Sub 35-ps Single-Photon Stellar Intensity Interferometry of Vega

Abstract

SII enables measurements of stellar photospheres by correlating intensity fluctuations, offering a robust alternative to amplitude-based techniques. With the advent of modern single-photon counting detectors, this method has re-emerged as a powerful technique in stellar interferometry exploiting their ultra-high timing resolution. We determine the stellar diameter of Vega at 405 nm using spatial intensity correlations measured at the C2PU facility, part of the Observatoire de la Cote d'Azur. We employed a setup identical to Leopold et al. (2025). The two campaigns in April and August 2024 used hybrid photodetectors (HPDs; 22.7 ps resolution) and new PhotonPix detectors (34.8 ps resolution). A Photonscore TDC integrated photon arrival times and IRIG-B timestamps for synchronization. Our analysis consisted of calculating auto- and cross-correlation histograms from the recorded data, which were then normalized and corrected for optical path differences. The temporal auto-correlations yield a consistent coherence time of 0.21 ps. This confirms the effectiveness of the PhotonPix detectors despite a slight degradation in timing resolution relative to the HPDs. Combining the data from the two measurement campaigns yields a uniform disk diameter of Vega of 2.97 +/- 0.23 mas. This agrees with the 3.047 mas diameter predicted by the stellar atmosphere model at our observation wavelength, validating our technique and the new PhotonPix detectors for precision SII at sub-35 ps resolution. The integration of advanced single-photon detectors like the PhotonPix into existing IACT SII instruments promises substantial enhancements in signal-to-noise ratio and observational capabilities, particularly with CTA LSTs. Although challenges such as night sky background saturation and precise positioning and guiding remain, SII observations at apparent magnitudes up to 7.8 are within reach.

Introduction

Stellar intensity interferometry (SII) was first demonstrated for visible starlight by Hanbury Brown & Twiss [21]. In this seminal experiment, Hanbury Brown & Twiss (HBT) measured the diameter of the brightest star in the night sky, Sirius (α\alpha CMa). Compared to the amplitude interferometry of Michelson & Pease [34], intensity interferometry avoids the technical challenge of coherently superposing light from two different telescopes. Instead, light intensities are detected locally at the respective telescopes and the corresponding electrical or digital signals are centrally correlated. The simplicity of SII allowed Hanbury Brown et al. [19] to construct the first large-scale stellar interferometer, the Narrabri Stellar Intensity Interferometer (NSII). At the NSII, Hanbury Brown et al. [20] measured the diameters of 32 stars. However, around the same time, Labeyrie [27] detected the first amplitude interferometry fringes of Vega with two separate telescopes. Due to its higher sensitivity per detected photon, amplitude interferometry subsequently replaced SII and is currently the workhorse of stellar interferometry. Instruments like GRAVITY at the VLTI reach magnitudes of >15> 15 (GRAVITY+ Collaboration et al. [14]), enabling interferometry of extra-galactic sources, while the MIRC-X beam combiner at the CHARA array combines light from six telescopes simultaneously for imaging (Anugu et al. [4]).

Recently, SII has received renewed interest due to significant advances in photon detection technology. In this context, Dravins et al. [11] were among the first to recognize the potential of SII when combined with modern arrays of telescopes with large diameters like the Cherenkov Telescope Array (CTA). Here one noteworthy potential contribution is the more dense sampling of stellar visibilities if a large number of telescopes is used, providing camera-like "imaging" at high resolution. The first SII implementation between two telescopes since the NSII was performed by Guerin et al. [17] at the twin 1 m optical telescopes of the C2PU facility, part of the Observatoire de la Côte d’Azur. SII implementations at major Imaging Atmospheric Cherenkov Telescope (IACT) arrays soon followed at MAGIC [3], VERITAS [2], and H.E.S.S. [46]. These SII instruments reach the level of maturity that is necessary to perform stellar diameter surveys [26, 1] and multicolor observations [44]. All SII implementations at IACTs to date operate at blue wavelengths and use conventional photodiodes, which return a photocurrent for light detection.

The newly constructed CTA Large Size Telescopes (LSTs) are special within the IACT category: their active mirror control allows for them to be segmented into sections with anisochronicities ≤100\le100 ps [8]. Their photon timing dispersion thus stays smaller than that of their current electronic signal-acquisition pipeline by a factor of ≥80\ge80 [1]. This means that the SII instruments currently installed at these facilities fall short of their maximum possible signal-to-noise ratio by a factor of ≥5\ge5 [18, 9, 16]. Single-photon detectors can overcome this bottleneck, while also being less sensitive to electronic noise. In practice, however, the large focal spot of large IACTs (≈30\approx30 mm at the focal plane) and the prohibitively large detected photon rate (>100> 100 MHz when observing a mag. 7 star [8]) have so far prevented the adoption of single-photon detectors at IACTs.

We have recently developed and tested two components: (1) a commercial large-area single-photon detector sustaining detection rates up to 100 MHz at visible wavelengths, together with its digitization electronics (PhotonPix and LINTag, respectively, both from Photonscore GmbH), see [24]; and (2) an SII instrument optimized for large-area single-photon detectors [29]. In this paper, we combine these two achievements to measure the diameter of Vega (α\alpha Lyr.) with 82 ps timing resolution, and evaluate the feasibility of using single-photon detectors for SII at IACTs with low photon timing dispersion.

Spatial Intensity Interferometry

The theory of SII can be described in terms of classical thermal fields for starlight, see Hanbury Brown [18] for an in-depth treatment. SII measures the second-order intensity correlation function

g(2)(r,τ)=⟨I(r0,t0)I(r0+r,t0+τ)⟩⟨I(r0,t0)⟩⟨I(r0+r,t0+τ)⟩.(1)g^{(2)}(\mathbf{r},\tau)=\frac{\langle I(\mathbf{r}_0,t_0)I(\mathbf{r}_0+\mathbf{r},t_0+\tau)\rangle}{\langle I(\mathbf{r}_0,t_0)\rangle\langle I(\mathbf{r}_0+\mathbf{r},t_0+\tau)\rangle}. \tag*{(1)}

where II is the instantaneous intensity at a given spacetime point, r\mathbf{r} is the projected baseline between two telescopes positioned at r0\mathbf{r}_0 and r0+r\mathbf{r}_0+\mathbf{r}, respectively, τ\tau is a temporal delay, and ⟨⟩\langle\rangle denotes time-averaging. The second-order correlation function can be interpreted as the conditional probability of detecting a photon at position r0+r\mathbf{r}_0+\mathbf{r} and time t0+τt_0+\tau after having previously detected a photon at position r0\mathbf{r}_0 and time t0t_0 [13]. We use this to measure g(2)(r,τ)g^{(2)}(\mathbf{r},\tau) by digitizing and correlating single-photon arrival time streams at two distant telescopes.

Since the two telescopes are placed at fixed positions separated by a fixed baseline b\mathbf{b}, the star’s motion across the sky changes the projected baseline r=∣r∣\mathbf{r}=|\mathbf{r}| [28]. We show the typical geometry and coordinate systems for SII, adapted to the telescope site, in Figure 1. Photons emitted by the star at the same time can be delayed at one telescope (Omicron in Figure 1) with respect to the other by a distance called the optical path delay OPD =∣OPD∣=|\mathbf{OPD}|. During measurement acquisition, we need to compensate for the change in OPD by shifting the correlation histograms accordingly. Calculating the OPD and projected baseline is straightforward if we know the angle β\beta between b\mathbf{b} and the unit vector w\mathbf{w} that points towards the star, since the OPD, b\mathbf{b}, and r\mathbf{r} form a right triangle. The projected baseline r\mathbf{r} always lies inside the plane with normal vector w\mathbf{w}, called the uvuv-plane. Inside this plane, we choose basis vectors v\mathbf{v} (that points towards celestial north) and u\mathbf{u} to make up a complete right-handed coordinate system. In this paper, we thus follow the definition of the uu, vv, ww coordinate system by Thompson et al. [41].

Figure 1. Coordinate systems used in stellar interferometry following the conventions in Thompson et al. [41], drawn for the C2PU telescopes (see § 3.1). The optical path delay (OPD) is shown in orange for a given absolute baseline b\mathbf{b} shown in blue, and the projected baseline r\mathbf{r} shown in green. The projected baseline r\mathbf{r} lies inside the uvuv-plane, where v\mathbf{v} points towards celestial north and the normal vector w\mathbf{w} points towards the star.

To connect g(2)(r,τ)g^{(2)}(\mathbf{r},\tau) with source properties, we rewrite it in terms of the spatial and temporal first-order correlation functions, denoted g(1)(r)g^{(1)}(\mathbf{r}) and g(1)(τ)g^{(1)}(\tau) respectively, [33]:

g(2)(r,τ)=1+∣g(1)(r)∣2∣g(1)(τ)∣2.(2)g^{(2)}(\mathbf{r},\tau)=1+\left|g^{(1)}(\mathbf{r})\right|^2\left|g^{(1)}(\tau)\right|^2. \tag*{(2)}

Eq. (2) relies on the Siegert relation [40], which is valid for thermal light. Both g(1)(r)g^{(1)}(\mathbf{r}) and g(1)(τ)g^{(1)}(\tau) are related to source properties via Fourier transform relationships, called the van Cittert-Zernike theorem and the Wiener-Khinch­tine theorem [33]. The van Cittert-Zernike theorem states that g(1)(r)g^{(1)}(\mathbf{r}) can be derived from the Fourier transform of the source intensity distribution, and the Wiener-Khinch­tine theorem expresses that g(1)(τ)g^{(1)}(\tau) can be calculated by the Fourier transform of the normalized source spectrum. Using the simplest possible model for a star, a circular disk of uniform intensity with angular diameter δ\delta, we obtain

g(1)(r)=2J1(πrδ/λ)πrδ/λ,(3)g^{(1)}(\mathbf{r})=2\frac{J_1(\pi r\delta/\lambda)}{\pi r\delta/\lambda}, \tag*{(3)}

where J1J_1 is the Bessel function of first kind and first order, and λ\lambda is the central observation wavelength. We use this result to construct the uniform disk (UD) model fit function that we employ for fitting ∣g(1)(r)∣2|g^{(1)}(r)|^2. More specifically, suppose we have acquired multiple measurements of g(2)(rn,τ)g^{(2)}(r_n,\tau) at fixed star positions on the night sky, which correspond to certain projected baselines rnr_n. We define the coherence time τc\tau_c as the area under the peak of the second-order temporal auto-correlation function

τc=∫[g(2)(r=0,τ)−1] dτ=∫∣g(1)(τ)∣2 dτ.(4)\tau_c = \int\left[g^{(2)}(r=0,\tau)-1\right]\,\mathrm{d}\tau= \int|g^{(1)}(\tau)|^2\,\mathrm{d}\tau. \tag*{(4)}

Thus, temporal integration and rearranging of Eq. (2) yields

τc∣g(1)(rn)∣2=∫[g(2)(rn,τ)−1] dτ.(5)\tau_c |g^{(1)}(r_n)|^2 = \int\left[g^{(2)}(r_n,\tau)-1\right]\,\mathrm{d}\tau. \tag*{(5)}

As a notational shorthand, we call τc∣g(1)(rn)∣2:=τcV2(rn)\tau_c |g^{(1)}(r_n)|^2 := \tau_c V^2(r_n) the visibility curve, where VV is the interferometric visibility. To evaluate stellar diameters using the UD model, we thus use a fitting function ff

f(r,τc,δ)=τc∣2J1(πrδ/λ)πrδ/λ∣2,(6)f(r,\tau_c,\delta)=\tau_c\left|\frac{2J_1(\pi r\delta/\lambda)}{\pi r\delta/\lambda}\right|^2, \tag*{(6)}

with free parameters τc\tau_c and δ\delta to the area under the curve of the second-order temporal correlation functions recorded at different baselines rnr_n.

Without considering excess noise, the signal-to-noise ratio (S/N) of SII, derived by Hanbury Brown [18] for the case of correlating classical photocurrents, has been extended to the single-photon-counting regime by Dalal et al. [9] and Guerin et al. [16]:

S/N=Aϵoptϵdetnσ11+a∣g(1)(r)∣2bνtmeas2=Aϵoptϵdetnσ11+a∣g(1)(r)∣2tmeasκΔtRMS.(7)\begin{aligned} \mathrm{S/N} &= A\epsilon_{\mathrm{opt}}\epsilon_{\mathrm{det}}n\sigma\frac{1}{1+a}|g^{(1)}(r)|^2\sqrt{\frac{b_\nu t_{\mathrm{meas}}}{2}} \\ &= A\epsilon_{\mathrm{opt}}\epsilon_{\mathrm{det}}n\sigma\frac{1}{1+a}|g^{(1)}(r)|^2\sqrt{\frac{t_{\mathrm{meas}}}{\kappa\Delta t_{\mathrm{RMS}}}}. \tag*{(7)} \end{aligned}

Here AA is the telescope mirror area, ϵopt\epsilon_{\mathrm{opt}} is the product of all optical efficiencies of the detection setup, ϵdet\epsilon_{\mathrm{det}} is the quantum efficiency of the detectors, nn is the incident photon flux, σ\sigma is a normalized spectral density factor, aa is the fraction of stray light compared to the signal intensity, bνb_\nu is the frequency bandwidth of the photocurrent detection chain, ΔtRMS\Delta t_{\mathrm{RMS}} is the RMS width of the corresponding temporal resolution of the detection setup, and tmeast_{\mathrm{meas}} is the measurement time. Going from the 3dB frequency bandwidth to the RMS timing resolution of a detection setup using single-photon counters requires multiplication with a correction factor κ=4π≈7.09\kappa=4\sqrt{\pi}\approx7.09. All temporal resolutions in this paper are given in RMS units. Note that the S/N as defined in Eq. (7) does not depend on the spectral or polarization filtering of the incident light Hanbury Brown [18].

Even though the S/N of SII is independent of optical filtering, practical SII implementations employ it to reduce the photon load on the detectors while at the same time increasing the coherence time. Yet, this filtering, which is performed at each telescope individually, can introduce systematic errors in the measured coherence time if it is not identical. To quantify this systematic coherence loss we introduce coherence factors η\eta that allow us to rewrite Eq. (2) to

g(2)(r,τ)=1+ηspecηpol∣g(1)(r)∣2∣g(1)(τ)∣2.(8)g^{(2)}(r,\tau)=1+\eta_{\mathrm{spec}}\eta_{\mathrm{pol}}|g^{(1)}(r)|^2|g^{(1)}(\tau)|^2. \tag*{(8)}

For the polarization coherence factor ηpol\eta_{\mathrm{pol}} we write the two polarizations as two Jones vectors where one is rotated with respect to the other by an angle θ\theta:

ηpol=cos⁡2(θ).(9)\eta_{\mathrm{pol}}=\cos^2(\theta). \tag*{(9)}

To calculate the spectral overlap coherence factor ηspec\eta_{\mathrm{spec}} we use the ratio of σ\sigma as defined in Hanbury Brown [18] under the assumption that the spectral response of the detector does not vary over the narrow spectral detection range:

ηspec=σoffsetσideal(10)\eta_{\mathrm{spec}}=\frac{\sigma_{\mathrm{offset}}}{\sigma_{\mathrm{ideal}}} \tag*{(10)}

Here σoffset\sigma_{\mathrm{offset}} is calculated using the two slightly different filter transmission spectra and σideal\sigma_{\mathrm{ideal}} is the average of the transmissions assuming that the filter at telescope 1 overlaps perfectly with the filter at telescope 2. For identical filtering at both telescopes, both coherence factors are equal to 1.

Methods

Telescopes

Our measurements were carried out at the C2PU facility (UAI code R87), part of the Observatoire de la Côte d’Azur at the Calern plateau in southern France. C2PU is located at 43°45′13.2″ North and 06°55′22.7″ East at an altitude of 1274 m. Placed roughly on the east-west line, C2PU offers twin telescopes with a Cassegrain secondary focus at a separation of approximately 15 m. The telescope in the west dome is called Omicron, and the one in the east dome, Epsilon. The telescopes use an equatorial yoke mount and have a primary mirror diameter of 1.04 m, a focal length of 13 m, and a focal ratio of f/12.5f/12.5.

The pointing coverage of both telescopes is similar, but Epsilon’s tighter constraints define the observation times for both telescopes. The mounting flange of Epsilon is rotated by 10° with respect to the mounting flange of Omicron. In addition, Epsilon’s pupil is nearly 24% smaller than that of Omicron, due to a primary mirror baffle. Moreover, the focus of the Epsilon telescope is approximately 70 mm shorter compared to that of the Omicron telescope. The latter constraint can be compensated for by moving the secondary mirror, which shifts the focus appropriately. The absolute positions of the Epsilon and Omicron telescopes within the epoch 2024.72 reference frame were measured in September 2024 in collaboration with the Institut Géographique National. This measurement used the total-station technique and measured the coordinates of both telescopes against a common set of reference pillars. It fixes the 3D baseline vector of the C2PU telescopes to an accuracy of Δb≤0.24\Delta b\leq0.24 mm for each vector component. This introduces a potential systematic timing error of ≤3Δb/c=1.4\leq\sqrt{3}\Delta b/c=1.4 ps in the OPD correction, which is negligible when compared to the timing resolution of our detectors.

Experimental setup

We used the same optical and mechanical setup described in detail in Leopold et al. [29]. This setup first collimates the starlight, and then filters it using an ultra-narrow bandpass from Alluxa with a 2 nm full width at half maximum (FWHM) centered at 405 nm and a polarizing beam splitter. At each telescope, the light is sent to two single-photon detectors via a 50:50 beam splitter to enable measurements of the auto-correlation function at both telescopes. Lenses of appropriate focal length are placed in front of each single-photon detector to converge the collimated and filtered starlight to its active area. To operate two telescopes, we doubled the setup, accounting for the 10∘10^\circ difference in mounting on Epsilon to observe the same polarization state at both telescopes. We estimate the maximal angle between the polarizers at the two telescopes to be θ≤1∘\theta\le1^\circ due to tolerances in the flange plate, which leads to a negligible polarization coherence loss of ηpol≥0.9997\eta_{\mathrm{pol}} \ge0.9997. Using high resolution filter spectra obtained from the filter manufacturer, we calculate a spectral coherence factor of ηspec=0.996\eta_{\mathrm{spec}} = 0.996, which we use in our data evaluation, as detailed below. The loss in coherence is caused by a 0.080.08 nm shift in the filter’s central wavelength. In laboratory tests we measured a maximum filter tilt of ≤0.5∘\le0.5^\circ in its mount and a beam collimation of ≤0.05∘\le0.05^\circ divergence in our setup. Using the theory presented in Macleod & Macleod [32] we calculate a central wavelength blue shift of ≤0.004\le0.004 nm and a filter transmission broadening of ≤0.003\le0.003 nm. These effects can thus be neglected in the calculation of our spectral coherence factor.

We observed Vega using two types of single-photon detectors: In April 2024, we used hybrid photodetectors (HPDs) manufactured by Becker & Hickl GmbH [6] with an active area of 66 mm diameter together with custom constant-fraction discriminators (CFDs) for signal discrimination. In Leopold et al. [29] we measured the quantum efficiency of the HPDs to be 22.7%22.7\% at 405405 nm. We used lenses with a focal length of 4040 mm directly attached to the C-mount threads in the HPDs to converge the light beam.

directly attached to the C-mount threads in the HPDs to converge the light beam. In addition, we observed Vega in August 2024 using the newly developed PhotonPix detectors Karl et al. [24] to validate their use for SII. These detectors allow for a significantly higher maximum photon count rate (100100 MHz) and a higher quantum efficiency of ≈35%\approx35\% at 405405 nm than the HPDs, and could thus be used for SII at ACTs. The PhotonPix detectors already provide a discriminated output, so no external CFD is needed. Due to the larger active area of 88 mm diameter, lenses with a focal length of 4545 mm were used to converge the beam. Both detector types have time resolutions of ≤22\le22 ps at detection rates of around 44 MHz for the individual detectors.

The other parts of the measurement setup were unchanged between our observations of Vega in April and August 2024. We show the scheme of our complete SII instrumentation as installed at C2PU in Figure 2. All four detectors were connected to the time-to-digital converter (TDC), the LINTaq manufactured by Photonscore GmbH [37]. Cables with a mutual delay of at least 1212 m (49.249.2 ns) were used to shift the measured correlations out of the crosstalk region of the TDC. Due to attenuation in the cables, different thresholds were set at each TDC channel. The detectors at the Omicron telescope were connected to the TDC on channels 1 and 2, and the detectors at the Epsilon telescope to the TDC channels 3 and 4. The TDC then sends the data to the evaluation PC via a central 10G switch.

Topology of the measurement setup during the two measurement campaigns

Figure 2. Topology of the measurement setup during the two measurement campaigns in April and August 2024. Our optical setups were mounted to the telescopes in the Omicron and Epsilon domes. The remaining equipment was located in the focal room behind the Omicron dome, but in this sketch it has been expanded to the full extent of the C2PU building for better readability (for details see text).

Due to the high timing resolution of the detectors, the OPD correction needs to be accurate to the ps level. We accomplished this by using submillimeter-accurate telescope coordinates and external synchronization of the TDC to UTC time. To this end, we used two White Rabbit (WR; [30]) nodes, one configured as master and one configured as slave. The WR nodes were manufactured by Safran Electronics & Defense [39]. Each second, the WR slave sends an IRIG-B time code that references the WR internal time to the TDC, where the time code’s rising and falling edges are digitized. The WR slave is locked to the WR master via a bidirectional optical fiber link. The WR master clock is disciplined by the clock in an NTP time server (Bürk Mobatime DTS 4160) via its 10 MHz and pulse-per-second (PPS) coaxial output. The clock in the time server is locked to UTC via a GPS receiver placed on the roof of the observatory building. Unfortunately, the WR master node could not be used as a boundary clock, so we set the internal time of the WR master from NTP time supplied to the PC by the time server via the USB interface, giving us an absolute synchronization accuracy of 1 s to UTC. Since the OPD of Vega varied by a maximum of 2.8 ps/s, this error was acceptable, but could be improved by using a WR switch as the master, which directly supports NTP/PTP input. More importantly, the time-code distribution via WR allows extensions of our measurement setup up to a baseline of several km while keeping ps-level synchronization by using a second WR slave node connected to a second TDC. For this application, the TDC oscillator has to be disciplined by the 10 MHz clock output of the WR slave node, which is supported by the LINTag.

Data evaluation

The data that were recorded to disk on the PC contained photon arrival times for all four detectors and timestamps for the rising and falling edges of the IRIG-B. Data acquisition was chunked into 1-minute intervals to provide manageable time stream file sizes of < 2 GiB when observing Vega. We used a custom correlator software written in C# to decode the IRIG-B timestamps and separate the photon arrival time streams into 1 s chunks marked by the respective IRIG-B timestamp. For each 1 s chunk, we calculated six different g(2)(τ)g^{(2)}(\tau) histograms and saved them to disk: the two auto-correlations of detectors mounted at the same telescope (channel pairs: 1 ↔ 2, 3 ↔ 4) and the four cross-correlations of detectors mounted at different telescopes (channel pairs: 1 ↔ 3, 1 ↔ 4, 2 ↔ 3, 2 ↔ 4). These histograms were calculated with a width of 250 ns and a bin size of 1 ps to allow for easy histogram shifting during OPD correction. This also requires the histograms to be flat for time differences τ larger than the dead time of the single-photon detector. This was accomplished by computing them using the multi-start multi-stop technique. This semi-live correlation pipeline can handle total incident photon rates of > 400 MHz and can delete the time-stream file after correlation to save disk space.

When analyzing the correlation histograms, we first normalized both the auto- and cross-correlations with post-recorded normalization histograms measured in our laboratory using white light. For the OPD correction of the cross-correlations, we used the Python package Skyfield developed by Rhodes [38] to obtain high-precision on-sky positions of the observed star for each 1 s chunk. For each of these chunks, we computed the angle β\beta and calculated the OPD, the projected baseline, and its uu and vv components, and shifted the four cross-correlations according to the calculated OPD. After processing all histograms of the current observation this way, we added those recorded for each of the six channel pairs and rebinned them to 10 ps. We call the results of this pipeline the full auto- and cross-correlations.

Instead of adding up all cross-correlations, we could also choose to add them up in sections based on the hour angle of their observation. Since the uvuv-plane tracks only shift marginally for consecutive nights, this sectioning by hour angle effectively corresponds to sectioning into more accurate slices of uu and vv and thus projected baselines. An arbitrary mini-observation time per hour angle can be set, leading to m=⌊total observation timeminimum observation time⌋m = \left\lfloor\frac{\text{total observation time}}{\text{minimum observation time}} \right\rfloor sections over which we equally distributed the total observation time. We call the resulting 4×m4 \times m histograms the hour angle-sectioned cross-correlations, which were also rebinned to 10 ps.

After rebinning, we used a Gaussian fit to center the full data and compensate for cable delay. We then averaged the channel pairs that correspond to auto- and cross-correlations to get 2+m2 + m processed histograms. Each of these histograms corresponds to data taken at a baseline rnr_n. For each processed histogram, we numerically integrated g(2)(rn,τ)−1g^{(2)}(r_n,\tau) - 1 to get a single value for τcV2\tau_c V^2. The integration used symmetric bounds covering 97.5% of the area under the curve of a timing-resolution measurement recorded with the respective detectors and a femtosecond pulsed laser. Due to atmospheric turbulence and imperfect guiding, the RMS width of both the auto- and cross-correlations was larger than the RMS of the timing resolution measurement. If we had used the integration bounds obtained from the femtosecond pulsed laser measurements, we would have systematically underestimated our values for τcV2\tau_c V^2 in the numerical integration. Instead we rescaled the integration boundaries by the ratio of the Gaussian fit widths of the timing resolution measurement and the respective correlation measurement.

For the hour angle-sectioned cross-correlation, we used the integration bounds obtained from the full cross-correlation. We then rescaled the cross-correlation by 1/ηspec≈1.0041/\eta_{\mathrm{spec}} \approx1.004 to account for the imperfections in spectral overlap of the two interference filters. Error bars for τcV2\tau_c V^2 follow from Gaussian error propagation of the histogram bin errors, which we take as the standard deviation of a long section of the histogram far from the peak. To validate this approach we calculated the fraction by which our calculated noise exceeds the expected shot noise, which is 0.4% for the April and 0.2% for the August 2024 campaign. Our data is thus very close to being shot noise limited. Error bars for the projected baselines rnr_n were obtained as the standard deviations of the projected baselines of all 1 s chunks contained within one hour angle slice. The resulting curve was fitted using Eq. (6) and orthogonal distance regression (ODR) implemented in SciPy ([43]) to obtain UD diameters. The ODR fitting accounts for the error bars both in the projected baseline and in the measured coherence.

Stellar atmosphere model

We computed synthetic squared visibilities for a model of Vega at 405 nm, employing stellar radiation field output from the PHOENIX code ([22]) and the methods of Aufdenberg et al. [5]. Using the parameters from Monnier et al. [35], Vega is a nearly pole-on rapid rotator, the rotation axis being inclined 6.2° from the line of sight (position angle 302°), rotating at 217 km s−1^{-1} at its equator, 77% of its angular break-up rate. As a result of this rotation, Vega exhibits both limb and gravity darkening, the latter characterized by the von-Zeipel exponent β=0.23\beta= 0.23 which results in a temperature gradient of 1214 K between the 10700 K pole and 9845 K equator. A polar gravity of log⁡10g=4.1\log_{10} g = 4.1 (cgs units) and mass of 2.14 M⊙M_{\odot} correspond to a polar radius of 2.42 R⊙R_{\odot}. The true angular diameter is 3.30 mas with a parallax of 130.23 mas [42]. With the parameters above, we computed a grid of 20 PHOENIX stellar radiation fields and interpolated these intensities to build map of Vega’s photosphere on sky, see Figure 3. We then fit a uniform disk model to the synthetic squared visibilities evaluated at nine points in the u,vu,v-plane. The prediction at 405 nm is that the strongly limb and gravity darkened Vega with an angular diameter of 3.300 mas appears to be 3.047 mas as a uniform disk.

Figure 3. Synthetic intensity map for Vega at 405 nm (upper) and corresponding squared visibilities with uniform disk fit (lower).

Measurement Campaigns

The first campaign took place from April 3 to April 10, 2024, using HPDs, CFDs, and the LINTAG from Photonscore. We observed Vega for 10.2 h during the nights of April 4, 5, and 6, 2024. Due to adverse weather conditions, we were unable to open the dome to observe Vega during the other nights. During the observation nights, we achieved an average count rate of 2.84 MHz for Vega, which was in line with our expectations considering the attenuation by the atmosphere. We set the minimum observation time for hour angle-based sectioning of the projected baselines to 3 h, resulting in mApril=3m_{\mathrm{April}} = 3 hour angle sections for the cross-correlation.

The second campaign took place from August 12 to August 23, 2024. The HPDs and CFDs were replaced by the PhotonPix detectors to validate their use for SII. We observed Vega for 30.3 h. Observations were interrupted by high clouds, strong winds, and high humidity. The count rates at Epsilon were approximately 42% lower than those observed at the Omicron telescope. This was resolved by removing the baffle of the Epsilon telescope at the end of the night of August 14, 2024. Since we also observed under non-optimal conditions, we attained only an average count rate of 2.62 MHz, despite the nearly 54% higher quantum efficiency of the PhotonPix detectors. We set the minimum observation time for hour angle-based sectioning of the projected baselines to 5 h, resulting in mAugust=6m_{\mathrm{August}} = 6 hour angle sections for the cross-correlation.

Results and Discussion

Temporal auto-correlations

Figure 4 shows the combined data for temporal auto-correlations measured in April and August 2024. From the narrow-band interference filter spectra, we calculated an expected coherence time of τc=0.21\tau_{\mathrm{c}} = 0.21 ps at zero-baseline with V2=1V^2 = 1. Both the measurement recorded in April 2024 and the measurement recorded in August 2024 reproduce this value well and lie within each other’s uncertainty, see Table 1.

AUCS/NRMS[g(2)(τ)−1g^{(2)}(\tau)-1]
Apr. 20240.201 ± 0.020 ps10.021.4 ± 2.2 ps
Aug. 20240.214 ± 0.016 ps13.429.1 ± 2.0 ps

Table 1. Parameters extracted from the measurement data of temporal auto-correlations shown in Fig. 4. AUC refers to the numerically integrated area under the curve of g(2)(τ)g^{(2)}(\tau). The S/N shown here is the S/N of the area under the curve of g(2)(τ)g^{(2)}(\tau).

Due to the slightly worse timing resolution of a PhotonPix compared to that of an HPD, the RMS of the correlation peak increases by a factor of 1.36; see Table 1. This is disadvantageous for our visibility-recovery scheme: integrating over more temporal bins increases the noise of the area-under-the-curve integral. When comparing the S/N of the observations in April and August 2024 we insert into Eq. (7) to calculate the expected improvement in S/N:

2.62 MHz2.84 MHz30.3 h10.2 h21.4 ps29.1 ps=1.36(11)\frac{2.62\ \mathrm{MHz}}{2.84\ \mathrm{MHz}}\sqrt{\frac{30.3\ \mathrm{h}}{10.2\ \mathrm{h}}\frac{21.4\ \mathrm{ps}}{29.1\ \mathrm{ps}}} = 1.36 \tag*{(11)}

This result agrees well with the observed 1.34 times larger S/N we measured in August when compared to the April measurement. Yet, both the timing resolution of the PhotonPix and that of the HPD lie well below the temporal resolution of current and future IACTs such as MAGIC or the CTA LSTs [25].

Cross-correlations

Figure 5 shows the cross-correlations combining all detector pairs. From the auto-correlation results, we expect the cross-correlation measured in August 2024 to have higher S/N, but to also show worse RMS timing resolution. The values displayed in Table 2 support these expectations. For our April 2024 measurements, however, the RMS timing resolution between the autoand cross-correlations barely changes when comparing the results in Tab. 1 and Tab. 2. For reasonably accurate tracking (approximately 10 arcsec between both telescopes) of Vega, this is the result we expect. In contrast, in August 2024 the auto- and cross-correlation RMSs differ by more than their 1σ1\sigma error bars, though they remain compatible within 1.2σ1.2\sigma. Still, this nearly 20% deviation deserves further investigation in future observations, as it cannot be explained by telescope tracking defects.

AUCS/NRMS[g(2)(τ)−1g^{(2)}(\tau)-1]
Apr. 20240.117 ± 0.013 ps9.222.7 ± 2.4 ps
Aug. 20240.123 ± 0.011 ps11.234.8 ± 2.8 ps

Table 2. Parameters extracted from the measurement data of cross-correlations shown in Fig. 5. AUC refers to the numerically integrated area under the curve of g(2)(τ)g^{(2)}(\tau). The S/N shown here is the S/N of the area under the curve of g(2)(τ)g^{(2)}(\tau).

Temporal auto-correlation results for the April and August 2024 campaigns

Figure 4. Temporal auto-correlation result for the April 2024 campaign (upper) and for the August 2024 campaign (lower) with corresponding error bars. The Gaussian fit used for centering and RMS estimation is shown in orange. AUC refers to the numerically integrated area under the curve of g(2)(τ)g^{(2)}(\tau). The measurement result fits well to the expected coherence time of 0.21 ps.

Altogether, despite consisting of four cross-correlations rather than two auto-correlations, the cross-correlations have lower S/N than the auto-correlations. Assuming that all detectors detect equal photon rates and that the histograms are shot-noise-limited, the expected decrease in S/N can be calculated as 2/2×1/V2(r)2/\sqrt{2}\times1/V^2(r). Using the UD diameters fitted to the individual measurements in Sect. 5.3, we expect the S/N of the cross-correlation measurement to be decreased by a factor of 0.82 ± 0.09 (April 2024) and 0.86 ± 0.11 (August 2024) with respect to the auto-correlation measurement, which is in agreement with our results (see Tab. 1 and Tab. 2).

Cross-correlations combining all detector pairs for the April and August 2024 campaigns

Figure 5. Cross-correlations combining all detector pairs for the April (upper) and August (lower) 2024 campaign with corresponding error bars. The Gaussian fit used for centering and RMS estimation is shown in orange. AUC refers to the numerically integrated area under the curve of g(2)(τ)g^{(2)}(\tau).

Compared to previous photon-counting SII measurements with RMS timing resolutions of ≥ 212 ps ([15, 45, 23] (Modzsen et al. 2025)), our results improve the timing resolution by a factor of > 5. Furthermore, our measurements are the first spatial SII measurements using single-photon-counting detectors at the blue wavelength typically used by SII instruments at IACTs.

Comparison to a stellar atmosphere model for Vega

Fitting directly to the total auto- and cross-correlations is possible, but the fit error would then be limited by the large projectedbaseline error. We thus separated our observations into equal observation time hour angle sections, namely m=3m = 3 hour angle sections for the April measurement and m=6m = 6 hour angle sections for the August measurement (see Sec. 4), which gives a smaller projected baseline error—and thus a more accurate fit. Figure 6 shows the uvuv-plane coverage of the recorded histograms, the hour angle sections, and the average uu and vv coordinates within these sections. Note that due to the difference in observation month, Vega follows a different track in the uvuv-plane for our two measurement campaigns.

Figure 6. Average uvuv coordinates and total uvuv-plane coverage of the April (upper) and August (lower) 2024 campaign. Different slices of the hour angle are marked in different colors, and the average uvuv coordinates of each slice are shown with their respective error bars and average projected baselines. Since the measurement is sliced so that each slice has equal observation time, the slices contain different hour angles and do not end at the hour angle boundaries shown as dashed gray lines. For faster rendering, and since each 1 s chunk produces a single uvuv point, we plot only every 25th uvuv point to form the continuous line.

In Figure 7, we fit the UD model to the hour angle sectioned visibility curves measured in April and August 2024, respectively. Using the same uvuv-plane points, we fit a UD model to the results of our stellar atmosphere model (see also § 3.4) to generate our baseline expectation. For Vega at 405 nm, this results in an angular diameter of 3.047 mas. Vega is a rapid rotator observed nearly pole-on, so we expect identical visibilities in all quadrants of the uvuv-plane; fitting a single UD diameter should therefore converge well. Both the measurement taken with the HPDs in April 2024 and the measurement taken with PhotonPix detectors in August 2024 reproduce our expectation within their error bars, at 3.12 ±\pm 0.40 mas and 2.90 ±\pm 0.28 mas fitted UD diameters, respectively. Combining the April and August 2024 data, we obtain a UD diameter of 2.97 ±\pm 0.23 mas (Figure 7), which agrees with our stellar-atmosphere-model expectation at an S/N of 12.9. This result was obtained in 40.5 h of total observation time.

Figure 7. Visibility curve for the April (left), August (middle) 2024 campaign, and the combined data (right). The April campaign used HPDs and CFDs from Photonscore, whereas the August 2024 campaign used the PhotonPix detector. The cross-correlation data were rebinned according to the hour angle as shown in Figure 6. In the right panel, data points in black correspond to the campaign in April 2024 and blue data points correspond to the campaign in August 2024. The UD fit for the combined data (right) yields an angular diameter of 2.97 ± 0.23 mas for Vega, which is in agreement with the stellar atmosphere model.

High time resolution SII with single-photon detectors at IACT arrays?

Recently, Cortina et al. [8] have introduced a possible upgrade to existing SII instruments at IACTs with active mirror control (AMC) and parabolic mirrors like the CTA LSTs. Their Butterfly’s eye approach segments the large, high-focal-ratio IACT mirrors into smaller sub-mirrors, each made of a few existing facets and illuminating its own single-photon detector. This is beneficial because it reduces both the timing anisochronity and the focal ratio when compared to the full telescope dish. For segmentation into more than 7 sub-mirrors, anisochronities of 60 ps FWHM (≈25.5\approx25.5 ps RMS) can be reached, and 5 nm FWHM instead of the more conventional >20> 20 nm FWHM optical filters can be used. Cortina et al. [8] note that this parameter change makes the use of single-photon detectors with large area and high time resolution, like the Becker&Hickl HPDs or the PhotonPix, feasible and more importantly beneficial to all SII science cases.

In the following we use our stellar diameter results of Vega together with telescope parameters of the CTA LSTs taken from Cortina et al. [8] and Abe et al. [1] to independently gauge the possible relative uncertainty on the UD of a star at different apparent magnitudes using a 7-detector Butterfly’s eye configuration equipped with PhotonPix detectors. Table 3 summarizes the parameters we use for our calculation. Further we assume that the night sky background can be reduced to approximately 9.5 mag. at the LSTs under dark sky conditions as discussed in Cortina [7] and that the star has similar spatial visibilities at the 100 m baselines of the CTA LSTs as Vega has at the 15 m baseline of C2PU. The latter criterion corresponds to a star with angular diameter 0.45 mas. For our estimation we start with the UD S/N and measurement time obtained during the April 2024 observation, but still assume that the LSTs are equipped with PhotonPix detectors. We assume PhotonPix detectors for two reasons. First, their larger active area better fits the constraints at the IACTs. Second, their higher quantum efficiency should outweigh their slightly worse timing resolution and let them outperform the HPDs—which they would have in August 2024 had the observing conditions been better. To avoid count-rate loss from detector dead time, we limit ourselves to detected rates below 30 MHz Karl et al. [24], which for a 7The practical implementation of such a Butterfly’s eye camera, however, would place rigid requirements on the accuracy of the 3D-positioning and guiding of the LSTs. Allowing a 10% sensitivity drop from guiding and positioning jitter, split equally between the two telescopes, requires knowing each telescope’s 3D position to 0.55 cm RMS and tracking the star with an RMS guiding accuracy of 0.19 arcmin. The necessary positioning accuracy can be achieved using modern total stations, which enable sub-mm accurate position measurements that can be performed live if needed Løsler et al. (2013), but the required pointing accuracy is below the LSTs 1 arcmin tracking accuracy Dalchenko & Heller [10]. The necessary pointing accuracy could be achieved after post-processing Foffano et al. [12], which would necessitate storing and reprocessing at least intermediate histograms.

AA [m2^2]ϵopt\epsilon_{\mathrm{opt}}Δtopt\Delta t_{\mathrm{opt}} [ps]Δtdet\Delta t_{\mathrm{det}} [ps]ncorr\sqrt{n_{\mathrm{corr}}}
C2PU0.850.305-34.81
LSTs3700.625.534.86\sqrt{6}

Table 3. List of telescope parameters for the C2PU telescopes and the four CTA north site LSTs in a 7-detector Butterfly’s eye configuration equipped with PhotonPix detectors. Parameters for the LSTs were taken from Cortina et al. [8] and Abe et al. [1]. AA is the primary mirror area, ϵopt\epsilon_{\mathrm{opt}} is the product of all optical efficiencies, Δtopt\Delta t_{\mathrm{opt}} and Δtdet\Delta t_{\mathrm{det}} are the RMS widths of the individual telescope anisochronities and two-detector timing resolution, and the ncorr\sqrt{n_{\mathrm{corr}}} factor accounts for the multiple independent baselines measurable between the four LSTs but not between the two C2PU telescopes.

detector Butterfly’s eye configuration with 5 nm filter bandwidth corresponds to apparent magnitudes above 5.7. Following the treatment in Cortina et al. [8] we calculate the expected S/N of the target’s UD diameter after an observation time of 20 h according to Eq. (7). The results are plotted in Figure 8. Our estimations show that under the conditions of this simulation we expect to be able to measure the angular diameter of a mag. 7.8 star to an S/N of 10.0 in 20 h. For a mag. 7.8 star, the detected rate per detector with the Butterfly’s eye camera at the LSTs would be about 3 MHz, compatible with our measured rates of Vega, though at 2.5 times the optical bandwidth. Our expected S/N is lower than the expected S/N of approx. 22 reported by Cortina et al. [8]. Since our results are based on past observation runs and taking into account that the PhotonPix has better RMS timing resolution but lower quantum efficiency than the detectors considered in their study, this result is expected.

Figure 8. Expected S/N of the UD diameter measurement of a star with a given B-band magnitude observed for 20 h with 4 LSTs equipped with a 7-detector Butterfly’s eye cameras based on the PhotonPix detector.

Conclusion

We have demonstrated stellar intensity interferometry measurements of Vega at 405 nm with sub-35 ps RMS timing resolution, achieving the highest temporal precision reported for spatial SII to date. Using two different single-photon-counting detector types, hybrid photodetectors with 22.7 ps timing resolution and the newly developed PhotonPix detectors with 34.8 ps timing resolution, we measured angular diameters of 3.12 ± 0.40 mas and 2.90 ± 0.28 mas in April and August 2024, respectively. Combining both campaigns yields a diameter of 2.97 ± 0.23 mas with an S/N ratio of 12.9, obtained in 40.5 h total observation time. These measurements agree with stellar atmosphere model predictions taking into account both limb and gravity darkening, validating both our methodology and the PhotonPix detector technology for precision astronomical applications.

Our results represent a factor >5> 5 improvement in timing resolution compared to previous photon-counting SII campaigns and constitute the first spatial SII measurements using single-photon-counting detectors at blue wavelengths (405 nm) employed by IACT-based SII instruments. We have validated the use of White Rabbit technology for UTC synchronization, enabling accurate optical path difference corrections and supporting future extension to longer baselines and multi-site configurations. We have also successfully tested a new large-area detector, the PhotonPix, and validated its use in an SII instrument. Looking toward implementation at IACTs, we confirmed that a Butterfly’s eye camera equipped with only seven PhotonPix or HPD detectors is feasible from the photon detection point of view. Such an instrument, if deployed at the 4 CTA LSTs, would allow the measurement of the UD diameter of stars up to mag. 7.8 with an SNR of ≥10\ge10 in observation times of around 20 h as extrapolated from our results. We however note that highly accurate telescope positioning and star tracking are necessary prerequisites for the successful implementation of a Butterfly’s eye camera instrument, as is adequate control of the night sky background even during dark time.

Data Availability

The data directly supporting the plots are available at https://doi.org/10.22000/u7wqh6nus0pd9wpz. The raw photon event stream can be supplied upon reasonable request from the corresponding authors.

Acknowledgements. We cordially thank the team of the Observatoire de la Côte d’Azur for letting us perform measurements at their telescopes. We acknowledge the Institut Géographique National (IGN) for the precise geodetic measurements of the telescope positions. This work made use of the High Performance Cluster "Vega" at Embry-Riddle Aeronautical University.

References

  1. [1]Abe, S., Abhir, J., Acciari, V. A., et al. 2024, Monthly Notices of the Royal Astronomical Society, 529, 4387
  2. [2]Abeysekara, A. U., Benbow, W., Brill, A., et al. 2020, Nature Astronomy, 4, 1164
  3. [3]Acciari, V. A., Bernardos, M. I., Colombo, E., et al. 2019, Monthly Notices of the Royal Astronomical Society, 491, 1540
  4. [4]Anugu, N., Le Bouquin, J.-B., Monnier, J. D., et al. 2020, The Astronomical Journal, 160, 158
  5. [5]Aufdenberg, J. P., Mérand, A., Coudé du Foresto, V., et al. 2006, ApJ, 645, 664
  6. [6]Becker & Hickl GmbH. 2017, HPM-100-06/07: Ultra-High Speed Hybrid Detectors for TCSPC, v2
  7. [7]Cortina, J. 2005, Astrophysics and Space Science, 297, 245
  8. [8]Cortina, J., Cifuentes Santos, A., Hassan, T., & Frías García-Lago, F. 2025, Publications of the Astronomical Society of the Pacific, 137, 125004
  9. [9]Dalal, N., Galanis, M., Gammie, C., Gralla, S. E., & Murray, N. 2024, Phys. Rev. D, 109, 123029
  10. [10]Dalchenko, M. & Heller, M. 2023, Imaging Atmospheric Cherenkov Telescopes pointing determination using the trajectories of the stars in the field of viewarxiv.org/abs/2310.04101
  11. [11]Dravins, D., LeBohéc, S., Jensen, H., & Núñez, P. D. 2013, Astroparticle Physics, 43, 331, seeing the High-Energy Universe with the Cherenkov Telescope Array - The Science Explored with the CTA
  12. [12]Foffano, L., Carosi, A., della Volpe, D., et al. 2021, in Proceedings of 37th International Cosmic Ray Conference — PoS(ICRC2021), ICRC2021 (Sissa Medialab), 712
  13. [13]Fox, M. 2006, Quantum optics: an introduction, Oxford Master Series in Physics, 6 (Oxford University Press, USA)
  14. [14]GRAVITY+ Collaboration, Abuter, R., Allouche, F., et al. 2022, A&A, 665, A75
  15. [15]Guerin, W., Dussaux, A., Fouché, M., et al. 2017, Monthly Notices of the Royal Astronomical Society, 472, 4126
  16. [16]Guerin, W., Hugbart, M., Tolila, S., et al. 2025, Comptes Rendus. Physique, 26, 659
  17. [17]Guerin, W., Rivet, J.-P., Fouché, M., et al. 2018, Monthly Notices of the Royal Astronomical Society, 480, 245
  18. [18]Hanbury Brown, R. 1974, The intensity interferometer; its application to astronomy (Taylor & Francis, Halsted Press)
  19. [19]Hanbury Brown, R., Davis, J., & Allen, L. R. 1967, Monthly Notices of the Royal Astronomical Society, 137, 375
  20. [20]Hanbury Brown, R., Davis, J., & Allen, L. R. 1974, Monthly Notices of the Royal Astronomical Society, 167, 121
  21. [21]Hanbury Brown, R. & Twiss, R. Q. 1956, Nature, 178, 1046
  22. [22]Hauschildt, P. H., Barman, T., Baron, E., Aufdenberg, J. P., & Schweitzer, A. 2025, A&A, 698, A47
  23. [23]Horch, E. P., Weiss, S. A., Klaucke, P. M., Pellegrino, R. A., & Rupert, J. D. 2022, The Astronomical Journal, 163, 92
  24. [24]Karl, S., Leopold, V., Richter, S., et al. 2025, in SPIE Defense and Commercial Sensing 2025, ed. Z. Sodnik, N. Karafolas, & B. Cugny, Vol. 666, International Society for Optics and Photonics (SPIE), 666
  25. [25]Karl, S., Zmija, A., Richter, S., et al. 2022, Monthly Notices of the Royal Astronomical Society, 512, 1722
  26. [26]Kieda, D., Davis, J., LeBohec, T., Lisa, M., & Matthews, N. K. 2021, The VERITAS-Stellar Intensity Interferometry (VSII) survey of Stellar Diametersarxiv.org/abs/2108.09774
  27. [27]Labeyrie, A. 1975, The Astrophysical Journal Letters, 196, L71
  28. [28]Labeyrie, A., Lipson, S. G., & Nisenson, P. 2006, An Introduction to Optical Stellar Interferometry (Cambridge: Cambridge University Press)DOI
  29. [29]Leopold, V. G., Karl, S., Rivet, J.-P., & von Zanthier, J. 2025, Journal of Astronomical Telescopes, Instruments, and Systems, 11, 035005
  30. [30]Lipiński, M., Włostowski, T., Serrano, J., & Alvarez, P. 2011, in 2011 IEEE International Symposium on Precision Clock Synchronization for Measurement, Control and Communication, 25–30DOI
  31. [32]Macleod, H. A. & Macleod, H. A. 2010, Thin-film optical filters (CRC press)
  32. [33]Mandel, L. & Wolf, E. 1995, Optical Coherence and Quantum Optics (Cambridge University Press)
  33. [34]Michelson, A. A. & Pease, F. G. 1921, Proc Natl Acad Sci U S A, 7, 143
  34. [35]Monnier, J. D., Che, X., Zhao, M., et al. 2012, ApJ, 761, L3
  35. [37]Photonsource GmbH. 2024, LINTag: High-Throughput Single-Photon-Streaming
  36. [38]Rhodes, B. 2019, Generate high precision research-grade positions for stars, planets, moons, and Earth satellites, https://ui.adsabs.harvard.edu/abs/2019ascl.soft07024R, astrophysics Source Code Library, ascl:1907.024
  37. [39]Safran Electronics & Defense. 2023, White Rabbit LEN: The cost effective node to distribute synchronization, Datasheet, Safran Electronics & Defense, accessed: 2026-01-08
  38. [40]Siegert, A. 1943, On the fluctuations in signals returned by many independently moving scatterers (Radiation Laboratory, Massachusetts Institute of Technology)
  39. [41]Thompson, A. R., Moran, J. M., & Swenson, G. W. 2017, Interferometry and synthesis in radio astronomy (Springer Nature)
  40. [42]van Leeuwen, F. 2007, A&A, 474, 653
  41. [43]Virtanen, P., Gommers, R., Oliphant, T. E., et al. 2020, Nature Methods, 17, 261
  42. [44]Vogel, N., Zmija, A., Wohlleben, F., et al. 2024, Monthly Notices of the Royal Astronomical Society, 537, 2334
  43. [45]Zampieri, L., Naletto, G., Burtovoi, A., Fiori, M., & Barbieri, C. 2021, Monthly Notices of the Royal Astronomical Society, 506, 1585
  44. [46]Zmija, A., Vogel, N., Wohlleben, F., et al. 2023, Monthly Notices of the Royal Astronomical Society, 527, 12243

Paper details

vlnc:W_zqawuxem
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 0

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents