Do Not Let the Prior Heal the Anomaly: Selective Anchoring for Detection from Incomplete Measurements

Abstract

Generative priors can recover anatomical detail from incomplete medical measurements, but may erase the very lesions that imaging aims to detect, even when the measurements contain evidence of them. We introduce selective anchoring that protects reliably measured image components from prior-driven changes, while allowing expressive generative models to reconstruct unresolved structure. Acquisition uncertainty in the protected components is either added deterministically to the downstream test or carried by the ensemble through stochastic perturbations of the readings. We implement this principle as a wrapper for pretrained diffusion and flow samplers and as AnchoredFM, a fast constrained flow model. Under a linear-Gaussian measurement model, the protected coefficients are unbiased in expectation and achieve nominal interval coverage across repeated acquisitions, independently of the learned prior. Across sparse-view CT, accelerated brain MRI, and photoacoustic tomography, selective anchoring improves lesion contrast preservation and uncertainty reliability, and can reduce reconstruction error within lesions. For tumor detection in accelerated MRI, with a healthy reference estimated from the measurements alone, deterministic anchoring raises mean AUROC across eight samplers from 78.4% to 84.6% and lesion sensitivity at 0.25 false-positive marks per slice from 38.8% to 47.5%, with gains in all four predefined tumor-size groups. At thresholds frozen on healthy validation data, mean sensitivity rises from 20.2% to 44.1% (37.6% with stochastic anchoring). These findings show how expressive generative priors can reconstruct unresolved anatomy without healing away the abnormalities that the measurements support.

Figure 1. Selective anchoring detects a tumor that unanchored conditional FM misses (left) and removes a false alarm (right) on brain MRI from 64 k-space lines. Anchoring preserves the lesion and its uncertainty better. Left: the unanchored score stays below its validation threshold at the tumor, although the tumor is visible in the ensemble mean. With anchoring the same region exceeds the detection score threshold. Right: the unanchored samples agree more closely than the measurement noise warrants, so a small deviation appears statistically significant. Columns: truth, ensemble mean, standard deviation (SD, % of median brain intensity), and Student’s t-test score from Eq. (9) over its decision threshold. Dashed: expert tumor boundary; solid: score of one; insets enlarge the boxed region.

Generative priors can recover anatomical detail from incomplete medical measurements, but may erase the very lesions that imaging aims to detect, even when the measurements contain evidence of them. We introduce selective anchoring that protects reliably measured image components from prior-driven changes, while allowing expressive generative models to reconstruct unresolved structure. Acquisition uncertainty in the protected components is either added deterministically to the downstream test or carried by the ensemble through stochastic perturbations of the readings. We implement this principle as a wrapper for pretrained diffusion and flow samplers and as AnchoredFM, a fast constrained flow model. Under a linear-Gaussian measurement model, the protected coefficients are unbiased in expectation and achieve nominal interval coverage across repeated acquisitions, independently of the learned prior.

Across sparse-view CT, accelerated brain MRI, and photoacoustic tomography, selective anchoring improves lesion contrast preservation and uncertainty reliability, and can reduce reconstruction error within lesions. For tumor detection in accelerated MRI, with a healthy reference estimated from the measurements alone, deterministic anchoring raises mean AUROC across eight samplers from 78.4% to 84.6% and lesion sensitivity at 0.25 false-positive marks per slice from 38.8% to 47.5%, with gains in all four predefined tumor-size groups. At thresholds frozen on healthy validation data, mean sensitivity rises from 20.2% to 44.1% (37.6% with stochastic anchoring). These findings show how expressive generative priors can reconstruct unresolved anatomy without healing away the abnormalities that the measurements support.

Introduction

Sparse-view CT, accelerated MRI, and photoacoustic tomography use fewer measurements to reduce radiation exposure, scan time, or detector requirements in medical imaging. With incomplete data, direct inversion can amplify noise or produce streaking and aliasing. Learned generative priors help reconstruct anatomical structures that the measurements cannot fully determine [1, 2, 3]. However, when these priors are trained predominantly on normal images, they may favor healthy-looking anatomy and weaken or remove lesions, even when the acquired measurements contain evidence of them [4].

A common anomaly-detection approach compares a patient’s reconstructed ensemble mean, xˉ\bar{x}, obtained from incomplete measurements yy, with a healthy reference, rr, representing the same anatomy without pathology [5, 6, 7]. The subtraction residual is

Δx=xˉ−r.(1)\Delta x = \bar{x} - r. \tag*{(1)}

If reconstruction weakens the contrast of a lesion, the difference between the reconstructed image and the healthy reference may be too small to detect it. A second problem arises when the reconstruction underestimates its uncertainty. In this case, differences in healthy tissue may appear statistically significant and lead to false alarms.

Incomplete measurements do not constrain every part of an image equally. Some image components can be estimated reliably from the observations, while others are weakly measured or entirely unobserved. Existing generative methods were designed for image quality, not for anomaly preservation and detection. Samplers that guide or condition on the measurements [1, 3, 8] let the prior alter reliably measured components, which can weaken an anomaly and cause missed lesions. Samplers that enforce the measurements exactly [9, 10, 11] give every sample the same measured values, so a downstream test reads their agreement as certainty although the readings are noisy, causing false alarms. A reconstruction meant for detection should therefore take both the evidence and its noise from the measurements, and leave to the prior only what they do not resolve.

We introduce selective anchoring to preserve reliably measured image components while allowing the generative model to reconstruct the remainder. The protected components correspond to image-space singular-vector directions of the known imaging operator. We select directions whose measurement uncertainty is small relative to normal-image variability and constrain their coefficients to measurement-derived values. Weakly measured directions and the measurement null space remain available for generative completion. We consider two ways of accounting for measurement uncertainty. Deterministic anchoring fixes the protected coefficients at their measurement-derived values and adds their known variance analytically to downstream detection tests. Stochastic anchoring instead assigns each reconstruction sample an independently perturbed target, allowing the ensemble to represent acquisition uncertainty and potentially propagate its effects into the generated components. For a known linear measurement operator AA with additive Gaussian noise, y=Ax+ϵy = Ax + \epsilon and ϵ∼N(0,σ2I)\epsilon\sim\mathcal{N}(0,\sigma^2 I), the protected coefficient estimates are unbiased over repeated acquisitions, and their analytic intervals achieve nominal coverage independently of the learned model for the remaining components (Proposition 1). We implement selective anchoring as a training-free wrapper for pretrained generative samplers and as AnchoredFM, a flow-matching model that evolves only the unconstrained components [12].

We evaluate selective anchoring on inserted CT lesions, real brain tumors under simulated accelerated MRI, and photoacoustic breast phantoms. Across these tests, anchoring better preserves measurement-supported lesion contrast, improves uncertainty calibration in the protected directions, and often reduces reconstruction error within lesions (Table 1 and § 5.3). For primary MRI detection, we construct a healthy reference rr by checkerboard inpainting from the measurements and fit thresholds using healthy validation slices. Across eight matched sampler pairs, anchoring raises mean AUROC from 78.4% to 84.6% and lesion sensitivity at 0.25 false-positive marks per slice from 38.8% to 47.5% (Table 1, Table 2 and Table S16). At validation-frozen thresholds, mean sensitivity rises from 20.2% to 44.1%. An additional oracle test provides a controlled reference comparison (§ 18). At low sampling budgets, Anchored Flow Matching (AnchoredFM) achieves competitive lesion preservation and uncertainty performance while remaining substantially faster than full-budget generative samplers.

SamplerRMSEContrast errorSens.valSens. @0.25FAval
cFM13.911.123.540.84.9
+ anchoring12.28.446.849.03.4
EDM11.79.441.345.63.5
+ anchoring10.87.145.147.73.4
DPS11.07.215.834.62.6
+ anchoring11.07.740.045.13.1
DDGM10.97.622.641.73.5
+ anchoring10.87.644.046.83.4
DDRM11.69.315.738.12.4
+ anchoring11.27.843.047.33.2
DDNM11.17.02.329.00.6
+ anchoring11.06.643.547.93.4
DiffPIR11.07.728.941.75.0
+ anchoring10.66.345.048.63.4
P-DDIM11.08.311.638.73.4
+ anchoring10.87.345.048.03.3
AnchoredFM12.39.346.449.63.4
Reference-free KLIP controlAUROCDet5_5FAval
KLIP83.755.16.7
+ deterministic anchoring93.771.24.9

Table 1. Brain MRI, 256 grid and 64 lines: 661 tumor and 701 healthy slices from 60 patients. Contrast error is absolute departure from full recovery. Reconstruction and detection metrics are in %, with RMSE relative to median intensity. Subtraction detection uses shared checkerboard references over ten seeds. The reference-free KLIP panel reports AUROC, retrospective Det5_5 and validation-frozen FA (Sec. S7.4). Bold/italic mark better/worse reconstruction (Holm-adjusted); detection columns are unmarked. AnchoredFM is compared with cFM.

Tumor sizeLesionsSlicesPatients0.25 false positives per slice: base0.25 false positives per slice: anchored0.25 false positives per slice: difference1 false positive per slice: base1 false positive per slice: anchored1 false positive per slice: difference
11–23 mm217173606.910.1+3.2 [+1.0, +5.5]20.529.2+8.7 [+5.6, +11.4]
23–34 mm2141735930.143.0+13.0 [+9.5, +16.5]55.363.8+8.4 [+5.8, +11.4]
34–45 mm1951675655.767.3+11.6 [+8.3, +15.2]74.880.2+5.5 [+3.0, +8.4]
≥45 mm1651485071.979.3+7.3 [+4.3, +10.4]86.187.4+1.3 [-0.1, +2.9]
All7916616038.847.5+8.8 [+6.9, +10.6]57.063.3+6.3 [+4.9, +7.7]

Table 2. Lesion sensitivity (%) by tumor size in brain MRI at 64 of 256 lines, using the fixed checkerboard-inpainting reference averaged over ten seeds on parts 1–3 (791 lesions in 661 tumor slices and 701 tumor-free slices of 60 patients). Values average the eight matched sampler pairs in Table 1. Size is the predefined equivalent diameter of each tumor component in the slice. For each sampler and operating point, one score threshold is set over all 1362 evaluated slices and held fixed across size groups. Differences are anchored minus base in percentage points, with 95% intervals from paired patient-and-reference-seed bootstrap draws.

LinesTreatmentAUROCpAUC5_5Det5_5Sens.val_{\mathrm{val}}FAval_{\mathrm{val}}[email protected]
32base67.15.911.48.02.921.9
32deterministic79.229.236.829.52.339.4
32stochastic77.218.728.523.83.436.3
64base78.414.826.620.23.238.8
64deterministic84.636.449.044.13.347.5
64stochastic84.132.343.037.63.444.5

Table S16. Matched MRI treatment means (%) at 32/64 lines over ten reference seeds. Healthy-part-0 thresholds are frozen for testing. P-DDIM uses η0=0\eta_0 = 0 in all treatments. AnchoredFM is excluded from these eight-sampler means.

Related work

Image-based anomaly detection. Image-based anomaly detection often compares a test image with a pseudo-healthy reference learned from normal anatomy [5, 13]. Diffusion-based methods generate these references through noising and denoising or guided reconstruction [6, 14, 15, 16]. Other approaches detect simulated defects, as in DRAEM [17], or use pretrained features, as in PatchCore and Dinomaly [18, 19]. These methods generally assume that the test image is available, whereas tomographic anomaly detection requires reconstructing it from incomplete measurements.

Pathology preservation in tomography. The reconstruction step introduces a separate failure mode for downstream detection, as learned priors can suppress clinically relevant features while producing plausible images. Bhadra et al. [4] analyzed hallucinations by distinguishing measurement-supported and null-space components, while accelerated MRI studies have shown that rare pathology may be missed despite favorable reconstruction metrics [20, 21, 22]. To address missed pathology, Morshuis et al. [23] generated semantically diverse, measurement-consistent MRI reconstructions. Other studies examine distribution shifts from incomplete measurements [24, 25, 26], including KLIP [27], which detects localized abnormalities by comparing diffusion prior and posterior distributions. These approaches reveal reconstruction failures or identify abnormalities from the measurements. Our focus is on retaining measurement-supported lesion contrast and its associated uncertainty in the reconstruction samples used for downstream detection.

Measurement consistency and uncertainty. Preserving measured information depends on how generative reconstruction incorporates the observations. Diffusion and flow priors use learned conditioning or measurement-guided sampling [1, 3, 8]. Several methods instead fix the measured components, within each sampling step (DDNM [9]), as a final lock (Measured-Subspace Consistency [10]), or by confining a flow to the null space (NullFlow [11]). These hold every measured direction, whereas truncated-SVD learning [28] holds only those with large singular values. Fixing the measured components limits the prior, but giving every sample the same values removes their ensemble variation even though the readings are noisy. Other work handles noise during sampling [29, 30], by calibration on held-out data [31, 32], or with perturbed observations in Kalman and Gaussian posterior sampling [33, 34]. Selective anchoring holds only the directions whose noise is small relative to normal-image variability and keeps their acquisition variance, analytically in the test or through perturbed readings. Unlike DDRM and Posterior-DDIM [2, 35], which weigh prior against measurement in each singular direction, we remove the prior from the held directions, so their coefficients are unbiased with nominal coverage for each fixed image, not only on average over the prior; both are among our baselines (Table 1).

Anomaly-preserving reconstruction

We seek to reconstruct an image while retaining lesion evidence supported by incomplete measurements. Write x=b+ℓx = b + \ell, with healthy anatomy bb and lesion signal ℓ\ell, and assume

y=Ax+ε,ε∼N(0,σ2Im),(2)y = Ax + \varepsilon,\qquad\varepsilon\sim\mathcal{N}(0,\sigma^2 I_m), \tag*{(2)}

where A∈Rm×dA \in\mathbb{R}^{m \times d} and σ>0\sigma> 0 are known. A prior trained on normal images helps infer anatomy that the measurements do not resolve. Its preference for normal anatomy can also attenuate lesions, even in components measured reliably. Our aim is to protect those components while using the prior to reconstruct the remainder.

The reconstructor returns K≥2K \ge2 samples xjx_j, whose mean xˉ=K−1∑jxj\bar{x} = K^{-1}\sum_j x_j and spread describe reconstructed evidence and its uncertainty. Their distribution need not equal the true posterior. For downstream subtraction against a healthy reference rr estimating bb,

xˉ−r=ℓ+(xˉ−x)−(r−b).\bar{x} - r = \ell+ (\bar{x} - x) - (r - b).

This separates reconstruction error from reference error. Anchoring addresses the former; the experiments compare reconstructors using a shared reference for each image (§ 5.4).

Selective anchoring

Selecting what to preserve. A component can be protected directly when its measurement is sufficiently precise. For the compact SVD A=∑isiuiviTA = \sum_i s_i u_i v_i^\mathsf{T}, si>0s_i > 0, the coefficient zi=viTxz_i = v_i^\mathsf{T}x has reading

y~i=uiTy/si=zi+ei,ei∼N(0,ni),ni=σ2/si2.(3)\tilde{y}_i = u_i^\mathsf{T} y/s_i = z_i + e_i,\qquad e_i \sim\mathcal{N}(0,n_i),\qquad n_i = \sigma^2/s_i^2. \tag*{(3)}

Small singular values amplify measurement noise, so preserving every measured direction would also retain unreliable components. To select reliable readings, we compare their noise with normal-image variability. Fit a stationary Gaussian surrogate N(μ,C)\mathcal{N}(\mu,C) to normal training images and define

ri=viTCvini,H={i:ri>κ},κ≥1.(4)r_i = \frac{v_i^\mathsf{T} C v_i}{n_i},\qquad\mathcal{H} = \{i:r_i > \kappa\},\qquad\kappa\ge1. \tag*{(4)}

Large rir_i identifies readings precise relative to normal variability. In a scalar Gaussian model, prior shrinkage attenuates departures from the normal mean by ri/(1+ri)r_i/(1+r_i). Using the reading directly avoids this attenuation at a small relative variance cost when rir_i is large (see Sec. S1).

Let VHV_{\mathcal{H}} contain the selected right singular vectors, PH=VHVHT\mathcal{P}_{\mathcal{H}} = V_{\mathcal{H}}V_{\mathcal{H}}^\mathsf{T}, and Π=I−PH\Pi= I - \mathcal{P}_{\mathcal{H}}. The lift assembles the held coefficients into an image component:

lift⁡(y)=∑i∈Hy~ivi.(5)\operatorname{lift}(y) = \sum_{i\in\mathcal{H}} \tilde{y}_i v_i. \tag*{(5)}

The model generates the free component in the range of Π\Pi, which includes weakly measured directions and the null space. An anomaly can occupy both subspaces, and direct preservation concerns its held component.

Representing measurement uncertainty. The anchoring constraint is shared by two uncertainty treatments. Deterministic anchoring sets hj=lift⁡(y)h_j = \operatorname{lift}(y) for every sample and adds the known held-direction variance to downstream tests. Stochastic anchoring draws ηj∼N(0,Im)\eta_j \sim\mathcal{N}(0,I_m) independently across samples and sets hj=lift⁡(y+σηj)h_j = \operatorname{lift}(y + \sigma\eta_j), so the ensemble carries acquisition uncertainty. In either case, sample jj keeps the same target hjh_j throughout generation. We enforce PHxj=hjP_H x_j = h_j, equivalently xj=hj+Πxjx_j = h_j + \Pi x_j, so the held component equals its sampled target exactly. Under stochastic anchoring, held coefficient ii conditional on yy follows N(y~i,ni)\mathcal{N}(\tilde{y}_i,n_i); deterministic anchoring uses this same known measurement law in downstream uncertainty calculations.

Proposition 1 (Held directions). Under Eq. (2), fix the held subspace and an image x=b+ℓx = b + \ell. Averaging over acquisition noise for deterministic anchoring, and additionally over the independent target draws for stochastic anchoring, gives

E[PH(xˉ−b)]=PHℓ.\mathbb{E}\left[P_H(\bar{x}-b)\right] = P_H\ell.

For every held ii and chosen nominal coverage level γ∈(0,1)\gamma\in(0,1), the central γ\gamma-interval of N(y~i,ni)\mathcal{N}(\tilde{y}_i,n_i) covers the held coefficient ziz_i with probability γ\gamma over repeated noisy acquisitions of the same fixed image. Both guarantees hold regardless of the model used for the free part.

Pixel values combine held and generated components, so their uncertainty also depends on the generator. We therefore evaluate full-image coverage empirically; the proposition concerns analytic held-coordinate intervals under Eq. (2).

We enforce the same target through two implementations: a wrapper for pretrained samplers and AnchoredFM’s projected dynamics (Figure 2).

Selective anchoring on a 64-line MRI example

Figure 2. Selective anchoring on a 64-line MRI example (κ=1\kappa= 1). Readings of the observed k-space yy (Eq. (3)) are split and ordered by their information ratio rir_i (Eq. (4); schematic curve) into held and free sets using cutoff κ\kappa. The anchor hjh_j, deterministic or stochastic (Eq. (8)), enters the wrapper’s clean prediction (Eq. (6)), AnchoredFM’s initial state, and the output sum. Conditioning on c=x^(y)c = \hat{x}(y), computed from all readings. Optional guidance uses free readings (Sec. S1). Either implementation returns K=16K = 16 samples xj=hj+Πxjx_j = h_j + \Pi x_j; AnchoredFM samples under deterministic anchoring are shown. Right: subtraction score ∣t∣|t| (Eq. (9)) over its healthy-validation threshold, with the detected lesion outlined.

Wrapper for pretrained samplers

The wrapper acts on a sampler’s clean-image prediction D(xt,t)D(x_t,t). For a straight-path flow, D=xt+(1−t)vθ(xt,t,c)D = x_t + (1-t)v_\theta(x_t,t,c), with conditioning cc. Replace this prediction by

D′(xt,t)=hj+ΠD(xt,t).(6)D'(x_t,t) = h_j + \Pi D(x_t,t). \tag*{(6)}

This retains the predicted free component and replaces its held component with the target. The sampler uses D′D' in its update and projects the returned image to the same anchor. The network retains its conditioning, and additional data updates use the remaining measurements (Secs. S1 and S7.2).

AnchoredFM

AnchoredFM learns to evolve only the free component. For a normal training image x1x_1, construct x0=PHx1+Πξx_0 = P_Hx_1 + \Pi\xi and xt=(1−t)x0+tx1x_t = (1-t)x_0 + tx_1, with ξ∼N(0,Id)\xi\sim\mathcal{N}(0,I_d). The endpoints share their held component, so the target velocity is x1−x0=Π(x1−ξ)x_1-x_0 = \Pi(x_1-\xi). With uniform t∈[0,1]t \in[0,1], flow matching [12, 36] fits this velocity, conditioned on the surrogate MAP image x^(y)\hat{x}(y) of noisy measurements:

LAF=E[∥vθ(xt,t,x^(y))−(x1−x0)∥22].(7)\mathcal{L}_{\mathrm{AF}} = \mathbb{E}\left[\left\|v_\theta(x_t,t,\hat{x}(y))-(x_1-x_0)\right\|_2^2\right]. \tag*{(7)}

Training uses clean held coefficients. At inference, initialize with the measurement-based target and project every velocity onto the free subspace:

hj={lift⁡(y),deterministic,lift⁡(y+σηj),stochastic,x0(j)=hj+Πξj,ξj∼N(0,Id),x˙t(j)=Πvθ(xt(j),t,x^(y)).(8)\begin{aligned} h_j &= \begin{cases} \operatorname{lift}(y), & \text{deterministic},\\ \operatorname{lift}(y+\sigma\eta_j), & \text{stochastic}, \end{cases}\\ x_0^{(j)} &= h_j+\Pi\xi_j,\qquad\xi_j\sim\mathcal{N}(0,I_d),\\ \dot{x}_t^{(j)} &= \Pi v_\theta(x_t^{(j)},t,\hat{x}(y)). \tag*{(8)} \end{aligned}

Because PHΠ=0P_H\Pi= 0, the evolving state retains PHxt(j)=hjP_Hx_t^{(j)} = h_j, independently of network accuracy. We integrate with Euler steps, which require no products with AA or ATA^\mathsf{T} after computing the lift and MAP image (Sec. S1).

We assess downstream detection conditional on a shared, fixed healthy-reference estimate rr. We normalize subtraction contrast using reconstruction uncertainty, isolating the effect of anchoring for the same reference. For a candidate template wpw_p, define its sample amplitude and the treatmentspecific normalized scores by

aj(p)=⟨wp,xj−r⟩⟨wp,wp⟩,a_j(p) = \frac{\langle w_p, x_j-r\rangle}{\langle w_p,w_p\rangle},
tstoch(p)=aˉ(p)sa(p)1+1/K(9)t_{\mathrm{stoch}}(p) = \frac{\bar{a}(p)}{s_a(p)\sqrt{1+1/K}} \tag*{(9)}
tdet(p)=aˉ(p)τ2(p)+(1+1/K)sa2(p).t_{\mathrm{det}}(p) = \frac{\bar{a}(p)}{\sqrt{\tau^2(p)+(1+1/K)s_a^2(p)}}.

Here aˉ\bar{a} and sas_a are the sample mean and standard deviation, with variance denominator K−1K-1. For mixed templates, CT uses Satterthwaite degrees of freedom for tdett_{\mathrm{det}}. MRI uses K−1K-1 degrees of freedom for its core normalization and validation-frozen thresholds for practical references (§ 9.4 and § 18).

Proposition 2 (Held-template subtraction). Under Eq. (2), fix a nonzero held-only template ww with Πw=0\Pi w=0, assume the exact reference r=br=b and K≥2K\geq2, and let

τ2=∑i∈Hni⟨vi,w⟩2/⟨w,w⟩2>0.\tau^2 = \sum_{i\in\mathcal{H}} n_i\langle v_i,w\rangle^2/\langle w,w\rangle^2 > 0.

Under ℓ=0\ell=0, marginally over acquisition noise and, in part (a), the independent anchoring perturbations:

(a) For stochastic anchoring, the statistic in Eq. (9) follows tK−1t_{K-1}.

(b) For deterministic anchoring, the known-variance statistic zdet=⟨w,lift⁡(y)−r⟩/(⟨w,w⟩τ)z_{\mathrm{det}}=\langle w,\operatorname{lift}(y)-r\rangle/(\langle w,w\rangle\tau) follows N(0,1)\mathcal{N}(0,1).

Both null laws are independent of the model used for the free component.

Before evaluating the test images, we set α=5%\alpha=5\% as the target upper bound false alarm rate, and enforce this image-level bound under the null laws above using a Bonferroni threshold over all position–lesion size pairs. The exact rule is given in § 9.3.

For tests involving free template components or an estimated healthy reference, the false-alarm rate must be checked empirically. The thresholding rule, noncentral extension, mixed-template diagnostics, and proofs are given in Secs. S1, § 9.3 and § 9.4.

Experiments

Setup

Tests. For real and synthetic pathology cases, all acquisitions are simulated, and the models train on normal reconstructions. CT: LoDoPaB-CT chest slices [37] on a 256256 grid, with 6464 parallel-beam views, Gaussian noise at 1%1\% of the median central reading, and twelve inserted lesion types. Measurements use a finer-grid projector than reconstruction to avoid artificially favorable results from identical discretizations (Sec. S5.2). Brain MRI: BraTS FLAIR scans from the Medical Segmentation Decathlon [38] on a 256256 grid, with 3232 or 6464 of 256256 k-space lines and real tumors with expert masks. Training uses tumor-free slices from training patients. Photoacoustic tomography: VIC-TRE breast phantoms [39, 40] on a 256256 grid, with 6464 ring detectors and lesion-bearing/healthy twins.

Samplers. We compare conditional flow matching (cFM) [12] and EDM [41], both conditioned on x^(y)\hat{x}(y), with six zero-shot methods sharing one unconditional prior: DPS [1], Π\PiGDM [42], DDRM [2], DDNM [9], DiffPIR [43], and Posterior-DDIM [35]. Each returns K=16K=16 samples, with and without anchoring. MRI uses all eight. The 256256-grid CT test omits DPS and PGDM for cost (both run on the 128128 grid; Table S2). Photoacoustics uses cFM, DPS and DDNM. Anchored CT data steps use per-sample readings at 2σ\sqrt{2}\sigma. MRI and photoacoustics use shared readings (Sec. S7.2).

SamplerRMSE64_{64}Cov.64_{64}Det5,64_{5,64}FA64_{64}RMSE256_{256}Cov.256_{256}Det5,256_{5,256}FA256_{256}
cFM6263.924.869.34073.856.261.3
+ anchoring5781.348.34.44389.673.35.6
EDM6369.025.638.14081.055.122.5
+ anchoring5784.648.53.93886.873.84.3
DPS7571.719.01.76572.628.44.3
+ anchoring5588.949.11.54786.373.32.2
Π\PiGDM7582.747.2100.0––––
+ anchoring9189.848.16.2––––
DDRM8153.451.2100.09722.071.7100.0
+ anchoring14493.548.82.416990.673.23.3
DDNM11149.948.7100.013114.773.0100.0
+ anchoring18794.148.12.119390.372.74.0
DiffPIR6184.046.351.44492.766.91.0
+ anchoring6996.352.51.14798.274.80.7
P-DDIM5879.447.080.15181.575.095.7
+ anchoring6595.851.71.17395.973.82.2
AnchoredFM5684.650.72.83986.873.73.6
Gaussian posterior6194.648.82.54594.273.34.4
exact test––59.15.0––77.57.2
Ideal observer––71.61.9––85.62.2

Table S2. Stochastic CT128, parts 1–3: 2160 lesion and 720 healthy slices from 45 patients. Subscripts give view count. RMSE is in HU; coverage, Det5_5 and FA are in %. Marks follow Table S1; Π\PiGDM at 256 views was not run because of cost.

Protocol. We split by patient, select settings on part 0, and evaluate parts 1–3 using paired patient-bootstrap 95%95\% intervals. Base settings optimize preset-threshold F1 in CT and lesion error in MRI/photoacoustics. Anchored pairs retain these settings. CT retains its healthy-validation choice of κ\kappa when changing the uncertainty treatment, transferring it from the 128128 to the 256256 grid. MRI and photoacoustics select κ\kappa using labeled lesion error. In the primary MRI tables, + anchoring denotes deterministic anchoring. Subtraction scores include analytic projected acquisition variance. P-DDIM uses η0=0,η1=16\eta_0=0,\eta_1=16 in the primary MRI comparisons. Table significance uses bootstrap p<0.05p<0.05, Holm-adjusted across sampler pairs. Intervals quoted in the text are unadjusted.

Controls. Controls include a measurement-domain matched filter (the direct measurement control, labeled “ideal observer” in the tables), and the exact Gaussian surrogate posterior with sampled or analytic covariance. Using the same lesion templates and Bonferroni tests, the matched filter provides a detection upper bound for a known healthy reference, template, and position under the stated Gaussian model. Post-hoc rescaling fits one spread factor per base CT/MRI sampler on healthy part 0 and fixes it for testing. We also adapt KLIP [27] using the shared DPS prior, with guidance and readout selected on validation patients (§ 14.4). Acquisition, sampler, selection and control details are in Secs. S4 and § 17.

Detection and reference images. All subtraction-based methods use the same healthy-reference estimate for a test image. KLIP is reference-free. Primary MRI detection uses mask-free checkerboard inpainting: a total-variation reconstruction is regenerated in alternating 16mm16\mathrm{mm} squares, and the mean of 16 healthy inpaintings is treated as fixed. We average ten reference seeds. Thresholds are fitted only on healthy part 0 and frozen for parts 1–3. The expert-mask oracle is a supplementary control (§ 18). CT uses the lesion-free image, and photoacoustics uses the healthy twin.

Metrics. We evaluate anomaly preservation through recovered lesion amplitude in CT and lesion-to-background contrast recovery in MRI. Both are expressed relative to the ground truth: 100% indicates full recovery, while values near zero indicate suppression. Contrast error is the mean absolute departure from full recovery. Reconstruction fidelity is measured by the root mean squared error (RMSE) of the ensemble mean, reported separately within lesions and over the body or normal anatomy to distinguish preservation from overall image quality. RMSE is expressed in HU for CT and as a percentage of median intensity for MRI and photoacoustics. For CT and MRI, whole-image SSIM of the ensemble mean measures structural fidelity (dimensionless; Sec. S5.4). For downstream detection, area under the receiver operating characteristic curve (AUROC) ranks reconstructions by their largest detection score. Subtraction uses threshold-normalized ∣t∣|t| scores and KLIP uses likelihood-update scores. Det5_5 measures sensitivity at a separately swept threshold giving each method a matched 5% false-alarm rate on healthy test slices. An anomaly counts as detected only when a flag overlaps it. In MRI, Sens.val and FAval report test sensitivity and false alarms at thresholds fitted to a 5% healthy-validation false-alarm target and frozen before testing. MRI AUROC and slice sensitivity average four predefined tumor-size classes. False alarms (FA) at the preset Bonferroni threshold (α=5%\alpha= 5\%) assess performance without threshold adjustment. Free-response receiver operating characteristic (FROC) analysis instead counts localized lesion detections and false marks on all evaluated reconstructions; [email protected] is lesion sensitivity at 0.25 false-positive marks per evaluated image, or per evaluated slice for MRI. This operating point is selected on the test FROC curve.

Anomaly preservation and reconstruction fidelity

The size of the effect depends on the sampler and the measurement. For inserted CT lesions, with known amplitude and acquisition uncertainty, cFM and EDM recover 61–62% of lesion contrast without anchoring and 78–79% with deterministic anchoring. The four data-step samplers already recover 72–85% and gain 0.4–2.5 points. Lesion RMSE falls for five of the six pairs and is unchanged for P-DDIM (Table S1). In photoacoustics, stochastic anchoring halves lesion error for cFM and DPS and leaves DDNM, whose error was already low, unchanged (Table S6).

Table 1: Deterministic anchoring

SamplerLesion RMSEContrastAUROCDet5_5F1FA
cFM64.460.770.933.125.848.6
+ anchoring59.178.285.566.862.17.1
EDM63.762.372.534.930.230.7
+ anchoring59.379.285.166.964.84.4
DDRM65.281.282.559.131.9100.0
+ anchoring63.182.684.365.661.56.8
DDNM81.585.381.359.632.4100.0
+ anchoring77.385.784.666.365.23.6
DiffPIR61.174.983.055.936.844.3
+ anchoring59.876.684.765.665.21.9
P-DDIM59.072.282.057.728.277.8
+ anchoring59.174.784.365.564.33.2
AnchoredFM59.578.985.166.662.86.0

Table 1: Stochastic diagnostics

SamplerSSIMCov.Det5_5
cFM0.871→0.84969.7→82.857.2
EDM0.871→0.84976.7→87.359.2
DDRM0.812→0.80663.4→87.855.5
DDNM0.747→0.74061.2→91.757.2
DiffPIR0.842→0.84785.5→90.756.5
P-DDIM0.856→0.85081.1→88.656.2
AnchoredFM0.871→0.84669.7→85.657.3

Table 1: Control

ControlLesion RMSESSIMCov.AUROCDet5_5FA
Gaussian posterior680.72493.782.055.22.8
exact test–––82.360.79.7
Ideal observer–––89.776.40.8

Table S1. CT256 at 64 views: 1080 lesion and 720 healthy slices from 45 patients, against the ideal reference. Left: default deterministic anchoring. Right: secondary stochastic comparison; arrows denote base→stochastic, except Det5_5, which is stochastic only. RMSE is in HU, SSIM dimensionless and other values in %. Bold and italic denote better or worse paired results after Holm adjustment; deterministic detection columns and control rows are unmarked point estimates. Coverage is for nominal 90% lesion-pixel intervals. AnchoredFM is compared with cFM.

Table S6. Stochastic PAT at 64 detectors: 78 lesion phantoms and healthy twins from 27 anatomies. Each entry is base→\toanchored; AnchoredFM uses cFM as its base. RMSE is in % of median initial pressure; other values are in %, with marks as in Table S1. Coverage is for nominal 90% lesion-pixel intervals.

SamplerLesion RMSECov.Det5_5FA
cFM49.4→\to24.322.3→\to64.720.1→\to98.173.1→\to5.1
DPS52.1→\to25.637.3→\to69.40.0→\to98.1100.0→\to3.8
DDNM22.8→\to22.424.8→\to69.599.4→\to98.7100.0→\to2.6
AnchoredFM49.4→\to24.122.3→\to64.820.1→\to98.773.1→\to5.1

Table S6.

In MRI at nominal noise the base samplers already retain

89–93% of tumor contrast and anchoring adds about one point on average (Table S4). Even so, mean tumor RMSE across the eight sampler pairs falls from 11.5% to 11.0% of median brain intensity and mean absolute contrast error from 8.4% to 7.3% although DPS contrast error rises from 7.2% to 7.7% (Table 1). The benefit grows with acquisition noise: for the four zero-shot samplers tested under stochastic anchoring, contrast recovery improves by 0.0–1.4 points at the nominal level and by 1.8–10.0 points at eight times that level, where the base samplers retain only 72–84% (Table S8). Anchoring also lowers mean whole-image SSIM from 0.950 to 0.804 (Table S4). The drop is the measurement noise kept in the held coefficients. Putting the noisy held readings into the unanchored reconstructions gives 0.797 and into the true images 0.843, with SSIM of 0.990 inside the brain and 0.810 in the empty background (Table S20).

SamplerTumor RMSEContrast recoveryContrast errorSSIM
cFM13.988.911.10.947
+ anchoring12.291.88.40.741
EDM11.790.79.40.954
+ anchoring10.893.07.10.749
DPS11.092.97.20.946
+ anchoring11.092.47.70.886
ΠGDM10.992.57.60.953
+ anchoring10.892.57.60.855
DDRM11.690.89.30.946
+ anchoring11.292.47.80.782
DDNM11.193.17.00.944
+ anchoring11.093.66.60.814
DiffPIR11.092.47.70.952
+ anchoring10.693.96.30.788
P-DDIM11.091.88.30.954
+ anchoring10.892.87.30.815
AnchoredFM12.390.89.30.729
Eight-sampler mean11.591.68.40.950
+ anchoring11.092.87.30.804
Gaussian posterior16.984.815.50.546

Table S4. MRI reconstruction at 64 of 256 lines: default deterministic anchoring and a 16-sample Gaussian-posterior control. RMSE (% of median brain intensity) and contrast metrics (%) use 661 tumor slices; whole-image SSIM uses all 1362 test slices. Bold and italic denote better or worse paired reconstruction after Holm adjustment; contrast-recovery marks use absolute contrast error. AnchoredFM is compared with cFM; the Gaussian row is unmarked.

Table S8. Stochastic MRI noise sweep endpoints. Contrast and coverage are in %; changes are anchored minus base. Contrast gains have paired patient-bootstrap 95% intervals; stars denote Holm-adjusted p<0.05p < 0.05 across four samplers at that noise level. Coverage is base→\toanchored. RMSE changes are in % of median brain intensity; normal tissue excludes a four-pixel tumor margin.

σ\sigmaSamplerκ\kappaBase contrastΔ\Delta contrastCov.Δ\Delta RMSEtumor_{\mathrm{tumor}}Δ\Delta RMSEnormal_{\mathrm{normal}}
0.088DDRM390.8+1.4 [1.1, 1.7]*61.7→\to72.0−0.30+0.12
DDNM1093.1+0.4 [0.3, 0.5]*67.6→\to72.7+0.04+0.23
ΠGDM3092.50.0 [−0.2, 0.1]71.3→\to72.1−0.06+0.04
Posterior-DDIM1092.4+0.6 [0.4, 0.7]*53.0→\to59.2−0.09+0.12
0.704DDRM171.5+10.0 [8.7, 11.5]*38.6→\to67.2−1.46+1.30
DDNM183.5+8.8 [8.1, 10.2]*52.8→\to63.6−1.80+1.10
ΠGDM181.9+3.2 [2.4, 4.2]*82.1→\to84.3−0.99+0.10
Posterior-DDIM174.6+8.6 [7.7, 9.6]*65.7→\to75.1−1.73+0.18

Table S8.

Table S20. Source of the SSIM decrease in 64-line MRI (1362 slices). Noise only: the true image with its held coefficients replaced by the noisy readings. Swap: the unanchored ensemble mean with the same replacement. Whole-image SSIM, settings as in Sec. S5.4. For the noise-only image, mean SSIM is 0.990 inside the brain and 0.810 in the background.

Samplerκ\kappaBaseNoise onlySwapAnchored
cFM10.9470.7780.7220.741
EDM10.9540.7780.7380.749
DPS1000.9460.9380.8860.886
IIGDM300.9530.8950.8500.855
DDRM30.9460.8190.7730.782
DDNM100.9440.8570.8120.814
DiffPIR30.9520.8190.7800.788
P-DDIM100.9540.8570.8160.815
Mean0.9500.8430.7970.804

Table S20.

Measurement-based uncertainty calibration

Across the eight matched MRI sampler pairs at 64 lines, nominal 90% ensemble intervals cover 68.3% of the held coefficients on average without anchoring and 90.0% with it, and every pair moves closer to nominal (Table S21). The largest corrections occur for samplers with severe under-coverage (DDNM 32.0%, P-DDIM 57.2%, DDRM 64.3%).

Table S21. Coverage (%) of the held coefficients by nominal 90% ensemble intervals in 64-line MRI, parts 1–3, with patient-bootstrap 95% intervals for the base samplers. Anchored values are from stochastic anchoring; deterministic anchoring uses the analytic intervals of Tab. S5.

SamplerBaseAnchored
cFM84.2 [83.8, 84.6]90.0
EDM90.6 [90.4, 90.8]90.0
DPS76.1 [75.7, 76.5]90.0
IIGDM75.3 [75.0, 75.7]90.0
DDRM64.3 [64.0, 64.4]90.0
DDNM32.0 [31.6, 32.4]90.0
DiffPIR66.7 [66.5, 67.0]90.0
P-DDIM57.2 [56.7, 57.7]90.0
Mean68.390.0

Table S21.

cFM starts at 84.2%, and EDM is already near nominal at 90.6%. Anchoring therefore brings different uncertainty behaviors to one measurement-defined level. These directions span healthy and anomalous anatomy, so the check extends beyond lesions and tests the prediction of Proposition 1. The analytic intervals of deterministic anchoring cover 90.0–90.1% at every κ\kappa (Table S5).

κ\kappaHeld directionsAll slices [95% CI]Tumor slicesHealthy slices
1483390.01 [89.99, 90.03]89.9990.02
3266390.00 [89.97, 90.03]90.0090.00
10140190.00 [89.96, 90.04]89.9890.02
3075790.02 [89.96, 90.08]90.0090.04
10034790.06 [89.98, 90.14]90.0590.07

Table S5. Analytic held-coordinate coverage (%) of nominal 90% intervals in 64-line MRI. Intervals use known acquisition variance; patient-bootstrap 95% intervals assess this coordinate-level acquisition diagnostic.

Inside lesions, mean coverage under stochastic anchoring rises from 72.9% to 88.2% across the six CT pairs and from 28.1% to 67.9% across the three photoacoustic pairs, with every pair improving (Table S1 and Table S6). In MRI it rises for seven of the eight samplers, falling only for DPS. It also stays below nominal at 59.2–84.2% (Table S3). Pixels combine held and generated components, so nominal held-coordinate coverage does not imply nominal coverage throughout a lesion. For the same reason, the unadjusted Bonferroni threshold flags every healthy MRI slice under the checkerboard reference, requiring threshold fitting on healthy validation slices (§ 18).

SamplerBaseStochastic
cFM62.971.2
EDM77.979.2
DPS85.184.2
Π\PiGDM71.372.1
DDRM61.772.0
DDNM67.672.7
DiffPIR54.668.2
P-DDIM53.059.2
AnchoredFM62.968.2

Table S3. Nominal 90% tumor-pixel coverage (%) under stochastic anchoring in 64-line MRI: 661 tumor and 701 healthy slices from 60 patients. This secondary P-DDIM comparison uses its implicit default η0\eta_0, whereas the primary matched cohort uses η0=0\eta_0 = 0. Marks indicate movement toward or away from 90% after Holm adjustment. AnchoredFM is compared with cFM.

Downstream detection

Better lesion preservation retains the signal needed for detection, while more reliable uncertainty helps distinguish that signal from reconstruction error. Across all eight matched MRI sampler pairs with the checkerboard healthy reference at 64 lines, deterministic anchoring raises mean sensitivity at validation-frozen thresholds from 20.2% to 44.1%, while realized false alarms remain similar (3.2% and 3.3%). AUROC rises from 78.4% to 84.6% (Table S16). The largest gains occur for samplers that fail without anchoring (DDNM 2.3%, P-DDIM 11.6%). The gap between the best and worst of the eight samplers shrinks from 39.0 to 6.8 points. EDM, the strongest base sampler, still gains 3.9 points (Table S17).

Sampler32 lines deterministic32 lines stochastic64 lines deterministic64 lines stochastic
cFM+22.2 [+17.7, +26.6]+19.6 [+15.5, +23.6]+23.3 [+18.8, +27.8]+19.1 [+15.6, +22.8]
EDM+1.1 [−1.4, +3.4]−3.8 [−6.5, −1.1]+3.9 [+1.5, +6.4]−1.1 [−3.6, +1.2]
DPS+20.4 [+15.5, +25.1]+14.9 [+10.8, +18.8]+24.2 [+19.7, +28.8]+15.6 [+12.1, +18.8]
ΠGDM+20.9 [+16.3, +25.6]+14.9 [+11.3, +18.5]+21.4 [+17.2, +25.8]+15.7 [+12.1, +19.4]
DDRM+19.0 [+14.5, +23.6]+12.6 [+9.1, +16.2]+27.4 [+21.9, +32.6]+21.3 [+17.2, +25.6]
DDNM+27.7 [+22.6, +32.9]+19.2 [+15.4, +23.1]+41.2 [+34.6, +47.5]+35.7 [+29.8, +41.6]
DiffPIR+30.3 [+24.9, +35.5]+21.2 [+16.8, +25.6]+16.1 [+12.1, +20.0]+7.8 [+4.9, +10.9]
P-DDIM+30.1 [+24.6, +35.8]+27.2 [+22.1, +32.2]+33.4 [+27.0, +39.6]+25.0 [+19.5, +30.3]
AnchoredFM+21.3 [+17.0, +25.5]+18.4 [+14.5, +21.9]+23.0 [+18.5, +27.4]+22.2 [+18.5, +25.9]
Eight-sampler mean+21.5 [+17.7, +25.3]+15.7 [+12.8, +18.5]+23.8 [+19.6, +27.8]+17.4 [+14.3, +20.4]

Table S17. Primary matched checkerboard MRI cohort: frozen-threshold sensitivity differences from each matched base sampler, in points with paired patient and seed bootstrap 95% intervals. Det. includes analytic held variance. AnchoredFM is compared with cFM.

Anchoring also helps a detector from prior work. With the reference-free KLIP readout [27] on the shared DPS prior, deterministic anchoring raises AUROC from 83.7% to 93.7% and Det5_5 from 55.1% to 71.2% (Table 1 and § 14.4), the highest of any pipeline in the MRI test (anchored subtraction averages 84.6% and 49.0%; Table S16).

Detection performance varies with the quality of the healthy reference. In the oracle comparison, access to the true image and lesion masks yields near-perfect AUROC and Det5_5 even without anchoring. Anchoring still improves lesion localization: at 64 MRI lines, mean sensitivity across eight sampler pairs rises from 67.4% to 82.2% at 0.25 false-positive marks per slice. Preset false alarms fall from 67.9% to 9.0%, although they remain above the nominal 5% target (Table S18). Checkerboard inpainting builds the reference without lesion masks and provides a more practical test. It can still alter healthy anatomy or retain lesion signal, leading to false alarms or missed lesions.

Sampler[email protected]FA
cFM65.7→85.839.7→23.7
EDM66.9→83.414.6→4.4
DPS67.1→72.439.7→2.0
ΠGDM66.0→80.859.6→5.3
DDRM69.3→83.192.9→5.6
DDNM67.1→82.499.7→4.4
DiffPIR67.6→86.098.3→11.7
P-DDIM69.8→83.899.1→14.7
AnchoredFM65.7→86.639.7→49.8
Eight-sampler mean67.4→82.267.9→9.0

Table S18. Deterministic MRI oracle control, 64 lines, seed 0. Entries are base→anchored (%); AnchoredFM is compared with cFM. AUROC is 100.0% throughout and Det₅ is 99.9–100.0%, illustrating oracle saturation. Saved per-slice scores independently confirm 278/701 preset false alarms (39.7%) for both cFM and DPS; their alarm sets differ.

Detection across tumor sizes

The detection gain holds across tumor sizes. We divide the MRI lesions into four predefined equivalent-diameter groups and, for each sampler, apply one globally selected FROC threshold to every group (Table 2). At 0.25 false-positive marks per slice, deterministic anchoring raises mean sensitivity in all four groups. For the smallest 11–23 mm tumors it rises from 6.9% to 10.1%, although sensitivity for these tumors remains low, and over all lesions the gain is +8.8 points. Full per-method results and the oracle control are in Table S18 and Table S19.

Sampler11–23 mm23–34 mm34–45 mm≥45 mmAll
cFM9.134.855.872.740.8
+ anchoring11.645.568.279.949.0
difference+2.5 [−0.7, +6.0]+10.7 [+4.7, +16.1]+12.4 [+7.4, +17.3]+7.3 [+3.3, +11.6]+8.2 [+5.7, +10.4]
EDM10.338.365.178.545.6
+ anchoring10.743.267.578.847.7
difference+0.5 [−2.9, +4.1]+4.9 [−0.3, +9.1]+2.5 [−0.3, +5.2]+0.3 [−3.5, +3.0]+2.1 [−0.6, +4.2]
DPS5.126.950.265.034.6
+ anchoring8.838.465.277.945.1
difference+3.7 [+1.0, +6.3]+11.5 [+6.6, +16.2]+15.0 [+9.9, +20.4]+12.8 [+6.7, +20.2]+10.5 [+7.9, +13.3]
ΠGDM6.132.961.076.941.7
+ anchoring9.442.166.678.846.8
difference+3.3 [+0.6, +6.0]+9.2 [+4.7, +14.0]+5.6 [+2.2, +9.9]+1.9 [−1.9, +7.1]+5.2 [+2.7, +8.0]
DDRM6.427.154.474.838.1
+ anchoring10.041.967.879.047.3
difference+3.6 [+0.2, +6.8]+14.8 [+10.0, +19.8]+13.4 [+8.5, +19.5]+4.2 [−0.1, +8.4]+9.2 [+6.5, +11.7]
DDNM4.420.040.958.829.0
+ anchoring10.443.767.479.547.9
difference+5.9 [+2.6, +9.8]+23.7 [+18.1, +29.3]+26.5 [+19.8, +33.6]+20.6 [+12.5, +28.2]+18.9 [+15.5, +22.2]
DiffPIR8.530.862.575.141.7
+ anchoring10.845.267.880.148.6
difference+2.3 [−0.2, +5.1]+14.4 [+9.3, +19.2]+5.3 [+0.7, +10.4]+5.0 [+0.9, +8.6]+6.9 [+4.2, +9.3]
P-DDIM5.729.655.773.638.7
+ anchoring9.444.467.580.148.0
difference+3.7 [−0.0, +8.1]+14.8 [+9.3, +20.4]+11.8 [+7.5, +17.5]+6.5 [+1.8, +11.4]+9.3 [+6.9, +12.0]
cFM9.134.855.872.740.8
AnchoredFM12.546.068.780.449.6
difference+3.4 [+0.1, +6.4]+11.3 [+6.0, +16.3]+12.9 [+7.8, +17.5]+7.7 [+3.5, +12.3]+8.8 [+6.3, +11.0]
Eight-sampler mean6.930.155.771.938.8
+ anchoring10.143.067.379.347.5
difference+3.2 [+1.0, +5.5]+13.0 [+9.5, +16.5]+11.6 [+8.3, +15.2]+7.3 [+4.3, +10.4]+8.8 [+6.9, +10.6]

Table S19. Checkerboard MRI with deterministic anchoring at 64 lines: per-method FROC sensitivity at 0.25 false marks per slice by predefined tumor size. Every run shares one global threshold across size groups. The separate cFM–AnchoredFM comparison is excluded from the eight-sampler mean.

AnchoredFM sampling efficiency

In a CT runtime study on one H100 (128 grid, 64 views), AnchoredFM generates a 16-sample ensemble in 5.9 ms with one network evaluation per sample. Among learned samplers completing within 12 ms, it achieves the lowest contrast and coverage errors, while anchored cFM achieves lower lesion RMSE. Compared with the best full-budget learned results, lesion RMSE is 8.9% higher and contrast error is 0.7 points higher, while sampling is 74× faster than full-budget anchored cFM. A budget of this size matters when reconstruction must keep pace with acquisition, as in real-time or interactive MRI, where a multi-sample ensemble is otherwise too slow to produce for every frame. Figure 3 shows the runtime–quality trade-off; full numerical comparisons are in § 16.

Figure 3. Stochastic-anchoring CT runtime study (128 grid, 64 views): contrast error (left) and coverage error (right) versus runtime for 16 samples, evaluated on 432 lesion reconstructions from 45 test patients (parts 1–3). AnchoredFM and anchored cFM vary their step budgets. Other samplers use full budgets. Contrast error is the mean absolute deviation from full recovery; coverage error is the absolute deviation from 90% coverage.

Discussion and limitations

Our results distinguish anatomical fidelity from the preservation of abnormality. Global image similarity and lesion-specific metrics do not always improve together, as clinical reader and detection studies have also found [21, 22], motivating separate assessment of anatomical reconstruction and retained lesion evidence. Selective anchoring handles this trade-off by protecting reliable measurement-derived components while using the learned prior to reconstruct unresolved structure.

Lesion contrast and uncertainty play complementary roles in detection. Preserving contrast retains the signal of an abnormality, while uncertainty helps assess whether a residual could be explained by reconstruction error. Under-estimated uncertainty in healthy tissue can therefore create false alarms despite visually plausible images. This motivates assessing retained lesion evidence and uncertainty together, with measurement-based guarantees providing a reference for the protected components. Anchoring’s largest detection gains occur for samplers whose data steps reuse the same readings in every sample, although no single mechanism explains all samplers; after anchoring, detection depends far less on which sampler is used.

Choosing κ\kappa. Smaller κ\kappa protects more measured directions but retains more noise; larger κ\kappa leaves more to the prior. For independent Gaussian singular coordinates, anchored variance is at most 1+1/κ1+1/\kappa times posterior variance (Sec. S2.2). This criterion measures relative measurement reliability rather than lesion relevance, and AnchoredFM requires separate training for each κ\kappa.

What anchoring cannot do. Anchoring directly protects only well-measured anomaly components, and its uncertainty guarantees apply only to held coordinates. Overconfidence in free components can still cause false alarms, particularly in MRI, where most directions are free. Subtraction also depends on a healthy reference that may retain lesions or alter normal anatomy. Estimating uncertainty from 16 samples further limits detection power.

Assumptions. We assume a known linear operator and noise level. The exact Student tt law requires a held-only template, an exact healthy reference, Gaussian acquisition noise, and independent Gaussian anchoring draws (Proposition 2). Operator error about ten times the noise worsens lesion reconstruction for every anchored photoacoustic sampler (§ 13.2). Underestimating CT noise by 20% raises false alarms to 13.1–18.2% in the 128-grid test. On the 256 grid at 64 views, the residual outside the range of AA estimates noise at 1.048 times its true level (§ 13.3). The stationary Gaussian surrogate used for selection ignores correlations between singular directions. CT data steps use per-sample readings with effective noise 2σ\sqrt{2}\sigma; assuming σ\sigma substantially worsens DDRM and DDNM reconstruction. MRI and photoacoustics use shared readings, which left these samplers overconfident in CT (Sec. S7.2).

Scope of the evaluation. All acquisitions are simulated. MRI readings are generated from magnitude images using the reconstruction operator, an implicit data crime [44]. Performance on raw multi-coil MRI remains untested.

Conclusion. Selective anchoring preserves well-measured lesion contrast in expectation while a learned prior reconstructs unresolved anatomy. Across the tested modalities, anchoring improves anomaly preservation and uncertainty reliability. With checkerboard-inpainting references in MRI, deterministic anchoring raises mean localized lesion sensitivity from 38.8% to 47.5% at 0.25 false-positive marks per slice, with improvements across all four predefined tumor-size groups. Selective anchoring lets the prior complete what the measurements leave unresolved, without healing away abnormalities they support.

LLM Usage Statement

Claude Code (Claude Fable 5-family models) was used to assist with writing and running the experiment and analysis code, under human direction, and with drafting and reviewing the manuscript. ChatGPT and OpenAI Codex (Solfamily models) were also used for writing assistance (comparing drafts, revising text, searching related work) and to draw the method figure. All research ideation, experimental design, and scientific conclusions are the authors’ own. The authors take full responsibility for all content in this paper.

Acknowledgements

This material is based upon work supported by the U.S. National Science Foundation under Award No. CBET-2143625. J.C. is partially supported by the Jack Kent Cooke Foundation. This research was performed using computational resources sponsored by the U.S. Department of Energy’s Office of Critical Minerals and Energy Innovation and located at the National Laboratory of the Rockies. Any opinions, findings, and conclusions or recommendations expressed in this material are those of the authors and do not necessarily reflect the views of the National Science Foundation.

Do Not Let the Prior Heal the Anomaly: Selective Anchoring for Detection from Incomplete Measurements

Deterministic anchoring with analytic held acquisition variance is the default for computed tomography (CT) and magnetic resonance imaging (MRI); labeled stochastic studies are secondary. Numbered citations without an S prefix refer to the main-paper bibliography.

Implementation of selective anchoring

The ratio in Eq. (4) selects readings that are precise relative to normal-image variability. The Gaussian calculation in Sec. S2.2 quantifies their shrinkage–variance trade-off. Preservation and analytic coverage concern the selected singular coordinates; pixels also contain generated free components.

Pretrained wrapper. The sampler uses the wrapped clean prediction in Eq. (6) with its original conditioning and projects the returned image to the same anchor. Intermediate noisy states need not satisfy this constraint. For a flow, the wrapped velocity is (D′−xt)/(1−t)(D' - x_t)/(1-t) for t<1t < 1. Additional data updates use only the remaining measurements, as detailed in Sec. S7.2.

AnchoredFM. Training uses clean held coefficients and a Gaussian-surrogate maximum a posteriori (MAP) image of fresh noisy measurements as conditioning. Inference instead uses measurement-derived held inputs: fixed under deterministic anchoring or independently perturbed under stochastic anchoring. Both differ from the clean training inputs. Projected Euler integration preserves the held state exactly and requires no products with AA or ATA^{\mathsf T} after computing the lift and MAP image, avoiding the per-step cost of forward-model and adjoint evaluations.

Detection. The exact held-only null laws for the scores of Eq. (9) are proved in § 9.4. Their Bonferroni guarantee requires those null laws; mixed templates and estimated references require empirical calibration. The practical MRI thresholds are specified in § 18.

Proofs

Write y~i=zi+ei\tilde{y}_i = z_i + e_i, where ei=uiTε/si∼N(0,ni)e_i = u_i^{\mathsf T}\varepsilon/s_i \sim\mathcal{N}(0,n_i) and ni=σ2/si2n_i = \sigma^2/s_i^2. Orthonormality of the uiu_i makes the eie_i mutually independent and independent of the fixed image.

Proof of Proposition 1

Deterministic anchoring fixes each held coefficient at y~i\tilde{y}_i. Stochastic anchoring adds an independent draw ei′∼N(0,ni)e_i' \sim\mathcal{N}(0,n_i). Write UH=[ui]i∈HU_H = [u_i]_{i\in H} and sH=(si)i∈Hs_H = (s_i)_{i\in H} for the selected left singular vectors and singular values. For η∼N(0,Im)\eta\sim\mathcal{N}(0,I_m) independent of acquisition noise,

Cov⁡(σdiag⁡(sH)−1UHTη)=σ2diag⁡(sH)−2.\operatorname{Cov}\left(\sigma\operatorname{diag}(s_H)^{-1}U_H^{\mathsf T}\eta\right)=\sigma^2\operatorname{diag}(s_H)^{-2}.

Both therefore give E[PH(xˉ−b)]=PHℓ\mathbb{E}[P_H(\bar{x}-b)] = P_H\ell over acquisition noise and, for stochastic anchoring, the target draws. Write Φ\Phi for the standard-normal CDF, Ft,νF_{t,\nu} for the Student CDF with ν>0\nu>0 degrees of freedom, and tp,ν=Ft,ν−1(p)t_{p,\nu}=F_{t,\nu}^{-1}(p) for 0<p<10<p<1. For coverage level γ∈(0,1)\gamma\in(0,1), let qγ=Φ−1((1+γ)/2)q_\gamma=\Phi^{-1}((1+\gamma)/2). The analytic interval y~i±qγni\tilde{y}_i\pm q_\gamma\sqrt{n_i} contains ziz_i exactly when ∣ei∣≤qγni|e_i|\le q_\gamma\sqrt{n_i}, an event of probability γ\gamma for every fixed image. □

A Gaussian prior

When ATAA^{\mathsf T}A and CC commute, the ratios rir_i are likelihood-informed eigenvalues in a shared eigenbasis [45, 46].

Proposition S1. Suppose also that the prior has independent zi∼N(mi,pi)z_i\sim\mathcal{N}(m_i,p_i), where mi=viTμm_i=v_i^{\mathsf T}\mu and pi=viTCvi>0p_i=v_i^{\mathsf T}Cv_i>0, and write ci=ri/(1+ri)c_i=r_i/(1+r_i).

(a) In a held direction, the conditional variance of a stochastic anchored sample is 1/ci=1+1/ri<1+1/κ1/c_i=1+1/r_i<1+1/\kappa times the exact posterior variance. The same ratio holds for single-sample squared error averaged over the Gaussian prior, acquisition noise and sampling noise, but need not hold for a fixed image.

(b) Given ziz_i, the exact posterior’s standardized error has mean δi/1+ri\delta_i/\sqrt{1+r_i} and variance cic_i, where δi=(zi−mi)/pi\delta_i=(z_i-m_i)/\sqrt{p_i}. Its central intervals have nominal prior-averaged coverage, but need not have nominal coverage for a fixed component.

Proof. The Gaussian posterior mean MiM_i and variance satisfy

Var⁡(zi∣y)=cini,Mi=viTx^(y)=mi+ci(y~i−mi).\operatorname{Var}(z_i\mid y)=c_i n_i,\qquad M_i=v_i^{\mathsf T}\hat{x}(y)=m_i+c_i(\tilde{y}_i-m_i).

The anchored draw has conditional variance nin_i, giving (a). Its prior-averaged squared error is 2ni2n_i, while a posterior draw has error 2cini2c_i n_i because truth and draw are conditionally independent posterior samples. For (b),

zi−Mi=(1−ci)(zi−mi)−ciei.z_i-M_i=(1-c_i)(z_i-m_i)-c_i e_i.

Dividing by cini\sqrt{c_i n_i} gives the stated fixed-component mean and variance. Averaging over δi∼N(0,1)\delta_i\sim\mathcal{N}(0,1) gives total variance 1/(1+ri)+ci=11/(1+r_i)+c_i=1. Components far from the prior mean, ∣δi∣≫1+ri|\delta_i|\gg\sqrt{1+r_i}, can nevertheless lie outside posterior intervals more often than nominal. □

Detection laws and uncertainty treatments

Assume Eq. (2), the exact healthy reference r=br=b, K≥2K\ge2, and w≠0w\ne0. The template is fixed, so we omit its position argument in aj(p)a_j(p). Put wF=Πww_F=\Pi w and

τ2=∑i∈Hni⟨vi,w⟩2⟨w,w⟩2.\tau^2=\sum_{i\in\mathcal{H}}n_i\frac{\langle v_i,w\rangle^2}{\langle w,w\rangle^2}.

For a held-only template, stochastic anchoring under a fixed anomaly gives a noncentral tK−1t_{K-1} score with

δ=⟨w,ℓ⟩⟨w,w⟩τ1+1/K.\delta=\frac{\langle w,\ell\rangle}{\langle w,w\rangle\tau\sqrt{1+1/K}}.

Under the null ℓ=0\ell=0, the following mixed-template Gaussian calculation is a diagnostic rather than a guarantee for a learned generator. Let uncentered free sample amplitudes be i.i.d. N(μF,vF)\mathcal{N}(\mu_F,v_F) and the true free amplitude be an independent N(μF,λvF)\mathcal{N}(\mu_F,\lambda v_F) draw, independent also of held acquisition noise and anchor draws. With vF>0v_F>0, λ≥0\lambda\ge0, and ρ=vF/(τ2+vF)\rho=v_F/(\tau^2+v_F), stochastic anchoring gives t=g Tt=\sqrt{g}\,T, T∼tK−1T\sim t_{K-1}, where

g=1+ρ(λ−1)KK+1.g=1+\rho(\lambda-1)\frac{K}{K+1}.

Deterministic anchoring without analytic held variance instead is variance divided by expected squared denominator

gdet=1+(1−ρρ+λ−1)KK+1.g_{\mathrm{det}}=1+\left(\frac{1-\rho}{\rho}+\lambda-1\right)\frac{K}{K+1}.

Adding τ2\tau^2 to (1+1/K)sa2(1+1/K)s_a^2 changes this ratio to

gcorr=1+ρ(λ−1)1+ρ/K.g_{\mathrm{corr}}=1+\frac{\rho(\lambda-1)}{1+\rho/K}.

The corrected mixed denominator contains a constant plus a scaled chi-squared variable and does not establish an exact Student law. Held-only deterministic scores instead have the known-variance normal law proved below.

Thresholds and analytic-variance implementation. Let P\mathcal{P} be the finite set of valid position–size pairs, Ntests=∣P∣N_{\mathrm{tests}}=|\mathcal{P}|, and α=0.05\alpha=0.05. For held-only templates and an exact healthy reference, the two-sided Bonferroni rules are

∣tstoch∣>FtK−1−1(1−α2Ntests),|t_{\mathrm{stoch}}|>F^{-1}_{t_{K-1}}\left(1-\frac{\alpha}{2N_{\mathrm{tests}}}\right),
∣zdet∣>Φ−1(1−α2Ntests).|z_{\mathrm{det}}|>\Phi^{-1}\left(1-\frac{\alpha}{2N_{\mathrm{tests}}}\right).

The held-template null laws give image-level false-alarm control by the union bound, without requiring independence across tests.

For the mixed-template CT analytic-variance comparison, write aj=ajH+ajFa_j=a_j^H+a_j^F. Let sF2s_F^2 and sHFs_{HF} be the unbiased sample variance of ajFa_j^F and sample covariance of ajH,ajFa_j^H,a_j^F. Here ajH=⟨PHw,xj−r⟩/⟨w,w⟩a_j^H=\langle P_Hw,x_j-r\rangle/\langle w,w\rangle and ajF=⟨wF,xj−r⟩/⟨w,w⟩a_j^F=\langle w_F,x_j-r\rangle/\langle w,w\rangle are scalar held and free residual amplitudes for sample j=1,…,Kj=1,\ldots,K. The implemented estimated and total variances and effective degrees of freedom are

vest=max⁡{(1+1/K)(sF2+2sHF),0},v_{\mathrm{est}}=\max\left\{(1+1/K)(s_F^2+2s_{HF}),0\right\},
vtot=vest+cHτ2,v_{\mathrm{tot}}=v_{\mathrm{est}}+c_H\tau^2,
ν=(K−1)(vtotvest)2(vest>0),\nu=(K-1)\left(\frac{v_{\mathrm{tot}}}{v_{\mathrm{est}}}\right)^2\qquad(v_{\mathrm{est}}>0),

where cH=1c_H=1 for deterministic anchoring and cH=1+1/Kc_H=1+1/K for stochastic anchoring with analytic held variance. At fixed positive held variance, vest→0v_{\mathrm{est}}\to0 gives the known-variance normal limit. Deterministic held amplitudes are constant across samples, so sHF=0s_{HF}=0 and vest=(1+1/K)sa2v_{\mathrm{est}}=(1+1/K)s_a^2. CT maps ∣a∣/vtot|a|/\sqrt{v_{\mathrm{tot}}} through its tνt_\nu cumulative distribution to the corresponding standard-normal quantile and uses the normal Bonferroni threshold above. This Satterthwaite convention is an approximation for mixed templates; the exact laws concern held-only templates. MRI instead uses the tK−1t_{K-1} score normalization and healthy-validation-frozen thresholds specified in § 18.

Remark S1 (Propagation of a held perturbation). For fixed yy, let hh be the random held anchor, aHa^H its held residual amplitude, and aF=gF(h,Z)a^F=g_F(h,Z) the free residual amplitude, with independent generator randomness ZZ and finite second moments. Total variance gives

Var⁡(aH+aF)=Var⁡(aH)+E[Var⁡(aF∣h)]+Var⁡(E[aF∣h])+2Cov⁡(aH,E[aF∣h]).\operatorname{Var}(a^H+a^F)=\operatorname{Var}(a^H)+\mathbb{E}[\operatorname{Var}(a^F\mid h)] +\operatorname{Var}(\mathbb{E}[a^F\mid h])+2\operatorname{Cov}(a^H,\mathbb{E}[a^F\mid h]).

Generating at a fixed anchor and adding an independent held perturbation afterward does not reproduce the last two terms in general. The terms vanish for independent held and free frequencies in a stationary Gaussian Fourier prior, and may be small for low-noise held directions.

Proof of Proposition 2

The Satterthwaite degrees of freedom are given in § 9.3. Write aj=⟨w,xj−r⟩/⟨w,w⟩=ajH+ajFa_j=\langle w,x_j-r\rangle/\langle w,w\rangle=a_j^H+a_j^F and βi=⟨vi,w⟩/⟨w,w⟩\beta_i=\langle v_i,w\rangle/\langle w,w\rangle. Under the held-only null, independent acquisition and anchoring noises give

ajH=∑i∈Hβi(ei+eij′)=τ(ϵ0+ϵj),a_j^H=\sum_{i\in\mathcal{H}}\beta_i(e_i+e'_{ij})=\tau(\epsilon_0+\epsilon_j),

with independent standard normal ϵ0,ϵ1,…,ϵK\epsilon_0,\epsilon_1,\ldots,\epsilon_K; eij′e'_{ij} is sample jj’s independent copy of ei′e'_i. Set ϵˉ=K−1∑j=1Kϵj\bar{\epsilon}=K^{-1}\sum_{j=1}^K\epsilon_j and S2=(K−1)−1∑j=1K(ϵj−ϵˉ)2S^2=(K-1)^{-1}\sum_{j=1}^K(\epsilon_j-\bar{\epsilon})^2. Thus aˉ=τ(ϵ0+ϵˉ)\bar{a}=\tau(\epsilon_0+\bar{\epsilon}) and sa2=τ2S2s_a^2=\tau^2S^2. Cochran’s theorem gives (K−1)S2∼χK−12(K-1)S^2\sim\chi^2_{K-1} independently of ϵ0+ϵˉ\epsilon_0+\bar{\epsilon}, whose variance is 1+1/K1+1/K. Hence aˉ/(sa1+1/K)∼tK−1\bar{a}/(s_a\sqrt{1+1/K})\sim t_{K-1}. An anomaly adds ⟨w,ℓ⟩/⟨w,w⟩\langle w,\ell\rangle/\langle w,w\rangle, yielding the noncentrality above. Deterministic anchoring uses the fixed held readings, whose null amplitude is τϵ0\tau\epsilon_0; division by known τ\tau gives N(0,1)\mathcal{N}(0,1). For the mixed Gaussian diagnostic under the null, define uncentered free amplitudes a~jF=⟨wF,xj⟩/⟨w,w⟩\widetilde{a}^{F}_{j}=\langle w_{F},x_{j}\rangle/\langle w,w\rangle and a~⋆F=⟨wF,x⟩/⟨w,w⟩\widetilde{a}^{F}_{\star}=\langle w_{F},x\rangle/\langle w,w\rangle. Since r=b=xr=b=x, the residual amplitude is ajF=a~jF−a~⋆Fa^{F}_{j}=\widetilde{a}^{F}_{j}-\widetilde{a}^{F}_{\star}. So aj=τ(ϵ0+ϵj)+a~jF−a~⋆Fa_{j}=\tau(\epsilon_{0}+\epsilon_{j})+\widetilde{a}^{F}_{j}-\widetilde{a}^{F}_{\star}. The numerator variance is τ2(1+1/K)+vF/K+λvF\tau^{2}(1+1/K)+v_{F}/K+\lambda v_{F}, while (K−1)sa2/(τ2+vF)(K-1)s_{a}^{2}/(\tau^{2}+v_{F}) is an independent χK−12\chi^{2}_{K-1}. Their ratio yields gg. Deterministic anchoring removes ϵj\epsilon_{j}, leaving numerator variance τ2+vF/K+λvF\tau^{2}+v_{F}/K+\lambda v_{F} and mean squared sample denominator (1+1/K)vF(1+1/K)v_{F}. Adding τ2\tau^{2} to that denominator yields gcorrg_{\mathrm{corr}}.

Metrics

Contrast is lesion-profile recovery relative to truth in CT and PAT, and tumor-to-ring contrast recovery in MRI; full recovery is 100%. Reconstruction metrics are root-mean-square error (RMSE), in Hounsfield units (HU) for CT, and the structural similarity index (SSIM; Sec. S5.4). At one pixel, let x⋆x_{\star}, xˉ\bar{x} and spixs_{\mathrm{pix}} denote its true intensity, ensemble mean and sample standard deviation (from the unbiased sample variance). For the labeled stochastic studies, its nominal 90% interval covers the truth if ∣x⋆−xˉ∣<t0.95,K−11+1/K spix|x_{\star}-\bar{x}|<t_{0.95,K-1}\sqrt{1+1/K}\,s_{\mathrm{pix}}. Lesion coverage (Cov.) averages over the expert MRI mask or the inserted lesion support above 5% of peak magnitude in CT and photoacoustic tomography (PAT). Deterministic held-coordinate intervals instead use analytic acquisition variance (Table S5 and Table S21).

Sens.val and FAval denote sensitivity and false-alarm rate (FA) at the healthy-validation-frozen threshold; partial area under the curve (pAUC5) is reported as mean localized sensitivity over 0–5% FA. An image score is its maximum threshold-normalized ∣t∣|t|; the area under the receiver operating characteristic curve (AUROC) counts ties as one half. Det5 uses a retrospective cutoff giving 5% healthy-test FA. F1 uses the preset threshold and requires localization near the anomaly, with prevalence one anomalous to four healthy images: F1=2pdet/(1+pdet+4pFA)F_{1}=2p_{\mathrm{det}}/(1+p_{\mathrm{det}}+4p_{\mathrm{FA}}), where pdet,pFA∈[0,1]p_{\mathrm{det}},p_{\mathrm{FA}}\in[0,1] are the localized anomalous-image detection rate and healthy-image false-alarm rate. It is averaged over anomaly types. Confidence intervals (CIs) use 2000 paired bootstrap draws of patients (anatomies for PAT). Metric differences are signed; intervals including zero do not establish an improvement. Free-response receiver operating characteristic (FROC) and practical MRI threshold and inference details are in Secs. S6 and § 18.

Samplers and settings

Shared prior as a denoiser. For the shared unanchored flow prior, xt=(1−t)x0+tx1x_{t}=(1-t)x_{0}+tx_{1}, where x0∼N(0,Id)x_{0}\sim\mathcal{N}(0,I_{d}) is independent of the clean image x1x_{1} and 0<t≤10<t\leq1. Set σden=(1−t)/t\sigma_{\mathrm{den}}=(1-t)/t and xden=xt/t=x1+σdenx0x_{\mathrm{den}}=x_{t}/t=x_{1}+\sigma_{\mathrm{den}}x_{0}. InverseB… [S1] receives Dden(xden,σden)=D(txden,t)D_{\mathrm{den}}(x_{\mathrm{den}},\sigma_{\mathrm{den}})=D(tx_{\mathrm{den}},t), with t=1/(1+σden)t=1/(1+\sigma_{\mathrm{den}}) and the main text’s clean predictor DD. Here σden\sigma_{\mathrm{den}} is denoising noise; acquisition noise remains σ\sigma. Samplers operate on x−μx-\mu and y−Aμy-A\mu; μ\mu is added back afterward.

Validation grids and adaptations. Settings are selected on the validation partition (part 0), sweeping DPS guidance {0.3,1,3,10,30,100}\{0.3,1,3,10,30,100\}; NIGDM η∈{0,0.2,0.5,0.85,1}\eta\in\{0,0.2,0.5,0.85,1\}; DDRM η∈{0.5,0.85,1}\eta\in\{0.5,0.85,1\}; DDNM η∈{0.5,0.85}\eta\in\{0.5,0.85\}; Diff-PIR λ∈{1/16,1/4,1,8,32}\lambda\in\{1/16,1/4,1,8,32\}; P-DDIM η1∈{1,14,16}\eta_{1}\in\{1,14,16\}; and EDM steps {18,40}\{18,40\}. The baseline-specific η\eta controls injected sampling noise; P-DDIM’s η0,η1\eta_{0},\eta_{1} apply to observed and null-space directions, respectively. DiffPIR’s λ\lambda controls proximal regularization. cFM and AnchoredFM have no analogous main setting. PAT uses DPS guidance {1,3,10}\{1,3,10\}, DDNM η∈{0.5,0.85}\eta\in\{0.5,0.85\} and AnchoredFM κ∈{3,30}\kappa\in\{3,30\}. DDRM retains siσden,max>σs_{i}\sigma_{\mathrm{den,max}}>\sigma as in its original code, where σden,max\sigma_{\mathrm{den,max}} is the maximum denoising noise in the sampler selected, distinct from the operator singular values sis_{i}. DiffPIR uses its exact linear data step at noise σ\sigma. P-DDIM’s CT correction is capped at the reading to prevent overshoot and divergence; this stabilizes sampling but leaves too little spread in strongly measured directions.

Additional results

Teaser selection

For the main paper’s opening figure (the teaser), the lesion example is the median true contrast among detections gained after anchoring. The healthy example is the median unanchored score among removed false alarms whose maximum is inside valid anatomy and at least 64 pixels from every edge. Both show full slices.

CT

CT256 and CT128 denote CT reconstruction on the 256 and 128 grids, respectively. The twelve lesion types are 4, 8 and 16 mm discs at +50, +150 and +400 HU, an 8 mm disc at −100 HU, a 10 mm ring and a 10 mm lobulated lesion. The 256-grid, 64-view operator has 20925 rows and rank 20527; measurements use the finer simulation described in § 17.

CT detection controls

The Gaussian posterior has detection comparable to stochastic AnchoredFM (difference +2.1 points [−0.1, +5.5]), trails deterministic AnchoredFM by about 6–11 Det5 points across exact and sample-based tests, and has worse lesion RMSE and whole-image SSIM than cFM and AnchoredFM (Table S1). In the stochastic CT128 control on part 1, increasing four anchored ensembles from 16 to 64 samples raises sensitivity from 48–50% to 55–59%.

Structural fidelity

SSIM [S2] compares the ensemble mean with truth before display windowing, in native image units. It uses valid 11×1111 \times11 Gaussian windows (standard deviation 1.5 pixels), K1=0.01K_1 = 0.01, K2=0.03K_2 = 0.03, and each true image’s maximum-minus-minimum range. Whole-image values average all parts 1–3 slices, with paired patient-bootstrap comparisons in Table S1 and Table S4 and a noise diagnostic in Table S20.

CT on the 128 grid

Settings transfer to CT256 from part 0 of the 128 grid (2 mm pixels). Table S2 reports the 64-/256-view stochastic comparisons, including DPS and Π\PiGDM. The adverse data-step reconstruction results use the CT128 noise convention in Sec. S7.2.

Brain MRI and photoacoustics

Deterministic MRI fidelity and analytic held coverage are reported in Table S4 and Table S5. Table S3 and Table S6 report lesion-pixel coverage for the secondary stochastic MRI and PAT comparisons. Practical detection uses the reference protocol of § 18.

Tumor exposure in BraTS training

This secondary stochastic control trains separate models with tumors in 66% of training slices, keeping training-set size, patient pool, flips, readings, selection surrogate and sampler settings fixed. Exposure improves unread-component recovery and generally reduces the additional contrast benefit of anchoring. At four-times nominal noise, anchoring increases tumor RMSE for all four tested samplers despite better pixel coverage (Table S7). Tumor contrast is mask mean minus the surrounding four-pixel-ring mean. Unread recovery is the pooled coefficient inner product with the true change, relative to mask-imprinted references, divided by the true change’s pooled squared norm. At nominal noise with the exposed prior, AnchoredFM’s contrast change is −1.5 points [−2.0, −1.0] and its tumor RMSE rises by 0.5% of median brain intensity (Table S7).

Table S7. Stochastic-anchoring robustness comparison: training on slices with tumors in the 64-line BraTS test. Noise standard deviation σ\sigma is relative to median brain intensity. Contrast changes are in percentage points, with paired 95% patient-bootstrap intervals. Exposure is tumor-exposed minus tumor-free for the base sampler. The anchoring columns are anchored minus base under the stated prior. Unread recovery of the base sampler is shown before and after tumor exposure, in %. With exposure, tumor RMSE changes are in % of median brain intensity. Coverage of 90% tumor-pixel intervals is shown before and after anchoring. The AnchoredFM row compares it with cFM.

σ\sigmaSamplerExposureAnchor, tumor-freeAnchor, exposedUnread recoveryΔ\Delta tumor RMSECov.
0.088DDRM+2.4 [1.9, 2.8]+1.4 [1.1, 1.7]+1.0 [0.8, 1.2]59→\to66−0.1 [−0.1, 0.0]67→\to77
DDNM+2.3 [2.0, 2.7]+0.4 [0.3, 0.5]+0.1 [0.0, 0.2]70→\to76+0.2 [0.1, 0.2]72→\to77
ΠGDM+2.4 [2.0, 2.8]0.0 [−0.2, 0.1]−0.2 [−0.3, 0.0]68→\to74+0.1 [0.1, 0.1]74→\to76
Posterior-DDIM+2.4 [2.0, 2.8]+0.6 [0.4, 0.7]+0.1 [0.0, 0.3]67→\to74+0.1 [0.0, 0.1]58→\to64
cFM+5.0 [4.2, 5.9]+2.7 [2.3, 3.2]+1.4 [1.1, 1.6]57→\to72−0.7 [−0.9, −0.5]78→\to82
AnchoredFM+5.0 [4.2, 5.9]+1.5 [0.9, 2.0]−1.5 [−2.0, −1.0]57→\to72+0.5 [0.2, 0.9]78→\to80
0.352DDRM+5.8 [5.0, 6.6]+5.9 [4.8, 7.1]+2.4 [1.8, 3.1]42→\to50+0.7 [0.6, 0.8]55→\to74
DDNM+4.0 [3.5, 4.5]+1.8 [1.3, 2.3]+0.2 [−0.2, 0.6]55→\to63+0.4 [0.2, 0.6]62→\to74
ΠGDM+6.5 [5.5, 7.5]+5.9 [4.6, 7.3]+1.9 [1.2, 2.6]47→\to55+0.6 [0.5, 0.7]68→\to79
Posterior-DDIM+5.9 [5.2, 6.5]+4.9 [4.1, 5.7]+1.2 [0.7, 1.7]51→\to59+0.3 [0.3, 0.4]48→\to69

Table S7.

Acquisition noise in BraTS

The tumor-free-prior stochastic sweep scales the same Gaussian draw per slice at 1, 2, 4 and 8 times nominal noise, with the true level supplied to each sampler. Base settings and κ\kappa minimize tumor RMSE on part 0 and are frozen for testing; wrappers retain base settings. This secondary sweep uses independently selected P-DDIM settings with implicit default η0\eta_0. Table S8 gives the nominal and eight-times endpoints. All four samplers gain contrast at eight-times noise after Holm adjustment, with larger gains than at nominal noise; DDRM’s contrast gain grows from nominal to eight-times noise by 8.7 points [7.4, 9.9]. At eight-times noise tumor RMSE falls for all four, while normal-tissue RMSE rises for three. Coverage improves but remains below 90%.

Detection controls and robustness

FROC protocol. FROC uses threshold-normalized score maps. Candidate marks are 3×33 \times3 local maxima, retained in descending score order up to 32 per image. After each mark, candidates within a center-to-center distance of 16 mm (CT), 8 mm (PAT) or 32 mm (MRI) are suppressed; these are radii of the exclusion discs. Truth components widened by the original localization tolerance define lesions. Greedy one-to-one matching counts unmatched and duplicate marks as false positives. Sensitivity is matched lesions divided by all lesions; burden is false marks per evaluated image, or selected 2D slice in MRI, not per 3D scan.

MRI tables report 0.25 marks per slice; CT and PAT curves span 0.125–2 marks per image. Intervals use 2000 paired patient or anatomy bootstrap draws (Figure S1).

CT and PAT FROC curves

Figure S1. CT and PAT FROC curves. Deterministic CT scores include analytic held variance (§ 9.3): AnchoredFM and six wrappers for CT256, AnchoredFM, cFM and EDM for CT128. PAT shows stochastic anchoring. Bands are 95% patient-bootstrap (CT) or anatomy-bootstrap (PAT) intervals; burdens are per evaluated image.

Sensitivity by lesion size

Every run uses one global FROC threshold across size groups. The primary deterministic checkerboard results are in Table 2 and Table S19; the eight-sampler gain at 64 lines is 8.8 points at 0.25 false marks per slice, with low absolute sensitivity for the smallest tumors.

EDM’s overall interval and several per-group intervals, including the smallest-group intervals for cFM, EDM, DiffPIR and P-DDIM, include zero (Table S19).

Photoacoustic operator error

In this stochastic failure control, the 128-grid reconstruction operator cannot reproduce skin and vessel detail in 256-grid simulated slabs. Operator error is about ten times the assumed noise, and anchoring worsens lesion reconstruction for all three samplers. Simulating on the reconstruction grid reduces the mismatch. The main 256-grid experiment instead simulates with four-times denser per-pixel quadrature; its operator error is one fifth of the noise.

Noise misspecification

Four stochastic CT128 samplers at 64 views use validation-F1 settings and shared data-step readings. With dimensionless assumed-noise multiplier qσ>0q_\sigma> 0, the wrapper selects ri/qσ2>κr_i/q_\sigma^2 > \kappa and adds qσσηjq_\sigma\sigma\eta_j; AnchoredFM keeps its trained held set and scales the perturbation. Other steps retain the true noise. At qσ=0.8q_\sigma= 0.8, healthy FA rises to 13.1–18.2% and F1 changes by −4 to −1 points; at qσ=1.2q_\sigma= 1.2, FA falls and F1 changes by −6 to −5 points. Matched-rate sensitivity changes by at most 1.5 points. Separately, the CT256 resid-

ual outside the range of AA estimates noise at 1.048 times truth, with 90% of images in 0.97–1.13.

AnchoredFM ablation

The same network without a stochastic draw and without analytic held variance flags 99% of healthy CT256 images (Table S10). The comparison with deterministic anchoring using analytic held variance appears in Table S11.

Table S10. Ablations of stochastic AnchoredFM in CT on the 256 grid, 64 views, parts 1–3, in %: the same network without the noise draw and without analytic held variance, compared at AnchoredFM’s κ\kappa; cFM with and without the anchoring wrapper. Where shown, bold (italic) marks better (worse) paired results than AnchoredFM; unmarked entries have no reported significance designation.

64 views
Cov.F1FA
AnchoredFM85.656.01.7
no draw78.429.699.3
cFM + anchoring82.856.82.6
cFM69.725.848.6

Table S10.

Samplerdeterministic, sample var. F1deterministic, sample var. FAdeterministic, sample var. Det5_5deterministic + analytic var. F1deterministic + analytic var. FAdeterministic + analytic var. Det5_5stochastic anchoring F1stochastic anchoring FAstochastic anchoring Det5_5stochastic + analytic var. F1stochastic + analytic var. FAstochastic + analytic var. Det5_5
cFM30.399.947.462.17.166.856.82.657.249.321.562.1
EDM29.999.750.164.84.466.957.81.959.252.616.163.1
DDRM27.798.553.461.56.865.656.22.255.535.845.456.3
DDNM27.297.452.565.23.666.357.01.757.235.447.457.0
DiffPIR27.297.852.965.21.965.653.71.556.551.116.159.0
P-DDIM28.098.654.464.33.265.554.01.756.243.528.257.5
AnchoredFM29.699.351.562.86.066.656.01.757.352.715.761.8

Table S11. CT on the 256 grid, 64 views, parts 1–3: deterministic anchoring (every sample holds lift(yy)) and stochastic anchoring, with held variance estimated from samples or supplied analytically as τ2\tau^2. F1, false alarms and Det5_5 in %. Where shown, bold (italic) marks better (worse) paired results than deterministic anchoring + analytic variance, Holm-adjusted over samplers; unmarked entries have no reported significance designation.

Held directions of the operators

The information-ratio spectra in Figure S2 show how many singular directions each cutoff selects across CT, MRI and PAT.

Figure S2. Information ratio rir_i, in decreasing order, with cutoffs κ=1,3,10,30\kappa= 1, 3, 10, 30.

Anchoring variants and reference controls

Held uncertainty treatments

Table S11 compares deterministic and stochastic anchoring with sample-estimated or analytic held variance under common settings. The analytic correction changes the detector, not reconstructed means or free components. Without it, cFM, EDM and AnchoredFM flag 99–100% of healthy slices; with it, they flag 4–7% and obtain higher Det5_5 than stochastic anchoring. For the four data-step samplers, deterministic FA is 1.9–6.8% and Det5_5 65.5–66.3%, versus stochastic Det5_5 55.5–57.2%. DDRM’s deterministic FA is 6.8% [5.0,8.8], at or above the 5% target. Adding analytic held variance to stochastic anchoring gives 16–47% FA. Unresolved-component uncertainty remains empirical.

As a simpler control, healthy-validation spread rescaling (Table S9) gives base CT FA of 3–7%; it does not consistently meet 5%, alter ranking, or establish coverage at other thresholds. Held-only stochastic null scores agree with t15t_{15} (Figure S3); mixed scores depend on free uncertainty as in § 9.3.

Table S9. CT calibration controls at 64 views: each entry is median preset FA / Det5_5 (%) across samplers with or without an explicit measurement update. Healthy-part-0 spread rescaling changes preset alarms but leaves ranking and Det5_5 unchanged. Deterministic anchoring includes analytic held variance. Gaussian and ideal controls use the same exact healthy reference.

Base samplerBaseRescaledDet. + var.StochasticGaussianIdeal
No data step40/346/346/672/583/551/76
Data step89/586/583/662/563/551/76

Table S9.

Figure S3. Secondary stochastic CT diagnostic. Left: held-template score quantiles versus t15t_{15}. Right: exceedance of the per-position 1% cutoff c=Ft15−1(0.995)c = F^{-1}_{t_{15}}(0.995) versus free variance share ρ\rho, with the Gaussian diagnostic’s predictions (lines) and empirical rates (markers). Markers: star, AnchoredFM; circle, cFM; square, EDM; diamond, DDRM; pentagon, DDNM; hexagon, DiffPIR; cross, P-DDIM.

Data updates from remaining readings

Original network conditioning is retained, including images computed from all readings. Additional data steps constrain the free component using AΠ=QAA\Pi= QA, where Q=Im−UHUHT∈Rm×mQ = I_m - U_{\mathcal{H}}U_{\mathcal{H}}^{\mathsf{T}} \in\mathbb{R}^{m\times m} projects measurements onto the remaining directions.

Data steps use shared QyQy or per-sample Q(y+σηj)Q(y+\sigma\eta_j), with ηj∼N(0,Im)\eta_j \sim\mathcal{N}(0,I_m) independent of acquisition noise and across samples. CT256 uses per-sample readings for both anchor variants at noise level 2σ\sqrt{2}\sigma, accounting for acquisition and added noise. MRI, PAT and supplementary CT IGDM use

shared readings; CT128 retains assumed σ\sigma.

Stochastic CT128 validation gives DDRM and DDNM healthy FA of 28–100% for shared readings versus 0–8% for per-sample readings across cutoffs. CT256 transfers κ=10\kappa= 10 for cFM, EDM and AnchoredFM, and κ=30\kappa= 30 for the four data-step samplers, with healthy-part-0 FA of 1.7–2.5% and 0.4–2.5%, respectively.

Using σ\sigma for perturbed CT256 readings raises DDRM and DDNM median body RMSE from 56–73 to 110–137 HU. Using 2σ\sqrt{2}\sigma gives 56 and 70 HU, with stochastic data-step FA of 1.5–2.2% on parts 1–3. This noise correction is empirical for approximate samplers.

Reference misregistration

The stochastic CT control displaces the same healthy reference for every sampler using white noise smoothed at 20 mm standard deviation and scaled to a specified root-mean-square (RMS) shift. At 0.5 mm, Det5_5 remains 53.1–56.3% with FA 2.1–4.7%; at 1 mm the ranges are 43.3–47.1% and 15.0–23.2%; at 2 mm they are 26.5–29.9% and 75.3–84.0%. Reference error can therefore dominate preserved reconstruction evidence.

Reference-free KLIP control

The KLIP detection adaptation [27] (Tab. S12) uses DPS with the same unconditional prior, measurements, operators and 16 samples. The detection procedure is reimplemented with our shared prior. Its 1000-step variance-preserving (VP) readout squares each likelihood update before averaging, following the paper’s denoising diffusion probabilistic model (DDPM) convention; released CT code averages before squaring. Anchored MRI includes both the held anchor correction and free-direction DPS guidance.

Labeled part 0 selects guidance, block size and scoring window by Det5_5, with AUROC breaking ties; healthy part 0 fixes the 95th-percentile threshold. Held-out Det5_5 recomputes the healthy-test cutoff within each of 2000 paired patient-bootstrap draws; part-0 selection is not resampled. KLIP selects MRI guidance 1, while subtraction DPS selects 3, so these are separately tuned pipelines.

Deterministic MRI KLIP gains are +10.0 AUROC points [7.2,13.1] and +16.2 Det5_5 points [5.9,25.1]. The

TestTest/patientsValidationSettingAUROCDet5_5FAval_{\mathrm{val}}
MRI, 64 lines661/701; 60491/211, 2, 25–45%83.7 [80.2,87.0]55.1 [45.8,63.9]6.7 [3.5,10.8]
+ deterministic661/701; 60491/211, 8, 75–80%93.7 [91.7,95.5]71.2 [59.6,79.1]4.9 [2.2,8.3]
CT, 64 views1080/720; 45600/1530, 8, 80–100%70.5 [67.6,73.6]32.8 [28.2,36.8]4.9 [3.2,6.7]
PAT, 64 detectors78/78; 2750/930, 16, 35–40%62.4 [54.8,68.3]0.0 [0.0,2.6]6.4 [1.4,12.3]

Table S12. KLIP adaptation, with deterministic MRI anchoring at κ=30\kappa= 30. Test counts are anomalous and healthy images; validation counts are images and patients. Settings give guidance, block side and VP scoring-window fraction. Metrics and patient-bootstrap 95% intervals are in %; FA uses the validation-frozen threshold.

stochastic counterpart gives 93.8% AUROC, 71.2% Det5_5 and 4.6% FA. With checkerboard seed 0, subtraction DPS gives 75.4% AUROC and 23.3% Det5_5; deterministic anchoring gives 83.7% and 45.4%, a within-pipeline Det5_5 gain of 22.1 points [14.1,28.4]. Both subtraction Det5_5 estimates remain below unanchored KLIP, with no reported paired cross-pipeline interval. CT and PAT subtraction additionally accesses an exact healthy reference. Reference availability and tuning differ between these pipelines. MRI and CT base KLIP, PAT KLIP and anchored MRI KLIP ran on different GPUs (L40S, H200 and H100), precluding a wall-clock comparison.

Numerical implementation

CT and PAT compute a dense-operator singular value decomposition (SVD) once in double precision. MRI uses orthonormal Hartley rows, with U=ImU = I_m and si=1s_i = 1. Each prior variance viTCviv_i^{\mathsf{T}} C v_i uses one stationary-covariance FFT product. The surrogate measures broad normal-image variability, not anatomical knowledge; degenerate singular subspaces can give solver-dependent held bases, so matched dense-operator experiments use the same GPU type (excluding the KLIP control). Networks run in single precision and projections in double precision. With T≥1T \ge1 Euler steps, AnchoredFM updates x←x+T−1Πvθ(x,n/T,x^(y))x \leftarrow x + T^{-1}\Pi_{v_\theta}(x,n/T,\hat{x}(y)) for n=0,…,T−1n = 0,\ldots,T - 1; its distinction between training and inference is given in Sec. S1.

AnchoredFM runtime and quality

The stochastic CT runtime study (Table S13) uses one H100, the 128 grid, 64 views and 16 samples on 432 lesion images from 45 test patients. Contrast error is absolute departure from full lesion recovery; coverage error is departure of mean lesion-pixel coverage from 90%. The reported trade-off is not monotonic in every metric, and anchored cFM has lower lesion RMSE than one-step AnchoredFM. Times are median repeated, GPU-synchronized reconstruction calls after network and operator setup and warm-up; setup and training are excluded.

SamplerNFETime (s)Lesion RMSEContrast err.Coverage err.
AnchoredFM10.0058965.526.89.4
AnchoredFM20.010365.326.89.3
AnchoredFM50.023665.626.86.5
AnchoredFM100.045765.827.02.5
AnchoredFM200.089866.527.01.1
AnchoredFM1000.44167.327.14.1
cFM + anchoring10.0050659.328.618.4
cFM + anchoring20.0094259.328.519.5
cFM + anchoring50.022559.328.316.7
cFM + anchoring100.04459.527.912.2
cFM + anchoring200.087859.727.97.5
cFM + anchoring1000.43660.127.92.5
cFM1000.41162.948.426.4
DDRM + anchoring1000.58273.929.50.0
DDNM + anchoring1991.55127.732.414.3
DPS + anchoring10009.8368.128.75.3
Π\PiGDM + anchoring10019.581.926.12.5
DiffPIR + anchoring10005.8675.026.13.2
P-DDIM + anchoring1000.58371.326.82.8
EDM + anchoring350.71767.927.53.2
Gaussian posterior00.001261.028.84.8

Table S13. Stochastic CT128 runtime and quality: the AnchoredFM and anchored-cFM budgets plotted in the main paper, full-budget learned comparators, and the Gaussian control. NFE is the number of network evaluations per sample; time is in seconds per 16-sample ensemble. RMSE is in HU, contrast error in %, and coverage error in percentage points.

Experimental setup details

Acquisitions. All acquisitions are simulated; detection models train on normal images. CT uses LoDoPaB-CT chest slices [37], a 256 grid with 1 mm pixels, 64 parallel-beam views, and Gaussian noise at 1% of the median central reading. Lesions are specified in Sec. S5.2; additional tests use the 128 grid at 64/256 views. Readings are simulated from 362-grid images with a finer projector than reconstruction. Brain Tumor Segmentation (BraTS)/Medical Segmentation Decathlon (MSD) fluid-attenuated inversion recovery (FLAIR) MRI [38] uses 256-grid, 1 mm images at 32/64 of 256 k-space lines (8/4×44\times4 acceleration), noise of a 1 mm scan, and released real tumors with expert masks. Training uses tumor-free slices of training patients. Virtual Imaging Clinical Trials for Regulatory Evaluation (VICTRE)-family PAT [39, 40] uses 256-grid breast phantoms with 0.66 mm pixels, initial pressure at 800 nm, 64 ring detectors and matched healthy twins.

Selection and statistics. All methods return 16 samples. MRI has eight paired base and anchored samplers; main CT256 has six, with DPS and NIGDM in CT128; PAT has cFM, DPS and DDNM. cFM and EDM condition on the surrogate MAP image, while data-step methods share an unconditional prior. Patient part 0 selects settings, with parts 1–3 held out. Base settings minimize lesion error in MRI and PAT and maximize preset F1 in CT; anchored pairs retain them. MRI and PAT select κ\kappa by labeled lesion error. CT selects the largest κ∈{1,3,10,30}\kappa\in\{1,3,10,30\} with at most 5% healthy-validation FA, or the fewest FA if none qualifies, then transfers settings from 128 to 256 grid. All stochastic CT256 variants remain within 5% on healthy part 0. Table marks use paired bootstrap p<0.05p < 0.05, Holm-adjusted across sampler pairs; text intervals are unadjusted. Practical MRI inference follows § 18.

Controls. The direct measurement statistic is T(p)=⟨Awp,y−Ar⟩/(σ∥Awp∥)T(p) = \langle A_{w_p},y - Ar\rangle/(\sigma\lVert A_{w_p}\rVert) for p∈Pp \in\mathcal{P} with ∥Awp∥>0\lVert A_{w_p}\rVert> 0, using the same Bonferroni family. It is optimal for a known healthy reference, template and position under the Gaussian model. Gaussian-surrogate posterior samples use Matheron’s rule [47, 48], with an additional exact-covariance test. Spread rescaling fits one factor per base sampler on healthy part 0 and freezes it for testing. KLIP’s separately tuned adaptation is in § 14.4.

Data and ethics. All experiments use existing public resources: LoDoPaB-CT [37], the BraTS FLAIR data distributed with the Medical Segmentation Decathlon [38], and computer-generated breast phantoms [39, 40]. We collected no new data from human participants and had no access to identifying information, so no institutional review was sought for this secondary analysis. Approval and consent for the original acquisitions are described by the dataset providers [37, 38]. All measurements are simulated, and the method has not been validated for clinical use.

MRI references and detection protocol

Checkerboard reference. On the normalized 256-by-256, 1 mm grid, the zero-filled inverse Hartley image initializes the minimization of

12∥AVxTV−y∥2+0.05∑u,v(DxxTV)u,v2+(DyxTV)u,v2+0.0122\frac{1}{2}\lVert A_Vx_{\mathrm{TV}}-y\rVert^2 + 0.05\sum_{u,v}\sqrt{(D_xx_{\mathrm{TV}})_{u,v}^2+(D_yx_{\mathrm{TV}})_{u,v}^2+0.012^2}

using 400 double-precision Adam [S3] steps at learning rate 0.02 and default moments. Here V∈{32,64}V \in\{32,64\} counts acquired MRI lines, xTVx_{\mathrm{TV}} is the candidate image, and AV∈R256V×2562A_V \in\mathbb{R}^{256V \times256^2} is the main operator AA for that Hartley-line acquisition, with measurements y∈R256Vy \in\mathbb{R}^{256V}. Indices u,v∈{0,…,255}u,v \in\{0,\ldots,255\} denote row and column. Dx,DyD_x,D_y take forward column and row differences, respectively, with zero differences at the last column or row; the norm is Euclidean. This procedure is applied separately to each measurement setting (noise 0.088) to obtain its initial context.

The grid is partitioned into 16-by-16 squares. The first mask has even ⌊u/16⌋+⌊v/16⌋\lfloor u/16\rfloor+\lfloor v/16\rfloor; the second is its complement. Each of 16 draws inpaints the first mask with the tumor-free unconditional flow prior, then the second using the first-pass output as context. Each pass starts from fresh standard normal noise ξ\xi and takes 100 Euler steps at t=0,0.01,…,0.99t=0,0.01,\ldots,0.99. Before each velocity evaluation, unmasked pixels are set to (1−t)ξ+txctx(1-t)\xi+tx_{\mathrm{ctx}}, where xctxx_{\mathrm{ctx}} is that pass’s context. The state updates by xt+0.01←xt+0.01vθ(xt,t)x_{t+0.01}\leftarrow x_t+0.01v_\theta(x_t,t), and the unmasked context is restored exactly at the end. The second pass retains generated first-pass squares. Networks use single precision and state updates double precision.

The mean of 16 second-pass images is the fixed reference shared by all reconstruction samplers. Reference construction uses neither tumor masks nor a tumor finder and treats tumor and healthy slices identically. Results average ten reference seeds (0–9).

Oracle control. The oracle reference averages 16 flow in-paintings of the true image inside the expert tumor mask dilated by square radius 16 pixels. A healthy slice is its own reference. This privileged reference nearly saturates AUROC and Det5_5 even without anchoring; scores also respond to changes in healthy surroundings. FROC additionally counts false marks on tumor slices.

Cohort and settings. Part 0 has 491 slices from 21 patients (252 healthy); parts 1–3 have 1362 slices from 60 patients (661 tumor, 701 healthy). Primary comparisons use eight matched samplers with P-DDIM η0=0\eta_0 = 0, η1=16\eta_1 = 16 across base, deterministic and stochastic treatments. AnchoredFM is compared separately with cFM and excluded from eight-sampler means.

Scores and inference. Scores use reconstruction variance times 1+1/K1 + 1/K, K=16K = 16, plus analytic τ2\tau^2 for deterministic anchoring. Reference error remains in the residual. Templates are 8, 16 and 32 mm discs. The common evaluation mask is derived from skull-stripped truth by thresholding at 0.15, filling holes, eroding four times with cross connectivity, and excluding a four-pixel square neighborhood of the exterior. Each absolute score is normalized by the two-sided Bonferroni t15t_{15} threshold over tested position–size pairs. Null laws for mixed templates and estimated references remain approximate.

For each sampler and treatment, the 95th-percentile multiplier is fitted to pooled healthy-validation scores over ten reference seeds and frozen for test parts 1–3. The unadjusted Bonferroni rule flags all healthy checkerboard test slices and is not used as a calibrated operating point. Det5_5 instead uses a retrospective healthy-test cutoff; AUROC ranks global scores. Partial AUC averages localized sensitivity over 201 rates from 0 to 5% FA. MRI AUROC and slice sensitivity average four predefined tumor-size classes; FROC averages lesions.

Intervals use 2000 paired bootstrap draws of the 60 test patients, with reference seeds resampled within each replicate and shared draws across samplers. Point estimates average ten seeds, with validation thresholds fixed throughout the test bootstrap. Intervals are exploratory and unadjusted. Global spread rescaling changes score scale and preset alarms, not ranking or reconstruction samples.

Checkerboard results

Deterministic anchoring raises mean frozen-threshold sensitivity from 20.2% to 44.1% with FA 3.2% and 3.3%; matched stochastic anchoring reaches 37.6% sensitivity. Table S16, Table S17 and Table S19 provide treatment means, deterministic paired changes and lesion-size results. The deterministic oracle control is reported in Table S18. EDM’s three overall stochastic intervals and several per-group intervals, including the smallest-group cFM and EDM intervals, include zero (Table S14 and Table S15).

SamplerΔ\Delta AUROCΔ\Delta Sens.val_{\mathrm{val}}Δ\Delta [email protected]
cFM+4.2 [+2.1, +6.2]+19.1 [+15.6, +22.8]+4.5 [+2.1, +6.8]
EDM+0.9 [-0.4, +2.3]-1.1 [-3.6, +1.2]-0.5 [-2.5, +1.6]
DPS+6.8 [+5.3, +8.4]+15.6 [+12.1, +18.8]+8.4 [+5.4, +11.5]
Π\PiGDM+3.8 [+2.5, +5.2]+15.7 [+12.1, +19.4]+3.4 [+1.0, +5.9]
DDRM+6.1 [+4.6, +7.7]+21.3 [+17.2, +25.6]+6.1 [+3.6, +8.3]
DDNM+13.3 [+11.3, +15.5]+35.7 [+29.8, +41.6]+15.4 [+11.8, +18.8]
DiffPIR+3.8 [+2.6, +5.0]+7.8 [+4.9, +10.9]+2.7 [+0.3, +5.0]
P-DDIM+15.1 [+12.6, +17.7]+35.4 [+29.3, +41.6]+18.8 [+14.3, +23.3]
AnchoredFM+4.3 [+2.2, +6.4]+22.2 [+18.5, +25.9]+6.1 [+3.8, +8.4]
Eight-sampler mean+6.8 [+5.8, +7.8]+18.7 [+15.6, +21.7]+7.3 [+5.5, +9.2]

Table S14. Stochastic checkerboard MRI comparison at 64 lines with default P-DDIM η0\eta_0: stochastic anchoring minus the matched base sampler, in percentage points with paired patient and seed bootstrap 95% intervals. AnchoredFM is compared with cFM. These exploratory intervals are not multiplicity-adjusted.

Sampler11–23 mm23–34 mm34–45 mm≥45\ge45 mmAll
cFM9.134.855.872.740.8
+ anchoring9.438.865.776.745.3
difference+0.4 [-2.7, +3.6]+4.0 [-0.6, +8.9]+9.9 [+4.6, +15.1]+4.0 [+0.3, +8.1]+4.5 [+2.1, +6.8]
EDM10.338.365.178.545.6
+ anchoring8.737.168.476.145.1
difference-1.6 [-4.4, +1.7]-1.2 [-5.9, +3.7]+3.3 [-0.0, +6.8]-2.4 [-5.5, +0.8]-0.5 [-2.5, +1.6]
DPS5.126.950.265.034.6
+ anchoring7.736.262.175.543.0
difference+2.7 [-0.0, +5.3]+9.3 [+4.7, +14.3]+11.9 [+6.8, +17.1]+10.4 [+4.5, +17.2]+8.4 [+5.4, +11.5]
Π\PiGDM6.132.961.076.941.7
+ anchoring10.536.065.777.845.0
difference+4.4 [+1.6, +7.4]+3.1 [-2.0, +8.4]+4.7 [+0.8, +9.1]+0.8 [-3.2, +5.6]+3.4 [+1.0, +5.9]
DDRM6.427.154.474.838.1
+ anchoring8.837.664.575.344.2
difference+2.4 [-1.0, +5.5]+10.5 [+5.6, +15.1]+10.1 [+4.9, +15.7]+0.4 [-3.9, +4.6]+6.1 [+3.6, +8.3]
DDNM4.420.040.958.829.0
+ anchoring9.237.963.776.144.4
difference+4.7 [+1.5, +7.7]+17.9 [+12.4, +23.3]+22.8 [+15.8, +29.2]+17.3 [+9.4, +25.1]+15.4 [+11.8, +18.8]
DiffPIR8.530.862.575.141.7
+ anchoring8.836.866.375.644.5
difference+0.3 [-2.1, +2.6]+6.0 [+1.2, +10.2]+3.8 [-1.1, +8.9]+0.5 [-4.0, +4.9]+2.7 [+0.3, +5.0]
P-DDIM2.713.736.159.325.7
+ anchoring9.038.162.978.044.6
difference+6.3 [+2.9, +10.3]+24.4 [+17.9, +29.9]+26.8 [+17.9, +38.2]+18.7 [+11.2, +26.1]+18.8 [+14.3, +23.3]
cFM9.134.855.872.740.8
AnchoredFM11.240.867.177.946.9
difference+2.2 [-1.0, +5.7]+6.0 [+1.4, +10.1]+11.3 [+5.9, +16.5]+5.3 [+1.1, +10.1]+6.1 [+3.8, +8.4]
Eight-sampler mean6.628.153.370.237.2
+ anchoring9.037.364.976.444.5
difference+2.5 [+0.9, +4.9]+9.2 [+6.3, +12.1]+11.7 [+8.3, +15.4]+6.2 [+3.0, +9.3]+7.3 [+5.5, +9.2]

Table S15. Stochastic checkerboard MRI comparison at 64 lines with default P-DDIM η0\eta_0: lesion sensitivity (%) at 0.25 false-positive marks per slice, by predefined tumor size. Each run uses one global threshold across groups. Base, stochastic anchoring, and their paired differences are averaged over ten reference seeds. Differences are in points with paired patient and seed bootstrap 95% intervals. The separate cFM–AnchoredFM comparison is excluded from the eight-sampler mean.

The stochastic-minus-base difference in EDM’s frozen-threshold sensitivity at 32 lines is −3.8 points [-6.5, −1.1] (Table S17).

Qualitative examples and diagnostic checks

The selected lesion examples (Figure S4) show detections gained through preserved contrast; healthy examples show false alarms removed. They also illustrate lower global SSIM despite better lesion decisions.

Figure S4. Truth and 16-sample means at 64 MRI lines, CT views or PAT detectors. MRI and CT use deterministic anchoring (κ=1\kappa= 1 and 10, respectively); PAT uses stochastic anchoring (κ=30\kappa= 30). Green outlines show lesions; cyan boxes give matched lesion or healthy-score-maximum zooms. Within each case, display windows and zooms are identical. SSIM precedes display windowing. Contrast is tumor-to-ring recovery in MRI or true lesion-profile recovery against the exact healthy reference in CT and PAT. Scores are threshold-normalized maxima near the lesion (support plus four pixels) or over healthy search positions; s>1s > 1 flags a detection or alarm. MRI thresholds are healthy-validation-frozen over ten seeds; CT and PAT use preset Bonferroni thresholds over position–template pairs. Deterministic scores include analytic held variance.

Selection. All examples compare Gaussian posterior, cFM and anchored cFM with 16 samples; Gaussian results do not enter selection. MRI uses checkerboard seed 0. Among tumors detected only after anchoring with lower SSIM and contrast error, selection takes median unanchored contrast recovery. Among removed healthy alarms with lower SSIM and all original flags inside brain tissue, it takes median unanchored score. CT follows Sec. S5.1. PAT takes median unanchored score among cases with gained lesion detections or removed healthy alarms with lower SSIM, requiring improved lesion contrast. Even-sized sets use the upper middle case.

Supplementary references

[S1] Hongkai Zheng, Wenda Chu, Bingliang Zhang, Zhihui Wu, Austin Wang, Berthy T. Feng, Caifeng Zou, Yu Sun, Nikola Kovachki, Zachary E. Ross, Katherine L. Bouman, and Yisong Yue. InverseBench: Benchmarking Plug-and-Play Diffusion Priors for Inverse Problems in Physical Sciences. In International Conference on Learning Representations, 2025.

[S2] Zhou Wang, Alan C. Bovik, Hamid R. Sheikh, and Eero P. Simoncelli. Image Quality Assessment: From Error Visibility to Structural Similarity. IEEE Transactions on Image Processing, 13(4):600–612, 2004.

[S3] Diederik P. Kingma and Jimmy Ba. Adam: A Method for Stochastic Optimization. In International Conference on Learning Representations, 2015.

References

  1. [1]Hyungjin Chung, Jeongsol Kim, Michael T. McCann, Marc L. Klasky, and Jong Chul Ye. Diffusion posterior sampling for general noisy inverse problems. In International Conference on Learning Representations (ICLR), 2023. URL https://openreview.net/forum?id=OnD9zGAGT0k. arXiv:2209.14687. 2, 3, 5arxiv.org/abs/2209.14687
  2. [2]Bahjat Kawar, Michael Elad, Stefano Ermon, and Jiaming Song. Denoising diffusion restoration models. In Advances in Neural Information Processing Systems (NeurIPS), volume 35, pages 23593–23606, 2022. doi: 10.52202/068431-1714. arXiv:2201.11793. 3, 5DOI
  3. [3]Yang Song, Liyue Shen, Lei Xing, and Stefano Ermon. Solving inverse problems in medical imaging with score-based generative models. In International Conference on Learning Representations (ICLR), 2022. URL https://openreview.net/forum?id=vaRCHVj0uGI. arXiv:2111.08005. 2, 3arxiv.org/abs/2111.08005
  4. [4]Sayantan Bhadra, Yuran A. Kelkar, Frank J. Brooks, and Mark A. Anastasio. On hallucinations in tomographic image reconstruction. IEEE Transactions on Medical Imaging, 40(11):3249–3260, 2021. doi: 10.1109/TMI.2021.3077857. arXiv:2012.00646. 2DOI
  5. [5]Thomas Schlegl, Philipp Seeböck, Sebastian M. Waldstein, Georg Langs, and Ursula Schmidt-Erfurth. f-AnoGAN: Fast unsupervised anomaly detection with generative adversarial networks. Medical Image Analysis, 54:30–44, 2019. doi: 10.1016/j.media.2019.01.010. 2DOI
  6. [6]Julian Wyatt, Adam Leach, Sebastian M. Schmon, and Chris G. Willcocks. AnoDDPM: Anomaly detection with denoising diffusion probabilistic models using simplex noise. In IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW), pages 649–655, 2022. doi: 10.1109/CVPRW56347.2022.00080. 2DOI
  7. [7]Cosmin I. Bercea, Benedikt Wiestler, Daniel Rueckert, and Julia A. Schnabel. Evaluating normative representation learning in generative AI for robust anomaly detection in brain imaging. Nature Communications, 16(1):1624, 2025. doi: 10.1038/s41467-025-56321-y. 2DOI
  8. [8]Ségolène Martin, Anne Gagneux, Paul Hagemann, and Gabriele Steidl. PnP-Flow: Plug-and-play image restoration with flow matching. In International Conference on Learning Representations (ICLR), pages 45466–45492, 2025. URL https://openreview.net/forum?id=5AtHrq3B5R. arXiv:2410.02423. 2, 3arxiv.org/abs/2410.02423
  9. [9]Yinhui Wang, Jiwen Yu, and Jian Zhang. Zero-shot image restoration using denoising diffusion null-space model. In International Conference on Learning Representations (ICLR), 2023. URL https://openreview.net/forum?id=mRieQgMtNTQ. arXiv:2212.00490. 2, 3, 5arxiv.org/abs/2212.00490
  10. [10]Junhyeok Lee and Kyu Sung Choi. Measured-subspace consistency: A plug-and-play operator for diffusion posterior sampling in accelerated MRI reconstruction. arXiv preprint arXiv:2606.28448, 2026. 3arxiv.org/abs/2606.28448
  11. [11]Xiao Shi, Edward P. Chandler, Chicago Y. Park, Shirin Shoushtari, and Ulugbek S. Kamilov. NullFlow: One-step generative reconstruction. arXiv preprint arXiv:2606.22696, 2026. 2, 3arxiv.org/abs/2606.22696
  12. [12]Yaron Lipman, Ricky T. Q. Chen, Heli Ben-Hamu, Maximilian Nickel, and Mattias Le. Flow matching for generative modeling. In International Conference on Learning Representations (ICLR), 2023. URL https://openreview.net/forum?id=PqvMRDCUT9t. arXiv:2210.02747. 2, 4, 5arxiv.org/abs/2210.02747
  13. [13]Christoph Baur, Stefan Denner, Benedikt Wiestler, Nassir Navab, and Shadi Albarqouni. Autoencoders for unsupervised anomaly segmentation in brain MR images: A comparative study. Medical Image Analysis, 69:101952, 2021. doi: 10.1016/j.media.2020.101952. arXiv:2004.03271. 2DOI
  14. [14]Walter H. L. Pinaya, Mark S. Graham, Robert Gray, Pedro F. da Costa, Petru-Daniel Tudosiua, Paul Wright, Yee H. Mah, Andrew D. MacKinnon, James T. Teo, Rolf Jager, David Werring, Geraint Rees, Parashkev Nachev, Sebastien Ourselin, and M. Jorge Cardoso. Fast unsupervised brain anomaly detection and segmentation with diffusion models. In Medical Image Computing and Computer-Assisted Intervention (MICCAI), Lecture Notes in Computer Science, pages 705–714. Springer, 2022. doi: 10.1007/978-3-031-16452-1_67. arXiv:2206.03461. 2 detail: Uncovering clinically relevant image details in accelerated MRI with semantically diverse reconstructions. In Medical Image Computing and Computer-Assisted Intervention (MICCAI), Lecture Notes in Computer Science, pages 356–366. Springer, 2025. doi: 10.1007/978-3-032-04937-7_34. arXiv:2507.00670. 3DOI
  15. [15]Julia Wolleb, Florentin Bieder, Robin Sandkühler, and Philippe C. Cattin. Diffusion models for medical anomaly detection. In Medical Image Computing and Computer-Assisted Intervention (MICCAI), Lecture Notes in Computer Science, pages 35–45. Springer, 2022. doi: 10.1007/978-3-031-16452-1_4. arXiv:2203.04306.DOI
  16. [16]Cosmin I. Bercea, Benedikt Wiestler, Daniel Rueckert, and Julia A. Schnabel. Diffusion models with implicit guidance for medical anomaly detection. In Medical Image Computing and Computer-Assisted Intervention (MICCAI), Lecture Notes in Computer Science, pages 211–220. Springer, 2024. doi: 10.1007/978-3-031-72120-5_20. arXiv:2403.08464. 2DOI
  17. [17]Vitjan Zavrtanik, Matej Kristan, and Danijel Skočaj. DRÆM – a discriminatively trained reconstruction embedding for surface anomaly detection. In IEEE/CVF International Conference on Computer Vision (ICCV), pages 8310–8319, 2021. doi: 10.1109/ICCV48922.2021.00822. arXiv:2108.07610. 2DOI
  18. [18]Karsten Roth, Latha Pemula, Joaquin Zepeda, Bernhard Schölkopf, Thomas Brox, and Peter Gehler. Towards total recall in industrial anomaly detection. In IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR), pages 14298–14308, 2022. doi: 10.1109/CVPR52688.2022.01392. 2DOI
  19. [19]Jia Guo, Shuai Lu, Weihang Zhang, Fang Chen, Huiqi Li, and Hongen Liao. Dinomaly: The less is more philosophy in multi-class unsupervised anomaly detection. In IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR), pages 20405–20415, 2025. doi: 10.1109/CVPR52734.2025.01900. arXiv:2405.14325. 2DOI
  20. [20]Kaiyang Cheng, Francesco Calivá, Rutwik Shah, Misung Han, Sharmila Majumdar, and Valentina Pedaia. Addressing the false negative problem of deep learning MRI reconstruction models by adversarial attacks and robust training. In Medical Imaging with Deep Learning (MIDL), volume 121 of Proceedings of Machine Learning Research, pages 121–135. PMLR, 2020. URL https://proceedings.mlr.press/v121/cheng20a.html. 3
  21. [21]Quintin van Lohuizen, Christian Roest, Frank F. J. Simonis, Stefan J. Fransen, Thomas C. Kwee, Derya Yakar, and Henk-Jan Huisman. Assessing deep learning reconstruction for faster prostate MRI: visual vs. diagnostic performance metrics. European Radiology, 34(11):7364–7372, 2024. doi: 10.1007/s00330-024-10771-y. 8DOI
  22. [22]Corey T. Jensen, Shiva Gupta, Mohammed M. Saleh, Xinming Liu, Vincenzo K. Wong, Usama Salem, Wei Qiao, Ehsan Samei, and Nicolaus A. Wagner-Bartak. Reduced-dose deep learning reconstruction for abdominal CT of liver metastases. Radiology, 303(1):90–98, 2022. doi: 10.1148/radiol.211838. 3, 8DOI
  23. [23]Jan Nikolas Morshuis, Christian Schlar­mann, Thomas Küstner, Christian F. Baumgartner, and Matthias Hein. Mind the detail: Uncovering clinically relevant image details in accelerated MRI with semantically diverse reconstructions. In Medical Image Computing and Computer-Assisted Intervention (MICCAI), Lecture Notes in Computer Science, pages 356–366. Springer, 2025. doi: 10.1007/978-3-032-04937-7_34. arXiv:2507.00670. 3
  24. [24]Namhoon Kim and Sara Fridovich-Keil. Towards distribution-shift uncertainty estimation for inverse problems with generative priors. In IEEE International Workshop on Computational Advances in Multi-Sensor Adaptive Processing (CAMSAP), pages 291–295, 2025. doi: 10.1109/CAMSAP66162.2025.11423986. arXiv:2510.10947. 3DOI
  25. [25]Ezgi Demircan-Tureyen, Felix Lucka, and Tristan van Leeuwen. Exploring out-of-distribution detection for sparse-view computed tomography with diffusion models. Scientific Reports, 16(1):36003, 2026. doi: 10.1038/s41598-026-70507-4. arXiv:2411.06308.
  26. [26]Tom Sprunck, Marcelo Pereyra, and Tobías I. Liaudat. Bayesian model selection and misspecification testing in imaging inverse problems only from noisy and partial measurements. In Proceedings of the 43rd International Conference on Machine Learning, volume 306 of Proceedings of Machine Learning Research, pages 115394–115419. PMLR, 2026. URL https://proceedings.mlr.press/v306/sprunck26a.html. arXiv:2510.27663.arxiv.org/abs/2510.27663
  27. [27]Alireza Kheirandish, Jihoon Hong, and Sara Fridovich-Keil. KLIP: Localized distribution shift detection via KL-divergence with diffusion priors in inverse problems. In IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR), pages 30823–30832, 2026. URL https://openaccess.thecvf.com/content/CVPR2026/html/Kheirandish_KLIP_Localized_Distribution_Shift_Detection_via_KL-Divergence_with_Diffusion_Priors_CVPR_2026_paper.html. arXiv:2605.31956. 3, 5, 7, S9arxiv.org/abs/2605.31596
  28. [28]Johannes Schwab, Stephan Antholzer, Robert Nuster, Günther Paltauf, and Markus Haltmeier. Deep learning of truncated singular values for limited view photoacoustic tomography. arXiv preprint arXiv:1901.06498, 2019. 3arxiv.org/abs/1901.06498
  29. [29]Bahjat Kawar, Gregory Vaksman, and Michael Elad. SNIPS: Solving noisy inverse problems stochastically. In Advances in Neural Information Processing Systems (NeurIPS), volume 34, pages 21757–21769, 2021. URL https://proceedings.neurips.cc/paper_files/paper/2021/hash/b5c501503401b70d41d8e03deb31bd8c-Abstract.html. arXiv:2105.14951. 3arxiv.org/abs/2105.14951
  30. [30]Zehao Dou and Yang Song. Diffusion posterior sampling for linear inverse problem solving: A filtering perspective. In International Conference on Learning Representations (ICLR), pages 12069–12095, 2024. URL https://openreview.net/forum?id=tp1XNChZs1. 3
  31. [31]Anastasios N. Angelopoulos, Amit P. Kohli, Stephen Bates, Michael I. Jordan, Jitendra Malik, Thayer Al-Shaabi, Srigokul Upadhyaya, and Yaniv Romano. Image-to-Image Regression with Distribution-Free Uncertainty Quantification and Applications in Imaging. In Proceedings of the 39th International Conference on Machine Learning, volume 162 of Proceedings of Machine Learning Research, pages 717–730. PMLR, 2022. URL https://proceedings.mlr.press/v162/angelopoulos22a.html. arXiv:2202.05265. 3
  32. [32]Jacopo Teneggi, Matthew Tivnan, J. Webster Stayman, and Jeremias Sulam. How to Trust Your Diffusion Model: A Convex Optimization Approach to Conformal Risk Control. In Proceedings of the 40th International Conference on Machine Learning, volume 202 of Proceedings of Machine Learning Research, pages 33940–33960. PMLR, 2023. URL https://proceedings.mlr.press/v202/teneggi23a.html. arXiv:2302.03791. 3arxiv.org/abs/2302.03791
  33. [33]Gerrit Burgers, Peter Jan van Leeuwen, and Geir Evensen. Analysis Scheme in the Ensemble Kalman Filter. Monthly Weather Review, 126(6):1719–1724, 1998. doi: 10.1175/1520-0493(1998)126<1719:ASITEK>2.0.CO;2. 3doi.org/10.1175/1520-0493(1998)126<1719:asitek>2.0.co;2
  34. [34]Johnathan M. Bardsley, Antti Solonen, Heikki Haario, and Marko Laine. Randomize-Then-Optimize: A Method for Sampling from Posterior Distributions in Nonlinear Inverse Problems. SIAM Journal on Scientific Computing, 36(4):A1895–A1910, 2014. doi: 10.1137/140964023. 3DOI
  35. [35]Yuchen Jiao, Na Li, Changxiao Cai, Yuxin Chen, and Gen Li. Provable diffusion-based posterior sampling for linear inverse problems via DDIM. arXiv preprint arXiv:2607.19333, 2026. 3, 5arxiv.org/abs/2607.19333
  36. [36]Xingchao Liu, Chengyue Gong, and Qiang Liu. Flow straight and fast: Learning to generate and transfer data with rectified flow. In International Conference on Learning Representations (ICLR), 2023. URL https://openreview.net/forum?id=XVjT1nW5z. arXiv:2209.03003. 4arxiv.org/abs/2209.03003
  37. [37]Johannes Leuschner, Maximilian Schmidt, Daniel Otero Baguer, and Peter Maass. LoDoPaB-CT, a benchmark dataset for low-dose computed tomography reconstruction. Scientific Data, 8(1):109, 2021. doi: 10.1038/s41597-021-00893-z. arXiv:1910.01113. 5, S10, S11DOI
  38. [38]Michela Antonelli, Annika Reinke, Spyridon Bakas, Keyvan Farahani, Annette Kopp-Schneider, et al. The Medical Segmentation Decathlon. Nature Communications, 13(1):4128, 2022. doi: 10.1038/s41467-022-30695-9. arXiv:2106.05735. 5, S10, S11DOI
  39. [39]Seonyeong Park, Gangwon Jeong, Umberto Villa, and Mark A. Anastasio. A virtual imaging framework for three-dimensional quantitative optoacoustic tomography using stochastic numerical breast phantoms. Photoacoustics, 51:100850, 2026. doi: 10.1016/j.pacs.2026.100850. arXiv:2510.00189. 5, S10, S11DOI
  40. [40]Aldo Briano, Christian G. Graff, Andreu Badal, Diksha Sharma, Rongping Zeng, Frank W. Samuelson, Stephen J. Glick, and Kyle J. Myers. Evaluation of digital breast tomosynthesis as replacement of full-field digital mammography using an in silico imaging trial. JAMA Network Open, 1(7):e185474, 2018. doi: 10.1001/jamanetworkopen.2018.5474. 5, S10, S11
  41. [41]Tero Karras, Miika Aittala, Timo Aila, and Samuli Laine. Elucidating the design space of diffusion-based generative models. In Advances in Neural Information Processing Systems (NeurIPS), volume 35, pages 26565–26577, 2022. doi: 10.52202/068431-1926. arXiv:2206.00364. 5DOI
  42. [42]Jiaming Song, Arash Vahdat, Morteza Mardani, and Jan Kautz. Pseudoinverse-guided diffusion models for inverse problems. In International Conference on Learning Representations (ICLR), 2023. URL https://openreview.net/forum?id=9_gsMA8MRKQ. 5
  43. [43]Yuanzhi Zhu, Kai Zhang, Jingyun Liang, Jiezhang Cao, Bihan Wen, Radu Timofte, and Luc Van Gool. Denoising diffusion models for plug-and-play image restoration. In IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW), pages 1219–1229, 2023. doi: 10.1109/CVPRW59228.2023.00129. arXiv:2305.08995. 5DOI
  44. [44]Efrat Shimron, Jonathan I. Tamir, Ke Wang, and Michael Lustig. Implicit data crimes: Machine learning bias arising from misuse of public data. Proceedings of the National Academy of Sciences, 119(13):e2117203119, 2022. doi: 10.1073/pnas.2117203119. arXiv:2109.08237. 8
  45. [45]Tiangang Cui, James Martin, Youssef M. Marzouk, Antti Solonen, and Alessio Spantini. Likelihood-informed dimension reduction for nonlinear inverse problems. Inverse Problems, 30(11):114015, 2014. doi: 10.1088/0266-5611/30/11/114015. arXiv:1403.4680. S1DOI
  46. [46]Alessio Spantini, Antti Solonen, Tiangang Cui, James Martin, Luis Tenorio, and Youssef Marzouk. Optimal low-rank approximations of Bayesian linear inverse problems. SIAM Journal on Scientific Computing, 37(6):A2451–A2487, 2015. doi: 10.1137/140977308. arXiv:1407.3463. S1DOI
  47. [47]Yehuda Hoffman and Erez Ribak. Constrained Realizations of Gaussian Fields: A Simple Algorithm. The Astrophysical Journal, 380(1):L5–L8, 1991. doi: 10.1086/186160. S10DOI
  48. [48]James T. Wilson, Viacheslav Borovitskiy, Alexander Terenin, Peter Mostowsky, and Marc Peter Deisenroth. Efficiently Sampling Functions from Gaussian Process Posteriors. In Proceedings of the 37th International Conference on Machine Learning, volume 119 of Proceedings of Machine Learning Research, pages 10292–10302. PMLR, 2020. URL https://proceedings.mlr.press/v119/wilson20a.html. arXiv:2002.09309. S10arxiv.org/abs/2002.09309

Paper details

vlnc:W_yrwyuj7a
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 0

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Computer Science

Claude Code, ChatGPT, Codex

View statement
Looking for related papers…
Contents