WorksPhysics and Astronomy
Numerical simulation of microscale acoustic streaming flow
Abstract
The efficient mixing of fluid samples in miniaturized total analysis systems is essential for numerous applications including biological screening assays, chemical extraction, polymerization, cell analysis, and protein folding. Miniaturized microfluidic platforms have recently emerged for microscale fluid mixing with their capabilities of high-throughput sample processing and reduced sample depletion. However, microscale fluid mixing is inherently hampered due to the characteristics of a low Reynolds number flows in diminutive channels. Microscale fluid mixing mainly depends on molecular diffusion and thus requires long processing time. In order to address the conundrum, a variety of active microfluidic approaches for swift and efficient mixing have been developed using electro-kinetic flow, laser-induced flow, magnetic stirring, and acoustic streaming flow (ASF). Among these techniques with external force fields, acoustofluidic fluid mixing has been acclaimed due to its on-demand, controllable, non-invasive and biocompatible nature. In this study, we performed numerical simulations of acoustic streaming flows, induced by with a highly localized surface acoustic waves (SAWs), in a microscale fluidic channel based on an acoustic wave attenuation model
Introduction
The efficient mixing of fluid samples in miniaturized total analysis systems is essential for numerous applications[1] including biological screening assays[2], chemical extraction[3], polymerization[4], cell analysis and protein folding.[5] Miniaturized microfluidic platforms have recently emerged for microscale fluid mixing with their capabilities of high-throughput sample processing and reduced sample depletion.[6] However, microscale fluid mixing is inherently hampered due to the characteristics of low Reynolds number flows in diminutive channels. Microscale fluid mixing mainly depends on molecular diffusion and thus requires long processing time. In order to address the conundrum, a variety of active microfluidic approaches for swift and efficient mixing have been developed using electro-kinetic flow,[7, 8] laser-induced flow,[9] magnetic stirring,[10] and acoustic streaming flow (ASF).[11, 12] Among these techniques with external force fields, acoustofluidic fluid mixing has been acclaimed due to its on-demand, controllable, non-invasive and biocompatible nature. In this study, we performed numerical simulations of acoustic streaming flows, induced by with a highly localized surface acoustic waves (SAWs), in a microscale fluidic channel based on an acoustic wave attenuation model.
Methods
For numerical simulations of 3D microscale flows interacted with acoustic waves, COMSOL Multiphysics was utilized to model the effected fluid streamlines in the proximity of focused SAWs. The non-linear time-averaged body force and SAW attenuation model for the substrate/fluid interface and fluid domain are also considered. The attenuation lengths were analytically determined by using parametric relations and for the substrate/fluid interface and within the fluid itself, respectively[13] where is the coefficient of attenuation in substrate, is wavelength of applied surface acoustic wave and is coefficient of attenuation in fluid media. The effect of high-frequency SAWs originated from a focused interdigital transducer (FIDT) on the flow streamlines was numerically calculated in our numerical model. The grid independence was also confirmed by eliminating the influence of mesh parameters on the simulated acoustic velocities and streaming velocities in the laminar flow frequency domain to avoid any numerical error arising from grid convergence.
The COMSOL laminar flow model started with the definition of constant and variable parameters in both local and global domains. The significant constant parameters were defined globally for all physics while simulating the problem through a fully coupled scheme. The rest of the variables were manipulated in the extended definition step of each module separately to make it accessible for the respective model.
Analytical expressions of the attenuation coefficients for the substrate/fluid and fluid medium are given by
Where , , , and indicate density, speed of sound, wavelength, and angular frequency, respectively (subscript and indicate fluid and substrate). The parameter is a function of the dynamic and bulk viscosities. The above relations predict the length of an attenuated SAWs in the fluid/substrate domain, which has a direct relation with the frequency of applied waves. In second equation, the coefficient provides depreciated distance of leaky waves in a fluid, where the attenuation is the square of the applied acoustic wave frequency.
For domain definition, the 3D domain was built by using a geometric tool with a dimension of 550 80 650 in width, height and length of the microchannel. The width between the unsymmetrical vortices was approximately the width of the acoustic beam, which scaled with the aperture of a FIDT. The body force was calculated in the volumetric domain using the given relation
Where is the first order fluid displacement velocity magnitude in the orthogonal direction to the fluid flow. Also, the velocity magnitude in the fluid was analytically determined by , where represents the overall attenuation in the substrate and fluid up to the first-order term while the rest of higher-order terms with reflection coefficient were terminated to avert complexity where . The and in the above relation are acoustic impedance values of the fluid/microchannel ceiling and fluid/substrate interfaces, and the acoustic impedance was calculated . The analytical expression of the overall attenuation coefficient can be given as
where is the attenuation function that includes both the attenuation in substrate and fluid as well as the angle of refraction when a surface acoustic wave enters in a fluid at a certain angle which is . The is initial displacement of SAWs, which was experimentally determined by laser Doppler velocimetry and particles image velocimetry. The first-order reduced attenuation function can be given as
The laminar flow physics was adopted to include fluid properties, Dirichlet boundary conditions for inlet velocity and outlet pressure, no-slip boundary condition, volumetric forces and incompressibility of fluid. Along with fluid flows, the trajectories of submicron particles under strong acoustic streaming effect was also simulated by using the particle tracing module.
Results and discussion
The magnitude of the time-averaged body force was directly related to the square of the acoustic velocity and attenuation coefficients. The numerical results show effective streaming in the fluid regime as compared to the fluid/substrate portion because the attenuation coefficient in fluid is the square of the frequency of the SAWs while it only correlates with unit power of frequency in the substrate.
As shown in Figure 1, the disturbance in flow streamlines was clearly observed as the ASFs become dominant over the lateral flow velocity. The simulated streamlines were plotted for increasing body force within the proximity of 11.4 wavelength and 129.5 MHz acoustic waves acting orthogonal to a 3 mm/s (averaged) lateral flow in 550 wide microchannel. A dimensionless parameter was introduce to represent the ratio of the time-averaged second-order streaming velocity () to the lateral inflow velocity (). This specific parameter indicates the effectiveness of acoustic streaming in the fluid regime with applied SAWs. The increasing body force and streaming in the microchannel resulted in increasing value of in comparison with constant inflow velocity due to gradually elevated input power or acoustic wave amplitude as . In Figure 1(a), the effects of ASFs in the fluid streamlines was insignificant due to the small substrate velocity () of the orthogonally applied acoustic beam. In Figure 1(b-Figure 1d), in contrast, the prominent ASF-induced vortices were gradually developed due to the strong body force with increasing . We found that the deflection of the flow streamlines due to the ASF-induced microscale vortices and resultant flow mixing were directly dependent on the amplitude of the acoustic field. It was also confirmed that the wave attenuation in the fluid as well as in the substrate, which in turn determined the size of the microscale vortices, was strongly correlated with the acoustic wavelength.
Figure 1. Flow patterns in the vicinity of high frequency travelling surface acoustic waves placed orthogonal to the fluid flow direction. , where value of increases the streaming velocity dominates over inlet velocity of fluid, thus streaming effect becomes significant for efficacious mixing of sample in microchannel. (a) Streaming effect is not prominent as (b) Gradual increase in acoustic velocity results in minor diversion of inlet streamlines where (c) and (d) represents the strong streaming effect where and 11.83 respectively.
Conclusion
In the present study, we conducted numerical simulations of ASF-induced flow mixing by highly localized SAWs. We observed efficient ASFs in the microchannel to achieve efficient on-chip flow mixing in the microchannel. The results of numerical simulation advocate the effective mixing at microscale through acoustic attenuation of high-frequency
SAWs generated from a FIDT.
Acknowledgement
This work was supported by a National Research Foundation of Korea (NRF) grant (No. 2019022966) and the KUSTAR-KAIST Institute.
References
- [1]G. S. Jeong, S. Chung, C. B. Kim, and S. H. Lee, “Applications of micromixing technology,” Analyst, vol. 135, no. 3, pp. 460–473, 2010.DOI
- [2]P. S. Dittrich, M. Jahnz, and P. Schwille, “A new embedded process for compartmentalized cell-free protein expression and on-line detection in microfluidic devices,” ChemBioChem, vol. 6, no. 5, pp. 811–814, 2005.pubmed.ncbi.nlm.nih.gov/15827950
- [3]K.-S. Yun and E. Yoon, “Microfluidic components and bio-reactors for miniaturized bio-chip applications,” Biotechnol. Bioprocess Eng., vol. 9, no. 2, pp. 86–92, 2004.DOI
- [4]C. Rosenfeld, C. Serra, C. Brochon, and G. Hadziioannou, “Influence of micromixer characteristics on polydispersity index of block copolymers synthesized in continuous flow microreactors,” Lab Chip, vol. 8, no. 10, pp. 1682–1687, 2008.DOI
- [5]Ben Eshaya, E., Hazan, G., Rahamim, D., Amir, E., & Haas, A. (2012). An instrument for fast acquisition of fluorescence decay curves at picosecond resolution designed for ‘double kinetics’ experiments: Application to fluorescence resonance excitation energy transfer study of protein folding. Rev. Sci. Instrum., 83(8), 84301.
- [6]C. Wyatt Shields IV, C. D. Reyes, and G. P. López, “Microfluidic cell sorting: a review of the advances in the separation of cells from debulking to rare cell isolation,” Lab Chip, vol. 15, no. 5, pp. 1230–1249, 2015.DOI
- [7]C. Y. Lim, Y. C. Lam, and C. Yang, “Mixing enhancement in microfluidic channel with a constriction under periodic electro-osmotic flow,” Biomicrofluidics, vol. 4, no. 1, p. 14101, Jan. 2010.DOI
- [8]C.-K. Chen and C.-C. Cho, “Electrokinetically driven flow mixing utilizing chaotic electric fields,” Microfluid. Nanofluidics, vol. 5, no. 6, pp. 785–793, 2008.DOI
- [9]Hellman, A. N., & al., . et . (2007). Laser-Induced Mixing in Microfluidic Channels. Anal. Chem., 79(12), 4484–4492.
- [10]Wang, Y., Zhe, J., Chung, B. T. F., & Dutta, P. (2008). A rapid magnetic particle driven micromixer. Microfluid. Nanofluidics, 4(5), 375–389.
- [11]W.-K. Tseng, J.-L. Lin, W.-C. Sung, S.-H. Chen, and G.-B. Lee, “Active micro-mixers using surface acoustic waves on Y-cut 128° LiNbO3,” J. Micromechanics Microengineering, vol. 16, no. 5, pp. 539–548, 2006.DOI
- [12]Zeng, Q., & al., . et . (2011). Milliseconds mixing in microfluidic channel using focused surface acoustic wave. Sensors Actuators B Chem., 160(1), 1552–1556.
- [13]D. J. Collins, Z. Ma, and Y. Ai, “Highly Localized Acoustic Streaming and Size-Selective Submicrometer Particle Concentration Using High Frequency Microscale Focused Acoustic Fields,” Anal. Chem., vol. 88, no. 10, pp. 5513–5522, May 2016.DOI