betaFeedback

WorksPhysics and Astronomy

Precise 136^{136}Xe Double Beta Decay Measurement in PandaX-4T with Implications on the Nuclear Matrix Elements and Majorons

Abstract

The continuous spectrum of double beta decay (ββββ) provides a sensitive probe to test the predictions of the standard model and to search for signatures of new physics beyond it. We present a comprehensive analysis of the 136^{136}Xe ββββ spectrum utilizing 39.1±0.7 kg⋅yr39.1 \pm 0.7~\textrm{kg}\cdot\textrm{yr} of 136^{136}Xe exposure from the PandaX-4T experiment. The analysis yields the most precise measurement to date of the 136^{136}Xe two-neutrino double beta decay (2νββ2νββ) half-life, (2.14±0.05)×1021(2.14 \pm 0.05) \times 10^{21} years, the uncertainty of which is reduced by a factor of 2 compared to our previous result. We measure the parameter ξ312νξ_{31}^{2ν}, defined as the ratio between the subleading and leading components of the 136^{136}Xe 2νββ2νββ nuclear matrix element, to be 0.59−0.38+0.410.59^{+0.41}_{-0.38}, which is consistent with theoretical predictions. We also search for Majoron-emitting modes of 136^{136}Xe ββββ, establishing the most stringent limit for the spectral index n=7n=7.

(PandaX Collaboration)

27{}^{27}Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China

28{}^{28}School of Nuclear Science and Technology, University of Chinese Academy of Sciences, Beijing 100049, China

29{}^{29}Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China

30{}^{30}School of Physical Sciences, University of Chinese Academy of Sciences, Beijing 100049, China

Double beta decay (ββ\beta\beta) is a rare nuclear process [1]. If two neutrinos are emitted during this process (2νββ2\nu\beta\beta), it is consistent with the electroweak interaction framework of the standard model of particle physics. In contrast, if no neutrinos are emitted, the process is referred to as neutrinoless double beta decay (0νββ0\nu\beta\beta), which can occur only if neutrinos are Majorana particles [2, 3, 4, 5]. Additionally, if one or two bosons are emitted in ββ\beta\beta processes, they are typically referred to as “Majorons” [6, 7, 8]. Although 2νββ2\nu\beta\beta has been experimentally observed and measured in several studies, such as those involving 136Xe{}^{136}\mathrm{Xe} [9, 10, 11, 12], neither 0νββ0\nu\beta\beta nor Majoron-emitting ββ\beta\beta has been detected.

Recent experiments have established the most stringent lower limits on the 0νββ0\nu\beta\beta half-life of different isotopes, such as 136Xe{}^{136}\mathrm{Xe} [13, 14], 76Ge{}^{76}\mathrm{Ge} [15, 16, 17, 18], and 130Te{}^{130}\mathrm{Te} [19]. The 0νββ0\nu\beta\beta half-life is linked to the effective Majorana neutrino mass mββm_{\beta\beta} by [5]

(T1/20ν)−1=∣mββ∣2me2gA4∣M0ν∣2G0ν,(1)\left(T_{1/2}^{0\nu}\right)^{-1} = \frac{\lvert m_{\beta\beta}\rvert^2}{m_e^2}g_A^4\lvert M^{0\nu}\rvert^2G^{0\nu}, \tag*{(1)}

where mem_e is the electron mass, gAg_A the axial-vector coupling constant, M0νM^{0\nu} the nuclear matrix element (NME), and G0νG^{0\nu} the phase space factor. The current understanding of 0νββ0\nu\beta\beta NME remains incomplete, with significant discrepancies observed in different nuclear many-body approaches and potential influences of quenching effects [20, 21]. Since 2νββ2\nu\beta\beta and 0νββ0\nu\beta\beta share the same initial and final nuclear states, accurately determining 2νββ2\nu\beta\beta NME is essential to constrain 0νββ0\nu\beta\beta NME predictions [22]. A refined expression for the 2νββ2\nu\beta\beta half-life, retaining terms up to second order in the Taylor expansion, is presented as follows [22]:

(T1/22ν)−1=(gAeff)4∣MGT2ν∣2(G02ν+ξ312νG22ν),(2)\left(T_{1/2}^{2\nu}\right)^{-1} = \left(g_A^{\mathrm{eff}}\right)^4\lvert M_{\mathrm{GT}}^{2\nu}\rvert^2\left(G_0^{2\nu}+\xi_{31}^{2\nu}G_2^{2\nu}\right), \tag*{(2)}

where gAeffg_A^{\mathrm{eff}} is the effective axial-vector coupling constant and MGT2νM_{\mathrm{GT}}^{2\nu} denotes the leading-order Gamow-Teller component of the NME. In contrast to the standard phase space factor G02νG_0^{2\nu}, the phase space factor G22νG_2^{2\nu} accounts for the dependence on lepton energies of the energy denominators of NMEs. The parameter ξ312ν\xi_{31}^{2\nu} is defined as

ξ312ν=MGT−32ν/MGT2ν\xi_{31}^{2\nu}=M_{\mathrm{GT}-3}^{2\nu}/M_{\mathrm{GT}}^{2\nu}, where the subleading NME MGT−32νM_{\mathrm{GT}-3}^{2\nu} is sensitive only to contributions from the lightest states of the intermediate nucleus, while the NME MGT2νM_{\mathrm{GT}}^{2\nu} is also sensitive to higher-lying states. The experimentally accessible parameter ξ312ν\xi_{31}^{2\nu}, which can be measured through electron energy spectrum fits, allows for the discrimination between different theoretical models, and thus, provides new insights into 0νββ0\nu\beta\beta NME calculations. Specifically, a zero (nonzero) value of ξ312ν\xi_{31}^{2\nu} implies the higher (single) state dominance hypothesis of 2νββ2\nu\beta\beta [22].

Majorons are potential dark matter candidates and play roles in various cosmological and astrophysical processes [23, 24, 25]. The Majoron-emitting ββ\beta\beta encompasses a range of modes, which are distinguished by the number of emitted bosons, the leptonic charge, whether lepton number is violated, and whether the Majoron is a Goldstone boson. Different modes may produce identical summed electron energy spectra, which are classified into four types based on the spectral index n=1n = 1, 2, 3, and 7 [26, 27]. Previous experimental searches have established stringent constraints on these processes with 136Xe{}^{136}\mathrm{Xe} [28, 29].

Previous measurements of ξ312ν\xi_{31}^{2\nu} and searches for Majoron-emitting ββ\beta\beta of 136Xe{}^{136}\mathrm{Xe} have been limited to relatively high energy thresholds, specifically between 500 keV and 800 keV [10, 28, 29]. Consequently, the lower energy region remains completely unexplored. The PandaX-4T detector, which uses a natural xenon target and was initially designed for dark matter searches in the low-energy region, has expanded its detection capability to the MeV range [12, 30]. In this Letter, we leverage the nearly complete ββ\beta\beta spectrum to perform the measurement of ξ312ν\xi_{31}^{2\nu} and the searches for Majoron-emitting modes of ββ\beta\beta of 136Xe{}^{136}\mathrm{Xe}, using a dataset of the commissioning run (Run0, 94.8 days of live time) and the first science run (Run1, 163.5 days) of the PandaX-4T experiment [30, 31, 32] with a total 136Xe{}^{136}\mathrm{Xe} exposure of 39.1 ±\pm 0.7 kg · yr. The energy region of interest (ROI) for the spectrum is from 20 keV to 2800 keV.

The PandaX-4T detector is a dual-phase time projection chamber (TPC) containing 3.7 tons of natural xenon in its active volume. The TPC has a vertical height of 1.185 m and is enclosed by a field cage along its lateral surfaces. The lateral surfaces of the TPC are lined with reflective Teflon panels, arranged in a regular 24-sided polygon with an inscribed diameter of 1.185 m. Three electrode grids (cathode, gate, and anode) are vertically stacked within the TPC to generate a drift field and an extraction field. Two arrays of 3-inch Hamamatsu photomultiplier tubes (PMTs) are placed on the top and bottom as photosensors. A more detailed description of the detector can be found in Ref. [33].

Energy deposition in liquid xenon (LXe) produces a prompt scintillation signal (S1S1) and ionization electrons. These electrons drift upward into the gaseous xenon phase, where they generate a delayed electroluminescence signal (S2S2) via proportional scintillation. Energy reconstruction utilizes the charge of S1S1 and S2BS2_B, where S2BS2_B stands for S2S2 detected by the bottom PMT array, following the procedure detailed in Ref. [30, 32, 34, 35]. Spatial reconstruction determines the vertical (zz-axis) position via drift velocity and the time delay between the S1S1 and S2S2 signals, while the horizontal (xx- and yy-axes) coordinates are obtained through maximum likelihood estimation of the charge distribution pattern of S2S2 observed in the top PMT array [32].

The data production and event selection procedures follow those described in Refs. [30, 32, 34, 35]. The fiducial volume (FV) from the previous study [32], defined as the innermost, cleanest part of the detector, is adopted in this analysis. The fiducial mass is determined to be 625 ±\pm 10 kg for Run0 and 621 ±\pm 13 kg for Run1, by scaling the ratio of 83Kr^{83}\mathrm{Kr} events in the FV and in the whole TPC. The uncertainty arises from the LXe density and the difference between the geometrically calculated volume and the volume scaled by the uniformly distributed 83Kr^{83}\mathrm{Kr} calibration source [32].

Compared with our previous study of the 136Xe^{136}\mathrm{Xe} 2νββ2\nu\beta\beta decay [12], the present analysis extends the analysis window down to 20 keV. Similar to Ref. [32], monoenergetic peaks at 41.5 keV (from 83Kr^{83}\mathrm{Kr}), 164 keV (131Xe^{131}\mathrm{Xe}), and 236 keV (127Xe^{127}\mathrm{Xe} and 129Xe^{129}\mathrm{Xe}) are used for energy calibration, together with high-energy peaks from 137Cs^{137}\mathrm{Cs}, 60Co^{60}\mathrm{Co}, 40K^{40}\mathrm{K}, and the 232Th^{232}\mathrm{Th} decay chain. The energy response is modeled using five parameters, which account for a possible shift between the reconstructed and true energies as well as the energy resolution [32]. The energy resolution is parametrized by a Gaussian function with a width σ(E)\sigma(E) given by

σ(E)E=aE+bE+c\frac{\sigma(E)}{E} = \frac{a}{\sqrt{E}} + bE + c

where EE is the reconstructed energy in keV. The residual energy nonlinearity is modeled as E=dE^+eE = d\hat{E} + e, where E^\hat{E} denotes the true energy. The calibrated parameter values and their uncertainties, Min=(ain,bin,cin,din,ein)\mathcal{M}_{\mathrm{in}} = (a_{\mathrm{in}}, b_{\mathrm{in}}, c_{\mathrm{in}}, d_{\mathrm{in}}, e_{\mathrm{in}}) (Table I), together with the corresponding 5×55 \times5 covariance matrix Σ\Sigma, are used to fit the Run0 and Run1 data independently. Due to the lack of sufficient high-energy calibration data within the fiducial volume, the energy response model is derived from physics data in a control region outside the FV, providing a closely matched but statistically uncorrelated dataset for the final fit [30].

SourcesRun0 (94.8 d)Run1 (163.5 d)
Detector response
aina_{\mathrm{in}} [keV]0.41±0.020.41 \pm0.020.37±0.110.37 \pm0.11
binb_{\mathrm{in}} [keV−1^{-1}](5±1)×10−6(5 \pm1) \times10^{-6}(3±2)×10−6(3 \pm2) \times10^{-6}
cinc_{\mathrm{in}}(4±20)×10−4(4 \pm20) \times10^{-4}(9±6)×10−3(9 \pm6) \times10^{-3}
dind_{\mathrm{in}}1.0000±0.00061.0000 \pm0.00061.0005±0.00061.0005 \pm0.0006
eine_{\mathrm{in}} [keV](0.52±0.11)(0.52 \pm0.11)(−3.12±0.75)(-3.12 \pm0.75)
Overall efficiency
SS fraction (2νββ2\nu\beta\beta)(98±9)%(98 \pm9)\%(98±10)%(98 \pm10)\%
Quality cut(99.84±0.03)%(99.84 \pm0.03)\%(99.72±0.11)%(99.72 \pm0.11)\%
Signal selection
LXe density [g/cm3^3]2.850 ±\pm 0.004
136Xe^{136}\mathrm{Xe} abundance(8.584±0.114)%(8.584 \pm0.114)\%
FV mass [kg]625 ±\pm 10621 ±\pm 13

Table I. Summary of sources of systematic uncertainties. Min\mathcal{M}_{\mathrm{in}} denotes the 5-parameter detector response model (see text), with its means and uncertainties determined from monoenergetic peaks obtained from the control data outside of the FV.

The total detection efficiency comprises three components: the single-site (SS) fraction, quality cut (QC) efficiency, and ROI acceptance, estimated with methods inherited from Ref. [32] and summarized in Table I. The SS fraction is defined as the ratio of SS to the sum of SS and multisite (MS) energy deposition events in the detector. We validate the SS fraction within the ROI using 232Th^{232}\mathrm{Th} calibration data together with 232Th^{232}\mathrm{Th} events simulated with the BambooMC simulation framework [36]. In this analysis, the QC efficiencies of Run0 and Run1 are (99.84±0.03)%(99.84 \pm0.03)\% and (99.72±0.11)%(99.72 \pm0.11)\%, respectively.

To generate the signal spectra for the ξ312ν\xi^{2\nu}_{31} fit, the theoretical spectra of the first and second terms of the Taylor expansion in Eq. (2) are calculated from the numerical wave functions, which are the solutions of the Dirac equation [37], obtained with the package RADIAL [38] by assuming a uniform distribution of the nuclear charge inside the nucleus. The detector-response-convolved spectra are then simulated by the BambooMC package. For 2νββ2\nu\beta\beta and Majoron-emitting ββ\beta\beta spectra, we use the Decay0 package [39] to generate events with momenta of two electrons, and then, simulate the detector response with the BambooMC package as well. The obtained spectra with detector response incorporated are shown in Figure 1. The ROI acceptance for 136Xe^{136}\mathrm{Xe} 2νββ2\nu\beta\beta in the ξ312ν\xi^{2\nu}_{31} fit varies with ξ312ν\xi^{2\nu}_{31}, while the acceptances for Majoron-emitting modes are 100.00% (n=1n = 1), 100.00% (n=2n = 2), 99.99% (n=3n = 3), and 99.95% (n=7n = 7).

Figure 1. Spectra for G02νG^{2\nu}_{0}, G22νG^{2\nu}_{2}, and the Majoron-emitting ββ\beta\beta modes with n=1n=1, 2, 3, and 7, respectively. Detector response model is taken into account.

Background events originate from three primary sources: liquid xenon, the detector material and the stainless steel platform (SSP) material, and solar neutrinos, as summarized in Table II. 124Xe^{124}\mathrm{Xe} and 125I^{125}\mathrm{I} are taken from the measurements reported in Ref. [40]. For 127Xe{}^{127}\mathrm{Xe}, 129mXe{}^{129\mathrm{m}}\mathrm{Xe}, and 131mXe{}^{131\mathrm{m}}\mathrm{Xe} in Run0, we adopt the xenon-evolution analysis from Ref. [32]. In Run1, due to the absence of neutron calibration, the activities of these xenon isotopes are very low, and their time evolution cannot be determined precisely. Therefore, we allow their activities to float in the fit. The activities of 125Xe{}^{125}\mathrm{Xe} and 133Xe{}^{133}\mathrm{Xe} are left free in Run0 and are negligible in Run1. 85Kr{}^{85}\mathrm{Kr} concentration is determined via β\beta-γ\gamma cascade tagging through the isomeric 85mRb{}^{85\mathrm{m}}\mathrm{Rb} [41]. 214Pb{}^{214}\mathrm{Pb} and 212Pb{}^{212}\mathrm{Pb} components are also treated as free parameters. The material of the detector and the SSP contributes to the background. Activities of 232Th{}^{232}\mathrm{Th}, 238U{}^{238}\mathrm{U}, 60Co{}^{60}\mathrm{Co}, and 40K{}^{40}\mathrm{K} in the detector components are taken from measurements using high-purity germanium counting stations [42], while activities of 232Th{}^{232}\mathrm{Th} and 238U{}^{238}\mathrm{U} in SSP components are taken from Ref. [43]. The solar pppp and 7Be{}^{7}\mathrm{Be} neutrino contributions are taken from Refs. [44, 45].

ComponentsExpected2νββ2\nu\beta\betaξ312ν\xi_{31}^{2\nu}Majoron (n=7n = 7)
136Xe^{136}\mathrm{Xe}—54848±136954848 \pm136955424±140055424 \pm140053558±149853558 \pm1498
SSP 232Th^{232}\mathrm{Th}3813±3433813 \pm3433433±2353433 \pm2353439±2273439 \pm2273425±2373425 \pm237
SSP 238U^{238}\mathrm{U}1672±5021672 \pm5021884±3731884 \pm3731683±3841683 \pm3841931±3681931 \pm368
Detector 60Co^{60}\mathrm{Co}3620±18103620 \pm18102671±1632671 \pm1632627±1602627 \pm1602708±1732708 \pm173
Detector 40K^{40}\mathrm{K}3840±16133840 \pm16132918±1162918 \pm1162848±1222848 \pm1222952±1302952 \pm130
Detector 232Th^{232}\mathrm{Th}2942±17952942 \pm17954190±2124190 \pm2124182±2054182 \pm2054193±2334193 \pm233
Detector 238U^{238}\mathrm{U}2288±13962288 \pm13961844±2521844 \pm2521786±2301786 \pm2301869±2451869 \pm245
164 keV (Run0)40984±197840984 \pm197841635±40341635 \pm40341633±38941633 \pm38941627±104341627 \pm1043
208 keV (Run0)3643±1543643 \pm1543858±763858 \pm763854±753854 \pm753846±1103846 \pm110
236 keV (Run0)54799±666054799 \pm666057306±53057306 \pm53057305±51157305 \pm51157301±143657301 \pm1436
380 keV (Run0)2450±1772450 \pm1772408±712408 \pm712405±692405 \pm692409±862409 \pm86
408 keV (Run0)8567±4068567 \pm4069167±1259167 \pm1259162±1249162 \pm1249165±2389165 \pm238
125I^{125}\mathrm{I} (Run0)56±1156 \pm1161±1061 \pm1060±1060 \pm1060±1060 \pm10
125Xe^{125}\mathrm{Xe} (Run0)float565±85565 \pm85569±81569 \pm81552±82552 \pm82
214Pb^{214}\mathrm{Pb} (Run0)float11902±28211902 \pm28211918±27511918 \pm27511664±40311664 \pm403
133Xe^{133}\mathrm{Xe} (Run0)float8566±1808566 \pm1808549±1768549 \pm1768549±2728549 \pm272
212Pb^{212}\mathrm{Pb} (Run0)float1449±2161449 \pm2161407±2011407 \pm2011460±2091460 \pm209
85Kr^{85}\mathrm{Kr} (Run0)469±244469 \pm244678±159678 \pm159659±155659 \pm155688±157688 \pm157
164 keV (Run1)float476±34476 \pm34473±35473 \pm35472±37472 \pm37
236 keV (Run1)float301±33301 \pm33298±35298 \pm35296±36296 \pm36
125I^{125}\mathrm{I} (Run1)10±1110 \pm119±99 \pm99±99 \pm99±99 \pm9
214Pb^{214}\mathrm{Pb} (Run1)float24586±56124586 \pm56124588±55824588 \pm55824389±73924389 \pm739
212Pb^{212}\mathrm{Pb} (Run1)float746±152746 \pm152705±144705 \pm144721±151721 \pm151
85Kr^{85}\mathrm{Kr} (Run1)1461±4361461 \pm4362213±1692213 \pm1692130±1722130 \pm1722179±1732179 \pm173
124Xe^{124}\mathrm{Xe}140±21140 \pm21137±13137 \pm13137±13137 \pm13136±13136 \pm13
pp+7Be νpp+{}^{7}\mathrm{Be}\ \nu196±21196 \pm21205±21205 \pm21205±20205 \pm20204±21204 \pm21

Table II. The background contributions in the ROI for Run0 and Run1. The fitted counts are obtained from the 136Xe 2νββ^{136}\mathrm{Xe}\ 2\nu\beta\beta half-life measurement, the ξ312ν\xi_{31}^{2\nu} measurement, and the Majoron-emitting ββ\beta\beta search with mode n=7n = 7.

Assuming no new physics is observed in this study, a one-dimensional binned likelihood fit is first performed to measure the half-life of 136Xe{}^{136}\mathrm{Xe} 2νββ2\nu\beta\beta, using a Frequentist approach, as shown in Figure 2. The likelihood is constructed as

Figure 2. The SS data spectra and the fit for the 136^{136}Xe 2νββ2\nu\beta\beta half-life are shown for Run0 (top) and Run1 (bottom) from 20 keV to 2800 keV with a bin size of 4 keV. The horizontal axis represents the reconstructed energy in the data. Xe* denotes the contributions from 124^{124}Xe, 125^{125}Xe, 127^{127}Xe, 129m^{129m}Xe, 131m^{131m}Xe, and 133^{133}Xe. Material includes the contributions from SSP 232^{232}Th, SSP 238^{238}U, detector 60^{60}Co, detector 40^{40}K, detector 232^{232}Th, and detector 238^{238}U. The lower panel shows the residuals together with ±1σ\pm1\sigma, ±2σ\pm2\sigma, and ±4σ\pm4\sigma bands.

L=∏r=01∏i=1Nbins(Nr,i)Nr,iobse−Nr,iNr,iobs!G(Mr;Mrin,Σr)∏j=1NGG(ηj;0,σj)(3)L=\prod_{r=0}^{1}\prod_{i=1}^{N_{\mathrm{bins}}}\frac{\left(N_{r,i}\right)^{N^{\mathrm{obs}}_{r,i}}e^{-N_{r,i}}}{N^{\mathrm{obs}}_{r,i}!}G\left(M_r;M_r^{\mathrm{in}},\Sigma_r\right) \prod_{j=1}^{N_G}G\left(\eta_j;0,\sigma_j\right) \tag*{(3)}

where Nr,iN_{r,i} and Nr,iobsN^{\mathrm{obs}}_{r,i} are the expected and observed numbers of events in the iith energy bin for Run-rr, respectively. NiN_i in Run-rr is defined as

Ni=(1+ηa)[(1+ηs)nsSi+∑b=1Nbkg(1+ηb)nbBb,i].(4)N_i=(1+\eta_a)\left[(1+\eta_s)n_sS_i+\sum_{b=1}^{N_{\mathrm{bkg}}}(1+\eta_b)n_bB_{b,i}\right]. \tag*{(4)}

where nsn_s and nbn_b are the counts of signal ss and background component bb, respectively. The corresponding SiS_i and Bb,iB_{b,i} are the iith bin values of the normalized energy spectrum convolved with the five-parameter energy response model. The Gaussian penalty term G(Mr,Mrin,Σr)G(M_r,M_r^{\mathrm{in}},\Sigma_r) of the energy response contains the five-parameter MrinM_r^{\mathrm{in}} and the covariance matrix Σr\Sigma_r in Run-rr. The Gaussian penalty terms G(ηj;0,σj)G(\eta_j;0,\sigma_j) are used to constrain the nuisance parameters ηa\eta_a, ηs\eta_s, and ηb\eta_b, which represent the relative deviations in the overall efficiency, the signal selection, and the background model (see Table II), respectively. The radioactivities of detector and SSP materials, 124Xe{}^{124}\mathrm{Xe} concentrations, and solar pppp and 7Be{}^{7}\mathrm{Be} neutrino fluxes are identical in Run0 and Run1. Other background components are treated independently for Run0 and Run1.

The observed backgrounds are in general agreement with expectations, as shown in Table II. The fitted contributions from 85Kr{}^{85}\mathrm{Kr} in Run1 and SSP 232Th{}^{232}\mathrm{Th} are pulled by 1.8σ1.8\sigma and 1.2σ1.2\sigma, respectively, relative to their input values. The bias of the overall efficiency obtained from the fit is 3.9%±0.6%3.9\%\pm0.6\% (Run0) and −0.4%±1.4%-0.4\%\pm1.4\% (Run1), and the bias of the signal selection is −0.9%±1.9%-0.9\%\pm1.9\% (Run0) and 1.2%±2.1%1.2\%\pm2.1\% (Run1). The half-life of 136Xe{}^{136}\mathrm{Xe} 2νββ2\nu\beta\beta is measured as 2.14±0.052.14\pm0.05 (stat. ++ syst.) ×1021\times10^{21} years, representing the most precise result so far, with a total uncertainty smaller than that of any previous measurement. It is worth noting that this result is slightly smaller than our previous result from Run0 data [12], due to the use of the updated and slightly smaller 136Xe{}^{136}\mathrm{Xe} abundance of 8.584%±0.114%8.584\%\pm0.114\% [43], compared to the previous value of 8.857%±0.168%8.857\%\pm0.168\%. The 136Xe{}^{136}\mathrm{Xe} 2νββ2\nu\beta\beta spectrum is treated as the background in the search for Majoron-emitting ββ\beta\beta signals, as shown later.

In the fit of ξ312ν\xi_{31}^{2\nu}, we allow both the half-life of 136Xe{}^{136}\mathrm{Xe} 2νββ2\nu\beta\beta and ξ312ν\xi_{31}^{2\nu} (i.e., the shape of 136Xe{}^{136}\mathrm{Xe} 2νββ2\nu\beta\beta) to float freely. The likelihood is almost the same as Eq. (3), but with a different definition of NiN_i in Run-rr, which is modified as

Ni=(1+ηa)[(1+ηs)nsSi,G0+ξSi,G21+ξ+∑b=1Nbkg(1+ηb)nbBb,i].(5)N_i=(1+\eta_a)\left[(1+\eta_s)n_s\frac{S_{i,\mathrm{G0}}+\xi S_{i,\mathrm{G2}}}{1+\xi}+\sum_{b=1}^{N_{\mathrm{bkg}}}(1+\eta_b)n_bB_{b,i}\right]. \tag*{(5)}

where Si,G0S_{i,\mathrm{G0}} and Si,G2S_{i,\mathrm{G2}} denote the normalized energy spectrum values in the iith bin for the first and second terms of the Taylor expansion of the 2νββ2\nu\beta\beta decay rate, respectively. The parameter ξ\xi is defined as ξ=G22νG02νϵ312νϵ312ν\xi=\frac{G^{2\nu}_{2}}{G^{2\nu}_{0}}\frac{\epsilon^{2\nu}_{31}}{\epsilon^{2\nu}_{31}}, where

ϵ0\epsilon_0 and ϵ2\epsilon_2 denote the total detection efficiencies for the theoretical spectra of the first and second terms of the Taylor expansion, respectively. The rest of the parameters remain the same as in Eq. (4).

The backgrounds, also summarized in Table II, are consistent with expectations, except for the contributions from 85Kr^{85}\mathrm{Kr} in Run1 and SSP 232Th^{232}\mathrm{Th}, which have pulls of 1.6σ1.6\sigma and 1.2σ1.2\sigma, respectively. The bias of the overall efficiency obtained from the fit is 3.7%±0.6%3.7\% \pm0.6\% (Run0) and −0.7%±1.4%-0.7\% \pm1.4\% (Run1), and the bias of the signal selection is −0.9%±1.9%-0.9\% \pm1.9\% (Run0) and 1.3%±2.1%1.3\% \pm2.1\% (Run1). We obtained a best fit of ξ312ν=0.59−0.38+0.41\xi_{31}^{2\nu} = 0.59^{+0.41}_{-0.38}.

Figure 3 compares the measured values of ξ312ν\xi_{31}^{2\nu} and the 136Xe 2νββ^{136}\mathrm{Xe}\ 2\nu\beta\beta half-life obtained by KamLAND-Zen [10] and by this work. Although both results are consistent with ξ312ν=0\xi_{31}^{2\nu} = 0, our measured value has the opposite sign to that reported by KamLAND-Zen (−0.26−0.25+0.31-0.26^{+0.31}_{-0.25}). Assuming fully uncorrelated uncertainties, the two measurements differ by approximately 1.7σ1.7\sigma.

Figure 3. Comparison of 136^{136}Xe 2νββ2\nu\beta\beta half-lives and ξ312ν\xi^{2\nu}_{31} values from the KamLAND-Zen experiment [10] and our present analysis. The gray dashed line indicates the zero ξ312ν\xi^{2\nu}_{31}.

Our result is consistent with quasiparticle random-phase approximation predictions [10] at the 1σ1\sigma level and remains compatible with shell-model calculations [10] within 2σ2\sigma. However, the current precision does not allow us to exclude ξ312ν=0\xi_{31}^{2\nu} = 0 conclusively and prevents us from discriminating between the higher-state dominance and single-state dominance hypotheses [22]. Achieving such discrimination will require improved precision in future experiments.

The inclusion of the second-order contribution is found to have a negligible impact on the extracted 136Xe 2νββ^{136}\mathrm{Xe}\ 2\nu\beta\beta decay rate. The corresponding half-life is determined to be 2.11±0.052.11 \pm0.05 (stat. + syst.) ×1021\times10^{21} years, which is consistent with the result obtained from a 136Xe 2νββ^{136}\mathrm{Xe}\ 2\nu\beta\beta-only fit that neglects the second-order contribution.

In the fit of Majoron-emitting ββ\beta\beta, the likelihood is similar to Eq. (3), except that 136^{136}Xe 2νββ2\nu\beta\beta is moved from the signal term to the background term, and then, Majoron-emitting ββ\beta\beta is introduced as the signal. As an example, the best-fit spectrum for mode n=7n = 7 is shown in Figure 4. No statistically significant evidence for Majoron-emitting ββ\beta\beta decays is observed for any mode considered here, and the lower limits on Majoron-emitting ββ\beta\beta half-lives are derived at the 90% confidence level (CL), as summarized in Table III. The extension of the lower bound of the ROI from 600 keV (as in EXO-200 [29]) to 20 keV considerably improves the sensitivity to mode n=7n = 7, where the Majoron-emitting ββ\beta\beta spectrum peaks at approximately 600 keV, leading to the most stringent constraint. However, our sensitivity to modes n=1n = 1, 2, and 3 is limited due to our 136^{136}Xe exposure being only 0.16 times that of EXO-200 [29] and our higher background level. Similarly, the backgrounds are consistent with expectations, with only the contributions from 85^{85}Kr in Run1 and SSP 232^{232}Th pulled by 1.7σ1.7\sigma and 1.2σ1.2\sigma, respectively (Table II). The bias of the overall efficiency obtained from the fit is 2.6% ±\pm 1.8% (Run0) and −0.6%±1.8%-0.6\% \pm1.8\% (Run1), and the bias of the signal selection is −0.1%±2.1%-0.1\% \pm2.1\% (Run0) and 0.0%±2.4%0.0\% \pm2.4\% (Run1).

Figure 4. Spectra fits with Majoron-emitting ββ\beta\beta decay signals (n=7n = 7) for Run0 (top) and Run1 (bottom), respectively. The figures are similar to Figure 2 but with the upper limit (90% CL) on the Majoron-emitting ββ\beta\beta signal (mode n=7n = 7) illustrated as hatched histograms. The lower panel shows the residuals together with ±1σ\pm1\sigma, ±2σ\pm2\sigma, and ±4σ\pm4\sigma bands.

Decay modeThis work (yr)EXO-200 (2021) (yr)
n=1n = 1>2.4×1023>2.4 \times10^{23}>4.3×1024>4.3 \times10^{24}
n=2n = 2>1.2×1023>1.2 \times10^{23}>1.5×1024>1.5 \times10^{24}
n=3n = 3>5.7×1022>5.7 \times10^{22}>6.3×1023>6.3 \times10^{23}
n=7n = 7>7.0×1022>7.0 \times10^{22}>5.1×1022>5.1 \times10^{22}

Table III. The 90% CL lower limits on half-lives for different Majoron-emitting ββ\beta\beta decay models and the comparison with EXO-200 results [29]

In summary, we perform a measurement of ξ312ν\xi^{2\nu}_{31} in 2νββ2\nu\beta\beta and a search for Majoron-emitting ββ\beta\beta for 136Xe{}^{136}\mathrm{Xe} with a total 136Xe{}^{136}\mathrm{Xe} exposure of 39.1±0.739.1 \pm0.7 kg·yr using PandaX-4T data. The most precise measurement of the 136Xe{}^{136}\mathrm{Xe} 2νββ2\nu\beta\beta half-life to date is achieved thanks to the nearly complete spectrum used in the fit. Our measurement of ξ312ν\xi^{2\nu}_{31} is consistent with theoretical predictions. The ξ312ν\xi^{2\nu}_{31} values from KamLAND-Zen and this work are broadly consistent, with a modest (∼1.7σ\sim1.7\sigma) difference. The most competitive results for the Majoron-emitting ββ\beta\beta mode with n=7n = 7 are obtained. Following detector upgrades in 2023, PandaX-4T has been taking data in the second science run (Run2). The capability to reconstruct the nearly complete 136Xe ββ{}^{136}\mathrm{Xe}\ \beta\beta spectrum will allow us to fully exploit the PandaX-4T dataset, significantly enhancing its physics potential.

**Acknowledgements—**This project is supported in part by grants from the National Key R&D Program of China (No. 2023YFA1606200 and No. 2023YFA1606202), National Science Foundation of China (No. 12090060, No. 12090062, No. 12305121, No. U23B2070), and by Office of Science and Technology, Shanghai Municipal Government (Grants No. 21TQ1400218, No. 22JC1410100, No. 23JC1410200, No. ZJ2023-ZD-003). We are grateful for the support of the Fundamental Research Funds for the Central Universities. We also thank for their sponsorship: the Chinese Academy of Sciences Center for Excellence in Particle Physics (CCEPP), Thomas and Linda Lau Family Foundation, New Cornerstone Science Foundation, Tencent Foundation in China, and Yangyang Development Fund. Finally, we thank the CJPL administration and the Yalong River Hydropower Development Company Ltd. for indispensable logistical support and other help.

**Data availability—**The data that support the findings of this article are not publicly available upon publication because it is not technically feasible and/or the cost of preparing, depositing, and hosting the data would be prohibitive within the terms of this research project. The data are available from the authors upon reasonable request.

References

References

  1. [1]M. Goeppert-Mayer, Phys. Rev. 48, 512 (1935).
  2. [2]W. H. Furry, Phys. Rev. 56, 1184 (1939).
  3. [3]J. Schechter and J. W. F. Valle, Phys. Rev. D 25, 2951 (1982).
  4. [4]M. Agostini et al., Rev. Mod. Phys. 95, 025002 (2023).
  5. [5]J. J. Gómez-Cadenas et al., Riv. Nuovo Cimento 46, 619 (2023).
  6. [6]Y. Chikashige, R. Mohapatra, and R. Peccei, Phys. Lett. 98B, 265 (1981).
  7. [7]G. Gelmini and M. Roncadelli, Phys. Lett. 99B, 411 (1981).
  8. [8]H. M. Georgi, S. L. Glashow, and S. Nussinov, Nucl. Phys. B193, 297 (1981).
  9. [9]J. B. Albert et al. (EXO Collaboration), Phys. Rev. C 89, 015502 (2014).
  10. [10]A. Gando et al. (KamLAND-Zen Collaboration), Phys. Rev. Lett. 122, 192501 (2019).
  11. [11]P. Novella et al. (NEXT Collaboration), Phys. Rev. C 105, 055501 (2022).
  12. [12]L. Si et al. (PandaX Collaboration), Research 2022, 9798721 (2022).
  13. [13]S. Abe et al. (KamLAND-Zen Collaboration), Phys. Rev. Lett. 135, 262501 (2025).
  14. [14]G. Anton et al. (EXO-200 Collaboration), Phys. Rev. Lett. 123, 161802 (2019).
  15. [15]M. Agostini et al. (GERDA Collaboration), Phys. Rev. Lett. 125, 255202 (2020).
  16. [16]I. J. Arnquist et al. (Majorana Collaboration), Phys. Rev. Lett. 130, 062501 (2023).
  17. [17]B.-T. Zhang et al., Chin. Phys. C 48, 103001 (2024).
  18. [18]H. Acharya et al. (LEGEND Collaboration), Phys. Rev. Lett. 136, 022701 (2026).
  19. [19]D. Q. Adams et al. (CUORE Collaboration), Science 390, 1029 (2025).
  20. [20]J. Engel and J. Menéndez, Rep. Prog. Phys. 80, 046301 (2017).
  21. [21]S. Dell’Oro et al., Adv. High Energy Phys. 2016, 2162659 (2016).
  22. [22]F. Šimkovic et al., Phys. Rev. C 97, 034315 (2018).
  23. [23]M. LattanzI and J. W. F. Valle, Phys. Rev. Lett. 99, 121301 (2007).
  24. [24]F. Bazzocchi et al., J. Cosmol. Astropart. Phys. (2008), 013.
  25. [25]M. Lattanzi et al., Phys. Rev. D 88, 063528 (2013).
  26. [26]M. Hirsch et al., Phys. Lett. B 372, 8 (1996).
  27. [27]R. Mohapatra, A. Pérez-Lorenzana, and C. de S. Pires, Phys. Lett. B 491, 143 (2000).
  28. [28]A. Gando et al. (KamLAND-Zen Collaboration), Phys. Rev. C 86, 021601 (2012).
  29. [29]S. Al Kharusi et al., Phys. Rev. D 104, 112002 (2021).
  30. [30]S. Zhang et al., Sci. Bull. 70, 1779 (2025).
  31. [31]Z. Bo et al. (PandaX Collaboration), Phys. Rev. Lett. 134, 011805 (2025).
  32. [32]T. Li et al. (PandaX Collaboration), Phys. Rev. Lett. 134, 071004 (2025).
  33. [33]Y. Meng et al. (PandaX Collaboration), Phys. Rev. Lett. 127, 261802 (2021).
  34. [34]Y. Luo et al. (PandaX Collaboration), Phys. Rev. D 110, 023029 (2024).
  35. [35]X. Yan et al. (PandaX Collaboration), Phys. Rev. Lett. 132, 152502 (2024).
  36. [36]X. Chen et al., J. Instrum. 16 (2021), T09004.
  37. [37]D. C. v. Šefčák et al., Phys. Rev. C 92, 055502 (2015).
  38. [38]F. Salvat, J. Fernández-Varea, and W. Williamson, Comput. Phys. Commun. 90, 151 (1995).
  39. [39]O. A. Ponkratenko, V. I. Tretyak, and Y. G. Zdesenko, Phys. At. Nucl. 63, 1282 (2000).
  40. [40]Z. Bo et al., J. High Energy Phys. 05 (2025), 119.
  41. [41]P. Collon, W. Kutschera, and Z.-T. Lu, Annu. Rev. Nucl. Part. Sci. 54, 39 (2004).
  42. [42]Z. Qian et al. (PandaX Collaboration), J. High Energy Phys. 06 (2022), 147.
  43. [43]L. Luo et al., J. High Energy Phys. 05 (2025), 089.
  44. [44]J.-W. Chen et al., Phys. Lett. B 774, 656 (2017).
  45. [45]G. Bellini et al. (BOREXINO Collaboration), Nature (London) 512, 383 (2014).

Paper details

vlnc:W_k7tqjuuw
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 9

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents