Predicting Activities in Aqueous Electrolyte Solutions with Hybrid Machine Learning

Abstract

Activities in aqueous electrolyte solutions, usually described by ionic activity and osmotic coefficients, are important properties for modeling many processes in industry and nature. Established activity models, such as those of Pitzer or Bromley, require fitting to experimental data for each electrolyte of interest and thus cannot predict properties for unstudied systems. While some predictive approaches exist, they are typically limited in scope and rely on additional ion-specific descriptors. In this work, we introduce a new hybrid model that combines the physics-based Bromley model with a matrix completion method (MCM) from machine learning. The MCM is employed to predict the electrolyte-specific parameters of the Bromley model, exploiting the fact that these parameters can be arranged in a matrix with cations and anions as rows and columns, respectively. Due to the lack of experimental data for many electrolytes, the initial parameter matrix is sparsely populated, making the prediction of the Bromley parameters for unstudied electrolytes a matrix completion problem. The hybrid model, Bromley-MCM, was trained end-to-end on experimental data for mean ionic activity coefficients and osmotic coefficients of aqueous solutions of 478 electrolytes at 298 K from the Dortmund Data Bank. As output, we obtain a completed matrix of Bromley parameters for 83 cations and 112 anions, enabling consistent prediction of concentration-dependent activities in aqueous solutions of 9,296 electrolytes at 298~K. This substantially extends the applicability of the Bromley model while maintaining high predictive accuracy, as demonstrated through evaluations on electrolytes excluded from model training.

main.pdf

Introduction

Activities in electrolyte solutions play an important role in addressing many critical engineering challenges, e.g., electrochemical energy storage [1] and desalination applications. [2] Here, the term ”activities” is used collectively for different properties that essentially describe the chemical potentials of the ions, the electrolyte, and the solvent in electrolyte solutions. Most established experimental methods for determining such properties focus on solvent activity, often expressed as the osmotic coefficient. These approaches include the isopiestic method[?] and the measurement of the vapor pressure, [?] the freezing-point depression, [?] and the osmotic pressure. [?] Having conducted a measurement series with either of these methods, the activity of the electrolyte in solution, usually represented in terms of the mean ionic activity coefficient, can be inferred by evaluating the Gibbs-Duhem equation. A notable direct method for determining the mean ionic activity coefficient is the measurement of open-circuit voltages (formerly also called electromotive force measurements). [?] Many of the aforementioned methods suffer from slow equilibration and reliance on precise references, standards, and/or calibrations. [?] Moreover, these experiments are generally time-consuming and cost-intensive. Thus, it is unfeasible to determine the activity coefficients in all relevant systems experimentally, making predictive methods essential for engineering practice.

Several physical models for activities in electrolyte solutions, such as the excess Gibbs energy (GEG^{\mathrm{E}}) models of Pitzer[?] and Bromley, [?] have been proposed in the literature. These models can reliably generalize across concentration, but their adjustable parameters must be determined by fitting to experimental data for the specific electrolyte, solvent, and temperature of interest. As a consequence, these models cannot generalize over electrolytes, i.e., they cannot be applied to electrolytes for which no activity data are available. This limitation has partially been addressed with the development of LIQUAC and LIFAC, [?, ?, ?], which enable extrapolations to unstudied temperatures and (mixed) solvents, but still require electrolyte-specific cation-anion interaction parameters that have been fit to data for each electrolyte of interest.

Only a few models that enable predictions for solutions of completely unstudied electrolytes have been proposed in the literature. Two examples are the ion-specific Bromley model (IBM), [?], which targets the prediction of electrolyte-specific parameters of the Bromley model based on ion-specific parameters, and the Simoes model, [?], which, similarly, aims at predicting the electrolyte-specific parameters of the Pitzer model based on ion-specific parameters. However, these approaches have limited predictive accuracy and, in the case of the Simoes model, [?], limited applicability, as the ionic radii required as descriptors of the model are not comprehensively available for every ion.

In recent years, machine learning (ML) has emerged as a powerful alternative to and complement of established, physics-based thermodynamic modeling approaches. [?, ?] While purely data-driven ML approaches often lack physical interpretability and robustness, hybrid models that combine established thermodynamic frameworks with data-driven ML models enable generalization across chemical spaces inaccessible to traditional models, effectively closing gaps in established physical models, while retaining thermodynamic consistency. [?, ?, ?, ?, ?]

One interesting class of ML methods in thermodynamics are matrix completion methods (MCMs), [?], and, by extension, tensor completion methods, [?], which have also been combined with physical models and knowledge to yield powerful hybrid approaches for predicting various thermodynamic properties, including activity coefficients, [?, ?, ?, ?, ?, ?] Henry’s-law constants, [?, ?], diffusion coefficients, [?, ?, ?], and densities of aqueous electrolyte solutions. [?] Furthermore, MCMs have been embedded in physical modeling frameworks, enabling prediction of model parameters and thereby significantly enhancing their applicability. [?, ?, ?, ?, ?, ?]

In this work, we present a novel hybrid model for predicting activities in aqueous electrolyte solutions by combining the physics-based Bromley model [?] with an MCM. Within this new hybrid model, which we call Bromley-MCM, the MCM is trained to predict the electrolyte-specific adjustable parameters of the Bromley equation, BCAB_{CA}, by exploiting the fact that these Bromley parameters for a set of electrolytes can be conveniently arranged in the shape of a matrix, where the rows represent the different cations CC, the columns represent the different anions AA, and the entries of the matrix contain the numeric values of BCAB_{CA}. Since experimental data to which BCAB_{CA} can be directly fitted exist only for some electrolytes, i.e., only a small fraction of all possible cation-anion pairs CACA, the prediction of the missing Bromley parameters becomes a matrix completion problem.

To benchmark the developed Bromley-MCM, we use a consolidated database of mean ionic activity coefficients and osmotic coefficients in aqueous electrolyte solutions at 298 ±\pm 1 K, obtained by careful evaluation of data from the Dortmund Data Bank (DDB). [?] We thereby systematically compare its results with the predictive approaches in the literature, namely, the IBM[?] and the model of Simoes,[?] each within its respective scope.

Methodology

Electrolyte Activities

In this work, we address the prediction of activities in aqueous solutions containing a single electrolyte. We thereby assume complete dissociation of the electrolytes in solution following, for an electrolyte CνCAνAC_{\nu_C}A_{\nu_A} that consists of cation CC and anion AA, the reaction

CνCAνA→νCCzC+νAAzA,(1)C_{\nu_C}A_{\nu_A} \to\nu_C C^{z_C} + \nu_A A^{z_A}, \tag*{(1)}

where νi\nu_i is the stoichiometric coefficient and ziz_i is the charge number of ion ii. For brevity, we use CACA to denote the electrolyte in the following, omitting the stoichiometric coefficients. To denote solution composition, we use the overall molality m~\widetilde{m} of the electrolyte, which is the number of moles of electrolyte per kilogram of pure water W as the solvent. For complete dissociation, the molality of an ion mim_i in the solutions is related to the overall molality m~\widetilde{m} via the mass balance

mi=νim~.(2)m_i = \nu_i\widetilde{m}. \tag*{(2)}

We furthermore use the ionic strength II of the solution defined as

I=zC2mC+zA2mA2m0,(3)I = \frac{z_C^2m_C + z_A^2m_A}{2m_0}, \tag*{(3)}

where the division by m0=1 mol kg−1m_0 = 1\ \mathrm{mol}\ \mathrm{kg}^{-1} is introduced to render the ionic strength dimensionless.

As is common for electrolyte solutions, we consider the chemical potentials of the ions in solution normalized according to Henry’s law on the molality scale

μi(T,p,m~)=μiref(T,p,m~→0)+RTln⁡mim0+RTln⁡γi∗(T,p,m~),(4)\mu_i(T,p,\widetilde{m}) = \mu_i^{\mathrm{ref}}(T,p,\widetilde{m} \to0) + RT \ln\frac{m_i}{m_0} + RT \ln\gamma_i^*(T,p,\widetilde{m}), \tag*{(4)}

where μiref(T,p,m~→0)\mu_i^{\mathrm{ref}}(T,p,\widetilde{m} \to0) is the chemical potential of ion ii in the reference state (infinite dilution of the ion), TT is the thermodynamic temperature, pp is the pressure, RR is the universal gas constant, and γi∗\gamma_i^* is the activity coefficient of ii on the molality scale. Combining these equations for both respective ions yields the overall chemical potential of the electrolyte CACA, which in case of complete dissociation can be written as

μ~CA(T,p,m~)=μ~CAref(T,p,m~→0)+RTln⁡νCνCνAνA(m~m0)ν+νRTln⁡γ~±∗(T,p,m~),(5)\widetilde{\mu}_{CA}(T,p,\widetilde{m}) = \widetilde{\mu}_{CA}^{\mathrm{ref}}(T,p,\widetilde{m} \to0) + RT \ln\nu_C^{\nu_C}\nu_A^{\nu_A}\left(\frac{\widetilde{m}}{m_0}\right)^\nu+ \nu RT \ln\widetilde{\gamma}_{\pm}^*(T,p,\widetilde{m}), \tag*{(5)}

where

γ~±∗=((γC∗)νC(γA∗)νA)1ν(6)\widetilde{\gamma}_{\pm}^* = \left((\gamma_C^*)^{\nu_C}(\gamma_A^*)^{\nu_A}\right)^{\frac{1}{\nu}} \tag*{(6)}

is the so-called mean ionic activity coefficient of the electrolyte and

ν=νC+νA.(7)\nu= \nu_C + \nu_A. \tag*{(7)}

For the chemical potential of the solvent water W, we use the normalization according to Raoult

μ~W(T,p,m~)=μ~Wpure liq(T,p)−νMWm~RTϕ(T,p,m~),(8)\widetilde{\mu}_W(T,p,\widetilde{m}) = \widetilde{\mu}^{\mathrm{pure\ liq}}_W(T,p) - \nu M_W\widetilde{m}RT\phi(T,p,\widetilde{m}), \tag*{(8)}

where μ~Wpure liq(T,p)\widetilde{\mu}^{\mathrm{pure\ liq}}_W(T,p) is the chemical potential of pure water W, MWM_W is the molar mass of water, and ϕ\phi is the osmotic coefficient. Again, equation (8) holds for the case of complete dissociation of the electrolyte in the solvent.

In the following, we use γ~±\widetilde{\gamma}_{\pm} and ϕ\phi as measures for the activity of the electrolyte and the solvent water in aqueous electrolyte solutions, respectively.

Database

Raw activity data for γ~±\widetilde{\gamma}_{\pm} and ϕ\phi were taken from the DDB 2026 ”ELE” database (Vapor-Liquid Equilibria of Electrolyte Systems) [?] for binary systems containing exactly one electrolyte and the solvent water. We restricted the scope to these systems because the vast majority of available activity data for aqueous solutions is at 298 K, with very little data at other temperatures. Specifically, we found 92,254 data points for solutions of single electrolytes in water, whereas only 4,180 data points were available for the solvent methanol, and even fewer for other solvents. For the aqueous systems, 43,920 data points are reported at 298 ±\pm 1 K, whereas substantially fewer data points are available at any other temperature. Further details on the data availability are reported in Figure S1 and Figure S2 in the Supporting Information.

Bar plot showing the number of experimental data points for different solvents

Figure S1. Bar plot representing the number of experimental data points for activity data in binary electrolyte solutions (one electrolyte and one solvent) available in the DDB1 for different solvents.

Histogram representing the number of experimental data points for activity data in aqueous solutions of single electrolytes available in the DDB for different temperatures

Figure S2. Histogram representing the number of experimental data points for activity data in aqueous solutions of single electrolytes available in the DDB1 for different temperatures.

Since the effect of pressure on liquid-phase properties is generally small, especially at low to moderate pressures, and data at elevated pressures are extremely scarce, the influence of pressure was neglected in this study. All data in this study were either taken at ambient pressure or at the solvent’s vapor pressure.

The following data consolidation and filtering procedure was applied to the raw data from the DDB; further details are reported in the Supporting Information:

  • Only aqueous systems, i.e., systems with water as the only solvent, were considered.

  • Electrolytes that could not be split into 1 type of cation and 1 type of anion were excluded. One example of an excluded electrolyte is magnesium ammonium phosphate (MgNH4PO4\mathrm{MgNH}_{4}\mathrm{PO}_{4}), which has two types of cations. On the other hand, ionic coordination complexes, which do not further dissociate in solution, such as tris(ethylenediamine)cobalt(III) ([Co(en)3]3+[\mathrm{Co}(\mathrm{en})_{3}]^{3+}), are included and are treated as single ions.

  • Only data reported at 298 ±\pm 1 K were considered.

  • Only data for which the electrolyte concentration is reported in terms of molality m~\tilde{m} were used. We also checked the availability of data reported in other concentration measures, but did not find additional relevant systems.

  • Data points at I>6I > 6 were excluded (which is reported as the upper bound for the applicability of the Bromley model in the literature [?]).

  • The database was divided into one database for γ~±\tilde{\gamma}_{\pm} and one for ϕ\phi, and each was checked for internal consistency. For this purpose, for a given electrolyte (e.g., NaCl), all available data sets (i.e., data reported by individual sources) in the database were compared. If two data points were reported at the same (to the second decimal) molality, the mean of these values was calculated. However, whenever one of these data points deviated by more than 5 % from this mean, the entire data set containing this data point was excluded. This procedure was done for ϕ\phi and γ~±\tilde{\gamma}_{\pm} individually.

  • For each electrolyte, the Bromley parameter BCAB_{\mathrm{CA}} was fitted individually to the considered ϕ\phi and γ~±\tilde{\gamma}_{\pm} data for this electrolyte using a least-squares procedure. If the relative mean residual of the fit exceeded 5 % for either ϕ\phi or γ~±\tilde{\gamma}_{\pm}, the respective electrolyte was excluded from the dataset. This procedure was used since weak electrolytes, for

which the Bromley model is not suited, were not excluded a priori based on their respective solubility products. Instead, only those electrolytes for which the Bromley model reproduced the available experimental data with sufficient accuracy (as specified above) were retained.

  • Finally, for the retained electrolytes for which both ϕ\phi and γ~±\tilde{\gamma}_{\pm} were available, the Bromley model was fit to ϕ−1\phi- 1 and ln⁡γ~±\ln\tilde{\gamma}_{\pm} simultaneously, and electrolytes with residuals greater than 5% were excluded. This procedure was used to numerically verify Gibbs-Duhem consistency of the data for these electrolytes (within the specified tolerance), since the Bromley model itself is Gibbs-Duhem consistent.

We call the database containing all data retained after applying the above-described criteria the full database in the following, which can be represented as a matrix, where rows correspond to the different cations CC and columns to the different anions AA. This matrix is visualized in Figure 1 (left). The numbers of cations, anions, available electrolytes, and data points in our full database are listed in Table 1, column ”Full”. The names of all cations and anions are listed in Table S1 in the Supporting Information. The full database contains data for 83 unique cations and 112 unique anions, with experimental mean ionic activity coefficients γ~±\tilde{\gamma}_{\pm} and/or osmotic coefficients ϕ\phi existing for 478 of those cation-anion pairs (5.1 % of all possible pairs) with a total of 11,533 experimental data points for γ~±\tilde{\gamma}_{\pm} and 13,296 data points for ϕ\phi.

Experimental data availability matrices for the full and reduced databases

Figure 1. Experimental data availability (blue cells) for γ~±\tilde{\gamma}_{\pm} and/or ϕ\phi for cation-anion pairs at T=298±1T = 298 \pm1 K in aqueous systems in the full (left) and reduced (right) databases considered in the present work. For the numbers identifying the cations and anions, see Table S1 and Table S2 in the Supporting Information, respectively. White cells indicate electrolytes for which no experimental data are available in the databases.

FullReducedSimoes
Cations835740
Anions1126227
Electrolytes (%)478 (5.1%)401 (11.3 %)256 (23.7 %)
Data points248562331721663

Table 1. Information on the availability of experimental γ~±\widetilde{\gamma}_{\pm} and/or ϕ\phi data in our full, reduced, and Simoes databases, cf. Figure 1 and Figure 2.

Cation Nr.CationAnion Nr.Anion
1Tetraisobutylammonium1Metaborate
2Triisobutylmethylphosphonium22,2,2-Trichloroacetate
3Tetra-sec-butylammonium34,4’-Bibenzyldisulfonate
4Trimethyloctylammonium4Acetate
5N,N,N-Octylbutyldimethylammonium52-Amino-3-methylbutanoate
6n-Octylammonium62-Amino-4-methylpentanoate
71-Octylpyridinium72-Aminopropanoate
81-Octyl-3-methylimidazolium8Propanoate
91-Heptyl-3-methylimidazolium9Butanoate
10Triethylhexylammonium10Pentanoate
111-Hexyl-3-methylimidazolium11Octanoate
12Triethylpentylammonium12Decanoate
131-Pentyl-3-methylimidazolium13Ethyl malonate

Table S1. Identifiers for cations and anions in the full database (cf. Figure 1).

Cation Nr.CationAnion Nr.Anion
14Butyltriethylammonium14Ethyl sulfate
15Dibutyldiethylammonium15Ethanesulfonate
16Tetrabutylammonium16Ethylbenzene sulfonate
17Tributylmethylphosphonium17Methyl malonate
18Tributylsulfonium18Methyl sulfate
191-Butyl-3-methylimidazolium19p-Anisole sulfonate
20Tetrapropylammonium20Methanesulfonate
211-Propyl-3-methylimidazolium21Thymine
22Tetraethylammonium222,4,6-Trimethylbenzene sulfonate
23Triethylammonium232,5-Dimethylbenzenesulfonate
24Diethylammonium242,4-Dimethylbenzenesulfonate
251-Hexyl-3-methylimidazolium254-Toluenesulfonate
26Tetramethylguanidinium263-Methylsalicylate
27Tetramethylammonium27Cefazolin
282-Hydroxyethyl-trimethylammonium28Tetrachloroaurate
29Trimethyl-(2-trimethylammonioethyl)ammonium29Tetrafluoroborate
30Trimethylammonium30Hexafluorophosphate
31Dimethylammonium31Hexafluoridosilicate
32Timethylsulfonium32Thiocyanate
331-(2-Carboxyethyl)-3-methylimidazolium33Aspartate
341,3-Dimethylimidazolium34Arginine
35Hexaaminecobalt(III)352-Aminoacetate
36Guanidinium36Lysine
37Uranyl37Sulfamate
38Tetraethanol ammonium38Glutamate
39Silver(I)39Sulfanilate
40Aluminium(III)40Adenosine triphosphate
41Barium (II)41Adenine
42Calcium(II)42Dihydrogen citrate
43Cadmiun(II)43Fumarate
44Cerium(III)44Maleate
45Cobalt(II)45Oxalate
46Tris(ethylenediamine)cobalt(III)46Trichloracetate
47Chromium(III)47Trifluoroacetate
48Cesium(I)48Tartrate
49Copper(II)49Hydrogen malonate
50Dysprosium(III)50Malonate
51Erbium(III)51Hydrogen citrate
52Europium(III)52Hydrogen succinate
53Iron(II)53Succinate
54Iron(III)54Hydrogen adipate
55Gadolinium(III)552-Hydroxyacetate
56Proton56Carbonate

Table S1. Table S1 – continued from previous page

Cation Nr.CationAnion Nr.Anion
57Holmium(III)57Mellitate
58Indium(III)584-Hydroxybenzoate
59Potassium(I)59Benzoate
60Lanthanum(III)60Salicylate
61Lithium(I)61Formate
62Lutetium(III)62Nitrite
63Magnesium(II)63Dihydrogen phosphate
64Manganese(II)64Dihydrogen pyrophosphate
65Ammonium65Hydrogen phosphate
66Sodium(I)66Pyrophosphate
67Neodymium(III)67Phosphate
68Nickel(II)68Trifluoromethane sulfonate
69Lead(II)69Ethane-1,2-disulfonate
70Praseodymium(III)70Hydrogen sulfate
71Tris(1,3-Diaminopropane)platinum(IV)71Peroxydisulfate
72Tris(ethylenediamine)plantinum(IV)72Dithionate
73Rubidium(I)73Sulfate
74Scandium(III)744-Hydroxybenzenesulfonate
75Samarium(III)75m-Benzenedisulfonate
76Strontium(II)761,5-Naphthalenedisulfonate
77Terbium(III)77Benzenesulfonate
78Thorium(IV)78Thiosulfate
79Thallium(I)79Sulfite
80Thulium(III)80Benzenesulfinate
81Yttrium(III)81Dihydrogen arsenate
82Ytterbium(III)82Hydrogen arsenate
83Zinc(II)83Arsenate
84Dichromate
85Chromate
86Molybdate
87Nitrate
884-Nitrophenolate
893-Nitrobenzenesulfonate
90Perrhenate
91Selenate
92Pertechnetate
93Tungstate
94Xanthine
95Hypoxanthine
96Uracil
97Dodecahydrododecaborate
98Decahydrodecaborate
99Bromide

Table S1. Table S1 – continued from previous page

Cation Nr.CationAnion Nr.Anion
100Hexacyanocobaltate(III)
101Hexacyanoferrite(II)
102Hexacyanoferrate(III)
103Chloride
104Hexachloroplatinate(IV)
105Fluoride
106Iodide
107Bromate
108Chlorate
109Perchlorate
110Iodate
111Hydroxide
112Tetraphenylborate

Table S1. continued from previous page

To evaluate the predictive accuracy of the hybrid model developed in this work, we use a leave-one-electrolyte-out strategy, in which the model is repeatedly trained on data from all electrolytes except one, whose data are used as test data and compared against the model predictions. This procedure requires data on at least two cation–anion pairs (i.e., different electrolytes) per ion, so we further restricted the full database to include only cations and anions with at least two experimentally available pairs for this analysis. The resulting reduced database is shown in Figure 1 (right) in matrix form. The number of cations, anions, and the number of available electrolytes and data points are listed in Table 1, column ”Reduced”.

The names of the cations and anions included in the reduced dataset are listed in Table S2 in the Supporting Information.

Cation Nr.CationAnion Nr.Anion
11-Hexyl-3-methylimidazolium14,4’-Bibenzyldisulfonate
2Butyltriethylammonium2Acetate
3Tetrabutylammonium3Propanoate
4Tributylsulfonium4Butanoate
51-Butyl-3-methylimidazolium5Ethyl sulfate
6Tetrapropylammonium6Ethanesulfonate
7Tetraethylammonium7Ethylbenzene sulfonate
8Diethylammonium8Methyl sulfate
91-Hexyl-3-methylimidazolium9p-Anisole sulfonate
10Tetramethylguanidinium10Methanesulfonate
11Tetramethylammonium11Thymine
122-Hydroxyethyl-trimethylammonium122,4,6-Trimethylbenzene sulfonate
13Trimethyl-(2-trimethylammonioethyl)ammonium132,5-Dimethylbenzenesulfonate
14Trimethylammonium144-Toluenesulfonate
15Dimethylammonium15Tetrafluoroborate
16Timethylsulfonium16Thiocyanate
17Guanidinium17Sulfamate
18Uranyl18Glutamate
19Silver(I)19Sulfanilate
20Barium (II)20Adenosine triphosphate
21Calcium(II)21Trichloracetate
22Cadmiun(II)22Trifluoroacetate
23Cerium(III)23Hydrogen malonate
24Cobalt(II)24Hydrogen citrate
25Tris(ethylenediamine)cobalt(III)25Hydrogen succinate
26Chromium(III)26Succinate
27Cesium(I)27Hydrogen adipate
28Copper(II)28Carbonate
29Dysprosium(III)29Nitrite
30Erbium(III)30Dihydrogen phosphate
31Europium(III)31Hydrogen phosphate
32Iron(II)32Pyrophosphate
33Gadolinium(III)33Phosphate
34Proton34Ethane-1,2-disulfonate
35Holmium(III)35Peroxydisulfate
36Indium(III)36Sulfate
37Potassium(I)37m-Benzenedisulfonate
38Lanthanum(III)381,5-Naphthalenedisulfonate
39Lithium(I)39Benzenesulfonate
40Lutetium(III)40Dihydrogen arsenate
41Magnesium(II)41Hydrogen arsenate
42Manganese(II)42Arsenate

Table S2. Identifiers for cations and anions in the reduced database (cf. Figure 1).

Cation Nr.CationAnion Nr.Anion
43Ammonium43Dichromate
44Sodium(I)44Chromate
45Neodymium(III)45Nitrate
46Nickel(II)46Perrhenate
47Praseodymium(III)47Selenate
48Rubidium(I)48Pertechnetate
49Samarium(III)49Xanthine
50Strontium(II)50Hypoxanthine
51Terbium(III)51Uracil
52Thorium(IV)52Bromide
53Thallium(I)53Hexacyanocobaltate(III)
54Thulium(III)54Hexacyanoferrate(III)
55Yttrium(III)55Chloride
56Ytterbium(III)56Fluoride
57Zinc(II)57Iodide
58Bromate
59Chlorate
60Perchlorate
61Iodate
62Hydroxide

Table S2. continued from previous page

To enable a fair comparison between our new model and the literature model from Simoes, [?] we had to define an additional restricted database containing only cation-anion pairs within the scope of the Simoes model. For this database, referred to as the Simoes database below, the same above-described consolidation and filtering procedure was applied, except that no data points were excluded because the Bromley model did not fit them well. The reason for not applying this criterion here is that we did not want to introduce a bias in favor of our hybrid model, which is based on the Bromley model architecture, by considering only data that the original Bromley model can well describe. Figure 2 visualizes the Simoes database as a matrix. The number of cations, anions, available electrolytes, and data points in these databases are listed in Table 1, column ”Simoes”, respectively.

Experimental data availability for cation-anion pairs

Figure 2. Experimental data availability for γ~±\widetilde{\gamma}_{\pm} and/or ϕ\phi for cation-anion pairs at T=298±1T = 298 \pm1 K in aqueous systems in the Simoes database. For the numbers identifying the cations and anions, see Table S3 in the Supporting Information. White cells indicate electrolytes for which no experimental data are available.

Cation Nr.CationAnion Nr.Anion
1Tetrabutylammonium1Acetate
2Tetrapropylammonium2Thiocyanate
3Tetraethylammonium3Carbonate
4Tetramethylammonium4Formate
5Uranyl5Nitrite
6Silver(I)6Dihydrogen phosphate
7Barium (II)7Hydrogen phosphate
8Calcium(II)8Phosphate
9Cadmiun(II)9Peroxydisulfate
10Cobalt(II)10Sulfate
11Chromium(III)11Arsenate
12Cesium(I)12Dichromate
13Copper(II)13Chromate
14Dysprosium(III)14Nitrate
15Erbium(III)15Perrhenate
16Europium(III)16Selenate
17Gadolinium(III)17Pertechnetate
18Proton18Bromide
19Holmium(III)19Hexacyanocobaltate(III)
20Potassium(I)20Chloride
21Lanthanum(III)21Fluoride
22Lithium(I)22Iodide
23Lutetium(III)23Bromate
24Magnesium(II)24Chlorate
25Manganese(II)25Perchlorate
26Ammonium26Iodate
27Sodium(I)27Hydroxide
28Neodymium(III)
29Nickel(II)
30Praseodymium(III)
31Rubidium(I)
32Samarium(III)
33Strontium(II)
34Terbium(III)
35Thorium(IV)
36Thallium(I)
37Thulium(III)
38Yttrium(III)
39Ytterbium(III)
40Zinc(II)

Table S3. Identifiers for cations and anions in the Simoes database (cf. Figure 2).

When comparing Figure 1 and Figure 2, as well as the numbers reported in Table 1, it becomes evident that the predictive scope of the Simoes model, [?], i.e., the number of cation-anion pairs that can be predicted with the model, covers only a small fraction of the full and reduced databases considered in this work.

Electrolyte Activity Models

Bromley Model

The Bromley model, which serves as the basis for the new hybrid model developed in this work, is a semi-empirical GEG^{\mathrm{E}} model for electrolyte solutions. It is built on a modified Debye-Hückel limiting law, which is valid at high dilutions of the electrolyte, and adds an empirical extension to describe the deviations from that limiting law observed at higher ionic strengths II. It uses a single electrolyte-specific parameter BCAB_{CA}, which must be fitted to experimental data for each electrolyte of interest, and then allows for generalization of γ~±\tilde{\gamma}_{\pm} and ϕ\phi over II. The Bromley model is given by the following equations (9) to (13) [?].

ln⁡γ~±=−ln⁡(10)Aγ∣zCzA∣I1+I+ln⁡(10)(0.06+0.6BCA)∣zCzA∣I(1+cI)2+ln⁡(10)BCAI(9)\ln\tilde{\gamma}_{\pm} = -\ln(10)\frac{A_{\gamma}|z_C z_A|\sqrt{I}}{1+\sqrt{I}}+\ln(10)\frac{(0.06+0.6B_{CA})|z_C z_A|I}{(1+cI)^2}+\ln(10)B_{CA}I \tag*{(9)}
ϕ=1−ln⁡(10)σAγ∣zCzA∣I3+ln⁡(10)ψ(0.06+0.6BCA)∣zCzA∣I2+ln⁡(10)2BCAI(10)\phi= 1-\ln(10)\sigma\frac{A_{\gamma}|z_C z_A|\sqrt{I}}{3}+\ln(10)\psi\frac{(0.06+0.6B_{CA})|z_C z_A|I}{2}+\frac{\ln(10)}{2}B_{CA}I \tag*{(10)}
c=1.5∣zCzA∣(11)c = \frac{1.5}{|z_C z_A|} \tag*{(11)}
σ=3I1.5[1+I−11+I−2ln⁡(1+I)](12)\sigma= \frac{3}{I^{1.5}}\left[1+\sqrt{I}-\frac{1}{1+\sqrt{I}}-2\ln(1+\sqrt{I})\right] \tag*{(12)}
ψ=2cI[1+2cI(1+cI)2−ln⁡(1+cI)cI](13)\psi= \frac{2}{cI}\left[\frac{1+2cI}{(1+cI)^2}-\frac{\ln(1+cI)}{cI}\right] \tag*{(13)}

In these equations, AγA_{\gamma} is the Debye-Hückel constant, which for water at 298 K is Aγ=0.5098A_{\gamma}=0.5098 (since the original Bromley equations use base 10 logarithms), and zCz_C and zAz_A are the charges of cation CC and anion AA, respectively. We assume complete dissociation in water for all electrolytes considered in this work, i.e., Bromley’s extension for associating ions is not considered.[?]

Ion-Specific Bromley Model

We use the ion-specific Bromley model (IBM),[?] which is based on ion-specific instead of electrolyte-specific parameters, as a predictive benchmark in this work. The idea behind IBM is to express the electrolyte-specific parameter BCAB_{CA} as a combination of two cation-specific parameters BCB_C and δC\delta_C and two anion-specific parameters BAB_A and δA\delta_A according to (14)[?]

BCA=BC+BA+δC⋅δA(14)B_{CA} = B_C + B_A + \delta_C \cdot\delta_A \tag*{(14)}

The ion-specific parameters BiB_i and δi\delta_i for aqueous solutions at 298 K were originally determined and published by Bromley in 1973 using a least-squares fit to the previously available BCAB_{CA}.[?] Since new activity data for aqueous electrolyte systems have been published since then and are now available for a much larger scope of ions, we have determined new ion-specific IBM parameters from our full database using the least-squares method minimize from the scipy.optimize package. Furthermore, we applied the same leave-one-electrolyte-out approach as for our newly developed model to the IBM to compare the predictive performance of both models in a fair way. Further details are given in the computational details section below. Additionally, we compared the fit accuracy (without holding out electrolytes) of the re-parametrized IBM to that of the original IBM,[?] as reported in Figure S4 in the Supporting Information, and found that the re-parametrization using new data from the DDB 2026[?] leads to higher accuracy on our dataset.

Box plots of fit errors for $\phi$ and $\ln \tilde{\gamma}_{\pm}$, comparing IBM refitted and IBM; y-axis AE; legend Mean and Median

Figure S4. Box plots of the ln⁡γ~±\ln\tilde{\gamma}_{\pm} and ϕ\phi fit errors of the original IBM2^2 and the refitted IBM, fitted on the dataset used in this work. Boxes represent interquartile range (IQR), and whiskers denote 1.5 IQR.

Simoes Model

We use the Simoes model,[?] which aims at predicting the parameters of the Pitzer GEG^{\mathrm{E}} model[?] for electrolytes for which no suitable fitting data are available, using descriptors of the ions that make up an electrolyte, as an additional predictive benchmark in this work. The underlying Pitzer model[?] is, just like Bromley’s model,[?] a GEG^{\mathrm{E}} model that generalizes over ionic strength II, but uses more than one electrolyte-specific adjustable parameter. In its most commonly used form, which is also the basis for the Simoes model,[?] three parameters are used (B0B_0, B1B_1, and CϕC_{\phi}). With the Simoes model,[?] B0B_0 and B1B_1 can be predicted as functions of the radii rir_i and the charge numbers ziz_i of the ions, while CϕC_{\phi} is always set to 0. For more details on the Simoes and Pitzer models, we refer to the original publications.[?, ?] In this work, the Simoes model was implemented as described in the original publication, [?] without adjustments, using ionic radii from Marcus, [?] which are the same as those used by Simoes et al. [?] in the development of their model.

Hybrid Bromley-MCM

Figure 3 illustrates how the hybrid model introduced in this work, Bromley-MCM, was developed by embedding a matrix completion method (MCM) into the framework of the Bromley model.

Schematic representation of the hybrid Bromley-MCM

Figure 3. Schematic representation of the hybrid Bromley-MCM for predicting γ~±\widetilde{\gamma}_{\pm} and ϕ\phi in aqueous electrolyte solutions developed in this work. The MCM is embedded in the Bromley model and trained to predict the electrolyte-specific Bromley parameter BCAB_{CA} for unstudied cation-anion pairs, while the Bromley model enables consistent generalization across composition.

While the electrolyte-specific Bromley parameter BCAB_{CA} could directly be fitted only for a small fraction of all electrolytes, given the sparse experimental data for γ~±\widetilde{\gamma}_{\pm} and ϕ\phi, the MCM at the core of Bromley-MCM decomposes the matrix of BCAB_{CA} values, spanned by the considered cations and anions, into the product of two low-rank matrices θ\boldsymbol{\theta} and β\boldsymbol{\beta} containing ion-specific features. Specifically, each Bromley parameter BCAB_{CA} is thereby modeled as

BCA=θC⋅βA(15)B_{CA} = \boldsymbol{\theta}_{C} \cdot\boldsymbol{\beta}_{A} \tag*{(15)}

where θC\boldsymbol{\theta}_{C} and βA\boldsymbol{\beta}_{A} are the vectors containing the features of cation CC and anion AA, respectively. All feature vectors have length KK, a hyperparameter of the method set to K=3K = 3 based on preliminary experiments (cf. Figure S3 in the Supporting Information).

Six heatmaps showing prediction MAE for $\ln \tilde{\gamma}_{\pm}$ and $\phi$ for $K=2$, $K=3$, and $K=4$ across hyperparameters $\sigma_0$ and $\lambda$

Figure S3. Prediction MAE for ln⁡γ~±\ln\tilde{\gamma}_{\pm} and ϕ\phi for different values of the hyperparameters KK, σ0\sigma_0, and λ\lambda calculated by leave-one-electrolyte-out analysis based on the reduced data set, cf. Figure 1 in the manuscript.

Bromley-MCM was trained end-to-end on the γ~±\widetilde{\gamma}_{\pm} and ϕ\phi data from our dataset, thereby directly inferring the ion-specific features stored in θ\boldsymbol{\theta} and β\boldsymbol{\beta}. In theory, both γ~±\widetilde{\gamma}_{\pm} and ϕ\phi contain the same information concerning BCAB_{CA}; we have nevertheless decided to train on both, since for many electrolytes, only one property is available in our database (cf. Figure S8 in the Supporting Information).

Experimental data availability for $\widetilde{\gamma}_{\pm}$ and $\phi$

Figure S8. Experimental data availability for γ~±\widetilde{\gamma}_{\pm} (left) and ϕ\phi (right) for cation-anion pairs at T=298±1T = 298 \pm1 K in aqueous systems in the reduced database used in the present work. For the numbers identifying the cations and anions, see Table S2. White cells indicate missing experimental data for specific electrolytes. Red rows and columns denote cations and anions, respectively, with missing γ~±\widetilde{\gamma}_{\pm} (left) or ϕ\phi (right) data.

Training was performed in a Bayesian framework, which treats all data and parameters as random variables following probability distributions. Similar Bayesian frameworks are described in detail in our previous work; [?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?] we therefore keep the description in the following brief and focused on the specifics relevant to this work.

The goal of Bayesian inference is to find the so-called posterior distribution, i.e., the probability distribution of the model parameters (θ\boldsymbol{\theta} and β\boldsymbol{\beta} here) based on the data (γ~±\widetilde{\gamma}_{\pm} and ϕ\phi here). The posterior was calculated by defining a generative model for the data using two further probability distributions: the prior, which describes the probability of the parameters before training on the data, and the likelihood, which describes the conditional probability of the data given the parameters. In this work, Cauchy distributions centered around μ0=0\mu_0 = 0 with scale σ0=0.2\sigma_0 = 0.2 were chosen as prior for all features θ\boldsymbol{\theta} and β\boldsymbol{\beta}. As the likelihood, each observed value of γ~±\widetilde{\gamma}_{\pm} or ϕ\phi was modeled using a Cauchy distribution with scale parameter λ=0.1\lambda= 0.1, centered at the corresponding model prediction. These predictions were calculated from the Bromley equations (9) - (13), using BCA=θC⋅βAB_{CA} = \theta_C \cdot\beta_A.

Based on the prior and likelihood, the posterior was calculated using Bayes’ law, yielding a probability distribution for each ion-specific feature informed by the training data. Using the mean of these distributions, the electrolyte-specific Bromley parameters BCApredB_{CA}^{\mathrm{pred}} were predicted for all electrolytes that can be built with the studied ions, following equation (15). Finally, the BCApredB_{CA}^{\mathrm{pred}} were used for the prediction of γ~±pred\widetilde{\gamma}_{\pm}^{\mathrm{pred}} and ϕpred\phi^{\mathrm{pred}} using equations (9) - (13), and compared to the respective experimental data, if available. The prediction error of Bromley-MCM is evaluated using leave-one-electrolyte-out analysis, as explained in the computational details section.

We report complete sets of BCApredB_{CA}^{\mathrm{pred}} parameters, obtained by training on our full database in the Supporting Information. Although Bromley-MCM was trained on data for electrolytes that can be (approximately) assumed fully dissociated in solution at the studied conditions, predictions for weak electrolytes are also generated, since some combinations of ions making up two strong electrolytes in our database can form weak electrolytes. As one example, consider sodium acetate (NaAc) and hydrochloric acid (HCl), both strong electrolytes in our database (cf. Figure 1), but acetic acid (HAc) is a weak electrolyte. Predicted BCApredB_{CA}^{\mathrm{pred}} for such electrolytes should thus be used with care, since the Bromley model is not capable of correctly modeling their γ~±\widetilde{\gamma}_{\pm} and ϕ\phi behavior at higher II. Such weak electrolytes include many carboxylic acids, phosphoric acid, arsenic acid, transition-metal oxoacids, and non-quaternary amines. We have marked such electrolytes directly in the tabulated BCAB_{CA} in the Supporting Information.

Computational Details and Evaluation

The hybrid Bromley-MCM was implemented in the probabilistic programming language Stan[?] using its Python package CmdStanPy. Bayesian inference was performed using automatic differentiation variational inference.[?, ?]

The predictive performance of Bromley-MCM and the IBM10^{10} was evaluated using a leave-one-electrolyte-out analysis,[?] whereby the models were trained on a subset of the experimental γ~±\widetilde{\gamma}_{\pm} and ϕ\phi data, including all available experimental data points except those of one ”test” electrolyte CACA to be predicted. By this leave-one-out procedure, predictions for γ~±\widetilde{\gamma}_{\pm} and ϕ\phi were made for truly unseen electrolytes. To evaluate the prediction accuracy of the models, we computed the absolute prediction errors, which, for the predicted quantities y∈{ϕ,ln⁡γ~±}y \in\{\phi, \ln\widetilde{\gamma}_{\pm}\}, are defined as:

AEi=∣yipred−yiexp∣(16)\mathrm{AE}_i = \left|y_i^{\mathrm{pred}} - y_i^{\mathrm{exp}}\right| \tag*{(16)}

for each test data point ii. These pointwise values were aggregated across all experimental data points for a specific electrolyte and are reported as box plots below.

Since our final Bromley-MCM uses K=3K = 3, i.e., three parameters per ion, and the IBM uses only two parameters per ion, we also report prediction errors for a Bromley-MCM version where we set K=2K = 2 to enable a clean comparison of the two model architectures that does not depend on the number of trainable parameters.

For the comparison of Bromley-MCM to the Simoes model, [?] the leave-one-electrolyte results were used for Bromley-MCM, guaranteeing true predictions for unseen electrolytes. By contrast, the Simoes model [?] was used in their latest published versions, including the reported parameters, so that the results for these benchmark models are, for some electrolytes, not true predictions but correlations.

Results and Discussion

Results of Bromley-MCM and Comparison to IBM

Figure 4 shows a box plot of the prediction errors of ln⁡γ~±\ln\tilde{\gamma}_{\pm} and ϕ\phi with Bromley-MCM and IBM, retrained on the same data, on our reduced database (cf. Figure 1). All results are for unseen electrolytes. The results show that the new Bromley-MCM substantially outperforms the retrained IBM for both predicted properties.

For both models, we observe higher prediction errors for ln⁡γ~±\ln\tilde{\gamma}_{\pm} than for ϕ\phi. Given that the original Bromley model – the physical model underlying both approaches – is Gibbs-Duhem-consistent, this is surprising at first glance. This discrepancy may reflect lower quality in the reported γ~±\tilde{\gamma}_{\pm} data. In many cases, γ~±\tilde{\gamma}_{\pm} are derived from ϕ\phi data through Gibbs-Duhem integration. This conversion is particularly sensitive in the low-concentration region, because the infinite-dilution limit provides the integration boundary and small errors in ϕ\phi can propagate into ln⁡γ~±\ln\tilde{\gamma}_{\pm}. Since highly precise measurements in this regime are difficult, some inconsistencies may have been introduced into the reported γ~±\tilde{\gamma}_{\pm} values from the original publications that were not detected by our Gibbs-Duhem verification during data consolidation.

We additionally provide the fit residuals of Bromley-MCM and IBM (Figure S5) and the prediction errors for a Bromley-MCM with K=2K = 2 (i.e., the same number of parameters as the IBM, Figure S6) in the Supporting Information, all of which show the same qualitative results.

Box plot of the $\ln \tilde{\gamma}_{\pm}$ and $\phi$ fit errors for Bromley-MCM and IBM

Figure S5. Box plot of the ln⁡γ~±\ln\tilde{\gamma}_{\pm} and ϕ\phi fit errors on the reduced database of IBM and Bromley-MCM. Boxes represent interquartile range (IQR), and whiskers denote 1.5 IQR.

Box plots of the $\phi$ and $\ln \tilde{\gamma}_{\pm}$ prediction errors for Bromley-MCM and IBM

Figure S6. Box plot of the ln⁡γ~±\ln\tilde{\gamma}_{\pm} and ϕ\phi prediction errors on the reduced database for IBM and Bromley-MCM (with K=2K = 2) evaluated using leave-one-electrolyte-out analysis. Boxes represent interquartile range (IQR), and whiskers denote 1.5 IQR.

Comparison of Bromley-MCM to the Simoes Model

Figure 5 shows the box plot of the prediction errors of ln⁡γ~±\ln\tilde{\gamma}_{\pm} and ϕ\phi for Bromley-MCM and Simoes on the Simoes horizon (cf. Figure 2). The results of Bromley-MCM are true predictions for unseen electrolytes. In contrast, the Simoes model was adopted directly from the literature,2 so its results are partly correlations rather than true predictions. In Figure S7 in the Supporting Information, we report the prediction error of the Simoes model on the seen and unseen electrolytes separately and find similar results to those discussed below.

Box plots of prediction errors for Bromley-MCM and Simoes

Figure 5. Box plot of the ln⁡γ~±\ln\tilde{\gamma}_{\pm} and ϕ\phi prediction errors on the Simoes horizon for Bromley-MCM and the Simoes model. Bromley-MCM was evaluated by leave-one-electrolyte-out analysis, whereas the parameters of the Simoes model were adopted from the original literature.2 Boxes represent IQR and whiskers denote 1.5 IQR.

Box plots of prediction errors for seen and unseen electrolytes

Figure S7. Box plot of the ln⁡γ~±\ln\tilde{\gamma}_{\pm} and ϕ\phi prediction errors on the Simoes horizon for Bromley-MCM and the Simoes model, thereby distinguishing between electrolytes seen by the Simoes model during the training (left) and unseen ones (right). Results of Bromley-MCM are always for unseen electrolytes. Boxes represent IQR, and whiskers denote 1.5 IQR.

Figure 5 shows that Bromley-MCM substantially outperforms the Simoes model2 both on the prediction of the logarithmic mean ionic activity coefficient and the osmotic coefficient.

The Simoes model shows large outliers and a very large interquartile range. Our Bromley-MCM not only predicts aqueous electrolyte activities more accurately than the established Simoes model,[?] but also covers a substantially broader chemical space, enabling predictions for more than 9,000 electrolytes.

Predicted Electrolyte Activities as a Function of Ionic Strength

Figure 6 and Figure 7 show a comparison between the predictions by the three models studied in this work (Bromley-MCM, IBM, and Simoes) for ln⁡γ~±\ln\tilde{\gamma}_{\pm} and ϕ−1\phi- 1 as a function of ionic strength II and the respective experimental data for several electrolytes as examples. Again, the results of Bromley-MCM and IBM are true predictions for unseen electrolytes, whereas the Simoes model has been fitted to data for most of the shown electrolytes. Wherever lines are missing in a plot panel, the Simoes model could not be applied to the electrolyte under consideration.

Prediction of logarithmic mean activity coefficients for exemplary electrolytes in aqueous solutions

Figure 6. Prediction of ln⁡γ~±\ln\tilde{\gamma}_{\pm} for exemplary electrolytes in aqueous solutions at 298 K as a function of ionic strength. Lines: Predictions with different models. Circles: experimental data from DDB.[?]

Prediction of $\phi^{-1}$ in exemplary aqueous electrolyte solutions at 298 K for hydrogen bromide, tris(ethylenediamine)cobalt(III) perchlorate, potassium hydrogen phosphate, sodium acetate, copper nitrate, and ammonium chloride

Figure 7. Prediction of ϕ−1\phi^{-1} in exemplary aqueous electrolyte solutions at 298 K as a function of ionic strength. Lines: Predictions with different models. Circles: experimental data from DDB.[?]

The agreement between the experimental data and the predictions with Bromley-MCM is very good for most electrolytes. All curves show the correct qualitative dependence of ln⁡γ~±\ln\tilde{\gamma}_{\pm} and ϕ−1\phi- 1 on II, with the characteristic minimum at low ionic strength, which is achieved by building the hybrid model on the physics-based Bromley model. For many electrolytes, good agreement is also found for the other models. However, as already shown in Figure 4 and Figure 5, Bromley-MCM outperforms all other approaches overall.

Box plots of prediction errors for Bromley-MCM and IBM

Figure 4. Box plot of the ln⁡γ~±\ln\tilde{\gamma}_{\pm} and ϕ\phi prediction errors of Bromley-MCM and IBM on the reduced database evaluated using leave-one-electrolyte-out analysis. Boxes represent interquartile range (IQR), and whiskers denote 1.5 IQR.

While the Simoes model,2 despite having been fit to data for all shown electrolytes except Potassium hydrogen phosphate (K2HPO4\mathrm{K}_2\mathrm{HPO}_4) and those where no Simoes curve (orange) is present, fails for certain electrolytes, Bromley-MCM also manages to correctly predict the activities of electrolytes that contain organic anions (e.g., Tos−\mathrm{Tos}^{-}, Ac−\mathrm{Ac}^{-}, SCN−\mathrm{SCN}^{-}), electrolytes containing ions with absolute charges greater than one (e.g., Ca2+\mathrm{Ca}^{2+}, Mg2+\mathrm{Mg}^{2+}, Lu3+\mathrm{Lu}^{3+}, PO43−\mathrm{PO}_4^{3-}), or electrolytes that contain ionic complexes (e.g., [Co(en)3]3+[\mathrm{Co}(\mathrm{en})_3]^{3+}).

As can, e.g., be seen in Figure 7 middle left, the prediction of electrolytes containing ions with multiple protonated forms is somewhat worse than that of other electrolytes. While K3PO4\mathrm{K}_3\mathrm{PO}_4 would be expected to behave like a typical strong electrolyte, the resulting PO43−\mathrm{PO}_4^{3-}, like other phosphates, undergoes stepwise protonation and deprotonation. Modeling the activities of such acids with high accuracy is challenging, and alternative models for these systems typically require substantially more adjustable parameters. [?, ?]

Despite some minor shortcomings, mainly due to the limitations of the underlying Bromley model,[?] the results clearly demonstrate that the matrix completion concept is well suited for the prediction of Bromley parameters BCAB_{CA} as the hybrid model resulting from embedding an MCM into the Bromley model substantially outperforms the existing benchmarks in the prediction of γ~±\tilde{\gamma}_{\pm} and ϕ\phi in aqueous electrolyte-containing systems.

Conclusions

In this work, we present a novel hybrid approach for predicting activities in aqueous electrolyte solutions at 298 K by embedding a matrix completion method (MCM) from machine learning (ML) within the Bromley model to predict the Bromley parameter BCAB_{CA}, enabling the consistent modeling of activity coefficients γ~±\tilde{\gamma}_{\pm} and osmotic coefficients ϕ\phi for unstudied electrolyte systems, thereby addressing the limitation of classical electrolyte models as the ones of Bromley [?] and Pitzer [?].

The new hybrid model, Bromley-MCM, was trained end-to-end and evaluated on data for γ~±\tilde{\gamma}_{\pm} and ϕ\phi from a consolidated database, based on raw data from the Dortmund Data Bank, [?] containing experimental data for aqueous solutions of 478 electrolytes, covering 83 unique cations and 112 unique anions. Bromley-MCM significantly outperforms other models reported in the literature that generalize to unstudied electrolytes, namely, the ion-specific Bromley model (IBM) [?] and the Simoes model, [?] in prediction accuracy, while also offering a substantially broader scope, covering more ions, than the Simoes model. While the extrapolation to unstudied electrolytes is enabled by the MCM, the physics-based Bromley model underlying the hybrid Bromley-MCM guarantees smooth and consistent generalization over ionic strength.

With this work, we report a complete set of BCAB_{CA} values for 9,296 electrolytes, which can be used to describe activities in aqueous solution at 298 K. For 8,818 of these electrolytes, no data under these conditions were available in the literature. In future work, the hybrid approach introduced here can be extended to further solvents and the temperature-dependent prediction of activities in electrolyte solutions.

Acknowledgement

We gratefully acknowledge financial support by DFG in the frame of the Research Training Group GRK 2908 ”Valuable Wastewater (WERA)” (grant number 503479768) and the Priority Program SPP 2363 ”Molecular Machine Learning” (grant number 497201843). Furthermore, FJ gratefully acknowledges financial support by DFG in the frame of the Emmy-Noether program (grant number 528649696).

Supporting Information Available

Supporting Information is available:

  • Compound identifiers; hyperparameter optimization; further error analysis; and analysis of data availability. (PDF)

  • Full Bromley parameter set (BCAB_{CA}) for 9296 electrolytes, from training on the full database. (XLSX)

Declaration of generative AI and AI-assisted technologies in the manuscript preparation process

During the preparation of this work the authors used ChatGPT (OpenAI) in order to improve the language of the manuscript and to assist with code development and debugging. After using this tool/service, the authors reviewed and edited the content as needed and take full responsibility for the content of the published article.

References

Prediction of Activities in Aqueous Electrolyte Solutions with Hybrid Machine Learning

Zeno Romero; Maximilian Kohns; Fabian Jirasek

SI_1_.pdf

Ion Identifiers

Tables S1 to S3 list the identifiers for cations CC and anions AA, respectively, covered in Figure 1 to Figure 2.

Database Consolidation

Raw activity data for binary systems containing one electrolyte and one solvent were obtained from the ”ELE” (Vapor-Liquid Equilibria of Electrolyte Systems) database of the Dortmund Databank (DDB) 2026. [1] The DDB features electrolyte solution activity data for various solvents, as shown in Figure S1.

As can be seen in Figure S1, the vast majority of the literature data is available for aqueous systems, i.e., systems with water as the solvent. A substantial amount of data is also available for the solvents methanol, ethanol, and ammonia. In contrast, the number of data points for all other solvents is at least two orders of magnitude smaller. Since water is the most common solvent based on the available data points and the Bromley parameters are solvent-specific, [2] we restricted the dataset for this study to aqueous systems. With this restriction in place, Figure S2 shows a histogram of the number of data points as a function of temperature.

As shown in Figure S2, most data points are available at T=298±1T = 298 \pm1 K. Bromley [2] proposed a correlation for the temperature dependence of the BCAB_{CA} parameters using four temperature-independent adjustable parameters for each BCAB_{CA}, i.e., for each electrolyte. Since fitting these parameters accurately would, firstly, require a substantial amount of data for each electrolyte, and, secondly, substantially increase the complexity of the developed hybrid model, potentially reducing its ability to generalize to unstudied electrolytes, the present study was restricted to data at T=298±1T = 298 \pm1 K, which is also the temperature for which the Bromley model was originally developed.

Furthermore, the dataset was restricted to systems for which either mean ionic activity coefficients γˉ±\bar{\gamma}_{\pm} and/or osmotic coefficients ϕ\phi were available, as well as for which the data were reported using the molality m~\tilde{m} as the concentration measure. Data reported in terms of molarity were excluded, as conversion to molality requires knowledge of the solution density, which is generally unavailable. Likewise, vapor pressure data were not considered because vapor pressure measurements usually lack sufficient accuracy to calculate exact

activity data. In fact, restricting the dataset to molality-based data did not reduce the number of electrolytes it covered.

Since the raw data points were directly adopted from the DDB, it is difficult to provide a reliable estimate of their uncertainty. Many literature sources do not report uncertainties for measured ϕ\phi or γ~±\tilde{\gamma}_{\pm}, and those that do typically state values in the range of 1–5%. Such estimates appear optimistic, as direct comparisons between different sources, where possible, often revealed deviations of up to 10%.

Hyperparameter optimization

Figure S3 shows the prediction error for various combinations of the model hyperparameters KK, σ0\sigma_0, and λ\lambda evaluated by leave-one-electrolyte-out analysis in the form of mean absolute error (MAE) for ln⁡γ~±\ln\tilde{\gamma}_{\pm} and ϕ\phi.

Figure S3 shows that setting K>2K > 2 leads to substantially lower MAE than K=2K = 2; however, there is only marginal change when increasing KK beyond 3. For the K=2K = 2 model that was used to compare our Bromley-MCM to the ion-specific Bromley model[2] (IBM), we chose to set σ0=0.02\sigma_{0} = 0.02 and λ=0.10\lambda= 0.10 since those hyperparameters lead to the lowest prediction MAE at K=2K = 2 for both ln⁡γ~±\ln\tilde{\gamma}_{\pm} and ϕ\phi. Meanwhile, for the K=3K = 3 model, we chose to set σ0=0.20\sigma_{0} = 0.20 and λ=0.10\lambda= 0.10 since those hyperparameters lead to the lowest prediction MAE at K=3K = 3 for ln⁡γ~±\ln\tilde{\gamma}_{\pm}. We consider the marginal improvement for ϕ\phi prediction at K=4K = 4 not sufficient to warrant further increasing the model complexity.

Further Results

Comparison of original and refitted IBM Figure S4 shows the errors for ln⁡γ~±\ln\tilde{\gamma}_{\pm} and ϕ\phi of the original IBM[2] and the refitted IBM, updated with the data used in this work, on the original IBM horizon in the form of a box plot.

Figure S4 shows that updating the IBM with new experimental data substantially improves the fitting accuracy of the model. We thus consider only the refitted version in the following and the main section of this work, and refer to it simply as IBM.

Comparison of IBM and Bromley-MCM (K=3K = 3) Figure S5 shows the residuals of the fit of ln⁡γ~±\ln\tilde{\gamma}_{\pm} and ϕ\phi for IBM and Bromley-MCM on the reduced data set (Figure 1) in the form of a box plot.

Comparison of IBM and Bromley-MCM (K=2K = 2) Figure S6 shows a box plot of the prediction errors of ln⁡γ~±\ln\tilde{\gamma}_{\pm} and ϕ\phi for IBM and Bromley-MCM using K=2K = 2 on the reduced data set evaluated by leave-one-electrolyte-out analysis.

The Figure S5 - Figure S6 show that our new Bromley-MCM outperforms the existing IBM model[2] in all metrics, confirming our conclusions from the main section.

Figure S7 shows a box plot of the prediction errors of ln⁡γ~±\ln\tilde{\gamma}_{\pm} and ϕ\phi for Bromley-MCM and the Simoes model, thereby distinguishing between the electrolytes for which data were used during the training of the Simoes model (left) and electrolytes for which no data were used during the training of the Simoes model (right). The errors reported for Bromley-MCM are, in both cases, for truly unseen electrolytes, since this model was evaluated using leave-one-electrolyte-out analysis.

Bromley-MCM significantly outperforms the Simoes model in both cases, indicating that Bromley-MCM’s capability to extrapolate to unseen electrolytes is superior to that of the Simoes model. Furthermore, even for electrolytes observed during training of the Simoes model, Bromley-MCM yields, on average, lower errors than the fitted Simoes model.

Data Availability of Osmotic and Activity Coefficients

Figure S8 shows the availability of experimental data for cation-anion pairs in the reduced database, thereby distinguishing between available data for γ~±\tilde{\gamma}_{\pm} and for ϕ\phi.

Figure S8 shows that for many cations and anions no γ~±\widetilde{\gamma}_{\pm} data are available. Similarly, for three anions and one cation, no ϕ\phi data are available. By using both γ~±\widetilde{\gamma}_{\pm} and ϕ\phi data during development and training of the new model, its range of applicability could therefore be increased.

References

  1. [1]Dortmund Data Bank. DDBST - Dortmund Data Bank Software And Separation Technology GmbH, Dortmund Data Bank, 2026. https://www.ddbst.com (accessed 2026-07-01).
  2. [2]Bromley, L. A. Thermodynamic properties of strong electrolytes in aqueous solutions. AIChE Journal 1973, 19, 313–320.

Paper details

vlnc:W_zfcfyabu
Published
Added
License
CC BY 4.0
Usage

views · 0

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Computer Science

ChatGPT (OpenAI)

View statement
Looking for related papers…
Contents