A study of neutrinoless double electron capture in 40^{40}Ca from the AMoRE experiment

Abstract

The search for neutrinoless double electron capture (0ν2EC0ν\mathrm{2EC}) provides a sensitive probe of lepton-number violation and the Majorana nature of neutrinos. We investigate the 0ν2EC0ν\mathrm{2EC} decay of 40^{40}Ca using cryogenic detectors equipped with metallic magnetic calorimeters in the AMoRE-I experiment. The analysis is based on a physics dataset corresponding to a total exposure of 7.32 kg⋅\cdotyr from thirteen 40^{40}Ca100^{100}MoO4_4 crystals. No significant excess is observed, and a lower limit on the half-life is obtained as T1/20ν>1.7×1022T^{0ν}_{1/2} > 1.7 \times 10^{22} yr at 90%\% confidence level. An improved sensitivity is expected for the upcoming AMoRE-II experiment. These results demonstrate the potential of CaMoO4_4 detectors to explore rare decay processes beyond the primary 100^{100}Mo 0νββ0νββ search program.

^1 Address(es) of author(s) should be given

Introduction

Electron capture (EC) is a weak-interaction process in which a bound atomic electron, typically from the innermost K or L shells, is absorbed by the nucleus, converting a proton into a neutron with the emission of an electron neutrino. The subsequent atomic relaxation produces characteristic X-rays and Auger electrons that serve as experimental signatures [1]. In some triplets, where the energy of the intermediate nucleus is higher and prevents single electron capture, two such captures can occur simultaneously, giving rise to double electron capture (2ν2EC2\nu2\mathrm{EC}), a second-order weak process that has been directly observed in 124Xe^{124}\mathrm{Xe} [2, 3, 4], indicated in geochemical studies of 130Ba^{130}\mathrm{Ba} [5, 6], and also in 78Kr^{78}\mathrm{Kr} [7, 8] by using proportional counter. The hypothetical neutrinoless variant (0ν2EC0\nu2\mathrm{EC}) would proceed without neutrino emission if neutrinos are Majorana particles, thus violating total lepton number conservation [9, 10, 11]. Since no neutrinos are emitted, the observable signatures of 0ν2EC0\nu2\mathrm{EC} arise from the atomic de-excitation of the daughter atom producing X-rays and Auger electrons, as well as from the emission of at least one particle to conserve energy–momentum in the transition [12, 13]. Different types of the emission of particles can be considered such as e−e+e^-e^+ pairs, one or two real photons, or one internal conversion electron (IC). The probability of 0ν2EC0\nu2\mathrm{EC} decay process is extremely low, but can be enhanced significantly when the decay is nearly resonant—that is, when the energy released by the nuclear transition closely matches the sum of the binding energies of the captured electrons and the excitation energy of the daughter atom [9, 12]. This resonant 0ν2EC0\nu2\mathrm{EC} can shorten the half-life by many orders of magnitude, making only a handful of isotopes (such as 152Gd{}^{152}\mathrm{Gd}, 164Er{}^{164}\mathrm{Er}, and 180W{}^{180}\mathrm{W}) promising candidates for current searches [9, 10, 11, 12, 14]. The discovery of 0ν2EC0\nu2\mathrm{EC} would not only provide direct evidence for the Majorana nature of neutrinos but also contribute to understanding the absolute neutrino mass scale and the matter–antimatter asymmetry in the Universe [9, 10, 12, 13], providing a complementary research avenue to neutrinoless double beta (0νββ0\nu\beta\beta) decay.

AMoRE is an underground experiment for the investigation of extremely rare nuclear decays with cryogenic calorimeters. The experiment makes use of scintillating crystals, operated at millikelvin temperatures, in association with metallic magnetic calorimeters for the simultaneous readout of phonon and photon signals [15, 16, 17]. The dual-readout scheme enables particle identification to effectively reject backgrounds due to α\alpha decays [17, 18]. The latest phase, AMoRE-I, has been successfully completed, demonstrating the long-term stability of the detection system for about 3 years with an upgraded setup comprising thirteen 40Ca100MoO4{}^{40}\mathrm{Ca}^{100}\mathrm{MoO}_4 (CMO) and five Li2100MoO4\mathrm{Li}_2{}^{100}\mathrm{MoO}_4 (LMO) scintillating crystals [17].

Though the primary physics goal of AMoRE is the search for 0νββ0\nu\beta\beta decay of 100Mo{}^{100}\mathrm{Mo}, the CMO crystals also contain 40Ca{}^{40}\mathrm{Ca} as a naturally occurring isotope. This makes the experiment also well-suited to search for 0ν2EC0\nu2\mathrm{EC} of 40Ca{}^{40}\mathrm{Ca}, an especially promising candidate, considering a very high isotopic concentration in the natural isotopic admixture δ=96.941(156)%\delta= 96.941(156)\% [19]. The decay energy for 40Ca{}^{40}\mathrm{Ca} 0ν2EC0\nu2\mathrm{EC} is Q2EC=193.50(2)Q_{2\mathrm{EC}} = 193.50(2) keV [20], disfavoring the possible resonant enhancement process in 40Ca{}^{40}\mathrm{Ca} isotope [11]. An experimental investigation for 0ν2EC0\nu2\mathrm{EC} signature of 40Ca{}^{40}\mathrm{Ca} has been previously performed by the CRESST collaboration using CaWO4_4 bolometers [21]. The experiment set the half-life limit of T1/20ν>1.4×1022T^{0\nu}_{1/2} > 1.4 \times10^{22} yr at 90% confidence level (CL). We here present the experimental investigation of 0ν2EC0\nu2\mathrm{EC} of 40Ca{}^{40}\mathrm{Ca} based on the AMoRE-I data, using total exposure of 7.32 kg·yr, corresponding to the 40Ca{}^{40}\mathrm{Ca} isotopic exposure of 1.43 kg·yr.

Experiment and Data analysis

The AMoRE-I experiment was conducted during the period between December 2020 and May 2023 at the Yangyang Underground Laboratory, located at a depth of about 700 meters of rock overburden. Detailed descriptions of the experimental setup and detector design are presented in the previous AMoRE-I publications [17, 22]. The entire AMoRE-I data have been reanalyzed—including the event trigger for lowering the energy threshold [23], adoption of the optimal filtering for the signal amplitude determination, corrections for signal instabilities, and the energy calibration. While details of the analysis are provided in Ref. [24], we briefly describe the energy-scale reconstruction here.

The energy calibration was performed in two steps. In the first step, amplitudes (AA) divided by their true energy values (EE) for four prominent peaks at 583, 911, 969, and 2615 keV of γ\gamma-rays in the 232Th{}^{232}\mathrm{Th} source are calibrated using a linear function of energy (A/E=p0+p1EA/E = p_0 + p_1E). In the second step, an additional low energy 75 keV Pb X-ray peak was included together with these γ\gamma-ray energies to refine the calibration with addition of an exponential term to the linear function, i.e. A/E=p0′+p1′E+p2exp⁡(−p3E)A/E = p'_0 + p'_1E + p_2\exp(-p_3E). Further details on the signal analysis and calibration can be found in the Ref. [24].

Due to non-uniform, position-dependent detector response, energy peaks occurred in most of detectors displayed asymmetric shapes with tails on the low- and high-energy sides. Among the different tested peak fitting functions the optimal fit was provided by the Bukin function [25], which accounted for the asymmetric nature of all peaks in the calibration spectra. The full width at half maximum (FWHM) energy resolution (ΔEFWHM≈2.355σ\Delta E_{\mathrm{FWHM}} \approx2.355\sigma) was modeled using a function ΔEFWHM2=q0+q1E+q2E2\Delta E_{\mathrm{FWHM}}^2 = q_0 + q_1E + q_2E^2 [26], to determine the value and its uncertainty at the 0ν2EC0\nu2\mathrm{EC} region of interest (ROI).

The response of each detector module exhibited a discontinuous shift after an unexpected power outage occurred in November 2021. Therefore, we divided the data into two groups. The period from December 2020 until November 2021 is referred to as the before-power-outage (BPO) dataset, while the period from January 2022 to May 2023 is the after-power-outage (APO) dataset. Interestingly, the energy resolution improved significantly over most of detectors after the power outage, although the underlying cause of this change remains unclear. In addition, a detector module (CMO 03 in Table 1) unresponsive during the BPO period started to work after the power outage. The FWHM energy resolutions for all CMO crystal detectors in the two datasets are shown in Table 1, with most detectors exhibiting resolutions of about 2.5 to 4 keV FWHM at 0ν2EC0\nu2\mathrm{EC} ROI for APO dataset. Other shape parameters like asymmetry (ξ\xi), left-tail (ρl\rho_l) and right-tail (ρr\rho_r) [25], which are obtained by fitting the calibration peaks, showed weak dependence on energy, and their uncertainties were interpolated using a linear or exponential function based on detector’s characteristics to determine the signal shape at ROI.

Detector module indexm⋅tm \cdot t (10−310^{-3} kg·yr) BPOm⋅tm \cdot t (10−310^{-3} kg·yr) APOΔEFWHM\Delta E_{\mathrm{FWHM}} (keV) BPOΔEFWHM\Delta E_{\mathrm{FWHM}} (keV) APObb (count/keV/kg/day) BPObb (count/keV/kg/day) APO
012323845.84.57.46.1
022323562.92.57.95.4
03–342–5.3–5.7
042353622.92.68.45.7
05*1692583.42.659.854.7
062323025.06.58.55.7
072814283.33.09.17.5
082303593.83.38.55.6
092333563.22.78.46.2
101261973.32.910.26.5
113114736.03.67.15.3
122463754.23.28.86.1
132363604.33.08.66.2
Total / Average73163.49.7

Table 1. Summary of mass-time exposure (m⋅tm \cdot t), full-width-half-maximum energy resolution (ΔEFWHM\Delta E_{\mathrm{FWHM}}), and background index (bb) in the ROI for the AMoRE-I CMO crystal detectors in the BPO and APO datasets. Uncertainty of ΔEFWHM\Delta E_{\mathrm{FWHM}} is typically at a few-percent level. The higher background in the BPO dataset is attributed to temporary aluminum plates in the shielding supporting structure, later found to be contaminated with 228Ra{}^{228}\mathrm{Ra} and removed [17]. Detector modules indexes are for the CMO detectors only, listed with their masses in Ref. [22].

Basic data-quality conditions were applied to eliminate non-physical events such as heater pulses and SQUID reset signals [24]. To suppress backgrounds from cosmic-ray interactions and multi-site energy depositions, coincident events in other detector channels or in the external muon veto system were rejected. The muon detector registered about ten thousand muon candidates per day [17], and the resulting coincidence cut within a 3 ms window reduced the efficiency by less than 0.1%, with negligible associated uncertainty. In addition, a single-hit requirement was imposed: only events with no additional signal at other detector module within a 3 ms time window were retained. Given the typical trigger rate of ∼1\sim1 Hz during physics runs, this selection achieved an event selection efficiency of approximately 99.8%. The typical trigger threshold was around 20 keV for most detectors, well below the ROI near 193.5 keV for 40Ca{}^{40}\mathrm{Ca} 0ν2EC0\nu2\mathrm{EC}. Figure 1 shows an energy spectrum of the detector CMO 02 for APO dataset where we can observe low energetic γ\gamma line/IC, X-rays, and nuclear recoil signature.

Background spectrum of the CMO 02 APO dataset

Figure 1. Background spectrum of the CMO 02 APO dataset. The peak around 50 keV originates from the beta decay of 210Pb{}^{210}\mathrm{Pb}, which consists of 46.5 keV IC/Auger electrons and γ\gamma/X-rays together with about 4 keV mean energy deposition from β\beta electrons [27, 28]. From left to right, distinct features are observed: the Pb Kα_\alpha doublet near 75 keV, the Kβ_\beta triplet around 85 keV [29], and a peak at ∼\sim100 keV associated with the nuclear recoil of 206Pb{}^{206}\mathrm{Pb} following the 210Po{}^{210}\mathrm{Po} alpha decay with 5304 keV emission [27]. The dashed red line represents the Q2ECQ_{2\mathrm{EC}} value of 0ν2EC0\nu2\mathrm{EC} decay process.

The 0ν2EC0\nu2\mathrm{EC} process in 40Ca{}^{40}\mathrm{Ca} can proceed through distinct atomic capture processes depending on the shells of the captured electrons. The dominant capture probabilities are fKK≃85%f_{\mathrm{KK}} \simeq85\%, fLL≃1%f_{\mathrm{LL}} \simeq1\% [21], with the remaining fKL≃14%f_{\mathrm{KL}} \simeq14\% inferred to complete the total capture probability.

For a ground- to ground-state transition, the emission of a single real photon is forbidden in the KK capture channel by angular momentum conservation [13]. While double-photon emission is kinematically allowed, it remains highly suppressed as a second-order electromagnetic process, scaling with an additional factor of the fine-structure constant

and subject to a reduced phase-space volume. Consequently, the transition proceeds predominantly via IC, in which a virtual photon is absorbed by an atomic electron, resulting in the emission of an IC electron. In contrast, both single real photon emission and IC are allowed for KL capture.

The full-energy absorption efficiency was evaluated using GEANT4 Monte Carlo simulations [30], incorporating the realistic detector geometry and material properties of the CMO crystals. For each decay channel, the total available energy is given by the QQ-value of transition and is redistributed according to the binding energies of the captured electrons. In all channels, atomic vacancies created by electron capture lead to the emission of X-rays and Auger electrons during atomic relaxation. Since these particles deposit their energy locally in the crystal, the total observable energy corresponds to the QQ value of the decay, resulting in a mono-energetic peak.

Three representative channels were simulated: (i) KK capture with an IC electron, (ii) KL capture with a real photon, and (iii) KL capture with an IC electron. For the IC channels, most of the emitted electrons deposit their full energy in the detector, resulting in the detection efficiencies close to unity, i.e., εIC≈1\varepsilon^{\mathrm{IC}} \approx1. In contrast, the KL photon channel shows a lower full-energy absorption efficiency, εKLγ≈0.47\varepsilon^{\gamma}_{\mathrm{KL}} \approx0.47–0.570.57, depending on the crystal mass (196–473 g). This reflects the reduced photon interaction probability in CMO crystals (density 4.34 g/cm3^3) compared with CaWO4_4 (6.06 g/cm3^3) crystals used in CRESST-II [21].

The containment detection efficiency (εcont\varepsilon_{\mathrm{cont}}) is obtained by weighting the individual detection efficiencies by the corresponding capture probabilities,

εcont=fKKεKKIC+fKL(rγεKLγ+rICεKLIC),(1)\varepsilon_{\mathrm{cont}} = f_{\mathrm{KK}}\varepsilon^{\mathrm{IC}}_{\mathrm{KK}} + f_{\mathrm{KL}}\left(r_{\gamma}\varepsilon^{\gamma}_{\mathrm{KL}} + r_{\mathrm{IC}}\varepsilon^{\mathrm{IC}}_{\mathrm{KL}}\right), \tag*{(1)}

where rγr_{\gamma} and rIC(=1−rγ)r_{\mathrm{IC}} (=1-r_{\gamma}) denote the branching fractions for photon emission and IC in the KL capture channel, respectively. We assumed rγ=1r_{\gamma}=1 to conservatively determine half-life, as the exact ratio between rγr_{\gamma} and rICr_{\mathrm{IC}} remains undetermined. The resulting overall containment detection efficiency for the CMO crystals is found to lie in the range εcont=0.91\varepsilon_{\mathrm{cont}} = 0.91–0.930.93.

The total detection efficiency (ε\varepsilon) for the 0ν2EC0\nu2\mathrm{EC} signature is obtained by combining the containment efficiency with the anti-coincidence survival efficiency and the trigger efficiency. The trigger efficiency at the ROI is unity for all detectors except for 0.93 for the noisiest CMO 01 detector. Taking these factors into account for each detector, the resulting detection efficiency is estimated to be ε≈0.86\varepsilon\approx0.86–0.920.92.

Limit on the 0ν2EC0\nu2\mathrm{EC} half-life of 40Ca{}^{40}\mathrm{Ca}

The search for the 40Ca{}^{40}\mathrm{Ca} 0ν2EC0\nu2\mathrm{EC} decay was performed by fitting the energy spectra in a ±12σ\pm12\sigma energy window around the expected signal peak at Q2EC=193.5Q_{2\mathrm{EC}} = 193.5 keV. The energy spectrum of the ii’th dataset is modeled as the sum of background components (BiB_i) and an expected 0ν2EC0\nu2\mathrm{EC} signal (SiS_i). BiB_i consist of a slowly varying part described by a linear function of energy (BilinB_i^{\mathrm{lin}}), superimposed with a small peak at 186 keV (BipeakB_i^{\mathrm{peak}}) which is primarily attributed to the decay of 226Ra{}^{226}\mathrm{Ra} with a possible contribution from the decay of 235U{}^{235}\mathrm{U} [31]. The expected signal is expressed as:

Si(Γ,E;θi)=εiΓηmiNAMCMOtiP(E;θi),(2)S_i(\Gamma,E;\theta_i) = \varepsilon_i\Gamma\frac{\eta m_i N_A}{M_{\mathrm{CMO}}}t_iP(E;\theta_i), \tag*{(2)}

where εi\varepsilon_i denote the total detection efficiency, Γ\Gamma is the 0ν2EC0\nu2\mathrm{EC} decay rate, η\eta is the abundance of 40Ca{}^{40}\mathrm{Ca} in the CMO crystal (η∼99.95%\eta\sim99.95\%) [32], NAN_A is Avogadro’s number, mim_i is the crystal mass, tit_i is the live time, and MCMOM_{\mathrm{CMO}} is the molar mass of CMO compound. The function P(E;θi)P(E;\theta_i) denotes the Bukin probability density function (p.d.f.) describing the detector response [25], where θi\theta_i is the set of the function parameters consisting of the peak location and the shape parameters such as the resolution, asymmetry, left-tail and right-tail. BipeakB_i^{\mathrm{peak}} is also represented using the Bukin function sharing same values of the shape parameters with SiS_i, because the locations of the two peaks are very close. The shape parameters and the peak locations were subject to Gaussian constraints, whose widths (Δθi\Delta\theta_i) were derived in the energy calibration process.

We then construct a binned-extended likelihood L\mathcal{L} combining the above probability density functions and constraints:

L=∏iLi(Γ,μi;θi)=∏i[∏jμijnije−μijnij!]e−(θi−⟨θi′⟩)22(Δθi′)2,(3)\mathcal{L} = \prod_i \mathcal{L}_i(\Gamma,\mu_i;\theta_i) = \prod_i \left[\prod_j \frac{\mu_{ij}^{n_{ij}}e^{-\mu_{ij}}}{n_{ij}!}\right]e^{-\frac{(\theta_i-\langle\theta_i'\rangle)^2}{2(\Delta\theta_i')^2}}, \tag*{(3)}

where nijn_{ij} is the observed event number in the jj’th energy bin of the ii’th dataset, μij\mu_{ij} is the expected event number consisting of the total number of events and the model p.d.f. with the energy bin width ΔE=0.5\Delta E=0.5 keV:

μij=μi[fiBi(Ej)+(1−fi)Si(Ej)]ΔE,(4)\mu_{ij} = \mu_i\left[f_iB_i(E_j)+(1-f_i)S_i(E_j)\right]\Delta E, \tag*{(4)}

and the last exponent term accounts for the Gaussian constraints for systematic uncertainties regarding all efficiencies and peak function parameters, with the mean values ⟨θi′⟩\langle\theta_i'\rangle and widths Δθi′\Delta\theta_i'. The fitting was performed using the IMINUIT software [33], to calculate the minimized negative logarithms of L\mathcal{L} in (3) along the Γ\Gamma values from 0 to the sensitive range at around 10−2110^{-21} yr−1^{-1}.

Results and Discussions

Figure 2 shows the fitting result as the profile likelihood divided with its maximum value at Γbest∼1.2×10−23\Gamma_{\mathrm{best}} \sim1.2 \times10^{-23} yr−1^{-1}. This non-zero value of Γbest\Gamma_{\mathrm{best}} does not signal evidence for a 0ν2EC0\nu2\mathrm{EC} signature; rather, it reflects statistical fluctuations in the background within the ROI. Figure 3 displays the best-fit including signal and background model for combined datasets. The upper limit on Γ\Gamma, or the lower limit on the 0ν2EC0\nu2\mathrm{EC} half-life (T1/20νT_{1/2}^{0\nu}) at 90% CL is obtained from the likelihood profile by interpreting

Normalized likelihood function and normalized integration relative to the decay rate

Figure 2. The normalized likelihood function and its normalized integration with relative to the decay rate Γ0ν\Gamma^{0\nu}. The blue solid line represents the profile likelihood and orange solid line is the cumulative distribution function. The green dashed line displays the limit corresponding to 90% CL.

Combined energy spectrum of all 13 CMO detectors

Figure 3. A combined energy spectrum of all 13 CMO detectors with best fit (red curve) of the signal-plus-background model. The 90% CL limit is also shown by green curve. The peak around 186 keV is attributed to unresolved γ\gamma-ray background contributions, as discussed in the text.

ΓCL=ln⁡2/T1/20ν>∫0ΓCLL dΓ∫0∞L dΓ,(5)\Gamma_{\mathrm{CL}} = \ln2/T_{1/2}^{0\nu} > \frac{\int_0^{\Gamma_{\mathrm{CL}}}\mathcal{L}\,\mathrm{d}\Gamma}{\int_0^{\infty}\mathcal{L}\,\mathrm{d}\Gamma}, \tag*{(5)}

as shown as the orange curve in Figure 2. As a result, we obtained a 90% CL upper limit at Γ90=4.1×10−23\Gamma_{90}=4.1 \times10^{-23} yr−1^{-1}, corresponding to a lower limit on the half-life of T1/20ν>1.7×1022T_{1/2}^{0\nu} > 1.7 \times10^{22} yr. This presents stronger constraints for the half-life compared to earlier study reported by CRESST-II experiment using CaWO4_4 crystal [21].

The experimental sensitivity was estimated using pseudo-experiments under the background-only hypothesis. Thousands of pseudo-datasets were generated assuming the background model without a signal contribution. Each pseudo-dataset was then fitted with the same signal-plus-background model used in the data analysis, and the upper limit of the decay rate Γ\Gamma at 90% CL was obtained using the profile likelihood. The median ±\pm 34% exclusion sensitivity obtained from these pseudo-experiments corresponds to a half-life limit of T1/20ν=2.0−0.6+0.8×1022T_{1/2}^{0\nu} = 2.0^{+0.8}_{-0.6} \times10^{22} yr.

As the collaboration prepares for the AMoRE-II experiment, which will soon become operational employing 90 kg of 100{}^{100}Mo, most of the detector array will consist of LMO crystals. However, at least 13 CMO crystals previously used in the AMoRE-I experiment will also be installed in the AMoRE-II setup. Considering dedicated studies for the background reduction, optimized shield configuration [34, 35], and enhanced detector performance [18, 36] for AMoRE-II, significantly lower background level is expected with the new experiment even at the lower energy relevant to 0ν2EC0\nu2\mathrm{EC} in 40{}^{40}Ca. Based on the simulated background level at the ROI, we projected the exclusion sensitivity of AMoRE-II on the 0ν2EC0\nu2\mathrm{EC} decay of 40{}^{40}Ca. The estimate assumes a total CMO detector mass of 4.6 kg (similar to AMoRE-I) and a live time of 5 years, with the energy resolution and detection efficiency obtained in the AMoRE-I experiment. The resulting median ±\pm 34% exclusion sensitivity is T1/20ν∼9−3+4×1022T_{1/2}^{0\nu} \sim9^{+4}_{-3} \times10^{22} yr at 90% CL, representing an improvement of about a factor of five compared to the current AMoRE-I limit. This improvement arises primarily from the expected fivefold reduction in

background levels together with an approximately threefold increase in exposure.

Summary and Conclusions

A search for the 0ν2EC0\nu2\mathrm{EC} decay of 40{}^{40}Ca was performed using the AMoRE-I background dataset, corresponding to a total exposure of 7.32 kg·yr and an isotopic exposure of 1.43 kg·yr in 40{}^{40}Ca. No excess consistent with the signal was observed, and a lower limit on the half-life was set as T1/20ν>1.7×1022T_{1/2}^{0\nu} > 1.7 \times10^{22} yr at 90% CL. This result slightly improves the previous limit reported by the CRESST collaboration.

The present analysis demonstrates that the AMoRE experiment can probe rare processes beyond its primary search for the 0νββ0\nu\beta\beta decay of 100{}^{100}Mo. In particular, CMO crystals provide a promising experimental platform for investigating the 0ν2EC0\nu2\mathrm{EC} decay of 40{}^{40}Ca with competitive sensitivity. In preparation for the AMoRE-II experiment, a sensitivity study was performed assuming a CMO detector mass of 4.6 kg, a live time of 5 years, and the background level obtained from simulations of the improved experimental configuration. Using the energy resolution and detection efficiency estimated in AMoRE-I, the expected median exclusion sensitivity was estimated to be T1/20ν∼9×1022T_{1/2}^{0\nu} \sim9 \times10^{22} yr at 90% CL, representing an improvement of about a factor five compared to the present AMoRE-I limit.

Furthermore, the current AMoRE-I dataset does not reach the sufficiently low energy threshold required to search for the allowed two-neutrino double K-capture (2ν2K2\nu2\mathrm{K}) process in 40{}^{40}Ca, whose expected signature lies at 6.4 keV [29] and which has not yet been observed. However, with the improved detector performance, enhanced noise suppression, and optimized trigger algorithms anticipated for the AMoRE-II experiment, searches for both the 2ν2K2\nu2\mathrm{K} and 0ν2EC0\nu2\mathrm{EC} processes in 40{}^{40}Ca are expected to become feasible with substantially improved sensitivity.

These results highlight the broader physics potential of the AMoRE project, extending from few-keV rare-event searches to MeV-scale probes of physics beyond the Standard Model.

Acknowledgements

Acknowledgements The authors thank Prof. M. I. Krivoruchenko (Laboratory of Elementary Particles Theory, Kurchatov Complex of Theoretical and Experimental Physics, National Research Centre “Kurchatov Institute”, Moscow, Russia) for valuable discussions on the particle emission mechanisms in the 0ν2EC0\nu2\mathrm{EC} process of 40Ca{}^{40}\mathrm{Ca}.

This research was supported by the Institute for Basic Science (IBS) under Grants No. IBS-R016-D1 and No. IBS-R016-A2. Additional support was provided by the National Research Foundation of Korea (NRF) under Grants No. NRF-2021R1I1A3041453 and No. NRF-2021R1A6A1A03043957, and by the National Research Facilities & Equipment Center (NFEC) of Korea under Grant No. 2019R1A6C1010027.

We also acknowledge support from the Ministry of Science and Higher Education of the Russian Federation (Project No. N121031700314-5) and the MEPhI Program Priority 2030.

We thank the Korea Hydro and Nuclear Power (KHNP) Company for providing underground laboratory space at Yangyang and the IBS Research Solution Center (RSC) for providing high-performance computing resources.

These acknowledgments are not to be interpreted as an endorsement of any statement made by the authors by any of the affiliated institutes, funding agencies, governments, or their representatives.

References

  1. [1]W. Bambynek et al., Rev. Mod. Phys. 49, 77–221 (1977). https://doi.org/10.1103/RevModPhys.49.77
  2. [2]E. Aprile et al. (XENON Collaboration), Nature 568, 532–535 (2019). https://doi.org/10.1038/s41586-019-1124-4
  3. [3]J. Aalbers et al. (LZ Collaboration), J. Phys. G: Nucl. Part. Phys. 52, 015103 (2025); Erratum: J. Phys. G: Nucl. Part. Phys. 53, 059601 (2026). https://doi.org/10.1088/1361-6471/ad9039
  4. [4]Z. Bo et al. (PandaX-4T Collaboration), JHEP 05, 119 (2025). https://doi.org/10.1007/JHEP05(2025)119
  5. [5]A.P. Meshik et al., Phys. Rev. C 64, 035205 (2001). https://doi.org/10.1103/PhysRevC.64.035205
  6. [6]M. Pujol et al., Acta 73, 6834–6846 (2009). https://doi.org/10.1016/j.gca.2009.08.002
  7. [7]Yu.M. Gavrilyuk et al., Phys. Rev. C 87, 035501 (2013). https://doi.org/10.1103/PhysRevC.87.035501
  8. [8]S.S. Ratkevich et al., Phys. Rev. C 96, 065502 (2017). https://doi.org/10.1103/PhysRevC.96.065502
  9. [9]J. Bernabéu, A. De Rújula, C. Jarlskog, Nucl. Phys. B 223, 15–28 (1983). https://doi.org/10.1016/0550-3213(83)90089-5
  10. [10]F. Šimković, M.I. Krivoruchenko, A. Faessler, Prog. Part. Nucl. Phys. 66, 446–451 (2011). https://doi.org/10.1016/j.ppnp.2011.01.049
  11. [11]K. Blaum et al., Rev. Mod. Phys. 92, 045007 (2020). https://doi.org/10.1103/RevModPhys.92.045007
  12. [12]F.F. Karpeshin, Phys. Part. Nucl. Lett. 5, 379–382 (2008). https://doi.org/10.1134/S1547477108040080
  13. [13]M. Doi, T. Kotani, Prog. Theor. Phys. 89, 139–159 (1993). https://doi.org/10.1143/ptp/89.1.139
  14. [14]P. Belli et al., J. Phys. G: Nucl. Part. Phys. 53, 045101 (2026). https://doi.org/10.1088/1361-6471/ae4d66
  15. [15]V. Alenkov et al., Eur. Phys. J. C 79, 791 (2019). https://doi.org/10.1140/epjc/s10052-019-7279-1
  16. [16]A. Agrawal et al. (AMoRE Collaboration), Astropart. Phys. 162, 102991 (2024). https://doi.org/10.1016/j.astropartphys.2024.102991
  17. [17]A. Agrawal et al. (AMoRE Collaboration), Phys. Rev. Lett. 134, 082501 (2025). https://doi.org/10.1103/PhysRevLett.134.082501
  18. [18]A. Agrawal et al. (AMoRE Collaboration), Eur. Phys. J. C 85, 172 (2025). https://doi.org/10.1140/epjc/s10052-024-13498-8
  19. [19]J. Mejia et al., Pure Appl. Chem. 88, 293–306 (2016). https://doi.org/10.1515/pac-2015-0503
  20. [20]M. Wang et al., Chin. Phys. C 45, 030003 (2021). https://doi.org/10.1088/1674-1137/abddaf
  21. [21]G. Angloher et al., J. Phys. G: Nucl. Part. Phys. 43, 095202 (2016). https://doi.org/10.1088/0954-3899/43/9/095202
  22. [22]H.B. Kim et al., J. Low Temp. Phys. 209, 962–970 (2022). https://doi.org/10.1007/s10909-022-02880-z
  23. [23]M.A. Bartsch, D.L. Neuhoff, G.H. Wakefield, University of Michigan EECS 206 Laboratory Manual (2003). https://www.eecs.umich.edu/courses/eecs206/public/lab/
  24. [24]A. Agrawal et al. (AMoRE Collaboration), The Development of Analysis Framework for AMoRE Experiment, in preparation.
  25. [25]RooBuKinPdf Class Reference. https://root.cern.ch/doc/master/classRooBuKinPdf.html Accessed 16 September 2025.
  26. [26]C.W. Fabjan, F. Gianotti, Rev. Mod. Phys. 75, 1243–1286 (2003). https://doi.org/10.1103/RevModPhys.75.1243
  27. [27]National Nuclear Data Center, NuDat 3.0 Database, Brookhaven National Laboratory. https://www.nndc.bnl.gov/nudat3/ Accessed March 2026.
  28. [28]G. Adhikari et al. (COSINE-100 Collaboration), Eur. Phys. J. C 81, 837 (2021). https://doi.org/10.1140/epjc/s10052-021-09564-0
  29. [29]A.C. Thompson, D. Vaughan (eds.), X-Ray Data Booklet, 2nd edn. Lawrence Berkeley National Laboratory, Berkeley (2001). https://xdb.lbl.gov/
  30. [30]S. Agostinelli et al., Nucl. Instrum. Methods Phys. Res. A 506, 250–303 (2003). https://doi.org/10.1016/S0168-9002(03)01368-8
  31. [31]V. Alenkov et al. (AMoRE Collaboration), Eur. Phys. J. C 82, 1140 (2022). https://doi.org/10.1140/epjc/s10052- 022-11104-3
  32. [32]S. Karki et al., Nucl. Instrum. Methods Phys. Res. A 877, 328–330 (2018). https://doi.org/10.1016/j.nima.2017.10.007
  33. [33]H. Dembinski et al., scikit-hep/iminuit, Zenodo (2025). https://doi.org/10.5281/zenodo.17565861
  34. [34]A. Agrawal et al. (AMoRE Collaboration), Front. Phys. 12, 1362209 (2024). https://doi.org/10.3389/fphy.2024.1362209
  35. [35]A. Agrawal et al. (AMoRE Collaboration), Eur. Phys. J. C 85, 9 (2025). https://doi.org/10.1140/epjc/s10052-024-13516-9
  36. [36]W.T. Kim et al., JINST 17, P07034 (2022). https://doi.org/10.1088/1748-0221/17/07/P07034

Paper details

vlnc:W_za7rdgaw
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 4

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents