betaFeedback

WorksPhysics and Astronomy

Calibration-Free Broadband Reconstructive Spectrometer based on Conical Phase Modulation

Abstract

Reconstructive spectrometers (RSs) shift spectral analysis from hardware-heavy dispersion to encoding-decoding schemes. In the speckle-based RSs, spectra are encoded into disordered intensity patterns and then recovered algorithmically. However, characterizing such spectral-encoding transmission matrices (TMs) typically demands empirically complex calibrations, which rely on expensive tunable light sources to generate known wavelengths. In this work, we demonstrate a fully calibration-free RS that leverages conical phase modulation from an axicon. The target spectra are encoded into a Bessel-form intensity profile, enabling computational construction of a deterministic TM and thus completely removing the need for optical calibration. With this computer-generated TM, broadband spectral reconstruction is experimentally achieved across a 650 nm range (1050-1700 nm)–nearly three times the bandwidth of existing calibration-simplified RSs–while a spectral resolution of 2.9 nm remains comparable to that of these counterparts. Compared with an RS requiring optical calibration for equivalent performance, our solution achieves an approximate 36-fold cost reduction.Unlike most speckle RSs, the axicon RS requires no fixed input polarizer, further enhancing energy efficiency and simplicity through polarization-insensitive operation. To the best of our knowledge, this is the first reported experimentally calibration-free RS, featuring superior simplicity, practicality, and cost-effectiveness for practical applications.

Introduction

Spectrometers play an indispensable role in modern industry and scientific research, with widespread applications in material characterization, hyperspectral imaging, and other fields [1, 2, 3, 4, 5]. However, conventional methods are typically limited by large size, heavy weight, and high cost, which restrict their application in specific scenarios (see Figure 1a). In recent years, advances in computational power and algorithms have enabled the development of reconstructive spectrometers (RSs) based on complex spectral-spatial mappings [6, 7, 8, 9, 10]. This approach significantly reduces the burden of dispersive optics and allows for spectral analysis within a small footprint and lightweight structure. Generally, devices with distinctive wavelength-dependent responses can act as spectral encoders. Algorithms are capable of recovering or approximating the original spectrum from the observed signals, even if the encoded intensities are not strictly spatially separated and may even be mixed or scrambled. Disordered waveguides [11, 12], fibers [13, 14], metasurfaces [15, 16], and chaotic optical cavities [10, 17, 18] have been employed in such systems. Light propagating through these opaque media may undergo strong scattering [19, 20], complex interference [21, 22], energy coupling [23, 24], or random diffraction [15, 16], leading to an irregular speckle pattern at the detector—a spectral encoding process that is hard to characterize analytically. To make the back-end spectral decoding problem tractable, it is essential to empirically acquire the prior knowledge of the front-end encoding model (see Figure 1b). This is typically achieved by calibrating the spectral-spatial transmission matrix (TM) using tunable light sources.

Schematic of our proposed RS

Figure 1. Schematic of our proposed RS. a, In a conventional spectrometer, incident light is dispersed and propagates a long path before wavelengths are strictly concentrated onto corresponding spatial pixels, allowing the spectrum to be read out directly. b, A conventional RS typically involves three steps: experimental calibration, front-end encoding, and back-end decoding. Before the unknown spectrum is entirely encoded into intensity signals by a compact device, a tunable light source generates massive known wavelengths to calibrate the encoder. An algorithm then reconstructs the spectrum from the calibration and measurement data. c, Our RS employs an axicon for an analytically deterministic encoding, bypassing experimental calibration entirely. The encoding TM is readily derived from nominal device parameters via simple computation. d, Comparison of conventional spectrometers, conventional RS, and our RS in terms of compactness, coding efficiency, and cost-performance. e, Approximate relationship between optical calibration complexity and number of spectral channels. f, A brief survey of RS development, focusing on the relationship between the number of calibrated channels and reconstructed channels. The gray plane corresponds to the most cases with MCalibrated=MReconstructedM_{\mathrm{Calibrated}} = M_{\mathrm{Reconstructed}}, and the light purple plane to the existing cases with MCalibrated=1M_{\mathrm{Calibrated}} = 1. Dark purple dot represents this work with MCalibrated=0M_{\mathrm{Calibrated}} = 0.

Specifically, TM calibration is required to span all target wavelength channels over the full operational range of the RS. Such a procedure is labor-intensive and resource-demanding, with the cost becoming even higher in special wavebands where tunable light sources are scarce [25, 26]. The calibration process also undermines the system’s simplicity and practicality. Therefore, reducing or even removing the requirement for calibration has become a critical pursuit for RSs, and has attracted significant research attention in recent years. Previous work has attempted to achieve wavelength reconstruction at a finer resolution than the calibration resolution of existing devices [18, 27, 28]. And another research trend is to explore how to minimize the number of calibration wavelengths. To enable spectral reconstruction with sparser calibration, a numerical model first optimized from single-wavelength experimental calibration is utilized to predict speckle outputs of disordered metasurfaces across a 220-nm range [29]. In contrast to disordered mappings, ordered one-to-many spectral-spatial mappings offer an alternative route. The parabolic mapping exhibited by a planar 1D photonic crystal cavity enables determining the entire TM using bichromatic calibration, with a limited working range to tens of nanometers [29, 30]. Advancing this direction, a pinhole-based RS scheme is proposed [31], which exploits the deterministic correspondence between the Fraunhofer diffraction pattern and the incident wavelength. A simple monochromatic calibration combined with an affine transformation allows constructing a TM over a 200 nm range. However, the amplitude restriction introduced by the micron-sized pinhole drastically degrades energy efficiency. Capturing the diffraction pattern even requires detection with ultra-high dynamic range. According to Fraunhofer diffraction theory [32], the far-field propagation of the light field follows a Fourier transform model, with signal intensity decaying rapidly from the center to the edges. The resulting dynamic range can reach a level of 10710^{7} [33]—beyond the capability of standard cameras.

Although the above efforts have enabled simplified calibration for RSs, achieving truly calibration-free operation remains a critical open challenge (see Figure 1f). In this work, we demonstrate the first fully calibration-free RS system, which completely eliminates the need for experimental pre-calibration of the spectral encoder (see Figure 1c). By employing the conical phase modulation of an axicon, a deterministic and analytically tractable spectral-spatial mapping is established, thereby converting the incident spectrum into a Bessel-shaped intensity distribution. The spectral response function of the system can be directly derived from its nominal parameters, and its validity is thoroughly verified in our experiments. We realize broadband spectral reconstruction over a 650 nm bandwidth (1050–1700 nm), with a coefficient of determination (R2R^{2}) of 0.9999 relative to a commercial spectrometer. This operating bandwidth is nearly three times that of existing calibration-simplified RSs. Spectral lines separated by 2.9 nm can be resolved, a performance comparable to those systems. Compared with an RS requiring optical calibration for equivalent performance, our solution achieves an estimated cost reduction of about 36-fold (evaluated using the equipment in our laboratory). The proposed spectral reconstruction scheme uses commercially available components and features a compact monolithic architecture, thus avoiding sophisticated high-precision fabrication. In addition, the full-band encoding and phase-modulation mechanism, together with its polarization-insensitive response, ensures high optical throughput efficiency. The advantages and positioning of this work within the spectrometer community are summarized in Figure 1d-Figure 1f.

Principles

The axicon is a widely used optical phase modulation device for applications including Bessel beam generation [34], optical coherence tomography [35], and so on. Considering the case of a parallel beam incident normally on an axicon, where the base angle of the axicon is α\alpha, the maximum clear aperture radius is RR, and the refractive index is nn.

A cylindrical coordinate system is established with the optical axis as the zz-axis, and the polar coordinate plane passing through the apex of the axicon is defined as the (r,θ)(r, \theta) plane. Under the paraxial approximation, the complex amplitude transmittance function of the axicon can be expressed as follows [36, 37, 38]:

f(λ,r)={exp⁡[−2πλj(n−1)αr],r≤R0,r>R(1)f(\lambda,r)=\begin{cases} \exp\left[-\frac{2\pi}{\lambda}j(n-1)\alpha r\right], & r\le R \\ 0, & r>R \end{cases} \tag*{(1)}

where jj is the imaginary unit, λ\lambda is the optical wavelength, and rr is the radial distance from the apex on the rear surface of the axicon. Furthermore, a transverse plane perpendicular to the optical axis behind the axicon is defined as the (ρ,ϕ)(\rho,\phi) plane. By applying the Fresnel diffraction formula in cylindrical coordinates and under the simplification of a unit-amplitude, normally incident plane wave, the resulting intensity distribution at a longitudinal position zz behind the axicon is derived as (detailed derivation is provided in Supplementary S1): where J0J_0 represents the zero-order Bessel function of the first kind. Based on Eq. (2), we are able to simulate the wavelength-dependent spatial intensity pattern behind the axicon (see Method for details). As schematically illustrated in Figure 2a, the diameter of the central spot and the distribution of concentric rings vary correspondingly with wavelength. Since the intensity distribution is independent of the azimuthal angle ϕ\phi (as given by Eq. (2)) and thus rotationally symmetric, we select only the horizontal radial cross-sectional profile for further analysis (Figure 2b, Figure 2c), which can greatly reduce data redundancy and allow for a higher acquisition frame rate [39]. A full-band spectral-spatial TM can be further generated by arranging the 1-D intensity profiles column-wise (Figure 2d).

Axicon for spectral encoding and synthetic spectrum reconstruction

Figure 2. Axicon for spectral encoding and synthetic spectrum reconstruction. a, The intensity distribution pattern after axicon modulation exhibits wavelength dependence. b, Simulated global intensity distribution corresponding to a single wavelength, with a size of N×NN \times N. c, Simulated one-dimensional horizontal profile with a size of N×1N \times1. d, Full-spectrum TM generated by computer. Synthetic spectral reconstruction spanning 1050–1700 nm using e, the pseudoinverse, and f, the regularization-based algorithm.

The computer-generated TM is critical for spectral encoding and decoding process. For an unknown spectral input, the intensity distribution recorded by the sensor can be modeled as a weighted superposition of monochromatic patterns: I(ρ)=∫T(ρ,λ)S(λ)dλI(\rho)=\int T(\rho,\lambda)S(\lambda)\mathrm{d}\lambda, where I(ρ)I(\rho) represents the intensity at position ρ\rho of the imaging sensor, S(λ)S(\lambda) denotes the power at wavelength λ\lambda, and T(ρ,λ)T(\rho,\lambda) is the device’s spectral response at ρ\rho for wavelength λ\lambda. In discretized form, this relationship simplifies to a linear system:

I=TS(2)\mathbf{I}=\mathbf{T}\mathbf{S} \tag*{(2)}

where I∈RN×1\mathbf{I}\in\mathbb{R}^{N\times1} is a vector representing measured intensity at each pixel of the sensor and S∈RM×1\mathbf{S}\in\mathbb{R}^{M\times1} is a vector representing the discretized spectrum. NN and MM denote the observed spatial channel number and the spectral channel number under test. T∈RN×M\mathbf{T}\in\mathbb{R}^{N\times M} is the computer-generated TM.

In a conventional spectrometer, the T\mathbf{T} is an identity matrix, and each wavelength contributes intensity only at its specific spatial location; namely, the mapping is one-to-one. In contrast, in this work, T\mathbf{T} distributively contains a large number of nonzero entries, such that each wavelength component contributes intensity at all spatial positions; hence, there is a one-to-many mapping. Moreover, the raw measurements here carry no direct physical meaning, and the probe spectrum must be reconstructed algorithmically. Following the approach in the studies [10, 11], we first synthesize the observed intensities using simulated spectra and a TM perturbed by added Gaussian noise, thereby validating the effectiveness of the spectral reconstruction algorithm in our axicon encoding system. According to Eq. (3), the unknown spectrum S\mathbf{S} can be recovered by multiplying the observed I\mathbf{I} by the inverse of the known T\mathbf{T}: S=T+I\mathbf{S}=\mathbf{T}^{+}\mathbf{I}. Here, ++ denotes the Moore-Penrose pseudoinverse, as T\mathbf{T} is not necessarily square. In practice, the ill-posedness of the equation system renders the matrix inversion susceptible to noise, leading to inaccurate results (see Figure 2e for reconstructing widely tunable spectra). To improve the reconstruction accuracy, we introduce an additional regularizer and solve the following optimization problem:

min⁡S≥0{∥I−TS∥22+Γ(S)}(3)\min_{\mathbf{S}\geq0}\left\{\left\lVert\mathbf{I}-\mathbf{T}\mathbf{S}\right\rVert_2^2+\Gamma(\mathbf{S})\right\} \tag*{(3)}

Here, the non-negativity constraint ensures physical plausibility of the recovered spectral values. Γ(S)\Gamma(\mathrm{S}) represents the regularization term. As an illustration, by applying ℓ1\ell_1-norm regularization to enforce sparsity in a broadband range, the spectral reconstruction performance is improved from Figure 2e to Figure 2f under the same measurement conditions. Based on the priors of spectra in terms of smoothness and gradient, ℓ2\ell_2-norm regularization and total variation regularization can also be employed [1]. For detailed implementation of our regularization algorithms, please refer to the Methods section and Supplementary Information S2.

Results

In this section, we verify the capability of using purely computer-generated TM for spectral reconstruction in experiments, with the setup presented in Figure 3a (see Method for details). Figure 3b displays the 2D observed intensity pattern corresponding to 1050 nm and 1700 nm. Figure 3c,Figure 3d show a comparison between the simulated and experimentally observed horizontal intensity profiles at these two representative wavelengths, with Pearson correlation coefficients (see Method for definition) as high as 0.9961 and 0.9975, respectively.

Axicon-based RS setup and spectral reconstruction results

Figure 3. The axicon-based RS is applied for spectral measurements. a, Experimental setup of the axicon-based RS. SC: supercontinuum; AOTF: acousto-optic tunable filter; BE: beam expander. b, Observed intensity pattern corresponding to 1050 nm and 1700 nm. Simulated and observed 1D intensity profiles corresponding to c, 1050 nm and d, 1700 nm. e, Broadband spectral reconstruction spanning 1050–1700 nm. f, Comparison between the recovered peak wavelengths and the input peak wavelengths measured by a commercial spectrometer. g, Reconstructed spectra with a step size of 2.9 nm. h, Reconstructed spectrum of an ASE light source. i, Measured intensity distributions after axicon modulation under 0° and 90° incident polarization states. j, Spectral reconstruction results under different incident polarization angles. k, The R2R^2 for peak wavelength reconstruction in broadband spectral measurement as a function of the incident polarization angle.

For the purpose of comparison, the produced spectra are incident onto both our RS and a commercial spectrometer, respectively. First, we demonstrate the wide operating bandwidth of the system. As illustrated in Figure 3e, effective reconstruction is realized across the range of 1050–1700 nm. While the slower spectral variation of the concentric intensity rings at shorter wavelengths (see Figure 2d) broadens the reconstructed peaks, it still allows for sufficiently indicative results across the wide range. We employ the coefficient of determination R2R^2 (see definition in Method), a widely adopted metric in the field of RS [10, 13, 40], to evaluate the agreement between the reconstructed central wavelength values and the wavelength values under test. The R2R^2 can be as high as 0.9999, as depicted in Figure 3f. The current operational bandwidth is primarily limited by the spectral response range of the detector array and the tunable wavelengths in our laboratory. Then, following the reported methods [17, 41], we evaluate the spectral resolution by sequentially injecting single-peak spectra with a tiny separation into our RS. As shown in Figure 3g, spectral peaks separated by 2.9 nm can be clearly distinguished, with the first zero point of one spectral line coinciding with the main maximum of the other, and their respective central positions are consistent with the measurements from a commercial spectrometer. This resolution is comparable to the state-of-the-art calibration-simplified RSs [31, 42], and could be improved in the future by employing higher resolution detector arrays. Moreover, the spectrum of an amplified spontaneous emission (ASE) source with an FWHM of 41 nm is reconstructed, and the resulting spectral shape closely matches the measurements obtained using a commercial spectrometer (see Figure 3h).

The axicon-based RS offers the advantage of low polarization sensitivity. In many other types of RSs, the core dispersive medium exhibits polarization-dependent response [9, 12, 19]. To ensure that the system measures only a single variable, i.e., the wavelength, it is necessary to control the incident light to a single linear polarization state [7, 8]. This constraint not only increases hardware complexity but also blocks a portion of the incident optical energy. The measured intensity profiles in Figure 3i demonstrate that the axicon is insensitive to the polarization state of the incident light. Spectral reconstruction results under different polarization angles show strong robustness, as illustrated in Figure 3j. Figure 3k shows the variation of the R2R^2 for spectral reconstruction with respect to polarization angle in broadband spectral measurements, indicating that reconstruction consistently maintains high accuracy (R2>0.9960R^2 > 0.9960).

We further demonstrate the practical application potential of the axicon-based RS in wavelength division multiplexing (WDM) communication. As schematized in Figure 4a, we employ multiple independently modulated light sources at discrete bands near 1 μm1\ \mu\mathrm{m}, 1.3 μm1.3\ \mu\mathrm{m}, and 1.6 μm1.6\ \mu\mathrm{m} as transmitters. These signals are coupled into our axicon-based system, and the modulated spectral distribution is retrieved. The proposed RS clearly distinguishes the original binary modulation information (see Figure 4b), and its broad operating range may enable application across various data transmission media [43, 44].

Application of the proposed RS in optical communication and encryption

Figure 4. Application of the proposed RS in optical communication and encryption. a, Diagram of the WDM optical communication system incorporating the axicon-based RS. b, The axicon-based RS demultiplexes the three-waveband WDM signals and decodes the original binary data streams. c, Schematic illustration of the axicon-based RS for optical encryption. d, Transmitted spectral pattern and its corresponding decryption result.

Moreover, the relationship between the observed intensity distribution and the incident spectra in the RS is non-intuitive. This property opens up the possibility of using our system for optical encryption. As shown in Figure 4c, at the encryption end, the plaintext (the pattern “NUDT”) is first projected into a spectral sequence. The sender (Alice) then sequentially generates these spectral slices and illuminates the axicon (see Method for details), which imposes phase modulation to produce the ciphertext (spectrum-dependent intensity patterns) on the sensor array. After recording the ciphertext and being authorized by Alice to acquire the spectral-spatial TM as well as the reconstruction algorithm, the receiver (Bob) can recover the time-evolving spectrum. Connecting these spectral slices decrypts the plaintext (the pattern “NUDT”). Figure 4d shows the encoded time-varying spectral sequence at the transmitter, and

Figure 4dFigure 2 presents the reconstructed spectrum at the decryption end. The structural similarity (SSIM) index is employed to evaluate the decryption results (see definition in Method). The SSIM between the decrypted and plaintext patterns attains a value of 0.9605, indicating high decryption quality.

We have demonstrated that, based on the computationally generated TM, spectra can be reconstructed by iteratively solving a system of linear equations. However, the equation-solving approach has certain limitations, such as insufficient real-time

capacity and degraded accuracy under low spatial sampling rates where the system of equations is severely underdetermined [45]. In applications such as broadband laser warning [46, 47], it is desirable to rapidly acquire indicative, though not necessarily highly precise, spectral information. Moreover, to facilitate flexible deployment of devices, it is essential to retrieve spectral information using a small number of detector units.

To this end, a neural network is employed in this study for the spectral decoding of the axicon RS. Unlike existing spectral decoding networks, which require experimentally acquired intensity samples and ground-truth spectral labels to provide training datasets [3, 4, 48, 49], we can conveniently produce numerous training data that closely matches the realistic system using the computer-generated TM. Specifically, a series of synthetic spectral labels λ\lambda are first generated and then mapped through the TM to obtain the corresponding I\mathbf{I}. A tiny fully-connected neural network is adopted for this task (architecture and training details are provided in Methods). The network trained on synthetic data is then tested on real-world data.

We first test wide-spectrum classification with the infrared camera operating at 33 frames per second (FPS), achieving an accuracy as high as 100%. When the detector frame rate is increased to 267 FPS, the classification accuracy drops to 92.5% due to the reduced signal-to-noise ratio (SNR) of the captured intensity distribution caused by shorter exposure time. Given that the single inference time of the neural network (approximately 0.1 ms) is far shorter than the exposure time per frame (3.75 ms), the spectral information can practically be acquired at a rate of 267 Hz.

The above tests are conducted using the complete horizontal intensity profile (i.e., N=164N = 164 pixels), within which some pixels may carry redundant information. Existing RS studies have employed heuristic methods, including uniform sampling [50] and local sampling [51], to find compressed subspaces of the raw measurements. The field still lacks a principled method for determining the most characterizing spatial features in spectral extraction.

Supplementary information

Supplementary information accompanies this paper.

Acknowledgements

The authors thank Mingkang Yuan and Haoyu Liu for valuable discussions and help on the video production.

Declarations

Funding

Innovation Research Foundation of National University of Defense Technology.

Conflict of interest

The authors declare no conflicts of interest.

Data availability

Data underlying the results presented in this paper are not publicly available at this time but may be obtained from the authors upon reasonable request.

Code availability

Not applicable.

Author contributions

J.L. conceived the idea and designed the experiments. Z.H. and Y.G. performed the numerical simulations. J. Ye and Y.K. contributed to the experimental setup. J. Li, J. Xu, J. Leng, and P.Z. supervised the project. All authors discussed the results and contributed to the manuscript.

References

  1. [1]Zhang, Y., Yang, E., Yoon, H.H., Cheng, Q., Sun, Z., Hasan, T., Cai, W.: Reconstructive spectrometers: hardware miniaturization and computational reconstruction. eLight 5(23), 1–24 (2025)
  2. [2]Yao, C., Ma, J., Wang, N., Bao, P., Zhuo, W., Zhang, T., Zhang, W., Xu, K., Yan, T., Ming, L., Ye, Y., Hasan, T., White, I., Penty, R., Cheng, Q.: Optical convolutional spectrometer. Nat. Photonics 20(1), 100–108 (2026)DOI
  3. [3]Ahamed, A., Myat, H., Rawat, A., McPhillips, L.N., Islam, M.S.: AI-augmented photon-trapping spectrometer-on-a-chip on silicon platform with extended near-infrared sensitivity. Adv. Photonics 8(1), 253–267 (2026)
  4. [4]Saetchnikov, I., Tcherniavskaia, E., Ostendorf, A., Saetchnikov, A.: Mode splitting in optical microcavities for speckle-free wavelength reconstruction. Light Sci. Appl. 15(1), 176–184 (2026)DOI
  5. [5]Shi, Y., Chen, Y., Zhang, G., Cui, H., Wang, P., Fan, J., Xiang, R., Ju, B., Jin, L., Yang, Z.: Dynamic multi-FSR encoding for computational hyperspectral imaging. Photonix 7(1), 1–12 (2026)DOI
  6. [6]Qiu, J., Liu, T., Xiang, C., Yu, T., Liu, Q., Xiao, S.: Integrated spectropolarimeter by metasurface-based diffractive optical networks. Optica 13(4), 737–744 (2026)
  7. [7]Cen, Q., Pian, S., Liu, X., Tang, Y., He, X., Ma, Y.: Microtaper leaky-mode spectrometer with picometer resolution. eLight 3(1), 9 (2023)
  8. [8]Cao, H., Čižmár, T., Turtaev, S., Tyc, T., Rotter, S.: Controlling light propagation in multimode fibers for imaging, spectroscopy, and beyond. Adv. Opt. Photon. 15(2), 524–612 (2023)DOI
  9. [9]Facchin, M., Khan, S.N., Dholakia, K., Bruce, G.D.: Determining intrinsic sensitivity and the role of multiple scattering in speckle metrology. Nat. Rev. Phys. 6(8), 500–508 (2024)DOI
  10. [10]Xu, H., Qin, Y., Hu, G., Tsang, H.K.: Cavity-enhanced scalable integrated temporal random-speckle spectrometry. Optica 10(9), 1177–1188 (2023)
  11. [11]Redding, B., Liew, S.F., Sarma, R., Cao, H.: Compact spectrometer based on a disordered photonic chip. Nat. Photonics 7(9), 746–751 (2013)DOI
  12. [12]Gu, Z., Zhang, W., Yu, Y., Zhang, X.: Disordered-guiding photonic chip enabled high-dimensional light field detection. Nat. Commun. 16(1), 7741 (2025)DOI
  13. [13]Gao, Z., Jiang, T., Zhang, M., Xiong, Y., Wu, H., Tang, M.: Breaking the speed limitation of wavemeter through spectra-space-time mapping. Light Adv. Manuf. 5(1), 1–8 (2024)DOI
  14. [14]Liang, J., Li, J., Huang, Z., He, J., Guo, Y., Ma, X., Ke, Y., Ye, J., Xu, J., Leng, J., Zhou, P.: High-resolution miniaturized speckle spectrometry using fuse-induced fiber microvoids. Photonics Res. 13(9), 2654–2667 (2025)
  15. [15]Zhang, Z., Xiao, S., Song, Q., Xu, K.: Scalable on-chip diffractive speckle spectrometer with high spectral channel density. Light Sci. Appl. 14(5), 1324–1333 (2025)DOI
  16. [16]Zhang, Z., Song, Q., Xiao, S., Xu, K.: Single-shot on-chip diffractive speckle spectrometer with high spectral channel density. Laser Photonics Rev. 19(9), 2401987 (2025)DOI
  17. [17]Wan, Y., Fan, X., Xu, B., He, Z.: Reconstructive spectrum analyzer with high-resolution and large-bandwidth using physical-model and data-driven model combined neural network. Laser Photonics Rev. 17(7), 1–9 (2023)
  18. [18]Metzger, N.K., Spesyvtsev, R., Bruce, G.D., Miller, B., Maker, G.T., Malcolm, G., Mazilu, M., Dholakia, K.: Harnessing speckle for a sub-femtometre resolved broadband wavemeter and laser stabilization. Nat. Commun. 8(1), 15610 (2017)
  19. [19]Zhu, S., Zheng, Z., Meng, W., Chang, S., Tan, Y., Chen, L., Fang, X., Gu, M., Chen, J.: Harnessing disordered photonics via multi-task learning towards intelligent four-dimensional light field sensors. Photonix 4(1), 1–14 (2023)
  20. [20]Liang, J., Ye, J., Ke, Y., Zhang, Y., Ma, X., He, J., Li, J., Xu, J., Leng, J., Zhou, P.: Polarization transmission matrix enabled high-accuracy, large-bandwidth speckle-based reconstructive spectrometer. Appl. Phys. Lett. 124(7), 071111 (2024)
  21. [21]Chen, H., Duan, Z., Guan, C., Li, X., Gao, S., Hu, X., Ye, P., Yang, J., Li, P., Shi, J., Yuan, L.: High-resolution compact spectrometer based on periodic tapered coreless fiber. Opt. Lett. 48(17), 4574–4577 (2023)DOI
  22. [22]Wang, T., Li, Y., Xu, B., Mao, B., Qiu, Y., Meng, Y.: High-resolution wavemeter based on polarization modulation of fiber speckles. APL Photonics 5(12), 126101 (2020)DOI
  23. [23]Shen, C., Pan, T., Wei, Y., Zhu, S., Xu, Y., Li, A., Chen, H., Chen, J.: Intelligent optical fiber-integrated near-infrared polarimeter based on upconversion nanoparticles. Adv. Opt. Mater. 11(22), 2301259 (2023)DOI
  24. [24]Zheng, Z., Zhu, S., Chen, Y., Chen, H., Chen, J.: Towards integrated mode-division demultiplexing spectrometer by deep learning. Opto-Electron. Sci. 1(11), 220012–2 (2022)DOI
  25. [25]Chen, Q., Nie, H., Liu, Q., Tan, N., Tuo, Z., Yan, J., Wen, L.: Metasurface-engineered thermal emitters enabled chip-scale mid-infrared spectroscopic sensing. PhotoniX 6(1), 1–14 (2025)DOI
  26. [26]Liang, J., Xu, J., Ke, Y., Li, S., He, J., Guo, Y., Zhang, Y., Ma, X., Ye, J., Li, X., Leng, J., Zhou, P.: Spectral programmable mid-infrared optical parametric oscillator. Photonics Res. 12(8), 1593–1603 (2024)DOI
  27. [27]Mazilu, M., Vettenburg, T., Falco, A.D., Dholakia, K.: Random super-prism wavelength meter. Opt. Lett. 39(1), 96–99 (2014)
  28. [28]Liang, J., Qi, Y., Huang, Z., Ye, J., Xu, J., Li, J., Leng, J., Zhou, P.: Super-resolution speckle wavemeter enabled by a tiny convolutional neural network. Opt. Lett. 50(17), 5266–5269 (2025)DOI
  29. [29]Sharma, N., Khare, K., Gupta, S.: Determining the transfer function of a reconstructive spectrometer using measurements at two wavelengths. Opt. Lett. 48(14), 3753–3756 (2023)DOI
  30. [30]Sharma, N., Kumar, G.R., Garg, V., Mote, R.G., Gupta, S.: Reconstructive spectrometer using a photonic crystal cavity. Opt. Express 29(17), 2665–26657 (2021)DOI
  31. [31]Chen, C., Gu, H., Liu, S.: Ultra-simplified diffraction-based computational spectrometer. Light Sci. Appl. 13(6), 1022–1031 (2024)DOI
  32. [32]Tobin, M.S.: Introduction to Fourier optics (book). Am. Sci. 85(6), 581 (1997)
  33. [33]Latychevskaia, T., Longchamp, J.N., Fink, H.W.: When holography meets coherent diffraction imaging. Opt. Express 20(27), 28871–28892 (2012)
  34. [34]Reddy, I.V.A.K., Bertoncini, A., Liberale, C.: 3D-printed fiber-based zeroth- and high-order Bessel beam generator. Optica 9(6), 645 (2022)
  35. [35]Liu, Y., Zhang, D., Li, W., Zheng, S., Fan, H., Lan, T., Hao, Q., Huang, Y.: Side-viewing axicon-integrated miniature fiber probe for extended depth of focus and ultrahigh lateral resolution endoscopic imaging. Microsyst. Nanoeng. 11(1), 235 (2025)DOI
  36. [36]Xiaoxue, C., Lou, Y., Li, C., Dai, M., Sun, Q.: Analysis of characteristics of a beam transformed by an axicon. Laser Optoelectron. Prog. 58(17), 1705001 (2021)
  37. [37]Elsharkawi, A.S.A., Lo, Y.L.: Flattop axial Bessel beam propagation with analytical form of the phase retardation function. Opt. Lett. 49(19), 5403 (2024)DOI
  38. [38]Elsharkawi, A.S.A., Tsai, I.C., Lin, X.T., Chang, C.Y., Lo, Y.L.: Bessel beam propagation using radial beam propagation method at different propagation scales. Opt. Express 32(17), 30242 (2024)DOI
  39. [39]Liang, J., Li, J., He, J., Guo, Y., Ma, X., Zhang, Y., Ke, Y., Ye, J., Xu, J., Leng, J., Zhou, P.: Multi-wavelength spectral reconstruction with localized speckle pattern. Opt. Commun. 575, 131266 (2025)DOI
  40. [40]Zhang, Y., Albrow-Owen, T., Zhao, Z., Chen, Y., Zhao, Y., Joyce, H., Hasan, T., Yang, Z., Su, Y., Guo, X.: Miniaturized disordered photonic molecule spectrometer. Light Sci. Appl. 14(1), 144 (2025)DOI
  41. [41]Tua, D., Liu, R., Yang, W., Zhou, L., Song, H., Ying, L., Gan, Q.: Imaging-based intelligent spectrometer on a plasmonic rainbow chip. Nat. Commun. 14(1), 1902 (2023)DOI
  42. [42]Lee, D., Song, G., Lee, C., Lee, C., Jang, M.: Reconstructive spectrometer using double-layer disordered metasurfaces. Sci. Adv. 11(22), 2376 (2025)DOI
  43. [43]Koizumi, K., Yoshida, M., Hirooka, T., Nakazawa, M.: 10 Gbit/s photonic crystal fiber transmissions with 1.1 μm directly modulated single mode VCSEL. In: Optical Fiber Communication Conference, pp. 1–3. Optica Publishing Group, Washington, D.C. (2010)
  44. [44]Zhu, M., Huang, F., Liu, D., Wang, W., Gao, A., Zhao, W., Zhao, S., Lian, D., Gao, C., Yu, Z., Dai, D.: An 8 × 200 Gbps wavelength-division multiplexing transmitter using lithium tantalate. Photonix 6(1), 27 (2025)DOI
  45. [45]Yao, C., Xu, K., Zhang, W., Chen, M., Cheng, Q., Penty, R.: Integrated reconstructive spectrometer with programmable photonic circuits. Nat. Commun. 14(1), 6376 (2023)DOI
  46. [46]Zhang, R., Yang, X., Shi, J., Wu, Q., Wang, Z., Li, M.: Integrated optical system design for large-field-of-view and broad-spectrum laser warning. Appl. Opt. 61(14), 4187–4194 (2022)DOI
  47. [47]Wang, L., Dong, H., Zhang, W., Shen, X.: Optimum design of wide angle laser detecting system based on fish eye lens and sinusoidal amplitude grating. Opt. Commun. 310, 173–178 (2014)DOI
  48. [48]Li, X., Wang, J., Yu, F., Chen, J., Chen, X., Lu, W., Li, G.: Nonlinear memristive computational spectrometer. Light Sci. Appl. 14(1) (2025)DOI
  49. [49]Du, X., Wang, Y., Cui, Y., Rao, G., Huang, J., Chen, X., Zhou, T., Wu, C., Yang, Z., Cui, H., Zhao, Y., Xiong, J.: A microspectrometer with dual-signal spectral reconstruction. Nat. Electron. 7(11), 984–990 (2024)DOI
  50. [50]Redding, B., Cao, H.: Using a multimode fiber as a high-resolution, low-loss spectrometer. Opt. Lett. 37(16), 3384–3386 (2012)
  51. [51]Wang, J., Zhang, F., Zhou, X., Shen, X., Niu, Q., Yang, T.: Miniaturized spectrometer based on MLP neural networks and a frosted glass encoder. Opt. Express 32(17), 30632 (2024)DOI

Paper details

vlnc:W_zwft7yma
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 0

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents