mm × 51 mm with a thickness of 3.92 mm (as measured by a micrometer) was positioned approximately 4.8 cm from the nozzle’s center along the laser’s optical axis, serving as a converter for the bremsstrahlung radiation.

Experimental setup schematic, gas density profiles, electron density distribution, and raw electron-beam signals

Figure 1. (a) Simple schematic of the layout of the experimental setup. (b) Ar density profile at 20 bar back pressure. (c) Comparison of simulated density profiles for Argon (Ar) and Deuterium (D2\mathrm{D}_2) with the measured Ar profile at the same backing pressure, illustrating the gas density used in the experiment. (d) Electron density distribution during particle-in-cell (PIC) simulation. (e) Raw signals of the laser-accelerated electron beam recorded in the IPs.

To achieve a sufficiently intense bremsstrahlung radiation, a 2-inch cylindrical sodium iodide (NaI(Tl)) crystal with a diameter of 5.08 cm and a thickness of 5.08 cm, positioned immediately adjacent to the bremsstrahlung converter, was irradiated under the optimal electronic parameters. To maintain the stability of the laser parameters, the interval between each laser pulse was set to approximately 15 minutes. Owing to the constraints imposed by the plasma mirrors, it was necessary to devacuum the target chamber and replace the plasma mirrors after every 5 shots. Upon re-establishing vacuum conditions within the target chamber, it was essential to reconfirm the laser focal spot and other critical parameters. Consequently, the interval between the last five laser pulses and the initial five pulses spanned approximately 3 hours, with each pulse being separated by about 15 minutes.

HPGe detector calibrations

Following a 10-minute deflation of the target chamber, the irradiated NaI(Tl) crystals were extracted. Subsequently, the γ\gamma-rays emitted from the radioactive decay of the photodisintegration products of the 127I(γ,xn;x=1,3,4,6–8){}^{127}\mathrm{I}(\gamma, xn; x = 1, 3, 4, 6\text{--}8) reaction, including 126I{}^{126}\mathrm{I}, were detected using a high-purity germanium (HPGe) detector. This HPGe detector is a member of the N-type coaxial GMX series (model number GMX50P4-83) from ORTEC, featuring a carbon fiber endcap above the Beryllium window designed to minimize background noise [49]. This specific model boasts a relative detection efficiency of 50% and an endcap diameter of 83 mm. The relative photopeak efficiency is defined as the efficiency at the 1.33 MeV photopeak of a Co-60 point source positioned 25 cm from the surface of a standard Φ\Phi3 inch ×\times 3 inch cylindrical NaI(Tl) detector [50]. The output signal from the HPGe detector is captured by the fully integrated γ\gamma spectrometer DSPEC 50 [51] and the computer software GammaVision [52], both developed by ORTEC. In list mode, both the signal size and timestamps are logged, enabling the acquisition of the γ\gamma-ray energy spectrum of the sample at any given time during measurement. This capability allows for the subsequent calculation of the half-life corresponding to a single full energy peak.

The energy linearity of the entire detection system, calibrated with Co-60 and Na-22 standard sources, along with the absolute detection efficiency of the full energy peaks combined with Geant4 [53, 54, 55] simulations, is illustrated in Figure 2, where the volume source is defined based on Geant4 [54, 55] simulations of experimental beam-target conditions to obtain the distribution of 126I{}^{126}\mathrm{I} in NaI(Tl) crystals. The absolute efficiency curves of the HPGe detector for point and volumetric sources were obtained by fitting the absolute detection efficiencies obtained at different energy points of the Geant4 simulation by a polynomial function:

HPGe detector energy calibration and absolute detection efficiency calibration for point and volumetric sources

Figure 2. HPGe detector energy calibration and absolute detection efficiency calibration for point and volumetric sources.

ϵ(Eγ)=∑i=08pi⋅log⁡10(Eγ)(1)\epsilon(E_\gamma) = \sum_{i=0}^{8} p_i \cdot\log_{10}(E_\gamma) \tag*{(1)}

where pip_i were free parameters to be determined. Additionally, the energy resolution is characterized by a full width at half maximum (FWHM) of 2.02 keV at the 60Co{}^{60}\mathrm{Co} peak of 1332.5 keV. Details of the HPGe detector and

Geant4 [54, 55] simulations are provided in the Supplementary Material[56].

Simulated setup

Given that the initial gas density measurements were obtained using argon, we conducted computational fluid dynamics (CFD) simulations using the commercial software ANSYS FLUENT [57], which employs numerical discretization techniques to solve the governing Navier-Stokes equations on a discretized computational mesh [58, 59], to establish the corrected gas density for deuterium in our experimental system. The density distributions of both argon and deuterium under 20 bar inlet pressure conditions were numerically resolved using a density-based solver implemented on a 2D axisymmetric computational mesh with 5 μm\mu\mathrm{m} characteristic cell size.

A particle-in-cell (PIC) simulations were performed to find suitable electron peak density for experiment using the Smilei [60] code in cylindrical geometry with azimuthal mode decomposition [61], incorporating a laser envelope model [62]. The computational grids are set to Lx=2304 μm×Lr=179.2 μmL_x=2304\ \mu\mathrm{m} \times L_r=179.2\ \mu\mathrm{m}, with corresponding spatial resolutions of 11520 cells along the xx direction and 448 cells along the rr direction. Per-cell initialization employed 16 macro-particles (8 electron + 8 D+^+ ions) possessing matching Gaussian density distributions centered at x0=870 μmx_0 = 870\ \mu\mathrm{m} with FWHM = 946 μm\mu\mathrm{m}. A yy-polarized Gaussian beam (λL=800 nm\lambda_L = 800\ \mathrm{nm}) propagates in +xx direction, focused at xf=x0−100 μmx_f = x_0 - 100\ \mu\mathrm{m}. The laser pulse features a Gaussian transverse profile with waist ω0=1.8 μm\omega_0 = 1.8\ \mu\mathrm{m} at the focal spot and a longitudinal temporal envelope of 30 fs FWHM, corresponding to a normalized vector potential of a0=52a_0 = 52. A plane screen diagnostic was positioned at xscreen=Lx−590 μmx_{\mathrm{screen}}= L_x - 590\ \mu\mathrm{m} to detect electrons traversing the plane along the positive xx-direction. Figure 1(d) is the electron density distribution during PIC simulation.

RESULT AND DISCUSSION

Laser driven bremsstrahlung

The molecular density of deuterium at the target position (500 μm\mu\mathrm{m} downstream from the nozzle) demonstrates a reduction compared to argon under 20 bar back pressure conditions, attributable to the combined effects of its lower molecular weight (4.032 g/mol for D2_2, 39.948 g/mol for Ar) and distinct transport properties including heat capacity, thermal conductivity, and viscosity[63]. The argon molecular density profile simulated by ANSYS Fluent under 20 bar back pressure demonstrates strong congruence with experimental measurements and the difference in density between argon and deuterium gases under the same back pressure condition at the targeting position, as shown in Figure 1(c).

Prior to the electron irradiation of the bremsstrahlung converter, the optimal electron parameters, specifically the charge and energy, were determined by adjusting the gas pressure of the deuterium gas ejected from the nozzle. Our PIC simulations demonstrate that the optimal electron peak density matching the laser parameters lies within 0.012nc0.012n_c to 0.023nc0.023n_c in where the nc=ϵ0meω2e2n_c = \frac{\epsilon_0 m_e \omega^2}{e^2}, namely, ∼1.7×1021 cm−3\sim1.7 \times10^{21}\ \mathrm{cm}^{-3} for 800 nm laser wavelength. Since the simulations do not exactly match the experimental conditions, experimental scanning of the electron density parameters is required to determine the optimal targeting conditions. Experimental verification through analysis of electron spectrometer measurements reveals an optimal electron peak density of 0.018nc0.018n_c for laser-plasma electron acceleration, which falls within the simulated range. Owing to the relativistic self-focusing power Pf=P0(nc/ne)P_f=P_0(n_c/n_e) (where the natural power P0=8.7P_0=8.7 GW), the Gaussian laser beam undergoes strong self-focusing within the plasma under our experimental conditions. As illustrated in Figure 1(d), PIC simulations reveal that the laser ponderomotively expels plasma electrons from the optical axis, forming a plasma channel. The interaction between the laser field and the nonlinear focusing forces within this channel leads to electron acceleration [64]. Since the laser power significantly exceeds the relativistic self-focusing threshold, the laser beam splits into multiple sub-beams that focus independently, resulting in a multi-filament structure [65]. The experimental results are presented in Figure 3. The experimental uncertainties originate from four primary sources: statistical fluctuations in the original photostimulated luminescence (PSL) measurements, inaccuracies in the saturation correction factor, errors associated with the temporal decay factor (7% [66]), and uncertainties in the electron number conversion process from PSL values (20% [66]). Quantitative analysis of electron spectrometer data (Figure 1(e)) indicates that laser-plasma acceleration at 0.018nc0.018n_c achieves: (1) a total electron charge of 47.4 nC (Ee>10.4E_e>10.4 MeV), (2) an energy conversion efficiency of 13.5%, and (3) transverse divergence angles of 17.95∘17.95^\circ (x-direction) and 18.33∘18.33^\circ (y-direction), representing optimal beam quality within the tested parameter space. The experimentally measured electron energy spectra at other back pressures are provided in the Supplementary Material [56].

Electron charge and energy conversion efficiency versus electron peak density

Figure 3. Blue symbols and lines denote the total charge (in nC) measured experimentally across varying peak electron densities. Similarly, yellow symbols and lines indicate the energy conversion efficiency from laser energy to total electron energy (Ee≥10 MeVE_e \ge10\ \mathrm{MeV}) measured experimentally. Vertical error bars for experimental data reflect measurement uncertainty in the electron stack diagnostics.

The Gaussian laser beam, focused by a low f-number OAP mirror, achieves a high peak power density. However, its Rayleigh length xR=πω02/λL=12.7x_R=\pi\omega_0^2/\lambda_L=12.7 μm (for a beam waist ω0=1.8\omega_0=1.8 μm) indicates that plasma waves is not the dominant acceleration mechanism. As shown in Figure 1(c), the electron density exhibits a Gaussian profile. During laser propagation in low-density plasma, the laser pulse excites plasma waves, but electron injection is suppressed because the laser spot size ω(x)=ω01+(x−x0zR)2\omega(x)=\omega_0\sqrt{1+\left(\frac{x-x_0}{z_R}\right)^2} significantly exceeds the plasma wavelength λp(μm)≈3.3×1010/ne(cm−3)\lambda_p(\mu\mathrm{m})\approx3.3\times10^{10}/\sqrt{n_e(\mathrm{cm}^{-3})}. At higher electron densities, intense laser self-focusing occurs prior to the geometric focus. The ponderomotive force of laser field that expels background electrons transversely, forming a plasma channel. Within this channel, the laser’s transverse electric field accelerates electron and the laser’s magnetic field collimates it along the propagation axis. Consequently, the electron energy spectra exhibit a broad energy spread characteristic of laser-plasma interactions, as shown in both the PIC-simulated and experimental results in Figure 4(b) at the electron peak density of 0.018nc0.018n_c. The experimental data are fitted with a bi-exponential function corresponding to a two-temperature distribution (Te1=7.56T_{e1}=7.56 MeV; Te2=40.21T_{e2}=40.21 MeV). The discrepancies between the experimental and simulated energy spectra primarily arise from the following factors: (1) the experimental setup lacks perfect cylindrical symmetry; (2) intense forward-directed

Bremsstrahlung spectrum and electron energy spectra

Figure 4. (a)Bremsstrahlung spectrum (Geant4 [54, 55]), 127{}^{127}I(γ,xn)(\gamma,xn) cross sections (TALYS 2.0 [67]), and energy window for 127{}^{127}I(γ,n)(\gamma,n)126{}^{126}I. The curve labeled ’Energy window’ represents the product of the photon flux and the reaction cross section, highlighting the most effective energy range for the photonuclear reaction, analogous to the Gamow window in charged-particle-induced reactions. (b) Electron energy spectra obtained from electron stack measurements (blue data points) were fitted using a dual-temperature model (Te1T_{e1} and Te2T_{e2}). Horizontal error bars indicate energy bin intervals, while vertical error bars represent measurement uncertainties in the electron stack. The green curve corresponds to the simulated energy spectrum derived from Particle-in-Cell (PIC) simulations.

X-rays and γ-rays generated during direct laser acceleration of electrons Compton-scatter off the iron foil stack, producing secondary electrons; and (3) strong laser self-focusing in the plasma introduces differences not fully captured by the envelope approximation used in the PIC simulations. Utilizing the aforementioned electron energy spectrum and the dimensions of the lead target, the bremsstrahlung radiation spectrum was simulated using Geant4 [54, 55], with the results depicted in Figure 4(a).

Reference [68] investigated the nucleosynthesis of proton-rich heavy nuclei in stellar photon baths under astrophysical γ-process temperatures, where the photon bath was modeled by superimposing bremsstrahlung spectra with six endpoint energies. As illustrated in Figure 4(a), the ultra-intense femtosecond bremsstrahlung radiation generated in our laser-driven experiment originates from the superposition of bremsstrahlung produced by multi-energy electrons interacting with the lead target. This radiation spectrum at the low temperature end exhibits remarkable similarities to the X-ray/γ-ray spectral profiles observed in astrophysical photodisintegration reactions. It should also be noted that we have computed the (γ,xn;x=1−8)(\gamma,xn;x=1-8) nuclear reaction cross-section for a 127{}^{127}I target utilizing the default parameters of the Talys 2.0 [67] code. By integrating Bremsstrahlung spectrum analysis with nuclear reaction cross-section calculations within a unified theoretical framework, our computational methodology reveals the emergence of a energy window for photon-induced nuclear reactions that is strikingly analogous to the classical Gamow peak observed in charged-particle-induced processes under equivalent astrophysical conditions. Such experimental realization establishes a valuable platform for investigating the formation mechanisms of proton-rich nuclei in nuclear astrophysical environments, particularly regarding the nucleosynthesis processes of p-nuclei. In our experimental setup, proton-rich iodine isotopes are synthesized through bremsstrahlung irradiation, demonstrating a novel approach to probe nucleosynthesis pathways in proton-rich nuclei.

Laser driven nuclear reaction

The decay data for radionuclides resulting from the NaI(Tl) activation reaction are detailed in Table I. The identification of the nuclide type produced in an activated target can be accomplished through the analysis of the positions of the full-energy peaks within the γ\gamma-ray energy spectrum. Additionally, the consistency of the ratio of the net areas of these peaks, adjusted for detection efficiency, with the branching ratios of each γ\gamma decay provides essential information.

NucleusThreshold/MeVT1/2T_{1/2}γ\gamma energy/keVγ\gamma branchDetector efficiency ϵv\epsilon_vNet counts NnetN_{\mathrm{net}}Yields Yˉ\bar{Y}
128I{}^{128}\mathrm{I}24.99 min442.901a^{a}12.61%0.01632125±762125 \pm766.28±0.23×1056.28 \pm0.23 \times10^{5}
126I{}^{126}\mathrm{I}9.1412.93 d666.33132.9%
753.8194.15%
1420.20.30386%
388.633a^{a}35.6%0.017026756±18026756 \pm1801.03±0.0069×1081.03 \pm0.0069 \times10^{8}
491.2432.88%
879.8760.743%
124I{}^{124}\mathrm{I}25.844.176 d602.73a^{a}62.9%0.01391127±521127 \pm529.83±0.45×1059.83 \pm0.45 \times10^{5}
1690.9611.15%
722.7810.36%
1509.363.25%
1376.091.79%
1325.521.578%
123I{}^{123}\mathrm{I}33.3313.223 h159.00a^{a}83.60%0.01192364±892364 \pm892.81±0.11×1052.81 \pm0.11 \times10^{5}
121I{}^{121}\mathrm{I}51.172.12 h212.20a^{a}84.3%0.0154617±55617 \pm552.00±0.18×1042.00 \pm0.18 \times10^{4}
120I{}^{120}\mathrm{I}61.7581.6 min560.40a^{a}69.6%0.0146123±30123 \pm304.87±1.19×1034.87 \pm1.19 \times10^{3}
119I{}^{119}\mathrm{I}69.8019.1 min257.52a^{a}86.3%0.016963±4163 \pm413.42±2.23×1033.42 \pm2.23 \times10^{3}
24Na{}^{24}\mathrm{Na}14.956 h1368.625a^{a}99.994%0.0087136±1536 \pm155.44±2.27×1035.44 \pm2.27 \times10^{3}
2754.00899.867%

Table I. Correlated decay data for radionuclides from sodium iodide activation reactions. The energies and branch ratios were given by NuDat 3.0 [69].

By analyzing the γ\gamma-ray energy spectrum of the activated target, the characteristic peaks of 119−121,123,124,126,128I^{119-121,123,124,126,128}\mathrm{I} and 24Na^{24}\mathrm{Na} were clearly discernible above the background noise and Compton continuum, as depicted in Figure 5. As illustrated in Figure 5, the characteristic γ\gamma-rays of the nuclides listed in Table I manifest as full-energy peaks in the γ\gamma-ray energy spectra acquired from the measurements of the activated sodium iodide target using a high-purity germanium detector. Given that the measurement of the sodium iodide target commenced 10 minutes post-targeting and the data acquisition duration for the energy spectrum presented in Figure 5 was 15.45 hours, the characteristic full-energy peaks for 122I(T1/2=3.63 min)^{122}\mathrm{I}(T_{1/2}=3.63\ \mathrm{min}) and 125I(T1/2=59.41 d)^{125}\mathrm{I}(T_{1/2}=59.41\ \mathrm{d}) are absent. In contrast to 126I^{126}\mathrm{I} and 124I^{124}\mathrm{I}, which have lower production thresholds, other nuclides further from the line of stability exhibit only the signature γ\gamma-ray with the largest branching ratio, showing a weak full-energy peak in the measured spectra due to their low yields and the significantly smaller branching ratio of the secondary signature γ\gamma-ray. As the radionuclide decays, the net count rate of the full-energy peak decreases exponentially at a rate defined by its decay constant, λ\lambda. The half-life of the peak, which corresponds to the half-life of the nuclide, can be determined by fitting the decay of the net count rate. The fitting function employed adheres to the standard formula for radioactive decay:

Typical $\gamma$ energy spectrum of NaI(Tl) target activation signals measured by HPGe

Figure 5. Typical γ\gamma energy spectrum of NaI(Tl) target activation signals measured by HPGe for 15.45 h.

dNnetdt=λN0⋅exp⁡(−λt)(2)\frac{dN_{net}}{dt}=\lambda N_0\cdot\exp(-\lambda t) \tag*{(2)}

Consequently, by computing the net area of the distinctive all-energy peaks in the γ\gamma energy spectrum at each timestamp and determining the net count rate, the uncertainty in which is obtained from one standard deviation of the increment in net counts, we can plot the variation in the net count rate of the characteristic peaks against time. This plot is then fitted to Equation (2), as illustrated in Figure 6. The determined half-lives from the fittings are generally consistent with those provided by the NuDat 3.0 [69] database. The greater deviations observed for the longer-lived nuclides, 126I^{126}\mathrm{I} and 124I^{124}\mathrm{I}, can be attributed to the shorter measurement durations employed. In instances where the signal is strong and the measurement duration exceeds the half-life of the nuclide, the discrepancy between our calculated half-life values and those reported by previous authors is less than 10%. Conversely, when our measurements are conducted over a shorter period than the nuclides’ lifetimes. In summary, by correlating the peak positions and half-lives, we can ascertain the nuclides generated by the experiment, with the notable exception of 119I^{119}\mathrm{I}. The yield of 119I^{119}\mathrm{I} was insufficient to perform a reliable half-life analysis due to poor statistics in the 257.81 keV full-energy peak. However, this energy peak is definitively assigned to 119I^{119}\mathrm{I} based on the known reaction channel on the NaI target and corroboration with the NuDat 3.0 database [69].

Typical decay curves for the isotopes $^{126}\mathrm{I}$, $^{124}\mathrm{I}$, $^{123}\mathrm{I}$, $^{121}\mathrm{I}$, $^{120}\mathrm{I}$

Figure 6. Typical decay curves for the isotopes 126I^{126}\mathrm{I}, 124I^{124}\mathrm{I}, 123I^{123}\mathrm{I}, 121I^{121}\mathrm{I}, 120I^{120}\mathrm{I} obtained from an irradiation of NaI(Tl) with bremsstrahlung.(The legend for the data points indicates the full energy peaks of nuclide used for the calculations and the half-life values for that nuclide from NuDat 3.0 [69])

Subsequently, the final yield of the nuclide at the conclusion of irradiation can be deduced from the net area under the photo-peaks. This calculation is articulated as follows:

Yˉ=Nnet[∑i=1nexp⁡(−λ⋅Δti)]⋅Iγ⋅ϵν⋅[1−exp⁡(−λt)]=NνD∫EthrEmaxσ(E)ϕγ(E)dE(3)\bar{Y}=\frac{N_{net}}{\left[\sum_{i=1}^{n}\exp(-\lambda\cdot\Delta t_i)\right]\cdot I_{\gamma}\cdot\epsilon_{\nu}\cdot\left[1-\exp(-\lambda t)\right]} =N_{\nu}D\int_{E_{thr}}^{E_{max}}\sigma(E)\phi_{\gamma}(E)dE \tag*{(3)}

In the first term of equation (3), Yˉ\bar{Y} denotes the average reaction yield per laser pulse, NnetN_{net} represents the net area under the photo-peaks, IγI_{\gamma} is the decay intensity of the characteristic γ\gamma-rays, tt is the actual measurement time, Δti\Delta t_i is the time difference between the ii-th laser pulse and the start of the sample measurement, λ\lambda is the decay constant, and ϵν\epsilon_{\nu} is the peak detection efficiency of the HPGe detector for volumetric sources. Based on equation (3) and the parameters in Table I, we can calculate the average yield of nuclides at the end of per targeting. The error in the nuclear reaction yields comes from the error in calculating the net area of the Gaussian fit to the full-energy peak. For continuous γ\gamma-spectra, the nuclear reaction yield can be theoretically calculated by the second term of equation (3), where NνN_{\nu} is the number density of target nuclei, DD is the target thickness, EthrE_{thr} is the reaction threshold energy, EmaxE_{max} is the maximum bremsstrahlung photon energy, σ(E)\sigma(E) is the energy-dependent reaction cross section, ϕ(E)\phi(E) is the bremsstrahlung photon flux. In studies of bremsstrahlung-induced photonuclear reactions, the flux-weighted average cross section ⟨σ⟩\langle\sigma\rangle is commonly employed to compare experimental measurements

with theoretical calculations, defined as:

⟨σ⟩=∫EthrEmaxσ(E)ϕγ(E) dE∫EthrEmaxϕγ(E) dE(4)\langle\sigma\rangle= \frac{\int_{E_{\mathrm{thr}}}^{E_{\mathrm{max}}} \sigma(E)\phi_{\gamma}(E)\,dE}{\int_{E_{\mathrm{thr}}}^{E_{\mathrm{max}}} \phi_{\gamma}(E)\,dE} \tag*{(4)}

The flux-weighted average cross section was experimentally derived from nuclear reaction product yields using the Geant4[54, 55]-simulated bremsstrahlung spectrum, while theoretically computed via TALYS 2.0 code[67], with both results summarized in Table II.

Nuclear reactionγ\gamma endpoint energy/MeVFlux-weighted average cross section (⟨σ⟩\langle\sigma\rangle)/mb
ExperimentTALYS 2.0
127I(γ,n)126I^{127}\mathrm{I}(\gamma,n)^{126}\mathrm{I}150.0102.76±\pm0.6968.66
127I(γ,2n)125I^{127}\mathrm{I}(\gamma,2n)^{125}\mathrm{I}150.0Not observed31.46
127I(γ,3n)124I^{127}\mathrm{I}(\gamma,3n)^{124}\mathrm{I}150.06.54±\pm0.306.27
127I(γ,4n)123I^{127}\mathrm{I}(\gamma,4n)^{123}\mathrm{I}150.03.12±\pm0.123.50
127I(γ,5n)122I^{127}\mathrm{I}(\gamma,5n)^{122}\mathrm{I}150.0Not observed1.47
127I(γ,6n)121I^{127}\mathrm{I}(\gamma,6n)^{121}\mathrm{I}150.00.57±\pm0.0510.88
127I(γ,7n)120I^{127}\mathrm{I}(\gamma,7n)^{120}\mathrm{I}150.00.23±\pm0.0570.38
127I(γ,8n)119I^{127}\mathrm{I}(\gamma,8n)^{119}\mathrm{I}150.00.24±\pm0.150.22

Table II. The flux-weight average cross sections of 127I(γ,xn)119–126I^{127}\mathrm{I}(\gamma,xn)^{119\text{--}126}\mathrm{I} reactions and the theoretical values based on the TALYS 2.0 code[67].

As depicted in Figure 4(a), The cross-section in photonuclear processes exhibits an inverse correlation with neutron evaporation multiplicity. Figure 7 illustrates the experimentally measured flux-weighted average cross section as functions of number of emitted neutrons, Compared with theoretical values based on the TALYS 2.0 code[67], the work of Jonsson et al. [70] and the work of Naik et al. [44]. The reaction channels leading to 125I^{125}\mathrm{I} (x=2x=2) and 122I^{122}\mathrm{I} (x=5x=5) were not experimentally observed, consistent with their respective long and short half-lives under our experimental conditions. However, their theoretical flux-weighted average cross sections, calculated using TALYS 2.0, are included in Table II and Figure 7 for a comprehensive comparison. The experimentally measured flux-weighted average cross section decreases approximately exponentially with the number of neutrons emitted, particularly when the number of emitted neutrons exceeds two. The predicted cross section for the (γ,2n)(\gamma,2n) reaction is comparable to that of the (γ,3n)(\gamma,3n) channel, while the (γ,5n)(\gamma,5n) channel follows the established exponential decay trend. The exponential coefficients are 0.81 per neutron. As discussed by Jonsson and Forkman in Ref.[70], when the number of neutrons exceeds two, the flux-weighted average cross section decreases nearly exponentially with respect to the number of emitted neutrons, exhibiting exponential coefficients of 0.56 per neutron at photon energies of 800 MeV, respectively. The steeper exponential decline observed in our work (0.81 per neutron) compared to that reported by Jonsson et al.[70] (0.56 per neutron) may be attributed to the different endpoint energies of the bremsstrahlung sources (150 MeV vs. 800 MeV). The higher photon flux from bremsstrahlung driven by higher-energy electron beams, within the relevant nuclear energy window, promotes population of multiple neutron emission channels. This can lead to a flatter decreasing trend of the photoneutron cross section as a function of the emitted neutron number. This correlation arises because, with increasing energy, reaction channels such as emitted charged particles compete with neutron emission. Additionally, the yield of isotope 126I^{126}\mathrm{I} might include contributions from the photonuclear reactions induced by Compton-scattered photons in thick targets and the reaction channel 127I(n,2n)126I^{127}\mathrm{I}(n,2n)^{126}\mathrm{I}, which has a threshold of 9.217 MeV. Halpern et al. observed in the Cu-As region that it is more facile to evaporate neutrons from stable nuclei with a higher atomic number A [71]. For heavy nuclei like 127I^{127}\mathrm{I}, Jonsson et al.’s previous (γ,xn)(\gamma,xn) experiment [45] utilized a monoenergetic electron beam converted to bremsstrahlung to irradiate iodine samples from reaction thresholds up to 900 MeV, measuring 118I^{118}\mathrm{I}. In contrast, our experiment, employing a significantly lower energy but higher charge, measured a substantially lower nuclear reaction cross section for 119I^{119}\mathrm{I}. As demonstrated in Figure 4(a), when xx is greater than or equal to 7, the cross-section reduces to below 1 mb. This suggests that laser-accelerated electrons produce a high-current electron beam over a short timescale, which is then converted into a high-flux bremsstrahlung radiation suitable for studying cross-section (γ,xn)(\gamma,xn) nuclear reactions.

The experimentally measured flux-weighted average cross section as functions of number of emitted neutrons

Figure 7. The experimentally measured flux-weighted average cross section as functions of number of emitted neutrons, Compared with theoretical values based on the TALYS 2.0 code[67], the work of Jonsson et al. [70] and the work of Naik et al. [44]. The dashed lines represent exponential fit to the data.

As shown in Figure 5 and Table I, the appearance of the 442.90 keV γ\gamma line in the energy spectrum given by the reaction 127I(n,γ)128I^{127}\mathrm{I}(n,\gamma)^{128}\mathrm{I} and the calculation of its half-life clarifies the production of 128I^{128}\mathrm{I} with an average yield for a single shot of 6.28±0.23×1056.28 \pm0.23 \times10^{5}; the appearance of the 1368.63 keV γ\gamma line given by the reaction 23Na(n,γ)24Na^{23}\mathrm{Na}(n,\gamma)^{24}\mathrm{Na} in the energy spectrum and the calculation of its half-life clarified the production of 24Na^{24}\mathrm{Na} with an average yield of 5.44±2.27×1035.44 \pm2.27 \times10^{3} for a single shot. The nuclear reaction yield of 128I^{128}\mathrm{I} is more than that of 24Na^{24}\mathrm{Na} because the neutron capture cross section of 127I^{127}\mathrm{I} is larger than that of 23Na^{23}\mathrm{Na}. This indicates that a significant flux of photoneutrons was generated, which in turn induced secondary neutron capture reactions on 127I^{127}\mathrm{I} and 23Na^{23}\mathrm{Na} within the thick target. This further demonstrates that the neutrons generated through these photonuclear reactions can serve as an ultrashort-pulse neutron source for investigating fundamental phenomena in neutron physics.

Yields of medical iodine isotopes

Erwann et al. conducted a comparison of the image quality between 131I^{131}\mathrm{I} and 123I^{123}\mathrm{I} for single-photon emission computed tomography (SPECT) imaging and 124I^{124}\mathrm{I} for positron emission tomography (PET) imaging [28]. Their findings indicated that 124I^{124}\mathrm{I} exhibited the superior imaging performance, which can be attributed to the electron collimation and a short coincidence time win-

dow. The isotope of 124I^{124}\mathrm{I} and 123I^{123}\mathrm{I} is primarily produced utilizing charged particles beams. In our experimental setup, laser-accelerated electrons with energies ranging from 25.8 to 150.0 MeV produced a total charge of 16.18 nC/shot. This electron beam subsequently generated bremsstrahlung radiation, which induced a photonuclear reaction yielding 9.83±0.45×1059.83 \pm0.45 \times10^{5}/shot of 124I^{124}\mathrm{I}. In contrast to 131I^{131}\mathrm{I}, which is previously extensively employed as a thyroid scanning agent, 123I^{123}\mathrm{I} possesses a half-life of 13.223 hours, rendering it highly suitable for 24-hour iodine uptake tests [35]. Our study achieved a 123I^{123}\mathrm{I} yield of 2.81±0.11×1052.81 \pm0.11 \times10^{5}/shot within the energy range of 33.3-150.0 MeV.

To compare the effects of electron energy spectra at different effective temperatures on the production of 124I^{124}\mathrm{I} and 123I^{123}\mathrm{I}, we performed Geant4 [54, 55] simulations under experimental irradiation conditions. As shown in Figure 8, the maximum yields of 124I^{124}\mathrm{I} and 123I^{123}\mathrm{I} were achieved at a gas jet backing pressure of 18 bar (ne=0.018ncn_{\mathrm{e}}=0.018n_{\mathrm{c}}), corresponding to effective temperatures of Te1=7.6T_{\mathrm{e1}}=7.6 MeV and Te2=40.2T_{\mathrm{e2}}=40.2 MeV. The production of 124I^{124}\mathrm{I} and 123I^{123}\mathrm{I} via photonuclear reactions on 127I^{127}\mathrm{I} requires the stripping of three and four neutrons from the nucleus, respectively. The reaction cross-sections govern the production yields of these isotopes. Two primary optimization approaches exist: (1) Enhancing the γ\gamma-ray flux of laser-driven bremsstrahlung sources above the reaction threshold, and (2) employment of photonuclear reaction channels with larger cross-sections, such as 124Xe(γ,n)123Xe→123I^{124}\mathrm{Xe}(\gamma,n)^{123}\mathrm{Xe}\rightarrow{}^{123}\mathrm{I} [43].

Image not extracted

Figure 8. The 124I^{124}\mathrm{I} and 123I^{123}\mathrm{I} yields obtained from Geant4 [54, 55] simulations are plotted with different colors corresponding to distinct gas jet backing pressures, representing the yields under electron energy spectra at different effective temperatures.

Conclusion

We have conducted experiments irradiating a sodium iodide target with high-flux bremsstrahlung radiation, generated by ultra-intense, ultra-fast laser-driven electron acceleration at the SULF-10PW beamline. Following a ten-shot irradiation, our investigation successfully produced a series of proton-rich iodine isotopes and calculated the corresponding flux-weighted average cross-section, notably including 123I^{123}\mathrm{I} and 124I^{124}\mathrm{I} that are extensively utilized in nuclear medicine for diagnostic and therapeutic applications. Particularly noteworthy is the identification of the (γ,8n)(\gamma, 8n) reaction channel in the photonuclear reaction of 127I^{127}\mathrm{I}, Additionally, we measured the characteristic peaks of 128I^{128}\mathrm{I} and 24Na^{24}\mathrm{Na}, which were predominantly produced by secondary reactions triggered by photoneutrons. Furthermore, the experiments have verified that laser-driven bremsstrahlung is a promising alternative compared to traditional methods of photonuclear reaction investigation and medical iodine isotope production.

Utilizing the laser-driven bremsstrahlung source, we can delve into the nuclear reactions involving multiphoton absorption on a short time scale with a large γ\gamma flux, specifically, the photon absorption reactions at certain short-lived energy levels within the nucleus. This approach is instrumental in generating and investigating the properties of proton-rich nuclides far from the valley of stability. This bremsstrahlung-generated photon bath with thermal spectral characteristics enables systematic studies of γ\gamma-induced reaction cross-sections and rates in astrophysically relevant energy regimes. Beyond fundamental physics, ultra-intense, ultra-fast lasers are poised to become an efficient tool in applications such as the production of medical isotopes.

ACKNOWLEDGMENTS

The authors thank the staff of the 10 PW laser beamline at the Shanghai Superintense Ultrafast Laser Facility for the excellent operation of the laser facility and their support during the experiment. This work was supported by the National Key R&D Program of China (Nos.2022YFA1602200, 2022YFA1602400), the Strategic Priority Research Program of the CAS (No.XDB0890302), and the National Natural Science Foundation of China (Nos.12235003, 12388102).

References

  1. [1]S. Donna and M. Gerard, Compression of amplified chirped optical pulses, Optics Communications 56, 219 (1985).
  2. [2]G. A. Mourou, T. Tajima, and S. V. Bulanov, Optics in the relativistic regime, Rev. Mod. Phys. 78, 309 (2006).DOI
  3. [3]C. N. Danson, C. Haefner, J. Bromage, T. Butcher, J.-C. F. Chanteloup, E. A. Chowdhury, A. Galvanauskas, L. A. Gizzi, J. Hein, D. I. Hillier, and et al., Petawatt and exawatt class lasers worldwide, High Power Laser Science and Engineering 7, e54 (2019).
  4. [4]K. A. Tanaka, K. M. Spohr, D. L. Balabanski, S. Balascuta, L. Capponi, M. O. Cernaiunu, M. Cuciuc, A. Cucoanes, I. Dancus, A. Dhal, B. Diaconu, D. Doria, P. Ghenuche, D. G. Ghita, S. Kisiov, V. Nastasa, J. F. Ong, F. Rotaru, D. Sangwan, P. A. Söderström, D. Stutman, G. Suliman, O. Tesileanu, L. Tudor, N. Tsonева, C. A. Ur, D. Ursescu, and N. V. Zamfir, Current status and highlights of the eli-np research program, Matter and Radiation at Extremes 5, 024402 (2020).DOI
  5. [5]E. Esarey, C. B. Schroeder, and W. P. Leemans, Physics of laser-driven plasma-based electron accelerators, Rev. Mod. Phys. 81, 1229 (2009).DOI
  6. [6]T. Tajima and J. M. Dawson, Laser electron accelerator, Phys. Rev. Lett. 43, 267 (1979).DOI
  7. [7]J. Feng, Y. J. Li, J. H. Tan, W. Z. Wang, Y. F. Li, X. P. Zhang, Y. Meng, X. L. Ge, F. Liu, W. C. Yan, C. B. Fu, L. M. Chen, and J. Zhang, Laser plasma-accelerated ultra-intense electron beam for efficiently exciting nuclear isomers, Laser & Photonics Reviews 17, 2300514 (2023).arxiv.org/abs/2203.06454
  8. [8]J. L. Shaw, M. A. Romo-Gonzalez, N. Lemos, P. M. King, G. Bruhaug, K. G. Miller, C. Dorrer, B. Kruschwitz, L. Waxer, G. J. Williams, M. V. Ambat, M. M. McKie, M. D. Sinclair, W. B. Mori, C. Joshi, H. Chen, J. P. Palastro, F. Albert, and D. H. Froula, MicromCoulomb (0.7±0.4 μC) laser plasma accelerator on OMEGA EP, Scientific Reports 11, 7498 (2021).
  9. [9]F. Mirani, D. Calzolari, A. Formenti, and M. Passoni, Supertensise laser-driven photon activation analysis, Communications Physics 4, 185 (2021).arxiv.org/abs/2104.07513
  10. [10]Z. C. Li, H. W. Wang, W. Luo, Y. Yang, Z. W. Cao, X. X. Li, Y. Yuan, Z. Q. Zhao, and G. T. Fan, Effective extraction of photonuclear cross-section distribution using gamma activation and reaction yield ratio method, Nuclear Science and Techniques 34, 170 (2023).DOI
  11. [11]L. Fan, T. Xu, S. Li, Z. Xu, J. Xu, J. Zhu, B. Shen, and L. Ji, Collimated gamma beams with high peak flux driven by laser-accelerated electrons, High Power Laser Science and Engineering 11, e26 (2023).DOI
  12. [12]S. Li, B. F. Shen, J. C. Xu, T. J. Xu, Y. Yu, J. F. Li, X. M. Lu, C. Wang, X. L. Wang, X. Y. Liang, Y. X. Leng, R. X. Li, and Z. Z. Xu, Ultrafast multi-mev gamma-ray beam produced by laser-accelerated electrons, Physics of Plasmas 24, 093104 (2017).DOI
  13. [13]M. Arnould and S. Goriely, The p-process of stellar nucleosynthesis: astrophysics and nuclear physics status, Physics Reports 384, 1 (2003).DOI
  14. [14]T. Hayakawa, T. Nakamura, H. Kotaki, M. Kando, and T. Kajino, Explosive nucleosynthesis study using laser driven γ-ray pulses, Quantum Beam Science 1 (2017).DOI
  15. [15]A. Zilges, D. L. Balabanski, J. Isaak, and N. Pietralla, Photonuclear reactions—from basic research to applications, Progress in Particle and Nuclear Physics 122, 103903 (2022).DOI
  16. [16]D. Wu, H. Y. Lan, J. Y. Zhang, J. X. Liu, H. G. Lu, J. F. Lv, X. Z. Wu, H. Zhang, J. Cai, Q. Y. Ma, Y. H. Xia, Z. N. Wang, M. Z. Wang, Z. Y. Yang, X. L. Xu, Y. X. Geng, Y. Y. Zhao, C. Lin, W. J. Ma, J. Q. Yu, H. R. Wang, F. L. Liu, C. Y. He, B. Guo, P. Zhu, G. Q. Zhang, N. Y. Wang, Y. G. Ma, and X. Q. Yan, 197Au(γ, xn; x = 1 ∼ 9) reaction cross section measurements using laser-driven ultra-intense γ-ray source, arXiv:2209.1947 [nuclear, physics:physics] (2023).
  17. [17]H. Y. Lan, D. Wu, J. X. Liu, J. Y. Zhang, H. G. Lu, J. F. Lv, X. Z. Wu, W. Wu, Luo, and X. Q. Yan, Photonuclear production of nuclear isomers using bremsstrahlung induced laser-wakefield electrons, Nuclear Science and Techniques 34, 74 (2023).DOI
  18. [18]J. Magill, H. Schwoerer, F. Ewald, J. Galy, R. Schenkel, and R. Sauerbrey, Laser transmutation of iodine-129, Applied Physics B 77, 387 (2003).DOI
  19. [19]R. Takashima, S. Hasegawa, K. Nemoto, and K. Kato, Possibility of transmutation of 135Cs by ultratrense laser, Applied Physics Letters 86, 011501 (2004).
  20. [20]I. Pomerantz, E. McCary, A. R. Meadows, A. Arefiev, A. C. Bernstein, C. Chester, J. Cortez, M. E. Donovan, G. Dyer, E. W. Gaul, D. Hamilton, D. Kuk, A. C. Lestrade, C. Wang, T. Ditmire, and B. M. Hegelich, Ultrashort pulsed neutron source, Phys. Rev. Lett. 113, 184801 (2014).
  21. [21]M. M. Günther, O. N. Rosmej, P. Tavana, M. Gyrdymov, A. Skobliakov, A. Kantsyrev, Ş. Zähter, N. G. Borisenko, A. Pukhov, and N. E. Andreev, Forward-looking insights in laser-generated ultra-intense γ-ray and neutron sources for nuclear application and science, Nature Communications 13, 170 (2022).
  22. [22]P. Tavana, N. Bukharskii, M. Gyrdymov, U. Spillmann, Ş. Zähter, J. Cikhardt, N. G. Borisenko, P. Korneev, J. Jacoby, C. Spielmann, N. E. Andreev, M. M. Günther, and O. N. Rosmej, Ultra-high efficiency bremsstrahlung production in the interaction of direct laser-accelerated electrons with high-z material, Frontiers in Physics 11 (2023).DOI
  23. [23]K. W. D. Ledingham, I. Spencer, T. McCanny, R. P. Singhal, M. I. K. Santala, E. Clark, I. Watts, F. N. Beg, M. Zepf, K. Krushelnick, M. Tatarakis, A. E. Dangor, P. A. Norreys, R. Allott, D. Neely, R. J. Clark, A. C. Machacek, J. S. Wark, A. J. Cresswell, D. C. W. Sanderson, and J. Magill, Photoneutron physics when a multi-terawatt laser pulse interacts with solid targets, Phys. Rev. Lett. 84, 899 (2000).
  24. [24]J. Y. Zhang, D. Wu, H. Y. Lan, H. G. Lu, J. X. Liu, J. F. Lv, M. M. Z. Wang, and X. Q. Yan, Generation of medical isotopes 47Sc, 67Cu through laser-induced (γ, p) reaction, Nuclear Science and Techniques 35, 206 (2024).
  25. [25]R. H. Brazzle, O. V. Pravdivtseva, A. P. Meshik, and C. M. Hohenberg, Verification and interpretation of the i-xe chronometer, Geochimica et Cosmochimica Acta 63, 739 (1999).DOI
  26. [26]R. H. Gary, S. M. Bradley, S. Gopalan, N. G. Jitendra, and S. Sandeep, Stellar sources of the short-lived radionuclides in the early solar system, Geochimica et Cosmochimica Acta 73, 4922 (2009), the Chronology of Meteorites and the Early Solar System.
  27. [27]X. L. Hou, V. Hansen, A. Aldahan, G. Possnert, O. C. Lind, and G. L. Jujianene, A review on speciation of iodine-129 in the environmental and biological samples, Analytica Chimica Acta 632, 181 (2009).DOI
  28. [28]E. Brault, S. Vandenberghe, R. Van Holen, J. De Beenhouwer, S. Staelens, and I. Lemahieu, Comparison of image quality of different iodine isotopes (123I, 124I, and 131I), Cancer Biotherapy and Radiopharmaceuticals 22, 423 (2007).
  29. [29]B. E. Hertz and K. E. Schuller, Saul hertz, md (1905-1950): A pioneer in the use of radioactive iodine, Endocrine Practice 16, 713 (2010).DOI
  30. [30]M. Green, J. Lowe, M. Kadirvel, A. McMahon, N. Westwood, S. Chua, and G. Brown, Radiosynthesis of no-carrier-added [124I] iodobenzylguanidine for pet imaging of metastatic neuroblastoma, Journal of Radio-analytical and Nuclear Chemistry 311, 727 (2017).DOI
  31. [31]H. Herzog, L. Tellmann, S. M. Qaim, S. P. Stiepelberg, A. Schmid, and H. H. Coenen, PET quantitation and imaging of the non-pure positron-emitting iodine isotope 124I, Applied Radiation and Isotopes 56, 673 (2002).pubmed.ncbi.nlm.nih.gov/11993941
  32. [32]J. Schmitz, The production of [124I]iodine and [86Y]yttrium, European Journal of Nuclear Medicine and Molecular Imaging 38, 4 (2011).DOI
  33. [33]J. Robbins and A. B. Schneider, Thyroid cancer following exposure to radioactive iodine, Reviews in Endocrine and Metabolic Disorders 1, 197 (2000).DOI
  34. [34]T. Ferris, L. Carroll, S. Jenner, and O. Aboagye, Use of radioiodine in nuclear medicine—a brief overview, Journal of Labelled Compounds and Radiopharmaceuticals 64, 92 (2021).DOI
  35. [35]H. M. Park, 123I: Almost a designer radioiodine for thyroid scanning, Journal of Nuclear Medicine 43, 77 (2002).
  36. [36]S. K. GERARD and R. R. CAVALIERI, I-123 diagnostic thyroid tumor whole-body scanning with imaging at 6, 24, and 48 hours, Clinical Nuclear Medicine 27, 1 (2002).pubmed.ncbi.nlm.nih.gov/11805475
  37. [37]S. Qaim, Use of cyclotrons in medicine, Radiation Physics and Chemistry 71, 917 (2004).DOI
  38. [38]O. Artun and H. Aytekin, Calculation of excitation functions of proton, alpha and deuteron induced reactions for production of medical radioisotopes 122–125I, Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms 345, 1 (2015).
  39. [39]D. Cambula and B. Cambula, Cross-section calculations for the production of 123I and 124I radioisotopes via (p,n) and (p,2n) reactions using collective nuclear level density model, Nuclear Technology 209, 895 (2023).
  40. [40]P. Bzowski, D. Borys, K. Gorczewski, A. Chmura, K. Daszewska, I. Gorczewska, A. Kastelik-Hryniewiecka, M. Szydło, A. d’Amico, and M. Sokół, Efficiency of 124I radioisotope production from natural and enriched tellurium dioxide using 124Te(p,xn)124I reaction, EJNMMI Physics 9, 41 (2022).DOI
  41. [41]Y. Sheh, J. Koziorowski, J. Balatoni, C. Lom, J. R. Dahl, and R. D. Finn, Low energy cyclotron production and chemical separation of "no carrier added" iodine-124 from a reusable, enriched tellurium-124 dioxide/aluminum oxide solid solution target, Radiochimica Acta 88, 169 (2000).DOI
  42. [42]H. N. Wellman, V. J. Sodd, and J. F. Mack, Production and chemical development of a new ideal radioisotope of iodine—iodine-123, Frontiers of Nuclear Medicine/Aktuelle Nuklearmedizin , 19 (1971).DOI
  43. [43]A. Avetisyan, R. Avagyan, R. Kallakyan, G. Advalyan, N. Dobrovolsky, V. Gavalyan, I. Kerobyan, and G. Harutyunyan, Investigation of 123I production using electron accelerator, Nuclear Medicine and Biology 47, 44 (2017).
  44. [44]H. Naik, G. Kim, K. Kim, M. Zaman, and T. H. Nguyen, Flux-weighted average cross sections of medical isotopes in the 127I(γ, xn) reactions with the bremsstrahlung end-point energies of 50 and 70 MeV, Applied Radiation and Isotopes 156, 108842 (2020).DOI
  45. [45]G. Jonsson and K. Lindgren, Pion effects in the 127I(γ, xn) reactions of high multiplicity, Nuclear Physics A 141, 355 (1970).DOI
  46. [46]M. A. Allen, J. K. Boyd, R. S. Callin, H. Deruyter, K. R. Eppley, K. S. Fant, W. R. Fowkes, J. Haimson, H. A. Hoag, D. B. Hopkins, T. Houck, R. F. Koontz, T. L. Lavine, G. A. Loew, B. Mecklenburg, R. H. Miller, R. D. Ruth, R. D. Ryne, A. M. Sessler, A. E. Vlieks, J. W. Wang, G. A. Westenskow, and S. S. Yu, High-gradient electron accelerator powered by a relativistic klystron, Phys. Rev. Lett. 63, 2472 (1989).DOI
  47. [47]T. Bayram and S. Akkoyun, Determinations of 171Er half-life and some 171Tm transition energies, Nuclear Science and Techniques 29, 39 (2018).DOI
  48. [48]A. X. Li, C. Y. Qin, H. Zhang, S. Li, L. L. Fan, Q. S. Wang, T. J. Xu, N. W. Wang, L. H. Yu, Y. Xu, and et al., Acceleration of 60 MeV proton beams in the commissioning experiment of the sub-10 PW laser, High Power Laser Science and Engineering 10, e26 (2022).arxiv.org/abs/2207.07265
  49. [49]ORTEC, Gamma-X (GMX) N-type High Purity Germanium (HPGe) Coaxial Radiation Detectors (2025).
  50. [50]IEEE, IEEE standard test procedures for germanium gamma-ray detectors, IEEE Std 325-1996 (1997).
  51. [51]ORTEC, DSPec 50/50A and DSPec 50/502A Digital Signal Processing Gamma Spectrometers (2025).
  52. [52]ORTEC, Gamma Vision Gamma Spectroscopy (2025).
  53. [53]S. Sebastián, S. Roque, and B. Tania, Simulation of a hpge detector with geant4, Revista Politécnica 50, 7 (2022).DOI
  54. [54]S. Agostinelli, J. Allison, K. Amako, J. Apostolakis, H. Araujo, P. Arce, M. Asai, D. Axen, S. Banerjee, G. Barrand, F. Behner, L. Bellagamba, J. Boudreau, L. Broglia, A. Brunengo, H. Burkhardt, S. Chauvie, J. Chuma, R. Chytracek, G. Cooperman, G. Cosmo, P. Degtyarenko, A. Dell’Acqua, G. Depaola, D. Dietrich, R. Enami, A. Feliciello, C. Ferguson, H. Fesefeldt, G. Folger, F. Foppiano, A. Forti, S. Garelli, S. Gianni, R. Giannitrapani, D. Gibin, J. Gómez Cadenas, I. González, G. Gracia Abril, G. Greeniaus, W. Greiner, V. Grichine, A. Grossheim, S. Guatelli, P. Gumplinger, R. Hamatsu, K. Hashimoto, H. Hasui, A. Heikkinen, A. Howard, V. Ivanchenko, A. Johnson, F. W. Jones, J. Kallenbach, N. Kanaya, M. Kawabata, Y. Kawabata, M. Kawaguti, S. Kelner, P. Kent, A. Kimura, T. Kodama, R. Kokoulin, M. Kossov, H. Kurashige, E. Lamanna, T. Lampén, V. Lara, V. Lefebure, F. Lei, M. Liendl, W. Lockman, F. Longo, S. Magni, M. Maire, E. Medernach, K. Minamimoto, P. Mora de Freitas, Y. Morita, K. Murakami, M. Nagamatu, R. NatalIo, P. Nieminen, T. Nishimura, K. Ohtsubo, M. Okamura, S. O’Neale, Y. Oohata, K. Paech, J. Perl, A. Pfeiffer, M. G. Pia, F. Ranjard, A. Rybin, S. Sadilov, E. Di Salvo, G. Santin, T. Sasaki, N. Savvas, Y. Sawada, S. Scherer, S. Sei, V. Sirotenko, D. Smith, N. Starkov, H. Stoecker, J. Sulikimo, M. Takahata, S. Tanaka, E. Tcherniaev, E. Safai Tehrani, M. Tropeano, P. Truscott, H. Uno, L. Urban, P. Urban, M. Verderi, A. Walkden, W. Wander, H. Weber, J. Wellisch, T. Wenaus, D. Williams, D. Wright, T. Yamada, H. Yoshida, and D. Zschiesche, Geant4—a simulation toolkit, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 506, 250 (2003).DOI
  55. [55]J. Allison, K. Amako, J. Apostolakis, H. Araujo, P. Arce Dubois, M. Asai, G. Barrand, R. Capra, S. Chauvie, R. Chytracek, G. Cirrone, G. Cooperman, G. Cosmo, G. Cuttone, G. Daquino, M. Donszelmann, M. Dressel, G. Folger, F. Foppiano, J. Generowicz, V. Grichine, S. Guatelli, P. Gumplinger, A. Heikkinen, I. Hrivnacova, A. Howard, S. Incerti, V. Ivanchenko, T. Johnson, F. Jones, T. Koi, R. Kokoulin, M. Kossov, H. Kurashige, V. Lara, S. Larsson, F. Lei, O. Link, F. Longo, M. Maire, A. Mantero, B. Masciolino, I. McLaren, P. Mendez Lorenzo, K. Minamimoto, K. Murakami, P. Nieminen, L. Pandola, S. Parlati, L. Peralta, J. Perl, A. Pfeiffer, M. Pia, A. Ribon, P. Rodrigues, G. Russo, S. Sadilov, G. Santin, T. Sasaki, D. Smith, N. Starkov, S. Tanaka, E. Tcherniaev, B. Tome, A. Trindade, P. Truscott, L. Urban, M. Verderi, A. Walkden, J. Wellisch, D. Williams, D. Wright, and H. Yoshida, Geant4 developments and applications, IEEE Transactions on Nuclear Science 53, 270 (2006).
  56. [56]Supplemental Materials: Production of Iodine Isotopes via Ultra-intense Laser Driven Photonuclear Reactions (2025).
  57. [57]ANSYS Students 2025r1. (2025).
  58. [58]J. L. Henares, P. Puyuelo-Valdes, F. Hannachi, T. Cecotti, M. Ereft, F. Gobet, L. Lancia, J.-R. Marquès, J. J. Santos, M. Versteegen, and M. Tarisien, Development of gas jet targets for laser-plasma experiments at near-critical density, Review of Scientific Instruments 90, 063302 (2019).DOI
  59. [59]Q. S. Liu, B. Guo, B. Z. Zhao, M. J. Ma, X. H. Ma, C. Lv, X. H. Meng, J. Zhang, X. N. Ban, Z. Wang, X. F. Xi, B. X. Tian, and C. Y. He, The Effect of multiple parameters on the supersonic gas-jet target characteristics for laser wakefield acceleration, Nuclear Science and Techniques 32, 75 (2021).DOI
  60. [60]J. Derouillat, A. Beck, F. Pérez, T. Vinci, M. Chiaramello, A. Grassi, M. Flé, G. Bouchard, I. Plotnikov, N. Aunai, J. Dargent, C. Riconda, and M. Grech, Smilei : A collaborative, open-source, multipurpose particle-in-cell code for plasma simulation, Computer Physics Communications 222, 351 (2018).
  61. [61]A. F. Lifschitz, X. Davoine, E. Lefebvre, J. Faure, C. Réchatin, and V. Malka, Particle-in-cell modelling of laser-plasma interaction using fourier decomposition, Journal of Computational Physics 228, 1803 (2009).
  62. [62]F. Massimo, A. Beck, J. Derouillat, M. Grech, M. Lobet, F. Pérez, I. Zemzemi, and A. Specka, Efficient start-to-end 3D envelope modeling for two-stage laser wakefield acceleration experiments, Plasma Physics and Controlled Fusion 61, 124001 (2019).DOI
  63. [63]Thermophysical Properties of Fluid Systems (2025).
  64. [64]S. P. D. Mangles, B. R. Walton, M. Tzoufras, Z. Najmudin, R. J. Clarke, A. E. Dangor, R. G. Evans, S. Fritzler, A. Gopal, C. Hernandez-Gomez, W. B. Mori, W. Rozmus, M. Tatarakis, A. G. R. Thomas, F. S. Tsung, M. S. Wei, and K. Krushelnick, Electron acceleration in cavitated channels formed by a petawatt laser in low-density plasma, Phys. Rev. Lett. 94, 245001 (2005).DOI
  65. [65]Z. Najmudin, K. Krushelnick, M. Tatarakis, E. L. Clark, C. N. Danson, V. Malka, D. Neely, M. I. K. Santala, and A. E. Dangor, The effect of high intensity laser propagation instabilities on channel formation in underdense plasmas, Physics of Plasmas 10, 438 (2003).
  66. [66]G. Boutoux, N. Rabhi, D. Batani, A. Binet, J.-E. Ducret, K. Jakubowska, J.-P. Nègre, C. Reverdin, and I. Thfoin, Study of imaging plate detector sensitivity to 5-18 MeV electrons, Review of Scientific Instruments 86, 113304 (2015).DOI
  67. [67]A. Koning and D. Rochman, Modern nuclear data evaluation with the TALYS code system, Nuclear Data Sheets 113, 2841 (2012).DOI
  68. [68]P. Mohr, K. Vogt, M. Babilon, J. Enders, T. Hartmann, C. Hutter, T. Rauscher, S. Volz, and A. Zilges, Experimental simulation of a stellar photon bath by bremsstrahlung: the astrophysical γ-process, Physics Letters B 488, 127 (2000).DOI
  69. [69]National Nuclear Data Center, Brookhaven National Laboratory (2025).
  70. [70]G. G. Jonsson and B. Forkman, (γ, xn) reactions in 127I, Nuclear Physics A 107, 52 (1968).DOI
  71. [71]R. J. Debs, J. T. Eisinger, A. W. Fairhall, I. Halpern, and H. G. Richter, Yields of photonuclear reactions with 320-MeV x-rays. I. experimental results, Phys. Rev. 97, 1325 (1955).DOI

Paper details

vlnc:W_yccy92sm
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 0

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents