WorksComputer Science
CT-Navigator: Towards Interpretable and Generalizable CT Understanding through Agentic Perception and Tool-Invocation
Abstract
Clinical computed tomography (CT) interpretation inherently requires progressive visual exploration, where radiologists navigate from whole scans to individual slices and regions of interest and interact with external tools when necessary. However, existing 3D medical multimodal large language models (MLLMs) typically connect a specialized 3D visual encoder to a language model, without fully leveraging the native 2D visual and agentic capabilities of generalist MLLMs. Trained on large-scale one-hop CT instruction-following data, these models also have limited ability to perform iterative reasoning and explicitly ground their conclusions in visual evidence, limiting their support for traceable CT interpretation. To solve these problems, we propose agentic perception as an alternative paradigm inspired by radiologists' interpretation workflows. We introduce CT-Navigator, a framework that harnesses generalist MLLMs' 2D visual and agentic capabilities to progressively ground CT interpretation in explicit, traceable visual evidence through hierarchical visual exploration and radiology tool invocation. To build these capabilities, we curate 8,904 visual chain-of-thought (V-CoT) trajectories for cold-start agentic supervised fine-tuning. We then optimize the policy through reinforcement learning on 33,219 questions, with data selection and dynamic rollout sampling prioritizing informative learning signals. Finally, we introduce CTNavi-Bench, a 3D CT visual question answering benchmark comprising 7,000 questions spanning anatomical regions throughout the human body. CT-Navigator achieves 79.50% accuracy on CTNavi-Bench, surpassing the strongest baseline by 17.59%, and demonstrates strong generalization across three external CT benchmarks. The code, model, and benchmark will be released on \href{https://github.com/fyb99/ct_navigator}{GitHub}.
Introduction
Computed tomography (CT) is one of the most widely used non-invasive medical imaging modalities for clinical diagnosis, disease monitoring, and post-treatment follow-up [14]. It provides volumetric anatomical information that enables clinicians to inspect organs and surrounding structures within human bodies. In clinical practice, as illustrated in Figure 1, radiologists actively navigate CT volumes, progressing from a scan-level overview to key slices and clinically relevant regions of interest (ROIs) [8]. They also interact with radiology tools to localize anatomical structures and measure findings such as cysts and lung nodules. This iterative interpretation paradigm is significantly labour-intensive and time-consuming. As the number of CT examinations grows worldwide, radiologists face an increasingly heavy workload [5], underscoring the importance of reliable AI-assisted systems to facilitate CT interpretation [24, 33].

Figure 1. Motivation for CT-Navigator. Existing 3D medical MLLMs typically couple a 3D visual encoder with a language model to generate answers directly from CT volumes, providing limited traceable visual reasoning. Inspired by the progressive visual navigation workflow of radiologists in clinical practice, we propose CT-Navigator, which adapts generalist MLLMs for CT understanding in an agentic perception setting.
Recent advances in medical multimodal large language models (MLLMs) [17, 38, 40] offer promising opportunities for AI-assisted CT interpretation. Several CT-oriented 3D MLLMs have been designed for tasks such as visual question answering (VQA) and radiology report generation [2, 39]. Most existing 3D MLLMs connect a specialized 3D visual encoder to a language model to accommodate volumetric inputs and perform large-scale training subsequently. In clinical practice, however, radiologists inspect 2D slices rather than directly view 3D volumes, combining visual exploration with external tool-interacting. This clinical workflow motivates a new paradigm for CT understanding in which generalist MLLMs progressively inspect 2D slices and local views rather than directly processing 3D volumes. Aligned with radiologists’ clinical interpretation workflows, this paradigm explicitly connects diagnostic conclusions to supporting visual evidence, making the interpretation process explicit and traceable. More importantly, this paradigm can harness the native perception, planning, and tool-use capabilities of generalist 2D MLLMs, which benefit from large-scale multimodal pre-training and dedicated agentic training.
Based on this paradigm, we reformulate 3D CT understanding as an agentic perception problem and adapt generalist MLLMs to actively explore CT slices and ground their interpretation in explicit, traceable visual evidence. As illustrated in Figure 1, this formulation follows the progressive visual evidence accumulation process in clinical practice. We introduce CT-Navigator, an agentic framework for 3D CT interpretation through hierarchical agentic perception. CT-Navigator first examines a montage overview of sampled CT slices, then progressively identifies and inspects relevant slices and ROIs, guided by the clinical question and its evolving visual observations. We further equip CT-Navigator with a radiology toolkit to gather complementary evidence for CT interpretation. Throughout this process, CT-Navigator proactively decides where to inspect and how to acquire visual evidence before reaching a conclusion, producing traceable trajectories.
Conventional CT instruction-tuning datasets primarily consist of VQA pairs, providing solely answer-level supervision with limited guidance for visual evidence acquisition and tool invocation. To develop these agentic capabilities, we curate 8,904 high-quality visual chain-of-thought (V-CoT) trajectories combining human-annotated visual navigation with LLM-synthesized tool interactions. These trajectories provide explicit supervision for progressive visual perception and tool invocation, enabling efficient adaptation of generalist MLLMs through cold-start supervised fine-tuning (SFT). We then optimize the model policy through agentic reinforcement learning (RL) to learn generalizable strategies for CT interpretation. To support efficient RL training, we introduce a dynamic data sampling strategy that prioritizes questions that provide informative feedback for policy improvement.
Finally, since most existing 3D CT benchmarks focus on specific anatomical regions, we introduce CTNavi-Bench, a clinical finding grounded benchmark comprising 7,000 questions across anatomical regions throughout the body. Experiments on CTNavi-Bench and three external CT benchmarks demonstrate that CT-Navigator outperforms existing MLLMs and exhibits strong out-of-distribution generalization. Further ablation studies show consistent gains of 20% over the base model across 4 benchmarks, demonstrating the effectiveness of the agentic perception paradigm and our training strategy. Our technical contributions are summarized as follows:
Hierarchical Agentic Perception. We reformulate 3D CT understanding as an agentic perception problem and introduce CT-Navigator, which adapts generalist MLLMs through hierarchical exploration of key slices and ROIs, along with radiology tool invocation.
V-CoT Curation & Data-efficient Training. We curate 8,904 agentic V-CoT trajectories to provide process-level supervision for visual navigation and tool invocation. We develop a two-stage training strategy combining cold-start SFT with RL, using dynamic data sampling during RL to support efficient policy optimization.
Benchmark Construction. We construct CTNavi-Bench to evaluate CT understanding across anatomical regions and levels of granularity.
Experiments. Comprehensive experiments on CTNavi-Bench and three external CT benchmarks demonstrate superior performance and strong out-of-distribution generalization of CT-Navigator.
Related Work
Medical MLLMs
Vision–language learning aims to integrate visual and textual information into unified representations for multimodal understanding. Early approaches primarily explored multimodal alignment between image features and text features [10, 36]. Subsequently, CLIP-style [30] methods adopted contrastive pretraining on large-scale medical image-caption corpus [22, 45], facilitating transferable visual representations. With the recent advancement of MLLMs [1, 23], substantial progress has been made in building medical MLLMs [19, 34], which support a broad range of tasks such as VQA and radiology report generation. However, these models are primarily designed for 2D medical images and offer limited support for interpreting volumetric scans. To narrow this gap, several works have explored extending MLLMs to 3D medical imaging domain. For example, RadFM [39] incorporates both 2D and 3D image–text pairs into radiological pretraining. M3D-LaMed [2] brings retrieval, question answering, and segmentation into a unified 3D MLLM framework. More recently, OmniCT [21] strengthens spatial representations across slices and volumes using spatial-consistency constraints and organ-level alignment. Photon [9] focuses on efficient volumetric processing by visual token pruning. Despite these advances, existing methods rely heavily on large-scale instruction tuning, which may encourage memorization of response patterns rather than explicitly ground their responses and reasoning in relevant visual evidence.
3D CT Understanding Benchmark
The development of 3D MLLMs has prompted increasing efforts to benchmark 3D medical understanding. As summarized in Table 1, M3D-Bench [2] covers a broad range of tasks, including image–text retrieval, VQA, and segmentation. 3D-RAD [11] focuses on CT-based diagnostic reasoning, with questions addressing abnormality recognition and longitudinal assessment. DeepTumorVQA [6] introduces a large-scale benchmark with 29 medical tasks of 4 dimensions for abdominal CT interpretation. Nevertheless, two limitations remain within these established benchmarks. First, template-based question generation from a limited set of CT volumes may introduce content redundancy and overrepresent tasks that do not reflect clinical practice. For example, DeepTumorVQA includes quantitative questions derived from segmentation masks, such as HU value ranges, which may place disproportionate emphasis on measurements that are not routinely documented in radiology reports. Second, existing benchmarks primarily provide large collections of repetitive VQA pairs but lack interpretable V-CoT annotations to guide visual reasoning. These answer-level annotations provide limited guidance on how to progressively acquire relevant evidence, potentially encouraging memorization of response patterns rather than active visual reasoning.
Table 1. Comparison of existing 3D CT VQA benchmarks in terms of train/test samples, anatomy coverage and V-CoT annotations.
Benchmark
Benchmark Establishment
As summarized in Table 1, most existing 3D medical VQA benchmarks focus on specific anatomical regions. To address this limitation, we construct CTNavi-Bench for evaluating CT understanding across multiple anatomical regions.
Data Curation: For data collection, we collaborated with a top-tier medical institution to collect CT examinations from real-world clinical visits, which provide scans covering different anatomical regions with their associated radiology reports. After filtering low-quality data, we collected 14,853 CT scans from 11,215 patients in total. During the data partitioning stage, we strictly followed a patient-level protocol to avoid patient-level data leakage, resulting in 12,011 and 2,842 scans for building training and evaluation corpus. Our work is conducted according to the principles of the Declaration of Helsinki and all the data are de-identified.
Benchmark Construction: Furthermore, we construct VQA samples from the radiology reports associated with volumetric scans. The construction pipeline includes data-quality filtering, QA generation, and balanced sampling. The overall pipeline is illustrated in Figure 2-(a). Specifically, we initially exclude scans that fail to meet predefined quality criteria such as scans with very few slices or unparsable reports. Then, we employ GPT-5.6-Sol to extract clinically meaningful findings from each report and transform them into multiple-choice (MCQ) or open-ended questions. To build comprehensive assessment dimensions, we prompt the LLM to generate questions spanning four complementary aspects, from global perception to quantitative measurement. The four question categories include:
Figure 2. Overview of CTNavi-Bench construction and agentic trajectory curation. (a) Pipeline for report-grounded QA generation and quality control. (b) Question distribution by category and anatomical region. (c) Pipeline for visual navigation annotation by radiologists. (d) Pipeline for LLM-based agentic trajectory synthesis. (e) Example trajectories showing visual navigation and tool interactions.
Characterization: Questions examine qualitative attributes of identified findings.
Detection: Questions assess the presence of findings or identify abnormalities within an anatomical region.
Localization: Questions assess the location of identified findings such as laterality or organ compartments.
Quantification: Questions require explicit counting or measurement of anatomical structures and lesions.
Finally, human experts are involved to review the clarity and clinical correctness after this generation step. We then apply selective sampling to balance question categories and clinical content for maximizing question diversity. Meanwhile, we balance answer options in MCQ and maintain approximately equal proportions of MCQ and open-ended questions in final benchmark. Ultimately, we sample a compact set of 7,000 VQA pairs that preserves broad diversity and clinical relevance.
CoT Annotation
The training corpora in existing 3D CT VQA benchmarks primarily consist of VQA pairs, without explicit supervision on how to acquire relevant visual evidence. This outcome-oriented supervision alone provides limited guidance for traceable clinical reasoning. Therefore, we curate 8,904 agentic V-CoTs from the training corpus of CTNavi-Bench that integrate visual exploration and tool interactions.
We collect radiologist annotations about visual exploration through a web-based CT viewer that supports scrolling through slices, adjusting window settings, and zooming into ROI. As shown in Figure 2(c), annotation proceeds in two stages. In the first stage, 10 junior radiologists independently review CT scans to inspect the abnormalities documented in original report. For each reported finding, they select key slices, choose appropriate window settings, and draw bounding boxes around the relevant regions. Each annotation records the slice index, window setting, bounding box coordinates, and accompanying findings and reasoning descriptions. In the second stage, four senior radiologists jointly review the individual annotations and retain only cases on which they reach consensus. We then link each question to the reviewed annotations through its referenced finding and use these annotations to guide V-CoT generation. Specifically, starting from a slice montage, each trajectory proceeds to select relevant slices with appropriate window settings, inspect marked regions through necessary zooming operations, and reason from the gathered visual evidence to answer the question.
Beyond visual navigation and CT slice inspection, MLLMs can use external tools such as retrieval and quantitative measurement tools to obtain additional evidence. We generate trajectories that supervise this capability using GPT-5.6-Sol. Specifically, GPT-5.6-Sol receives a question and an initial CT slice montage with access to the radiology toolkit described in § 4.2. Along the reasoning process, the model reasons over the available evidence to decide whether and how to invoke a tool. The returned output informs subsequent reasoning and tool selection until the model produces a final answer. We retain only coherent trajectories that include at least one tool invocation and produce a correct answer at the end. MCQ questions are evaluated by matching the predicted and reference options, while open-ended questions are evaluated by Qwen3.5-397B-A17B [28] for semantic consistency with the reference answers. In total, we collect 8,904 V-CoT trajectories. Radiologist-annotated trajectories supervise progressive visual perception, while GPT-generated trajectories complement this supervision by illustrating how to acquire and integrate evidence through external tools.
Methodology
Framework Overview
We reformulate 3D CT understanding as an agentic perception problem. Specifically, given a question and a CT volume , CT-Navigator initially receives and a montage image consisting of 64 uniformly sampled slices from . The montage provides a global overview in a 2D format accessible to general-purpose MLLMs. Guided by the question and its evolving observations, CT-Navigator progressively examines relevant clips, slices, and ROIs, while invoking specialized tools available in the radiology toolkit to gather complementary evidence.
Following previous agentic MLLMs [7, 26, 27], CT-Navigator follows a ReAct loop [43] that interleaves reasoning, actions, and observations. Let denote the initial context and denote the interaction history before step . The model policy generates a reasoning step and an action conditioned on this history:
where contains the available tool calls and denotes final-answer actions. For a tool call , the system executes with arguments on the input context and appends the returned observation to the history:
The updated history guides subsequent reasoning and action selection until the model selects an action in and synthesizes the accumulated evidence into its final answer.
Radiology Toolkit
The initial montage provides global anatomical context but may omit details needed for further inspection. We equip CT-Navigator with six radiology tools for visual navigation and complementary evidence acquisition. The model selects tools based on the question and its history context and uses these tool outputs to inform further inspection or produce its final answer.
Slice selection. The model requests one or more slice indices from the original input montage overview to inspect a suspected finding. These may include slices absent from the initial montage. The tool assembles the requested slices into a new montage with each slice displayed at pixels. This supports progressive localization from a global overview to key slices that best show the finding.
Window display adjustment. In clinical practice, CT windowing adjusts the displayed attenuation range to emphasize different tissues and findings. CT-Navigator can choose among five window presets for brain, chest, mediastinum, abdomen, and bone. We incorporate the window setting as an argument to visual tools such as slice selection to reduce interaction turns and token overhead. The requested slices are rendered under the chosen window before being returned for inspection.
Region magnifier. The region magnifier enables closer inspection of a finding within a CT slice. Following the zoom-in operation in DeepEyes [16], the model specifies the region using a bounding box . The tool returns two complementary views in one call: the original slice with the box highlighted and an enlarged crop of the selected region. The crop allows detailed inspection of the finding’s shape and margins, while the marked slice retains its location relative to global anatomy.
Anatomy segmentation. The segmentation tool uses VISTA3D [15] to delineate anatomical structures requested by the model. It returns the original CT image with the segmented region highlighted and a separate ROI view. The highlighted image identifies the target within the surrounding anatomy, while the ROI allows the model to inspect its shape and boundaries in detail.
Cross-modal retrieval. Retrieval-based [7, 18] tools can enhance MLLM reasoning by supplying relevant external knowledge and exploit their strong in-context learning capabilities. Motivated by this, we equip CT-Navigator with a cross-modal retrieval tool that provides annotated CT slice examples as references during interpretation. We construct the retrieval corpus from representative slices in our training set and additional examples from DeepLesion [41]. Each entry contains a CT slice, a bounding box marking the finding, and a descriptive caption. CT-Navigator formulates a text query based on its current observations. We encode the query and corpus captions as and using Qwen3-Embedding-0.6B [47]. We rank entries by cosine similarity and return the three highest-ranked slices with their findings highlighted by a rectangle and captions attached.
Measurement. The measurement toolkit provides quantitative evidence for assessing organ size, tissue attenuation, and pulmonary nodule dimensions. For organ measurement, the model specifies the target organs and the tool applies VISTA3D [15] to obtain their segmentation masks. It then computes each organ’s volume, length, width, and attenuation in Hounsfield units (HU). Additionally, we deploy a dedicated detector to localize pulmonary nodules for measuring their sizes. The detector is an nnDetection model [3] trained on public datasets [25, 31, 35], with its encoder initialized from nnFoundation [13]. It predicts candidate bounding boxes in chest CT. We use a VISTA3D lung mask to filter out candidates outside the lungs, then return the estimated physical sizes of the retained nodules.
Learning Objective
We train CT-Navigator in two stages: cold-start SFT followed by agentic RL.
Cold-start SFT. We first fine-tune the model on the curated V-CoT dataset to establish foundational capabilities in hierarchical visual perception and tool invocation. At step of trajectory , the history contains the question, initial montage, and preceding interactions. We supervise the target model response by minimizing
RL data sampling. To improve RL efficiency, we prioritize questions that provide informative feedback for policy optimization. The candidate pool consists of 72,256 training questions not used for SFT. As illustrated in Figure 3-(a), the SFT model generates four trajectories per question at a high sampling temperature. We group questions by the number of correct answers and adjust their sampling proportions. Questions answered correctly in all four attempts are substantially downsampled because they offer little variation in answer correctness. Finally, this selection yields 33,219 questions for RL training.
Figure 3. Overview of CT-Navigator. (a) Cold-start SFT on V-CoT trajectories and RL data sampling guided by four high-temperature rollouts per question. (b) Agentic RL training with multi-turn tool interactions, optimized using a hybrid reward. (c) An example trajectory generated from CT-Navigator interleaving reasoning with multiple tools before producing the final answer.
Agentic RL. We optimize the policy using GSPO [48] through multi-turn interactions with the radiology toolkit, as shown in Figure 3-(b). During training, we adopt the dynamic sampling strategy from DAPO [44] to prioritize rollout groups with nonzero reward variance, ensuring informative feedback for policy updates. For a trajectory , the total reward is . The format reward checks compliance with the interaction protocol. The performance reward compares the final answer against the reference through option matching for MCQ and an LLM judge for open-ended questions. Figure 3-(c) illustrates a trajectory that gathers evidence through successive tool calls before answering.
Experiments
Implementation Details
We initialize CT-Navigator from Qwen3.5-9B [28] and run cold-start SFT on 8 NVIDIA H200 GPUs for 1 epoch using a learning rate of and a global effective batch size of 32. For RL, we allocate 40 H200 GPUs for training, with 16 for rollout generation and 24 for policy updates. We train the model using a learning rate of , a global effective batch size of 384 and a rollout group size of 4.
Main Results
Results on CTNavi-Bench. Table 2 compares our CT-Navigator with 18 generalist, medical, and 3D medical MLLMs. Generalist baselines include GPT-5.6-Luna and GPT-5.6-Sol, InternVL3 [49], and the Qwen series [29, 32, 42]. We also evaluate medical MLLMs including Hulu-Med [17], Lingshu [40], and HealthGPT [20], alongside 3D medical MLLMs including M3D [2], RadFM [39], Merlin [4], OmniCT [21], and Photon [9]. As summarized in Table 2, our model achieves an overall accuracy of 79.50%, outperforming the strongest baseline GPT-5.6-Sol by 17.59%. It achieves the highest semantic accuracy in all four question categories. In particular, open-ended localization and quantification accuracies reach 69.83% and 42.43%, exceeding the best competing results by 35.09% and 17.77%, respectively.
| Model | Multiple-choice Questions | Open-ended Questions | Avg. | ||||||||||
| Chara. Acc. | Det. Acc. | Loc. Acc. | Quan. Acc. | Chara. Acc. | Chara. BSF | Det. Acc. | Det. BSF | Loc. Acc. | Loc. BSF | Quan. Acc. | Quan. BSF | ||
| Closed-source Generalist MLLMs | |||||||||||||
| GPT-5.6-Luna | 72.73 | 81.82 | 63.66 | 49.87 | 68.82 | 89.96 | 78.42 | 93.17 | 34.29 | 90.29 | 18.77 | 89.16 | 59.44 |
| GPT-5.6-Sol | 73.49 | 81.27 | 68.34 | 53.88 | 72.98 | 90.79 | 85.76 | 93.68 | 34.74 | 89.53 | 17.40 | 89.75 | 61.91 |
| Open-source Generalist MLLMs | |||||||||||||
| InternVL3-8B | 48.85 | 64.07 | 49.83 | 38.97 | 47.05 | 89.51 | 54.55 | 93.08 | 25.26 | 92.85 | 2.75 | 90.55 | 42.13 |
| Qwen3-VL-8B | 53.23 | 55.42 | 48.11 | 46.99 | 43.54 | 88.46 | 50.82 | 83.34 | 18.63 | 88.07 | 7.38 | 89.67 | 41.03 |
| Qwen3.5-9B | 51.37 | 72.62 | 49.26 | 44.61 | 49.67 | 83.27 | 70.32 | 82.49 | 12.00 | 85.12 | 13.02 | 87.44 | 46.06 |
| Qwen3.6-27B | 61.66 | 59.26 | 43.09 | 47.99 | 47.48 | 83.58 | 54.00 | 82.59 | 18.17 | 85.70 | 21.03 | 87.15 | 44.54 |
| Qwen3.8-27B | 69.44 | 61.56 | 51.31 | 48.25 | 51.53 | 84.88 | 59.80 | 82.92 | 19.66 | 86.14 | 22.28 | 88.02 | 48.53 |
| Medical MLLMs | |||||||||||||
| Hulu-Med-7B | 70.21 | 73.06 | 61.83 | 52.88 | 57.99 | 92.85 | 81.60 | 96.54 | 20.11 | 88.23 | 21.40 | 91.52 | 55.61 |
| Hulu-Med-32B | 77.88 | 77.77 | 63.89 | 54.89 | 58.64 | 90.82 | 80.18 | 95.62 | 20.69 | 87.53 | 24.66 | 88.38 | 58.06 |
| Lingshu-7B | 61.66 | 61.88 | 54.97 | 47.99 | 44.31 | 87.37 | 63.53 | 88.28 | 15.09 | 87.20 | 14.89 | 90.22 | 46.11 |
| Lingshu-32B | 69.66 | 63.31 | 58.06 | 52.76 | 50.55 | 87.71 | 60.46 | 88.30 | 17.60 | 88.41 | 13.39 | 89.65 | 48.83 |
| HealthGPT-8B | 72.07 | 59.58 | 63.09 | 54.51 | 51.53 | 85.34 | 73.82 | 88.53 | 14.29 | 85.73 | 17.40 | 87.18 | 51.40 |
| 3D Medical MLLMs | |||||||||||||
| M3D-Phi-3-4B | 56.63 | 67.58 | 53.03 | 33.21 | 49.56 | 89.14 | 62.98 | 89.48 | 19.31 | 89.86 | 7.01 | 90.79 | 44.51 |
| M3D-Llama-2-7B | 37.79 | 62.98 | 42.40 | 29.20 | 39.93 | 86.84 | 66.16 | 83.17 | 15.09 | 89.80 | 3.88 | 88.88 | 37.94 |
| RadFM-14B | 26.83 | 51.48 | 21.94 | 24.31 | 46.83 | 92.42 | 64.95 | 94.45 | 17.71 | 92.26 | 7.63 | 91.50 | 33.40 |
| Merlin | 40.96 | 52.57 | 30.51 | 15.41 | 35.89 | 91.32 | 56.74 | 92.66 | 19.43 | 92.56 | 10.51 | 88.86 | 33.49 |
| OmniCT-7B | 71.74 | 64.18 | 58.63 | 45.74 | 54.92 | 87.56 | 72.95 | 89.48 | 16.23 | 85.72 | 22.40 | 87.44 | 51.54 |
| Photon-3B | 57.17 | 67.25 | 53.37 | 51.38 | 42.78 | 88.68 | 67.25 | 88.27 | 10.63 | 87.73 | 7.26 | 88.55 | 45.27 |
| CT-Navigator | 90.47 | 96.28 | 79.09 | 75.94 | 81.62 | 95.55 | 94.85 | 97.22 | 69.83 | 92.05 | 42.43 | 88.96 | 79.50 |
Table 2. Comparison results on CTNavi-bench. Multiple-choice questions are evaluated using accuracy (%). Open-ended questions are evaluated using LLM-judged accuracy (%) and raw BERTScore-F1 (BSF). Avg. denotes overall accuracy.
Results on External Benchmarks. Table 3 evaluates CT-Navigator on 3 external benchmarks including Merlin [4], CT-RATE [12], and DeepTumorVQA [6] beyond CTNavi-Bench in a zero-shot setting. Note that we use GPT-5.6-Sol for building QA pairs in Merlin and CT-RATE from their official released scans and reports. Following prior work [37], we construct balanced evaluation subsets of 4,000 questions per benchmark by reducing redundancy and answer-position bias. As summarized in Table 3, our model achieves overall accuracies of 60.35%, 68.88%, and 59.88%, exceeding the strongest competing results by 4.60%, 3.48%, and 7.40% without any training on these benchmarks. For DeepTumorVQA, this comparison excludes Photon, whose dataset-specific fine-tuning results are reported as a specialist reference. These consistent gains across three external subsets demonstrate the model’s strong generalization ability beyond CTNavi-Bench.
| Model | Merlin | CT-RATE | DeepTumorVQA | ||||||||||||
| Char. | Recog. | Loc. | Meas. | Avg. | Char. | Recog. | Loc. | Meas. | Avg. | Recog. | Meas. | Vis.R. | Med.R. | Avg. | |
| Closed-source Generalist MLLMs | |||||||||||||||
| GPT-5.6-Luna | 54.50 | 77.80 | 57.60 | 33.10 | 55.75 | 72.90 | 84.90 | 59.10 | 44.70 | 65.40 | 71.84 | 40.27 | 39.99 | 24.94 | 49.30 |
| GPT-5.6-Sol | 47.00 | 71.30 | 59.90 | 39.00 | 54.30 | 64.20 | 79.20 | 61.30 | 41.20 | 61.48 | 73.17 | 32.06 | 40.50 | 39.51 | 49.58 |
| Open-source Generalist MLLMs | |||||||||||||||
| InternVL3-8B | 30.90 | 65.10 | 42.40 | 22.50 | 40.23 | 44.10 | 67.70 | 37.10 | 20.30 | 42.30 | 83.52 | 29.92 | 39.32 | 41.23 | 52.38 |
| Qwen3-VL-8B | 33.70 | 57.50 | 45.30 | 35.00 | 42.88 | 50.50 | 57.20 | 41.60 | 39.00 | 47.08 | 64.01 | 30.60 | 39.02 | 37.53 | 45.45 |
| Qwen3.5-9B | 30.90 | 57.00 | 32.80 | 23.80 | 36.13 | 53.90 | 63.70 | 43.00 | 28.10 | 47.18 | 44.49 | 29.92 | 38.58 | 41.23 | 38.93 |
| Qwen3.6-27B | 36.50 | 56.40 | 42.70 | 32.90 | 42.13 | 57.80 | 65.30 | 44.00 | 35.60 | 50.68 | 83.96 | 22.61 | 32.59 | 38.02 | 48.30 |
| Qwen3.8-27B | 44.50 | 56.10 | 44.70 | 22.90 | 42.05 | 66.20 | 62.50 | 48.70 | 26.50 | 50.98 | 76.20 | 30.37 | 41.98 | 42.47 | 51.03 |
| Medical MLLMs | |||||||||||||||
| Hulu-Med-7B | 57.60 | 72.40 | 48.50 | 24.50 | 50.75 | 58.50 | 84.80 | 50.00 | 27.20 | 55.13 | 84.85 | 27.56 | 33.11 | 30.86 | 49.15 |
| Hulu-Med-32B | 55.80 | 73.60 | 45.80 | 37.20 | 53.10 | 64.80 | 80.50 | 52.80 | 47.90 | 61.50 | 84.63 | 30.60 | 37.99 | 29.14 | 51.23 |
| Lingshu-7B | 48.30 | 61.40 | 45.60 | 27.60 | 45.73 | 56.20 | 62.60 | 45.70 | 31.40 | 48.98 | 85.29 | 31.27 | 40.35 | 29.88 | 52.48 |
| Lingshu-32B | 47.70 | 61.30 | 45.10 | 31.50 | 46.40 | 61.60 | 64.30 | 51.20 | 37.40 | 53.63 | 71.18 | 39.15 | 40.58 | 27.90 | 49.33 |
| HealthGPT-8B | 48.90 | 59.60 | 47.80 | 18.70 | 43.75 | 55.60 | 69.00 | 56.80 | 26.80 | 52.05 | 82.26 | 27.11 | 34.07 | 32.10 | 48.63 |
| 3D Medical MLLMs | |||||||||||||||
| M3D-Phi-3-4B | 44.00 | 76.70 | 44.00 | 18.50 | 45.80 | 42.00 | 75.10 | 41.60 | 16.80 | 43.88 | 50.63 | 25.98 | 30.52 | 37.53 | 37.03 |
| M3D-Llama-2-7B | 36.60 | 43.90 | 38.40 | 21.40 | 35.08 | 27.20 | 56.00 | 37.70 | 16.10 | 34.25 | 8.87 | 22.16 | 27.57 | 35.80 | 20.88 |
| RadFM-14B | 24.70 | 52.20 | 23.80 | 23.80 | 31.13 | 25.00 | 52.20 | 22.70 | 25.00 | 31.23 | 42.57 | 24.52 | 30.38 | 37.28 | 33.90 |
| Merlin | 28.80 | 49.90 | 32.10 | 19.30 | 32.53 | 32.80 | 49.20 | 28.40 | 17.90 | 32.08 | 49.08 | 22.95 | 29.64 | 35.80 | 35.35 |
| OmniCT-7B | 55.70 | 64.70 | 46.00 | 18.40 | 46.20 | 55.90 | 72.20 | 48.70 | 19.00 | 48.95 | 62.97 | 24.07 | 30.60 | 30.62 | 40.10 |
| Photon-3B† | 45.90 | 55.20 | 41.60 | 41.20 | 45.98 | 48.10 | 61.70 | 42.20 | 29.50 | 45.38 | 83.15 | 73.34 | 65.48 | 61.23 | 72.78 |
| CT-Navigator | 67.00 | 81.00 | 52.50 | 40.90 | 60.35 | 71.10 | 89.40 | 58.60 | 56.40 | 68.88 | 79.31 | 53.77 | 52.25 | 33.83 | 59.88 |
Table 3. Comparison results on Merlin, CT-RATE, and DeepTumorVQA. Results are reported as accuracy (%). Char., Recog., Loc., Meas., Vis.R. and Med.R. denote characterization, recognition, localization, measurement, visual and medical reasoning.
Ablation Study
Effect of Training Stages. We conduct ablation study on our training stages. As shown in Table 4, we compare the base model (Qwen3.5-9B), agentic SFT, and subsequent RL training outcomes. On CTNavi-Bench, agentic SFT increases overall accuracy from 46.06% to 66.39%, and RL further improves it to 79.50%. The same progression can be observed across the three external benchmarks, where RL improves over agentic SFT by 4.97%, 5.23%, and 6.28% on Merlin, CT-RATE, and DeepTumorVQA, respectively. The final model outperforms the base model by 33.44% on CTNavi-Bench and 20.95%–24.22% across the external benchmarks. These consistent gains demonstrate the model’s effectiveness in CT interpretation and its ability to generalize across datasets.
| Base | SFT | RL | Ours | Merlin | RATE | DeepT |
| ✓ | 46.06 | 36.13 | 47.18 | 38.93 | ||
| ✓ | ✓ | 66.39 | 55.38 | 63.65 | 53.60 | |
| ✓ | ✓ | ✓ | 79.50 | 60.35 | 68.88 | 59.88 |
| Gains (Δ) | +33.44↑ | +24.22↑ | +21.70↑ | +20.95↑ |
Table 4. Ablation study of training stages. Gains denote the improvement of the final RL model over base model.
Tool Configuration and Invocation Patterns. We further investigate how different tool configurations affect CT understanding performance and how tool usage varies across question types. Given the substantial computational cost of RL, we conduct tool configuration ablations at the agentic SFT stage. Table 5 compares variants whose training trajectories consist of different tool combinations. Adding
| Percep. | Retri. | Mea. | Ours | Merlin | RATE | DeepT | Avg |
| ✓ | 65.01 | 55.35 | 61.10 | 43.70 | 56.29 | ||
| ✓ | ✓ | 64.29 | 55.78 | 64.55 | 46.75 | 57.84 | |
| ✓ | ✓ | ✓ | 66.39 | 55.38 | 63.65 | 53.60 | 59.75 |
Table 5. Tool ablation results of agentic SFT. Percep., Retri., and Mea. denote the visual perception, retrieval and measurement tools, respectively.
retrieval to perception tools improves mean accuracy from 56.29% to 57.84%, and further adding measurement tools raises it to 59.75%. The largest gain occurs on DeepTumorVQA, where accuracy increases from 43.70% with perception tools alone to 53.60% with the full toolkit. Perception with retrieval performs best on Merlin and CT-RATE. This may reflect differences in task composition, as DeepTumorVQA contains many organ measurement questions that benefit from measurement tools. Across all four benchmarks, the full toolkit achieves the highest mean accuracy.
Figure 4 further analyzes question-level tool invocation rates on CTNavi-Bench. Notably, slice selection, window adjustment, and region magnification are frequently invoked across question categories. These tools let the model actively inspect CT images at different locations, scales, and display settings, forming the foundation of progressive visual perception. Specialized tools show more selective usage. Retrieval is most frequent for localization at 19.14%, whereas measurement and segmentation are most frequent for quantification at 50.09% and 14.46%, respectively. These patterns reflect task-dependent evidence acquisition.
Figure 4. Tool invocation rate across tasks on CTNavi-Bench.
Conclusion
In this paper, we introduced CT-Navigator, an agentic framework that adapts generalist MLLMs to 3D CT interpretation through hierarchical visual exploration and radi-
ology tool invocation. To develop these capabilities, we curated 8,904 V-CoT trajectories and adopted a two-stage training strategy combining cold-start SFT with RL. Data selection and dynamic rollout sampling prioritize informative learning signals for policy improvement. Experiments on our proposed CTNavi-Bench and three external benchmarks demonstrate superior performance and generalization abilities of CT-Navigator. In the future, we will scale up the training data to further improve the performance.
LLM Usage Statement
In this work, we used ChatGPT (GPT-5.6-Sol) and OpenAI Codex to assist with synthetic data generation, method implementation, and manuscript preparation. The conceptual framework, scientific decisions, and interpretation of experimental results were determined by the authors. We reviewed all AI-assisted outputs and take full responsibility for the final submission, including its text, code, scientific claims, citation accuracy, experimental results, and reproducibility.
References
- [1]Jean-Baptiste Alayrac, Jeff Donahue, Pauline Luc, Antoine Miech, Iain Barr, Yana Hasson, Karel Lenc, Arthur Mensch, Katherine Millican, Malcolm Reynolds, et al. Flamingo: a visual language model for few-shot learning. Advances in neural information processing systems, 35:23716–23736, 2022. 2arxiv.org/abs/2204.14198
- [2]Fan Bai, Yuxin Du, Tiejun Huang, Max Q-H Meng, and Bo Zhao. M3d: Advancing 3d medical image analysis with multi-modal large language models. arXiv preprint arXiv:2404.00578, 2024. 2, 3, 7arxiv.org/abs/2404.00578
- [3]Michael Baumgartner, Paul F Jäger, Fabian Isensee, and Klaus H Maier-Hein. nndetection: a self-configuring method for medical object detection. In International conference on medical image computing and computer-assisted intervention, pages 530–539. Springer, 2021. 5DOI
- [4]Louis Blankemeier, Ashwin Kumar, Joseph Paul Cohen, Jiaming Liu, Longchao Liu, Dave Van Veen, Syed Jamal Safdar Gardez, Hongkun Yu, Magdalini Paschali, Zhihong Chen, et al. Merlin: a computed tomography vision-language foundation model and dataset. Nature, 652(8112):1318–1328, 2026. 7DOI
- [5]RJM Bruls and RM Kwee. Workload for radiologists during on-call hours: dramatic increase in the past 15 years. Insights into imaging, 11(1):121, 2020. 2DOI
- [6]question answering. arXiv preprint arXiv:2505.18915, 2025. 3, 7arxiv.org/abs/2505.18915
- [7]Yong Xien Chng, Tao Hu, Wenwen Tong, Xueheng Li, Jian-dong Chen, Haojia Yu, Jiefan Lu, Hewei Guo, Hanming Deng, Chengjun Xie, Gao Huang, and Lewlei Lu. Sense-research: Empowering vision-language models with high-resolution agentic search-reasoning via reinforcement learning. In Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR), pages 26508–26517, 2026. 5
- [8]Trafton Drew, Karla Evans, Melissa L-H Võ, Francine L Jacobson, and Jeremy M Wolfe. Informatics in radiology: what can you see in a single glance and how might this guide visual search in medical images? Radiographics, 33(1):263–274, 2013. 1DOI
- [9]Chengyu Fang, Heng Guo, Zheng Jiang, Chunning He, Xiu Li, and Minfeng Xu. Photon: Speedup volume understanding with efficient multimodal large language models. In The Fourteenth International Conference on Learning Representations, 2026. 3, 7arxiv.org/abs/2603.25155
- [10]Yibing Fu, Yunpeng Zhao, Zhitao Zeng, Cheng Chen, and Yueming Jin. Unleashing the power of image-tabular self-supervised learning via breaking cross-tabular barriers. In Proceedings of the AAAI Conference on Artificial Intelligence, pages 4049–4057, 2026. 2
- [11]Xiaotang Gai, Jiaxiang Liu, Yichen Li, Zijie Meng, Jian Wu, and Zuozhuo Liu. 3d-rad: A comprehensive 3d radiology med-vqa dataset with multi-temporal analysis and diverse diagnostic tasks. Advances in Neural Information Processing Systems, 38, 2026. 3arxiv.org/abs/2506.11147
- [12]Ibrahim Ethem Hammami, Sezgin Er, Chenyu Wang, Furkan Almas, Ayse Gulnihan Simsek, Seval Nil Ersigun, Irem Dogan, Omer Faruk Durugol, Benjamin Hou, Suprosanna Shit, et al. Generalist foundation models from a multimodal dataset for 3d computed tomography. Nature Biomedical Engineering, pages 1–19, 2026. 7
- [13]Constantin Ulrich Harsy, Tassilo Wald, Karol Gotkowski, Yannick Kirchhoff, Marcel Knopp, Maximilian Rokuss, Elisa Stegmeier, Philipp Schader, Dasha Trofimova, Raphael Stock, et al. nnfoundation: 3d foundation models for radiology. arXiv preprint arXiv:2609.26924, 2026. 5arxiv.org/abs/2609.26924
- [14]Micelle J Haydel, Charles A Preston, Trevor J Mills, Samuel Luber, Erick Blaudeau, and Peter MC DeBlieux. Indications for computed tomography in patients with minor head injury. New England Journal of Medicine, 343(2):100–105, 2000. 1pubmed.ncbi.nlm.nih.gov/10891517
- [15]Yufan He, Pengfei Guo, Yucheng Tang, Andriy Myronenko, Vishwesh Nath, Ziyue Xu, Dong Yang, Can Zhao, Benjamin Simon, Mason Belue, et al. Vista3d: A unified segmentation foundation model for 3d medical imaging. In 2025 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR), pages 20863–20873. IEEE, 2025. 5arxiv.org/abs/2406.05285
- [16]Jack Hong, Chenxiao Zhao, ChengLin Zhu, Weiheng Lu, Guohai Xu, and XingYu. Deepesv2: Toward agentic multimodal model. In The Fourteenth International Conference on Learning Representations, 2026. 5arxiv.org/abs/2511.05271
- [17]Songtao Jiang, Yuan Wang, Sibo Song, Tianxiang Hu, Chenyi Zhou, Bin Pu, Yan Zhang, Zhibo Yang, Yang Feng, Joey Tianyi Zhou, et al. Hulu-med: A transparent generalist model towards holistic medical vision-language understanding. arXiv preprint arXiv:2510.08668, 2025. 2, 7arxiv.org/abs/2510.08668
- [18]Patrick Lewis, Ethan Perez, Aleksandra Piktus, Fabio Petroni, Vladimir Karpukhin, Naman Goyal, Heinrich Küttler, Mike Lewis, Wen-tau Yih, Tim Rocktäschel, et al. Retrieval-augmented generation for knowledge-intensive nlp tasks. Advances in neural information processing systems, 33:9459–9474, 2020. 5arxiv.org/abs/2005.11401
- [19]Chunyuan Li, Cliff Wong, Sheng Zhang, Naoto Usuyama, Haotian Liu, Jianwei Yang, Tristan Naumann, Hoifung Poon, and Jianfeng Gao. Llava-med: Training a large language-and-vision assistant for biomedicine in one day. Advances in neural information processing systems, 36:28541–28564, 2023. 2arxiv.org/abs/2306.00890
- [20]Tianwei Lin, Wenqiao Zhang, Sijing Li, Yuqian Yuan, Binhe Yu, Haoyuan Li, Wanggui He, Hao Jiang, Mengze Li, Xiaoahui Song, et al. Healthgpt: A medical large vision-language model for unifying comprehension and generation via heterogeneous knowledge adaptation. arXiv preprint arXiv:2502.09838, 2025. 7arxiv.org/abs/2502.09838
- [21]Tianwei Lin, Zhenwei Qiu, Wenqiao Zhang, Jiang Liu, Yihan Xie, Mingjian Gao, Zhenxuan Fan, Zhaocheng Li, Sijing Li, Zhongle Xie, Peng LU, Yueting Zhuang, Ling Zhang, Beng Chin Ooi, and Yingda Xia. OmniCT: Towards a unified slice-volume LVLM for comprehensive CT analysis. In The Fourteenth International Conference on Learning Representations, 2026. 3, 7arxiv.org/abs/2602.16110
- [22]Weixiong Lin, Ziheng Zhao, Xiaoman Zhang, Chaoyi Wu, Ya Zhang, Yanfeng Wang, and Weidi Xie. Pmc-clip: Contrastive language-image pre-training using biomedical documents. In international conference on medical image computing and computer-assisted intervention, pages 525–536. Springer, 2023. 2arxiv.org/abs/2303.07240
- [23]Haotian Liu, Chunyuan Li, Qingyang Wu, and Yong Jae Lee. Visual instruction tuning. Advances in neural information processing systems, 36:34892–34916, 2023. 2
- [24]Ohad Oren, Bernard J Gersh, and Deepak L Bhatt. Artificial intelligence in medical imaging: switching from radiographic pathological data to clinically meaningful endpoints. The Lancet Digital Health, 2(9):e486–e488, 2020. 2DOI
- [25]Dré Peeters, Bogdan Obreja, Noa Antonissen, Zaigham Saghir, Ugo Pastorino, Mario Silva, Geertruida H De Bock, Hester Gietema, Fergus Gleeson, Marjolein A Heuvelmans, et al. Benchmarking of ai and radiologists for indeterminate lung nodule malignancy risk estimation at screening ct: The luna25 challenge. Radiology: Artificial Intelligence, 8(5):e260179, 2026. 5DOI
- [26]Guanyi Qin, Xiaozhen Wang, Zhu Zhuo, Chang Han Low, Yuancan Xiao, Yibing Fu, Haofeng Liu, Kai Wang, Chunjiang Li, and Yueming Jin. Surgo-r1: Benchmarking and modeling contextual reasoning for operative zone in surgical video. arXiv preprint arXiv:2602.21706, 2026. 5arxiv.org/abs/2602.21706
- [27]Guanyi Qin, Junjie Zhang, Chunming He, Yibing Fu, Jie Liang, Tianhe Wu, and Lei Zhang. Tool-iqa: Augmenting image quality assessment with simple tools. arXiv preprint arXiv:2606.16082, 2026. 5arxiv.org/abs/2606.16082
- [28]Qwen Team. Qwen3.5: Towards native multimodal agents, 2026. 4, 6
- [29]Qwen Team. Qwen3.6-27B: Flagship-level coding in a 27B dense model, 2026. 7
- [30]Alec Radford, Jong Wook Kim, Chris Hallacy, Aditya Ramesh, Gabriel Goh, Sandhini Agarwal, Girish Sastry, Amanda Askell, Pamela Mishkin, Jack Clark, et al. Learning transferable visual models from natural language supervision. In International conference on machine learning, pages 8748–8763. PMLR, 2021. 2arxiv.org/abs/2103.00020
- [31]Arnaud Arindra Adiyoso Setio, Alberto Traverso, Thomas De Bel, Moira SN Berens, Cas Van Den Bogaard, Piergiorgio Cerello, Hao Chen, Qi Dou, Maria Evelina Fantacci, Bram Geurts, et al. Validation, comparison, and combination of algorithms for automatic detection of pulmonary nodules in computed tomography images: the luna16 challenge. Medical image analysis, 42:1–13, 2017. 5
- [32]Qwen Team. Qwen3.5-5-omn technical report. arXiv preprint arXiv:2604.15804, 2026. 7arxiv.org/abs/2604.15804
- [33]Eric J Topol. High-performance medicine: the convergence of human and artificial intelligence. Nature medicine, 25(1):44–56, 2019. 2DOI
- [34]Tao Tu, Shekoofeh Azizi, Danny Driess, Mike Schaeker-mann, Mohamed Amin, Pi-Chuan Chang, Andrew Carroll, Charles Lau, Ryutaro Tanno, Ira Ktena, et al. Towards generalist biomedical ai. Nej Ai, 1(3):Aloa2300138, 2024. 2DOI
- [35]Avivah J Wang, Fakrul Islam Tushar, Michael R Harowicz, Betty C Tong, Kyle J Lafata, Tina D Tailor, and Joseph Y Lo. The duke lung cancer screening (dlcs) dataset: a reference dataset of annotated low-dose screening thoracic ct. Radiology: Artificial Intelligence, 7(4):e240248, 2025. 5DOI
- [36]Xiaosong Wang, Yifan Peng, Le Lu, Zhiyong Lu, and Ronald M Summers. Tienet: Text-image embedding network for common thorax disease classification and reporting in chest x-rays. In 2018 IEEE/CVF Conference on Computer Vision and Pattern Recognition, pages 9049–9058. IEEE, 2018. 2arxiv.org/abs/1801.04334
- [37]Ziyue Wang, Linghan Cai, Chang Han Low, Haofeng Liu, Junde Wu, Jingyu Wang, Rui Wang, Lei Song, Jiang Bian, Jingjing Fu, et al. 3dmedagent: Unified perception-to-understanding for 3d medical analysis. arXiv preprint arXiv:2602.18064, 2026. 7arxiv.org/abs/2602.18064
- [38]Ziyue Wang, Junde Wu, Linghan Cai, Chang Low, Xihong Yang, Qixuan Li, and Yueming Jin. Medagent-pro: Towards evidence-based multi-modal medical diagnosis via reasoning agentic workflow. In International Conference on Learning Representations, pages 114360–114389, 2026. 2
- [39]Chaoyi Wu, Xiaoman Zhang, Ya Zhang, Hui Hui, Yanfeng Wang, and Weidi Xie. Towards generalist foundation model for radiology by leveraging web-scale 2d&3d medical data. Nature Communications, 16(1):7866, 2025. 2, 3, 7DOI
- [40]Weiwen Xu, Hou Pong Chan, Long Li, Mahani Aljunied, Ruifeng Yuan, Jianyu Wang, Chenghao Xiao, Guizhen Chen, Chaoqun Liu, Zhaodonghui Li, et al. Lingshu: Generalist foundation model for unified multimodal medical understanding and reasoning. IEEE Transactions on Pattern Analysis and Machine Intelligence, 2026. 2, 7
- [41]Ke Yan, Xiaosong Wang, Le Lu, and Ronald M Summers. Deeplesion: automated mining of large-scale lesion annotations and universal lesion detection with deep learning. Journal of medical imaging, 5(3):036501–036501, 2018.DOI
- [42]An Yang, Anfeng Li, Baosong Yang, Beichen Zhang, Binyuan Hui, Bo Zheng, Bowen Yu, Chang Gao, Chengeng Huang, Chenxu Lv, et al. Qwen3 technical report. arXiv preprint arXiv:2505.09388, 2025.arxiv.org/abs/2505.09388
- [43]Shunyu Yao, Jeffrey Zhao, Dian Yu, Nan Du, Izhak Shafran, Karthik Narasimhan, and Yuan Cao. React: Synergizing reasoning and acting in language models. arXiv preprint arXiv:2210.03629, 2022.arxiv.org/abs/2210.03629
- [44]Qiying Yu, Zheng Zhang, Ruofei Zhu, Yufeng Yuan, Xiaochen Zuo, Yu Yue, Weinan Dai, Tiantian Fan, Gaohong Liu, Lingjun Liu, Xin Liu, Haibin Lin, Zhiqi Lin, Bole Ma, Guangming Sheng, Yuxuan Tong, Chi Zhang, Mofan Zhang, Wang Zhang, Hang Zhu, Jinhua Zhu, Jiaze Chen, Jiangjie Chen, Chengyi Wang, Hongli Yu, Yuxuan Song, Xiangpeng Wei, Hao Zhou, Jingjing Liu, Wei-Ying Ma, Ya-Qin Zhang, Lin Yan, Mu Qiao, Yonghui Wu, and Mingxuan Wang. Dapo: An open-source llm reinforcement learning system at scale, 2025.arxiv.org/abs/2503.14476
- [45]Sheng Zhang, Yanbo Xu, Naoto Usuyama, Hanwen Xu, Jaspreet Bagga, Robert Tinn, Sam Preston, Rajesh Rao, Mu Wei, Naveen Valluri, et al. Biomedclip: a multimodal biomedical foundation model pretrained from fifteen million scientific image-text pairs. arXiv preprint arXiv:2303.00915, 2023.arxiv.org/abs/2303.00915
- [46]Xiaoman Zhang, Chaoyi Wu, Ziheng Zhao, Jiayu Lei, Weiwei Tian, Ya Zhang, Weidi Xie, and Yanfeng Wang. Development of a large-scale grounded vision language dataset for chest ct analysis. Scientific Data, 12(1):1636, 2025.DOI
- [47]Yanzhao Zhang, Mingxin Li, Dingkun Long, Xin Zhang, Huan Lin, Baosong Yang, Pengjun Xie, An Yang, Dayiheng Liu, Junyang Lin, et al. Qwen3 embedding: Advancing text embedding and reranking through foundation models. arXiv preprint arXiv:2506.05176, 2025.arxiv.org/abs/2506.05176
- [48]Chujie Zheng, Shixuan Liu, Mingze Li, Xiong-Hui Chen, Bowen Yu, Chang Gao, Kai Dang, Yuqiong Liu, Rui Men, An Yang, Jingren Zhou, and Junyang Lin. Group sequence policy optimization, 2025.arxiv.org/abs/2507.18071
- [49]Jinguo Zhu, Weiyun Wang, Zhe Chen, Zhaoyang Liu, Shenglong Ye, Lixin Gu, Hao Tian, Yuchen Duan, Weijie Su, Jie Shao, et al. Internvl3: Exploring advanced training and test-time recipes for open-source multimodal models. arXiv preprint arXiv:2504.10479, 2025.arxiv.org/abs/2504.10479